Loading...
HomeMy WebLinkAboutStout Landing Subdivision - 1283-Runoff coefficient calcs1283 Stout Landing Pond 1 Storm Water Control SCS curve number Hydraulic Soil Group :A Area SCS CN Lots (sf) 864,000 98 Pavement (sf) 368,562 98 Open space (sf) 1,570,111 49 Offsite -open space (sf) 402,428 39 Offsite -impervious (sf) 0 98 Total (sf)3205101 67 Total (ac)73.58 Rational Coefficient Predevelopment Postdevelopment Area C Area C Impervious (sf) 0 0.95 Building (sf) 864,000 0.95 Open space (sf) 3,205,101 0.30 Pavement (sf) 368,562 0.95 Open space (sf) 1,570,111 0.30 Offsite -open space (sf) 402,428 0.30 Offsite -impervious (sf) 0 0.95 Total (ac)3205101 0.30 Total (ac)3205101 0.59 Total (ac)73.58 Total (ac)73.58 1283-Runoff coefficient calcs.xls Printed 3/19/2019