Loading...
HomeMy WebLinkAbout100036_Structual Evaluation_20180807 40 Division of Water Resources Facility Number - O Division of Soil and Water Conservation \ O Other Agency. Type of Visit: O Compliance Inspection 0 Operation Review 0 Structure Eva tion O Technical Assistance Reason for Visit: O Routine O Complaint O Follow-up O Referral O mergency O Other O Denied Access Date of Visit: Arrival Time: ) p tE S Departure Time: ( // County: Region: Farm Name: Owner Email: Owner Name: Phone: Mailing Address: Physical Address: Facility Contact: / Title: Phone: l C Onsite Representative: -/� r- 1: A/r Integrator: Certified Operator: Certification Number: Back-up Operator: Certification Number: Location of Farm: Latitude: Longitude: Design Current Design Current Design Current Swine Capacity Pop. Wet Poultry Capacity Pop. Cattle Capacity Pop. Wean to Finish Layer Dairy Cow Wean to Feeder I INon-Layer I I Dairy Calf Feeder to Finish Dairy Heifer Farrow to Wean Design Current Dry Cow Farrow to Feeder Dry Poultry Capacitv Pop. Non-Dairy Farrow to Finish ILayers I Beef Stocker Gilts Non-Layers Beef Feeder Boars Pullets Beef Brood Cow Turkeys Other Turkey Poults Othcr Other Discharges and Stream Impacts 1. Is any discharge observed from any part of the operation? ❑ Yes Io ❑ NA ❑ NE Discharge originated at: ❑ Structure ❑ Application Field ❑ Other: a. Was the conveyance man-made? ❑ Yes ❑ No ❑ NA ❑ NE b. Did the discharge reach waters of the State?(If yes,notify DWR) ❑ Yes ❑ No ❑ NA ❑ NE c. What is the estimated volume that reached waters of the State(gallons)? d. Does the discharge bypass the waste management system?(If yes,notify DWR) ❑ Yes ❑ No ❑ NA ❑ NE 2.Is there evidence of a past discharge from any part of the operation? ❑ Yes ONo ❑ NA ❑ NE 3.Were there any observable adverse impacts or potential adverse impacts to the waters ❑ Yes No ❑ NA ❑ NE of the State other than from a discharge? Page I of 21412015 Continued Facili Number: IQ - Date of Inspection: / Waste Coliection&Treatment 4. Is storage capacity(structural plus storm storage plus heavy rainfall)less than adequate? E5Yes [:] No ❑ NA ❑ NE a. If yes,is waste level into the structural freeboard? ❑ems ❑ No ❑ NA ❑ NE Structure 1 Structure 2 / Structure 3 Structure 4 Structure 5 Structure 6 Identifier: Spillway?: Designed Freeboard(in): Observed Freeboard(in): 5.Are there any immediate threats to the integrity of any of the structures observed? ❑ Yes No ❑ NA ❑ NE (i.e.,large trees,severe erosion,seepage,etc.) 6.Are there structures on-site which are not properly addressed and/or managed through a ❑ Yes No ❑ NA ❑ NE waste management or closure plan? If any of questions 4-6 were answered yes,and the situation poses an immediate public health or environmental threat,notify DWR 7.Do any of the structures need maintenance or improvement? ❑ Yes ❑ No ❑ NA E!f—NE 8.Do any of the structures lack adequate markers as required by the permit? ❑ Yes ❑ No ❑ NA [fNE (not applicable to roofed pits,dry stacks,and/or wet stacks) 9.Does any part of the waste management system other than the waste structures require ❑ Yes ❑ No ❑ NA EQ maintenance or improvement? Waste Anolication 10.Are there any required buffers,setbacks,or compliance alternatives that need ❑ Yes ❑ No ❑ NA E NE maintenance or improvement? 11. Is there evidence of incorrect land application?If yes,check the appropriate box below. ❑ Yes ❑ No ❑ NA E]NE ❑ Excessive Ponding ❑ Hydraulic Overload ❑ Frozen Ground ❑ Heavy Metals(Cu,Zn,etc.) ❑ PAN ❑ PAN> 10%or 10 lbs. ❑ Total Phosphorus ❑ Failure to Incorporate Manure/Sludge into Bare Soil ❑ Outside of Acceptable Crop Window ❑ Evidence of Wind Drift ❑ Application Outside of Approved Area 12.Crop Type(s): 13. Soil Type(s): 14.Do the receiving crops differ from those designated in the CAWMP? ❑ Yes ❑ No ❑ NA R]NE 15.Does the receiving crop and/or land application site need improvement? ❑ Yes ❑ No ❑ NA ff NNE 16.Did the facility fail to secure and/or operate per the irrigation design or wettable ❑ Yes ❑ No ❑ NA NE acres determination? 17.Does the facility lack adequate acreage for land application? ❑ Yes ❑ No ❑ NA U NE 18. Is there a lack of properly operating waste application equipment? ❑ Yes ❑ No ❑ NA Reauired Records&Documents 19.Did the facility fail to have the Certificate of Coverage&Permit readily available? ❑ Yes ❑ No ❑ NA ❑.DIE 20. Does the facility fail to have all components of the CAWMP readily available?If yes,check ❑ Yes ❑ No ❑ NA B-NE the appropriate box. ❑WUP ❑Checklists ❑Design ❑Maps ❑ Lease Agreements ❑Other: 21. Does record keeping need improvement?If yes,check the appropriate box below. [:] Yes ❑ No ❑ NA 2rNE ❑Waste Application ❑Weekly Freeboard ❑Waste Analysis ❑Soil Analysis ❑Waste Transfers ❑Weather Code ❑Rainfall ❑Stocking ❑Crop Yield ❑120 Minute Inspections ❑Monthly and V Rainfall Inspections ❑Sludge Survey 22.Did the facility fail to install and maintain a rain gauge? ❑ Yes ❑ No ❑ NA [3Z 23.If selected,did the facility fail to install and maintain rainbreakers on irrigation equipment? ❑ Yes [:] No ❑ NA �i Page 2 of 3 21412015 Continued [Facility Number: 10 - 206 Date of Inspection: 24.Did the facility fail to calibrate waste application equipment as required by the permit? ❑ Yes ❑ No ❑ NA 25.Is the facility out of compliance with permit conditions related to sludge? If yes,check ❑ Yes ❑ No ❑ NA PNE the appropriate box(es)below. ❑Failure to complete annual sludge survey ❑Failure to develop a POA for sludge levels ❑Non-compliant sludge levels in any lagoon List structure(s)and date of first survey indicating non-compliance: 26. Did the facility fail provide documentation of an actively certified operator in charge? ❑ Yes ❑ No ❑ NAJ "'E 27. Did the facility fail to secure a phosphorus loss assessments(PLAT)certification? ❑ Yes ❑ No e-N-A ❑ NE Other Issues 28.Did the facility fail to properly dispose of dead animals with 24 hours and/or document ❑ Yes ❑ No ❑ NA ETNE and report mortality rates that were higher than normal? 29.At the time of the inspection did the facility pose an odor or air quality concern? ❑ Yes L_I No ❑ NA ❑ NE If yes,contact a regional Air Quality representative immediately. 30. Did the facility fail to notify the Regional Office of emergency situations as required by the ❑ Yes ENo ❑ NA ❑ NE permit?(i.e.,discharge,freeboard problems,over-application) 31.Do subsurface tile drains exist at the facility?If yes,check the appropriate box below. ❑ Yes ❑ No ❑ NA [3 i4 ❑ Application Field ❑ Lagoon/Storage Pond ❑ Other: 32. Were any additional problems noted which cause non-compliance of the permit or CAWMP? ❑ Yes ]fNo ❑ NA ❑ NE 33.Did the Reviewer/inspector fail to discuss review/inspection with an on-site representative? ❑ Yes EfNo ❑ NA ❑ NE 34.Does the facility require a follow-up visit by the same agency? ❑ Yes J o ❑ NA ❑ NE Comments(refer to question#): Explain any YES answers and/or any additional recommendations or any other comments. Use drawings of facility to better explain situations(use additipttpi & es as necessary). 01 _A VGV C O7CC l! 1 oAo - e He( /S`✓,e4c2 /C vim. On5/ C �� � � f(i-� �G1�o�sL StLII �1CIAC"'PI/ng1u ,d �lGt // � , puusl� u �l���,�,Pld ,dl �;�-, s G-d It t�s,ll, ( an+ �•u •.� raJ� Reviewer/Inspector Name: 04L r Q t7 u1tEL( a SArLWG rs*hone: Reviewer/Inspector Signature: ✓ Date: Page 3 of 3 21412015