Loading...
HomeMy WebLinkAboutWQ0040742_Application_20190328( -"'I .2"EST Civil - Surveying- Geotechnical PO Box 268 Concord, NC 28026 (45 Spring Street SW) Phone: 704.786.5404 Fax: 704.786.7454 Web: www.cesilds.com License No. C-0263 transmittal To: NCDEQ From: Mooresville Regional Office Project Name: Address: 610 East Center Avenue Project No.: Suite 301 Mooresville, NC 28115 Date: Phone: Re: Fax: Cc: ® For Review and Comment c.lV[-D/NCD F_ N R/DViR R Uvapos CESI MJC'RFSVILLF RI, G!0NAL. OFFICE David Reese, PE The Lodge at Hickory 180457.000 3/27/2019 For Approval As Requested For vour fiiP Copies Description 1 Fee Check 1 NCDEQ Cover Letter 2 Fast Track Sewer Systems Extension Application (FTA 04-16) 2 Flow Tracking for Sewer Extension Application (FTSE 10-18) 2 Specifications 2 24" x 36" Plans 2 USGS Topo and Aerial March 27, 2019 NCDEQ 610 East Center Avenue Suite 301 Mooresville, NC 28117 Re: Sewer Extension — The Lodge at Hickory Enclosed, please find our Sewer Extension submittal for proposed new sewer extension permit. for the above referenced needed, please don't hesitate to contact us. Inpsurnrt If have an project. Please review this for you review. The sewer extension will serve a two b f the a y questions or additional items The extension will consist of approximatelyPplication, the followin lledr°°1n multifamil g items are enclosed 362 feet of 8"PVC designed or 240 consisting of 8o units. Two (2) paper copies of the following: gal/day flow. 1 • Fast Track Sewer Systems Extension 2, Flow Tracking for Sewer Extension A Application(FTA 04-16) ISpecifications pplicati ication 4. Sealed and signed plan drawings (FTSE 10-18) 5. USGS Topo and Aerial g with cover sheet One (1) fee check. Page 1 of 1 Division Of Water Resources WR State of North Carolina Department of Environmental Quality Division 15A NCAC 02T .0300 — FAST TRACK SEWER SYST MEXTEN I N APPLICATION Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: ()C>'1L�(� �`- to be completed by DWR) All items must be com leted or the a lication will be returned 1. APPLICANT INFORMATION: 1 2 3. 4. 5. Applicant's name: City of Hickory (company, municipality, HOA, utility, etc.) Applicant type: El Individual ❑ Corporation ❑ General Partnership ❑ Federal ❑ State/Count Signature authority's name: Warren Wood y ®Municipal per l5A NCAC 02T .0106(b Title: City—er Applicant's mailing address: POD City: Hicckor•y State: NC Zip: 28603-0398 Applicant's contact information: Phone number: (828) 323-7412 If. PROJECT INFORMATION: Email Address: wwoodnhickorync ov RECE!VED/NCDENR/DWR MAR v 3 2019 WQI,OS MOORFSVILLE RFG'IONAL OFFICE ❑ Privately -Owned Public Utility ❑ Other I . Project name: The Lodge at Hickory 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: W 00 If new construction but art of a master plan, � and issued date: p p , provide the existing 3. County where project is located: Catawba Permit number: WQ00 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.7_ 173100 Longitude: --8.3_ 485880 5. Parcel ID (if applicable): 370214246271 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: David F. Reese License Number: 0108163 Firm: CESI Mailing address: PO Box 268 City: Concord State: NC Zip: 28026-0268 Phone number: (704) 786-5404 Email Address: davidreese@cest� 'ca�s com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: I. Facility Name: Henry Fork W WTP Permit Number: NCO040797 Owner Name: City o_ ferry V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): l . Permit Number(s): WQ Downstream (Receiving) Sewer Size: 12 inch System Wide Collection System Permit Numbers if applicable): WQCS00020 Owner Name(s): City of Hickory FORM: FTA 04-16 Page 1 of 5 VI. GENERAL REQUIREMENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes [:]No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Property Owners' Association has an Operational Agreement (FORM HOA) been attached? ❑ Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ® Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Businesses /offices /factories El Swimming Pool/Filter Backwash ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: l 00 % Domestic/Commercial % Commercial % Industrial (See 15A NCAC 02T 0103(20)) ,Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T 0114(f)? ❑ Yes ® No ➢ If Yes, provide a copy of flow reduction approval letter Summarize wastewater generated by project: Establishment Type (see 02T.01140 Daily Design Flow a01h, =0.EUni:tsE=Flow Dwelling Unit (2 Bedroom Multifamily Facility 240 gal/day 80 19,200 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 19,200 GPD a See 15A NCAC 02T 0114(b) (d) (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 19,200 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 +/- 361.57 PVC ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT l . Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - ° 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): FSize (inches) Length (feet) Material Power reliability in accordance with 15A NCAC 02T 0305(h ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B); ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T.0305(f)): l . Does the project comply with all separations found in 15A NCAC 02T 0305(f) & ( ) ➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer s stems: ® Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) Water mains (vertical -water over sewer including in benched trenches) 24 inches Water mains (horizontal) 18 inches Reclaimed water lines (vertical - reclaimed over sewer) 10 feet Reclaimed water lines (horizontal - reclaimed over sewer) 18 inches **Any private or public water supply source, including any wells, WS-I waters of Class I or 2 feet Class II impounded reservoirs used as a source of drinking water **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal 100 feet high water (or tide elevation) and wetlands (see item IX.2) **Any other stream, lake, impoundment, or ground water lowering and surface drainage 50 feet ditches Any building foundation SM36' Any basement Top slope of embankment or cuts of 2 feet or more vertical height Drainage systems and interceptor drains Any swimming pools Final earth grade (vertical) ➢ 15A NCAC 02T 0305( ) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications web a e ➢ If noncompliance with 02T.0305(f) or (g) see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ➢ See the Division's draft separation requirements for situations where separation cannot be meet Yes El No El N/A ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No ❑ N/A ➢ This would include Trout Buffered Streams per 15A NCAC 213.0202 4. Does the project require coverage/authorization under a 404 Nationwide or individual permits or 401 Water Quality Certifications? ® Yes ❑ No ➢ Information can be obtained from the 401 & Buffer Permittiniz Branch 5. Does project comply with 15A NCAC 02T 0105(c)(6) (additional permits/certifications)? Z Yes Per 15A NCAC 02T 0105(c)(6), directly related environmental permits or certification applications a being Iprepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permi(erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version,) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents 2. Professional Engineer's Certification: V I � S g— + attest that this application for (Professional Engineer's name from Application Item III.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. n North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): I, W AQLL -Q U 0 o ['� , T t, ,40 A61 F k attest that this application for (Signature Authority's name & title from Application Item I.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature:NN iz, — FORM: FTA 04-16 Page 5 of 5 , D-' W, R aD vi,sloe of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: City of Hickory Project Name for which flow is being requested: The Lodge at Hickory More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Henry Fork WWTP b. WWTP Facility Permit #: NCO040797 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flows are in MGD 9.0 1.89077 2.98375 0.0192 4.88937 54.37% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity, * (Firm / p f), Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow, MGD MGD Flow Capacity*** * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Hickory Collection System Downstream Permit Number: WQCS00020 Page 1 of 6 FTSE 10-18 III. Certification Statement: I Warren Wood certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Signing Official Signature Date City Manager Title of Signing Official Page 2 of 6 FTSE 10-18 3953 3952 \ I , `USGS U.S. DEU S. GEOL+ GIICAL SURIV YERIOR USrTopo 468 6TH AVE SW 469 NOT TO SCALE HICKORY QUADRANGLE NORTH CAROLINA CATAWBA CO. 7.5 AUNUTE SERIES Rrvxluetl bE ene Unitetl S[atet Geological Survey A .ev<ute. x.r.<.. tvt .vrunn werrarer anmrvy rmP Ntc NI•mrramr.,a�rNnn�rvav+kmUaearrarnuv.oe.rf ��m[• HICKORY. NC 206