Loading...
HomeMy WebLinkAboutNC0088897_Fact Sheet_20190322DocuSign Envelope ID: 86632DE6-B34C-42FE-9282-COF8F0006041 DENR / DWR / NPDES EXPEDITED FACT SHEET - NPDES PERMIT DEVELOPMENT NPDES Permit NCO088897 Emily DelDuco, Compliance & Expedited Permitting Unit / 919-707-9125 14 Nov 2018 Facility Information Applicant/Facility Name City of King Water Treatment Plant (WTP) Applicant Address P.O. Box 1132, King, NC 27021 Facility Address 6949 Donnaha Road, Tobaccoville, NC 27050 Permitted Flow (MGD) Not limited Type of Waste Water Plants and Water Conditioning Discharge — dechlorinated filter -backwash - Conventional WTP System Facility Class Physical Chemical 1 County Forsyth Permit Status Renewal Regional Office WSRO Stream Characteristics JFr Receiving Stream Old Richmond Creek Stream Classification WS-IV Stream Segment [12-79] Drainage basin Yadkin -Pee Dee Summer 7Q10 (cfs) 0.3 Subbasin 03-07-02 Winter 7Q10 (cfs) 0.3 Use Support No Data (ND) 30Q2 (cfs) 1.1 303(d) Listed Not Listed Average Flow (cfs) 4.5 State Grid C17NW IWC (%) 1 59.41% USGS Topo Quad Vienna, NC Changes to previous permit: - Added HUC to site description on supplement to cover page - Added regulatory citations - Updated eDMR language Facility Summary This facility is a conventional technology water treatment plant [coagulation, flocculation, sedimentation, and filtration] with discharge of wastewaters from media filter backwash and sedimentation basins with a design potable flowrate of 3.0 MGD and a maximum monthly average wastewater discharge of 0.283 MGD. Because the waste flow is >50k gpd, continuous flow monitoring is required. The facility consists of the following water and wastewater treatment units: • three (3) clear wells [0.150 MG, 0.230 MG and 1.0 MG] • high service pump station • generator • chemical storage tanks • a decant sludge holding tank [0.300 MG ] • wastewater pumping station • filter belt press • dechlorination equipment Since the issuance of the previous permit (2014), the facility completed Phase 2&3 of their WTP Improvements project. Construction included installation of new raw water intake, new raw water main, 8 Fact Sheet Renewal -- NPDES NCO082949 Page 1 DocuSign Envelope ID: 86632DE6-B34C-42FE-9282-COF8F0006041 new flocculators, new flash mixer, 2 new sedimentation basins with sludge collection system NaOCI building, 2 new additional filters, 2 new filter pumps with additional filtration well, new 16" transmission main. Previously the WTP had 3 chemical application points, now there are 5. Compliance History No enforcements. No violations since 2012. Daily Discharge Summary (parameter code 50050 - MGD) Oct 2014 - Oct 2018 (36mo) 2014 154 0.11 0.00 0.96 2015 253 0.11 0.00 0.55 2016 342 0.10 0.00 0.38 2017 357 0.08 0.00 0.3 2018 268 0.08 0.01 0.58 [ Maximum Monthly average flow (CAMONAVG) in past 36 months (Oct 2014 - Oct 2018) = 0.183 MGD (designated as Qw in RPA)] DMR Summary June 2014 - Nov 2018 Outfall Parameter 00070 - Turbidity 001 DIVIR N Obs 103 summary 2014-2018 Mean Minimum Maximum I 9.786 1.000 58.200 Reasonable PotentialTw n/a 00400 - pH 115 6.775 6.010 7.600 n/a 00951- Fluoride, Total (as F) 17 0.145 0.010 0.345 No 01042 - Copper, Total (as Cu) 17 0.006 0.005 0.010 No 01045 - Iron, Total (as Fe) 17 0.947 0.066 9.760 n/a 01092 - Zinc, Total (as Zn) 17 0.016 0.010 0.040 No 01105 - Aluminum, Total (as Al) 17 1.421 0.177 9.090 n/a 50050 - Flow, in conduit or thru treatment plant 1374 0.092 0.001 0.963 n/a 50060 - Chlorine, Total Residual 115 13.374 0.000 44.000 n/a CO530 - Solids, Total Suspended - Concentration 103 9.812 1.330 39.200 n/a CO600 - Nitrogen, Total - Concentration CO665 - Phosphorus, Total (as P) - Concentration 17 1.253 0.795 2.720 n/a 17 0.186 0.050 I 0.547 n/a LA TGP3B - Pass/Fail Static Renewal 22 7Day Chronic Ceriodaphnia Pass Pass pass n/a Toxicity - With an IWC >0.25%, this permit requires Chronic Whole Effluent Toxicity (WET) testing using Ceriodaphnia dubia to be performed as a 7-day pass/fail test at 59% effluent concentration. All tests this permit cycle (n=22) were passed. Fact Sheet Renewal -- NPDES NC0082949 Page 2 DocuSign Envelope ID: 86632DE6-B34C-42FE-9282-COF8F0006041 Renewal Summary —This permit reflects discharge at Outfall 001. Stream — Discharge from WTP for Outfall 001 is into Old Richmond Creek [Stream Segment 12-79]. The segment [12-79] from source to the Yadkin River is not currently listed as impaired in the 2012 North Carolina 303(d) List. RPA — A Reasonable Potential Analysis (RPA) was conducted on Copper, Fluoride, & Zinc effluent parameters data because Discharge Monitoring Reports (DMRs) reported concentration above method - detection levels (MDLs) for the past four and one half (4 1/2) years (June 2014 -November 2018). [See attached RPA summary sheets.] • Copper showed no reasonable potential to violate state water quality standards (WQS). • Fluoride did not show reasonable potential to violate state WQS; however, since the City backwashes with fluoridated finished water fluoride should be monitored quarterly with no limit. • Zinc showed no reasonable potential to violate state water quality standards (WQS). However, since Zinc orthophosphate has potential to be discharged, quarterly monitoring will remain in this permit. Fact Sheet Renewal -- NPDES NC0082949 Page 3 DocuSign Envelope ID: 86632DE6-B34C-42FE-9282-COF8F0006041 IWC Calculations City of King WTP NCO088897 Prepared By: Emily DelDuco, NPDES Program Enter Design Flow (MGD): 0.283 Enter s7Q10(cfs): 0.3 Enter w7Q10 (cfs): 0.3 Residual Chlorine Ammonia (NH3 as N) (summer) 7Q10 (cfs) 0.3 7Q10 (CFS) 0.3 DESIGN FLOW (MGD) 0.283 DESIGN FLOW (MGD) 0.283 DESIGN FLOW (cfs) 0.43865 DESIGN FLOW (cfs) 0.43865 STREAM STD (ug/L) 17.0 STREAM STD (mg/L) 1.0 UPS BACKGROUND LEVEL (l 0 UPS BACKGROUND LEVEL (mg/L) 0.22 IWC (%) 59.39 IWC (%) 59.39 Allowable Conc. (ug/1) 29 Allowable Conc. (mg/1) 1.5 Ammonia (NH3 as N) (winter) 7Q10 (CFS) 0.3 Fecal Limit 200/100ml DESIGN FLOW (MGD) 0.283 (If DF >331; Monitor) DESIGN FLOW (cfs) 0.43865 (If DF <331; Limit) STREAM STD (mg/L) 1.8 Dilution Factor (DF) 1.68 UPS BACKGROUND LEVEL (mg/L) 0.22 IWC (%) 59.39 Allowable Conc. (mg/1) 2.9 NPDES Servor/Current Versions/IWC 11 /15/2018 DocuSign Envelope ID: 86632DE6-B34C-42FE-9282-COF8F0006041 Table 1. Freshwater RPA - 95% Probability/95% MAXIMUM DATA Project Information Confidence Using Metal Translators of Concern POINTS = 58 DATA ENTRY Table 2. CHECK WQS Parameters REQUIRED Facility Name WWTP/WTP Class NPDES Permit Outfal I Flow, Qw (MGD) Receiving Stream HUC Number Stream Class ]CHECK IF HQW OR ORW WQS Paro1 Par02 Par03 Par04 Par05 Par06 Par07 Par08 Par09 Par10 Part Par12 Par13 Par14 Parts I Parts I Par17 I Par18 Par19 Par20 Par21 Par22 Par23 Par24 Name WQS Type Chronic Modifier Acute PQL Units City of King WTP PC 1 NCO088897 001 0.183 Old Richmond Creek 030401011007 WS-IVApply ❑WS Hardness WQC 7Q10s (cfs) 7Q10w (cfs) 30Q2 (cfs) QA (cfs) 1 Q1 Os (cfs) 0.30 0.30 Copper Aquatic Life NC 7.8806 FW 10.4720 ug/L 1.10 4.50 Fluoride Aquatic Life NC 1,800 FW ug/L 0.26 Effluent Hardness ------------- Upstream Hardness ------------- Combined Hardness Chronic ------------- Combined Hardness Acute 25 mg/L (Avg) ----------------- 25 mg/L (Avg) ---------------- 25 m /L ----------9------ I 25 m /L Data Source(s) ❑CHECK TO APPLY MODEL Zinc Aquatic Life NC 126.7335 FW 125.7052 ug/L 88897 RPA, input 12/6/2018 DocuSign Envelope ID: 86632DE6-B34C-42FE-9282-COF8F0006041 88897 RPA, input 12/6/2018 DocuSign Envelope ID: 86632DE6-B34C-42FE-9282-COF8F0006041 REASONABLE POTENTIAL ANALYSIS H1 Effluent Hardness Date Data BDL=1/2DL Results 1 25 25 Std Dev. 2 Mean 3 C.V. 4 n 5 10th Per value 6 Average Value 7 Max. Value 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 Use"PASTE SPECIAL Values" then "COPY" . Maximum data points = 58 F 1 25.0000 2 0.0000 3 1 4 25.00 mg/L 5 25.00 mg/L 6 25.00 mg/L 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 Upstream Hardness Date Data BDL=1/2DL Results 25 25 Std Dev. Mean C.V. n 10th Per value Average Value Max. Value Use"PASTE SPECIAL Values" then "COPY" . Maximum data points = 58 25.0000 0.0000 1 25.00 mg/L 25.00 mg/L 25.00 mg/L 88897 RPA, data -3- 12/6/2018 DocuSign Envelope ID: 86632DE6-B34C-42FE-9282-COF8F0006041 REASONABLE POTENTIAL ANALYSIS Pal Par13 Use"PASTE SPECIAL Use"PASTE SPECIAL Copper Values" then "COPY" Fluoride Values" then "COPY" . Maximum data . Maximum data points = 58 points = 58 Date Data BDL=1/2DL Results Date Data BDL=1/2DL Results 1 7/8/2014 < 5 2.5 Std Dev. 2.7881 1 7/3/2014 196 196 Std Dev. 116.7850 2 10/7/2014 < 5 2.5 Mean 4.1647 2 10/7/2014 345 345 Mean 117.8824 3 1/12/2015 6.8 6.8 C.V. 0.6695 3 1/12/2015 128 128 C.V. 0.9907 4 4/14/2015 10 10 n 17 4 4/14/2015 248 248 n 17 5 7/7/2015 6 6 5 7/7/2015 316 316 6 10/7/2015 < 5 2.5 Mult Factor = 1.49 6 10/7/2015 < 100 50 Mult Factor = 1.72 7 1/5/2016 < 5 2.5 Max. Value 10.00 ug/L 7 1/5/2016 < 100 50 Max. Value 345.0 ug/L 8 4/5/2016 < 5 2.5 Max. Fred Cw 14.90 ug/L 8 4/5/2016 < 100 50 Max. Pred Cw 593.4 ug/L 9 7/5/2016 < 5 2.5 9 7/5/2016 < 100 50 10 10/4/2016 < 5 2.5 10 10/4/2016 < 10 5 11 1/10/2017 9 9 11 1/10/2017 311 311 12 4/3/2017 < 5 2.5 12 4/3/2017 < 100 50 13 7/11/2017 < 5 2.5 13 7/11/2017 < 10 5 14 10/3/2017 < 5 2.5 14 10/3/2017 < 100 50 15 1/9/2018 9 9 15 1/9/2018 < 100 50 16 4/3/2018 < 5 2.5 16 4/3/2018 < 100 50 17 7/5/2018 < 5 2.5 17 7/5/2018 < 100 50 18 18 19 19 20 20 21 21 22 22 23 23 24 24 25 25 26 26 27 27 28 28 29 29 30 30 31 31 32 32 33 33 34 34 35 35 36 36 37 37 38 38 39 39 40 40 41 41 42 42 43 43 44 44 45 45 46 46 47 47 48 48 49 49 50 50 51 51 52 52 53 53 54 54 55 55 56 56 57 57 58 58 88897 RPA, data -4- 12/6/2018 DocuSign Envelope ID: 86632DE6-B34C-42FE-9282-COF8F0006041 REASONABLE POTENTIAL ANALYSIS Par21 Zinc Use"PASTE SPECIAL Values" then "COPY" Par22 . Maximum data points = 58 Date Data BDL=1/2DL Results 1 7/8/2014 < 10 5 Std Dev. 11.6079 1 2 10/7/2014 < 10 5 Mean 12.6471 2 3 1/12/2015 < 10 5 C.V. 0.9178 3 4 4/15/2015 30 30 n 17 4 5 7/7/2015 40 40 5 6 10/7/2015 20 20 Mult Factor = 1.67 6 7 1/5/2016 < 10 5 Max. Value 40.0 ug/L 7 8 4/5/2016 20 20 Max. Fred Cw 66.8 ug/L 8 9 7/5/2016 20 20 9 10 10/4/2016 < 10 5 10 11 1/10/2017 30 30 11 12 4/3/2017 < 10 5 12 13 7/11/2017 < 10 5 13 14 10/3/2017 < 10 5 14 15 1 /9/2018 < 10 5 15 16 4/3/2018 < 10 5 16 17 7/5/2018 < 10 5 17 18 18 19 19 20 20 21 21 22 22 23 23 24 24 25 25 26 26 27 27 28 28 29 29 30 30 31 31 32 32 33 33 34 34 35 35 36 36 37 37 38 38 39 39 40 40 41 41 42 42 43 43 44 44 45 45 46 46 47 47 48 48 49 49 50 50 51 51 52 52 53 53 54 54 55 55 56 56 57 57 58 58 Use"PASTE SPECIAL O Values" then "COPY" . Maximum data points = 58 Date Data BDL=1/2DL Results Std Dev. NO DATA Mean NO DATA C.V. NO DATA n 0 Mult Factor = N/A Max. Value N/A Max. Pred Cw N/A 88897 RPA, data -5- 12/6/2018 DocuSign Envelope ID: 86632DE6-B34C-42FE-9282-COF8F0006041 City of King WTP NCO088897 Freshwater RPA - 95% Probability/95% Confidence Using Metal Translators MAXIMUM DATA POINTS = 58 Qw (MGD) = 0.1830 WWTP/WTP Class: PC 1 1Q10S (cfs) = 0.26 IWC% @ 1Q10S = 52.17511266 7Q10S (cfs) = 0.30 IWC% @ 7Q10S = 48.59933179 7Q10W (cfs) = 0.30 IWC% @ 7Q10W = 48.59933179 30Q2 (cfs) = 1.10 IWC% @ 30Q2 = 20.50012648 Avg. Stream Flow, QA (cfs) = 4.50 IW%C @ QA = 5.929572607 Receiving Stream: Old Richmond Creek HUC 030401011007 Stream Class: WS-IV Outfall 001 Qw = 0.183 MGD COMBINED HARDNESS (mg/L) Acute = 25 mg/L Chronic = 25 mg/L PARAMETER NC STANDARDS OR EPA CRITERIA U) REASONABLE POTENTIAL RESULTS RECOMMENDED ACTION TYPE J a D Applied Chronic Acute n # Det. Max Pred Cw Allowable Cw Standard Acute: 20.07 No RP, Predicted Max z 50% of Allowable Cw - Copper NC 7.8806 FW(7Q10s) 10.4720 ug/L 17 5 14.90 defer toLTMP Chronic: 16.22 No RP , Predicted Max z 50% of Allowable Cw No value > Allowable Cw apply Quarterly Monitoring Acute: NO WQS No RP, Predicted Max < 50% of Allowable Cw - No Fluoride NC 1800 FW(7Q10s) ug/L 17 6 593.4 Monitoring required ------------- Chronic: 3,703.8 No RP, Predicted Max < 50%of Allowable Cw - No No value > Allowable Cw Monitoring required Acute: 240.9 No RP, Predicted Max < 50% of Allowable Cw - No Zinc NC 126.7335 FW(7Q10s) 125.7052 ug/L 17 6 66.8 Monitoring required Chronic: 260.8 No RP, Predicted Max < 50%of Allowable Cw - No No value > Allowable Cw Monitoring required 88897 RPA, rpa Page 6 of 6 12/6/2018 DocuSign Envelope ID: 86632DE6-B34C-42FE-9282-COF8F0006041 From: man, Jeff To: DelDuco, Emilv Cc: Hudson, Eric; Kaufman, Tammv Subject: FW: PWS Section Comment, Permit Renewal NC0088897 Date: Tuesday, January 15, 2019 12:48:13 PM Attachments: imaae001.Dna NC0088897 Draft 2018.Ddf NC0088897 DRAFT fact sheet RPA.Ddf imaae002.Dno Re: City King WTP wastewater, NCO088897 Forsyth County (renewal) Emily, We concur with issuing the permit provided the facilities are maintained and operated properly, the stated effluent limits are met, and discharge does not contravene designated water quality standards of receiving waters. Regards, Jeff Jeff H. Bryan, P.E. Assistant Regional Engineer Public Water Supply Section Department of Environmental Quality 336 776 9663 office 336 403 1092 mobile 0eff. bryan&ncdenr.gov Winston Salem Regional Office 450 W. Hanes Mill Road, Suite 300 Winston Salem, NC 27105 'Nothing Compares. Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: DelDuco, Emily Sent: Monday, December 17, 2018 4:23 PM To: Bryan, Jeff <jeff.bryan@ncdenr.gov> Subject: PWS approval DocuSign Envelope ID: 86632DE6-B34C-42FE-9282-COF8F0006041 Hi Jeff, NCO088897 / City of King WTP is a grade PC-1 facility in Forsyth County. Please send me any comments when you are able. Please note that we're transitioning to paperless communication. As such, NPDES will no longer send the separate approval memo for PWS comments on this permit draft. The email response from you (or another PWS contact) will suffice to document the draft permit review by PWS. Thanks for your help, and let me know if you have any questions. Emily DelDuco Division of Water Resources Department of Environmental Quality 919-707-9125 emily.delducoPncdenr.gov --- ?Nothing Compares, Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. DocuSign Envelope ID: 86632DE6-B34C-42FE-9282-00F8F0C06041 R:OY COOPER- NORTH iCAROLINA GovernorEnvironmental Quatilly t&CILAEL S- kEGAN Seoreffir�-' LINDA. CUTPEPPER Interim Director October 22, 2018 T. Scott Barrow, City Engineer City of King PO Box 1132 King, NC 27021-1132 Subject: Permit Renewal Application No. NCOOSS897 King WTP Forsyth County Dear Applicant: The Water Quality Permitting Section acknowledges the October 19, 2018 receipt of your permit renewal application and supporting documentation. Your application will be assigned to a permit writer within the Section's NPDES WW permitting branch. Per G.S. 150B-3 your current permit does not expire until permit decision on the application is made. Continuation of the current permit is contingent on timely and sufficient application for renewal of the current permit. The permit writer will contact you if additional information is required to complete your permit renewal. Please respond in a timely manner to requests for additional information necessary to allow a complete review of the application and renewal of the permit. Information regarding the status of your renewal application can be found online using the Department of Environmental Quality's Environmental Application Tracker at: https: //deq. nc.gov/permits-regulations/permit-guidance/environmental-a pplication-tracker If you have any additional questions about the permit, please contact the primary reviewer of the application using the links available within the Application Tracker. ec: WQPS Laserfiche File w/application Since%r--ellly, — Wren Thedford Administrative Assistant Water Quality Permitting Section afFn�m.mMtl� North Carolina Department of Environmental Quality I Division of Water Resources 1617 Mail Service Center I Raleigh, North Carolina 27699-1617 919-807-6300 DocuSign Envelope ID: 86632DE6-B34C-42FE-9282-COF8F0006041 CITY OF KING Jack Warren, Mayor Homer Dearmin, City Manager Scott Barrow, City Engineer P.O. Drawer 1132 King, NC 27021-1132 10/15/2018 Re: NPDES Permit renewal To Wren Thedford: 229 S. Main Street Telephone (336) 983-8265 Fax (336) 983-4675 RECEIVED/DENR/DWR OCT 19 2018 Water Resources Permitting Section The purpose of this letter is to request the renewal'-of;NPDES'P,ermit NCO088897. Since issuance of the previous permit, all construction of Phase 2 & 3r of7ourWatef[ Treatment, PlaAnt1mprovements project are complete and in operation. Construction included the4nstallation°of,a new raw^:water intake new raw water main, 8 new flocculators, a new flash mixer, 2 new sedimentation°^basins wth'sludge,-collection system; fyaOCI building, 2 new additional filters, 2 new filters pumps with an"ad`ditonal filtratioriwell=dnew,xh,igh service.pumpmg station, a 1.0 million gallon ground storage tank, a new- was-iewater�well-forriaddition^al storage�,'awnew-_16 transM.iission main leaving the plant and added onto the existing,Flab"building: yPleasetsee,attached,diagram.-This diagram also show the new chemical application points (prev16usly�we had,3� and: -how we,hay'p -5) \ ^Qur,siudge management plan consist of hauling the dewatered sludge from the belt=filterfipress to.th',e`,laridfill:., : ,,t, `_ y„ Sincerely, "'Al //� fx` �..,.. �` @. ., Z. x,•��;''.%M "�E�?3,"s �` ', �,b"`, w, .;'i <�f^'':'%, -,. ,k �" P7 _z-"-'"-•y'' ,s.'* '�`izr�.�'.�.^�yy;- •2``r,o �_"„e*--� �.���:�. '" �<i � `� �'�'.�k�# �! ��,''�� �� ��'z€ T. Scott Barrow [ City Engineer ; �� _ ,�° ;�, ,W"�", _ ia,aa _�_,,.,_ i, Y6.'S Y e'Qx x . j[ 4z <: " ts'q >sg€`II COUNCILMEN Mayor ProTem Rick McCraw — Charles Allen — Brian Carico — Wesley Carter DocuSign Envelope ID: 86632DE6-B34C-42FE-9282-COF8F0006041 NPDES PERMIT APPLICATION - SHORT FORM C - WTP For discharges associated with water treatment plants Mail the complete application to: NCDEQ / DWR / NPDES 1617 Mail Service Center, Raleigh, NC 27699-1617 NPDES Permit Number INCO088897 If you are completing this form in computer use the TAB key or the up - down arrows to moue from one field to the next. ,To check the boxes, click your mouse on top of the box. Otherwise, please print or type. 1. Contact Information: Owner Name City of King Facility Name City of King Water Treatment Plant Mailing Address P.O. Box 1132 City King State / Zip Code NC / 27021 Telephone Number (336)985-1104 Fax Number (336)983-4675 e-mail Address sbarrow@ci.king.nc.us 2. Location of facility producing discharge: Check here if same as above Street Address or State Road 6949 Donnaha Road City Tobaccoville State / Zip Code NC / 27050 County Forsyth 3. Operator Information: Name of the firm, consultant or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name Mailing Address City State / Zip Code Telephone Number ( ) Fax Number ( ) 4. Ownership Status: Federal ❑ State ❑ Private ❑ Public Page 1 of 3 Version 6/2017 DocuSign Envelope ID: 86632DE6-B34C-42FE-9282-COF8F0006041 NPDES PERMIT APPLICATION - SHORT FORM C - WTP For discharges associated with water treatment plants 5. Type of treatment plant: ® Conventional (Includes coagulation, flocculation, and sedimentation, usually followed by filtration and disinfection) ❑ Ion Exchange (Sodium Cycle Cationic ion exchange) ❑ Green Sand Filter (No sodium recharge) ❑ Membrane Technology (RO, nanofiltration) Check here if the treatment process also uses a water softener ❑ 6. Description of source water(s) (i.e. groundwater, surface water) Surface water from Yadkin River 7. Describe the treatment process(es) for the raw water: Conventional treatment: coagulation; flocculation; sedimentation; filtration and disinfection. S. Describe the wastewater and the treatment process(es) for wastewater generated by the facility: Filter backwash 9. Number of separate discharge points: 1 Outfall Identification number(s) 10. Frequency of discharge: Continuous ❑ If intermittent: Days per week discharge occurs: 7 Duration: 11. Plant design potable flowrate 3.0 MGD Backwash or reject flow 0.078 MGD Intermittent 2 hr 12. Name of receiving stream(s) (Provide a map showing the exact location of each outfall, including latitude and longitude): Old Richmond Creek; approx. lat 36 deg. 13' 22" long 80 deg. 25' 39" 13. Please list all water treatment additives, including cleaning chemicals or disinfection treatments, that have the potential to be discharged. Alum / aluminum sulfate Yes No X Page 2 of 3 Version 6/2017 DocuSign Envelope ID: 86632DE6-B34C-42FE-9282-COF8F0006041 NPDES PERMIT APPLICATION - SHORT FORM C - WTP For discharges associated with water treatment plants Iron sulfate / ferrous sulfate Yes No X Fluoride Yes No X Ammonia nitrogen / Chloramines Yes No X Zinc -orthophosphate or sweetwater CP1236 Yes X No List any other additives below: Sodium hypochlorite (NaOCl) Delpac (polyaluminum Chloride) Sodium thiosulfate (Na2S203) 14. Is this facility located on Indian country? (check one) Yes ❑ No 15. Additional Information: ➢ Provide a schematic of flow through the facility, include flow volumes at all points in the water treatment process. The plan should show the point[s] of addition for chemicals and all discharges routed to an outfall [including stormwater]. ➢ Solids Handling Plan 16. NEW Applicants Information needed in addition to items 1-15. ➢ New applicants are strongly recommended to contact a permit coordinator with the NCDENR Customer Service Center. Was the Customer Service Center contacted? ❑ Yes ❑ No ➢ Analyses of source water collected ➢ Engineering Alternative Analysis ➢ Discharges from Ion Exchange and Reverse Osmosis plants shall be evaluated using a water quality model. 17. Applicant Certification I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printe Person Sign' g Title of Applicant Date North Carolina General Statute 143-215.6 (b)(2) provides that: Any person who knowingly makes any false statement representation, or certification in any application, record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or by imprisonment not to exceed sic months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5 years, or both, for a similar offense.) Page 3 of 3 Version 6/2017 E32 0 W- DocuSign Envelope ID: 86632DE6-B34C-42FE-9282-COF8F0006041 From: Scott Barrow To: DelDuco, Emilv Subject: [External] RE: Request for information Date: Thursday, December 6, 2018 2:57:56 PM Attachments: image021.Dng NO-REPLY(a)CI. KING. NC. US 20181206 155336.Ddf • xternal email. Do not click links or open attachments unless verified. Send all suspicious email as an "J Good afternoon Emily, We use finished water for our backwash, which is why we use Application Point #5 for Sodium Thiosulfate. Attached please find a revised DMR, the Sludge Management Plan and a revised schematic. The schematic has been reduced to a 8.5 x 11", but I can send you a D Size version if you wish. Please let me know if you need anything further. Scott From: DelDuco, Emily[mailto:Emily. Del Duco@ncdenr.gov] Sent: Wednesday, December 05, 2018 10:45 AM To: Scott Barrow <sbarrow@ci.king.nc.us> Subject: Request for information Good Morning Scott, I am contacting you in regards to the NPDES permit renewal for City of King WTP / NC0088897. In order to avoid having copper monitoring frequency increased to monthly and having a limit set in place, DWR needs you to submit a modified DMR to correct the transcription error for the copper value we talked about. I noticed that your application is missing a sludge management plan, which I will need in order to renew your permit. Additionally, the flow schematic provided in the application is difficult to make out. Please provide a more legible flow diagram that shows flow path and points of chemical application. Lastly, to clarify, are you using finished water or well water to backwash? Please get this info to me as soon as you are able. Thanks, Emily DelDuco Division of Water Resources Department of Environmental Quality 919-707-9125 DocuSign Envelope ID: 86632DE6-B34C-42FE-9282-COF8F0006041 emily.delducot@ncdenr.gov A- 0-- Nothing Compares Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. NOTICE: Please be advised that this electronic mail transmission, along with any other electronic mail transmissions for which I am the recipient, is subject to disclosure in accordance with the North Carolina Public Records Act, N.C.G.S. 132-1 et. seq. unless the information contained therein falls within one of the limited number of exceptions to the North Carolina Public Records Act. Before transmitting any personal information or any information which you deem confidential, please consider that the contents of your electronic transmission, and my responses thereto, will be subject to disclosure to any and all persons, including the media, who may request a copy of my e-mails. DocuSign Envelope ID: 86632DE6-B34C-42FE-9282-COF8F0006041 CITYOF & Ilex.I N SLUDGE MANAGEMENT PLAN 201 gi is t 4m� tm it,iit Will con fal all p`rceswam;ewo(a IIamn.cili tg fiat"liti � and cttmipm,, mat its+; laditt F llpgrwc. to .the station, :`I 1 Eim, beli l regs 111ail� bIg IkIll �k4 1. hmw a 1 tl flwt r halt ailA 311611,gy eci'tttpieat, new 100,000 ,a -110 a. sludge dm,1111t:l7idken.in aa1 , & clflorina OD eclttil"emt, "tit nm., ti.,,it mh : now controls. mid electrical ma ific,ttiO MS, Pip(.IH. ve :X 14418JRMS and T.Cro les. will. lie �x).Aslruet d to c, rry ,�, sf wWelt; to the oxi ing,. i 6arge, l i t. Atee Di I iom t i ciamptlete, and the nevv pro. s,,; wastewater handling 61x,, tt' s <tirl ectolpt lem ave Oral pe, d NVI? vvill 1 : discbarging a ql a i 3lum ;Of 210..fi O (WI) or 'deunt Water '[P Old Richmond Cpc6 to aeco -c wmoc ifl-z a :new NIJ. E-S. permit, hip glow A411 only occtur ben an � li�� �c��tim���mtt,�fi.na� bdIn 18 :ctlrabied' tea 0:1 mm o at the Flud6 ` mid tltc e-N. hA :n filwi's mv, helot b.okwsaed, O[lt0wisc, Qnty 4,0t? g,<Ij mm ('A` Rttor Ncl:wos11 F€l,�.t and Nit pmss wx,4h water: will be dkch r M to the The dewal:ered sludge -grill be, i'r(misl orl 10 ilmc lily r -F Winston-Salem I a:nc.1filt i'ol° eti�t��a�.Eal; 6/2212012 DocuSign Envelope ID: 86632DE6-B34C-42FE-9282-COF8F0006041 N5 a € Jim € ffi � 3 p a Ry A � a ° £ ` a A -v7 gig' �U 'zJ F g���e s` Fy1 ���7:�5����h'� ~we a�lgs O i���a 3# j I ; � .q o. saab3 3I i j I Q -o d M .."-.�o . n h . 191 a c $c7y y = 11 a t0f] Go s � „s• � z e I _ Z wwz M� LpJ Z � + ��IIYY v ` x 111 I a y 3 lip, '3 DocuSign Envelope ID: 86632DE6-B34C-42FE-9282-COF8F0006041 EFFLUENT NPDES PERMIT # NCO088897 IIaT�Yil:ll:�e1�►C�a FACILITY NAME CITY OF KING WATER TREATMENT PLANT OPERATOR IN RESPONSIBLE CHARGE (ORC): Kenneth R. Gentry CERTIFIED LABORATORIES (1) R&A Labs CHECK BOX IF ORC HAS CHANGED Mail ORIGINAL and ONE COPY to: ATTN: CENTRAL, FILES DIVISION OR WATER QUALITY 1617 MAIL SERVICE CENTER RALEIGH, N.C. 27699-1617 001 MONTH January YEAR 2015 CLASS 1 COUNTY FORSYTH GRADE 1 PHONE 336-924-8363 (2) ❑ PERSON(S) COLLECTING SAMPLES Kenneth Gentry & Operators X W�.ex .21411 5 SIGNATURE OF OPERATOR IN RESPONSIBLE CHARGE DATE BY THIS SIGNATURE, I CERTIFY THAT THIS REPORT IS ACCURATE AND COMPLETE TO THE BEST OF MY KNOWLEDGE. 50050 00530 00400 50060 00070 01105 01045 01042 00600 00665 00951 01092 TCP3B FLOW EFF INF C3 W Z Z ce H Bi J Z � x C] a i3 �j W LU _ x M1 ? 0 0 a C V M Ii O Ciei.� O IW' IA Q, E 0 U 3 A a a Z J a Z 0 Z J N LU aI O �, _ a IL a 10 x O 5 � o o O O o o 0 0 O 0 H a H H Q 1— 1— F- F- U3 U HRS HRS Y/B1N MCD m L s7D.urs uzfL I NTU mgfL mgiL m -aL -gfL m P 7 F 2 830 8 Y 0.000 ,3� __.. _...�... _..�..�7777774W�- 4 N 0.233 �; .. 6 830 8 Y 0.000 8 0830 8 Y 0:242 _—MR— 10 0700 12 B 0.148 :ff-01�- 75. ..__�__: =�r .i�,�r� ., . 12 0830 8 Y 0.075 <.5 6.80 16 5.91 2.6 1.71 0.0068 <1.0 0.484 1.28 <.010 P ..�. - � -- m•m::, _ .........�._ .r�.�>mmr = ry=-:W::-�W- _�.::�..-; � .-:,n.,,:..m_. ...gym:: -« ^ 14 1240 5.5 Y 0.000 7F 7 . e m ^ 16 0830 8 Y 0.105 18 N 0.000 ;:ice: ® ^ A ^ 20 0830 8 Y 0.000 m ^ mm mm 22 0830 8 Y 0.073 ::. .. ..... r _^. ermn ^_m_ _ .� .r.� __ :ryW wp W._ ._w -�_ ._.._....�. w ___....._._._ raw0� � .. a....... _..._.._.__,_. .��.� � mom• W� :m _ m _..._ m 24 0700 12 B 0.000 m `°•":�2�...�:��-. :.:.................. ........�.,^ Vie: m..^ ....._ � m ..,,...��._'vYm _^ mG� d w�T m �aP��d � ^ � �^�V ^. 26 0830 8 Y 0.155 �80830^ .� W .._m_.8.� - ^® ^ 28Y� Y_�....0.113 m ^ mm m a m: ^ _ m ^ _ m m ^ o ^® ^ m ^m mmm^ m mm m ^ ^m m 30 0830 8 Y 0.000 �. . Ram _ _ .. ^ AVERAGE 0.045 5.4 11 5.33 0 75W 7EW WW MINIMUM 0.000 5.4 6 4,75 2.60 1.71 0,0068 0 0.484 1.28 0.00 0.000 MONTHLY AVG> LIMrr 30 ,. -... �,::-- .:_:....� -..�-m_._........�.-�..a�::::•v - memo..._._. �..^ ^m ^177— ...... DAILY MAXIMUM LIMIT to REPLICA DWQ MR-1 (01100) 11 twice per month 11 quarterly A numerical value of zero (one for Fecal Coliforms) was used for calculation on those numbers reported as "less than" (<). DocuSign Envelope ID: 86632DE6-B34C-42FE-9282-COF8F0006041 Winston-Salem Journal Advertising Affidavit Account Number 3376309 P.O Box 3159 Date Winston-Salem, INC 27102 December 21, 2018 NCDENRIDWQ/POINT SOURCE BRANCH 1617 MAIL SERVICE CENTER RALEIGH. NC 27699-1617 PO Number Order Category Description��� CITY OF KING 0000527232 Legal Notices PUBLIC NOTICE North Carolina Environmental Management Commission! NPDES Unit 1f PUBLIC NOTICE North Carolina Environmental Management Commission/ NPDES Unit 1617 Mail Service Center Raleigh, NC 27699-1617 Notice of Intent to Issue a NPDES Wastewater Permit The North Carolina Environmental Management Commission proposes to issue a NPDES wastewater dis- charge permit to the person(s) listed Publisher of the below. Written comments regarding the proposed permit will be accept- Winston—Salem Journal ed until 30 days after the publish date of this notice. The Director of the NC Division of Water Resources idersigned, a Notary Public of Guilford, North Carolina, duly commissioned. (DWR) may hold a public hearing d authorized by law to administer oaths, personally appeared the Publisher should there he a significant degree of public interest. Please mail com- ve who by being duly sworn deposes and says: that he/she is the Publisher's ments and/or information requests ve of the Winston-Salem Journal, engaged in the publishing ofa newspaper to DWR at the above address. Inter- ested persons may visit the DWR at nston-Salem Journal, published, issued and entered as second class mail in the 512 N. Salisbury Street, Raleigh. NC tan-Salcm, in said County and State: that he/she is authorized to make this to review information on file. Addi- tional information on NPDES permits sworn statement: that the notice or other legal advertisement, a copy of which and this notice may be found on our -reto, was published in the Winston-Salem Journal on the following dates: website: http://deq.nc.gov/about/di visions/water-resources/water- resources•permits/wastewater- branch/npdes-wastewater/public- 12/21/2018 notices,or by calling (919) 707.3601. NC0088897: The City of King re- quested renewal of permit for the City of Kinq WTP/Fnr-„Fi °ADO L - aid newspaper in which such notice. paper document, or legal advertisement - d was. at the time of each and every such publication, a newspaper meeting all the requirements and qualifications of Section 1-597 of the General Statutes of North +I Carolina and was a qualified newspaper within the meaning of Section 1-597 of the General Statutes of North Carolina. (signature ofperson making affidavit) Sworn to and subscribed before me the 21 day of December, 2018 l 1 IJ 1VJ LEA ANNE LAMB (Notary Public) ��t / NOTARY PUBLIC GUILFORD COUNTY, NC My Commission Expires 06-15-19 THIS IS NOT A BILL. PLEASE PAY FROM INVOICE. THANK YOU