March 18, 2019
Shannon V. Becker
Aqua North Carolina, Inc.
202 Mackenan Court
Cary, NC 27511
Subject: Compliance Evaluation Inspection Report V +C
Spring Creek WWTP MAR
NPDES Permit NCO083925 and Collection System WQCSDO195 AR 2 % 2019
Davidson County water `y
i'Qrmil.e °arcs;,
Dear Mr. Becker: 1�g section
On February 21, 2019, Paul DiMatteo and Jenny Graznak of the Division of Water Resources (Division), Winston-
Salem Regional Office met with Charles Pearson, Operator in Responsible Charge (ORC) to conduct Compliance
Evaluation Inspections of the above referenced wastewater treatment systems. This inspection consists of a review of the
permit and accompanying documentation to determine compliance with permit conditions, and an on -site inspection of
several collection system components. The attached inspection form notes the areas that were evaluated for the inspection,
with notable findings outlined as follows.
1. The inspector noted a concern with the amount of air gap under the effluent weir's nappe due to the relatively
high water level in the downstream basin. If submerged flow becomes apparent, appropriate steps should be taken to ensure
accurate readings.
2. Two manholes were inspected: one just outside the wastewater treatment plant, and one near Twin Valley
Drive & Twin Valley Court. The latter manhole had a buildup of debris. Mr. Pearson said he recently had someone flush
this line, and that we would have them come out again.
The inspections were considered compliant. If you have any questions concerning this report please contact Paul
DiMatteo at (336) 776-9694 or Lon Snider at (336) 776-9800.
Sincerely,
DocuSigned by.
SMxv
145B49E225C94EA...
Lon T. Snider, Assistant Regional Supervisor
Water Quality Regional Operations Section
Winston-Salem Regional Office
Division of Water Resources, NCDEQ
Enclosures — Inspection Report (x2)
CC: WQS Winston-Salem Regional Office
PERC-,-bJirir Q
Central Files
D. E Q North Carolina Department of Environmental Quality I Division of Water Resources
50 Winston-Salem Regional Office 1 450 Hanes MITI Road Sulte 3001 Winston-Salem, North Carolina 27103
n�anacaaaiiNa �'
°"""�'�' °d��� 336.776.9800
United States Environmental Protection Agency
Form Approved.
EPA Washington, D.C. 20460
OMB No. 2040-0057
Water Compliance Inspection Report
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1. IN 1 2 15 I 3 I NCO083941 I11 12 19/02/21 17 18 [� j 19 I G I 201
21111111IIIIIII.IIIIIIIIIIIIIIIIII IIIIIIIIIII i66
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA — -Reserved ' —
67 70 I j 71 L] 72 �LJ , � 731 I 174 751 I I I I I .I I80
LJ
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES Permit Number)
11:00AM 19/02/21
14/06/01
Spring Creek WWTP
Exit Time/Date
Permit Expiration Date
292 Central Rd
Winston Salem NC 27102
12:30PM 19/02/21
19/05/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
Other Facility Data
Charles Alton Pearson/ORC//
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Joseph R Pearce,202 Mackenan Crt Cary NC 27511/Director of
No
Operations/919-653-6964/9194601788
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenance Records/Reports
Self -Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters
Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Jennifer F Graznak oocusigned by: WSRO WQ//336-771-5000/
3/18/2019
Paul DiMatteo �� WSRO WQ//336-776-9691/
F10C7C2E5BB3404...
Signature of Management Q'A Reviewer stgned by: Agency/Office/Phone and Fax Numbers Date
FL:-C-,.
T 5mAr, 3/18/19
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page#
NPDES yr/mo/day Inspection Type (Cont.)
31 NCO083941 I11 121 19/02/21 117 18 ICI
Section D: Summary of Finding/Comments (Attach additional sheets -of narrative and checklists as necessary)
I initially met with Mr. Pearson on 1/30/2019 to get a brief overview of the plant and observe his sample
collection practices. Jenny Graznak and I then slid a more thorough inspection on 2/21.
Sludge hauling by Forsyth Rooter Service, taken to Archie Elledge
11/30/2018 08,000 gal
05/25/2018 12,000 gal
11/28/2017 12,000 gal
11/28/2017 12,000 gal
11/21/2017 06,400 gal
05/26/2017 16,000 gal
04/15/2016 19,200 gal
Concern with flow measurement - there was not much of an air gap between the bottom of the weir
crest and the downstream water level. This should be monitored. If submerged flow is apparent then
appropriate action should be taken to ensure accurate readings. If possible, the downstream water
level should be lowered.
Page#
Permit: NCO083941 Owner -Facility: SpringCreekWWTP
Inspection Date: 02/21/2019 Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable 0 ❑ ❑ ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment: Mr. Pearson said his primary process control test was Sludge Volume Index (SVI)
Permit
Yes No NA NE
(if the present permit expires in 6 months or less). Has the permittee submitted a new
0
El .
❑
❑
application?
Is the facility as described in the permit?
0
❑
❑
❑
# Are there any special conditions for the permit?
❑
0
❑
❑
Is access to the plant site restricted to the general public?
N
❑
❑
❑
Is the inspector granted access to all areas for inspection?
N
❑
❑
❑
Comment:
Bar Screens
Yes No NA NE
Type of bar screen
a.Manual
b.Mechanical
❑
Are the bars adequately screening debris?
0
❑
❑
❑
Is the screen free of excessive debris?
❑
❑
❑
Is disposal of screening in compliance?
0
❑
❑
❑
Is the unit in good condition?
M
❑
❑
❑
Comment:
Equalization Basins
Yes' No NA NE
Is the basin aerated?
❑
0
❑
❑
Is the basin free of bypass lines or structures to the natural environment?
0
❑
❑
❑
Is the basin free of excessive grease?
0
❑
❑
❑
Are all pumps present?
0
❑
❑
❑
Are all pumps operable?
0
❑
❑
❑
Are float controls operable?.
❑
❑
0
❑
Are audible and visual alarms operable?
❑
❑
M
❑
# Is basin size/volume adequate?
❑
❑
❑
Page# 3
i
Permit: NCO083941 Owner - Facility: Spring Creek WWTP
Inspection Date: 02/21/2019 Inspection Type: Compliance Evaluation
Equalization Basins
Yes No NA NE
Comment: Mr. Pearson said he recently got some blowers and diffusers to aerate the EQ basin.
Aeration Basins
Mode of operation
Type of aeration system
Is the basin free of dead spots?
Are surface aerators and mixers operational?
Are the diffusers operational?
Is the foam the proper color for the treatment process?
Does the foam cover less than 25% of the basin's surface?
Is the DO level acceptable?
Is the DO level acceptable?(1.0 to 3.0 mg/1)
Comment:
Secondary Clarifier
Is the clarifier free of black and odorous wastewater?
Is the site free of excessive buildup of solids in center well of circular clarifier?
Are weirs level?
Is the site free of weir blockage?
Is the site free of evidence of short-circuiting?
Is scum removal adequate?
Is the site free of excessive floating sludge?
Is the drive unit operational?
Is the return rate acceptable (low turbulence)?
Is the overflow clear of excessive solids/pin floc?
Is the sludge blanket level acceptable? (Approximately %4 of the sidewall depth)
Comment: There was approx. 5 feet of sludge in the clarifier.
Disinfection - UV
Are extra UV bulbs available on site?
Are UV bulbs clean?
Is UV intensity adequate?
Is transmittance at or above designed level?
Yes No NA NE
Ext. Air
Diffused
■
❑
❑
❑
❑
❑
■
❑
,E
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
❑
❑
❑
■
❑
❑
❑
E
Yes No NA NE-
❑
❑
N
❑
❑
❑
■
❑
■
❑
❑
❑
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
❑
❑
❑
❑
❑
❑
■
❑
❑
❑
E
❑
❑
❑
Yes No NA NE
■ ❑ ❑ ❑
■ ❑ ❑ ❑
❑ ❑ ❑ N
❑ ❑ ❑
Page# 4
Permit: NCO083941 Owner - Facility: Spring Creek WWTP
Inspection Date: 02121/2019 Inspection Type: Compliance Evaluation
Disinfection - UV Yes No NA NE
'Is there a backup system on site? M ❑ ❑ ❑
Is effluent clear and free of solids? 0 ❑ ❑ ❑
Comment: 8 bulbs.
Aerobic Digester
Yes No NA NE
Is the capacity adequate?
0
❑
❑
❑
Is the mixing adequate?
0
❑
❑
❑
Is the site free of excessive foaming in the tank?
0
❑
❑
❑
# Is the odor acceptable?
❑
❑
❑
# Is tankage available for properly waste sludge?
❑
❑
❑
0
Comment:
Flow Measurement - Effluent
Yes No NA NE
# Is flow meter used for reporting?
N
❑
❑
❑
Is flow meter calibrated annually?
N
❑
❑
❑
Is the flow meter operational?
M
❑
❑
❑
(If units are separated) Does the chart recorder match the flow meter?
❑
❑
0
❑
Comment: Bubbler flow meter on"90 degree weir. The level just beyond the weir• was such that there
was little space for an air gap.
Standby Power
Yes No NA NE
Is automatically activated standby power available?
M
❑
❑
❑
Is the generator tested by interrupting primary power source?
M
❑
❑
❑
Is the generator tested under load?
M
❑
❑
❑
Was generator tested & operational during the inspection?
M
❑
❑
❑
Do the generator(s) have adequate capacity to operate the entire wastewater site?
0
❑
❑
❑
Is there an emergency agreement with a fuel vendor for extended run on back-up power?
M
❑
❑
❑
Is the generator fuel level monitored?
0
❑
❑
❑
Comment:
Laboratory Yes No NA NE
Are field parameters performed by certified personnel or laboratory? 0 ❑ ❑ ❑
Are all other parameters(excluding field parameters) performed by a certified lab? 0 ❑ ❑ ❑
# Is the facility using a contract lab? N ❑ ❑ ❑
Page# 5
Permit: NCO083941 Owner -Facility: Spring Creek WWTP
Inspection Date: 02/21/2019 Inspection Type: Compliance- Evaluation
Laboratory Yes No NA NE
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees r ❑ ❑ ❑
Celsius)?
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? ❑ ❑ ❑
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? ❑ ❑ ❑
Comment:
Effluent Sampling
Yes No NA NE
Is composite sampling flow proportional?
N
❑
❑
❑
Is sample collected below all treatment units?
N
❑
❑
❑
Is proper volume collected?
0
❑
❑
❑
Is the tubing clean?
0
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
E
❑
❑
❑
Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
❑
❑
❑
representative)?
Comment: Sampler was set to take 100 ml every 7 pulses, with 1 pulse = 50 qallons and no max. Mr.
Pearson said on average it fills the sample mug halfway.
Effluent Pipe
Yes No NA NE
Is right of way to the outfall properly maintained?
0
❑
❑
❑
Are the receiving water free of foam other than trace amounts and other debris?
❑
❑
❑
If effluent (diffuser pipes are required) are they operating properly?
❑
❑
E
❑
Comment:
Record Keeping
Are records kept and maintained as required by the permit?
Is all required information readily available, complete and current?
Are all records maintained for 3 years (lab. reg. required 5 years)?
Are analytical results consistent with data reported on DMRs?
Is the chain -of -custody complete?
Dates, times and location of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Yes No NA NE
❑ ❑ ❑
❑ ❑ ❑
■ ❑ ❑ ❑
❑ ❑ ❑
E ❑ ❑ ❑
Page# 6
Permit: NCO083941 Owner - Facility: Spring Creek WWTP
Inspection Date: 02/21/2019 Inspection Type: Compliance Evaluation
Record Keeping
Yes No NA NE
Transported COCs
Are DMRs complete: do they include all permit parameters?
0
❑
❑
❑
Has the facility submitted its annual compliance report to users and DWQ?
0
❑
❑
❑
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator
❑
0
0
❑
on each shift?
Is the ORC visitation log available and current?
M
❑
❑
❑
Is the ORC certified at grade equal to or higher than the facility classification?
0
❑
❑
❑
Is the backup operator certified at one grade less or greater than the facility classification?
❑
❑
❑
Is a copy of the current NPDES permit available on site?
❑
❑
❑
Facility has copy of previous year's Annual Report on file for review?
❑
❑
❑
Comment:
Page# 7
Compliance Insoection Reoort
Permit: WQCSD0195 Effective: 03/01/00 Expiration:, Owner: Aqua North Carolina Inc
SOC: Effective: Expiration: Facility: Spring Creek Subdivision Collection System
County: Davidson
Region: Winston-Salem
Contact Person: Joseph R Pearce Title: Director of Operations Phone: 919-653-6964
Directions to Facility:
System Classifications:
Primary ORC:
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Inspection Date: 02/21/2019
Primary inspector: Paul DiMatteo
Secondary Inspector(s):
Certification:
Phone:
Entry Time: 12:30PM Exit Time: 01:OOPM
Phone: 336-776-9691
Reason for Inspection: Routine Inspection Type: Collection System Inspect Non Sampling
Permit Inspection Type: Deemed permitted collection system management and operation
Facility Status: Compliant Not Compliant
Question Areas:
Miscellaneous Questions Operation & Maint Reqmts Records
Inspections Manhole
(See attachment summary)
Page 1 of 5
Permit: WQCSD0195 Owner- Facility: Aqua North Carolina Inc
Inspection Date: 02/21/2019 Inspection Type :.Collection System Inspect Non Sampling Reason for Visit: Routine
Inspection Summary:
Page 2 of 5
Permit: WQCSDO195 Owner- Facility: Aqua North Carolina Inc
Inspection Date: 02/21/2019 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine
Inspections
Yes No NA NE
Are maintenance records for sewer lines available?
❑ ❑ ❑
Are records available that document pump station inspections?
❑
❑ ❑
Are SCADA or telemetry equipped pump stations inspected at least once a week?
❑
❑ 0 ❑
Are non-SCADA/telemetry equipped pump stations inspected every day?
❑
❑ ❑
Are records available that document citizen complaints?
❑
❑ 0 ❑
# Do you have a system to conduct an annual observation of entire system?
❑ ❑ ❑
# Has there been an observation of remote areas in the last year?
❑ ❑ ❑
Are records available that document inspections of high -priority lines?
❑
❑ 0 ❑
Has there been visual inspections of high -priority lines in last six months?
❑
❑ M ❑
Comment: System is all gravity with no high priority lines.
Operation & Maintenance Requirements Yes No NA NE
Are all log books available? M ❑ ❑ ❑
Does supervisor review all log books on a regular basis? ❑ ❑ ❑
Does the supervisor have plans to address documented short-term problem areas? ❑ ❑ ❑
What is the schedule for reviewing inspection, maintenance, & operations logs and problem areas?
Are maintenance records for equipment available? ❑ ❑ M ❑
Is a schedule maintained for testing emergency/standby equipment? ❑ ❑ M ❑
What is the schedule for testing emergency/standby equipment?
Do pump station logs include
Inside and outside cleaning and debris removal?
❑ ❑ M ❑
Inspecting and exercising all valves?
❑ ❑ M ❑
Inspecting and lubricating pumps and other equipment?
❑ ❑ ❑
Inspecting alarms, telemetry and auxiliary equipment?
❑ ❑ M ❑
Is there at least one spare pump for each pump station w/o pump reliability?
❑ ❑ M ❑
Are maintenance records for right-of-ways available?
❑ ❑ ❑
Are right-of-ways currently accessible in the event of an emergency?
❑ ❑ ❑
Are system cleaning records available?
M ❑ ❑ ❑
Has at least 10% of system been cleaned annually?
❑ ❑ ❑
What areas are scheduled for cleaning in the next 12 months?
Is a Spill Response Action Plan available?
❑ ❑ ❑
Does the plan include:
24-hour contact numbers
❑ ❑ ❑
Response time
M ❑ ❑ ❑
Equipment list and spare parts inventory
M. ❑ ❑ ❑
Page 3 of 5
Permit: WQCSDO195 Owner- Facility: Aqua North Carolina Inc
Inspection Date: 02/21/2019 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine
Access to cleaning equipment
Access to construction crews, contractors, and/or engineers
Source of emergency funds `
Site sanitation and cleanup materials
Post-overflow/spill assessment
Is a Spill Response Action Plan available for all personnel?
Is the spare parts inventory adequate?
Comment:
Records
Are adequate records of all SSOs, spills and complaints available?
Are records of SSOs that are under the reportable threshold available?
Do spill records indicate repeated overflows (2 or more in 12 months) at same location?
If yes, is there a corrective action plan?
Is a map of the system available?
Does the map include:
Pipe sizes
Pipe materials
Pipe location
Flow direction
Approximate pipe age
Number of service taps .
Pump stations and capacity
If no, what percent is complete?
List any modifications and'extensions that need to be added to the map
# Does the permittee have a copy of their permit?
Comment:
UNKNOWN - End of Twin V
Manhole
Is manhole accessible?
# Is manhole cover/vent above grade?
Is the manhole free of visible signs of overflow?
Is the manhole free of sinkholes and depressions?
Is manhole cover present?
# Is manhole properly seated?
# Is manhole in good condition?
# Is invert in good condition?
M ❑ ❑ ❑
❑ ❑ ❑
■❑❑❑
■,❑ El
■❑❑❑
❑ ❑ ❑
Yes No NA NE
❑ ❑ M ❑
❑ ❑ M ❑
❑❑■❑
❑ ❑ N ❑
■❑❑❑
-- ❑❑■❑
❑❑■❑
❑ ❑ ❑
❑' ❑ ❑
❑ ❑ ❑
❑ ❑ ❑
❑❑■❑
❑ ❑ M ❑
Yes No NA NE
❑ ❑ ❑
❑ M ❑ ❑
❑ ❑ ❑
❑ ❑ ❑
M ❑ ❑ ❑
❑ ❑ ❑
Page 4 of 5
Permit: WQCSDO195 Owner -Facility: Aqua North Carolina Inc
Inspection Date: 02/21/2019 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine
Is line free -flowing and unrestricted in manhole? 0 ❑ ❑ ❑
Is manhole free of excessive amounts of grease? N ❑ ❑ ❑
Is manhole free of excessive roots? 0 ❑ ❑ ❑
Is manhole free of excessive sand? E ❑ ❑ ❑
Is manhole's extended vent screened? ❑ ❑ N ❑
Are vents free of submergence? ❑ ❑ ❑
Are manholes free of bypass structures' or pipes? 0 ❑ ❑ ❑
Comment:
UNKNOWN - Near Twin Val
Manhole
Yes No NA NE
Is manhole accessible?
0 ❑ ❑ ❑
# Is manhole cover/vent above grade?
❑ ❑ 0 ❑
Is the manhole free of visible signs of overflow?
0 ❑ ❑ ❑
Is the manhole free of sinkholes and depressions?
0 ❑ ❑ ❑
Is manhole cover present?
0 ❑ ❑ ❑
# Is manhole properly seated?
N ❑ ❑ ❑
# Is manhole in good condition?
0 ❑ ❑ ❑
# Is invert in good condition?
0 ❑ ❑ ❑
Is line free -flowing and unrestricted in manhole?
❑ E ❑ ❑
Is manhole free of excessive amounts of grease?
M ❑ ❑ ❑
Is manhole free of excessive roots?
0 ❑ ❑ ❑
Is manhole free of excessive sand?
M ❑ ❑ ❑
Is manhole's extended vent screened?
❑ ❑ N ❑
Are vents free of submergence?
❑ ❑ E ❑
Are manholes free of bypass structures or pipes?
0 ❑ ❑ ❑
Comment: Manhole had some buildup of flushable wipes. ORC said he just had someone out to clean the
lines and that he would call them out again.
Page 5 of 5