Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
960051_INSPECTIONS_20171231
2' NUH I H UAHULINA Department of Environmental Qual INSPECTIONS INSPECTIONS INSPECTIONS ft Division of Water Resources ❑ Division of Soil and Water Conservation ❑ Other Agency Facility Number: 960051 Facility Status: Active Permit: AWS960051 ❑ Denied Access Inppection Type: Compliance Inspection Inactive Or Closed Date: Reason for Visit: Routine County: Wayne Region: Washington Date of Visit: 08/29/2017 Entry Time: 08:05 am Exit Time: 9:45 am Incident # Farm Name: Daw & Son Farm Owner Email: Owner: Daw Farms Inc Phone: 919-734-6410 Mailing Address: 653 Hare Rd Goldsboro NC 27534 Physical Address: 1041 Mt Cannel Church Rd Pikeville NC 27863 Facility Status: Compliant ❑ Not Compliant Integrator: Maxwell Foods LLC Location of Farm: Latitude: 35` 28' 25" Longitude: 77' 56' 36" SR 1545, 2 miles north of SR 1523, west side of road. Question Areas: Dischrge & Stream Impacts Waste Col, Stor, & Treat Waste Application Records and Documents Other Issues Certified Operator: Paul Lewt Daw Operator Certification Number: 26042 Secondary OIC(s): On -Site Representative(s): Name Title Phone 24 hour contact name Brent Mitchell Phone : 919-738-3584 Primary Inspector: Justin K Davis Phone: Inspector Signature: Date: Secondary Inspector(s): Inspection Summary page: 1 r �+ Permit: AWS960051 Owner - Facility : Daw Farms Inc Facility Number: 960051 Inspection Date: 08/29/17 Inpsection Type: Compliance Inspection Reason for Visit: Routine Waste Report N 6-22-17 1.24 4-7-17 0.94 10-20-2016 0.99 Soil Report 12-28-2016 Zn<600 Cu<300 Calibration due 2017 2015 Lagoon Sludge Survey 11-27-2016 LTZ 3.3 T 3.8 PI 3.2 45% page: 2 .. y Permit: AWS960051 Owner - Facility : Daw Farms Inc Facility Number: 960051 Inspection Date: 08/29/17 Inpsection Type: Compliance Inspection Reason for Visit: Routine Regulated Operations Design Capacity Current promotions Swine Sw ne - Wean to Feeder 3,200 2,559 Total Design Capacity: 3,200 Total SSLW: 96,000 Waste Structures Disignated Observed Type Identifier Closed Date Start Date Freeboard Freeboard Lagoon PRIMARY 06/01/92 19.00 43.00 page: 3 ► "" Permit: AWS960051 Owner -Facility: Daw Farms Inc Facility Number: 960051 Inspection Date: 08/29/17 Inpsection Type: Compliance Inspection Reason for Visit: Routine Discharges & Stream Impacts Yes No Na Ne 1. Is any discharge observed from any part of the operation? ❑ 0 ❑ ❑ Discharge originated at: Structure ❑ Application Field ❑ Other ❑ a. Was conveyance man-made? ❑ ❑ ❑ b. Did discharge reach Waters of the State? (if yes, notify DWQ) ❑ M ❑ ❑ c. What is the estimated volume that reached waters of the State (gallons)? d. Does discharge bypass the waste management system? (if yes, notify DWQ) ❑ ❑ ❑ 2. Is there evidence of a past discharge from any part of the operation? ❑ ❑ ❑ 3. Were there any observable adverse impacts or potential adverse impacts to Waters of the ❑ M ❑ ❑ State other than from a discharge? Waste Collection, Storage & Treatment Yes No Na Ne 4. Is storage capacity less than adequate? ❑ 0 ❑ ❑ If yes, is waste level into structural freeboard? ❑ 5. Are there any immediate threats to the integrity of any of the structures observed (I.e./ large ❑ M ❑ ❑ trees, severe erosion, seepage, etc.)? 6. Are there structures on -site that are not properly addressed and/or managed through a ❑ 0 ❑ ❑ waste management or closure plan? 7. Do any of the structures need maintenance or improvement? ❑ 0 ❑ ❑ 8. Do any of the structures lack adequate markers as required by the permit? (Not applicable ❑ M ❑ ❑ to roofed pits, dry stacks and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require ❑ M ❑ ❑ maintenance or improvement? Waste Application Yes No Na Ne 10. Are there any required buffers, setbacks, or compliance alternatives that need ❑ 0 ❑ ❑ maintenance or improvement? 11. Is there evidence of incorrect application? ❑ M ❑ ❑ If yes, check the appropriate box below. Excessive Ponding? ❑ Hydraulic Overload? ❑ Frozen Ground? ❑ Heavy metals (Cu, Zn, etc)? ❑ PAN? ❑ Is PAN > 10%/10 lbs.? ❑ Total Phosphorus? ❑ Failure to incorporate manure/sludge into bare soil? ❑ Outside of acceptable crop window? ❑ Evidence of wind drift? ❑ Application outside of application area? ❑ page: 4 ae . Permit: AWS960051 Owner - Facility : Daw Farms Inc Facility Number: 960051 Inspection Date: 08/29/17 Inpsection Type: Compliance Inspection Reason for Visit: Routine Waste Application Yes No Na No Crop Type 1 Crop Type 2 Crop Type 3 Crop Type 4 Crop Type 5 Crop Type 6 Soil Type 1 Soil Type 2 Soil Type 3 Soil Type 4 Soil Type 5 Soil Type 6 14. Do the receiving crops differ from those designated in the Certified Animal Waste ❑ 0 ❑ ❑ Management Plan(CAWMP)? 15. Does the receiving crop and/or land application site need improvement? ❑ 0 ❑ ❑ 16. Did the facility fail to secure and/or operate per the irrigation design or wettable acre ❑ 0 ❑ ❑ determination? 17_ Does the facility lack adequate acreage for land application? ❑ 0 ❑ ❑ 18. Is there a lack of properly operating waste application equipment? ❑ E ❑ ❑ Records and Documents Yes No Na Ne 19. Did the facility fail to have Certificate of Coverage and Permit readily available? ❑ 0 ❑ ❑ 20. Does the facility fail to have all components of the CAWMP readily available? ❑ 0 ❑ ❑ If yes, check the appropriate box below. WUP? ❑ Checklists? ❑ Design? ❑ Maps? ❑ Lease Agreements? ❑ Other? ❑ If Other, please specify 21. Does record keeping need improvement? ❑ 0 ❑ ❑ If yes, check the appropriate box below. Waste Application? ❑ Weekly Freeboard? ❑ Waste Analysis? ❑ Soil analysis? ❑ Waste Transfers? ❑ Weather code? ❑ Rainfall? ❑ Stocking? ❑ page: 5 i � d Permit: AWS960051 Owner -Facility: Daw Farrns Inc Facility Number: 960051 Inspection Date: 08/29/17 Inpsection Type: Compliance Inspection Reason for Visit: Routine Records and Documents Yes No Na Ne Crop yields? ❑ 120 Minute inspections? ❑ Monthly and 1" Rainfall Inspections ❑ Sludge Survey ❑ 22. Did the facility fail to install and maintain a rain gauge? ❑ 0 ❑ ❑ 23. If selected, did the facility fail to install and maintain a rainbreaker on irrigation equipment ❑ MEJ ❑ (NPDES only)? 24. Did the facility fail to calibrate waste application equipment as required by the permit? ❑ M ❑ ❑ 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check the ❑ 0 ❑ ❑ appropriate box(es) below: Failure to complete annual sludge survey ❑ Failure to develop a POA for sludge levels ❑ Non -compliant sludge levels in any lagoon ❑ List structure(s) and date of first survey indicating non-compliance: 26. Did the facility fail to provide documentation of an actively certified operator in charge? ❑ 0 ❑ ❑ 27. Did the facility fail to secure a phosphorous loss assessment (PLAT) certification? ❑ ❑ ❑ Other Issues Yes No Na Ne 28. Did the facility fail to properly dispose of dead animals within 24 hours and/or document ❑ 0 ❑ ❑ and report mortality rates that exceed normal rates? 29. At the time of the inspection did the facility pose an odor or air quality concern? If yes, ❑ 0 ❑ ❑ contact a regional Air Quality representative immediately. 30. Did the facility fail to notify regional DWQ of emergency situations as required by Permit? ❑ M ❑ ❑ (i.e., discharge, freeboard problems, over -application) 31. Do subsurface tile drains exist at the facility? ❑ M ❑ ❑ If yes, check the appropriate box below. Application Field ❑ Lagoon / Storage Pond ❑ Other ❑ If Other, please specify 32. Were any additional problems noted which cause non-compliance of the Permit or ❑ 0 ❑ ❑ CAWMP? 33, Did the Reviewer/Inspector fail to discuss review/inspection with on -site representative? ❑ 0 ❑ ❑ 34. Does the facility require a follow-up visit by same agency? ❑ E ❑ ❑ page: 6 0 Division of Water Resources ❑ Division of Soil and Water Conservation ❑ Other Agency Facility Number: 960051 Facility Status: Active Permit: AWS960051 ❑ Denied Access Inpsection Type: Compliance Inspection Inactive Or Closed Date: Reason for Visit: Routine County: Wayne Region: Washington Date of Visit: 08/24/2016 Entry Time: 07:30 am Exit Time: 8:35 am Incident # Farm Name: Daw & Son Farm Owner Email: Owner: Daw Farms Inc Phone: 919-734-6410 Mailing Address: 653 Hare Rd Goldsboro NC 27534 Physical Address: 1041 Mt Carmel Church Rd Pikeville NC 27863 Facility Status: 0 Compliant ❑ Not Compliant Integrator: Maxwell Foods LLC Location of Farm: Latitude: 35° 28' 25" Longitude: 77' 56' 36" SR 1545, 2 miles north of SR 1523, west side of road. Question Areas: Dischrge & Stream Impacts Waste Col, Stor, & Treat Waste Application Records and Documents Other Issues Certified Operator: Paul Lewt Daw Operator Certification Number: 26042 Secondary OIC(s): On -Site Representative(s): Name Title Phone 24 hour contact name Brent Mitchell Phone : 919-738-3584 Primary Inspector: Justin K Davis Phone: Inspector Signature: Date: Secondary Inspector(s): Inspection Summary: page: 1 Permit: AWS960051 Owner - Facility : Daw Farms Inc Facility Number: 960051 Inspection Date: 08/24/16 Inppection Type: Compliance Inspection Reason for Visit: Routine Waste Report N 1 7-6-2016 1.29 3-15-2016 1.81 12-3-2015 1.24 7-29-2015 0.84 Soil Report 12/4/2015 Due 2018 Zn<407 Cu<299 Calibration 2013. Due 2017. Lagoon Sludge Survey 11-1-2016 1 LTZ= 3.3 Thickness= 3.7 Pump Intake= 3.2 off= 44 Freeboard and Rainfall records recorded on calendars. 2015 and 2016 calendars checked. page: 2 N Permit. AWS960051 Owner - Facility : Daw Farms Inc Facility Number: 960051 Inspection Date: 08/24/16 Inpsection Type: Compliance Inspection Reason for Visit: Routine Regulated Operations Design Capacity Current promotions Swine Swine - Wean to Feeder 3,200 3,050 Total Design Capacity: 3,200 Total SSLW: 96,000 Waste Structures Disignated Observed Type Identifier Closed Date Start Date Freeboard Freeboard Lagoon PRIMARY 06/01/92 19.00 29.00 page: 3 r Permit: AWS960051 Owner - Facility : Daw Farms Inc Facility Number: 960051 Inspection Date: 08/24/16 Inpsection Type: Compliance Inspection Reason for Visit: Routine Discharges & Stream Impacts Yes No Na No 1. Is any discharge observed from any part of the operation? ❑ M ❑ ❑ Discharge originated at: Structure ❑ Application Field ❑ Other ❑ a. Was conveyance man-made? ❑ 0 ❑ ❑ b. Did discharge reach Waters of the State? (if yes, notify DWQ) ❑ M ❑ ❑ c. What is the estimated volume that reached waters of the State (gallons)? d. Does discharge bypass the waste management system? (if yes, notify DWQ) ❑ 0 ❑ ❑ 2. Is there evidence of a past discharge from any part of the operation? ❑ ❑ ❑ 3. Were there any observable adverse impacts or potential adverse impacts to Waters of the ❑ 0 ❑ ❑ State other than from a discharge? Waste Collection, Storage & Treatment Yes No Na Ne 4. Is storage capacity less than adequate? ❑ M ❑ ❑ If yes, is waste level into structural freeboard? ❑ 5. Are there any immediate threats to the integrity of any of the structures observed (I.e./ large ❑ 0 ❑ ❑ trees, severe erosion, seepage, etc.)? 6. Are there structures on -site that are not properly addressed and/or managed through a ❑ 0 ❑ ❑ waste management or closure plan? 7. Do any of the structures need maintenance or improvement? ❑ 0 ❑ ❑ 8. Do any of the structures lack adequate markers as required by the permit? (Not applicable ❑ 0 ❑ ❑ to roofed pits, dry stacks and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require ❑ 0 ❑ ❑ maintenance or improvement? Waste Application Yes No Na No 10. Are there any required buffers, setbacks, or compliance alternatives that need ❑ M ❑ ❑ maintenance or improvement? 11. Is there evidence of incorrect application? ❑ M ❑ ❑ If yes, check the appropriate box below. Excessive Ponding? ❑ Hydraulic Overload? ❑ Frozen Ground? ❑ Heavy metals (Cu, Zn, etc)? ❑ PAN? ❑ Is PAN > 10%/10 lbs.? ❑ Total Phosphorus? ❑ Failure to incorporate manure/sludge into bare soil? ❑ Outside of acceptable crop window? ❑ Evidence of wind drift? ❑ Application outside of application area? ❑ page: 4 • •. Permit: AWS960051 Owner -Facility: Daw Fanns Inc Facility Number: 960051 Inspection Date: 08/24/16 Inpsection Type: Compliance Inspection Reason for Visit: Routine Waste Application Yes No Na Ne Crop Type 1 Crop Type 2 Crop Type 3 Crop Type 4 Crop Type 5 Crop Type 6 Soil Type 1 Soil Type 2 Soil Type 3 Soil Type 4 Soil Type 5 Soil Type 6 14. Do the receiving crops differ from those designated in the Certified Animal Waste ❑ 0 ❑ ❑ Management Plan(CAWMP)? 15. Does the receiving crop and/or land application site need improvement? ❑ MEI ❑ 16. Did the facility fail to secure and/or operate per the irrigation design or wettable acre ❑ MEI ❑ determination? 17. Does the facility lack adequate acreage for land application? ❑ ❑ ❑ 18. Is there a lack of properly operating waste application equipment? ❑ 0 ❑ ❑ Records and Documents Yes No Na Ne 19. Did the facility fail to have Certificate of Coverage and Permit readily available? ❑ ❑ ❑ 20. Does the facility fail to have all components of the CAWMP readily available? ❑ 0 ❑ ❑ If yes, check the appropriate box below WUP? ❑ Checklists? ❑ Design? ❑ Maps? ❑ Lease Agreements? ❑ Other? ❑ If Other, please specify 21. Does record keeping need improvement? ❑ M ❑ ❑ If yes, check the appropriate box below. Waste Application? ❑ Weekly Freeboard? ❑ Waste Analysis? ❑ Soil analysis? ❑ Waste Transfers? ❑ Weather code? ❑ Rainfall? ❑ Stocking? ❑ page: 5 Permit: AWS960051 Owner - Facility : Daw Farms Inc Facility Number: 960051 Inspection Date: 08/24/16 Inpsection Type: Compliance Inspection Reason for Visit: Routine Records and Documents Yes No Na Ne Crop yields? ❑ 120 Minute inspections? ❑ Monthly and 1" Rainfall Inspections ❑ Sludge Survey ❑ 22. Did the facility fail to install and maintain a rain gauge? ❑ ❑ ❑ 23. If selected, did the facility fail to install and maintain a rainbreaker on irrigation equipment ❑ 0 ❑ ❑ (NPDES only)? 24. Did the facility fail to calibrate waste application equipment as required by the permit? ❑ N ❑ ❑ 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check the ❑ 0 ❑ ❑ appropriate box(es) below: Failure to complete annual sludge survey ❑ Failure to develop a POA for sludge levels ❑ Non -compliant sludge levels in any lagoon ❑ List structure(s) and date of first survey indicating non-compliance: 26. Did the facility fail to provide documentation of an actively certified operator in charge? ❑ 0 ❑ ❑ 2?. Did the facility fail to secure a phosphorous loss assessment (PLAT) certification? ❑ N ❑ ❑ Other Issues Yes No Na Ne 28. Did the facility fail to properly dispose of dead animals within 24 hours and/or document ❑ 0 ❑ ❑ and report mortality rates that exceed normal rates? 29. At the time of the inspection did the facility pose an odor or air quality concern? If yes, ❑ 0 ❑ ❑ contact a regional Air Quality representative immediately. 30. Did the facility fail to notify regional DWQ of emergency situations as required by Permit? ❑ 0 ❑ ❑ (i.e., discharge, freeboard problems, over -application) 31. Do subsurface tile drains exist at the facility? ❑ E ❑ ❑ If yes, check the appropriate box below. Application Field ❑ Lagoon / Storage Pond ❑ Other ❑ If Other, please specify 32. Were any additional problems noted which cause non-compliance of the Permit or ❑ E ❑ ❑ CAWMP? 33. Did the Reviewer/Inspector fail to discuss review/inspection with on -site representative? ❑ 0 ❑ ❑ 34. Does the facility require a follow-up visit by same agency? ❑ E ❑ ❑ page: 6 0 Division of Water Resources Division of Soil and Water Conservation El Other Agency Facility Number: 960051 Facility Status: Active Permit: AWS960051 ❑ Denied Access Inpsection Type: Compliance Inspection Reason for Visit: Routine Dale of Visit: 09/17/2015 Entry Time: 08:40 am Farm Name: Daw & Son Farm Owner: Daw Farms Inc Mailing Address: 653 Hare Rd Physical Address: 1041 Mt Carmel Church Rd Facility Status: ® Compliant ❑ Not Compliant Location of Farm: SR 1545, 2 miles north of SR 1523, west side of road. Question Areas: K] Dischrge & Stream Impacts 10 Records and Documents Inactive Or Closed Date: County: Wayne Region: Washington Exit Time: 9:50 am Incident # Owner Email: Phone: 919-734-6410 Goldsboro NC 27534 Pikeville NC 27863 Integrator: Maxwell Foods Inc Latitude: 35' 28' 25" Longitude: 77' 56' 36" Waste Col, Stor, & Treat Other Issues Waste Application Certified Operator: Paul Lewt Daw Operator Certification Number: 26042 Secondary OIC(s): On -Site Representative(s): Name Title Phone 24 hour contact name Brent Mitchell Phone: 919-738-3584 Primary Inspector: Inspector Signature: Secondary Inspector(s): Inspection Summary: Justin K Davis Phone: Date: page: 1 Permit: AWS960051 Owner - Facility : Daw Farms Inc Facility Number: 960051 Inspection Date: 09/17/15 Inpsection Type: Compliance Inspection Reason for Visit: Routine Waste Report N 7-29-15 0.84 4-21-15 1.46 2-4-15 1.18 12-3-14 1.86 8-1-14 1.29 Soil Report Zn<420 Cu<280 Lagoon Sludge Survey 5-16-14 LTZ-3.9 Thickness-3.3 Pump Intake-3.9 37% Calibration due 2015. Crop yield, pumping records, rainfall and freeboard coincide. page: 2 Permit: AWS960051 Owner - Facility : Daw Farms Inc Facility Number: 960051 Inspection Date: 09/17/15 Inpsection Type. Compliance Inspection Reason for Visit: Routine Regulated Operations Design Capacity Current promotions Swine El Swine - Wean to Feeder 3,200 I 3,418 Total Design Capacity: 3,200 Total SSLW: 96,000 Waste Structures Disignated Observed Type Identifier Closed Date Start Date Freeboard Freeboard Lagoon PRIMARY 06/01/92 19.00 38.00 page: 3 Permit: AWS960051 Owner - Facility : Daw Farms Inc Facility Number: 960051 Inspection Date: 09/17/15 Inpsection Type: Compliance Inspection Reason for Visit: Routine Discharges & Stream Impacts Yes No Na Ne 1. Is any discharge observed from any part of the operation? ❑ ®❑ ❑ Discharge originated at: Structure ❑ Application Field ❑ Other ❑ a. Was conveyance man-made? ❑ ®❑ ❑ b. Did discharge reach Waters of the State? (if yes, notify DWQ) ❑ M ❑ ❑ c. What is the estimated volume that reached waters of the State (gallons)? d. Does discharge bypass the waste management system? (if yes, notify DWQ) ❑ ®❑ ❑ 2. Is there evidence of a past discharge from any part of the operation? ❑ ®❑ ❑ 3. Were there any observable adverse impacts or potential adverse impacts to Waters of the ❑ ®❑ ❑ State other than from a discharge? Waste Collection, Storage & Treatment Yes No Na No 4. Is storage capacity less than adequate? ❑ ®❑ ❑ If yes, is waste level into structural freeboard? ❑ 5. Are there any immediate threats to the integrity of any of the structures observed (I.e./ large ❑ ®❑ ❑ trees, severe erosion, seepage, etc.)? 6. Are there structures on -site that are not properly addressed and/or managed through a ❑ ®❑ ❑ waste management or closure plan? 7. Do any of the structures need maintenance or improvement? ❑ ®❑ ❑ 8. Do any of the structures lack adequate markers as required by the permit? (Not applicable ❑ ®❑ ❑ to roofed pits, dry stacks and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require ❑ ®❑ ❑ maintenance or improvement? Waste Application Yes No Na Ne 10. Are there any required buffers, setbacks, or compliance alternatives that need ❑ ®❑ ❑ maintenance or improvement? 11. Is there evidence of incorrect application? ❑ ®❑ ❑ If yes, check the appropriate box below. Excessive Ponding? ❑ Hydraulic Overload? ❑ Frozen Ground? ❑ Heavy metals (Cu, Zn, etc)? ❑ PAN? ❑ Is PAN > 10%/10 lbs.? ❑ Total Phosphorus? ❑ Failure to incorporate manure/sludge into bare soil? ❑ Outside of acceptable crop window? ❑ Evidence of wind drift? ❑ Application outside of application area? ❑ page: 4 Permit: AWS960051 Owner - Facility : Daw Farms Inc Facility Number: 960051 Inspection Date: 09/17/15 Inpsection Type: Compliance Inspection Reason for Visit: Routine Waste Application Yes No Na Ne Crop Type 1 Crop Type 2 Crop Type 3 Crop Type 4 Crop Type 5 Crop Type 6 Soil Type 1 Soil Type 2 Soil Type 3 Soil Type 4 Soil Type 5 Soil Type 6 14. Do the receiving crops differ from those designated in the Certified Animal Waste ❑ ®❑ ❑ Management Plan(CAWMP)? 15. Does the receiving crop and/or land application site need improvement? ❑ ®❑ ❑ 16. Did the facility fail to secure and/or operate per the irrigation design or wettable acre ❑ . ❑ ❑ determination? 17. Does the facility lack adequate acreage for land application? ❑ ®❑ ❑ 18. Is there a lack of properly operating waste application equipment? ❑ ®❑ ❑ Records and Documents Yes No Na No 19. Did the facility fail to have Certificate of Coverage and Permit readily available? ❑ ®❑ ❑ 20. Does the facility fail to have all components of the CAWMP readily available? ❑ W ❑ ❑ If yes, check the appropriate box below. WUP? ❑ Checklists? ❑ Design? ❑ Maps? ❑ Lease Agreements? ❑ Other? ❑ If Other, please specify 21. Does record keeping need improvement? ❑ N ❑ ❑ If yes, check the appropriate box below. Waste Application? ❑ Weekly Freeboard? ❑ Waste Analysis? ❑ Soil analysis? ❑ Waste Transfers? ❑ Weather code? ❑ Rainfall? ❑ Stocking? ❑ page: 5 Permit: AWS960051 Owner - Facility : Daw Farms Inc Facility Number: 960051 Inspection Date: 09/17/15 Inpsection Type: Compliance Inspection Reason for Visit: Routine Records and Documents Yes No Na Ne Crop yields? ❑ 120 Minute inspections? ❑ Monthly and 1" Rainfall Inspections ❑ Sludge Survey ❑ 22. Did the facility fail to install and maintain a rain gauge? ❑ ®❑ ❑ 23. If selected, did the facility fail to install and maintain a rainbreaker on irrigation equipment ❑ ©❑ ❑ (NPDES only)? 24. Did the facility fail to calibrate waste application equipment as required by the permit? ❑ ®❑ ❑ 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check the ❑ ®❑ ❑ appropriate box(es) below: Failure to complete annual sludge survey ❑ Failure to develop a POA for sludge levels ❑ Non -compliant sludge levels in any lagoon ❑ List structure(s) and date of first survey indicating non-compliance: 26. Did the facility fail to provide documentation of an actively certified operator in charge? ❑ ®❑ ❑ 27. Did the facility fail to secure a phosphorous loss assessment (PLAT) certification? ❑ ®❑ ❑ Other Issues Yes No Na Ne 28. Did the facility fail to properly dispose of dead animals within 24 hours and/or document ❑ ❑ ❑ ❑ and report mortality rates that exceed normal rates? 29. At the time of the inspection did the facility pose an odor or air quality concern? If yes, ❑ ❑ ❑ ❑ contact a regional Air Quality representative immediately. 30. Did the facility fail to notify regional DWQ of emergency situations as required by Permit? ❑ ❑ ❑ ❑ (i.e., discharge, freeboard problems, over -application) 31. Do subsurface tile drains exist at the facility? ❑ ❑ ❑ ❑ If yes, check the appropriate box below. Application Field ❑ Lagoon / Storage Pond ❑ Other ❑ If Other, please specify 32. Were any additional problems noted which cause non-compliance of the Permit or ❑ ❑ ❑ ❑ CAWMP? 33. Did the Reviewer/Inspector fail to discuss review/inspection with on -site representative? ❑ ❑ ❑ ❑ 34. Does the facility require a follow-up visit by same agency? ❑ ❑ ❑ ❑ page: 6 0 Division of Water Quality El Division of Soil and Water Conservation ❑ Other Agency Facility Number: 960051 Facility Status: Active Permit: AWS960051 ❑ Denied Access Inspection Type: Comoliance Inspection Inactive or Closed Date: Reason for Visit: Routine County: Wayne Region: Washington Date of Visit: 05/07/2014 Entry Time: 07:11 AM Exit Time: 07:45 AM Incident #: Farm Name: Daw & Son Farm Owner Email: Owner: Daw Farms Inc Phone: 919-734-6410 Mailing Address: 653 Hare Rd Goldsboro NC 27534 Physical Address: 1041 Mt Carmel Church Rd Pikeville NC 27863 Facility Status: E Compliant ❑ Not Compliant Integrator: Maxwell Foods Inc Location of Farm: Latitude: 35028'25" Longitude: 77056'36" SR 1545, 2 miles north of SR 1523, west side of road. Question Areas: Dischrge & Stream Impacts Waste Col, Stor, & Treat Waste Application Records and Documents Other Issues Certified Operator: Paul Lewt Daw Secondary OIC(s): Operator Certification Number: 26042 On -Site Representative(s): Name Title Phone 24 hour contact name Brent Mitchell Phone: 919-738-3584 On -site representative Brent Mitchell Phone: 919-738-3584 Primary Inspector: Ronnie T Smith Phone: Inspector Signature: Date: Secondary Inspector(s): Page: 1 Permit: AWS960051 Owner - Facility: Daw Farms Inc Facility Number: 960051 Inspection Date: 05/07/2014 Inspection Type: Compliance Inspection Reason for Visit: Routine Inspection Summary: CoC in records WUP 7111/02 OIC card in records Waste Analysis N 1 /23114 = 1.66 7/14/13 = .94 4/15/13 = 2.35 2/21/13 = 1.69 Soil Test 11/29/12 Cu & Zn levels w/in range L=OT "`due again in 2015"' crop yield reviewed "'irrgiation calibration due again 2015"` irrigation reocrds correspond to rainfall and lagoon records "Sludge Survey due again 2014"' Page: 2 Permit: AWS960051 Owner - Facility: Daw Farms Inc Facility Number: 960051 Inspection Date: 05/07/2014 Regulated Operations Inspection Type: Compliance Inspection Reason for Visit: Routine Design Capacity Current Population Swine Swine - Wean to Feeder 3,200 0 Waste Structures Type Identifier Total Design Capacity: 3,200 Total SSLW: 96,000 Designed Observed Closed Date Start Date Freeboard Freeboard agoon PRIMARY 06/01/92 19.00 39.00 Page: 3 0 Permit: AWS960051 Owner - Facility: Daw Farms Inc Facility Number: 960051 Inspection Date: 05/07/2014 Inspection Type: Compliance Inspection Reason for Visit: Routine Discharges & Stream Impacts Yes No NA NE 1. Is any discharge observed from any part of the operation? ❑ ■ ❑ ❑ Discharge originated at: Structure ❑ Application Field ❑ Other ❑ a. Was conveyance man-made? ❑ ■ ❑ ❑ b. Did discharge reach Waters of the State? (if yes, notify DWQ) ❑ ■ ❑ ❑ c. What is the estimated volume that reached waters of the State (gallons)? d. Does discharge bypass the waste management system? (if yes, notify DWQ) ❑ ■ ❑ ❑ 2. Is there evidence of a past discharge from any part of the operation? ❑ ■ ❑ ❑ 3. Were there any observable adverse impacts or potential adverse impacts to Waters of the State other than ❑ ■ ❑ ❑ from a discharge? Waste Collection, Storage & Treatment Yes No NA NE 4. Is storage capacity less than adequate? ❑ ■ ❑ ❑ If yes, is waste level into structural freeboard? ❑ 5. Are there any immediate threats to the integrity of any of the structures observed (I.e./ large trees, severe ❑ ■ ❑ ❑ erosion, seepage, etc.)? 6. Are there structures on -site that are not properly addressed and/or managed through a waste management ❑ ■ ❑ ❑ or closure plan? 7. Do any of the structures need maintenance or improvement? ❑ ■ ❑ ❑ 8. Do any of the structures lack adequate markers as required by the permit? (Not applicable to roofed pits, ❑ ■ ❑ ❑ dry stacks and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require maintenance or ❑ ■ ❑ ❑ improvement? Waste Application Yes No NA NE 10. Are there any required buffers, setbacks, or compliance alternatives that need maintenance or OSO ❑ improvement? 11. Is there evidence of incorrect application? ❑ ■ ❑ ❑ If yes, check the appropriate box below. Excessive Ponding? ❑ Hydraulic Overload? ❑ Frozen Ground? ❑ Heavy metals (Cu, Zn, etc)? ❑ Page: 4 Permit: AWS960051 Owner - Facility: Daw Fars Inc Inspection Date: 05/07/2014 Inspection Type: Compliance Inspection Facility Number: 960051 Reason for Visit: Routine Waste Application Yes No NA NE PAN? ❑ Is PAN > 10%/10 lbs.? ❑ Total Phosphorus? ❑ Failure to incorporate manure/sludge into bare soil? ❑ Outside of acceptable crop window? ❑ Evidence of wind drift? ❑ Application outside of application area? ❑ Crop Type 1 Corn, Wheat, Soybeans Crop Type 2 Crop Type 3 Crop Type 4 Crop Type 5 Crop Type 6 Soil Type 1 Craven sandy loam, 2 to 6% slopes, erode Soil Type 2 Norfolk loamy sand, 0 to 2% slopes Soil Type 3 Soil Type 4 Soil Type 5 Soil Type 6 14. Do the receiving crops differ from those designated in the Certified Animal Waste Management ❑ ■ ❑ ❑ Plan(CAWMP)? 15. Does the receiving crop and/or land application site need improvement? ❑ ■ ❑ ❑ 16. Did the facility fail to secure and/or operate per the irrigation design or wettable acre determination? ❑ ■ ❑ ❑ 17. Does the facility lack adequate acreage for land application? ❑ ■ ❑ ❑ 18. Is there a lack of properly operating waste application equipment? ❑ ■ ❑ ❑ Records and Documents Yes No NA NE 19. Did the facility fail to have Certificate of Coverage and Permit readily available? ❑ ■ ❑ ❑ 20. Does the facility fail to have all components of the CAWMP readily available? ❑ ■ ❑ ❑ If yes, check the appropriate box below Page: 5 Permit: AWS960051 Owner - Facility: Daw Farms Inc Inspection Date: 05/07/2014 Inspection Type: Compliance Inspection Records and Documents Facility Number: 960051 Reason for Visit: Routine WUP? ❑ Checklists? ❑ Design? ❑ Maps? ❑ Lease Agreements? ❑ Other? ❑ If Other, please specify 21. Does record keeping need improvement? OMOO If yes, check the appropriate box below. Waste Application? ❑ Weekly Freeboard? ❑ Waste Analysis? ❑ Soil analysis? ❑ Waste Transfers? ❑ Weather code? ❑ Rainfall? ❑ Stocking? ❑ Crop yields? ❑ 120 Minute inspections? ❑ Monthly and 1" Rainfall Inspections ❑ Sludge Survey ❑ 22. Did the facility fail to install and maintain a rain gauge? ❑ ■ ❑ ❑ 23. If selected, did the facility fail to install and maintain a rainbreaker on irrigation equipment (NPDES only)? ❑ ■ ❑ ❑ 24. Did the facility fail to calibrate waste application equipment as required by the permit? ❑ ■ ❑ ❑ 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check the appropriate ❑ ■ ❑ ❑ box(es) below: Failure to complete annual sludge survey ❑ Failure to develop a POA for sludge levels ❑ Non -compliant sludge levels in any lagoon ❑ List structure(s) and date of first survey indicating non-compliance: Page: 6 u Permit: AWS960051 Owner - Facility: Daw Farms Inc Inspection Date: 05/07/2014 Inspection Type: Compliance Inspection Facility Number: 960051 Reason for Visit: Routine Records and Documents Yes No NA NE 26. Did the facility fail to provide documentation of an actively certified operator in charge? ONO ❑ 27. Did the facility fail to secure a phosphorous loss assessment (PLAT) certification? ❑ ■ ❑ ❑ Other Issues Yes No NA NE 28. Did the facility fail to properly dispose of dead animals within 24 hours and/or document and report ❑ ■ ❑ ❑ mortality rates that exceed normal rates? 29. At the time of the inspection did the facility pose an odor or air quality concern? If yes, contact a regional ❑ ■ ❑ ❑ Air Quality representative immediately. 30. Did the facility fail to notify regional DWQ of emergency situations as required by Permit? (i.e., discharge, ❑ ■ ❑ ❑ freeboard problems, over -application) 31. Do subsurface tile drains exist at the facility? ❑ ■ ❑ ❑ If yes, check the appropriate box below. Application Field Lagoon / Storage Pond Other If Other, please specify 32. Were any additional problems noted which cause non-compliance of the Permit or CAWMP? 33. Did the Reviewer/Inspector fail to discuss review/inspection with on -site representative? 34. Does the facility require a follow-up visit by same agency? IS Page: 7 F% J Division of Water Quality j� Division of Soil and Water Conservation ❑ Other Agency Facility Number: 960051 Facility Status: Active Permit: AWS960051 ❑ Denied Access Inspection Type: Compliance Inspection Inactive or Closed Date: Reason for Visit: Routine County: Wayne Region: Washington Date of Visit: 08/06/2013 Entry Time: 12:30 PM Exit Time: 01:10 PM Incident #: Farm Name: Daw & Son Farm Owner Email: Owner: Daw Farms Inc Phone: 919-734-6410 Mailing Address: 653 Hare Rd Goldsboro NC 27534 Physical Address: 1041 Mt Carmel Church Rd Pikeville NC 27863 Facility Status: 0 Compliant ❑ Not Compliant Integrator: Maxwell Foods Inc Location of Farm: Latitude: 35°28'25" Longitude: 77056'36" SR 1545, 2 miles north of SR 1523, west side of road Question Areas: Dischrge & Stream Impacts Waste Col, Stor, & Treat Waste Application Records and Documents Other Issues Certified Operator: Paul Lewt Daw Operator Certification Number: 26042 Secondary OIC(s): On -Site Representative(s): Name Title Phone 24 hour contact name Brent Mitchell Phone: 919-738-3584 On -site representative Brent Mitchell Phone: 919-738-3584 Primary Inspector: Ronnie T Smith Phone: Inspector Signature: Date: Secondary Inspector(s): Page: 1 Permit: AWS960051 Owner - Facility: Daw Farms Inc Facility Number: 960051 Inspection Date: 08/0612013 Inspection Type: Compliance Inspection Reason for Visit: Routine Inspection Summary: WuP 7111112 OIC in records Waste Analysis N 7/14/13 = .94 4/15/13 = 2.35 2/21/13 = 1.69 10/15/12 = 1.11 crop yield records reviewed Soil Test 11/29/12 L = O.OT Cu & Zn levels "due again 2013" sludge Survey 10/23/12 thickness = 1.9 LTZ = 5.4 pump intake = 3.4 19% Irrigation calibration due again 2013" irrigation records correspond to rainfall and lagoon records Page: 2 Permit: AWS960051 Owner - Facility: Dew Farms Inc Facility Number: 960051 Inspection Date: 08/06/2013 Inspection Type: Compliance Inspection Reason for Visit: Routine Regulated Operations Design Capacity Current Population Swine Q Swine - Wean to Feeder 3,200 2,870 Waste Structures Type Identifier Total Design Capacity: 3,200 Total SSLW: 96,000 Designed Observed Closed Date Start Date Freeboard Freeboard lagoon PRIMARY 06/01/92 19.00 38.00 Page: 3 Permit: AWS960051 Owner - Facility: Daw Farms Inc Facility Number: 960051 Inspection Date: 08/06/2013 Inspection Type: Compliance Inspection Reason for Visit: Routine Discharges & Stream Impacts Yes No NA NE 1. Is any discharge observed from any part of the operation? ❑ ■ ❑ ❑ Discharge originated at: Structure ❑ Application Field ❑ Other ❑ a. Was conveyance man-made? ❑ ■ ❑ ❑ b. Did discharge reach Waters of the State? (if yes, notify DWQ) ❑ ■ ❑ ❑ c. What is the estimated volume that reached waters of the State (gallons)? d. Does discharge bypass the waste management system? (if yes, notify DWQ) ❑ ■ ❑ ❑ 2. Is there evidence of a past discharge from any part of the operation? ❑ ■ ❑ ❑ 3. Were there any observable adverse impacts or potential adverse impacts to Waters of the State other than ❑ ■ ❑ ❑ from a discharge? Waste Collection, Storage & Treatment Yes No NA NE 4. Is storage capacity less than adequate? ❑ ■ ❑ ❑ If yes, is waste level into structural freeboard? ❑ 5. Are there any immediate threats to the integrity of any of the structures observed (I.e./ large trees, severe ❑ ■ ❑ ❑ erosion, seepage, etc.)? 6. Are there structures on -site that are not properly addressed and/or managed through a waste management ❑ ■ ❑ ❑ or closure plan? 7. Do any of the structures need maintenance or improvement? ❑ ■ ❑ ❑ 8. Do any of the structures lack adequate markers as required by the permit? (Not applicable to roofed pits, ❑ ■ ❑ ❑ dry stacks and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require maintenance or ❑ ■ ❑ ❑ improvement? Waste Application Yes No NA NE 10. Are there any required buffers, setbacks, or compliance alternatives that need maintenance or ❑ ■ ❑ ❑ improvement? 11. Is there evidence of incorrect application? ❑ ■ ❑ ❑ If yes, check the appropriate box below. Excessive Ponding? ❑ Hydraulic Overload? ❑ Frozen Ground? ❑ Heavy metals (Cu, Zn, etc)? ❑ Page: 4 Permit: AWS960051 Owner • Facility: Daw Farms Inc Inspection Date: 08/06/2013 Inspection Type: Compliance Inspection Facility Number : 960051 Reason for Visit: Routine Waste Application Yes No NA NE PAN? ❑ Is PAN > 10%/10 lbs.? ❑ Total Phosphorus? ❑ Failure to incorporate manure/sludge into bare soil? ❑ Outside of acceptable crop window? ❑ Evidence of wind drift? ❑ Application outside of application area? ❑ Crop Type 1 Corn, Wheat, Soybeans Crop Type 2 Crop Type 3 Crop Type 4 Crop Type 5 Crop Type 6 Soil Type 1 Craven sandy loam, 2 to 6% slopes, erode Soil Type 2 Norfolk loamy sand, 0 to 2% slopes Soil Type 3 Soil Type 4 Soil Type 5 Soil Type 6 14. Do the receiving crops differ from those designated in the Certified Animal Waste Management ❑ ■ ❑ ❑ Plan(CAWMP)? 15. Does the receiving crop and/or land application site need improvement? 000 ❑ 16. Did the facility fail to secure and/or operate per the irrigation design or wettable acre determination? ❑ ■ ❑ ❑ 17. Does the facility lack adequate acreage for land application? ❑ ■ ❑ ❑ 18. Is there a lack of properly operating waste application equipment? ONO ❑ Records and Documents Yes No NA NE 19. Did the facility fail to have Certificate of Coverage and Permit readily available? ❑ ■ ❑ ❑ 20. Does the facility fail to have all components of the CAWMP readily available? ❑ ■ ❑ ❑ If yes, check the appropriate box below Page: 5 Permit: AWS960051 Owner - Facility: Daw Farms Inc Facility Number; 960051 Inspection Date: 0810612013 Inspection Type: Compliance Inspection Reason for Visit: Routine Records and Documents Yes No NA NE WUP? ❑ Checklists? ❑ Design? ❑ Maps? ❑ Lease Agreements? ❑ Other? ❑ If Other, please specify 21. Does record keeping need improvement? If yes, check the appropriate box below. Waste Application? ❑ Weekly Freeboard? ❑ Waste Analysis? ❑ Soil analysis? ❑ Waste Transfers? ❑ Weather code? ❑ Rainfall? ❑ Stocking? ❑ Crop yields? ❑ 120 Minute inspections? ❑ Monthly and 1" Rainfall Inspections ❑ Sludge Survey ❑ 22. Did the facility fail to install and maintain a rain gauge? ❑ ■ ❑ ❑ 23. If selected, did the facility fail to install and maintain a rainbreaker on irrigation equipment (NPDES only)? ❑ ■ ❑ ❑ 24. Did the facility fail to calibrate waste application equipment as required by the permit? ❑ ■ ❑ ❑ 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check the appropriate ❑ ■ ❑ ❑ box(es) below: Failure to complete annual sludge survey ❑ Failure to develop a PDA for sludge levels ❑ Non -compliant sludge levels in any lagoon ❑ List structure(s) and date of first survey indicating non-compliance: Page: 6 Permit: AWS960051 Owner - Facility: Daw Farms Inc Inspection Date: 08/06/2013 Inspection Type: Compliance Inspection Facility Number: 960051 Reason for Visit: Routine Records and Documents Yes No NA NE 26. Did the facility fail to provide documentation of an actively certified operator in charge? ❑ ■ ❑ ❑ 27. Did the facility fail to secure a phosphorous loss assessment (PLAT) certification? ❑ ■ ❑ ❑ Other Issues Yes No NA NE 28. Did the facility fail to properly dispose of dead animals within 24 hours and/or document and report ❑ ■ ❑ ❑ mortality rates that exceed normal rates? 29. At the time of the inspection did the facility pose an odor or air quality concern? If yes, contact a regional ❑ ■ ❑ ❑ Air Quality representative immediately. 30. Did the facility fail to notify regional DWQ of emergency situations as required by Permit? (i.e., discharge, ❑ ■ ❑ ❑ freeboard problems, over -application) 31. Do subsurface tile drains exist at the facility? ❑ ■ ❑ ❑ If yes, check the appropriate box below. Application Field Lagoon / Storage Pond Other If Other, please specify 32. Were any additional problems noted which cause non-compliance of the Permit or CAWMP? 33. Did the Reviewer/Inspector fail to discuss review/inspection with on -site representative? 34. Does the facility require a follow-up visit by same agency? Page: 7 Division of Water Quality ❑ Division of Soil and Water Conservation ❑ Other Agency Facility Number: 960051 Facility Status: Active Permit: AWS960051 ❑ Denied Access Inspection Type: Comoliance Inspection Inactive or Closed Date: Reason for Visit: Routine County: Wayne Region: Washington Date of Visit: 05/22/2012 Entry Time: 08:57 AM Exit Time: 09:30 AM Incident #: Farm Name: Daw & Son Farm Owner Email: Owner: paw Farms Inc Phone: 919-734-6410 Mailing Address: 653 Hare Rd Goldsboro NC 27534 Physical Address: 1041 Mt Carmel Church Rd Pikeville NC 27863 Facility Status: 0 Compliant ❑ Not Compliant Integrator: Maxwell Foods Inc Location of Farm: Latitude: 35028'25" Longitude: 77956'36" SR 1545, 2 miles north of SR 1523, west side of road Question Areas: Dischrge & Stream Impacts Waste Col, Stor, & Treat Waste Application Records and Documents Other Issues Certified Operator: Paul Lewt Daw Operator Certification Number: 26042 Secondary OIC(s): On -Site Representative(s): Name Title Phone 24 hour contact name Brent Mitchell Phone: 919-738-3584 On -site representative Brent Mitchell Phone: 919-738-3584 Primary Inspector: Ronnie T Smith Phone: Inspector Signature: Date: Secondary Inspector(s): Page: 1 Permit: AWS960051 Owner - Facility: Daw Farms Inc Facility Number: 960051 Inspection Date: 05/22/2012 Inspection Type: Compliance Inspection Reason for Visit: Routine Inspection Summary: New CoC in records WUP 7/11/02 OIC card in records Sludge Survey 8/10/11 "due again 2012" thickness = 1.1 LTZ = 5.7 pump intake = 3.8 12% Waste Analysis N 3/8/12 = 2.4 12/1111 = 1.4 7/13/11 = 2.2 Soil Test 12/1/2011 "due again 2012" Cu & Zn levels Min range L=OT irrigation records correspond to rainfall & lagoon records irrigation calibration 9/19/11 "due again 2013" crop yield records reveiwed Page: 2 Permit: AWS960051 Owner - Facility: Daw Farms Inc Inspection Date: 05/22/2012 Inspection Type: Compliance Inspection Facility Number: 960051 Reason for Visit: Routine Regulated Operations Design Capacity Current Population Swine Swine - Wean to Feeder 3,200 2,374 Total Design Capacity: 3,200 Total SSLW: 96,000 Waste Structures Designed Observed Type Identifier Closed Date Start Date Freeboard Freeboard agoon PRIMARY O6/01/92 19.00 37.00 Page: 3 Permit: AWS960051 Owner - Facility: Daw Farms Inc Facility Number: 960051 Inspection Date: 05/22/2012 Inspection Type: Compliance Inspection Reason for Visit: Routine Discharges & Stream Impacts Yes No NA NE 1. Is any discharge observed from any part of the operation? ❑ ■ ❑ ❑ Discharge originated at: Structure ❑ Application Field ❑ Other ❑ a. Was conveyance man-made? ❑ ■ ❑ ❑ b. Did discharge reach Waters of the State? (if yes, notify DWQ) ❑ ■ ❑ ❑ c. What is the estimated volume that reached waters of the State (gallons)? d. Does discharge bypass the waste management system? (if yes, notify DWQ) ❑ ■ ❑ ❑ 2. Is there evidence of a past discharge from any part of the operation? ❑ ■ ❑ ❑ I Were there any observable adverse impacts or potential adverse impacts to Waters of the State other than ❑ ■ ❑ ❑ from a discharge? Waste Collection, Storage & Treatment Yes No NA NE 4. Is storage capacity less than adequate? ❑ ■ ❑ ❑ If yes, is waste level into structural freeboard? ❑ 5. Are there any immediate threats to the integrity of any of the structures observed (I.e./ large trees, severe ❑ ■ ❑ ❑ erosion, seepage, etc.)? 6. Are there structures on -site that are not properly addressed and/or managed through a waste management ❑ ■ ❑ Cl or closure plan? 7. Do any of the structures need maintenance or improvement? ❑ ■ ❑ ❑ 8. Do any of the structures lack adequate markers as required by the permit? (Not applicable to roofed pits, ❑ ■ ❑ ❑ dry stacks and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require maintenance or ❑ ■ ❑ Cl improvement? Waste Application Yes No NA NE 10. Are there any required buffers, setbacks, or compliance alternatives that need maintenance or ❑ ■ ❑ ❑ improvement? 11. Is there evidence of incorrect application? ❑ ■ ❑ ❑ If yes, check the appropriate box below. Excessive Ponding? ❑ Hydraulic Overload? ❑ Frozen Ground? ❑ Heavy metals (Cu, Zn, etc)? ❑ Page: 4 Permit: AWS960051 Owner • Facility: Daw Farms Inc Inspection Date: 05122/2012 Inspection Type: Compliance Inspection Facility Number: 960051 Reason for Visit: Routine Waste Application Yes No NA NE PAN? ❑ Is PAN > 10%/10 lbs.? ❑ Total Phosphorus? ❑ Failure to incorporate manure/sludge into bare soil? ❑ Outside of acceptable crop window? ❑ Evidence of wind drift? ❑ Application outside of application area? ❑ Crop Type 1 Corn, Wheat, Soybeans Crop Type 2 Crop Type 3 Crop Type 4 Crop Type 5 Crop Type 6 Soil Type 1 Craven sandy loam, 2 to 6% slopes, erode Soil Type 2 Craven Soil Type 3 Norfolk loamy sand, 0 to 2% slopes Soil Type 4 Soil Type 5 Soil Type 6 14. Do the receiving crops differ from those designated in the Certified Animal Waste Management ❑ ■ ❑ ❑ Plan(CAWMP)? 15. Does the receiving crop and/or land application site need improvement? ❑ ■ ❑ ❑ 16. Did the facility fail to secure and/or operate per the irrigation design or wettable acre determination? ❑ ■ ❑ ❑ 17. Does the facility lack adequate acreage for land application? ONO ❑ 16. Is there a lack of properly operating waste application equipment? ❑ ■ ❑ ❑ Records and Documents Yes No NA NE 19. Did the facility fail to have Certificate of Coverage and Permit readily available? ❑ ■ ❑ ❑ 20. Does the facility fail to have all components of the CAWMP readily available? ❑ ■ ❑ ❑ If yes, check the appropriate box below Page: 5 Permit: AWS960051 Owner - Facility: Daw Farms Inc Facility Number: 960051 Inspection Date: 05/22/2012 Inspection Type: Compliance Inspection Reason for Visit: Routine Records and Documents Yes No NA NE WUP? ❑ Checklists? ❑ Design? ❑ Maps? ❑ Lease Agreements? ❑ Other? ❑ If Other, please specify 21. Does record keeping need improvement? ❑ ■ ❑ ❑ If yes, check the appropriate box below. Waste Application? ❑ Weekly Freeboard? ❑ Waste Analysis? ❑ Soil analysis? ❑ Waste Transfers? ❑ Weather code? ❑ Rainfall? ❑ Stocking? ❑ Crop yields? ❑ 120 Minute inspections? ❑ Monthly and 1" Rainfall Inspections ❑ Sludge Survey ❑ 22. Did the facility fail to install and maintain a rain gauge? ❑ ■ ❑ ❑ 23. If selected, did the facility fail to install and maintain a rainbreaker on irrigation equipment (NPDES only)? ❑ ■ ❑ ❑ 24. Did the facility fail to calibrate waste application equipment as required by the permit? ❑ ■ ❑ ❑ 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check the appropriate ❑ ■ ❑ ❑ box(es) below: Failure to complete annual sludge survey ❑ Failure to develop a POA for sludge levels ❑ Non -compliant sludge levels in any lagoon ❑ List structure(s) and date of first survey indicating non-compliance: Page: 6 Permit: AWS960051 Owner - Facility: Daw Farms Inc Facility Number: 960051 Inspection Date: 05/22/2012 Inspection Type: Compliance Inspection Reason for Visit: Routine Records and Documents Yes No NA NE 26. Did the facility fail to provide documentation of an actively certified operator in charge? 27. Did the facility fail to secure a phosphorous loss assessment (PLAT) certification? ❑ ■ ❑ ❑ Otherlssues Yes No NA NE 28. Did the facility fail to properly dispose of dead animals within 24 hours and/or document and report ❑ ■ ❑ ❑ mortality rates that exceed normal rates? 29. At the time of the inspection did the facility pose an odor or air quality concern? If yes, contact a regional ❑ ■ ❑ ❑ Air Quality representative immediately. 30. Did the facility fail to notify regional DWQ of emergency situations as required by Permit? (i.e., discharge, ❑ ■ ❑ ❑ freeboard problems, over -application) 31. Do subsurface tile drains exist at the facility? ❑ ■ ❑ ❑ If yes, check the appropriate box below. Application Field ❑ Lagoon / Storage Pond ❑ Other ❑ If Other, please specify 32. Were any additional problems noted which cause non-compliance of the Permit or CAWMP? ❑ ■ ❑ ❑ 33. Did the Reviewer/Inspector fail to discuss review/inspection with on -site representative? ❑ ■ ❑ ❑ 34. Does the facility require a follow-up visit by same agency? ❑ ■ ❑ ❑ Page: 7 Division of Water Quality Division of Soil and Water Conservation ❑ Other Agency Facility Number: 960051 Facility Status: Active Permit: AWS960051 ❑ Denied Access Inspection Type: Compliance Inspection Inactive or Closed Date: Reason for Visit: Routine County: Wayne Region: Washington Date of Visit: 07/11/2011 Entry Time:09:30 AM Exit Time: 10:15 AM Incident #: Farm Name: Daw & Son Farm Owner Email: Owner: Daw Farms Inc Phone: 919-734-6410 Mailing Address: 653 Hare Rd Goldsboro NC 27534 Physical Address: 1041 Mt Cannel Church Rd Pikeville NC 27863 Facility Status: E Compliant ❑ Not Compliant Integrator: Maxwell Foods Inc Location of Farm: Latitude: 35028'25" Longitude: 77°56'36" SR 1545, 2 miles north of SR 1523, west side of road. Question Areas: Discharges & Stream Impacts Waste Collection & Treatment Waste Application Records and Documents Other Issues Certified Operator: Paul Lewt Daw Secondary OIC(s): Operator Certification Number: 26042 On -Site Representative(s): Name Title Phone 24 hour contact name Brent Mitchell Phone: 919-738-3584 On -site representative Brent Mitchell Phone: 919-738-3584 Primary Inspector: Ronnie T Smith Phone: Inspector Signature: Date: Secondary Inspector(s): Page:1 Permit: AWS960051 Owner - Facility: Daw Farms Inc Facility Number: 960051 Inspection Date: 07/11/2011 Inspection Type: Compliance Inspection Reason for Visit: Routine Inspection Summary: WUP 7/11/02 Soil Test 11/8/10 CoC in records "due again in 2011" OIC in records Field #2 & Field #4 Zn levels around 1,000 keep eye on, Cu w/in range. Waste Analysis N 3/30/11 = 3.1 Sludge Survey 11/12/10 = 1.6 "due again 2011" 8/17/10 = 1.8 thickness = .8 2/15/10 = 1.6 LTZ = 4.0 pump intake = 3.8 lagoon records correspond to irrigation 13% & rainfall records. "'irrigation calibration bue again 2011 *" crop yield records reviewed Page: 2 Permit: AWS960051 Owner • Facility: Daw Farms Inc Facility Number: 960051 Inspection Date: 07/11/2011 Regulated Operations Inspection Type: Compliance Inspection Design Capacity Swine ❑ Swine - Wean to Feeder 3,200 Waste Structures Reason for Visit: Routine Current Population Total Design Capacity: 3,200 Total SSLW: 96,000 Type Identifier Closed Date Start Date Designed Freeboard Observed Freeboard agoon PRIMARY 66/01/92 1 19.00 31.00 Page: 3 Permit: AWS960051 Owner - Facility: Daw Farms Inc Inspection Date: 07/11/2011 Inspection Type: Compliance Inspection Discharges $ Stream Impacts 1. Is any discharge observed from any part of the operation? Discharge originated at: Structure Application Field Other a. Was conveyance man-made? b. Did discharge reach Waters of the State? (if yes, notify DWQ) c. What is the estimated volume that reached waters of the State (gallons)? d. Does discharge bypass the waste management system? (if yes, notify DWQ) Facility Number : 960051 Reason for Visit: Routine 2. Is there evidence of a past discharge from any part of the operation? ❑ ■ ❑ ❑ 3. Were there any observable adverse impacts or potential adverse impacts to Waters of the State other than ❑ ■ ❑ ❑ from a discharge? Waste Collection, Storage & Treatment Yes No NA NE 4. Is storage capacity less than adequate? ❑ ■ ❑ ❑ If yes, is waste level into structural freeboard? ❑ 5. Are there any immediate threats to the integrity of any of the structures observed (Le./ large trees, severe ❑ ■ ❑ ❑ erosion, seepage, etc.)? 6. Are there structures on -site that are not properly addressed and/or managed through a waste management ❑ ■ ❑ ❑ or closure plan? 7. Do any of the structures need maintenance or improvement? ❑ ■ ❑ ❑ 8. Do any of the structures lack adequate markers as required by the permit? (Not applicable to roofed pits, ❑ ■ ❑ ❑ dry stacks and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require maintenance or ❑ ■ ❑ ❑ improvement? Waste Application Yes No NA NE 10. Are there any required buffers, setbacks, or compliance alternatives that need maintenance or ❑ ■ ❑ ❑ improvement? 11. Is there evidence of incorrect application? ❑ ■ ❑ ❑ If yes, check the appropriate box below. Excessive Ponding? ❑ Hydraulic Overload? ❑ Frozen Ground? ❑ Heavy metals (Cu, Zn, etc)? ❑ Page: 4 Permit: AWS960051 Owner - Facility: Daw Farms Inc Inspection Date: 07/1112011 Inspection Type: Compliance Inspection Facility Number : 960051 Reason for Visit: Routine Waste Application Yes No NA NE PAN? ❑ - Is PAN > 10%/10 lbs.? ❑ Total Phosphorus? ❑ Failure to incorporate manure/sludge into bare soil? ❑ Outside of acceptable crop window? ❑ Evidence of wind drift? ❑ Application outside of application area? ❑ Crop Type 1 Com, Wheat, Soybeans Crop Type 2 Crop Type 3 Crop Type 4 Crop Type 5 Crop Type 6 Soil Type 1 Craven Soil Type 2 Norfolk Soil Type 3 Soil Type 4 Soil Type 5 Soil Type 6 14. Do the receiving crops differ from those designated in the Certified Animal Waste Management ❑ ■ ❑ ❑ Plan(CAWMP)? 15. Does the receiving crop and/or land application site need improvement? ❑ ■ ❑ ❑ 16. Did the facility fail to secure and/or operate per the irrigation design or wettable acre determination? ❑ ■ ❑ ❑ 17. Does the facility lack adequate acreage for land application? Cl ■ ❑ ❑ 18. Is there a lack of properly operating waste application equipment? ❑ ■ Cl ❑ Records and Documents Yes No NA NE 19. Did the facility fail to have Certificate of Coverage and Permit readily available? ❑ ■ ❑ ❑ 20. Does the facility fail to have all components of the CAWMP readily available? ❑ ■ ❑ ❑ If yes, check the appropriate box below. WUP? ❑ Page: 5 u Permit: AWS960051 Owner • Facility: Daw Farms Inc Inspection Date: 07/11/2011 Inspection Type: Compliance Inspection Records and Documents Facility Number : 960051 Reason for Visit: Routine Checklists? ❑ Design? ❑ Maps? ❑ Lease Agreements? ❑ Other? ❑ If Other, please specify 21. Does record keeping need improvement? ❑ ■ ❑ ❑ If yes, check the appropriate box below. Waste Application? ❑ Weekly Freeboard? ❑ Waste Analysis? ❑ Soil analysis? ❑ Waste Transfers? ❑ Weather code? ❑ Rainfall? ❑ Stocking? ❑ Crop yields? ❑ 120 Minute inspections? ❑ Monthly and 1" Rainfall Inspections ❑ Sludge Survey ❑ 22. Did the facility fail to install and maintain a rain gauge? ❑ ■ ❑ ❑ 23. If selected, did the facility fail to install and maintain a rainbreaker on irrigation equipment (NPDES only)? ❑ ■ ❑ ❑ 24. Did the facility fail to calibrate waste application equipment as required by the permit? ❑ ■ ❑ ❑ 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check the appropriate ❑ ■ ❑ ❑ box(es) below: Failure to complete annual sludge survey ❑ Failure to develop a POA for sludge levels ❑ Non -compliant sludge levels in any lagoon ❑ List structure(s) and date of first survey indicating non-compliance: 26. Did the facility fail to provide documentation of an actively certified operator in charge? ❑ ■ Cl ❑ Page: 6 Permit: AWS960051 Owner - Facility: Daw Farms Inc Facility Number: 960051 Inspection Date: 07/11/2011 Inspection Type: Compliance Inspection Reason for Visit: Routine Records and Documents Yes No NA NE 27. Did the facility fail to secure a phosphorous loss assessment (PLAT) certification? ❑ ■ ❑ ❑ Other Issues Yes No NA NE 28. Did the facility fail to properly dispose of dead animals within 24 hours and/or document and report ❑ ■ ❑ ❑ mortality rates that exceed normal rates? 29. At the time of the inspection did the facility pose an odor or air quality concern? If yes, contact a regional ❑ ■ ❑ ❑ Air Quality representative immediately. 30. Did the facility fail to notify regional DWQ of emergency situations as required by Permit? (i.e., discharge, ❑ ■ ❑ ❑ freeboard problems, over -application) 31. Do subsurface tile drains exist at the facility? ❑ ■ ❑ ❑ If yes, check the appropriate box below. Application Field ❑ Lagoon / Storage Pond ❑ Other ❑ If Other, please specify 32. Were any additional problems noted which cause non-compliance of the Permit or CAWMP? ❑ ■ ❑ ❑ 33. Did the Reviewer/Inspector fail to discuss reviewfinspection with on -site representative? ❑ ■ ❑ ❑ 34. Does the facility require a follow-up visit by same agency? ❑ ■ ❑ ❑ Page: 7 Division of Water Quality ❑ Division of Soil and Water Conservation ❑ Other Agency Facility Number: 960051 Facility Status: Active Permit: AWS960051 ❑ Denied Access Inspection Type: Comoliance Inspection Inactive or Closed Date: Reason for Visit: Routine County: Wayne Region: Washington Date of Visit: 09/23/2010 Entry Time:09,10 AM Exit Time: Farm Name: Daw & Son Farm Owner: paw Farms Inc Incident #: Owner Email: Phone: 919-734-6410 Mailing Address: 653 Hare Rd Goldsboro NC 27534 Physical Address: 1041 Mt Carmel Church Rd Pikeville NC 27863 Facility Status: E Compliant ❑ Not Compliant Integrator: Maxwell Foods Inc Location of Farm: SR 1545, 2 miles north of SR 1523, west side of road. Latitude:35°28'25" Longitude:77°56'36" Question Areas: Discharges & Stream Impacts Waste Collection & Treatment Waste Application Records and Documents Other Issues Certified Operator: Paul Lewt Daw Secondary OIC(s): Operator Certification Number: 26042 On -Site Representative(s): Name Title Phone 24 hour contact name Brent Mitchell Phone: 919-738-3584 On -site representative Brent Mitchell Phone: 919-738-3584 Primary Inspector: Megan H Stilley Inspector Signature: Secondary Inspector(s): Phone: Date: Page: 1 Permit: AWS960051 Owner - Facility: Daw Farms Inc Facility Number : 960051 Inspection Date: 09/23/2010 Inspection Type: Compliance Inspection Reason for Visit: Routine Inspection Summary: New COC and Permit in records Waste Analysis 8-17-10 1.8 2-15-10 1.6 11-19-09 1.2 Soil test 11-20-09 with highest lime 0 tons Cu and Zn values within range 'Sludge removed March 2010 with sludge analysis 1-28-10 13.7 -Soil test 3-8-10 with highest lime .3 tons - Cu and Zn values within range Sludge Survey 6-14-10 Thick-.8' LTZ4.0' Pump intake-3.8' 113% Sludge Ratio Calibration due 2011 } 213 GPM 6-29-09 Freeboard and Rainfall complete & correspond with irrigation Page: 2 ' Permit: AWS960051 Owner - Facility: Daw Farms Inc Inspection Date: 09/23/2010 Inspection Type: Compliance Inspection Facility Number: 960051 Reason for Visit: Routine Regulated Operations Design Capacity Current Population Swine O Swine - Wean to Feeder 3,200 2,898 Total Design Capacity: 3,200 Total SSLW: 96,000 Waste Structures Type Identifier Closed Date Start Date Designed Freeboard Observed Freeboard agoon PRIMARY 06/01/92 19.00 40.00 Page: 3 Permit: AWS960051 Owner - Facility: Daw Farms Inc Facility Number:960051 Inspection Date: 09/23/2010 Inspection Type: Compliance Inspection Reason for Visit: Routine Discharges & Stream Impacts Yes No NA NE 1. Is any discharge observed from any part of the operation? ❑ ■ ❑ ❑ Discharge originated at: Structure ❑ Application Field ❑ Other ❑ a. Was conveyance man-made? ❑ ■ ❑ ❑ b. Did discharge reach Waters of the State? (if yes, notify DWQ) ❑ ■ ❑ ❑ c. Estimated volume reaching surface waters? d. Does discharge bypass the waste management system? (if yes, notify DWQ) ❑ ■ ❑ ❑ 2. Is there evidence of a past discharge from any part of the operation? ❑ ■ ❑ ❑ 3. Were there any adverse impacts or potential adverse impacts to Waters of the State other than from a ❑ ■ ❑ ❑ discharge? Waste Collection, Storage & Treatment Yes No NA NE 4. Is storage capacity less than adequate? ❑ ■ ❑ ❑ If yes, is waste level into structural freeboard? ❑ 5. Are there any immediate threats to the integrity of any of the structures observed (I.e./ large trees, severe ❑ ■ ❑ ❑ erosion, seepage, etc.)? 6. Are there structures on -site that are not properly addressed and/or managed through a waste management ❑ ■ ❑ ❑ or closure plan? 7. Do any of the structures need maintenance or improvement? ❑ ■ ❑ ❑ 8. Do any of the structures lack adequate markers as required by the permit? (Not applicable to roofed pits, ❑ ■ ❑ ❑ dry stacks and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require maintenance or ❑ ■ ❑ ❑ improvement? Waste Application Yes No NA NE 10. Are there any required buffers, setbacks, or compliance alternatives that need maintenance or ❑ ■ ❑ ❑ improvement? 11. Is there evidence of incorrect application? ❑ ■ ❑ ❑ If yes, check the appropriate box below. Excessive Ponding? ❑ Hydraulic Overload? ❑ Frozen Ground? ❑ Heavy metals (Cu, Zn, etc)? ❑ Page: 4 Permit: AWS960051 Owner - Facility: Dew Farms Inc Inspection Date: 09/23/2010 Inspection Type: Compliance Inspection Facility Number: 960051 Reason for Visit: Routine Waste Application Yes No NA NE PAN? ❑ Is PAN > 10%/10 lbs.? ❑ Total P205? ❑ Failure to incorporate manure/sludge into bare soil? ❑ Outside of acceptable crop window? ❑ Evidence of wind drift? ❑ Application outside of application area? ❑ Crop Type 1 Com, Wheat, Soybeans Crop Type 2 Crop Type 3 Crop Type 4 Crop Type 5 Crop Type 6 Soil Type 1 Craven Soil Type 2 Norfolk Soil Type 3 Soil Type 4 Soil Type 5 Soil Type 6 14. Do the receiving crops differ from those designated in the Certified Animal Waste Management ❑ ■ ❑ ❑ Plan(CAWMP)? 15. Does the receiving crop and/or land application site need improvement? ❑ ■ ❑ ❑ 16. Did the facility fail to secure and/or operate per the irrigation design or wettable acre determination? ❑ ■ ❑ ❑ 17. Does the facility lack adequate acreage for land application? ❑ ■ ❑ ❑ 18. Is there a lack of properly operating waste application equipment? ❑ ■ ❑ ❑ Records and Documents Yes No NA NE 19. Did the facility fail to have Certificate of Coverage and Permit readily available? ❑ ■ ❑ ❑ 20. Does the facility fail to have all components of the CAWMP readily available? ❑ ■ ❑ ❑ If yes, check the appropriate box below. WUP? ❑ Page: 5 Permit: AWS960051 Owner - Facility: Daw Farms Inc Inspection Date: 09/23/2010 Inspection Type: Compliance Inspection Facility Number: 960051 Reason for Visit: Routine Records and Documents Yes No NA NE Checklists? ❑ Design? ❑ Maps? ❑ Other? ❑ 21. Does record keeping need improvement? ❑ ■ ❑ ❑ If yes, check the appropriate box below. Waste Application? ❑ 120 Minute inspections? ❑ Weather code? ❑ Weekly Freeboard? ❑ Transfers? ❑ Rainfall? ❑ Inspections after > 1 inch rainfall & monthly? ❑ Waste Analysis? ❑ Annual soil analysis? ❑ Crop yields? ❑ Stocking? ❑ Annual Certification Form (NPDES only)? ❑ 22. Did the facility fail to install and maintain a rain gauge? ❑ ■ ❑ ❑ 23. If selected, did the facility fail to install and maintain a rainbreaker on irrigation equipment (NPDES only)? ❑ ❑ ■ ❑ 24. Did the facility fail to calibrate waste application equipment as required by the permit? ❑ ■ ❑ ❑ 25. Did the facility fail to conduct a sludge survey as required by the permit? ❑ ■ ❑ ❑ 26. Did the facility fail to have an actively certified operator in charge? ❑ ■ ❑ ❑ 27: Did the facility fail to secure a phosphorous loss assessment (PLAT) certification? ❑ ❑ ■ ❑ Vas Nn NA NF 28. Were any additional problems noted which cause non-compliance of the Permit or CAWMP? ❑ ■ ❑ ❑ 29. Did the facility fail to properly dispose of dead animals within 24 hours and/or document and report those ❑ ■ ❑ ❑ mortality rates that exceed normal rates? 30. At the time of the inspection did the facility pose an air quality concern? If yes, contact a regional Air ❑ ❑ ❑ ■ Quality representative immediately. Page: 6 Permit: AWS960051 Owner - Facility: Daw Farms Inc Facility Number: 960051 Inspection Date: 09/23/2010 Otherlssues Inspection Type: Compliance Inspection 31. Did the facility fail to notify regional DWQ of emergency situations as required by Permit? 32. Did Reviewer/Inspector fail to discuss review/inspection with on -site representative? 33. Does facility require a follow-up visit by same agency? Reason for Visit: Routine Yes No NA NE ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ Page:7 E Division of Water Quality El Division of Soil and Water Conservation ❑ Other Agency Facility Number: 960051 Facility Status: Active Permit: AWS960051 ❑ Denied Access Inspection Type: Compliance Inspection Inactive or Closed Date: Reason for Visit: Routine County: Wayne Region: Washington Date of Visit: 10/07/2009 Entry Time:08730 AM Exit Time: Incident #: Farm Name: Daw & Son Farm Owner Email: Owner: Daw Farms Inc Phone: 919-734-6410 Mailing Address: 653 Hare Rd Goldsboro NC 27534 Physical Address: 1041 Mt Cannel Church Rd Pikeville NC 27863 Facility Status: 0 Compliant ❑ Not Compliant Integrator: Maxwell Foods Inc Location of Farm: Latitude: 35°28'25" Longitude: 77056'36" SR 1545, 2 miles north of SR 1523, west side of road Question Areas: Discharges & Stream Impacts Waste Collection & Treatment Waste Application Records and Documents Other Issues Certified Operator: Paul Lewt Daw Operator Certification Number: 26042 Secondary OIC(s): On -Site Representative(s): Name Title Phone 24 hour contact name Brent Mitchell Phone: 919-738-3584 On -site representative Paul Daw Phone: Primary Inspector: Megan H Stilley Phone: Inspector Signature: Date: Secondary Inspector(s): Page: 1 Permit: AWS960051 Owner - Facility: Daw Farms Inc Facility Number: 960051 Inspection Date: 10/07/2009 Inspection Type: Compliance Inspection Reason for Visit: Routine Inspection Summary: COC and Permit in records 2014 Waste Analysis 8-12-09 .88 2-4-09 1.6 11-17-08 1.6 7)Leak at pump by lagoon - maintain - looks like past leak Soil test 12-19-08 with highest lime 0 tons -Zinc levels elevated on field 2&3 (levels in the 1000 range) Freeboard and Rainfall complete and correspond with irrigation Calibration 6-29-09 with 213 GPM ) Next one due 2011 Sludge Survey 2-23-09 Thick-3.2' LTZ-3.4' Pump intake-2.6') Sludge Ratio 40% Crop yield complete Page:2 Permit: AWS960051 Owner - Facility: Daw Farms Inc Facility Number: 960051 Inspection Date: 10/07/2009 Inspection Type: Compliance Inspection Reason for Visit: Routine Regulated Operations Design Capacity Current Population Swine O swine - Wean to Feeder 3,200 2,791 Total Design Capacity: 3,200 Total SSLW: 96,000 Waste Structures Type Identifier Closed Date Start Date Designed Freeboard Observed Freeboard agoon PRIMARY 06/01/92 19.00 30.00 Page: 3 Permit: AWS960051 Owner - Facility: Daw Farms Inc Facility Number: 960051 Inspection Date: 10/07/2009 Inspection Type: Compliance Inspection Reason for Visit: Routine Discharges & Stream Impacts Yes No NA NE 1. Is any discharge observed from any part of the operation? ❑ ■ ❑ ❑ Discharge originated at Structure ❑ Application Field ❑ Other ❑ a. Was conveyance man-made? ❑ ■ ❑ ❑ b. Did discharge reach Waters of the State? (if yes, notify DWQ) ❑ ■ ❑ ❑ c. Estimated volume reaching surface waters? d. Does discharge bypass the waste management system? (if yes, notify DWQ) ❑ ■ ❑ ❑ 2. Is there evidence of a past discharge from any part of the operation? ❑ ■ ❑ ❑ 3. Were there any adverse impacts or potential adverse impacts to Waters of the State other than from a ❑ ■ ❑ ❑ discharge? Waste Collection, Storage & Treatment Yes No NA NE 4. Is storage capacity less than adequate? ❑ ■ ❑ ❑ If yes, is waste level into structural freeboard? ❑ 5. Are there any immediate threats to the integrity of any of the structures observed (I.e./ large trees, severe ❑ ■ ❑ ❑ erosion, seepage, etc.)? 6. Are there structures on -site that are not properly addressed and/or managed through a waste management ❑ ■ ❑ ❑ or closure plan? 7. Do any of the structures need maintenance or improvement? ■ ❑ ❑ ❑ 8. Do any of the structures lads adequate markers as required by the permit? (Not applicable to roofed pits, ❑ ■ ❑ ❑ dry stacks and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require maintenance or ❑ ■ ❑ ❑ improvement? Waste Application Yes No NA NE 10. Are there any required buffers, setbacks, or compliance alternatives that need maintenance or ❑ ■ ❑ ❑ improvement? 11. Is there evidence of incorrect application? ❑ ■ ❑ ❑ If yes, check the appropriate box below. Excessive Ponding? ❑ Hydraulic Overload? ❑ Frozen Ground? ❑ Heavy metals (Cu, Zn, etc)? ❑ Page: 4 Permit: AWS960051 Owner - Facility: Daw Farms Inc Inspection Date: 10/07/2009 Inspection Type: Compliance Inspection Facility Number: 960051 Reason for Visit: Routine Waste Application Yes No NA NE PAN? ❑ Is PAN > 10%/10 lbs.? ❑ Total P205? ❑ Failure to incorporate manure/sludge into bare soil? ❑ Outside of acceptable crop window? ❑ Evidence of wind drift? ❑ Application outside of application area? ❑ Crop Type 1 Com (Grain) Crop Type 2 Soybean, Wheat Crop Type 3 Crop Type 4 Crop Type 5 Crop Type 6 Soil Type 1 Craven Soil Type 2 Norfolk Soil Type 3 Soil Type 4 Soil Type 5 Soil Type 6 14. Do the receiving crops differ from those designated in the Certified Animal Waste Management ❑ ■ ❑ ❑ Plan(CAWMP)? 15. Does the receiving crop and/or land application site need improvement? ❑ ■ ❑ ❑ 16. Did the facility fail to secure and/or operate per the irrigation design or wettable acre determination? ❑ ■ ❑ ❑ 17. Does the facility lack adequate acreage for land application? ❑ ■ ❑ ❑ 18. Is there a lack of properly operating waste application equipment? ❑ ■ ❑ ❑ Records and Documents Yes No NA NE 19. Did the facility fail to have Certificate of Coverage and Permit readily available? ❑ ■ ❑ ❑ 20. Does the facility fail to have all components of the CAWMP readily available? ❑ ■ ❑ ❑ If yes, check the appropriate box below. WUP? ❑ Page:5 e Permit: AWS960051 Owner- Facility: Daw Farms Inc Inspection Date: 10/07/2009 Inspection Type: Compliance Inspection Facility Number: 960051 Reason for Visit: Routine Records and Documents Yes No NA NE Checklists? ❑ Design? ❑ Maps? ❑ Other? ❑ 21. Does record keeping need improvement? ❑ ■ ❑ ❑ If yes, check the appropriate box below. Waste Application? ❑ 120 Minute inspections? ❑ Weather code? ❑ Weekly Freeboard? ❑ Transfers? ❑ Rainfall? ❑ Inspections after > 1 inch rainfall & monthly? ❑ Waste Analysis? ❑ Annual soil analysis? ❑ Crop yields? ❑ Stocking? ❑ Annual Certification Form (NPDES only)? ❑ 22. Did the facility fail to install and maintain a rain gauge? ❑ ■ ❑ ❑ 23. If selected, did the facility fail to install and maintain a rainbreaker on irrigation equipment (NPDES only)? ❑ ❑ ■ ❑ 24. Did the facility fail to calibrate waste application equipment as required by the permit? ❑ ■ ❑ ❑ 25. Did the facility fail to conduct a sludge survey as required by the permit? ❑ ■ ❑ ❑ 26. Did the facility fail to have an actively certified operator in charge? ❑ ■ ❑ ❑ 27. Did the facility fail to secure a phosphorous loss assessment (PLAT) certification? ❑ ❑ ■ ❑ Otherissues Yes No NA NE 28. Were any additional problems noted which cause non-compliance of the Permit or CAWMP? ❑ ■ ❑ ❑ 29. Did the facility fail to properly dispose of dead animals within 24 hours and/or document and report those ❑ ■ ❑ ❑ mortality rates that exceed normal rates? 30. At the time of the inspection did the facility pose an air quality concern? If yes, contact a regional Air ❑ ❑ ❑ ■ Quality representative immediately. Page: 6 • Permit: AWS960051 Inspection Date: 10/07/2009 Otherlssues Owner - Facility: Daw Farms Inc Inspection Type: Compliance Inspection 31. Did the facility fail to notify regional DWO of emergency situations as required by Permit? 32. Did Reviewer/Inspector fail to discuss review/inspection with on -site representative? 33. Does facility require a follow-up visit by same agency? Facility Number: 960051 Reason for Visit: Routine Yes No NA NE Cl ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ Page: 7 0 Division of Water Quality ❑ Division of Soil and Water Conservation ❑ Other Agency Facility Number: 960051 Facility Status: Active Permit: AWS960051 ❑ Denied Access Inspection Type: Compliance Inspection Inactive or Closed Date: Reason for Visit: Routine County: Wayne Region: Washington Date of Visit: 06/11/2008 Entry Time:08:25 AM Exit Time: Incident #: Farm Name: Daw & Son Farm Owner Email: Owner: Delanor Daw Son Phone: 919-735-8332 Mailing Address: 653 Hare Rd Goldsboro NC 27534 Physical Address: Facility Status: ❑ Compliant ❑ Not Compliant Integrator: Goldsboro Hog Farms Inc Location of Farm: Latitude: 35028'25" Longitude: 77056'36" SR 1545, 2 miles north of SR 1523, west side of road. Question Areas: Discharges & Stream Impacts Waste Collection & Treatment Waste Application Records and Documents Other Issues Certified Operator: Paul Lewt Daw Operator Certification Number: 26042 Secondary OIC(s): On -Site Representative(s): Name Title Phone 24 hour contact name Brent Mitchell Phone: 919-738-3584 On -site representative Brent Mitchell Phone: 919-738-3584 Primary Inspector: Eric Newsome Phone: Inspector Signature: Date: Secondary Inspector(s): Page: 1 Permit: AWS960051 Owner - Facility: Delanor Daw Son Facility Number: 960051 Inspection Date: 06/11/2008 Inspection Type: Compliance Inspection Reason for Visit: Routine Inspection Summary: Saw CoC and Permit. WUP dated 1/2/2003. Land listed as Tract 4907 (F1, 2, 3, 4A, 413, 5, 6, 7). WARS (lbsN/1000gall): 4/7/08-1.5, 10/19/07-1.1, 5/24/07-1.8 Soil test results (117/08), Rept#17301: 0 tons/acre lime required (sample 5); Znl-540, Cut-326 (sample 5). 20081RR1/2 (corn): pull 2; (wheat): pull 4 20071RR1/2 (corn): pull 4; (SB): pull 3 PAN rates met and balanced. Typical pumping rate 210 gpm. Pumping volumes of irrigation events (6" drop vs 84,000 gallons and 7" drop vs 52,000 gallons) were consistent with changes in freeboard levels. Rainfall records were adequate. #7. Need to mow the vegetation that has grown on the northeast toe of the lagoon. 2007 sludge survey results (9/21/07): LTZ= 4.3', Thick= 3.1' 2007 calibration results (6/10/07): 55 psi @gun. 210gpm expected, 209gpm measured. Crop yields seen (126 bu of SB 1215/07; 486 bu of corn 10/11/07). Page: 2 Permit: AWS960051 Owner - Facility: Delanor Daw Son Facility Number: 960051 Inspection Date: 06/11/2008 Inspection Type: Compliance Inspection Reason for Visit: Routine Regulated Operations Design Capacity Current Population Swine Swine - Wean to Feeder 3,200 2,872 Total Design Capacity: 3,200 Total SSLW: 96,000 Waste Structures Type Identifier Closed Date Start Date Designed Freeboard Observed Freeboard agoon PRIMARY 06/01/92 19.00 31.00 Page: 3 Permit: AWS960051 Owner - Facility: Delanor Daw Son Facility Number : 960051 Inspection Date: 06/11/2008 Inspection Type: Compliance Inspection Reason for Visit: Routine Discharges & Stream Impacts Yes No NA NE 1. Is any discharge observed from any part of the operation? Discharge originated at: Structure Application Field Other a. Was conveyance man-made? b. Did discharge reach Waters of the State? (if yes, notify DWQ) c. Estimated volume reaching surface waters? d. Does discharge bypass the waste management system? (if yes, notify DWQ) 2. Is there evidence of a past discharge from any part of the operation? 3. Were there any adverse impacts or potential adverse impacts to Waters of the State other than from a discharge? Waste Collection, Storage & Treatment 4. Is storage capacity less than adequate? If yes, is waste level into structural freeboard? 5. Are there any immediate threats to the integrity of any of the structures observed (Led large trees, severe erosion, seepage, etc.)? n■DD 00011 0000 ❑■❑❑ Yes No NA NE 6. Are there structures on -site that are not properly addressed and/or managed through a waste management ❑ ■ ❑ ❑ or closure plan? 7. Do any of the structures need maintenance or improvement? 8. Do any of the structures lack adequate markers as required by the permit? (Not applicable to roofed pits, dry stacks and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require maintenance or improvement? Waste Application 10. Are there any required buffers, setbacks, or compliance alternatives that need maintenance or improvement? 11. Is there evidence of incorrect application? If yes, check the appropriate box below. Excessive Ponding? Hydraulic Overload? Frozen Ground? Heavy metals (Cu, Zn, etc)? ■❑❑❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ Yes No NA NE n■nn Dann n 11 Page: 4 Permit: AWS960051 Owner - Facility: Delanor Daw Son Inspection Date: 06/11/2008 Inspection Type: Compliance Inspection Facility Number : 960051 Reason for Visit: Routine Waste Application Yes No NA NE PAN? ❑ Is PAN > 10%/10 lbs.? ❑ Total P205? n Failure to incorporate manure/sludge into bare soil? ❑ Outside of acceptable crop window? ❑ Evidence of wind drift? ❑ Application outside of application area? ❑ Crop Type 1 Com, Wheat, Soybeans Crop Type 2 Crop Type 3 Crop Type 4 Crop Type 5 Crop Type 6 Soil Type 1 Craven sandy loam, 2 to 6% slopes, erode Soil Type 2 Norfolk loamy sand, 0 to 2% slopes Soil Type 3 Soil Type 4 Soil Type 5 Soil Type 6 14. Do the receiving crops differ from those designated in the Certified Animal Waste Management ❑ ■ ❑ ❑ Plan(CAWMP)? 15. Does the receiving crop and/or land application site need improvement? ❑ ■ ❑ ❑ 16. Did the facility fail to secure and/or operate per the irrigation design or wettable acre determination? ❑ ■ ❑ ❑ 17. Does the facility lack adequate acreage for land application? ❑ ■ ❑ ❑ 18. Is there a lack of properly operating waste application equipment? ❑ ■ ❑ ❑ Records and Documents Yes No NA NE 19. Did the facility fail to have Certificate of Coverage and Permit readily available? ❑ ■ ❑ ❑ 20. Does the facility fail to have all components of the CAWMP readily available? ❑ ■ 0 ❑ If yes, check the appropriate box below Page: 5 Permit: AWS960051 Owner - Facility: Delanor Daw Son Facility Number : 960051 Inspection Date: 06/11/2008 Inspection Type: Compliance Inspection Reason for Visit: Routine Records and Documents Yes No NA NE WUP? ❑ Checklists? Cl Design? ❑ Maps? ❑ Other? ❑ 21. Does record keeping need improvement? ❑ ■ ❑ ❑ If yes, check the appropriate box below. Waste Application? ❑ 120 Minute inspections? ❑ Weather code? ❑ Weekly Freeboard? ❑ Transfers? ❑ Rainfall? ❑ Inspections after> 1 inch rainfall & monthly? ❑ Waste Analysis? ❑ Annual soil analysis? ❑ Crop yields? ❑ Stocking? ❑ Annual Certification Form (NPDES only)? ❑ 22. Did the facility fail to install and maintain a rain gauge? ❑ ■ ❑ ❑ 23. If selected, did the facility fail to install and maintain a rainbreaker on irrigation equipment (NPDES only)? ❑ ❑ ■ ❑ 24. Did the facility fail to calibrate waste application equipment as required by the permit? ❑ ■ ❑ ❑ 25. Did the facility fail to conduct a sludge survey as required by the permit? ❑ ■ ❑ ❑ 26. Did the facility fail to have an actively certified operator in charge? ❑ ■ 0 0 27. Did the facility fail to secure a phosphorous loss assessment (PLAT) certification? ❑ ❑ m ❑ Other Issues Yes No NA NE 28. Were any additional problems noted which cause non-compliance of the Permit or CAWMP? ❑ ■ ❑ ❑ 29. Did the facility fail to properly dispose of dead animals within 24 hours and/or document and report those ❑ ■ ❑ ❑ mortality rates that exceed normal rates? Page: 6 Permit: AWS960051 Owner - Facility: Delanor Daw Son Facility Number: 960051 Inspection Date: 06/11/2008 Inspection Type: Compliance Inspection Reason for Visit: Routine Other Issues Yes No NA NE 30. At the time of the inspection did the facility pose an air quality concern? If yes, contact a regional Air Quality representative immediately. 31. Did the facility fail to notify regional DWQ of emergency situations as required by Permit? 32. Did Reviewer/Inspector fail to discuss review/inspection with on -site representative? 33. Does facility require a follow-up visit by same agency? Page: 7 E Division of Water Quality n Division of Soil and Water Conservation ❑ Other Agency Facility Number: 960051 Facility Status: Active Permit: AWS960051 ❑ Denied Access Inspection Type: Compliance Inspection Inactive or Closed Date: Reason for Visit: Routine County: Wayne Region: Washington Date of Visit: 06/30/2006 Entry Time:09:25 AM Exit Time: Incident #: Farm Name: Daw & Son Farm Owner: Delanor Daw Son Owner Email: Phone: 919-735-8332 Mailing Address: 653 Hare Rd Goldsboro NC 27534 Physical Address: Facility Status: ❑ Compliant ❑ Not Compliant Location of Farm: SR 1545, 2 miles north of SR 1523, west side of road. Integrator: Latitude:35°28'25" Longitude:77°56'36" Question Areas: Discharges & Stream Impacts Waste Collection & Treatment Waste Application Records and Documents Other Issues Certified Operator: Paul Lewt Daw Secondary OIC(s): Operator Certification Number: 26042 On -Site Representative(s): Name Title Phone On -site representative Paul Daw Phone: 919-738-1927 24 hour contact name George Pettus Phone: Primary Inspector: Joseph Gyamfi Inspector Signature: Secondary Inspector(s): Phone: Date: Page: 1 Permit: AWS960051 Owner - Facility: Delanor Daw Son Facility Number: 960051 Inspection Date: 06/30/2006 Inspection Type: Compliance Inspection Reason for Visit: Routine Inspection Summary: ` #19. Permit available in notebook, but missing CoC. Will mail copy to Paul Daw @ 330 Daw Pate Rd, Goldsboro, NC 27534 ` WUP dated 7/11/2002 Waste Analysis: 5/19/06 = 2.3 12/21 /05 = 2.1 9/21 /05 = 1.5 ` Soil test report dated 1/17/05, Lime applied on 3/18/06. Cu & Zn levels elevated, Need to be monitored, look at sampling techniques and tools. • Reviewed waste application records, complete and balanced. Weather codes and inspection initials completed. • Lagoon levels recorded twice a week. Changes in levels are consistent with pumping and precipitation events • Rainfall amounts recorded with initials ' Reviewed crop yield, stocking and mortality records ` Lagoon sludge survey report dated 4/16/05, sludge thickness = 1.8', LTZ = 5.5' - May apply for sludge survey exempt ` Irrigation calibration available, 4/5/05, 215GPM ' PLAT completed 2116/06, low ratings for all fields (7) Please mow the vegetation around lagoon to toe to allow effective inspection of lagoon dike for rodent activity, leakage or seepage. Farm & records well managed Page: 2 Permit: AWS960051 Owner - Facility: Delanor Daw Son Facility Number: 960051 Inspection Date: 06/30/2006 Inspection Type: Compliance Inspection Reason for Visit: Routine Regulated Operations Design Capacity Current Population Swine Q swine - Wean to Feeder 3,200 3,207 Total Design Capacity: 3,200 Total SSLW: 96,000 Waste Structures Type Identifier Closed Date Start Date Designed Freeboard Observed Freeboard agoon PRIMARY 06/01/92 19.00 32.00 Page: 3 Permit: AWS960051 Owner - Facility: Delanor Daw Son Facility Number: 960051 Inspection Date: 06/30/2006 Inspection Type: Compliance Inspection Reason for Visit: Routine Discharges & Stream Impacts Yes No NA NE 1. Is any discharge observed from any part of the operation? ❑ ■ n n Discharge originated at: Structure n Application Field n Other n a. Was conveyance man-made? n ■ n n b. Did discharge reach Waters of the State? (if yes, notify DWQ) n ■ c. Estimated volume reaching surface waters? d. Does discharge bypass the waste management system? (if yes, notify DWQ) n ■ n n 2. Is there evidence of a past discharge from any part of the operation? o ■ u In 3. Were there any adverse impacts or potential adverse impacts to Waters of the State other than from a n ■ n n discharge? Waste Collection Stora e & Treatment Yes No NA NE 4. Is storage capacity less than adequate? n ■ n n If yes, is waste level into structural freeboard? n 5. Are there any immediate threats to the integrity of any of the structures observed (I.e./ large trees, severe n ■ n n erosion, seepage, etc.)? 6. Are there structures on -site that are not properly addressed and/or managed through a waste management n ■ n n or closure plan? 7. Do any of the structures need maintenance or improvement? ■ n n n S. Do any of the structures lack adequate markers as required by the permit? (Not applicable to roofed pits, ❑ ■ n n dry stacks and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require maintenance or n ■ n n improvement? Waste Applicatiq9 Yes No NA NE 10. Are there any required buffers, setbacks, or compliance alternatives that need maintenance or n ■ n n improvement? 11. Is there evidence of incorrect application? n ■ 00 If yes, check the appropriate box below. Excessive Ponding? n Hydraulic Overload? n Frozen Ground? n Heavy metals (Cu, Zn, etc)? n Page: 4 Permit: AWS960051 Owner - Facility: Delanor Daw Son Inspection Date: 06/30/2006 Inspection Type: Compliance Inspection Facility Number: 960051 Reason for Visit: Routine Waste Application - - Yes No NA NE PAN? n Is PAN > 10%/10 lbs.? n Total P205? n Failure to incorporate manure/sludge into bare soil? n Outside of acceptable crop window? n Evidence of wind drift? n Application outside of application area? n Crop Type 1 Com, Wheat, Soybeans Crop Type 2 Crop Type 3 Crop Type 4 Crop Type 5 Crop Type 6 Soil Type 1 Craven Soil Type 2 Norfolk Soil Type 3 Soil Type 4 Soil Type 5 Soil Type 6 14. Do the receiving crops differ from those designated in the Certified Animal Waste Management n ■ n n Plan(CAWMP)? 15. Does the receiving crop and/or land application site need improvement? n ■ n n 16. Did the facility fail to secure and/or operate per the irrigation design or wettable acre determination? n ■ n n 17. Does the facility lack adequate acreage for land application? n ■ n n 18. Is there a lack of properly operating waste application equipment? n ■ n n Records and Documents Yes No NA NE 19. Did the facility fail to have Certificate of Coverage and Permit readily available? ■ n n n 20. Does the facility fail to have all components of the CAWMP readily available? n ■ n n If yes, check the appropriate box below. WUP? n Page: 5 Permit: AWS960051 Owner - Facility: Delanor Daw Son Facility Number: 960051 Inspection Date: 06/30/2006 Inspection Type: Compliance Inspection Reason for Visit: Routine Records and Documents Yes No NA NE Checklists? n Design? n Maps? Other? n 21. Does record keeping need improvement? n ■ n n If yes, check the appropriate box below. Waste Application? n 120 Minute inspections? n Weather code? n Weekly Freeboard? n Transfers? n Rainfall? n Inspections after > 1 inch rainfall & monthly? n Waste Analysis? n Annual soil analysis? n Crop yields? n Stocking? n Annual Certification Form (NPDES only)? n 22. Did the facility fail to install and maintain a rain gauge? n ■ n n 23. If selected, did the facility fail to install and maintain a rainbreaker on irrigation equipment (NPDES only)? n n ■ n 24. Did the facility fail to calibrate waste application equipment as required by the permit? In ■ n n 25. Did the facility fail to conduct a sludge survey as required by the permit? n ■ n n 26. Did the facility fail to have an actively certified operator in charge? n ■ n n 27. Did the facility fail to secure a phosphorous loss assessment (PLAT) certification? n n ■ n Otherlssues Yes No NA NE 28. Were any additional problems noted which cause non-compliance of the Permit or CAWMP? n ■ n n 29. Did the facility fail to properly dispose of dead animals within 24 hours and/or document and report those n ■ n n mortality rates that exceed normal rates? 30. At the time of the inspection did the facility pose an air quality concern? If yes, contact a regional Air n ■ n n Quality representative immediately. Page: 6 Permit: AWS960051 Owner - Facility: Delanor Daw Son Facility Number: 960051 Inspection Date: 06/30/2006 Inspection Type: Compliance Inspection Reason for Visit: Routine Otherlssues Yes No NA NE 31. Did the facility fail to notify regional DWQ of emergency situations as required by Permit? 32. Did Reviewer/Inspector fail to discuss review/inspection with on -site representative? 33. Does facility require a follow-up visit by same agency? n■nn n■on n■nn Page: 7 0 Division of Water Quality (� Division of Soil and Water Conservation ❑ Other Agency --------------- ___ _ Facility Number: 960051 Facility Status: Active Permit: AWS960051 ❑ Denied Access Inspection Type: Compliance Inspection Inactive or Closed Date: Reason for Visit: Routine County: Wayne Region: Washington Date of Visit: 04/04/2007 Entry Time:08:00 AM Exit Time: Farm Name: Daw & Son Farm Owner: Delanor Daw Son Incident #: Owner Email: Phone: 919-735-8332 Mailing Address: 653 Hare Rd Goldsboro NC 27534 Physical Address: Facility Status: ❑ Compliant ❑ Not Compliant Location of Farm: SR 1545, 2 miles north of SR 1523, west side of road. Question Areas: W Discharges & Stream Impacts jj Records and Documents Certified Operator: Paul Lewt Daw Secondary OIC(s): Integrator: Latitude:35°28'25" Longitude:77°56'36" d Waste Collection & Treatment ® Other issues On -Site Representative(s): Name On -site representative Paul Daw 24 hour contact name Paul Daw W Waste Application Operator Certification Number: 26042 Title Phone: Phone: Primary Inspector: Megan Hartwell Phone: Inspector Signature: Date: Secondary Inspector(s): Phone Page: 1 Permit: AWS960051 Owner - Facility: Delanor Daw Son Facility Number: 960051 Inspection Date: 0d/04/2007 Inspection Type: Compliance Inspection Reason for Visit: Routine Inspection Summary: COC and Permit 2009 Waste Analysis 1-19-07 1.6 11-21-06 1.8 8-9-06 1.5 Soil test 11-29-06 highest lime 0 tons Cu and Zn values within range Rainfall and freeboard complete and correspond with irrigation Irrigation records complete 'send copy of crop yield records and rainfall and freeboard records reporting form and new IRR-2 form Sludge survey complete 4-16-05 thick-1.8' LTZ-55} Complete next survey in 2007 Calibrations complete 4-5-05 with 215 GPM Page: 2 Permit: AlNS960051 Owner - Facility: Delanor Daw Son Facility Number: 960051 Inspection Date: 04/04/2007 Inspection Type: Compliance Inspection Reason for Visit: Routine Regulated Operations Design Capacity Current Population Swine Swine - Wean to Feeder 3,200 2,757 Total Design Capacity: 3,200 Total SSLW: 96,000 Waste Structures Type Identifier Closed Date Start Date Designed Freeboard Observed Freeboard agoon PRIMARY 06/01/92 19.00 32.00 Page: 3 Permit: AWS960051 Owner - Facility: Delanor Daw Son Facility Number: 960051 Inspection Date: 04/04/2007 Inspection Type: Compliance Inspection Reason for Visit: Routine Discharges & Stream Impacts Yes No NA NE 1. Is any discharge observed from any part of the operation? D ■ ❑ ❑ Discharge originated at: Structure n Application Field n Other n a. Was conveyance man-made? n ■ n n b. Did discharge reach Waters of the State? (if yes, notify DWQ) ❑ ■ ❑ ❑ c. Estimated volume reaching surface waters? d. Does discharge bypass the waste management system? (if yes, notify DWQ) n ■ n n 2. Is there evidence of a past discharge from any part of the operation? n ■ ❑ n 3. Were there any adverse impacts or potential adverse impacts to Waters of the State other than from a n ■ n n discharge? Waste Collection, Storage & Treatment Yes No NA NE 4. Is storage capacity less than adequate? n ■ n n If yes, is waste level into structural freeboard? n 5. Are there any immediate threats to the integrity of any of the structures observed (I.e./ large trees, severe ❑ ■ ❑ ❑ erosion, seepage, etc.)? 6. Are there Structures on -site that are not properly addressed and/or managed through a waste management ❑ !! ❑ ❑ or closure plan? 7. Do any of the structures need maintenance or improvement? n s n n S. Do any of the structures lack adequate markers as required by the permit? (Not applicable to roofed pits, D to n n dry stacks and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require maintenance or n ■ n n improvement? Waste Application Yes No NA NE 10. Are there any required buffers, setbacks, or compliance alternatives that need maintenance or D p ❑ n improvement? 11. Is there evidence of incorrect application? D ® n n If yes, check the apprcpriate box below. Excessive Ponding? ❑ Hydraulic Overload? ❑ Frozen Ground? D Heavy metals (Cu. Zn, etc)? rl Page: 4 Permit: AWS960051 Owner - Facility: Delanor Daw Son Inspection Date: 04/04/2007 Inspection Type: Compliance Inspection Facility Number: 960051 Reason for Visit: Routine Waste Application Yes No NA NE PAN? n Is PAN > 10%/10 ibs.? n Total P205? Failure to incorporate manure/sludge into bare soil? n Outside of acceptable crop window? n Evidence of wind drift? n Application outside of application area? rl Crop Type 1 Soybean, Wheat Crop Type 2 Cotton Crop Type 3 Crop Type 4 Crop Type 5 Crop Type 6 Soil Type 1 Norfolk Soil Type 2 Craven Soil Type 3 Soil Type 4 Soil Type 5 Soil Type 6 14. Do the receiving crops differ from those designated in the Certified Animal Waste Management n 0 n n Plan(CAWh,1P)? 15. Does the receiving crop and/or land application site need improvement? n ■ n n 16. Did the facility fail to secure and/or operate per the irrigation design or wettable acre determination? n ■ Q O 17. Does the facility lack adequate acreage for land application? n ■ 0 C1 18. Is :here a lack of properly operating waste application equipment? n ■ n n Records and Documents Yes No NA NE 19. Did the facility fail to have Certificate of Coverage and Permit readily available? n ©n n 20. Dori the facility fail to have all components of the CAWMP readily available? fl 13 ❑ fl If yes, check the appropriate box below. Wtip? n Page: 5 Permit: AAIS960051 Owner - Facility: Delanor Daw Son Facility Number: 960051 Inspection Date: 04/04/2007 Inspection Type: Compliance Inspection Reason for Visit: Routine Records and Documents Checklists? Design? Maps? Other? 21. Does record :seeping need improvement? Yes No NA NE n n n n n■nn If yes, check the appropriate box below. Waste Application? 120 Minute inspections? Weather code? n Weekly Freeboard? n Transfers? n Rainfall? ❑ Inspections after > 1 inch rainfall & monthly? n Waste Analysis? n Annual soil analysis? Crop yields? Stocking? n Annual Certification Form (NPDES only)? n 22. Did the facility fail to install and maintain a rain gauge? n ■ n n 23. If selected, did the facility fail to install and maintain a rainbreaker on irrigation equipment (NPDES only)? n ■ n n 24. Did the facility fail to calibrate waste application equipment as required by the permit? ❑ ■ n Cl 25. Did the facility fail to conduct a sludge survey as required by the permit? n ■ n n 26. Did :he facility fail to have an actively certified operator in charge? ❑ ■ n 27. Did the facility fail to secure a phosphorous loss assessment (PLAT) certification? D n ■ n Other ISSUCS Yes No NA NE 201. Were any additional problems noted which cause non-compliance of the Permit or CAWMP? ❑ ■ n n 29. Did the facility fail fo properly dispose of dead animals within 24 hours and/or document and report those n ■ n n mortality rates that exceed normal rates? 30. At the time of the inspection did the facility pose an air quality concern? If yes, contact a regional Air 00 n IN Quality rronresen'.ntive immediately. Page: 6 Permit: AWS960051 Owner - Facility: Delanor Daw Son Inspection Date: 04/04/2007 Inspection Type: Compliance Inspection Otherlssues 31. Did the facility fail to notify regional DWQ of emergency situations as required by Permit? 32. Did Revie .,er/Inspector fail to discuss review/inspection with on -site representative? 33. Does facility require a follow-up visit by same agency? Facility Number: 960051 Reason for Visit: Routine Yes No NA NE n■nn n■n❑ n■nn Page: 7 (Type of Visit O Compliance Inspection O Operation Review O Lagoon Evaluation Reason for Visit O Routine O Complaint O Follow up O Emergency Notification O Other ❑ Denied Access FacilityNumber 51 Date of Visit: 7/5/2000 Time: 8:04 AM Printed on: 7/72000 96 Not O erational Q Below Threshold 0 Permitted N Certified E3 Conditionally Certified E3 Registered Date Last Operated or Above Threshold: ......... _.......... , FarmName:!'ajr.tiaexx.''.P.igs........__...._._......_.........__........................................... County: WAVIC ............................................... !l'aRS�........ .Owner Name: CuKdelix... _.................... _. Sasser..... ........ _......................................... Phone No: 9]9-I34 D-9L9]9-I3frQ4.7.9............................. Facility Contact: Title: Phone No: MailingAddress: 36SQ.A!IG.11l.tl..._................_...._._.__.-........................._................. PACY.01C.Ac ......................................................... 2.7.8.6.3.............. Onsite Representative: Mr....&.TICS.. iAtSSCr. Geaxge Pettlxs.................................. Integrator: G.RldsbQr.Q.R.og.1.8r=....................................... Certified Operator:.or.deA1..F................................ 5.455rC......................................... _..... Operator Certification Number:1fi5 .. ....... Location of Farm: ......................::::::....................................:........................:::::::::::::::::::::::::::::::::::::::::::::::::::............................................... ® Swine ❑ Poultry ❑ Cattle ❑ Horse Latitude 35 28 25 u Longitude 77 56 36 Design Current Swine N Wean to Feeder 3200 3200 ❑ Feeder to Finish ❑ Farrow to Wean ❑ Farrow to Feeder ❑ Farrow to Finish ❑ Gilts ❑ Boars Number of Lagotins- ; C Design . Current' Design`Current" Poultry Capicity. Po ulation Cattle Cjj6acijy. Po ulatiOW ❑ Layer JE3 Dairy ❑ Non -Layer JE3 Non -Dairy ❑ Other Total Design Capacity 3,200 Total SSLW 96,000 = r ❑ Subsurface Drains Present JID Lagoon Area 10 Spray Field Area I notamg ronas i Solia Traps, I I .�LJ No Liquid Waste Management System 4M d _. �s xs r Discharges & Stream Impacts 1. Is any discharge observed from any part of the operation? ❑ Yes N No Discharge originated at: ❑ Lagoon ❑ Spray Field ❑ Other a. If discharge is observed. was the conveyance man-made? ❑ Yes N No b. If discharge is observed, did it reach Water of the State? (If ves, notify DWQ) ❑yes N No c. If discharge is observed- what is the estimated flow in gal/min? d. Does discharge bypass a lagoon system? (If ves, notify DWQ) ❑ Yes N No 2. Is there evidence of past discharge from any part of the operation? ❑ Yes N No 3. Were there any adverse impacts or potential adverse impacts to the Waters of the State other than from a discharge? ❑ Yes N No Waste Collection & Treatment 4. Is storage capacity (freeboard plus storm storage) less than adequate? ❑ Spillway ❑Yes N No Structure 1 Structure 2 Structure 3 Structure 4 Structure 5 Structure 6 Identifier: ......................................................._....-...............................................................................................................-..................... Freeboard (inches): 30 Continued on back Facility Number: 96-51 Date of Inspection 7/5/2000 0 Printed on: 7/7/2000 5. Are there any immediate threats to the integrity of any of the structures observed? (ie/ trees, severe erosion, ❑ Yes I@ No seepage, etc.) 6. Are there structures on -site which are not properly addressed and/or managed through a waste management or closure plan? ❑ Yes ® No (If any of questions 4-6 was answered yes, and the situation poses an immediate public health or environmental threat, notify DWQ) 7. Do any of the structures need maintenance/improvement? ❑ Yes ® No 8. Does any part of the waste management system other than waste structures require maintenance/improvement? ❑ Yes ® No 9. Do any stuctures lack adequate, gauged markers with required maximum and minimum liquid level elevation markings? ❑ Yes ® No Waste Application 10. Are there any buffers that need maintenance/improvement? ❑ Yes ® No 11. Is there evidence of over application? ❑ Excessive Ponding ❑ PAN ❑ Hydraulic Overload ❑ Yes ® No 12. Crop type Corn, Soybeans, Wheat 13. Do the receiving crops differ with those designated in the Certified Animal Waste Management Plan (CAWMP)? ❑ Yes ® No 14. a) Does the facility lack adequate acreage for land application? ❑ Yes ® No b) Does the facility need a wettable acre determination? ❑ Yes ® No c) This facility is pended for a wettable acre determination? ❑ Yes ® No 15. Does the receiving crop need improvement? 16. Is there a lack of adequate waste application equipment? Required Records & Documents 17. Fail to have Certificate of Coverage & General Permit readily available? 18. Does the facility fail to have all components of the Certified Animal Waste Management Plan readily available? (ie/ WUP, checklists, design, maps, etc.) 19. Does record keeping need improvement? (ie/ irrigation, freeboard, waste analysis & soil sample reports) 20. Is facility not in compliance with any applicable setback criteria in effect at the time of design? 21. Did the facility fail to have a actively certified operator in charge? 22. Fail to notify regional DWQ of emergency situations as required by General Permit? (ie/ discharge, freeboard problems, over application) 23. Did Reviewer/inspector fail to discuss review/inspection with on -site representative? 24. Does facility require a follow-up visit by same agency? 25. Were any additional problems noted which cause noncompliance of the Certified AWMP? 0 Nii-Viotatiotis:ordeftciencies-were-noted;during-this°visit::You_willreeeivenofurther . • . - correspondence about this.visit... .. ... ... ❑ Yes ® No ❑ Yes ® No ❑ Yes ® No ❑ Yes ® No ❑ Yes ® No ❑ Yes ® No ❑ Yes ® No ❑ Yes ® No ❑ Yes N No ❑ Yes ® No ❑ Yes N No :ecords available for review. lew waste utilization plan dated 7/3/00; meets the wetted acre requirement. Written on 67% of total cres. Naste samples are collected quarterly. foil analysis for 2000 - available. rrigation records are complete and balanced out. ,rounds are well managed. Fhe lagoon levels were maintained within permit i Well organized. uirements......... SEE PAGE 3 Reviewer/Inspector Name Ll Entered by Ann Tyndall 1 A Reviewer/inspector Signature: Date: Facility Number: 96-51 Date of Inspection 7/5/2000 Printed on: 7/7/2000 Odor Issues 26. Does the discharge pipe from the confinement building to the storage pond or lagoon fail to discharge at/or below ❑ Yes S No liquid level of lagoon or storage pond with no agitation? 27. Are there any dead animals not disposed of properly within 24 hours? ❑ Yes S No 28. is there any evidence of wind drift during land application? (i.e. residue on neighboring vegetation, asphalt, ❑ Yes S No roads, building structure, and/or public property) 29. Is the land application spray system intake not located near the liquid surface of the lagoon? ❑ Yes S No 30. Were any major maintenance problems with the ventilation fan(s) noted? (i.e. broken fan belts, missing or or broken fan blade(s), inoperable shutters, etc.) ❑ Yes S No 31. Do the animals feed storage bins fail to have appropriate cover? ❑ Yes S No 32. Do the flush tanks lack a submerged fill pipe or a permanent/temporary cover? ❑ Yes ❑ No ....throughout and after the 1999 hurricane season. Overall, the farm is well operated. If you have any questions, contact me at 252-946-6481, extension 318. GPS = L070512A Type of Visit (9) Compliance Inspection O Operation Review O Structure Eval. O Tech. Assistance O Conf. for Removal Reason for Visit *Routine O Complaint O Follow up O Referral O Emergency O Other ❑ Denied Access Facility Number 96 51 Date of Visit. 10-14-2004 Time: 758 0 Not Operational 0 Below Threshold ® Permitted ® Certified. 13 Conditionally Certified [3 Registered Date Last Operated or Above Threshold Farm Name: DawA.Son.k',arm........................ _........................... _._............................... County: !l.ay e....._........._....._.......___........ \'!ARQ...._.. Owner Name: Relanor. )AW.&Son............................. Phone No: (9191.I3S>333.'.............. _._.-..... .._................... __ Mailing Address: kS.3.Dare.iioad................................................................_................... Ciddsb rv..NG...._........__.................__.....2.7.53.4......... ... Facilin• Contact: Paul.Daw.........................................................Title: Phone No: 9].9:73fr_.4.424.................. __ Onsite Representative: Paul.AatY.............................................................................. Integrator:G.RldsbntQ.Doa�arms-._.................................. Certified Operator:Pall.1.Lewt ............................. DAW ................................................... Operator Certification Number:2.kQ4 ............................. Location of Farm: SR 1545, 2 miles north of SR 1523, west side of road. 0 Swine [I Poultry ❑ Cattle [I Horse Latitude 35 28 25 Longitude 77 56 36 Design Current Design Current Design Current Swine Capacity Population Poultry Capacity Population Cattle Capacity Population Fx Wean to Feeder 3200 ❑Layer ❑ Dairy ❑ Feeder to Finish ❑ Non -Layer ❑ Non -Dairy ❑ Farrow to Wean ❑ Farrow to Feeder ❑Other ❑ Farrow to Finish Total Design Capacity 3200 ❑ Gilts Total SSLW 96,000 ❑ Boars Number of Lagoons 1 Holding Ponds / Solid Trans Discharges & Stream Impacts 1. Is any discharge observed from any part of the operation? ❑ Yes 0 No Discharge originated at: ❑ Lagoon ❑ Spray Field []Other a. If discharge is observed, was the conveyance man-made? ❑ Yes ❑ No b. If discharge is observed, did it reach Water of the State? (If yes, notiA, DWQ) ❑ Yes ❑ No c. If discharge is observed, what is the estimated flow in gal/min? d. Does discharge bypass a lagoon system? (If yes, notify DWQ) ❑ Yes ❑ No 2. Is there evidence of past discharge from any part of the operation? ❑ Yes ® No 3. R-ere there any adverse impacts or potential adverse impacts to the Waters of the State other than from a discharge? ❑ Yes ® No Waste Collection & Treatment 4. Is storage capacity (freeboard plus storm storage) less than adequate? ❑ Spillway ❑ Yes 0 No Structure 1 Structure 2 Structure 3 Structure 4 Structure 5 Structure 6 Identifier: Freeb and (inches): 12,72/03 Continued Facility Number: 96-51 Date of Inspection 10 142004 5. Are there any immediate threats to the integrity of any of the structures observed? (ie/ trees, severe erosion, ❑ Yes ® No seepage, etc.) 6. Are there structures on -site which are not properly addressed and/or managed through a waste management or closure plan? ` [I Yes ®No (If any of questions 4-6 was answered yes, and the situation poses an immediate public health or environmental threat, notify DWQ) 7. Do any of the structures need maintenance/improvement? ❑ Yes ® No 8. Does any part of the waste management system other than waste structures require maintenance/improvement? ❑ Yes ®No 9. Do any stuctures lack adequate, gauged markers with required maximum and minimum liquid level elevation markings? ❑ Yes ®No Waste Application 10. Are there any buffers that need maintenance/improvement? ❑ Yes ® No 11. Is there evidence of over application? If yes, check the appropriate box below. ❑ Yes ®No ❑ Excessive Ponding ❑ PAN ❑ Hydraulic Overload ❑ Frozen Ground ❑ Copper and/or Zinc > 30( 12. Crop type Com, Soybeans, Wheat 13. Do the receiving crops differ with those designated in the Certified Animal Waste Management Plan (CAWNIP)? ❑ Yes ® No 14. a) Does the facility lack adequate acreage for land application? ❑ Yes ❑ No b) Does the facility need a wettable acre determination? ❑ Yes ❑ No c) This facility is pended for a wettable acre determination? ❑ Yes ❑ No 15. Does the receiving crop need improvement? ❑ Yes ®No 16. Is there a lack of adequate waste application equipment? ❑ Yes ® No Odor Issues 17. Does the discharge pipe from the confinement building to the storage pond or lagoon fail to discharge at/or below ❑ yes ❑ No liquid level of lagoon or storage pond with no agitation? 18. Are there any dead animals not disposed of properly within 24 hours? ❑ Yes ® No 19. Is there any evidence of wind drift during land application? (i.e. residue on neighboring vegetation, asphalt, ❑ Yes ® No roads, building structure, and/or public property) 20. At the time of the inspection did the facility pose an odor or air quality concern? If yes, contact a regional ElYes ® No Air Quality representative immediately. ` Comments (refer -to question #) Explain any YES,ansa ers and/or any recommendations or any other comments: Use drawings otfactlityo_better eiplam srtusttons (use additional pages as necessary): 0 Field Copy ❑Final Notes _ Records available for review Waste Analysis: 8-13-04 = 1.9 lbs 6-23-04 = 3.1 lbs 5-11-04 = 2.41bs 3-17-04 = 2.1 lbs 12-08-03 = 2.9lbs Soil analysis 6-11-03 & 6-24-02 Irrigation records are complete and balanced out. Freeboard levels are recorded weekly Continue to practice weed control. Need to shrub the down slopes of the dike wall If you have any questions contact your Technical Specialist or us @ 252-946-6481.. Re-,iewer/Inspector Name 'Lyn B. . rdison % Re-,iewer/Inspector Signature• �, . , �� �/ �_.� - �- .n. Date: 12n21n? U t, onrrnuea Facility Number: 96-51 Date of Inspection 10-14-2004 Required Records & Documents 21. Fail to have Certificate of Coverage & General Permit or other Permit readily available? ❑ Yes N No 22. Does the facility fail to have all components of the Certified Animal Waste Management Plan readily available? (ie/ WUP, checklists, design, maps, etc.) ❑ Yes N No 23. Does record keeping need improvement? If yes, check the appropriate box below. ❑ Yes N No ❑ Waste Application ❑ Freeboard ❑ Waste Analysis ❑ Soil Sampling 24. Is facility not in compliance with any applicable setback criteria in effect at the time of design? ❑ Yes N No 25. Did the facility fail to have a actively certified operator in charge? ❑ Yes N No 26. Fail to notify regional DWQ of emergency situations as required by General Permit? (ie/ discharge, freeboard problems, over application) ❑ Yes N No 27. Did Reviewer/Inspector fail to discuss review/inspection with on -site representative? ❑ Yes N No 28. Does facility require a follow-up visit by same agency? ❑ Yes N No 29. Were any additional problems noted which cause noncompliance of the Certified AWMP? ❑ Yes N No NPDES Permitted Facilities 30. Is the facility covered under a NPDES Permit? (If no, skip questions 31-35) ❑ Yes N No 31. If selected, did the facility fail to install and maintain rainbreakers on irrigation equipment? ❑ Yes ❑ No 32. Did the facility fail to install and maintain a rain gauge? ❑ Yes ❑ No 33. Did the facility fail to conduct an annual sludge survey? ❑ Yes ❑ No 34. Did the facility fail to calibrate waste application equipment? ❑ Yes ❑ No 35. Does record keeping for NPDES required forms need improvement? If }'es, check the appropriate box below. ❑ Yes ❑ No ❑ Stocking Form ❑ Crop Yield Form ❑ Rainfall ❑ Inspection After 1" Rain ❑ 120 Minute Inspections ❑ Annual Certification Form 113 No violations or deficiencies were noted during this visit. You will receive no further correspondence about this visit. (Additional Comments and/or Drawings' Questions 31-31 -NA 12112103 (Type of Visit 0° Compliance Inspection O Operation Review 0 Lagoon Evaluation I Reason for Visit 0° Routine O Complaint O Follow up O Emergency Notification O Other ❑ Denied Access Facility Number 96 51 Date of Visit: 12-10-2003 Time: 1045 FO Not Operational O Below Threshold ® Permitted ® Certified E3 Conditionally Certified E3 Registered Date Last Operated or Above Threshold:._ ...................... FarmName: DA v..&.So10X0rM........................................................................................ County: W.Ayixc ............................................... 1'l'ARO........ Owner Name: ................................................... RdamRi.AawA.SOA............................. Phone No: (91S�.IDS-� 32........................................................ Mailing Address: 651Hart:.22.oad.....................................................................:............... 'CJ..Rldsk9x.R.AC...................................................... Z.7.53.4 .............. Facility Contact: Title: Phone No: Onsite Representative: F,&W.1?a....................................................................................... Integrator: G.Q1dsbox.o.HRg.k:AICdGIS....................................... Certified Operator:)Qa17d.UWA ............................. I2aY.t'.................................................... Operator Certification Number: Z69..42............................. Location of Farm: R 1545, 2 miles north of SR 1523, west side of road. O Swine []Poultry []Cattle []Horse Latitude 35 ° 28 25 Longitude 77 • 56 36 °° Design Current Swine. Canacitv Ponulation ® Wean to Feeder 3200 3200 ❑ Feeder to Finish ❑ Farrow to Wean - ❑ Farrow to Feeder ❑ Farrow to Finish ❑ Gilts ❑ Boars Design Current Design Current Poultry Capacity Population Cattle Capacity Population ❑ Layer ❑ Dairy ❑ Non -Layer 1 ❑ Non -Dairy ❑ Other Total Design Capacity 3,200 Total SSLW 96,000 I Number of Lagoons 1� ❑ Subsurface Drains Present JE1 Lagoon Area ❑ Spray Field Area I Holding Ponds / Solid Traps ❑ Liquid No Waste Management System Discharges & Stream Impacts 1. Is any discharge observed from any part of the operation? Discharge originated at: ❑ Lagoon ❑ Spray Field ❑ Other a. If discharge is observed, was the conveyance man-made? b. If discharge is observed, did it reach Water of the State? (If yes, notify DWQ) c. If discharge is observed, what is the estimated flow in gal/min? d. Does discharge bypass a lagoon system? (If yes, notify DWQ) 2. Is there evidence of past discharge from any part of the operation? ❑ Yes ® No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ® No 3. Were there any adverse impacts or potential adverse impacts to the Waters of the State other than from a discharge? ❑ Yes ® No Waste Collection & Treatment 4. Is storage capacity (freeboard plus storm storage) less than adequate? ❑ Spillway ❑ Yes ® No Structure 1 Structure 2 Structure 3 Structure 4 Structure 5 Structure 6 Identifier: ...................................................................... Freeboard (inches): 35" VJ/VJ/Vl Facility Number: 96-51 Date of Inspection 12-10.2003 5. Are there any immediate threats to the integrity of any of the structures observed? (ie/ trees, severe erosion, seepage, etc.) 6. Are there structures on -site which are not properly addressed and/or managed through a waste management or closure plan? (If any of questions 4-6 was answered yes, and the situation poses an immediate public health or environmental threat, notify DWQ) 7. Do any of the structures need maintenance/improvement? 8. Does any part of the waste management system other than waste structures require maintenance/improvement? 9. Do any stuctures lack adequate, gauged markers with required maximum and minimum liquid level elevation markings? Waste Application 10. Are there any buffers that need maintenance/improvement? 11. Is there evidence of over application? ❑ Excessive Ponding ❑ PAN ❑ Hydraulic Overload [ 12. Crop type Corn, Soybeans, Wheat ❑ Yes ® No ❑ Yes ® No ❑ Yes ® No ❑ Yes ® No ❑ Yes ® No ❑ Yes ® No ❑ Yes ® No 13. Do the receiving crops differ with those designated in the Certified Animal Waste Management Plan (CAWMP)? ❑ Yes IN No 14. a) Does the facility lack adequate acreage for land application? ❑ Yes ❑ No b) Does the facility need a wettable acre determination? ❑ Yes ❑ No c) This facility is pended for a wettable acre determination? ❑ Yes ❑ No 15. Does the receiving crop need improvement? 16. Is there a lack of adequate waste application equipment? Required Records & Documents 17. Fail to have Certificate of Coverage & General Permit or other Permit readily available? 18. Does the facility fail to have all components of the Certified Animal Waste Management Plan readily available? (ie/ WUP, checklists, design, maps, etc.) 19. Does record keeping need improvement? (ie/ irrigation, freeboard, waste analysis & soil sample reports) 20. Is facility not in compliance with any applicable setback criteria in effect at the time of design? 21. Did the facility fail to have a actively certified operator in charge? 22. Fail to notify regional DWQ of emergency situations as required by General Permit? (ie/ discharge, freeboard problems, over application) 23. Did Reviewer/Inspector fail to discuss review/inspection with on -site representative? 24. Does facility require a follow-up visit by same agency? 25. Were any additional problems noted which cause noncompliance of the Certified AWMP? ❑ Yes ® No ❑ Yes ® No ❑ Yes ® No ❑ Yes ® No ❑ Yes ® No ❑ Yes ® No ❑ Yes ® No ❑ Yes ® No ❑ Yes ® No ❑ Yes ® No ❑ Yes ® No E3 No violations or deficiencies were noted during this visit. You will receive no further correspondence about this visit. pla 'Commeritsr(refer to uestion�#) Eainsany YES answerssand/or any recommendations or an {other=comments+,„ "�,.y '�.`,s `.4rq'°�'rxr.X ���`� re.3 P.. a,E y•, :,. _ %'�' xrk .,..� '-s"xr4x _....�.._k�atr,Z.t,�.�:.Sa'+v&4=.b`...-'�.aic. a '��'ya ' ,-i Ei3se+drawings�ofafaclity�4oibetter�eaplamrsituaiions'(use addihonalopages as necessary) i,.� 4, 3 � � r -� ❑Field COPY ®Final Notes t a ��r�.�- �s . � � �x ,. -� � � I �^ r *� a'; � � Y ,,� �. �:.�',•,'i �. rt� �.2 ��'e. t�;�.:� .4. 4... �: ...> � �w S I�•�:a 4I' �.7 �4..?e r a'I•..:.. q;" :t-v+avr.-.Y.zk.-S`P-:.:;'�:".t�r"r*i .' .k.� Records were available ast analysis 12-8-03 2.9 lbs 10-10-03 2.4 lbs 8-8-03 1.7 lbs 5-23-03 2.4lbs 3-6-03 3.0lbs 1-6-03 2.2 lbs 10-24-03 1.6 lbs Reviewer/Inspector Name Lyn r Bison _B:RH Reviewer/Inspector Signature: Date: c 1 U- D 3 v O5103101 Continued Facility Number: 96-51 Date of Inspection 12-10-2003 Odor Issues 26. Does the discharge pipe from the confinement building to the storage pond or lagoon fail to discharge at/or below ❑ Yes ❑ No liquid level of lagoon or storage pond with no agitation? 27. Are there any dead animals not disposed of properly within 24 hours? ❑ Yes ® No 28. Is there any evidence of wind drift during land application? (i.e. residue on neighboring vegetation, asphalt, ❑ Yes ® No roads, building structure, and/or public property) 29. Is the land application spray system intake not located near the liquid surface of the lagoon? ❑ Yes ® No 30. Were any major maintenance problems with the ventilation fan(s) noted? (i.e. broken fan belts, missing or or broken fan blade(s), inoperable shutters, etc.) ❑ Yes ® No 31. Do the animals feed storage bins fail to have appropriate cover? ❑ Yes ® No 32. Do the flush tanks lack a submerged fill pipe or a permanent/temporary cover? ❑ Yes ❑ No u ?.- :-zs.,'C, a �i�ddltKgnA1 rie_nts1an_ .6WD_ravnngs 7;'„ w' r. .'r d -r .l _ z - rr. a . Soil analysis - up thru 2003 available Irrigation records are complete and balanced out. Freeboard levels are recorded weekly. Continue to manage the vegetation along the dike wall especially along the downslope of dike wall. Farm is well managed. If you have any questions, contact your Technical Specialist or me at 252-946-6481. Facility Number Date of Visit: 3/27/2002 Time: 1448 p Not Operational p ffmow res o N Permitted N Certified p Conditionally Certified p Registered Date Last Operated or Above Threshold: ......................... Farm Name: Daw & Son Farm County:.W..ayne................................................ .WaRG........ Owner Name: Delanor Daw & Son Phone No: (919) 735-8332 Mailing Address: 653.Haxe.Road..................................................................................... Goldsbara..NC.............. ........................................ 27534 .............. FacilityContact: ...............................................................................Title:............................................................... Phone No:.................................................... Onsite Representative: D,elanar,Paul:&.txeorgaP.ettus........................................ Integrator: Goldsboro.Hog.Farms....................................... Certified Operator:P.aul.Lewt ............................ Da-ty...................... ............................... Operator Certification Number: 26042............................. Location of Farm: 0 Swine 0 Poultry 0 Cattle 0 Horse Latitude ©• ®' ©" Longitude ©• �' ®" Swine Design, Current Design „ .,Current, Design Current Capacity Population PoultryCapacity* Population " Cattle Capacity. Population ®Wean to Feeder 0 Feeder to mis 0 Farrow to Wean 0 Farrow to Feeder 0 Farrow to Finish 10 Gilts 0 Boars 0 ayer JE3 Dany 0 Non -Layer 10 Non-Ijairy 0 Other Total Design Capacity 31200 'Total SSLW 969000 I Number' of Lagoons �� ,jOSubsurfaceerrains�cesent 0 Lagoon Area JE3 Spray Field Area I Holding Ponds / Soli diTraps 0 0 Liquid Waste Management System Discharges & Stream Impacts 1. Is any discharge observed from any part of the operation? 0 Yes ® No Discharge originated at: 0 Lagoon 0 Spray Field 0 Other a. If discharge is observed, was the conveyance man-made? 0 Yes 0 No b. If discharge is observed, did it reach Water of the State? (If yes, notify DWQ) 0 Yes 0 No c. If discharge is observed, what is the estimated flow in gaVmin? d. Does discharge bypass a lagoon system? (If yes, notify DWQ) 0 Yes 0 No 2. Is there evidence of past discharge from any part of the operation? 0 Yes ®No 3. Were there any adverse impacts or potential adverse impacts to the Waters of the State other than from a discharge? 0 Yes ®No Waste Collection & Treatment 4. Is storage capacity (freeboard plus storm storage) less than adequate? 0 Spillway 0 Yes ®No Structure I Structure 2 Structure 3 Structure 4 Structure 5 Structure 6 Identifier: ................................................................................................................................................................................................................... Freeboard(inches): ...............36................................................................................................................................................................................................... I Facility Number: 96-51 Date of Inspection 5. Are there any immediate threats to the integrity, of any of the structures observed? (ie/ trees, severe erosion, ❑ Yes ® No seepage, etc.) 6. Are there structures on -site which are not properly addressed and/or managed through a waste management or closure plan? (If any of questions 4-6 was answered yes, and the situation poses an ❑ Yes N No immediate public health or environmental threat, notify DWQ) 7. Do any of the structures need maintenance/improvement? ❑ Yes ®No 8. Does any part of the waste management system other than waste structures require maintenance/improvement? ❑ Yes ® No 9. Do any stuctures lack adequate, gauged markers with required maximum and minimum liquid level elevation markings? ❑ Yes ®No Waste Application 10. Are there any buffers that need maintenance/improvement? ❑ Yes ® No 11. Is there evidence of over application? ❑ Excessive Ponding ❑ PAN p Hydraulic Overload ❑ Yes ®No 12. Crop type Corn, Soybeans, Wheat 13. Do the receiving crops differ with those designated in the Certified Animal Waste Management Plan (CAWMP)? ❑ Yes ® No 14. a) Does the facility lack adequate acreage for land application? ❑ Yes ®No b) Does the facility need a wettable acre determination? ❑ Yes ®No c) This facility is pended for a wettable acre determination? ❑ Yes ® No 15. Does the receiving crop need improvement? ❑ Yes ® No 16. Is there a lack of adequate waste application equipment? ❑ Yes ®No Reauired Records & Documents 17. Fail to have Certificate of Coverage & General Permit or other Permit readily available? ❑ Yes IN No 18. Does the facility fail to have all components of the Certified Animal Waste Management Plan readily available? (ie/ WUP, checklists, design, maps, etc.) ❑ Yes ®No 19. Does record keeping need improvement? (ie/ irrigation, freeboard, waste analysis & soil sample reports) ❑ Yes ® No 20. Is facility not in compliance with any applicable setback criteria in effect at the time of design? ❑ Yes ®No 21. Did the facility fail to have a actively certified operator in charge? ❑ Yes ®No 22. Fail to notify regional DWQ of emergency situations as required by General Permit? tie/ discharge, freeboard problems, over application) ❑ Yes ® No 23. Did Reviewer/Inspector fail to discuss review/inspection with on -site representative? ❑ Yes ®No 24. Does facility require a follow-up visit by same agency? ❑ Yes ®No 25. Were anv additional problems noted which cause noncompliance of the Certified AWMP? ❑ Yes ® No p No violations or deficiencies were noted during this visit. You will receive no further correspondence about this visit. Comments (refer to question #0 : Egplain any YES answers and/or any recommendations or any other comments Use drawings of facility to better, eii lam situations (use additional pages as necessary) Field Copy p Fuial Notes taste analysis - 3/15/02 = 2.9 lbs.; 1/8/02 = 2.2 lbs.; 10/23/01 = 2.1 lbs.; 8/10/01 = 1.5 lbs.; 6/11/01 = 1.4 lbs. oil analysis - up through 2001 available - time put out 11/2001 Tigation records are complete and balanced out. reeboard levels are recorded weekly as required...... on calendar .ecords are complete and balanced out. .eminder: Suggest to pull waste sample every 2 months; soil samples are required annually. (SEE PAGE 3) Reviewer/Inspector Name Lyn;B. Hardison . entered byAnn Tyndall Reviewer/Inspector Signature: y Y �,,� Date: 4- 2-2 -e' Z. 05103101 Continued aci sty um er: 96_51 Date of Inspection Odor Issues 26. Does the discharge pipe from the confinement building to the storage pond or lagoon fail to discharge at/or below ❑ Yes ❑ No liquid level of lagoon or storage pond with no agitation? 27. Are there any dead animals not disposed of properly within 24 hours? ❑ Yes ® No 28. Is there any evidence of wind drift during land application? (i.e. residue on neighboring vegetation, asphalt, ❑ Yes ® No roads, building structure, and/or public property) 29. Is the land application spray system intake not located near the liquid surface of the lagoon? ❑ Yes ® No 30. Were any major maintenance problems with the ventilation fan(s) noted? (i.e. broken fan belts, missing or or broken fan blade(s), inoperable shutters, etc.) ❑ Yes ® No 31. Do the animals feed storage bins fail to have appropriate cover? ❑ Yes ® No 32. Do the flush tanks lack a submerged fill pipe or a permanent/temporary cover? []Yes ❑ No ,tatton on aixe wan is wen estaottsnea. yfields are in good shape. Jnue to practice weed control. farm is well managed. iu have any questions, contact your Technical Specialist or us at 252-946-6481. f . t p DWQ Animal Feedlot Operation Site Inspection 1* Kounne 0 a,ompinmi 0 runuw-up ui "W%Z u.apoauou Facility Number Farm Status: 13 Registered p Applied for Permit .. N Certified p Permitted in Not OperationaM Date Last Operated: Farm Name: Partners'N' Pigs Date of Inspection Time of Inspection ® 24 hr. (hh:mm) County:...W..ayne................................................ .W..aRO........ OwnerName: CorddlE.............................. Sasser ......................................................... Phone No: 73.4.1934.................................................................... Facility Contact: Cordell.Sasser................................................Title: O.Witer ................................................ Phone No: .73.4.1934................................ Mailing Address: 3659...LV.C.111N.................................................................................... rilmVillt-Dic ......................................................... 27861 .............. Onsite Representative: Cordell.Sasser........................................................................... Integrator: Goldsbnra.Hog.Farms....................................... Certified Operator: CorAcILE ............................. Sasser ............................................... Operator Certification Number:16582 ............................. Location of Farm: Latitude ©• ®' ©" Longitude ©• ®®" pe of Operation .Design Current Swine ' Capacity -Population Wean to Feeder Feeder to Finish Farrow to Wean Farrow to Feeder Farrow to Finish p Other _,-,Number of Lagoons /'Holding Ponds - Design Current Design Current Poultry Capacity Population :Cattle Capacity Population p Layer I 1[3 Dairy p Non -Layer 1 10 on- any Total Design Capacity 3,200 Total SSLW 96, General 1. Are there any buffers that need maintenance/improvement? p Yes ® No 2. Is any discharge observed from any part of the operation? 13 Yes ® No Discharge originated at: p Lagoon p Spray Field p Other a. If discharge is observed, was the conveyance man-made? O Yes p No b. If discharge is observed, did it reach Surface Water? (If yes, notify DWQ) p Yes p No c. If discharge is observed, what is the estimated flow in gal/min? d. Does discharge bypass a lagoon system? (If yes, notify DWQ) 13 Yes p No 3. Is there evidence of past discharge from any part of the operation? p Yes ® No 4. Were there any adverse impacts to the waters of the State other than from a discharge? p Yes ®No 5. Does any part of the waste management system (other than lagoons/holding ponds) require 13 Yes ® No maintenance/improvement? 4/30/97 Itacility Number: _51 6. Is facility not in compliance with any applicable setback criteria in effect at the time of design? p Yes ® No 7. Did the facility fail to have a certified operator in responsible charge? p Yes ®No 8. Are there lagoons or storage ponds on site which need to be properly closed? p Yes N No Structures (Lagoons and/or Holdin¢ Ponds) 9. Is storage capacity (freeboard plus storm storage) less than adequate? p Yes ®No Freeboard (ft): Structure 1 Structure 2 Structure 3 Structure 4 Structure 5 Structure 6 _.__.... 2 24........ ...... .................. .......... _....... ...................................... .............. ........................ .......... _.......................... ............................... 10. Is seepage observed from any of the structures? p Yes N No 11. Is erosion, or any other threats to the integrity of any of the structures observed? p Yes ® No 12. Do any of the structures need maintenance/improvement? p Yes ® No (If any of questions 9-12 was answered yes, and the situation poses an immediate public health or environmental threat, notify DWQ) 13. Do any of the structures lack adequate minimum or maximum liquid level markers? p Yes ® No Waste Application 14. Is there physical evidence of over application? p Yes ® No (If in excess of WMP, or runoff entering waters of the State, notify DWQ) 15. Crop type .......1 ~am.(Silage.&.Brain)....... ISmalL.(irain�.(Wh��eat,.Barley,..................................................................................................................... Do differ with those designated m the animal Waste Management Plan (AWMP)? p Yes N No 16. the receiving crops 17. Does the facility have a lack of adequate acreage for land application? p Yes ®No 18. Does the receiving crop need improvement? p Yes ®No 19. Is there a lack of available waste application equipment? p Yes ® No 20. Does facility require a follow-up visit by same agency? p Yes ®No 21. Did Reviewer/Inspector fail to discuss review/inspection with on -site representative? p Yes ®No For Certified Facilities Only 22. Does the facility fail to have a copy of the Animal Waste Management Plan readily available? p Yes ®No 23. Were any additional problems noted which cause noncompliance of the Certified AWMP? p Yes ®No 24. Does record keeping need improvement? ® Yes p No Reviewer/Inspector Name Reviewer/Inspector Signature: >&pvNI "�a-p1..n�00 Date: Site Requires Immediate Attention: Facility No. 116—S-r Ses-26 DIVISION OF ENVIRONMENTAL MANAGEMENT ANIMAL FEEDLOT OPERA ION TE VISITATION RECORD Date: , , 1995 Time: Farm Name/Owner: 71p�T NLpp,S �� t"l .4 s JQSSSej�, Mailing Address: lIC 1 111 !Je G j $C County: fV Integrator: Phone: On Site Representative:p:� Z ( A Fjm,//�(Phone: 3 Physipal Address/Location: Cf,:,I fc�_ 1 w.: p< 1iia-41, .-P<so i kro ._ Type of Operation: Swine _ X Poultry Cattle Design Capacity: MW Wt.4utsenx No. of Animals on Site: C�) DEM Certification No.: ACE ' DEM Certification No.: ACNEW Latitude: - fig 2�Longitude: -)Z ��Elevation: Ft Circle Yes or No Does the Animal Waste Lagoon have sufficient freeboard of 1 Ft + 25 year 24 hour storm event? (approximately 1 Ft + 7 in) es or No Actual Freeboard: Ft n Inches Was any seepage observed from the lagoon(s)? Yes o No Was any erosion observed? Yes or(� Is adequate land available for spray? es or No h „ j Is the cover crop adequate? or No /b•�4 Ac003, �RAj /Uec�. Crop(s) being utilized: a Oz>R AJ A UAit Does the facility meet SCS minimum setback criteria? � G� 200 Ft from Dwellings? �s or No 100 Ft from Wells? Cea�r No i Is the animal waste stockpiled within 100 Ft of USGS Blue Line Stream? Yes or® Is animal wasted applied or spray irrigated within 25 Ft of a USGS Map Blue Line? Yes or o Is animal waste discharged into waters of the state b man-made ditch, flushing system, or other similar man-made devices? Yes or o If Yes, please explain: Does the facility maintain adequate waste mana ement records (volumes o manure, land applied, spray irrigated on specific a r ge with ver crop)? Ye or No LV P1'ty qlc=L4 Inspector (dame ignature Jr CC: Facility Assessment Unit Comments & Sketch on Back of Sheet DEM SITE VISITATION RECORD Page Two Sketch: i