Loading...
HomeMy WebLinkAboutNCG550489_Inspection_20190328ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Director Mr. Hal Bond P.O. Box 714 Taylorsville, NC 28681 Dear Mr. Bond: NORTH CAROLINA EnW&onMerk1g1 Qegorrty March 28, 2019 Subject: Compliance Evaluation Inspection 295 Taylorsville Beach Court Certificate of Coverage No. NCG550489 Alexander County Enclosed is a copy of the Compliance Evaluation Inspection for the inspection conducted at the subject facility on March 27, 2019, by Ori Tuvia. Your cooperation during the site visit was much appreciated. Per your request please see attached Change of Ownership form. The report should be self-explanatory; however, should you have any questions concerning this report, please do not hesitate to contact Ori Tuvia at (704) 235-2190, or at ori. tuvia(ancdenr. gov. Sincerely, Docu Signed by: A4,44W H P44,f for F161FB69A2D84A3... W. Corey Basinger Regional Supervisor Mooresville Regional Office Division of Water Resources Cc: NPDES, MRO Files (Laserfiche) State of North Carolina I Environmental Quality I Water Resources I Water Quality Regional Operations Mooresville Regional Office 1 610 East Center Avenue, Suite 3011 Mooresville, North Carolina 28115 704 663 1699 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN I 2 15 I 3 I NCG550489 111 12 I 19/03/27 I17 18 I S J 19 L G] 201 I 211111 1 1 I I I I II I I I I I I I I I I I I 1 I I I I I I I I I I II I I I I I f6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 1.0 70 71 [„ I 72 n 73 L_LJ74 751 u u I I I I I I I80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES oermit Number) 01:00PM 19/03/27 13/08/01 295 Taylorsville Beach Court 295 Taylorsville Beach Ct Exit Time/Date Permit Expiration Date Taylorsville NC 28681 01:45PM 19/03/27 18/07/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Hal L Bond,PO Box 714 Taylorsville NC 28681/// No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Operations & Maintenance Records/Reports Self -Monitoring Program Sludge Handling Disposal 0 Facility Site Review Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date DocuSigned by: Ori A Tuvia MRO WQ//704-663-1699/ 3/28/2019 =� Signature of Management Q A Reviewer Agency/Office/Phone and F x Num°liess9"ea by. Date ��H P+.xt.t�. 3.28.19 Andrew Pitner MRO WQ//704-663-1699 Ext.21 t161FB69A2D84A3... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type NCG550489 I11 121 19/03/27 117 18 JCJ Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Page# Permit: NCG550489 Owner - Facility: 295 Taylorsville Beach Court Inspection Date: 03/27/2019 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ 0 ❑ application? Is the facility as described in the permit? 0 ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ 0 ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: The subject permit will expire at October 31, 2020. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? 0 ❑ ❑ ❑ Is all required information readily available, complete and current? 0 ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? 0 ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? ❑ ❑ 0 ❑ Is the chain -of -custody complete? 0 ❑ ❑ ❑ Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported CM Are DMRs complete: do they include all permit parameters? ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ ❑ on each shift? Is the ORC visitation log available and current? ❑ ❑ 0 ❑ Is the ORC certified at grade equal to or higher than the facility classification? ❑ ❑ 0 ❑ Is the backup operator certified at one grade less or greater than the facility classification? ❑ ❑ 0 ❑ Is a copy of the current NPDES permit available on site? ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ❑ ❑ 0 ❑ Comment: Records were well organized and maintained. Water Tech Inc. preform the required sampling (last done on 3/29/2017), no sampling aas done since than due to the permitee no longer livina in the house so there been no flow. Operations & Maintenance Yes No NA NE Page# 3 Permit: NCG550489 Owner - Facility: 295 Taylorsville Beach Court Inspection Date: 03/27/2019 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Septic Tank Yes No NA NE (If pumps are used) Is an audible and visual alarm operational? ❑ ❑ 0 ❑ Is septic tank pumped on a schedule? 0 ❑ ❑ ❑ Are pumps or syphons operating properly? ❑ ❑ 0 ❑ Are high and low water alarms operating properly? ❑ ❑ 0 ❑ Comment: Septic tank is pumped regularly. last pumped on April 20107. Sand Filters (Low rate) Yes No NA NE (If pumps are used) Is an audible and visible alarm Present and operational? ❑ ❑ 0 ❑ Is the distribution box level and watertight? ❑ ❑ ❑ Is sand filter free of ponding? 0 ❑ ❑ ❑ Is the sand filter effluent re -circulated at a valid ratio? ❑ ❑ 0 ❑ # Is the sand filter surface free of algae or excessive vegetation? ❑ ❑ 0 ❑ # Is the sand filter effluent re -circulated at a valid ratio? (Approximately 3 to 1) ❑ ❑ 0 ❑ Comment: The sand filter is covered in soil. No wetness was observed in the area. Disinfection -Tablet Yes No NA NE Are tablet chlorinators operational? 0 ❑ ❑ ❑ Are the tablets the proper size and type? 0 ❑ ❑ ❑ Number of tubes in use? 2 Is the level of chlorine residual acceptable? ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? 0 ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? ❑ ❑ 0 ❑ Comment: Using USA Blue Book, Cal Hypo Giant Tabs. De -chlorination tablets are also been used. Page# 4