Loading...
HomeMy WebLinkAboutWQ0040635_Application (FTSE)_20190107State of North Carolina WR Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 -- FAST TIC;LCK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: IL L, (to be cumpkird by Mft) All items trust he completed or theapplicitioll will be returned I. APPLICANT INFORMATION: I. Applicant's name: Town of Nashville (company, municipality, I IOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ Stat&County ® 14lunicip,tl ❑ Other 3. Signature authority's name: lames Baines per 15A NCAC 02T .0106(b) Title: Public Works Director 4. Applicant's mailing address: P.O. Box 987 City: Nashville State: NC Zip. 27856-__ 5. Applicant's contact information: Phone number: 252) 459-3962 Email Address: jamey.baines-iitownofnashvillenc-,ov yti H. PROJECT INFORMATION: I. Project name: Aviation Subdivision Cf � 2. Application/Project status: ® Pro p ( osed New Permit) ❑Existing Pennitlf rojec[ °��' 0_ —. IFa modification, provide the existing permit number: WQ00_ and issued date: _ ^o ►ti o IFne%v construction but part of a master planr provide the existing permit number: WQ00 LQ 3. County where project is located: Nash ° �4 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.973662 , Longitude:-77.956744' p 5. Parcel ID (if applicable): 38012090I859 (or Parcel ID to closest downstream sewer) Ill. CONSULTANT INFORMATION: I. Professional Engineer. J. Michael Stocks License Number: 19843 Firm: Stocks Engineering. P.A. Wailing address: PO Box 1 108 City: Nashville State: NC Zip: 27856-__ Phone number: 252 459-8196 Finail Address: ins tocksOwstocksengineerin_.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Tar River Regional Wastewater'I-reatment Plant Permit Number: NC030317 Owner Name: City of Rocky Mount. V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQDownstream (Receiving) Sewer Size- 8 inch System Wide Collection System Permit Number(s) (if applicable): WQCS0039066 Owner Name(s): Town of Nashville FOR�,M: FTA 04-16 Page I of5 Vl. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes []No ®N'A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes [-]No ©N.A 3. If the Applicant is a Home Property Owners' Association, has an Operational Agreement (FORM: HOA) been attached? ❑ Yes ❑No ©NI:A 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation,'service ❑ Flotel and/or Motels ❑ School preschool day care ❑ Medical! dental J veterinary facilities ❑ Swimming Pool 'Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool?Filter Backwash ❑ Businesses ;' offices ;' factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic, -'Commercial % Commercial _ % Industrial (See 15A NCAC 02T .0 f 03(20)) 4 Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Has a flow reduction been approved under 15A NCAC 02T .01 14(0? []Yes ©No If ves. provide a coov of flow reduction approval fetter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow''' No. of Units Flow Residential Lots 360 gal/day 11 3,960 GPD gal/ GPD gall GPD gall GPD gall GPD gall GPD Total 3,960 GPD a See 15A NCAC 02T .01 Id b d e 1 and e 2 for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A4). b Per 15A NCAC 02T .01 14(c), design Floe rates for establishments not identified [in table 15A NCAC 02T.01 141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 3,9.60 GPD (per 15A NCAC 02T .0114) ;- Do not include future Flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer «ith no new flow expected ❑ Other (Explain): __ FORM: FTA 04-16 Page 2 of 5 VI I. GRAVITY SEINER DESIGN CRITERIA (If Applicahle) - 02T .0305 & i<IDC Gravitv Sewers): I. Summarize ;_ravity setker to be permitted -- Size (inches) I Length (feet) I Material 1 8 1 283 1 SDR-35 PVC Section II 3 III of the NIDC for Penmitting ol'Gravity Sewers contains information related to design criteria Section III contains information related to minimum slopes for gravity sewer(s) O�ersizing lines to meet minimum slope requirement is not allowed and a �iolalion of the N1DC Vlll. I'Ui'vIl' STATION DESIGN CRITERIA (If Applicable)— 02T A305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT I. Pump station number or name- ?. Approximate Coordinates (Decimal Degrees); Latitude; _.. Longitude: -� 3. Design flow of the pump station: millions ;gallons per dap (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDI-1) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with I3A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(13) Required for all pump stations " ith an average daily now -reater than or equal to 13,000 gallons per day Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02-r .0305(h)(1)(C) or ❑ Portable pumping unit «ith plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): It shall be demonstrated to the Division that the portable source is o%tined or contracted by the applicant (draft agreement) and is compatible with the station. If the portable power source or pump is dedicated to multiple pump stations. an evaluation of all the pump station; storage capacities and the rotation schedule of the portable power source: or pump, including travel timelrames, shall be provided in the case of a multiple station power outage, rORM; r•rA 04-16 Page 3 of IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T.0305(f)): I. Does the project comply with all separations found in 15A NCAC 02T .0305(f) & 6+_) %- 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: ® Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines vertical - reclaimed over sewer) 18 inches Reclaimed water lines Qiorizontal - reclaimed over sewer) 2 feet "Any private or public water supply source, including any wells, WS-1 waters of Class I or Class 11 impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation) and wetlands (see item IX? 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainages stems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches 15A NCAC 02T.0305(a) contains alternatives where separations in 02T.0305(f) cannot be achieved. ". "Stream classifications can be identified using the Division's NC Surface- Water_ Classifications webpage f noncompliance with 02T.0305(f) or (a). see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes ❑ No > See the Division's draft separation requirements for situations where separation cannot be meet No variance is required if the alternative design criteria specified is utilized in design and construction As built documents should reference the location of areas effected 3. Does the project comply with all setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No :- This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project comply with an individual 404 Pennit or any 401 Certifications? ® Yes [:]No Wetland -related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters Information can be obtained from the 401 & Buffer Permittin_ Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes [:]No Per 15A NCAC 02T.0105(c)(61, directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, slortmvater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). I ligh priority lines shall he inspected by the perrifttee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the perinilee's individual System -Wide Collection permit. i-ORNI: I TA 0.1-16 Pa+_e 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria latest version as applicable? ® Yes ❑ No If No, complete and submitthe Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Anoroval of the request is required prior to submittal of the Fast Track Application and supportine documents. 2. Professional Engineer's Certification: I, (Professional s name from Application item 1II.1.) attest that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143 215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. : North Carolina Professional Engineer's seal, signature, and date: ♦♦,�',�,� C,A ^'`4f,, OF�CSS�p��,• i SEAL r 19843 a ~ % � • �%-i1VG 1 Nl�� --' •4� • � ✓`� LK l ,g S�O`titi♦ 3. Applicant's Certification per 15A NCAC 02T . I06(b): �_At '1 es Zc; nes j_ 271'/7Zn:::0r e3 &�h'e- k1;rrk5 , attest that this application for (Signature Authority's name & title from Application Item I.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 1 i3-215.6A and 143215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signatu . ,� �P/�� Date: 1/7 FORM: FTA 04-16 Page 5 of Sewer Project Narrative For Aviation Subdivision Aviation Subdivision is a subdivision in Nashville, NC that will consist of 11 residential lots. The sewer extension design will serve lots 6-11. Lots 1-5 will tie in to the existing 8" gravity sewer main. Aviation subdivision, is located off Aviation Avenue, just south of US 64 in Nashville. It will consist of 100% domestic flow. The sewer system will be constructed of approximately 283 LF of 8-inch SDR-35 PVC sewer pipe. Each residential lot served by this sewer service will require 360gal/day. The extension will serve 6 Iots which makes the total projected flow for this extension 2,160 GPD. The wastewater treatment plant facility that will be handling this flow is the Tar River WWTF (Permit # NC 0030317). The permitted flow for the WWTF is 21.0 MGD (NPDES). Env�Connental Qua1�tY -tic I)CO A h�tegt0°al Gff te° �tel� 4 , 't . ARTMENT OF THE INTERIOR The National Map S. GEOLOGICAL SURVEY US Topo 32 sr3o° a 2 _ '33 34 35 —\� - FRE RICK CdO PER n -Po tRES DR 4 FRb - - ,�� _ _ r'"` f • "'� - 1.� �• _ _ �'1p 'r _ 1. E iZ 1 : SIT64 E °5ti s - n h� �F Jar Pad, �• , .. E c� 94 l ' WESTERN AVE �a ; yGR�Hsr roHsP — EASTERN AVE 1003 Alt �a EGgE + a� 64 0 W RAILROAD it - FNST EQP 2 I OLD WHITE OAK RD •; , NASHVILLE 1 Dakland 1� Aso r Cem Zda 13 � W 1� 1fA�r �r f GOLFERS LN ODE- lp G ! Q TAN84RR OR NC Dept of Environmental Quality State of North Carolina DD JAM 7 2019 Department of Environmental Quality t Division of Water Resources Division of Miter Resources HoWl6&111 cQXWce for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: Town of Nashville Project Name for which flow is being requested: Aviation Subdivision More than one FTSE may be required for a single project if the owner of the IVFVTP is not responsihle for all pump stations along the route of the proposed wastewaterflow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Ci of Rocky Mount - Tar River Regional WWTP b. WWTP Facility Permit #: NCO030317 C. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility All flows are itt MGD 21.00 0.536 10.83 0.00216 11.368 h. Percent of permitted flow used 54.13 II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) Design Pump Average Daily Approx. Station Firm FIow*" Current Avg. (Name or Capacity, * (Firm i pn, Daily Flow, Number) MGD MGD MGD 97 Lift St. 30.0 12.0 6.5 (C) (D)=(B+C) (E)=(A-D) Obligated, Not Yet Total Current Tributary Flow Plus Daily Flow, Obligated Available MGD Flow Capacity*** 0.2 6.7 5.3 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WVVTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Tar River Regional Downstream Permit Number: NC 0030317 Page I of 6 FTSE 04-16 III. Certification Statement: I William Brad Kerr certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates, ptance of this wastewater flow. } z _ �- Dare Page 2 of 6 FT'CF [1d_1 f _ State of North Carolina Department of Environmental Quality Lkik Division of Water Resources Divislon of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: Town of Nashville Project Name for which flow is being requested: Aviation Subdivision More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: City of Rocky Mount - Tar River Regional WWTP b. WWTP Facility Permit M NCO030317 All flows are in MGD_1 c. WWTP facility's permitted flow 21.00 N d. Estimated obligated flow not yet tributary to the WWTP 0.0536 e. WWTP facility's actual avg. flow 10.83 f. Total flow for this specific request .00216 Q g. Total actual and obligated flows to the facility 11.368 ° h. Percent of permitted flow used 54.13 II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)—(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity, * (Firm / pf), Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pi) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Unknown Downstream Permit Number: Unknown Page 1 of 6 FTSE 04-16 III. Certification Statement: I James Baines certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. I Signing Official Signature ate Page 2 of 6 FTSE 04-16 LE YrER OF TRANSMIrF rAL Stocks Engineering, PA PO Box 1108 J. Michael Stocks, PE Nashville, NC 27856 252.903.6891 252.459 8196 To: Ted Cashion NCDEQ-DWQ 3800 Barrett Drive, Suite 101 Raleigh, NC 27609 Phone: 919-791-4252 1 Overnight No Yes We are sending you the following J. Kevin Varnell 252,382. 0012 Job No. 2018-057 Job Name: Aviation Subdivision Date: 113119 Sent By: Ethan Averette ❑ EC Plans ❑ Prints/Plans ❑ Construction Plat ❑ Site Plan Drawings ❑ Computer Disk ❑ Contracts x Permit Applications ❑ Site Work Calculations ❑_ These are transmitted as checked below. x For Approval ❑ As Discussed ❑ For Your File ❑ As Requested ❑ For Your Use ❑ For Review and Comment ❑ For Your Signature, then return to., _ Copies Date IDescription 2 1-3-19 f Fast Track Sewer Application 2 1-3-19 Flow Tracking/Acceptance for Sewer Extension Applications 2 1-3-19 USGS Map with location of site shown 2 1-3-19 Street Map of Surrounding Area n d 2 1-3-19 Sewer Narrative 2• t= 1 1-3-19 Permit Fee Check ilr, —.j S r co c 1 1-3-19 Sewer Plan and Profile p p Remarks Copies To: Deck, Erin M From: Kevin Varnell <kvarnell@stocksengineering.com> Sent: Monday, February 18, 2019 3:47 PM To: Deck, Erin M Subject: FW: [External] Aviation Subdivision :CAUTION: External emall. Do not click llnks-or openn-attachmerts unless you verify. Send: ail, susplcious-email as an attachmenfio .t Ireaor#.saamnc:aow Erin, See below from the City of Rocky Mount. I will forward the email from Jamey Baines as soon as I receive it. Sincerely, J. Keviwvarvttl, ENGINEERING u"' !A5# r G BOX 11GA WA5 Am Lr, r, C 2795u PHME +500- StOG x.vtr '.T;1c•:�EtiC.;tEEF�riu c�v. Our Competitive Advantage We build long term relationships with our clients by being Creative, Personable, Accessible, Responsive, and Knowledgeable. From: Donald Perry <donald.perry@roekymountne.gov> Sent: Monday, February 18, 2019 3:42 PM To: Kevin Varnell <kvarnell@stocksengineering.com> Cc:'jamey.baines@townofnashvillenc.gov' <jamey.baines@townofnashvillenc.gov>; Brad Kerr <brad.kerr@rockymountnc.gov>; Negrete Silver <negrete.silver@rockymountnc.gov> Subject: RE: [External] Aviation Subdivision Kevin, We acknowledge and accept the additional 1,800 GPD in flow. This brings this request to a total of 3,960 GPD in flow. Thanks, Donald M. Perry, PE, CPESC Assistant City Engineer — Water Resources City of Rocky Mount t: 252.972.1122 'Please note that email sent to and from this address is subject to North Carolina Public Records Laws and may be disclosed to third parties, From: Kevin Varnell<kvarnell@stocksengineerine.com> Sent: Monday, February 18, 2019 2:10 PM To: Donald Perry <donald. er rock mountnc. ov> Cc:'jamey.baines@townofnashvillenc.gov' <jamen.baines@to_wnofnashvillenc.eov> Subject: FW: [External] Aviation Subdivision Donald /Jamey, We have had to revise the Sewer Permit for Aviation to show the lots that are connecting to the existing sewer. See the email chain below for more information. Therefore the total flow now is 3,960 GPD or 1,800 GPD more than the original permit. DEQ is good with correcting with the revised application without new signatures, so long as you both will send an email acknowledging the additional 1,800 GPD in flow. Would both of you mind replying back to this email with an acceptance of the flow? Sincerely, J. K.ev%w varvl41. i ENGINEERING am. LAS: WAS�w4r".qu 5:11CL1 Po Box ttua NASl+Y�4LE, ��C 2755f, +'HEYI«. (257) a54»d1�jb WOM VocXSENDNEER t1 G COu Our Competitive Advantage We build long term relationships with our clients by being Creative, Personable, Accessible, Responsive, and Knowledgeable. From: Deck, Erin M <erin.deck@ncdenr.gov> Sent: Monday, February 18, 2019 1:47 PM To: Kevin Varnell <kvarnell@stocksen into eering com> Cc: Mike Stocks<mstocks@stocksensineerins.com>;'jamey.baines@townofnashvillenc.gov' <iame .baines townofnashvillenc. ov> Subject: RE: [External] Aviation Subdivision Good Afternoon, i can use the revised pages as long as the permittee agrees to the changes. We will also need something from the City of Rocky Mount saying they will accept the additional proposed flow. Once those have been received, I can more forward drafting the permit. Thank you. Erin Deck Department of Environmental Quality Division of Water Resources Raleigh Regional Office Office: 919-791-4258 Nothing Compares Nt + Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Kevin Varnell mailto:kvarnell@stocksensineering.coml Sent: Monday, February 18, 2019 11:40 AM To: Deck, Erin M <erin.deck ncdenr. ov> Cc: Mike Stocks <mstocks@stocksengineering.com>;'Jamey.baines@townofnashvillenc.gov' <lamev.baines@townofnashvillenc.gov> Subject: [External] Aviation Subdivision !:CAUTION: External email. Do notclick links or open attachments unless: you. verify. Send all suspicious email as-an;attachment to re vrt.s a nc v Erin, The Subdivision does consist of 11 lots total. However, Lots 1-5 are actually service taps off of an existing sewer line. I have no idea if any future development flow had been accounted for in a previous permit as this line has been installed for some time. Therefore, I would think that it needs to be added into this permit to account for the flow. All houses are proposed to be 3 bedroom or less. Therefore the total flow requested would be 360 GPD for 11 Lots = 3,960 GPD. Section V1.6 was inadvertently checked Yes and it should have been checked "No". We have revised the Word file for the permit and attached it. Can we simply replace the revised pages with the current permit you have? Let me know if you have any questions or concerns. Sincerely, J. K.ev%m varyLetl, 1 ENGINEERING 601 tASr WASHINGION 57REC1 PO BOx IICa NASHVILLE. %C. 27+M PFONE (252) A59-8196 ZworSTOC*.SEWNEC9 K;W Com Our Competitive Advantage We build long term relationships with our clients by being Creative, Personable, Accessible, Responsive, and Knowledgeable. From: Deck, Erin M <erin.deck@ncdenr.gov> Sent: Monday, February 11, 2019 2.25 PM To: lame .baines townofnashvillenc. ov• Mike Stocks <mstocks@stocksengineering.com> Cc: Robinson, Jason <iason.t.robinson@ncdenr.gov_> Subject: Aviation Subdivision Good afternoon, We are in the process of reviewing the subject application and require some information prior to drafting the permit. The narrative states that the subdivision consists for 11 residential lots; however the application is only for lots 6- 11. Has the flow associated with lots 1-5 been accounted for in a previous permit? if so, please provide the permit number. Please provide the number of bedrooms that each residential lot will serve. Section VI.6 indicates that a flow reduction has been approved, however no approved flow reduction letter was submitted. Please submit the approved flow reduction letter. Erin Deck Department of Environmental Quality Division of Water Resources Raleigh Regional Office Office: 919-791-4258 •.: ""Nothing Compares y,v� Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Deck, Erin M From: Deck, Erin M Sent: Monday, March 4, 2019 9:10 AM To: 'Kevin Varnell' Cc: 'jamey.baines@townofnashvillenc.gov' Subject: RE: [External] Aviation Subdivision Good morning, I wanted to touch base regarding the subject fast track sewer extension permit. As soon as the permittee agrees to the changes, I can finish drafting the permit. Thank you. Erin Deck Department of Environmental Quality Division of Water Resources Raleigh Regional office Office: 919-791-4258 Nothing Compares Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Kevin Varnell[mailto:kvarnell@stocksengineering.com] Sent: Monday, February 18, 2019 3:47 PM To: Deck, Erin M <erin.deck@ncdenr.gov> Subject: FW: [External] Aviation Subdivision 'CAUTION: External email. Do not click links or open attachments unless you verify: Send all suspicious email as -an attachment to ,i`eavrt.s�a� � nc,�av Erin, See below from the City of Rocky Mount. I will forward the email from Jamey Baines as soon as I receive it. Sincerely, J. h Eviw VurK& irw ME ENGINEERING aw crosr WA!� +.nrcto+r SMCEI Pia RM Ma 1;aSITY_t[, si E_ 2MG PHa-JE (252) 459-MG ,Nw,v SrW.:Sch'QNErCr11C COW Our Competitive Advantage We build long term relationships with our clients by being Creative, Personable, Accessible, Responsive, and Knowledgeable. From: Donald Perry <donald.Perry@rockymountnc.gov> Sent: Monday, February 18, 2019 3:42 PM To: Kevin Varnell <kvarnell@stocksengineering.com> Cc:'jamey.baines@townofnashvillenc.gov' <Iamey,.baines@townofnashvillenc.gov>; Brad Kerr <brad. kerr@ rocky mountnc. ov>; Negrete Silver <negrete.silver@rockymountnc.gov> Subject: RE: [External] Aviation Subdivision Kevin, We acknowledge and accept the additional 1,800 GPD in flow. This brings this request to a total of 3,960 GPD in flow. Thanks, Donald M. Perry, PE, CPESC Assistant City Engineer —Water Resources City of Rocky Mount t: 252.972.1122 'Please note that email sent to and from this address is subject to North Carolina Public Records Laws and may be disclosed to third parties. From: Kevin Varnell <kvarnell@stocksenginee ring.com> Sent: Monday, February 18, 2019 2:10 PM To: Donald Perry <donald.perry@rockvmountnc.gov> Cc:'jamey.baines@townofnashvillenc.gov' <iame .baines townofnashvillenc. ov> Subject: FW: [External] Aviation Subdivision Donald / Jamey, We have had to revise the Sewer Permit for Aviation to show the lots that are connecting to the existing sewer. See the email chain below for more information. Therefore the total flow now is 3,960 GPD or 1,800 GPD more than the original permit. DEQ is good with correcting with the revised application without new signatures, so long as you both will send an email acknowledging the additional 1,800 GPD in flow. Would both of you mind replying back to this email with an acceptance of the flow? Sincerely, J. Ktv%w Varml.l. ENGINEERING Ltal CAST 1VASOiwGTOt; S-REC1 PC. aux 110 NASHV,LL£. N rr 2:856 1'h0`IE (252) &59-`s19& wrnY S� vCx5£ raq `iEEf+:ta� GUI Our Competitive Advantage We build long term relationships with our clients by being Creative, Personable, Accessible, Responsive, and Knowledgeable. From: Deck, Erin M <erin.deck@ncdenr.eov> Sent: Monday, February 18, 2019 1:47 PM To: Kevin Varnell <kvarnell stockseneineerine.com> Cc: Mike Stocks <mstocks@stocksen ineeringcom>;'jamey.baines@townofnashvillenc.gov' <iamey.baines townofnashvillenc.gov> Subject: RE: [External] Aviation Subdivision Good Afternoon, can use the revised pages as long as the permittee agrees to the changes. We will also need something from the City of Rocky Mount saying they will accept the additional proposed flow. Once those have been received, I can more forward drafting the permit. Thank you. Erin Deck Department of Environmental Quality Division of Water Resources Raleigh Regional Office Office: 919-791-4258 •, : -�Nothing Compares Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Kevin Varnell [mailto:kvarnell@stockseneineerine.coml Sent: Monday, February 18, 201911:40 AM To: Deck, Erin M <erin.deck@ncdenr.eov> Cc: Mike Stocks <mstocks@stocksensineerine.com>; 'jamey.baines@townofnashvillenc.gov' <jamey.baines@townofnashvillenc.gov> Subject: [External] Aviation Subdivision CAUTION: External email. Do not click'llnks or open attachments unless you,verify. Send all suspicious -email as an attachment to ort.spama- c:"oy.. ..d Erin, The Subdivision does consist of 11 lots total. However, Lots 1-5 are actually service taps off of an existing sewer line. I have no idea if any future development flow had been accounted for in a previous permit as this line has been installed for some time. Therefore, I would think that it needs to be added into this permit to account for the flow. All houses are proposed to be 3 bedroom or less. Therefore the total flow requested would be 360 GPD for 11 Lots = 3,960 GPD. Section V1.6 was inadvertently checked Yes and it should have been checked "No". We have revised the Word file for the permit and attached it. Can we simply replace the revised pages with the current permit you have? Let me know if you have any questions or concerns. Sincerely, I. lCBVEK, VAry AL RX & WE L" ENGINEERING W LA WAS-i"MrotJ SMEO P0 8ox 110a NASNv _LE. N C 27856 PHL?NF. (252.1 454-W96 •n•�rs SioC•;SEtsG'+IEEi�lNG Cau Our Competitive Advantage We build long term relationships with our clients by being Creative, Personable, Accessible, Responsive, and Knowledgeable. From: Deck, Erin M <erin.deck@ncdenr.gov> Sent: Monday, February 11, 2019 2:25 PM To: 'ame .baines townofnashvillenc. ov; Mike Stocks <mstocks stocksen ineerin .com> Cc: Robinson, Jason <iason.t.robinson@,ncdenr.gov> Subject: Aviation Subdivision Good afternoon, We are in the process of reviewing the subject application and require some information prior to drafting the permit. The narrative states that the subdivision consists for 11 residential lots; however the application is only for lots 6- 11. Has the flow associated with lots 1-5 been accounted for in a previous permit? If so, please provide the permit number. Please provide the number of bedrooms that each residential lot will serve. Section VI.6 indicates that a flow reduction has been approved, however no approved flow reduction letter was submitted. Please submit the approved flow reduction letter. Erin Deck Department of Environmental Quality Division of Water Resources Raleigh Regional Office Office: 919-791-4258 Ni.cr- -�-/'Nothing Compares -,-, Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Deck, Erin M From: Kevin Varnell <kvarnell@stocksengineering.com> Sent: Tuesday, March 26, 2019 8:24 AM To: Deck, Erin M Cc: 'jamey.baines@townofnashvillenc.gov' Subject: [External] Aviation Subdivision CAUTION: External email. Do not click links -or. open attachments unless yop:verify. Send all susplclous.email as an attachment to 1.J eport.S9am nc.gov Erin, I am so sorry. Jamey sent the original email and I assumed you were copied. I apologize and appreciate you following up. See below. Sincerely, J. Ktvtm VarK.ei.i. ENGINEERING b3i { A5r WAS l-IW .TOM STPEE1 P 6 BOX 19ASH'ILLE. N G 27856 PROSE (252) a59- ri7AVSPOCriWEtdGNEERIll.r. CGu Our Competitive Adyantaee We build long term relationships with our clients by being Creative, Personable, Accessible, Responsive, and Knowledgeable. From: jamey.baines <jamey.baines@townofnashvillenc.gov> Sent: Monday, March 4, 201910:17 AM To: Kevin Varnell <kvarnell@stocksengineering.com>; donald.perry@rockymountnc.gov Subject: Re: FW: [External] Aviation Subdivision Gentlemen, The Town of Nashville agrees to accept the additional 1800 GPD more than the original permit. Thanks! Jamey Baines Town of Nashville Public Works On February 18, 2019 at 2:09 PM Kevin Varnell <kvarnell(cDstocksengineering.com> wrote: Donald /Jamey, We have had to revise the Sewer Permit for Aviation to show the lots that are connecting to the existing sewer. See the email chain below for more information. Therefore the total flow now is 3,960 GPD or 1,800 GPD more than the original permit. DEQ is good with correcting with the revised application without new signatures, so long as you both will send an email acknowledging the additional 1,800 GPD in flow. Would both of you mind replying back to this email with an acceptance of the flow? Sincerely, J. FGevLw varKtLl, UT ENGINEERING 2,01 EAS; WASKNGTON STREET Po. PDX 7tUH NASH'. LLF. N r- 27856 VHI.�}iE- (252) +50-519Ei Our Competitive Advantage We build long term relationships with our clients by being Creative, Personable, Accessible, Responsive, and Knowledgeable. From: Deck, Erin M <erin.deck@ncdenr.gov> Sent: Monday, February 18, 2019 1:47 PM To: Kevin Varnell <kvarnell@stocksengineering.com> Cc: Mike Stocks <mstocks Pstocksengineerin .com>;'jamey.baines@townofnashvillenc.gov' <iamev.baines@townofnashvillenc.gov> Subject: RE: [External] Aviation Subdivision Good Afternoon, I can use the revised pages as long as the permittee agrees to the changes. We will also need something from the City of Rocky Mount saying they will accept the additional proposed flow. Once those have been received, I can more forward drafting the permit. Thank you. Erin Deck Department of Environmental Quality Division of Water Resources Raleigh Regional Office Office: 919-791-4258 f .1 M.- Nothing Compares, Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Kevin Varnell[mailto:kvarnellOstockseneineerine.com] Sent: Monday, February 18, 2019 11:40 AM To: Deck, Erin M <erin.deck@ncdenr.gov> Cc: Mike Stocks<mstocks_@stockseneineering.com>; 'jamey.baines@townofnashvillenc.gov' <iamey.baines@townofnashvillenc.eov> Subject: [External] Aviation Subdivision G4UTION: External email. Do not click links or open attachments unless you verify. SI*nd all suspicious email as an - attachment m.reno.scamrwc.ov Erin, The Subdivision does consist of 11 lots total. However, Lots 1-5 are actually service taps off of an existing sewer line. I have no idea if any future development flow had been accounted for in a previous permit as this line has been installed for some time. Therefore, I would think that it needs to be added into this permit to account for the flow. All houses are proposed to be 3 bedroom or less. Therefore the total flow requested would be 360 GPD for 11 Lots = 3,960 GPD. Section V1.6 was inadvertently checked Yes and it should have been checked "No". We have revised the Word file for the permit and attached it. Can we simply replace the revised pages with the current permit you have? Let me know if you have any questions or concerns. Sincerely, J. tccvi vm va nn.eL1. Imm MI. - ENGINEERING IDI EAST WASMNZ;TGN STREET g o, Rai NASHALE, N.C. 27836 PHONE (252) 451.i-5IB. 4V,W ST:R:hSENQ`iEERtN^.,CCU Our Competitive Advantage We build long term relationships with our clients by being Creative, Personable, Accessible, Responsive, and Knowledgeable. From: Deck, Erin M <erin.deck@ncdenr.gov_> Sent: Monday, February 11, 2019 2:25 PM To: iamey.baines@townofnashviilenc.g_ov: Mike Stocks <mstocks aPstocksengineering.com> Cc: Robinson, Jason <'aI son.t.robinson@ncdenr.gov> Subject: Aviation Subdivision Good afternoon, We are in the process of reviewing the subject application and require some information prior to drafting the permit. The narrative states that the subdivision consists for 11 residential lots; however the application is only for lots 6-11. Has the flow associated with lots 1-5 been accounted for in a previous permit? If so, please provide the permit number. Please provide the number of bedrooms that each residential lot will serve. Section VI.6 indicates that a flow reduction has been approved, however no approved flow reduction letter was submitted. Please submit the approved flow reduction letter. Erin Deck Department of Environmental Quality Division of Water Resources Raleigh Regional Office Office: 919-791-4258 Nothing Compares. t Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties.