Loading...
HomeMy WebLinkAboutNC0083119_Fact Sheet_20190311FACT SHEET FOR EXPEDITED PERMIT RENEWALS This form must be completed by Permit Writers for all expedited permits which do not require full Fact Sheets. Expedited permits are generally simple 100% domestics (e.g., schools, mobile home parks, etc) that can be administratively renewed with minor changes, but can include facilities with more complex issues (Special Conditions, 303(d) listed water, toxicity testing, instream monitoring, compliance concerns). Basic Information for Expedited Permit Renewals Permit Writer / Date Sydney Carpenter 1/11/2019 Permit Number NCO083119 Facility Name / Facility Class Coddle Creek WTP / PC-1 Basin Name / Sub -basin number Yadkin -Pee Dee / 03-07-11 Receiving Stream / HUC UT to Coddle Creek / 030401050105 Stream Classification / Stream Segment C / Index: 13-17-6- 5.5 Does permit need Daily Max NH3 limits? No Does permit need TRC limits/language? Already included. Does permit have toxicity testing? IWC if so. Yes; IWC % is 90 Does permit have Special Conditions? Yes — Chronic Toxicity Monitoring (Quarterly) Does permit have instream monitoring? No Is the stream impaired (on 303(d) list)? If yes, for what arameter(s)? Yes — Benthos (Nar, AL, FW) Any obvious compliance concerns? Three NOV cases since last renewal; Two in 2018 for TSS limit, one in 2014 for Fluoride limit. TSS, pH and Flow monitoring violation in Nov 2018. Any permit mods since lastpermit? No New expiration date 11/30/2023 Facility Overview: The Coddle Creek WTP operates a conventional treatment WTP designed for a potable flowrate of 12 MGD and a continuous wastewater (backwash) discharge of 0.6 MGD. Treatment process for raw water consists of oxidation with potassium permanganate, taste and odor control with powdered activated carbon, coagulation and sedimentation using aluminum sulfate and a coagulant aid polymer. Sludge and filter backwash water is discharged to two lagoons, where settling occurs and the supernate is dechlorinated then discharged into the UT to Coddle Creek. The maximum, monthly average wastewater discharge between Oct 2015 and Oct 2018 was approximately 0.9291 MGD. Compliance History: • Three NOV cases since last renewal; Two in 2018 for TSS limit, one in 2014 for Fluoride limit. TSS, pH and Flow monitoring violation in Nov 2018. • Within the past three years, the facility has failed three TOX tests; Jan 2016, Oct 2017, Jul 2018. RPA: The maximum, monthly average wastewater discharge between Oct 2015 and Oct 2018 was approximately 0.9291 MGD. • Fluoride — reasonable potential to exceed water quality standards; maintaining current limits and monthly monitoring. • Iron — no reasonable potential, as there are no water quality standards currently. No values were over 1 mg/L. Removing parameter from effluent table. NCG59 General Permit Eligibility (for Conventional & Greensand WTPs): • They've failed 3 TOX tests within the last 3 years (Oct 2015-Oct 2018), the most recent failed test occurring in July 2018 — ineligible • Fluoride limits required based on most recent RPA — ineligible • Conclusion: Ineligible for NCG59 General Permit. Changes from previous permit to draft: • Updated permit map. • Removed former footnote #4 stating "Parameters should be monitored in conjunction with toxicity test.", as this is no longer required per 2009 Changes to WTP Strategy Memo • Removed Iron parameter in A(1) Effluent table. Application states Iron sulfate does not have the potential to be discharged. As per "Assistance with BPJ on WTP renewals" 2012 Memo, Iron does not have a recommend limit and was monitoring only in previous permit. All reported values in previous 4 '/2 years are < 1 mg/L. • Removed daily max limit for Turbidity and updated monitoring frequency to 2/Monthly per Table 5.1 in the "Assistance with BPJ on WTP renewals" 2012 Memo. Receiving stream no longer impaired for Turbidity. • Removed Zinc from A.(1) Effluent Table as permit application states Zinc - orthophosphate or sweetwater CP1236 does not have the potential to be discharged. Removed corresponding former footnote #2. • Added regulatory citations • Added eDMR footnote in A(1) and updated Section A(4). • Updated former footnote #5 (now footnote #4) regarding WET testing. • Updated information on Supplement to Cover Sheet to include max monthly average, stream index, and HUC. • Added facility grade in A(1) • Added eDMR parameter codes to effluent table in Section A. (1) • Updated measurement frequency for flow in A.(1) Effluent Table to continuous, per WTP strategy as the facility discharges > 50,000 GPD. • Removed former Section A. (3.) Permit Re -Opener — Whole Effluent Toxicity special condition as the facility has passed > 75% of TOX tests in the last 3 years. • Removed Ammonia Nitrogen from A.(1) Effluent Table as the application states that ammonia nitrogen/chloramines do not have the potential to be discharged and is not shown on the provided facility schematic. Corresponding former footnote #3 stating "Facilities using chlorination will be required to monitor ammonia nitrogen on a quarterly basis." has also been removed. Changes from draft to final: • None Comments received on draft permit: • None Water Resources ENWRONMEUTAL QUALITY May 11, 2018 Christie Putnam City of Concord 9000 Aviation Blvd Concord, NC 28027 Subject: Permit Renewal Application No. NCO083119 Coddle Creek WTP Cabarrus County Dear Applicant: ROY COOPER Garernar h-UCHAEL S. REGAN Secretary L=A CULPEPPER Interim Directar The Water Quality Permitting Section acknowledges the May 10, 2018 receipt of your permit renewal application and supporting documentation. Your application will be assigned to a permit writer within the Section's NPDES WW permitting branch. Per G.S. 150B-3 your current permit does not expire until permit decision on the application is made. Continuation of the current permit is contingent on timely and sufficient application for renewal of the current permit. The permit writer will contact you if additional information is required to complete your permit renewal. Please respond in a timely manner to requests for additional information necessary to allow a complete review of the application and renewal of the permit. Information regarding the status of your renewal application can be found online using the Department of Environmental Quality's Environmental Application Tracker at: https•//deq nc gov/permits-regulations/permit-guidance/environmental-application-tracker If you have any additional questions about the permit, please contact the primary reviewer of the application using the links available within the Application Tracker. Sincer ely, Wren Thedford Administrative Specialist II Water Quality Permitting Section ec: WQPS Laserfiche File w/application State of North Carolina I Environmental Quality I Water Resources 1617 Mail Service Center I Raleigh, North Carolina 27699-1617 919-807-6300 7 May 2018 NC DENR / DWR / NPDES Unit 1617 Mail Service Center Raleigh, NC 27699-1617 Dear Mr. Thedford: p%ECiE EDjDE PJD\ Y n MAY to 2019 N►ater Re g- tGes Permilttmg The City of Concord requests renewal of the NPDES permit for the Coddle Creek WTP. The current permit number for Coddle Creek WTP is # NC0083119. There have been no changes at Coddle Creek WTP since the issuance of the last permit. Thank you for your assistance with this matter. Sincerely, Christie Putnam Water Resources Director, City of Concord Enclosures NPDES PERMIT APPLICATION - SHORT FORM C - WTP For discharges associated with water treatment plants Mail the complete application to: N. C. Department of Environment and Natural Resources Division of Water Quality / NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 NPDES Permit Number INCO083119 If you are completing this form in computer use the TAB key or the up - down arrows to move from one field to the next. To check the boxes, click your mouse on top of the box. Otherwise, please print or type. 1. Contact Information: Owner Name Facility Name Mailing Address City State / Zip Code Telephone Number Fax Number City of Concord Coddle Creek Water Treatment Plant P.O. Box 308 Concord North Carolina 28026 (704) 920-5164 (704) 795-0404 e-mail Address campbellr@concordnc.gov 2. Location of facility producing discharge: Check here if same as above ❑ Street Address or State Road City State / Zip Code County 6935 Davidson Highway Concord North Carolina 28027 Cabarrus 3. Operator Information: Name of the firm, consultant or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name City of Concord Mailing Address P.O. Box 308 City Concord State / Zip Code North Carolina 28026 Telephone Number (704) 920-5164 Fax Number (704) 795-0404 4. Ownership Status: Federal ❑ State ❑ Private ❑ Public Id Page 1 of 3 Version 5/2012 NPDES PERMIT APPLICATION - SNORT FORM C - WTP For discharges associated with water treatment plants 5. Ty p f treatment plant: Conventional (Includes coagulation, flocculation, and sedimentation, usually followed by filtration and disinfection) ❑ Ion Exchange (Sodium Cycle Cationic ion exchange) ❑ Green Sand Filter (No sodium recharge) ❑ Membrane Technology (RO, nanofiltration) Check here if the treatment process also uses a water softener ❑ 6. Description of source water(s) (i.e. groundwater, surface water) Surface water 7. Describe the treatment process(es) for the raw water: Oxidation with potassium permanganate; taste and odor control with powdered activated carbon; coagulation and sedimentation, using aluminum sulfate and coagulant aid polymer 8. Describe the wastewater and the treatment process(es) for wastewater generated by the facility: Settled sludge and filtered backwash water is discharged to two lagoons where settling occurs. The supernate is drafted off through discharge gates and dechlorinated, using calcium thiosulfate, prior to its release at the discharge weir. 9. Number of separate discharge points: 1 Outfall Identification number(s) 001 10. Frequency of discharge: Continuous [ Intermittent ❑ If intermittent: Days per week discharge occurs: N/A Duration: N/A 11. Plant design potable flowrate 12 MGD Backwash or reject flow 0.6 MGD 12. Name of receiving stream(s) (Provide a map showing the exact location of each outfall, including latitude and longitude): Coddle Creek 13. Please list all water treatment additives, including cleaning chemicals or disinfection treatments, that have the potential to be discharged. Alum / aluminum sulfate Yes X No Page 2 of 3 Version 5/2012 NPDES PERMIT APPLICATION - SHORT FORM C - WTP For discharges associated with water treatment plants Iron sulfate / ferrous sulfate Yes No X Fluoride Yes X No Ammonia nitrogen / Chloramines Yes No X Zinc -orthophosphate or sweetwater CP1236 Yes No X List any other additives below: Powdered activated carbon, potassium permanganate, coagulant aid polymer Sodium hypochlorite, sodium hydroxide, polyphosphate, calcium thiosulfate 14. Is this facility located on Indian country? (check one) Yes ❑ No e 15. Additional Information: ➢ Provide a schematic of flow through the facility, include flow volumes at all points in the water treatment process. The plan should show the point[s] of addition for chemicals and all discharges routed to an outfall [including stormwater]. ➢ Solids Handling Plan 16. NEW Applicants Information needed in addition to items 1-15: ➢ New applicants are highly encouraged to contact a permit coordinator with the NCDENR Customer Service Center. Was the Customer Service Center contacted? ❑ Yes ❑ No ➢ Analyses of source water collected ➢ Engineering Alternative Analysis ➢ Discharges from Ion Exchange and Reverse Osmosis plants shall be evaluated using a water quality model. 17. Applicant Certification I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. name of Person Signing Title ture of Ax @icant Date North Carolina General Statute 143-215.6 (b)(2) provides that: Any person who knowingly makes any false statement representation, or certification in any application, record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or by imprisonment not to exceed six months, or by both (18 U S C Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5 years, or both, for a similar offense) Page 3 of 3 Version 5/2012 Coddle Creek Water Treatment Plant Lagoon System Sludge Removal Plan NPDES permit # NCO083119 The City of Concord contracts with a private company, to remove sludge from the Coddle Creek Water Treatment Plant (WTP) lagoons. The sludge removal contract is bid out to various firms; the low bidder on the current project is Bio-Nomic Services, Inc. (516 Roundtree Road, Charlotte, NC 28217-2133). Sludge has been removed from the Coddle Creek lagoon approximately every 11/2 years. The quantities of sludge average between 4500 — 5500 tons. The sludge is deposited at the BFI landfill in Concord, NC. City of Concord Coddle Creek WTP Latitude: 35' 25' 57" N State Grid: Concord Longitude: 80' 41' 40" W Permitted Flow: 100 MGD Receiving stream: UT to Coddle Creek Stream Class: C Drainage Basin: Yadkin -Pee Dee River Basin Sub -Basin: 03-07-11 Facility x Location not to scale NPDES Permit No. NCO083119 North I I Cabarrus County 9 h Car vv� 1 gc�,s%r ROW ` oAer L _ (IrA MG1 0 a MG) , (� �`���pLA Ca-4cs5►Urm —'� Tf4ake- Qe r mGh�4nc}� p Is �c►5ih Pow Bred (►a MG) H(DW V 1--1 u rn A ck�'�.ta e�l C o� r b of fi l o� a55 1 day Ca me a 5 i r 4- Se.c�irne�n�Q�iOv� ('-1 mG� S e cis 1 w\ VA c�� � o v� d ca S i v� �---- CIa mG) C3 A1um,v,u� �--_ ( a Sea-, V" c V-jA u� ,o r% C'�c� s i h Su 1 raj e Sad�uVr' aa7vvlosv%a�e NyP°�1�►0 �t� ('3MG)lY yr e-r Ip ►O h �' Slv►�c� e Pum Q 5 o� S o. S i E�— �!5`:tsx� ct}Q-r71<Djc, Re.ce'%vd'n5 Calciurm D isclharge we IY' Independent Tribune Advertising Affidavit PO Box 968 Hickory, NC 28603 NC DENR/DWQ ATTN: WREN THEDFORD 1617 MAIL SERVICE CENTER RALEIGH, NC 27699-1617 Account Number 3142720 Date January 25, 2019 Date Category Description Ad Number Ad Size 01/25/2019 Legal Notices 1611 Oabserviceceohc Pakigh,NC 2169�1611 Notice of Nlmt h Issue a IODES Wa9ewat� PaunN De Nod Carolina Enuimnmenhl Management Commission proposes to slue a 05 wastewater dhcWc peril to the perssc$) li ted below. Wlittm commit regardiq the proposed permit will be a erfed red 10 days after the publish dale of this rroNce.1h Direct« of he NC W. sianofWill Resoures(DWIlnoijMIipublic ho N sbould In be i significant degree of public intereiL Please nail camrards and/or infor• Ulan requesD to DWI it& gave addrn Irderes« persons may ds R th DWR at 512 N. Salisbury Sbcef, Pill NC to review infolmili n on file. AddOonal infomat'an on NPDES permit and din notice may be Irmhoes,a ty cvling 119)101-OR the Cidl el Gomad has repl¢ded mnewd of NW6 permit NNW 10I1119/Coddle CreeM F) in Will County. facility discharges belted filter birldinh ton Unnamed tddub. ry to Code CnekrYadkin-Pee Dee Over Basin. Curadv, tahl residual chbdne a water Ill limited, the City of Concord Nis reQucetld re- newal of NPOE cermR 01121191Coddle CA W? in Cabarrus Cwo. ty, facility discharges Ireafed flier backwash to in Mind d bibutary to Coddle CreeplYadkin•Pee Dee Over Basin Currently, tom/ reddud R- ine is Wahl Ally limiled. Public Notice North Carolina Environmental Management Comm 0000536521 2 x 28 L Publisher of Independent Tribune Cabarrus County Before the undersigned, a Notary Public of Iredell County, North Carolina, duly commissioned, qualified, and authorized by law to administer oaths, in said County and State; that he/she is authorized to make this affidavit and sworn statement; that the notice or other legal advertisement, a copy of which is attached hereto, was published in the Independent Tribune on the following dates: 01/25/2019 and that the said newspaper in which such notice, or legal advertisement was published, was a newspaper meeting all the requirements and qualifications of Section 1-597 of the General Statutes of North Carolina. Asststunt Bookkeeper Newspaper reference: 0000536521 J Sworn to and subscribed before me, this _� day of`� 2019 QPs�Unmiifim��O / Notary Public 6! i a ! Nolory Publio iredeu County My Commission expires: % a17. ,-b@' ) —r— 10 P rH CA R 0��� THIS IS NOT A BILL. PLEASE PAY FROM INVOICE, THANK YOU Freshwater RPA - 95% Probability/95% Confidence Using Metal Translators MAXIMUM DATA POINTS = 58 REQUIRED DATA ENTRY Table 1. Project Information ]CHECK IF HQW OR ORW WQS Facility Name Par01 Coddle Creek WTP WWTP/WTP Class PC-1 Par02 NPDES Permit NCO083119 Par03 Outfall 001 Par04 Flow, Qw (1 0.929 Par05 Receiving Stream UT to Coddle Creek Par06■ HUC Number 03040105 Par07 Stream Class C 0.00 Par08 Par09 Par10 ]Apply WS Hardness WQC 7Q10s (cfs) 7Q10w (cfs) 0.00 Par11 311 (cfs) 0.00 Par12 QA (cfs) 0.00 Par13 1Q10s (cfs) Par14 Par15 0.00 Effluent Hardness NO EFFLUENT HARDNESS DATA ----------------------------------- Upstream Hardness NO UPSTREAM HARDNESS DATA I Par16 ----------------------------------- Combined Hardness Chronic -- DATA INCOMPLETE I Par17 -- — Combined Hardness Acute ----- ---------- ---- -- DATA INCOMPLETE ------I I Par18 I Par19 Par20 Data Source(s) ❑CHECK TO APPLY MODEL Par21 Par22 Par23 Par24 Table 2. Parameters of Concern Name WQS Type Chronic Modifier Acute i Units Arsenic Aquactic Life C 150 FW 340 ug/L Arsenic Human Health Water Supply C 10 Hi N/A ug/L Beryllium Aquatic Life NC 6.5 FW 65 ug/L Cadmium Aquatic Life NC NO DATA FW NO DATA ug/L Chlorides Aquatic Life NC 230 FW mg/L 11, Chlorinated Phenolic Compounds Water supply NC 1 A ug/L Total Phenolic Compounds Aquatic Life NC 300 A ug/L Chromium III Aquatic Life NC NO DATA FW NO DATA ug/L Chromium VI Aquatic Life NC 11 FW 16 pg/L Chromium, Total Aquatic Life NC N/A FW N/A pg/L Copper Aquatic Life NC NO DATA FW NO DATA ug/L Cyanide Aquatic Life NC 5 FW 22 10 ug/L Fluoride Aquatic Life NC 1,800 FW ug/L Lead Aquatic Life NC NO DATA FW NO DATA ug/L Mercury Aquatic Life NC 12 FW 0.5 ng/L Molybdenum Human Health NC 2000 HH ug/L Nickel Aquatic Life NC NO DATA FW NO DATA pg/L Nickel Water Supply INC 25.0000 WS N/A pg/L Selenium Aquatic Life INC 5 FW 56 ug/L Silver Aquatic Life NC 0.06 FW NO DATA ug/L Zinc Aquatic Life NC NO DATA FW NO DATA ug/L Iron Aquatic Life NC 1 FW mg/L 83119 RPA, input 4/1 /2019 Coddle Creek WTP NCO083119 Freshwater RPA - 95% Probability/95% Confidence Using Metal Translators MAXIMUM Qw (MGD) = 0.9292 1Q10S (cfs) = 0.00 7Q10S (cfs) = 0.00 7Q10W (cfs) = 0.00 30Q2 (cfs) = 0.00 Avg. Stream Flow, QA (cfs) = 0.00 Receiving Stream: UT to Coddle Creek HUC 03040105 DATA POINTS = 58 WWTP/WTP Class: PC-1 IWC% @ 1Q10S = 100 IWC% @ 7Q10S = 100 IWC% @ 7Q10W = 100 1WC% @ 30Q2 = 100 IW%C @ QA = 100 Stream Class: C Outfall 001 Qw = 0.92915 MGD COMBINED HARDNESS (me/L) NO DATA NO DATA PARAMETER NC STANDARDS OR EPA CRITERIA REASONABLE POTENTIAL RESULTS RECOMMENDED ACTION TYPE o Applied Chronic Acute n # Det. Max Pred Cw Allowable Cw Standard Acute: NO WQS Fluoride NC 1800 FW ug L 54 4 3,360.0 Chronic: 1,800.0 RP shown - apply Monthly Monitoring with Limit 1 values > Allowable Cw Acute: NO WQS Iron NC 1 FW mg/L 18 12 0.61451 ___ _ ____ _ _ _ Chronic: 0 _ _ _ _ _ _ _ _ _ _______ No RP shown - no monitoring required. w No value > Allowabllee CCw Acute: 0 0 N/A — -Chronic: - — - — - — - — - — -------------------------- Acute: 0 0 N/A _ __________ Chronic: Acute: 0 0 N/A _ __________ Chronic: 83119 RPA, rpa Page 3 of 3 4/1/2019 REASONABLE POTENTIAL ANALYSIS 3 Fluoride Date Data BDL=1/2DL Results 1 6/10/2014 3200 3200 Std Dev. 2 7/8/2014 < 500 250 Mean 3 8/5/2014 < 500 250 C.V. 4 9/2/2014 < 500 250 n 5 10/21 /2014 < 500 250 6 11/4/2014 660 660 Mult Factor = 7 12/2/2014 < 500 250 Max. Value 8 1/20/2015 < 500 250 Max. Pred Cw 9 2/3/2015 < 500 250 10 3/3/2015 < 500 250 11 4/7/2015 < 500 250 12 5/12/2015 < 500 250 13 6/2/2015 < 500 250 14 7/28/2015 < 500 250 15 8/4/2015 < 500 250 16 9/8/2015 < 500 250 17 10/13/2015 < 500 250 18 11 /3/2015 < 500 250 19 12/8/2015 < 500 250 20 1/19/2016 < 500 250 21 2/9/2016 < 500 250 22 3/1/2016 < 500 250 23 4/19/2016 < 500 250 24 5/3/2016 < 500 250 25 6/7/2016 < 500 250 26 7/19/2016 < 500 250 27 8/2/2016 < 500 250 28 9/6/2016 < 500 250 29 10/18/2016 < 500 250 30 11 /1 /2016 < 500 250 31 12/6/2016 < 500 250 32 1/17/2017 < 500 250 33 2/7/2017 < 500 250 34 3/7/2017 < 500 250 35 4/18/2017 < 100 50 36 5/2/2017 < 100 50 37 6/6/2017 < 100 50 38 7/18/2017 < 100 50 39 8/1/2017 < 100 50 40 9/5/2017 < 100 50 41 10/3/2017 < 100 50 42 11/7/2017 < 100 50 43 12/5/2017 < 100 50 44 1/9/2018 < 100 50 45 2/6/2018 < 100 50 46 3/6/2018 < 100 50 47 4/2/2018 < 100 50 48 5/1/2018 < 100 50 49 6/5/2018 < 100 50 50 7/3/2018 110 110 51 8/7/2018 110 110 52 9/5/2018 < 100 50 53 10/2/2018 < 100 50 54 11/6/2018 < 100 50 55 56 57 58 Use "PASTE SPECIAL Values" then "COPY" . Maximum data points = 58 Pa7 240.3704 1.7729 54 1.05 3200.0 ug/L 3360.0 ug/L Use "PASTE SPECIAL Iron Values" then "COPY" . Maximum data points = 58 Date Data BDL=1/2DL Results 1 7/8/2014 < 0.06 0.03 Std Dev. 2 10/21/2014 0.109 0.109 Mean 3 1/20/2015 0.105 0.105 C.V. 4 4/7/2015 0.101 0.101 n 5 7/28/2015 0.172 0.172 6 10/13/2015 0.193 0.193 Mult Factor = 7 1/19/2016 0.164 0.164 Max. Value 8 4/19/2016 0.076 0.076 Max. Pred Cw 9 7/19/2016 0.068 0.068 10 10/18/2016 < 0.05 0.025 11 1/17/2017 0.0797 0.0797 12 4/18/2017 < 0.05 0.025 13 7/18/2017 < 0.05 0.025 14 10/3/2017 < 0.05 0.025 15 1/9/2018 < 0.05 0.025 16 4/2/2018 0.377 0.377 17 7/10/2018 0.102 0.102 18 10/2/2018 0.343 0.343 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 0.1136 0.9197 18 1.63 0.377000 mg/L 0.614510 mg/L 83119 RPA, data 1 4/1/2019 IWC Calculations Coddle Creek WTP NC0083119 Prepared By: Sydney Carpenter, NPDES Program Enter Design Flow (MGD): 0.92915 Enter s7Q10(cfs): 0 Enter w7Q10 (cfs): 0 Residual Chlorine Ammonia (NH3 as N) (summer) 7Q10 (cfs) 0 7Q10 (CFS) 0 DESIGN FLOW (MGD) 0.92915 DESIGN FLOW (MGD) 0.92915 DESIGN FLOW (cfs) 1.4401825 DESIGN FLOW (cfs) 1.44018 STREAM STD (ug/L) 17.0 STREAM STD (mg/L) 1.0 UPS BACKGROUND LEVEL (1 0 UPS BACKGROUND LEVEL (mg/L) 0.22 IWC (%) 100.00 IWC (%) 100.00 Allowable Conc. (ug/1) 17 Allowable Conc. (mg/1) 1.0 Ammonia (NH3 as N) (winter) 7Q10 (CFS) 0 Fecal Limit 200/100ml DESIGN FLOW (MGD) 0.92915 (If DF >331; Monitor) DESIGN FLOW (cfs) 1.44018 (If DF <331; Limit) STREAM STD (mg/L) 1.8 Dilution Factor (DF) 1.00 UPS BACKGROUND LEVEL (mg/L) 0.22 IWC (%) 100.00 Allowable Conc. (mg/1) 1.8 INPDES Servor/Current Versions/IWC 4/1/2019 Whole Effluent Toxicity Testing and Self Monitoring Summary CMUD-McAlpine WWTP NCO024970/001 County: Mecklenburg Ceri7dPF Begin: 10/1/2017 chr lim: 90% NonComp: Single J F M A M 2015 >100(P) Pass(s) 2016 H Pass(s) 2017 Pass(s) 2018 Pass(s) >100(P) I CMUD-McDowell Cr. WWTP NCO036277/001 County: Mecklenburg Ceri7dPF Begin: 1/1/2014 chr lim.: 90% NonComp: Single J F M A M 2015 Pass(s) Pass(s) 2016 Pass Invalid Pass 2017 Pass(s) Pass(s) 2018 92.5(P) Pass(s) Pass(s) CMUD-Sugar Cr. WWTP NCO024937/001 County: Mecklenburg Ceri7dPF Begin: 10/1/2017 chr lim: 90% NonComp: Single J F M A M 2015 Fail(s) >100(P) Pass >100 >100(s) Pass(s) 2016 Pass(s) - Pass(s) 2017 Pass(s) Pass(s) 2018 Pass >100(P) - Pass(s) CNA Holdings, Inc.(Ticona Facility) NC0004952/001 County: Cleveland Ceri7dPF Begin: 11/1/2013 chr lim: 2.13% NonComp: Single J F M A M 2015 Pass 2016 Pass 2017 Pass 2018 Pass Coats American -Sevier Plant NC0004243/001 County: McDowell Ceri7dPF Begin: 12/1/2017 chr lim: 15% NonComp: Single J F M A M 2015 Pass - - Pass 2016 Fail >30 25.98 Pass 2017 Pass - - Pass 2018 Pass - Pass Coddle Creek WTP NCO083119/001 County: Cabarrus Ceri7dPF Begin: 12/1/2013 Chr Monit: 90% NonComp: J F M A M 2015 Fail Fail 2016 Fail Pass 2017 Pass Pass 2018 Pass Pass Region: MRO Basin: CTB34 Mar Jun Sep Dec SOC JOC: 7Q10: 0.3 PF: 64.0 IWC: 99.35 Freq: Q J J A S O N Pass(s) Pass(s) - Pass(s) Pass(s) Pass(s) Pass(s) Pass(s) Pass - Region: MRO Basin: CTB33 Jan Apr Jul Oct SOC JOC: 7Q10: 1.80 PF: 12.0 IWC: 85 Freq: Q J J A S O N Pass Pass(s) Pass(s) Pass(s) >100(P) Pass(s) Pass 92.5(P) Pass(s) Pass(s) Region: MRO Basin: CTB34 Feb May Aug Nov C_JOC: K.SO 7Q10: 3.4 PF: 20.0 IWC: 90 Freq: Q J J A S O N - Pass(s) Pass(s) >100(P) Pass(s) Pass(s) Pass(s) >100(P) Pass Pass Region: MRO Basin: BRD05 Mar Jun Sep Dec SOC JOC: 7Q10: 20.0 PF: 0.45 IWC: 5.8 Freq: Q J J A S O N Pass Pass - Pass Pass Pass Pass Pass Pass - Region: ARO Basin: CTB30 Feb May Aug Nov SOC JOC: 7Q10: 18.0 PF: 2.0 IWC: 14.7 Freq: Q J J A S O N Pass Pass Pass - Pass Pass Pass Pass Pass Pass - Pass Region: MRO Basin: YAD11 Jan Apr Jul Oct SOC JOC: 7Q10: PF: 0.30 IWC: Freq: Q J J A S O N Fail Pass Pass Pass Pass Fail Fail Pass D Pass(s) Pass(s) Pass(s) >100(P) Pass(s) C D Pass Pass Pass Pass r C Leeend: P= Fathead minnow (Pimohales oromelas). H=No Flow (facility is active). s = Split test between Certified Labs Page 20 of 108