Loading...
HomeMy WebLinkAboutWQ0040708_Compaction Testing_20190412ECS Southeast, LLP 6714 Netherlands Drive Wilmington, NC 28405 (910) 686-9114 [Phone] (910) 686-9666 [Fax] April 11, 2019 Heath Grading & Utility 5080 Edinborough Lane Wilmington, NC 28409 ATTN: Jordan Williamson LETTER OF TRANSMITTAL RE: Old Military Sewer Extension ECS Job # 22:27779 Permits: Location: 6005 Old Military Road WILMINGTON„ NC We are enclosing: X Field Reports X For your use X As requested CC: Heath Grading & Utility - Ray Heath ENCL: Field Report # 4 04/11/2019 2L Kris J. Stamm Office Manager, Principal Disclaimer 1 Darrell J. Henderson, E.I.T. Construction Materials Project Manager 1. This report (and any attachments) shall not be reproduced except in full without prior written approval of ECS. 2. The information in this report relates only to the activities performed on the report date. 3. Where appropriate, this report includes statements as to compliance with applicable project drawings and specifications for the activities performed on this report date. 4. Incomplete or non -conforming work will be recorded for future resolution. 5. The results of samples and/or specimens obtained or prepared for subsequent laboratory testing will be presented in separate reports/documents. 1000.1 Transmittal Page 1/4 ECS Southeast, LLP RG6714 Netherlands Drive Wilmington, NC 28405 (910) 686-9114 [Phone] (910) 686-9666 [Fax] Project Old Military Sewer Extension Location WILMINGTON„ NC Client Heath Grading & Utility - Jordan Williamson Contractor Heath Grading & Utility - Jordan Williamson Remarks Trip Charges* Tolls/Parking Mileage* Chargeable Items 1 -Nuclear Gauge Rental FIELD REPORT Project No. 22:27779 Report No. 4 Day & Date Thursday 04/11/2019 Weather 61°/ Sunny On -Site Time 3.00 Lab Time 0.50 Travel Time* 0.50 Total 4.00 Re Obs.Time 0.00 10 Time of Arrival Departure 08:30A 11:30A * Travel time and mileage will be billed in accordance with the contract. Summary of Services Performed (field test data, locations, elevations & depths are estimates) & Individuals Contacted. The undersigned arrived on site, as requested, to re -check the compaction of soils for the sewer backfill. Please see the attached sketch for the approximate density test locations. Utilizing the Nuclear Density Gauge test method (ASTM D-6938) to check the compaction of soils; test results indicated that the compacted material, at the areas and depths tested, met 98% of the maximum dry density as obtained in our laboratory using the Standard Proctor method (ASTM D-698). By Harold Sherman, — Field Technician Transmittal Page 2/4 1700 1136412 PROJECT: 0(d SHEET NO: 16,6173 TITLE: PROJ. NO: 17 ,? SCALE: /Z'fv BY: DATE: APPROVED: DATE: I I i f I I I I i i I cr /-cot +Wr i I 1 Transmittal Page 3/4 C ECS SOUTHEAST, LLP Field Compaction Summary, ASTM D-6938 Project No: 27779 Project Name: Old Military Sewer Extension Client: Heath Grading & Utility Contractor: Heath Grading & Utility Technician: Harold Sherman Test Method ASTM D-6938 Nuclear Gauge No.3 Make Troxler Density Std 1650 Model 3440 Moisture Std 715 Ser. No. 15896 Page 1 Date: 04/11 /2019 Sample No. Description Proctor Method Uncorrected Max. Densit Uncorrected Opt. MC S-1 Light Brown, Fine to Medium Sand Standard Proctor Method (ASTM D-698) 104.10 14.60 S-2 ABC Stone Modified Proctor Method (ASTM D-1557) 139.10 6.50 Test No. Lot No. Test Mode Probe Depth (in.) Station / Location Lift / Elev Sample No. p % Oversize Corrected Maximum Dry Density (Pcf) Corrected O P Optimum Moisture Content (%) P / F Comments Wet Density (pcf) Dry Density (pcf) Moisture Content Percent Comp. 1 DT 4 sewer backfill sg S-2 0.00 139.10 6.50 141.8 138.8 2.2 99.8 P 2 DT 4 sewer backfill sg S-2 0.00 139.10 6.50 141.7 139.2 1.8 100.1 P 3 DT 4 sewer backfill sg S-2 0.00 139.10 6.50 139.0 136.5 1.8 98.1 P 4 DT 6 sewer backfill -1 S-1 0.00 104.10 14.60 116.7 102.3 14.1 98.3 P 5 DT 6 sewer backfill -2 S-1 0.00 104.10 14.60 121.4 107.3 13.1 103.1 P 6 DT 6 sewer backfill -3 S-1 0.00 104.10 14.60 122.5 104.0 17.7 99.9 P 7 DT 6 sewer backfill -1 S-1 0.00 104.10 14.60 120.8 105.0 15.0 100.9 P 8 DT 6 sewer backfill -2 S-1 0.00 104.10 14.60 122.5 105.3 1 16.3 101.2 P 9 DT 6 sewer backfill -1 S-1 0.00 104.10 14.60 118.7 106.7 11.3 102.5 P 10 DT 6 sewer backfill -2 S-1 0.00 104.10 14.60 122.5 104.0 17.7 99.9 P Test Mode: DT = Direct Transmission BS = Back Scatter Transmittal Page 4/4 W C :166593