Loading...
HomeMy WebLinkAboutWQ0000550_Inspection_20190329Permit: WQ0000550 SOC: County: Currituck Region: Washington Contact Person: Pat Irwin Compliance Inspection Report Effective: 05/01/17 Expiration: 04/30/22 owner: Currituck County Effective: Expiration: Facility: Currituck County Detention Center WWTF 441 Maple Rd Title: Maple NC 27956 Phone: 252-232-6061 Directions to Facility: From the intersection of Hwy 168 and NCSR 1246 (Maple Road) in Currituck county, proceed west on NCSR 1246 approximately 0.8 miles. The facility is located on the north side of NCSR 1246 System Classifications: SI, Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 03/26/2019 EntryTime: 10:15AM Primary Inspector: Dwight R Sipe Secondary Inspector(s): Reason for Inspection: Routine Permit Inspection Type: Wastewater Irrigation Facility Status: Compliant ❑ Not Compliant Question Areas: Exit Time: 11:45AM Phone: Inspection Type: Compliance Evaluation Treatment Flow Measurement -Effluent Treatment Flow Measurement -Influent Miscellaneous Questions Treatment Flow Measurement -Water Treatment Treatment Barscreen Use Records Record Keeping Treatment Lagoons End Use -Irrigation Treatment Influent Pump Station Treatment Disinfection Treatment Flow Measurement Standby Power (See attachment summary) Page 1 of 6 Permit: WQ0000550 Owner - Facility: Currituck County Inspection Date: 03/26/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: On 3/26/19 a compliance inspection of the wastewater treatment and disposal system for the Currituck Co. Detention Center (WQ0000550) was performed by R. Sipe w/ WQROS-WaRO. Also present were Glenn Vance and Rod Holley with Currituck Co. The inspection items included the following: Observed headworks area. Barscreen and influent punp station appeared well maintained and operational. Alarm for influent pump station was tested and found operational. The facultative lagoon appeared to be operating as designed. The freeboard was 2.6 feet. Some duckweed was present on the lagoon but only covered approx. 1/4 of its area. The synthetic liner was in adequate condition despite some tears present near the anchor point noted in previous inspections. The County has stated that they plan on closing the facility in the next few months. The flow meter was last calibrated on 9/27/18. The liquid chlorine disinfection system appears to be operating adequately. Last effluent results (11/18) were well below the Fecal Coliform limit. The spray fields appeared to be in adequate condition. According to the Mr. Holley, the irrigation system was last operated on 3/25/19 but only briefly to collect effluent samples. Prior to that, it was last operated on 3/8/19. Monitoring wells appeared to be in adequate condition. Record keeping and reporting were spot checked. NDMR, NDAR, and GW -59s for Nov. 2018 were compared with lab reports and found to be complete and accurate. Operational logs are kept electronically on the County network. The facility appeared to be in compliance with permit# W00000550 during the inspection. Page 2 of 6 Permit: WQ0000550 Owner - Facility: Currituck County Inspection Date: 03/26/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Type Yes No NA NE Single Family Spray, LR ❑ Reuse (Quality) ❑ Activated Sludge Spray, LR ❑ Infiltration System ❑ Activated Sludge Spray, HR ❑ Recycle/Reuse ❑ Single Family Drip ❑ Activated Sludge Drip, LR ❑ Lagoon Spray, LR Treatment Yes No NA NE Are Treatment facilities consistent with those outlined in the current permit? 0 ❑ ❑ ❑ Do all treatment units appear to be operational? (if no, note below.) 0 ❑ ❑ ❑ Comment: The facultative lagoon appeared to be operating as designed. The freeboard was 2.6 feet. Some duckweed was present on the lagoon but only covered approx. 1/4 of its area. The synthetic liner was in adequate condition despite some tears present near the anchor point noted in previous inspections. The County has stated that they plan on closing the facility in the next few months. Treatment Influent Pump Station Yes No NA NE Is the pump station free of bypass lines or structures? ❑ ❑ ❑ ❑ Is the general housekeeping acceptable? ❑ ❑ ❑ ❑ Are all pumps present? ❑ ❑ ❑ ❑ Are all pumps operable? ❑ ❑ ❑ ❑ Are floats/controls operable? ❑ ❑ ❑ ❑ Are audio and visual alarms available? ❑ ❑ ❑ Are audio and visual alarms operational? ❑ ❑ ❑ # Are SCADA/Telemetry alarms required? ❑ ❑ ❑ Are SCADA/Telemetry available? ❑ ❑ ❑ Are SCADA/Telemetry operational? ❑ ❑ ❑ Comment: Audio/visual alarms tested and found to be operational Treatment Flow Measurement -Influent Yes No NA NE Is flowmeter calibrated annually? ❑ ❑ 0 ❑ Is flowmeter operating properly? ❑ ❑ 0 ❑ Does flowmeter monitor continuously? ❑ ❑ 0 ❑ Does flowmeter record flow? ❑ ❑ 0 ❑ Does flowmeter appear to monitor accurately? ❑ 1:10 ❑ Page 3 of 6 Permit: WQ0000550 Owner - Facility: Currituck County Inspection Date: 03/26/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Comment: N/A Treatment Flow Measurement -Water Use Records Yes No NA NE Is water use metered? ❑ 1:10 ❑ Are the daily average values properly calculated? ❑ ❑ 0 ❑ Comment: N/A Treatment Flow Measurement -Effluent Yes No NA NE Is flowmeter calibrated annually? 0 ❑ ❑ ❑ Is flowmeter operating properly? 0 ❑ ❑ ❑ Does flowmeter monitor continuously? 0 ❑ ❑ ❑ Does flowmeter record flow? M ❑ ❑ ❑ Does flowmeter appear to monitor accurately? ❑ ❑ ❑ ❑ Comment: Flow meter was last calibrated on 9/27/18 Standby Power Yes No NA NE Is automatically activated standby power available? ❑ ❑ ❑ Is generator tested weekly by interrupting primary power source? ❑ ❑ ❑ Is generator operable? ❑ ❑ ❑ Does generator have adequate fuel? 0 ❑ ❑ ❑ Comment: Standby power provided by -generators at the adjacent RO WTP. Treatment Barscreen Yes No NA NE Is it free of excessive debris? 0 ❑ ❑ ❑ Is disposal of screenings in compliance? 0 ❑ ❑ ❑ Are the bars spaced properly? 0 ❑ 1:11:1 Is the unit in good condition? M ❑ 1:10 Comment: No issues noted. Treatment Disinfection Yes No NA NE Is the system working? ❑ ❑ ❑ Do the fecal coliform results indicate proper disinfection? ❑ ❑ ❑ Is there adequate detention time (-30 minutes)? ❑ ❑ ❑ Is the system properly maintained? ❑ ❑ ❑ If gas, does the cylinder storage appear safe? ❑ ❑ ❑ Is the fan in the chlorine feed room and storage area operable? ❑ ❑ ❑ Is the chlorinator accessible? ❑ ❑ ❑ If tablets, are tablets present? ❑ ❑ ❑ Are the tablets the proper size and type? ❑ ❑ ❑ Is contact chamber free of sludge, solids, and growth? ❑ ❑ ❑ Page 4 of 6 Permit: WQ0000550 Owner - Facility: Currituck County Inspection Date: 03/26/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine If UV, are extra UV bulbs available? ❑ ❑ ❑ If UV, is the UV intensity adequate? ❑ ❑ ❑ # Is it a dual feed system? ❑ ❑ ❑ Does the Stationary Source have more than 2500 lbs of Chlorine (CAS No. 7782-50-5)? ❑ ❑ ❑ If yes, then is there a Risk Management Plan on site? ❑ ❑ ❑ If yes, then what is the EPA twelve digit ID Number? (1 000 ) If yes, then when was the RMP last updated? Comment: The liquid chlorine disinfection system appears to be operating adequately. Last effluent results (11/18) were well below the Fecal Coliform limit. Record Keeping Yes No NA NE Is a copy of current permit available? ❑ ❑ ❑ Are monitoring reports present: NDMR? ❑ ❑ ❑ NDAR? ❑ ❑ ❑ Are flow rates less than of permitted flow? ❑ ❑ ❑ Are flow rates less than of permitted flow? ❑ ❑ ❑ Are application rates adhered to? ❑ ❑ ❑ Is GW monitoring being conducted, if required (GW -59s submitted)? ❑ ❑ ❑ Are all samples analyzed for all required parameters? ❑ ❑ ❑ Are there any 2L GW quality violations? ❑ ❑ ❑ Is GW -59A certification form completed for facility? ❑ ❑ ❑ Is effluent sampled for same parameters as GW? ❑ ❑ ❑ Do effluent concentrations exceed GW standards? ❑ ❑ ❑ Are annual soil reports available? ❑ ❑ ❑ # Are PAN records required? ❑ ❑ ❑ # Did last soil report indicate a need for lime? ❑ ❑ ❑ If so, has it been applied? ❑ ❑ ❑ Are operational logs present? ❑ ❑ ❑ Are lab sheets available for review? ❑ ❑ ❑ Do lab sheets support data reported on NDMR? ❑ ❑ ❑ Do lab sheets support data reported on GW -59s? ❑ ❑ ❑ Are Operational and Maintenance records present? ❑ ❑ ❑ Were Operational and Maintenance records complete? ❑ ❑ ❑ Has permittee been free of public complaints in last 12 months? ❑ ❑ ❑ Is a copy of the SOC readily available? ❑ ❑ ❑ No treatment units bypassed since last inspection? ❑ ❑ ❑ Page 5 of 6 Permit: WQ0000550 Owner - Facility: Currituck County Inspection Date: 03/26/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Comment: Record keeping and reporting were spot checked. NDMR, NDAR, and GW-59s for Nov. 2018 were compared with lab reports and found to be complete and accurate. Operational lops are kept electronically on the County network. End Use-Irrigation Yes No NA NE Are buffers adequate? 0 ❑ ❑ ❑ Is the cover crop type specified in permit? ❑ ❑ ❑ Is the crop cover acceptable? ❑ ❑ ❑ Is the site condition adequate? ❑ ❑ ❑ Is the site free of runoff / ponding? ❑ ❑ ❑ Is the acreage specified in the permit being utilized? ❑ ❑ ❑ Is the application equipment present? ❑ ❑ ❑ Is the application equipment operational? ❑ ❑ ❑ Is the disposal field free of limiting slopes? ❑ ❑ ❑ Is access restricted and/or signs posted during active site use? ❑ ❑ ❑ Are any supply wells within the CB? ❑ ❑ ❑ Are any supply wells within 250' of the CB? ❑ ❑ ❑ How close is the closest water supply well? ❑ ❑ ❑ Is municipal water available in the area? ❑ ❑ ❑ # Info only: Does the permit call for monitoring wells? ❑ ❑ ❑ Are GW monitoring wells located properly w/ respect to RB and CB? ❑ ❑ ❑ Are GW monitoring wells properly constructed, including screened interval? ❑ ❑ ❑ Are monitoring wells damaged? ❑ 0 ❑ ❑ Comment: The spray fields appeared to be in adequate condition. According to the Mr. Holley, the irrigation system was last operated on 3/25/19 but only briefly to collect effluent samples. Prior to that, it was last operated on 3/8/19. Monitoring wells appeared to be in adequate condition. Page 6 of 6