Loading...
HomeMy WebLinkAboutNC0083551_Inspection_20190312 DocuSign Envelope ID:2F06550D-61BB-47E4-AF94-0603EC5D6ACF United States Environmental Protection Agency Form Approved. EPA Washington,D.C.20460 OMB No.2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding(i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN I 2 IF I 3 I NCO083551 111 12 I 19/03/12 I17 18 I S I 19 I G I 201 I 211111 I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I r6 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- 671 70Id I 71 I—n I 72 I n, I 73I I I 74 75I I I I I I I I80 I—I Section B: Facility Data I� I Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES oermit Number) 01:50PM 19/03/12 18/01/01 Dixon WTP 6661 Wilmington Hwy Exit Time/Date Permit Expiration Date Sneads Ferry NC 28460 02:15PM 19/03/12 22/11/30 Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data James R McDonnel//910-915-6937/ James Robert McDonnel/ORC/910-340-9213/ Name,Address of Responsible Official/Title/Phone and Fax Number Contacted Seth Adam Brown, /Water Superintendent/910-355-0267/ No Section C:Areas Evaluated During Inspection(Check only those areas evaluated) Permit 0 Flow Measurement Operations&Maintenance Records/Reports Self-Monitoring Program 0 Facility Site Review Compliance Schedules Effluent/Receiving Waters Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date Helen I Perez DocuSigned by: WIRO WQ//910-796-7387/ 3/20/2019 E 3969413E_ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date Morelia Sanchez-King WIRO WQ//910-796-7218/ DocuSigned by: 3/22/2019 EPA Form 3560-3(Rev 9-94)Previous editions are obsolete. E3ABA14Ac7Dc434... Page# 1 DocuSign Envelope ID:2F06550D-61BB-47E4-AF94-0603EC5D6ACF NPDES yr/mo/day Inspection Type (Cont.) 1 31 NCO083551 I11 121 19/03/12 117 18 ICI Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) A routine compliance inspection of the Dixon WTP was conducted on 03-12-2019. The purpose of the evaluation was to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES Permit NC0083551. The ORC, Jim McDonnel,was present during the inspection. This water treatment plant has a discharge of greensand filter, ion exchange backwash and reverse osmosis reject wastewater. An average of 0.347 MGD is discharged into an unnamed tributary to Stones Creek. Required documentation is well organized and complete. The three sedimentation lagoons are operated in series and are well maintained. The flowmeter was calibrated in October, 2018 by Carolina Water Services. Three monitoring wells are sampled and tested for a variety of parameters annually, but this is not a requirement stated in the current permit. Effluent toxicity test results submitted during the last permit cycle showed the potential for aquatic toxcity in the receiving stream. As a result, a Discharge Alternatives Evaluation is required, as part of the current permit, to be submitted with the next permit renewal application. Since the installation of the reverse osmosis system in 2017, the facility has not failed toxcity. The Dixon WTP is in compliance with the NPDES permit NC0083551. Please review the comment section of the inspection report for more details. Page# 2 DocuSign Envelope ID:2F06550D-61BB-47E4-AF94-0603EC5D6ACF Permit: NCO083551 Owner-Facility: Dixon WTP Inspection Date: 03/12/2019 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ 0 ❑ application? Is the facility as described in the permit? 0 ❑ ❑ ❑ #Are there any special conditions for the permit? 0 ❑ ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: A discharge alternatives evaluation is required with the next permit renewal application due to a history of failed toxicity tests. Standby Power Yes No NA NE Is automatically activated standby power available? 0 ❑ ❑ ❑ Is the generator tested by interrupting primary power source? 0 ❑ ❑ ❑ Is the generator tested under load? ❑ ❑ ❑ Was generator tested &operational during the inspection? ❑ 0 ❑ ❑ Do the generator(s)have adequate capacity to operate the entire wastewater site? ❑ ❑ ❑ Is there an emergency agreement with a fuel vendor for extended run on back-up power? ❑ ❑ ❑ Is the generator fuel level monitored? ❑ ❑ ❑ Comment: The wastewater treatment system is on the same generator as the water treatment system. It is automatically tested under load every Monday. Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters,for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: The facility appears to be well maintained. Lagoons Yes No NA NE Type of lagoons? Facultative #Number of lagoons in operation at time of visit? 3 Are lagoons operated in? Series #Is a re-circulation line present? ❑ ❑ 0 ❑ Is lagoon free of excessive floating materials? 0 ❑ ❑ ❑ #Are baffles between ponds or effluent baffles adjustable? ❑ 0 ❑ ❑ Are dike slopes clear of woody vegetation? 0 ❑ ❑ ❑ Are weeds controlled around the edge of the lagoon? 0 ❑ ❑ ❑ Page# 3 DocuSign Envelope ID:2F06550D-61BB-47E4-AF94-0603EC5D6ACF Permit: NCO083551 Owner-Facility: Dixon WTP Inspection Date: 03/12/2019 Inspection Type: Compliance Evaluation Lagoons Yes No NA NE Are dikes free of seepage? 0 ❑ ❑ ❑ Are dikes free of erosion? 0 ❑ ❑ ❑ Are dikes free of burrowing animals? 0 ❑ ❑ ❑ #Has the sludge blanket in the lagoon (s)been measured periodically in multiple ❑ ❑ ❑ locations? #If excessive algae is present, has barley straw been used to help control the growth? ❑ ❑ 0 ❑ Is the lagoon surface free of weeds? ❑ ❑ ❑ Is the lagoon free of short circuiting? ❑ ❑ ❑ Comment: Every 3 years, one pond is drained and a contract company is hired to clean out the accumulated solids. The last cleaning was in 2017. Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? 0 ❑ ❑ ❑ Are all other parameters(excluding field parameters)performed by a certified lab? 0 ❑ ❑ ❑ #Is the facility using a contract lab? M ❑ ❑ ❑ #Is proper temperature set for sample storage(kept at less than or equal to 6.0 degrees 0 ❑ ❑ ❑ Celsius)? Incubator(Fecal Coliform)set to 44.5 degrees Celsius+/-0.2 degrees? ❑ ❑ 0 ❑ Incubator(BOD)set to 20.0 degrees Celsius+/- 1.0 degrees? ❑ ❑ 0 ❑ Comment: Effluent parameters are performed by the ONWASA central lab (certification #539)or Envirochem. The quarterly toxicity monitoring is done by ETS. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ ❑ Is sample collected below all treatment units? 0 ❑ ❑ ❑ Is proper volume collected? ❑ ❑ ❑ Is the tubing clean? 0 ❑ ❑ ❑ #Is proper temperature set for sample storage(kept at less than or equal to 6.0 degrees 0 ❑ ❑ ❑ Celsius)? Is the facility sampling performed as required by the permit(frequency, sampling type 0 ❑ ❑ ❑ representative)? Comment: Sampler temperature during inspection was 3 degrees Celsius. Compliance Schedules Yes No NA NE Is there a compliance schedule for this facility? ❑ 0 ❑ ❑ Page# 4 DocuSign Envelope ID:2F06550D-61BB-47E4-AF94-0603EC5D6ACF Permit: NCO083551 Owner-Facility: Dixon WTP Inspection Date: 03/12/2019 Inspection Type: Compliance Evaluation Compliance Schedules Yes No NA NE Is the facility compliant with the permit and conditions for the review period? ❑ 0 ❑ ❑ Comment: Since the last inspection in 2014, there have been four monitoring violations; a daily and monthly TSS violation in 4/2016, a daily PH violation in 10/2015 and failed toxicity in 7/2016 and 1/2017. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? 0 ❑ ❑ ❑ Is all required information readily available, complete and current? 0 ❑ ❑ ❑ Are all records maintained for 3 years(lab. reg. required 5 years)? 0 ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? 0 ❑ ❑ ❑ Is the chain-of-custody complete? 0 ❑ ❑ ❑ Dates,times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ❑ (If the facility is=or>5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ ❑ on each shift? Is the ORC visitation log available and current? ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ❑ ❑ ❑ Comment: Records were organized and complete. Page# 5 DocuSign Envelope ID:2F06550D-61BB-47E4-AF94-0603EC5D6ACF ROY COOPED C:�Crry�r MICHAEL S.R.EGAN .� . Seer'etQry LINDA CULPEPPER NORTH CAROLINA arrm r Environmental Quallry March 20, 2019 Mr. Jeffery Hudson, Executive Director Onslow Water and Sewer Authority 228 Georgetown Road Jacksonville, NC 28540 SUBJECT: Compliance Inspection Report Dixon WTP NPDES WW Permit No. NCO083551 Onslow County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Dixon WTP on 3/12/2019. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0083551. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. North Carol"DepsrtmentofEnvironmeatedQua;ity I DWsiorof Water Resources 1i'drnington Regional Office 1 127 Cardinai DFive Extension 11451m:ngton, North Caroma 25405 910-796-7215 DocuSign Envelope ID:2F06550D-61BB-47E4-AF94-0603EC5D6ACF If you should have any questions, please do not hesitate to contact Helen Perez with the Water Quality Regional Operations Section in the Wilmington Regional Office at 910-796-7215 or via email at helen.perez@ncdenr.gov. Sincerely, DocuSigned by: E3ABA14AC7DC434... Morella Sanchez-King, Regional Supervisor Water Quality Regional Operations Section Wilmington Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Cc: Uploaded to Laserfiche Jim McDonnel — electronic copy NorthCaroTinaDepsrtrrentofEnvironmentadQuaky I 6;v:sonof Water Resources Z��p Wilmington Reg•3ra:DfrD- 1 127 CardinalDriveExtens-3n I Wilrn,ngton. North Caro:ma73405 �•"'•i e• ' 910-796-7215