Loading...
HomeMy WebLinkAboutNCS000350_HISTORICAL WITH APPLICATION_20170503-µ__ STORMWATER-DIVISION-CODING-SHEET-__ PERMIT NO. N (s 0003 Sb DOC TYPE ❑ FINAL PERMIT ❑ MONITORING INFO ,�' APPLICATION ❑ COMPLIANCE ❑ OTHER DOC DATE ❑ �n, ( �QSQ3 YYYYM M D D NC Dept Ofrnvironmental Quality MAY - 2017 Raleigh Regional Office May 3, 2017 Mr. Thaddeus Valentine N.C. Department of Environmental Quality Energy Mineral and Land Resources, Land Quality Section, Raleigh Regional Office 1628 Mail Service Center Raleigh, NC 27699-1628 Subject: 2016 Annual Summary DMR for NPDES Permit #: NCS000350 (Stormwater) Dear Mr. Valentine: Edgecombe Genco, LLC (NPDES Permit #: NCS000350) 2016 Annual Summary Discharge Monitoring Report (DMR) for Stormwater was received by the N.C. Department of Environmental Quality on February 16, 2017. Recently it was discovered that a copy of the report was not submitted to the Raleigh Regional Office. Enclosed please find a copy of the 2016 Annual Summary DMR for Stormwater. Should you have any questions or concerns, please contact me at 252-442-0708 ext. 407. Regards, David Herring, Compliance'anager Edgecombe Genco, LLC Email: David.Herring@naes.com Cc: Environmental Files e .. STORMWATER DISCHARGE OUTFALL (SDO) ANNUAL SUMMARY DATA MONITORING REPORT (DMR)1 SPPP Annual Update DATA REVIEW FORM Calendar Year 2016 individual NPDES Permit No. NCSoo0350 or Certificate of Coverage (COC) No. NCG❑❑❑❑❑❑ This monitoring report summary of the calendar year should be kepi on file on -site with the facility SPPP. Facility Name: Ed ecombe Genco LLC County: Edgecombe Phone Number: 252 442-0708 Total no, of SDOs monitored 1 Outfall No. SD0#1 Is this outfall currently in Tier 2 (monitored monthly)? Yes ❑ No Was this outfall ever in Tier 2 (monitored monthly) during the past year? Yes ❑ No If this outfall was in Tier 2 last year, why was monthly monitoring discontinued? Received approval from DWQ to reduce monitoring frequency ❑ Other ❑ Was this SDO monitored because of vehicle maintenance activities? Yes ❑ No Parameter, (units) Total Pb,Sb,Se,T1,Zn, Rainfall,KAg,As,l3e,Cd, -SulfatePH-_-inchesu,H9,Ni AI,B,COD,TSS Benchmark N/A Date SamplehF, irk' ;-i. r -4 . :,i`y.-. .-:-?..✓-. +-".f.T `teV '�s. - ••T. -,,l -.}• ar." �.. P*t.. { }� rt I ,c,��v .(- .-. �,- �4r [1 r YW ..F .'' <. N' x ✓ Collected, •'i r a _ mmldd/yy. t..4 Analytical Analytical Analytical 9/312016 Results Results Results Attached Attached Attached Analytical 9/22/2016 Results Attached ,- SWU-264 - Generin. Annual DMR [ L(Ysed 5/17/2013 i r I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Signature Date Z -Iq-17 For questions, contact your local Regional Office: QWD Regional Office Contact Information: ASHEVILLE REGIONAL OFFICE (828) 296-4500 RALEIGH REGIONAL. OFFICE 3800 Barrett Drive Raleigh, NC 27609 (919) 791-4200 WINSTON-SALENI REGIONAL OFFICE 585 Waughtovoi Street Winston-Salem, NC 27107 (336) 771-5000 -- --- .� � m FAYETTEVILLE REGIONAL OFFICE Systel-Building-Suite 7L4 Fayetteville, NC 28301-5043 WASHINGTON REGIONAL OFFICE 943 Washington Square Mall Washington, NC 27889 !! (252) 946-6481_ .CENTRAL OFFICE 1617 Mail Service Center Raleigh, NC 27699-1617 ! MOORESVILLE REGIONAL OFFICE (704) 663-1699 WILMINGTON REGIONAL OFFICE 127 Cardinal Drive Extension Wilmington, NC 28405-2845 (910) 796-7215 'roPraserve.Proved- i ar"denhalice �� P;orir� Ga:o±frta�s��valer:.." SWU-264 - Generin Annual DMR L� {ised 5/17/2013 Edgecombe Gertco LLC - Storm Water Permit # NCS000360 2016 Sample Type Grab (G) Composite (C) EPS Rain Gauge G G G G G G G G G G G G G G G G G G G G Unit of Measure Inches NA NA mg1L mg/L mg/L mg/L mg/L mglL ug/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg1L mg/L mg/L mg/L Units Threshold Value NA NA NA 0.75 0.36 0.07 0.001 1.00 0.007 NA 0.26 0.03 0.05 10-066 NA 0.067 0.75 NA 120 100 500 30 6-9 I Sample Period Total inches from Rain Event Sed.Pond Spillway Overflow Sample YIN Qualitative Samples pulled YIN Ag As Be Cd Cr Cu Hg NI Pb Sb Se TI Zn Al B COD TSS Sulfate O&G pH Jan., NIA NIA NIA NS NS NS NS NS NS NS NS NS NS NS N5 NS NS NS NS N5 NS NS NS Feb. NIA NIA NIA NS NS NS NS NS NS NS NS NS N5 N5 NS NS NS NS NS NS NS NS NS Mar. Apr 3:80 0:056 O.fit N5 May June 12 O.Q01: <0005` .<0 005�0 0Q 8 005 NS OD5 < fl f±IS �N$ <Q.O,E <0,01, NS 5 a.05 425.0, 10.$0 16_. 0 6:67 ff KAMM NS NB 5 >+aNS July Y Y 00,10 Q.7 .QU_01k Aug Set 913116 f f�NS NS INS NS NS NS N5 NS Oct 5 NSAINNSIM AtNSiffii__SIIL iiin-APB. mild.���_..��__.�r®__��__�rr���._o,w��:n���.�.�._�.�_�®W��� Nov. ,NS NS NS DNS N9 �NfdS NSN NS NS N5 NSa NSA NS N3 NS NS Dec. j9QJjVKN7M 135;� NSA Ns' x NSA NS NSa N 5 NS NS tYS NS N3 tVS NS NS DNS _ DNS NS S 5� Year 6 period 1 .. NOTE: 9/3/16 - The O&G sample bottle was brokenlcracked. 9122/16 - Another O&G sample was collected. pier 7 perr d 1 F NS-No Sample NA -Not Applicable Alexander, Laura a�lg�lb� From: Boswell, Angela <Angela.Boswell@naes.com> Sent: Wednesday, February 17, 2016 3:35 PM To: Georgoulias, Bethany; Romanski, Autumn Cc: Herring, David; Alexander, Laura Subject: RE: NCS000350 - Stormwater Permit Delegation of Signatory Authority Fallow Up Flag: Flag Status: Follow up Flagged Thanks Bethany ... Yes - This does help... Since we recently implemented eDMR and updated our Wastewater info, we just want to make sure our Stormwater info is up-to-date as well... Name/Ownership/Owner Contact has not changed; Laura - Could you please update our info to indicate the below: Facility Contact Person -- David Herring, Compliance Manager, no change in address or phone #, email: David. Herring@naes.com Permit Contact Person — Slate Thompson, Plant Manager, 6358 Old Battleboro Rd, Battleboro, NC 27809, no change phone #, email: Slate.Thompson@naes.com > Permit Billing Contact — David Herring, Compliance Manager, P.O. Box 370, Battleboro, NC 27809, no change phone #, email: David.Herring@naes.com Thanks for everyone's help to get our Stormwater info updated... -AngeCa. Bosweff Compliance Technician at Edgecombe Genco, LLC with NAES Corporation Address: PO Box 370 (Bill to): 6358 Old Battleboro Rd (Ship to), Battleboro, NC 27809 Office Phone: 252-442-0708 (Ext 406): Fax: 252-442-0990, email: Angela. Boswell(@,naes.com From: Georgoulias, Bethany[mailto:bethany.geornoulias@ncdenr.Qov] Sent: Wednesday, February 17, 2016 2:27 PM To: Romanski, Autumn; Boswell, Angela Cc: Herring, David; Alexander, Laura Subject: RE: NCS000350 - Stormwater Permit Delegation of Signatory Authority Ms. Boswell, We don't have a form similar to what you may be used to using for wastewater permits for delegated signature authority. As long as documents are signed by individuals according to the signatory requirements in the Standard Conditions of the permit, you should be fine. We do like to make sure Owner Affiliation information for the permit is up to date, though. Attached is what we have on file. Is the Owner Affiliation and other info. accurate? lTo make changes to Owner Affiliation, there is a form we need signed and returned (that's also attached). If there has been a Name/Ownership Change for the company, a different form is needed. Please let me know if that's the case. Any other changes (Permit, Facility, Owner Contacts) can be emailed to us — Laura Alexander can take care of those updates for you. I hope that helps! From: Georgoulias, Bethany [mailto:bethanv4eorgoulias@ncdenr.gov] Sent: Thursday, February 18, 2016 11:08 AM To: Boswell, Angela; Romanski, Autumn Cc: Herring, David; Alexander, Laura Subject: RE: NCS000350 - Stormwater Permit Delegation of Signatory Authority That's fine to wait until he comes back. Thanks so much! Bethany Bethany Georgoulias Environmental Engineer Stormwater Permitting Program, Division of Energy, Mineral, and Land Resources N.C. Department of Environmental Quality 919 807 6372 office bethany.georgoulias@ncdenr.gov 1612 Mail Service Center, Raleigh, NC 27699-1612 (mailing) 512 N. Salisbury Street, Raleigh, NC 27604 (location) Website: http://portal.ncdenr.org/web/lr/stonnwater Not hing C; am',pare$.00%,� i Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Boswell, Angela [mailto:Angela.Boswell@nae_s.coml Sent: Thursday, February 18, 2016 10:52 AM To: Georgoulias, Bethany<bethany.Reorgoulias@ncdenr.Rov>; Romanski, Autumn <Autumn.Roma nski@ncdenr.gov> Cc: Herring, David <David.Herrine@naes.com>; Alexander, Laura <laura.alexander@ncdenr.eov> Subject: RE: NC5000350 - Stormwater Permit Delegation of Signatory Authority Thanks Bethany... ➢ Stormwater "eDMR" — I hope it will be as user friendly as I've found the wastewater eDMR to be O; Stormwater outfalls & latitude/longitude coordinates — Sure.... David Herring is the best person to supply this info, but he is not available today & may not be available until sometime next week. Will next week be an acceptable timeframe to get this info to you? Thoughts? Thanks... Angela. BoSWett; Compliance Technician at Edgecombe Genco, LLC with NAES Corporation Address: PO Box 370 (Bill to); 6358 Old Battleboro Rd (Ship to), Battleboro, NC 27809 Office Phone: 252-442-0708 (Ext 406), Fax: 252-442-0990; email: Angela.BoswelI@naes.com From: Georgoulias, Bethany fmaiIto: bethanyaeorgoulias@ncdenr.govl Sent: Thursday, February 18, 2016 9:33 AM To: Boswell, Angela; Romanski, Autumn Cc: Herring, David; Alexander, Laura Subject: RE: NCS000350 - Stormwater Permit Delegation of Signatory Authority Ms. Boswell, I'm glad you mentioned you are implementing eDMR — we here in the Stormwater Program are working to implement same system to receive stormwater DMR data electronically. In preparation for that, could you send us a list of each of your Stormwater outfalls (the labels you use for them, such as '001') and latitude/longitude coordinates for those? That would be very helpful! Currently we only require permittees to keep outfall locations in their SPPP records and don't transfer the info. from DMRs submitted. This would give us a great head start on your permit. Thanks so much! Bethany Bethany Georgoulias Environmental Engineer Stormwater Permitting Program, Division of Energy, Mineral, and Land Resources N.C. Department of Environmental Quality 919 807 6372 office bethany. georgoul ias[7a,ncdenr. itov 1612 Mail Service Center, Raleigh, NC 27699-1612 (mailing) 512 N. Salisbury Street, Raleigh, NC 27604 (location) Website: http://i)ortal.nedenr,org/web/ir/stormwater Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Michael F. Easley, Governor William G. Ross, Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality 30 March 2007 CERTIFIED MAIL RETURN RECEIPT REQUESTED 7006-0810-0002-6048-1528 Mr. Richard Frymyer, General Manager Cogentrix of Rocky Mount P.O. Box 370, 6358 Old Battleboro Road Battleboro, NC 27809 Subject: Compliance Evaluation Inspections for NPDES Permits NCO077437 (wastewater) and NCS000350 (stormwater) and Resulting Notice of Violation, ' NOV-2007-PC-0151 Cogentrix of Rocky Mount, Battleboro Plant Edgecombe County Dear Mr. Frymyer: On 8 March 2007, Ronald Boone, of the Division of Water Quality's (DWQ) Raleigh Regional Office (RRO), conducted Compliance Evaluation Inspections (CEI) for the subject NPDES permits at the subject site. Your assistance and cooperation, as well as that of Mr. David Herring, Compliance Coordinator, were helpful and appreciated. Inspection reports are attached for your records and inspection findings are listed below. SITE DESCRIPTION 1. This is a coal-fired power generation facility. Wastewater generated. at the site is treated in one of two sedimentation/neutralization basins. The effluent is then pumped into a forced main that discharges into receiving waters known as the Tar River, this segment of which is classified as a Class C, nutrient sensitive water (NSW) in the Tar Pamlico river basin. The actual discharge point is located approximately four miles from the plant, in the river on the southwest corner of NC Hwy 97 and Springfield Road. 2. All site stormwater flows into a detention pond and is then discharged via one stormwater discharge outfall (SDO) located on the southern end of the site. The stormwater is discharged to receiving waters known as an unnamed tributary to Beech Branch, a Class C, nutrient sensitive water (NSW) in the Tar Pamlico river basin. Please note that the receiving stream currently listed on the Certificate of Coverage (COC) is Beech Creek. This is incorrect and should be corrected now, during the ongoing permit renewal cycle. The appropriate office of DWQ will be sent a copy of this letter to make them aware of the needed change. The actual receiving stream should be an unnamed tributary to Beech Branch. INSPECTION SUMMARY —Wastewater (NC0077437) Nne C Caro ina Natumlyk North Carolina Division of Water Quality Raleigh Regional Office Surface Water Protection Phone (919) 791-4200 Customer Service lntemet: h2o.enr.state.nc.us 1628 Mail Service Center Raleigh, NC 27699-1628 FAX (919) 571-4718 1-977-623-6748 An Equal Opportunity/Affirmative Action Employer— 50% Recycledl10% Post Consumer Paper Cogentrix of Rocky Mount, NCO077437 NCS000350, Compliance Evaluation Inspections 03/30/2007, Page 2V3 1'4 3. There were no problems noted with the wastewater treatment facility. The sedimentation basins, chemical injection systems, effluent pump station and flow measurement systems were all operational and as described in the permit. All equipment seemed well maintained and in good condition. 4. Effluent sampling is being accomplished as required in the permit. Comparison of discharge monitoring reports (DMR) with official lab data turned up no discrepancies and all parameters are being monitored as required. Field lab test data and procedures were examined and no problems were noted. 5. Outfall 003 and the effluent were observed and no problems were detected. The right-of-way (ROW) to the outfall was sufficiently maintained to allow access when needed. + 6. It was noted that discharges from the cooling tower blowdown (outfall 002) have become less frequent'since the new total residual chlorine (TRC) limit became effective back on 1 January 2007 and that you have not installed any systems to dechlorinate the water in order to meet the limit. Mr. Herring stated that you are blowing down into outfall 002 less frequently, in part because of the difficulty in meeting this limit. You may want to consider installing a dechlorination system to ensure you can meet the TRC limit when the time comes. It was noted that you do use gas chlorine at times to shock the system, along with Sodium Bromide regularly in the cooling tower system to control growth. INSPECTION SUMMARY — Stormwater NCS000350 7. The stormwater pollution prevention plan was inspected. All required components were present and met the minimum requirements. 8. The entire site was clean and well maintained. No obvious pollutant sources of concern were noted. 9. Qualitative monitoring is being performed more often than necessary. Please take note however that even though it is being performed more often than necessary, it still must be performed during the time periods specified in the permit, i.e. once during the spring (2nd quarter, Apr -Jun) and once during the fall (Sep -Nov). 10. Analytical monitoring is not being performed as required. According to Mr. Rick Neff, Cogentrix's engineer that designed the wet Stormwater detention pond, the pond is designed to meet the criteria specified in footnote #2, for table #1 (Analytical Monitoring Requirements), in Part II, Section B of the permit. According to this footnote, "If the detention pond discharges only in response to a storm event exceeding a ten year design storm, then no analytical monitoring is required and only qualitative monitoring shall be performed". This pond was actually discharging during the inspection, through an orifice placed in the side of the overflow standpipe, approximately 12" to 24" below the overflow level of the standpipe. This pond does not meet the intention of the above -mentioned footnote. In order to qualify for this exception, the pond would need to be designed not to discharge except for a storm event exceeding the 10-year design storm. In other words, in order to meet the intent of the footnote, the pond would never be allowed to discharge except in response to a storm event greater than the 10-year design storm. As it is currently designed, the wet stormwater detention pond at your site is not the correct unit for this application. Therefore, Cogentrix must immediately begin sampling the pond effluent in accordance with the analytical monitoring requirements found in the permit. Cogentfix of Rocky Mount, NCO077437 NCS000350, Compliance Evaluation Inspections 03/30/2007, Page 3 of 3 11. Additionally, the combined facts that it was not raining at the time of the inspection, it hadn't rained for quite some time prior to the inspection and yet the pond was still discharging during the inspection, strongly indicates that the pond must also be receiving flow from other unidentified sources. This may constitute one or more unidentified, unauthorized, illicit wastewater discharges. Cogentrix must immediately undertake to identify and halt all sources of wastewater, aside from site stormwater runoff, from draining into the pond and making it discharge during dry periods. Once identified, such discharges will have to be appropriately permitted. Please be aware that the issues mentioned in paragraph 10 above, constitute violations of your stormwater discharge permit. Such noncompliance is unacceptable and these violations may result in the assessment of civil penalties in an amount of up to $25,000 per day per violation. Please reply to this office within 30 days of your receipt of this letter, with a detailed corrective action plan, including an implementation schedule, leading to full and continuous compliance with your stormwater permit. Additionally, please specify your plan to - identify and correct all illicit discharges into your stormwater system. If you or your staff has any questions regarding the inspection or this letter, please contact Ron Boone for assistance at 919-791-4200. Sincerely, Charles Wakild, P.E. Surface Water Protection Supervisor Raleigh Regional Office Attachments: 1. Final Inspection Checklist cc Stormwater Permitting Unit Non -Point Source Compliance Enforcement Unit Central Files RRO/SWQ Files United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No, 2040-0057 Water Compliance Inspection Report Approval expires B-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 INS 2 51 31 NCS000350 111 121 07/03/08 117 IJ U 181rl 191cl 20I t LJ LJ LJ Remarks 211 1 1 1 1 1 1 1 1- 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 11 1 1_I I _l I LI IJ 11 I I,_16 ,1 Inspection Work Days Facility Self -Monitoring Evaluatlon Rating 211 QA --------- ------ ---------- -- Reserved -------------------- 67I 169 70I u I 71Lj 72U u 73� 74 751 1 ] I I 1 11 80 Section B: Facilit Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 10:00 AM 07/03/08 02/05/01 Edgecombe Genco, LLC-Battleboro ExitTime/Date Permit Expiration Date 63s8 old Battleboro Rd Battleboro NC 27809 12:00 PM 07/03/08 07/04/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible OfficiaVTitle/Phone and Fax Number Contacted Seth Carter,PO Box 370 Battleboro NC 27809//252-442-0805/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Storm Water Section D: Summary of Finding/Comment s Attach additional sheets of narrative and checklists as necessary) 4 , (See attachment summary) Name(s) and Signature(s) of inspector(s) Agency/Office/Phone and Fax Numbers Date Ron Boon RRO WQ//919-791-4200/ 30-- OC9 — 21— Signature of Man enZQA vie r Agency/Office/Phone and Fax Numbers Date gg �� t1 ?O 2,r7-V J EPA Form 3560-3 (Rev 9-9 revious editions are obsolete. Page # 1 NPDES yrlmo/day inspection Type (cont. 1 3I NC5000350 111 121 07/03/08 I17 18u Section D. Summary of Finding/Comments (Attach additionalsheetsof narrative and checklists as necessary) SP3 has been developed and implemented. Qualitative monitoring being done more often than required. However, permittee must ensure that even though its being done more often than needed, it still must be done at least twice per during the timeframes specified in the permit, i.e. spring - Apr through June and fall - Sep through Nov. Also, permittee is not conducting analytical monitoring because they have.a SW detention pond that they assert meets the criteria, of footnote #2 of table #1, Analytical Monitoring Requirements, in Part II, Section B of the permit, i.e. the stormwater "...detention pond discharges only in response to a storm event exceeding a ten yar design storm...", However, the pond was discharging at the time of the inspection through an orifice in the side of the overflow pipe that was placed approximately 12" to 24" below the overflow level of the overflow pipe. According to Cogehtrix personnel and their engineer, the orifice is the mechanism by which the level of the pond is kept at the level required for the pond to contain the 10-year design storm without overflowing at the overflow pipe. This is still considered a discharge that must be monitored in accordance with table #1. Finally, the above mentioned pond was discharging during the inspection despite that fact that it was not raining and hadn't rained for quite some time prior to the inspection. This strongly indicates one or more unidentified, unauthorized; illicit wastewater discharges through the SW detention pond. The permittee must immediately undertake to identify all discharges into the pond and stop them and/or have them appropriately permitted. Page # 2 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 - OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yrlmolday Inspection Type Inspector Fac Type 1 INI 2 ICI 31 N00077437 111 121 07/03/08 117 181rl 191cl 201 LJ U 1 LJ IJ IJ Remarks 211 1 1 1 1 1 1 1 Ll I I I I II11 1 1 1 1 1 1 1,I 1 1 I 1 1- 1 1 1 I,1 11 1 I 1 111 J—Lj6E _I Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 CIA -------------------------Reserved--------------------- 671 1 69 70 U 71 j) 72 ) N 73 J J) 74 751 11 I 1 1 I 1 80 �••� 1�� Section B: Facility Data Name and Location of Facility Inspected (Far Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 10:00 AM 07/03/08 05/07/01 . Battleboro plant Exit Time/Date Permit Expiration Date 6358 Old Battleboro Rd Battleboro NC 27805 12:00 PM 07/03/08 09/10/31 Name(s) of Onsite Representative(s)1Titles(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible OfficiallTitle/Phone and Fax Number Contacted Sid Frymyer.Po Box 370 Battleboro NC 27809//252-4424805/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program Sludge Handling Disposal- Facility Site Review Effluent/Receiving Waters Laboratory Storm Water Section D; Summary of Find in/Comments Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Ron Boone RRO WO//919-791-4200/ T / 12- Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page # 1 NPDES yrtmo/day Inspection Type 31 NC0077437 11 12I 07/03/08 117 18ICI Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Page # 2 Permit: NCO077437 Owner - Facility: Battleboro plant Inspection Date: 03/08/2007 Inspection Type: Compliance Evaluation Laborato Yes No NA NE Are field parameters performed by certified personnel or laboratory? ■ ❑ ❑ 13 Are all other parameters(excluding field parameters) performed by a certified lab? ■ ❑ ❑ ❑ # Is the facility using a contract lab? ■ ❑ ❑ ❑ Is proper temperature set for sample storage (kept at 1.0 to 4.4 degrees Celsius)? ■ 110 ❑ Incubator (Fecal Coliform) set to 44.5 degrees Celsius+l- 0.2 degrees? ❑ ❑ ■ ❑ Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? ❑ ❑ ■ ❑ Comment: Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ■ ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge IN ❑ ❑ ❑ Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? ❑ ❑ ■ ❑ Is the facility as described in the permit? ❑ ❑ ■ ❑ # Are there any special conditions for the permit? ❑ ■ ❑ ❑ Is access to the plant site restricted to the general public? ■ ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ■ ❑ ❑ ❑ Comment; Plant is not described in permit. Record Keeping . Yes No NA NE Are records kept and maintained as required by the permit? ■ ❑ Cl ❑ Is all required information readily available, complete and current? ■ ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? ■ ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? ■ ❑ ❑ ❑ Is the chain -of -custody complete? ■ ❑ ❑ ❑ Dates, times and location of sampling ■ Name of individual performing the sampling ■ Results of analysis and calibration ■ Dates of analysis ■ Name of person performing analyses ■ Page # 3 Permit: NCO077437 Owner - Facility: Battleboro plant Inspection Date: 03/08/2007 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Transported COCs ■ Are DMRs complete: do they include all permit parameters? ■ ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ■ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? ■ ❑ ❑ ❑ Is the ORC visitation log available and current? ■ ❑ ❑ ❑ 1s the ORC certified at grade equal to or higher than the facility classification? ■ ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? ■ ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? ■ ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ❑ ❑ ■ ❑ Comment: Equalization Basins Yes No NA NE Is the basin aerated? ❑ ■ ❑ ❑ Is the basin free of bypass lines or structures to the natural environment? ■ ❑ ❑ ❑ Is the basin free of excessive grease? ■ ❑ ❑ ❑ Are all pumps present? ❑ ❑ ■ ❑ Are all pumps operable? ❑ ❑ ■ ❑ Are float controls operable? ❑ ❑ ■ ❑ Are audible and visual alarms operable? ❑ ❑ ■ ❑ # Is basin size/volume adequate? ■ ❑ ❑ ❑ Comment: These are actually sedimentation/neutralization basins: two in parallel. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ■ ❑ ❑ ❑ Is sample collected below all treatment units? ■ ❑ ❑ Cl Is proper volume collected? ■ ❑ ❑ ❑ Is the tubing clean? ■ ❑ ❑ ❑ Is proper temperature set for sample storage (kept at 1.0 to 4.4 degrees Celsius)? ■ ❑ ❑ ❑ Is the facility sampling performed as required by the permit (frequency, sampling type representative)? ■ ❑ ❑ ❑ Comment: Pump Station - Effluent Yes No NA NE Is the pump wet well free of bypass lines or structures? ■ ❑ ❑ ❑ Page # 4 Permit: NC0077437 Owner -Facility-. Battleboroplant Inspection Date: 03/08/2007 Inspection Type: Compliance Evaluation Pump Station - Effluent Yes No NA NE Are all pumps present? ■ ❑ ❑ ❑ Are all pumps operable? ■ ❑ ❑ ❑ Are float controls operable? ■ ❑ ❑ Cl Is SCADA telemetry available and operational? ❑ ❑ ■ ❑ Is audible and visual alarm available and operational? ■ ❑ Cl ❑ Comment: Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Comment: Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: Yes No NA NE Yes No NA NE WOOO ■ ❑ ❑ ❑ ❑❑-00 Page # 5 Georgoulias, Bethany From: Boswell, Angela <Angela.BoswelI@naes.com> Sent: Wednesday, October 12, 201610:40 AM To: Georgoulias, Bethany Cc: Herring, David; Alexander, Laura; Bennett, Bradley Subject: RE: NCS000350 - Stormwater Permit Delegation of Signatory Authority Thanks Bethany... 1) Lat/Long for each SDO — Lat/Long for the facility is all we have at this time ... We'll check into this in efforts to obtain Lat/Long for each SDO. 2) Outfalls - The bulk of all contributing plant runoff waters from a storm event (rain) is dispensed into the sedimentation pond and subsequent effluent via SD01. •3 SD02 - SD05 identified outfalls are based on plant topography and deemed what was referred to by our last storm water regulatory review (NCDEQ-DWR) as "sheet flow". 3) eDMR — 10-4...Thanks... Thoughts? Thanks... Angefa, BoswetT Compliance Technician at Edgecombe Genco, LLC with NAES Corporation Address: PO Box 370 (Bill to), 6358 Old Battleboro Rd (Ship to), Battleboro, NC 27809 Office Phone: 252-442-0708 (Ext 406); Fax: 252-442-0990, email: Angela.Boswell(a-naes.com From: Georgoulias, Bethany fma!Ito:bethany.georgouIias(dncdenr.4ov] Sent: Wednesday, October 12, 2016 10:07 AM To: Boswell, Angela Cc: Herring, David; Alexander, Laura; Bennett, Bradley Subject: RE: NCS000350 - Stormwater Permit Delegation of Signatory Authority Hi Angela, Thanks so much for following up. I was actually looking for the stormwater outfall lat/Ion coordinates. We can use the plant location coordinates for lack of anything else, but if you have them for SDO1, we prefer those coordinates. I'm not sure I understand why there is only one SDO (001) that is sampled analytically, but the others are only qualitatively monitored. Is SDO1 the only outfall with representative outfall status, or do all the other outfalls eventually drain to SDO1? Some clarification would be helpful. Update on eDMR: We are working towards the goal of setting up our database system to accept stormwater monitoring data through eDMR, like wastewater permits. However, we have a long way to get there, and chances are good NCDEQ will not be prepared to accept the data by December 215`. We are working on our implementation plan for EPA, and so they are aware that INC is behind on this step (as are several other states 1 think). Our resource constraints (we are down several staff right now) have made this deadline difficult to meet. We will be sending out communication to all permittees about that status in the next 1-2 months. Thanks, Bethany Bethany Georgoulias Environmental Engineer Stormwater Program, Division of Energy, Mineral, and Land Resources N.C. Department of Environmental Quality 919 807 6372 office bethyYxe- rF,ouliasPncdenr.gov ;. 1612 Mail Service Center, Raleigh, NC 27699-1612 (mailing) i 512 N. Salisbury Street, Raleigh, NC 27604 (location) Websile: http://deq.nc.gov/about/divisions/energy-mineral-land-resources/stonnwater -::::�''`Nothing Compares. Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Boswell, Angela[mailto:Aneela.Bosweil@naes.com] Sent: Wednesday, October 12, 2016 9:50 AM To: Georgoullas, Bethany<bethanv.eeoreoulias@ncdenr.eov> Cc: Herring, David <David.Herrine@naes.com>; Alexander, Laura <laura.alexander(@ncdenr.eov> Subject: RE: NCS000350 - Stormwater Permit Delegation of Signatory Authority Hey Bethany —Hope all is well ... Have a couple of things to touch base w/ you about... 1) 1 apologize for the delay in getting this info to you... ➢ List of each stormwater outfall: L The storm water detention pond outfall is recognized as: SDO within the permit - This is the only outfall identified within permit NCS000350. 1. The facility's Integrated SPCC/SWPPP recognizes (5) outfalls: a. The sedimentation pond as 0011 and (4) other locations S1302, SD03, SD04, and SD05. b. Edgecombe performs qualitative and analytical on 001, and qualitative only on SD02, SD03, SD04 and SD05. ➢ Latitude/longitude coordinates - Plant location is identified as: Latitude: 36.036537; Longitude: (minus) — 77.752048 2) EPA NPDES Electronic Reporting Rule — I'm understanding this rule also includes stormwater DMRs & that the Phase 1 deadline to be reporting electronically is December 21, 2016. ➢ What do we need to do to ensure we meet this deadline? Thoughts? Thanks... AngeCa Bosweff Compliance Technician at Edgecombe Genco. LLC with NAES Corporation Address: PO Box 370 (Bill to); 6358 Old Battleboro Rd (Ship to). Battleboro. NC 27809 Office Phone: 252-442-0708 (Ext 406), Fax: 252-442-0990. email: Angela.Boswell@naes.com kA NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor ' Director ' June 11, 2010 Mr. Richard S. Frymyer Edgecombe Genco, LLC P.O. Box 370 6358 Old Battleboro Road Battleboro, NC 27809 Subject: Draft NPDES Stormwater Permit Permit No. NCS000330 Cogentrix Edgecombe Genco, LLC 6358 Old Battleboro Road Meektenbl�v► urg County Dear Mr. Frymyer: a Dee Freeman Secretary Enclosed with this letter is a copy of the draft stormwater permit for your facility. Please review the draft very carefully to ensure thorough understanding of the conditions and requirements it contains. The draft permit contains the following significant changes from this facility's current permit: Analytical monitoring changes: 1. Analytical monitoring parameters have been added to this permit. 2. pH has been added to the analytical monitoring requirements. 3. All analytical monitoring has been set to semi-annually during a representative storm event as defined in Part II Section B. The permittee must also document the total precipitation for each event. If no discharge occurs during the sampling period, the permittee must submit a monitoring report indicating "No Flow" within 30 days of the end of the six-month sampling period. Additionally, samples must be taken a minimum of 60 days apart, as specified in Table 2. 4. Benchmarks for analytical monitoring have been added to this draft permit. Exceedances of benchmark values require the permittee to increase monitoring, increase management actions, increase record keeping, and/or install stormwater Best Management Practices (BMPs) in a tiered program. If the sampling results are above a benchmark value, or outside of the benchmark range, for any parameter at any outfall then the facility shall follow the Tier 1 guidelines which require a facility inspection within two weeks and implementation of a mitigation plan within two months. If during the term of this permit, the sampling results are above the benchmark values, or outside of the benchmark range, for any specific parameter at a specific discharge outfall two limes in a row (consecutive), then the facility shall follow the 'Pier 2 guidelines which require a repetition of the steps listed for Tier 1 and also immediately institute monthly monitoring for all parameters (except Mercury) at every outfall where a sampling result exceeded the benchmark value for two consecutive samples. See Part II, Section B. of permit text. 5. You are required to collect all of the analytical and qualitative monitoring samples during representative storm events as defined in Part 11 Section B. Qualitative monitoring is required regardless of representative outfall status. 6. You are responsible for all monitoring until the renewal permit is issued. See Footnote 1 of Tables 1, 4, and 5. Wetlands and ,StonnwaterBranch One1 1617 Mail Service Center, Raleigh, Nwh Carolina 27699-1617 NOrthCar011na P oa e: 9 M 7 Salisbury St. Raleigh, North4941 Carolina 27604 r Service: �mma rl y Phone: 919�07-63DD I FAX, 8f9�D7-64941 Customer Service:1-877�23�i748 L LI Inteme1: www.ncwa1erquality.org An Equal Opportunity 1 Affirmative Action Employer Mr. Richard S. Frymyer Edgecombe Genco, LLC Permit No. NCS000350 7. The flow reporting requirement has been removed per DWQ revised strategy. (The total'rainfall parameter is in this permit, however.) 8. Vehicle maintenance monitoring has been revised to semi-annually in order to coincide with analytical and qualitative monitoring. Monitoring for TPH has replaced Oil & Grease. This requirement appears in all Individual Stormwater permits, however it only applies to facilities that do vehicle maintenance. If the facility begins vehicle maintenance during the permitted timeframe then the requirements shall apply. Other permit changes: 1. Additional guidance is provided about the Site Plan requirements. The site map must now identify if the receiving stream is impaired and if it has a TMDL established. It must also describe potential pollutants in each outfall. The map requirements are stated more explicitly. And, the site plan must contain a list of significant spills that have occurred in the past three years and also must certify that the outfalls have been inspected to ensure that they do not contain non-stormwater discharges. Additional information is provided in Part II Section A. 2. Additional requirements for the Stormwater Management Plan have been specified in Part II Section A. More details regarding secondary containment are provided. 3. Additional requirements for the Stormwater Pollution Prevention Plan have been specified in Part II . Section A. The plan must also be updated annually to include a list of significant spills and to certify `that the outfalls do not contain non-stormwater discharges. 4. The facility must now implement a semi-annual Facility Inspection Program of the site's stormwater management controls as specified in Part 11 Section A. 5. Information regarding the No Exposure Exclusion has been added to this draft permit. If industrial materials and activities are not exposed to precipitation or runoff as described in 40 CFR §122.26(g), the facility may qualify for a No Exposure Exclusion from NPDES stormwater discharge permit requirements. Additional information is provided in Part I Section A. 6. Per the requirements of the Tar -Pamlico Riparian Buffer Rule, all stormwater drainage from portions of this site that have been constructed after January 1, 2000 must be discharged through a correctly designed level spreader or another device that meets diffuse flow requirements per 15A NCAC 2B .0261. Diffuse flow requirements are described in Chapter 8 of the North Carolina Stormwater BMP Manual, available at: http://portal.ncdenr.org/web/wq/ws/su/bmp-manual. 7. In addition to submitting two signed copies of DMRs to Central Files, a separate signed Annual Summary DMR copy must be submitted to the local DWQ Regional Office by March 1 of each year (see Part III, E. 2. of permit). Please submit any comments to me no later than thirty (30) days following your receipt of the draft. Comments should be sent to the address Iisted at the bottom of this page. If no adverse comments are received from the public or from you, this permit.will likely be issued in about two months. If you have any questions or comments concerning this draft permit, contact me at (919) 807-6379 or jennifer.jones@ncdenr.gov. cc: Raleigh Regional Office, Dave Parnell Stormwater Permitting Unit Files Attachments Sincerely, X-1-4 Jennifer Jones Environmental Engineer Stormwater Permitting Unit ti 2 NCS000350 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY PERMIT TO DISCHARGE STORMWATER UNDER THE n In compliance with the provisions of North Caroiin standards and regulations promulgated and adopted Management Commission, and the Federal Water P; EM 1 StatiiW143-215.1, other lawful orth Carolina Environmental 3 ontrol Act, as amended, Edgecombe'Genco, LLC isch�a'rr�g,e stormwater from a facility located at is hereby authorizlehto,�.d Eddombe Genco, LLC 6358O1d Battleboro Road Battleboro, NC Edgecombe County to receiving waters designated as Beech Branch, a class C, NgSW stream in the Tar -Pamlico River Basin, in accordance with the discharge limitations, monitoring requirements, and other conditions set forth in Parts I, II, III, IV, V and VI hereof. Note: Draft Permit Dates are Approximate This permit shall become effective September 1, 2010. This permit and the authorization to discharge shall expire at midnight on August 31, 2015. Signed this day August 15, 2010. for Coleen H. Sullins, Director Division of Water Quality By the Authority of the Environmental Management Commission Permit No. NCS000350 TABLE OF CONTENTS PART I INTRODUCTION Section A: Individual Permit Coverage Section B: Permitted Activities Section C: Location Map PART II MONITORING, CONTROLS, AND LW!TATWNS FOR PERMITTED rT •'� T% DISCHARGES' Section A: Stormwater Pollution Prevention Plan � Section B: Analytical Monitoring Requi" men p' Section C: Qualitative Monitoring Requirements Section D: On -Site Vehicle Maintenance: Monitoring Requirements PART III STANDARD CONDITIONS FOR NPDES•STORMWATER INDIVIDUAL PERMITS -, Section A: Compliance and Liability 1. Compliance Schedule 2.. • Duty to Comply 3. Duty to Mitigate 4. Civil and Criminal Liability 5. Oil and Hazardous Substance Liability 6. Property Rights 7. Severability 8. Duty to Provide Information 9. Penalties for Tampering 10. Penalties for Falsification of Reports Section B: General Conditions 1. Individual Permit Expiration 2. Transfers 3. Signatory Requirements 1 • a ' Permit No. NCS000350 4. Individual Permit Modification, Revocation and Rcissuance, or Tennination 5. Permit Actions Section C: Operation and Maintenance of Pollution Controls 1. Proper Operation and Maintenance 2. Need to Halt or Reduce Not a. Defense 3. Bypassing of Stormwater Control Facilities Section D: Monitoring 1. and Records �. 2. Representative Sampling Recording Results 3. Flow Measurements + 4. , Test Procedures 5. Representative Out -I 6. Records Retention 1 ,,. 7. Inspectiand Entr on',y Section E: Reporting f Requirements 1. Discharge Monitoring Reports .2. Subim�tng'Reports 3. Availability of Reports 4. Non-Stormwater Discharges 5. Planned Changes 6. Anticipated Noncompliance. 7. Bypass, 8. Twenty-four Hour Reporting 9. Other Noncompliance 10. Other Information PART N LIMITATIONS REOPENER PART V ADMINISTERING AND COMPLIANCE MONITORING FEE REQUIREMENTS PART VI DEFINITIONS t' It Permit No. NCS000350 PART I 'INTRODUCTION 10 SECTION A: INDIVIDUAL PERMIT COVERAGE During the period beginning on the effective date of the permit and lasting until expiration, the permittee is authorized to discharge stormwater associated with industrial activity. Such discharges shall he controlled, limited and monitored as specified in this permit. If industrial materials and activities are not exposed to precipitation or runoff as described in 40 _CFR § 122.26(g), the facility may qualify for a No Exposure Exclusion from NPrDES stormwater discharge permit requirements. Any owner or operator�wishingto obtain a No Exposure Certification must submit a No Exposure Certification"NOI�form to the,Divi.sion; must receive approval by the Division; must maintain no expo sure ';conditiorisJinless authorized to discharge under a valid NPDES stormwater permit; and must reapply for the No Exposure Exclusion once every five (5) years. ' SECTION B: PERMITTED ACT Until this permit expires or is modified or. 'revoked; the permittee is authorized to discharge stormwater to the surface waters -of North Carolina or separate storm sewer system that has been adequately treated and managedJn accordance with the terms and conditions of this individual permit. All stormwater discharges shall-be`in accordance with the conditions of this permit. Any other point source discliargc�td surface waters of the state is prohibited unless it is an allowable non-stormwater discli ge or is covered by another permit, authorization, or approval. The stormwater discharges allowed by this individual permit shall not cause or contribute to violations of Water Quality Standards. This permit does not relieve the permittee from responsibility for compliance with any other applicable federal, state, or local law, rule, standard, ordinance, order, judgment, or decree. Part I Page 1 of 2 Z 3o Z aSL'd I PLd iiopinol A;IIppej r rd row., (ulseg JaAlb UlEd-lej) ZO-EO-EO :uiSEq-qnS MSN 'D :Ssep WE,)AS yjutla tip,-u u1111 mueto{;5 Gui,yc+x+zi i-K4,uU.leb .>j-4ullul M l,9[ ,t"S aU :ONr41G.lu N ,ITT ,ZO o4E :&PMlEq Z)N 10.10claplea J 1 I 'uivaJ ;6(Ituujaf I)j S OSEOOOSDN Jf, ti., ,��t., .+wti1lr�y+"14�.^q•�,kfX� /, f f� rr'r•^r . :. +'S — ` i77tx i' ;ir �l ' 1', �5•IrT,5 f.»ti..` �Mx `o I n LTA, - �.•�"�Lrifrrgy„.�Ilj l�`i`,v�ry,^.ti hh. ��. �oti, r;� y. r, ,4✓,j+'Yf i� r�;'�•e. :' •.yr',r�l i'_r 1 ! L rr tv-:1r';•,, 4 +.,<: ti *:.s k� 'y.;,; :! , I _ ,•rr' y�' i_ lh i`� ,i,t,r Il ;., �,,,�;( �'--a.���' ,,ti 1 F�� �'•,��-'�..'_ �..1� /.ri _„y. ,y� JJ ,�'•,� _---^' r r,' -,N _ f tt� i++f '+,f �... y.. � o � .. t I � t. w e � �.� �., I -. !!- �. Jay 3.� { �' s:�J:• rj w f .irk, r •S t�" �w J i I 1 tirr' . ,i rizJ��.. r i .It 'd..^,, �� r t f *A � � e ' �" f r } w�� i .>_ti � �r-'� '-. 1 1i1. f ° �'' _.,�' f, � 1°� `'^�r j� - Lil �:•..?.:4t'. J' � 11 � ».t•I ti- � , � •Jrr{� IfJrrl , f I .-� sf! j"y�j4 y a '' � % � �' h 5jv �'J •� :r�' �'• rk 1r, : r^ .r' S .r, t :,.� S %t r y R,.`. Ys. ar%`, All • 6` _ �� X s.r•+. M i k I I ! �; r u' J.. ,>yf - :;A, . ?1L. taffy r'._, 3 �--I,!(},J+ w lr�Y k.., •} �+ •/ y ✓ {r !* r «+ +?^ELwV IJ 1". �:":o=. '�i~' •�` Y 1. '•fit, I .?, ry"+���+�' R�AF�rr�+r '- jr 'l r — _ ��� � r r• �: �� �y � ��+ is ��`: ...��_.:�, f �� "� f IQ �..•ti, Mb,."tifw`..;._,�'7•..':�..:::.�.•��l„,;„�,,;,,,M'i 51! I1• r ir.'_` "+1�-'. '.p "9 t�� j�am�j, 1��+.• jj ••ti 14 Isti.e� ��'� ;.� � `�]}•�4Y i !�� �• � :W , Jy1 r F'� til r +� i"��ri4i'r �\ r�,. �I�k ��. • .v�' � 1.✓7- ,�;J -� Jf ;� 53F�r`Ji li df �,r� 0I'~` �I y i-•, ��(jjJJ11 i, ZX ka ii �++ � .II .�lr �' ��• f '�F• �rcJ � c �J y 1� lug " fir.r�� c, rarYi y)/Q:'fi 4 ' yx! i -rs '% r A yam' .�f.t ` DIX .ks rxylyr^ 1 y wY tiff y� ;." +'''•, r rI �S`�� �I*,Igti���y•�4�;1�r ��.a ��',:?�'�rY�, *15'sl 1 ;� `fC IY'+C� 5','I •'`."y Y1 r r, �t q{n� k,-�5� � '� y�J�F �� �J ��� � ryy'Si 1` . ' 0 f'�--N'� � '. �vl • a�.ti'tti•�, » �N•. �� f� 1 +�� -• r X1. L � •5.41�..e,r�-�.1� --- ri i r.' , 'il tir �dA' 15. I'6'F•� i t7 ntp �.�{+ :: �1 � �J r....�, 14.''`,. 91 i 09ROOSDu 'ON Tad dvty NollvDorl :a I oljl�)gS i 09ROOSDu 'ON Tad dvty NollvDorl :a I oljl�)gS Permit No. NCS000350 PART H MONITORING, CONTROLS, AND LIMITATIONS FOR PERMITTED DISCHARGES SECTION A: STORMWATER POLLUTION PREVENTION PLAN The Permittee shall develop a Stormwater Pollution Prevention Plan, herein after referred to'as the Plan. This Plan shall be considered public,information in accordance'with Part 111, Standard Conditions, Section E, Paragraph 3 of this individual permit. The Plan shall include, at a minimum, the following items: Site Plan. - The site plan shall provide a description of the -physical facility and the potential pollutant sources which may be expected to coniribute to contamination of stormwater discharges. The site plan shall contain the.followin - (a) A general location map (USGS quadrafi& map or appropriately drafted equivalent map), showing the facility's location in relation to. transportation routes and surface waters, thname f the re eivi e o ng water(s) to which the stormwater outfall(s) discharges, or%if the discharge is to a municipal separate storm sewer system, the name'of�rthe municipality and the ultimate receiving waters; and accurate latitude and' ongitude of the point(s) of discharge. The general location'map,(or alternatively the site map)'shall identify whether each receiving water is irmpaired'(on the state's 303(d) list of impaired waters) or is located in a watershed,for;which a TMDL has been established, and what the -11 parameter(s) of concern+are. North Carolina.'s 303(d) List can be found here: http:llh2o.enr.,stiite.ne.us/tmdl/General-303d.htm#Downloads North Carolina TMDL documents can be found here: httR://h2o.enr.sta'te.ne.us/tmdl/TMDL list.htm#Final TMDLs. (b) A narrative description of storage practices, loading and unloading activities, outdoor process areas, dust or particulate generating or control processes, and waste disposal practices. A narrative description of the potential pollutants which could be expected to be present in the stormwater discharge from each outfall. (c) A site map drawn to scale (including a distance legend) showing: the site property boundary, the stormwater discharge outfalls, all on -site and adjacent surface waters and wetlands, industrial activity areas (including storage of materials, disposal areas, process areas, loading and unloading areas, and haul roads), site topography, all drainage features and structures, drainage areas for each outfall, direction of flow in each draipage area, industrial activities occurring in each-" ' drainage area, buildings, existing BMPS, and impervious surfaces. The site map must indicate the percentage of each drainage area that is impervious. Part II Page 1 of 1 l Permit No. NCS000350 K is (d) A list of significant spills or leaks of pollutants that have occurred at the facility during the three (3) previous years and any corrective actions taken to mitigate spill impacts. (e) Certification that the stormwater outfalls have been evaluated for the presence of non-stormwater discharges. The certification statement will be signed in accordance with the requirements found in Part IIl, Standard Conditions, Section Paragraph 3. The permittee shall, re- certify annually that the stormwater outfalls have been evaluated for the presence of non-stormwater discharges. Stormwater Management Plan. The stormwater management plan shall contain a narrative description of the materials management practices employed which control or minimize the exposure of significant materials too stor'm�water, including structural and nonstructural measures. The stormwater managcme�nt plan, at a;minimum, shall A,f"�%/ incorporate the following: (a) Feasibility Study. A review of the technical'and economic feasibility of changing the methods of operations and/or storage practices to eliminate' or reduce exposure of materials and processes to stor`m�w,ateWherever practical, the permittee shall prevent exposure of all storageareas, material handling operations, and manufacturing or fueling operations. Tn areas where elimination of exposure is not practical, the,stormwater management plan shall document the feasibility of diverting the stonnVvdter riZfffeaway from areas of potential contamination. (b) Secondary ConfainmentnRequirements and Records. Secondary containment is required for: bulk storage of liquid materials; storage in any amount of Section 313 of Title 11-11 f:thd-Superfund Amendments and Reauthorization Act (SARA) water priority ch micals; and storage in any amount of hazardous substances, in order to prevent leaks and spills from contaminating stormwater runoff. A table or summary of all such tanks and stored materials and their associated secondary containment areas shall be maintained. If the secondary containment devices are connected directly to stormwater conveyance systems, the connection shall be controlled by manually activated valves or other similar devices (which shall be secured closed with a locking mechanism), and any stormwater that accumulates . in the containment area shall be at a minimum visually observed for color, foam, outfall staining, visible sheens and dry weather flow,,prior to release of the accumulated stormwater. Accumulated stormwater shall be released if found to be uncontaminated by the material stored within the containment area. Records documenting the individual making the observation, the description of the accumulated stormwater, and the date and time of the release shall be kept for a period of five years. (cy BMP Summary. A listing of site structural and non-structural Best Management Practices (BMP) shall be provided. The installation and implementation ofBMPs shall be based on the assessment of the potential for sources to contribute significant quantities of pollutants to stormwater discharges and data collected Part 11 Page 2 of 11 Permit No. NCS000350 through monitoring of stormwater discharges. The BMP Summary shall include a written record of the specific rationale for installation and implementation of the selected site BMPs. The BMP Summary shall be reviewed and updated annually. 3. Spill Prevention and Response Plan. The Spill Prevention and Response Plan (SPRP) shall incorporate an assessment of potential pollutant sources based on a materials inventory of the facility. Facility personnel (or the team) responsible for implementing the SPRP shall be identified in a written list incorporated into the SPRP and signed and dated by each individual acknowledging their responsibilities for the plan. A responsible person shall be on -site at all times during facility operations that have the potential to contaminate stormwater runoff through spills or exposure of materials associated with the facility operations. The SPRP must be site stormwater specific. Therefore, an oil Spill Prevention Control and Countermeasure plan (SPCC)'may be a component of the SPRP, but may not be sufficient to completely address.'the stormwater aspects of the SPRP. The common elements of the SPCC with the SPRY,may'be incorporated by reference into the SPRP. 4. Preventative Maintenance and Good HousekeepinjPi•ogram. A preventative maintenance and good housekeeping'prograrwshall be developed. The program- shall list all stormwater control systems, stormwater discharge outfalls, all on -site and -adjacent surface waters and wetlands, industrial activity areas (including material storage areas, material handling areas,.disposal.areas, process areas, loading and unloading areas, and haul roads), all drainage feat res and.structures, and existing structural BMPs. The program shall establish schedules,of irispections,-maintenance, and housekeeping activities of stormwatercontrolsysfeins, as well as facility equipment, facility areas, and facility systems that present a potential, for stormwater exposure or stormwater pollution. Inspection of material-Tiand ling areas and -regular cleaning schedules of these areas shall be incorporated into the"program. Timely compliance with the established schedules for inspections, maintenance,. and housekeeping shall be recorded in writing and maintained in the SPPP. 5. Employee Training. Training programs shall be developed and training provided at a minimum on an annual basis for facility personnel with responsibilities for: spill response and cleanup, preventative maintenance activities, and for any of the facility's operations that have the potential to contaminate stormwater runoff. Facility personnel (or team) responsible for implementing the training shall be identified, and their annual training shall be documented by the signature of each employee trained. 6. 'Responsible Party. The Stormwater Pollution Prevention Plan shall identify a specific position(s) responsible for the overall coordination, development, implementation, and revision to the Plan. Responsibilities for all components of the Plan shall be documented and position assignments provided. 7. Plan Amendment. The permittee shall amend the Plan whenever there is a change in design, construction, operation, or maintenance which has a significant effect on the potential for the discharge of pollutants to surface waters. All aspects of the Stormwater Part II Page 3 of 11 Permit No. NCS000350 Pollution Prevention Platt shall be reviewed and updated on an annual basis. The annual update shall include an updated list of significant spills or leaks of pollutants for the previops three years; or the notation that no' spills have occurred. The annual update shall include re -certification that the stormwater outfalls have been evaluated for the presence of non-stormwater discharges. Each annual update shall include a re-evaluation of the effectiveness of the BMPs listed in the BMP Summary of the Stormwater Management Plan. The Director may notify the permittee when the Plan does not meet one or more of the minimum requirements of the permit. Within 30 days of such notice, the permittee shall submit a time schedule to the Director for modifying the Plan to meet minimum requirements. The permittee shall provide certification inwriting (in accordance with Part III, Standard Conditions, Section B, Paragraph 5) to& Director that the changes have been made. NYC. Facility Inspections.. Inspections of the facilit; part of the Preventative Maintenance and Go( -a semi-annual schedule; once during the firs during the second half (July to December), w dates (unless performed more frequently than are different from, and in addition to, .thd`stor required in Part II B, C a d`D oftt sdpe it. all storriiwater systems shall occur as �asekeeping Program at a minimum on ofithe year (January to June), and once AW least 60 days separating inspection -annually). These facility inspections er discharge characteristic monitoring .9. Implementation. The permitteeF'JNiI1N*' shallM i.TFmplement the Plan. Implementation of the Plan shall include documentation of a ilmonitoring, measurements, inspections, maintenance activities, and training provided'to employees, including the log of the sampling data and of actions taken to 41p ment'BMPs associated"with the industrial activities, including vehicle maintenance activities. Such documentation. shall be kept on -site for a period of five years and made available to the Director or the Director's authorized representative immediately upon request. Part II Page 4 of 1 I Permit No. NCS000350 SECTION B: ANALYTICAL MONITORING REQUIREMENTS Analytical monitoring of stormwater discharges shall be performed as specified in Table 1. All analytical monitoring shall be performed during a representative storm event. The required monitoring will result in a minimum of ten analytical samplings being conducted over the term of the permit at each stormwater discharge outfall (SDO). A representative storm event is a storm event that measures greater than 0.1 inches of rainfall. The time between this storm event and the previous storm event measuring greater than 0.1 inches must be at least 72 hours. A single storm event may have a period of no precipitation of up to 10 hours. For example, if it rains but stops before producing any collectable discharge, a sample may be collected if the next rain ( producing a discharge begins within 10 hours. f Table 1. Analytical Monitoring Requirements' ,. 'Discharge :::Measurement :Sample;. <' Ample:,:-:,- Characteristics: ..:: :: Units _ -Fre uenc 1.,. a, ;. T e� :':'.. Ltication3' 40 CFR Part 423 Appendix A: €�' ' f Grab SDO 13 Priority Pollutant Metals µg/l r i semi-annual (Ag, As, Be, Cd, Cr, Cu, Hg, Ni, Pb, Sb, Se, Tl, Zn)a� ta.Fy. Al �; "+ ' j' :, '�; ' semi-annual Grab SDO B semi-annual Grab SDO:.. COD m � 1 semi-annual Grab SDD . TSS semi-annual Grab F SDO Sulfate mg/1 semi-annual Grab SDO Oil and Grease O&G) m semi-annual Grab SDO H standard semi-annual Grab SDO Total Rainfalls inches semi-annual Rain Gauge - Footnotes: I Measurement Frequency: Twice per year during a representative storm event, for each year until either another permit is issued for this facility or until this permit is revoked or rescinded. If at the end of this permitting cycle the permittee has submitted the appropriate paperwork for a renewal permit before the submittal deadline, the permittee will be considered for a renewal application. The applicant must continue semi-annual monitoring until the renewed permit is issued. See Table 2 for schedule of monitoring periods through the end of this permitting cycle. 2 If the stormwater runoff is controlled by a stormwater detention pond, a grab sample of the discharge from the pond shall be collected within the first 30 minutes of discharge. 3 Sample Location: Samples shall be collected at each stormwater discharge outfall (SDO) unless representative outfall status has been granted. 4 Mercury shalt be analyzed by EPA Low-level detection method 1 b31 E. This method also requires a field blank be analyzed. A benchmark does not apply; however, values above 0.012 µg/l should be noted on annual SDO DMR reports to the Regional Office. Part II Page 5 of 11 Permit No, NCS000350 5 For -each sampled representative storm event the total precipitation must be recorded. An on -site rain gauge or local rain gauge reading must be recorded. The permittee shall complete the minimum ten analytical samplings in accordance with the schedule specified below in Table 2. A minimum of 60 days must separate each sample date unless monthly monitoring has been instituted under a Tier Two response. Table 2. Monitoring Schedule Moaitorin '` eriod,' f.� ;;;Sample Number.;:: - Start End Year 1 — Period 1 1 September 1, 2010 Februar 28, 2011 Year 1 — Period 2 2 March 1, 2011 August 31, 2011 Year 2 — Period 1 3 September 1,.,2011 February 29, 2012 Year 2 — Period 2 4 Mardhls,,2012 August 31, 2012 Year 3 — Period 1 5 Se`tember 1 2012; ¢ Februag 28, 2013 Year 3 — Period 2 6 � March 1, 2013 August 31, 2013 Year 4 — Period 1 7 Se "teinber.,1, 2013 February28, 2014 Year 4 — Period 2 8 40,"t Mardi i, 2014 August 31, 2014 Year 5 — Period 1 9 „ A 45e� r&ber 1, 2014 February28, 2015 Year 5 — Period 2 10 �: „w, March 1, 2015 Au ust 31, 2015 Footnotes:�� f:�„se 1 Maintain semi-annual monitoring during!permit,renewal process. The applicant -must continue semi-annual s'wk:.<.w . IVmonitoring until the renewed permit is issued: 2 If no discharge occurs during the sampling riod, the permittee must submit a monitoring report indicating "No Flow" within 30 days of tge end of the six-month sampling period. , - -The Perm, itfee shall report the nalytical results from the first sample with valid results within the monitoring period. In addition, a separate signed Annual Summary DMR copy shall be submitted to the local DWQ Regional Office (RO) by March 1 of each year. The permittee shall compare monitoring results to the benchmark values in Table'3. The benchmark. values in Table 3 are not permit limits but should be used as guidelines for the permittee's Stormwater Pollution Prevention Plan (SPPP). Exceedences of benchmark values require the permittee to increase monitoring, increase management actions, increase record keeping, and/or install stormwater Best Management Practices (BMPs) in a tiered program. See below the descriptions of Tier One and Tier Two. Part II Page 6 of I I Permit No. NCS000350 Table 3. Benchmark Values for Analytical Monitoring Discharge Chairacteristtc's :'. Units Berichniark Aluminum mg/1 0.75 Antimony N. mg/l . 0.09 Arsenic mg/l 0.36 Beryllium mg/l 0.07 Boron mg/1 N/A Cadmium mg/l 0.001 Chromium mg/l 1 Copper mg/1 ,� NO3�0 007 Lead mg/l003_�/ .j .F Mercury µg/l ' , N/A ;� :ti"', Nickel mg/l .; � 0.26 Selenium mg/l,,r If- 0.056 Silver eq mg/l=�,f, • %' 0.001 Thallium "ing/L"~� NIA Zinc rF mg/l 0.067 COD ; J mg/l 120 TSS`` ,. ,� mg/l 100 Sulfate mg/l 500 O&G mg/l 30 pH (see footnote 1) standard 6-9 t Footnotes; 1 If pH values outside this range are recorded in sampled stormwater discharges, but ambient rainfall data indicate precipitation pH levels are within + 0.1 standard units of the measured discharge values or lower, then the lower threshold of this benchmark range does not apply. Readings from an on -site or local rain gauge (or local precipitation data) must be documented to demonstrate background concentrations were reiow the benchmark pH range. N Part 11 Page 7 of I I Permit No. NCS000350 If: The first valid sampling results are above a benchmark valu6, or outside of the benchmark ranc, for any parameter at any outfall; Then: The permittee shall: 1. Conduct a stormwater management inspection of the facility within two weeks of receiving sampling results. 2. Identify and evaluate possible causes of the benchmark value exceedence. 3. Identify potential, and select the specific: source controls, operational controls, or physical improvements to reduce concentrations of the parameters of concern, or to bring concentrations to within the benchmark range. 4. Implement the selected actions. -Within two moue s of?"lith(e",inspection. 5. Record each instance of a Tier One response in,the'Storinwa-ier Pollution Prevention Plan. Inclede the date and value of the benchmark! exbQence, the inspection date, the personnel conducting the inspection, the selected actiphsAnd the"clate the selected actions were .Ar implemented. All Tier T If. During the term of this permit,,, e rsf'valid sampling results from two consecutive le 10-6 monitoring periods are above the benchmark values, or outside of the benchmark range, for any specific parameter at a spe'c'ific,discharge outfall; Then: The permittee shall: I. Repeat all the required actions outlined above in Tier One.. 2. Immediately institute monthly monitoring for all parameters (except mercury) at every outfall where a sampling result exceeded the benchmark value for two consecutive samples. Monthly (analytical and qualitative) monitoring shall continue until three consecutive sample results are below the benchmark values, or within the benchmark range, for all parameters at that outfall. 3. If no discharge occurs during the sampling period, the permittee is required to submit a monthly monitoring report indicating "No Flow." 4. Maintain a record of the Tier Two response in the Stormwater Pollution Prevention Plan. Part 11 Page 8 of 11 Permit No. NCS000350 During the term of this permit, if the valid sampling results required for the permit monitoring periods exceed the benchmark value, or are outside the benchmark range, for any specific parameter at any specific outfall on four occasions, the permittee shall notify the DWQ Raleigh Regional Office Supervisor in writing within 30 days of receipt of the fourth analytical results. DWQ may, but is not limited to: • Require that the permittee increase or decrease the monitoring frequency for the remainder of the permit; • Work with the permittee to develop alternative response strategies; ` • Require the permittee to install structural stormwater§ co" trols; " • Require the permittee to implement other stormwater"control measures; or • Require that the perm'ittee implement site modifications to qualify for the No Exposure Exclusion. .:,`� SECTION C: QUALITATIVE<MONITORING REQUIREMENTS Qualitative monitoring requires a visual iris`A ection of each stormwater outfall regardless of .�- g representative outfall status and.shdll be performed as specified in Table 4, during the analytical .monitoring event. [If analyticalfmonitoring is not required, the permittee still must conduct semi- annual qualitative monitoring.] Qualitative monitoring is for the purpose of evaluating the effectiveness of the Stormwafer _Pollution Prevention Plan (SPPP) and' assessing new sources of stormwater pollution. In the event an atypical condition is noted at a stormwater discharge outfall, the permittee shall document the suspected cause of the condition and any actions taken in response to the discovery. This documentation will be maintained with the SPPP. Table 4. QuaIitative Monitoring Requirements Dise.harge Characteri5ties'...::::,;;`; Frequency) '_ f Monitoring . Location2 Color semi-annual SDO Odor semi-annual SDO Clarity semi-annual SDO Floating Solids semi-annual SDO Suspended Solids semi-annual SDO Foam semi-annual SDO Oil Sheen semi-annual SDO Part II Page 9 of I I Permit No. NCS000350 Erosion or deposition at the semi-annual SDO outfall Other obvious indicators semi-annual SDO of stormwater pollution Footnotes: 1 Measurement Frequency: Twice per year. during a representative storm event, for each year until either another permit is issued for this facility or until this permit is revoked or rescinded. if at the end of this permitting cycle the permittee has submitted the appropriate paperwork for a renewal permit before the submittal deadline, the permittee will be considered for a renewal application. T�e applicant must continue semi-annual monitoring until the renewed permit is issued. See Table'2 for schedule of monitoring periods through the end of this permitting cycle. 2 Monitoring Location: Qualitative monitoring shall be performed at each stormwater discharge outfall (SDO) regardless of representative outfall status. 4 SECTION D: ON -SITE VEHICLE MAINTEN Facilities which have any vehicle maintenance 55 gallons of new motor oil per month when a analytical monitoring as specified below in Ta stormwater discharge outfalls which discharge areas and in accordance with the schedule Dres monitoring shall be performed during a Table 5. Analytical G REQUIREMENTS ina on=site which uses more than ove: Fthe calendar year shall perform ,his monitoring shall be performed at all atenrunoff from vehicle maintenance Table 2 (Section B). All analytical storm event. meets for On -Site Vehicle Maintenance Discharge Characteristics } Units eas,urement- Fre tieric 1 Y�Sample' "T ' .;Sample' L6cation3 H e�"j, 4standard semi-annual Grab SDO Total Petroleum Hydrocarbons EPA Method 1664 SGT-HEM mg/1 semi-annual Grab SDO Total Suspended Solids mg/1 semi-annual Grab SDO Total Rainfall4 inches semi-annual Rain gauge New Motor Oil Usagegallons/month I semi-annual Estimate - Footnotes: I Measurement Frequency: Twice per year during a representative storm event, for each year until either another permit is issued for this facility or until this permit is revoked or rescinded. If at the end of this permitting cycle the permittee has submitted the appropriate paperwork for a renewal permit before the submittal deadline, the permittee will be considered for a renewal application. The applicant must continue semi-annual monitoring until the renewed permit is issued. See Table 2 for schedule of monitoring periods through the end of this permitting cycle. 2 If the stormwater runoff is controlled by a stormwater detention pond a grab sample of the discharge from the pond shall be collected within the first 30 minutes of discharge from the pond. 3 Sample Location: Samples shall be collected at each stormwater discharge outfall (SDO) that discharges stormwater runoff from area(s) where vehicle maintenance activities occur. 1 For each sampled representative storm event the total precipitaiion must be recorded. An on -site or local rain •'gauge reading must be recorded. - Part 11 Page 10 of 11 Permit No. NCS000350 Monitoring results shall be compared to the benchmark values in Table 6. The benchmark values in Table 6 are not permit limits but should be used as guidelines for the permittee's Stormwater Pollution Prevention Plan (SPPP). Exceedences of benchmark values require the permittee to increase monitoring, increase management actions, increase record keeping, and/or install stormwater Best Management Practices (BMPs), as provided in Part II Section B. Table 6. Benchmark Values for Vehicle Maintenance Analytical Monitoring Discharge Characferistics ;,..: ''Units' Benchmark ` pH (see footnote 1) standard 6-91 Total Petroleum Hydrocarbons (TPH) mg/L 15 Total Suspended Solids mgl - k r!X 100 Footnotes: ;;� vA I If pH values outside this range are recorded in sampled stonTi ater,discharges, but ambient rainfall data indicate precipitation pH levels are within + 0.1 standard units;of�the measured values or lower, then the lower threshold of this benchmark range does not apply, Readings from an on -site or local rain gauge (or local precipitation data) must be documented to demonstrate background concentrations were below the normal pH range. - t Part II Page I I of 11 Permit No. NCS000350 ,PART III t STANDARD CONDITIONS FOR NPDES STORMWATER INDIVIDUAL PERMITS SECTION A: COMPLIANCE AND LIABILITY 1. Compliance Schedule The permittee shall comply with limitations and Controls specified for stormwater discharges in accordance with the. following schedule:, Existing Facilities already operating but applying for permit coverage for the first time: The Stormwater Pollution Prevention Plan shall be developed and implemented within 12 months of the effective date of the initial permit and updated thereafter on an annual basis. Secondary containment, as specified in Part 11, Section A, Paragraph 2(b) of this permit, shall be accomplished withizn,,12 months of the effective date of the initial permit issuance. Nt New Facilities applying for coverage for the first time a d exisfacilities previously permitted and Vt* ''r "WIX,, V applying for renewal under this permit: The StormwatefTollution Prevention Plan shall be developed and implemented prior to the beginning of discharges from42,operation of the industrial activity and be updated thereafter on an annual basis. Secondary containme' ,,' s.specificd in Part II, Section A, Paragraph 2(b) of this permit shall be accomplished prior to;the=iieginningof discharges from the operation of the industrial activity. Duty to Comply The permittee must comply with: a 11`conditibns.of this individual permit. Any permit noncompliance ti5'� � V� constitutes a violation of the Cl�eari Water Act land is grounds for enforcement action; for permit termination, revocation anddreissuanc"modification; or denial of a permit upon renewal application. a. The permittee shall comply..with standards or prohibitions established under section 307(a) of the Clean Water Act;fdntoxic'pollutants within the time provided in the regulations that'establish these standards or-prolubitions, even if the permit has not yet been modified to incorporate the requirement. b. The Clean Water Act provides that any person who violates a permit condition is subject to a civil penalty not to exceed $25,000 per day for each violation. Any person who negligently violates any permit condition is subject to criminal penalties of $2,500 to 25,000 per day of violation, or imprisonment for not more than 1 year, or both. Any person who knowingly violates permit conditions is subject to criminal penalties df $5,000 to $50,000 per day of violation, or r imprisonment for not more than 3 years, or both. ' Also, any person who violates a permit condition may be assessed'an administrative penalty not to exceed $10,000 per violation with the maximum amount not to exceed $125,000. [Ref: Section 309 of the Federal Act 33 USG 1319 and 40 CFR 122.41(a)] Understate law, a daily civil penalty of not more than ten thousand dollars ($10,000) per violation may be assessed against any person who violates or fails to act in accordance with the terms, conditions, or requirements of a permit. [Ref: NC General Statutes 143-215.6A]. d. Any person may be assessed an administrative penalty by the Director for violating section 301, 302, 306, 307, 308, 318 or 405 of the Act, or any permit condition or limitation implementing 4ny of such sections in a permit issued under section 402 of the Act. Administrative penalties for Class I violations are not to exceed $10,000 per violation, with the maximum amount of any Class I penalty assessed not to exceed $25,000. Penalties for Class II violations are not to exceed Part III Page I of 8 t i Permit No. NCS000350 $10,000 per day for each day during which the violation continues, with the maximum amount of any Class II penalty not to exceed $125,000. 3. Duty to Mitigate The permittee shall take all reasonable steps to minimize or prevent any discharge in violation of this' individual permit which has a reasonable likelihood of adversely affecting human health or -the environment. Civil and Criminal Liability Except as provided in Part III, Section C of this permit regarding bypassing of stormwater control facilities, nothing in this individual permit shall be construed to relieve the pettnittee from any responsibilities, liabilities, or penalties for noncompliance pursuant to NCGS 1421-215.3;143-215.6A, 143-215.6B, 143- 215.6C or Section 309 of the Federal Act, 33 USC 1319. Furthermore, the permittee is responsible for consequential damages, such as fish kills, even though the responsibility for,effective compliance may be temporarily suspended. f `{ �1' 5. Oil and Hazardous Substance Liability Nothing in this individual permit shall be construed'to preclude the institution of any legal action or relieve the permittee from any responsibilities, liabilities, or,penalties'to which the permittee is or may be subject to under NCGS 143-215.75 et seq. or Section'3 i I of the: Federal Act, 33 USC 1321. 6. Property Rights The issuance of this indryidual permit does not convey any property rights in either real or personal s;�nor does it authorize any injury to private property or any invasion of property, or any exclusive privlege personal rights, nor any infringement of Federal, State or local laws -or regulations. 7.. Severability - The provisions of this individual permit are severable, and if any,provision of this individual permit, or the application of any provision of this individual permit to any circumstances, is held invalid, the application of such provision to other circumstances, and the remainder of this individual permit, shall not be affected thereby. Duty -to Provide Information The permittee shall furnish to the Director, within a reasonable time, any information which the Director may request to determine whether cause exists for modifying, revoking and reissuing, or terminating the permit issued pursuant to this individual permit or to determine compliance with this individual permit. The permittee shall also furnish to the Director upon request, copies of records required to be kept by this individual permit. Penalties „for Tampering The Clean Water Act provides that any person who falsifies, tampers with, or knowingly renders inaccurate, any monitoring device or method required to be maintained under this individual permit shall, upon conviction, be punished by a fine of not more than $10,000 per violation, or by imprisonment for not more than two years per violation, or by both. If a conviction of a person is for a violation committed after a first conviction of such person under this paragraph, punishment is a fine of not more that $20,000 per day of violation, or by imprisonment of not more than 4 years, or both. Part III Page 2 of 8 Permit No, NCS000350 10. Penalties for Falsification of Report The Clean Water Act provides that any person who knowingly makes any false statement, representation, or certification in any record or other document submitted or required to be maintained under this individual permit, including monitoring reports or reports of compliance or noncompliance shall, upon conviction, be punished by a fine of not more than $10,000. per violation, or by imprisonment for not more than two years per violation, or by both. SECTION B: GENERAL CONDITIONS 0 3. Individual Permit Expiration The permittee is not authorized to discharge after the expiratio authorization to discharge beyond the expiration date, the A. required by the agency authorized to issue permits no later tha permittee that has not requested renewal at least 180 days prio have a permit after the expiration and has not requested. ne'W be subjected to enforcement procedures as provided:in. NCGS'i Transfers .:date`. In order to receive automatic Oi iitRshall submit forms and fees as are 180,:days;pr"ior to the expiration date. Any to expiration, or any permittee that does not i at least 180 days prior to expiration, will �143-215.6 and 33 USC 1251 et. seq. This permit is not transferable to any p ers�on-ex cept er notice to and approval by the Director. The Director may require modification or'revocation and reissuance of the permit to change the name and t:%' • 'TU . incorporate such other requirements ass may�be.necessary under the Clean Water Act. The Permittee is required to notify the Division in writing m1he event the permitted facility is sold or closed. Signatory Requirements All applications, reports,,6JfJhformation submitted to the Director shall be signed and certified. 1W yw a. All applications to be covered under this individual permit shall be signed as follows: (1) In the case of a corporation: by a principal executive officer of at least the level of vice- president, or his duly authorized representative, if such representative is responsible for the overall operation of the facility from which the discharge described in the permit application form originates; (2) In the case of a partnership or limited partnership: by a general partner; (3) In the case of a sole proprietorship. by the proprietor; (4) In the case of a municipal, state, or other public entity: by a principal executive officer, ranking elected official, or other duly authorized employee. All reports required by the individual permit and other information requested by the Director shall be signed by a person described above or by a duly authorized representative of that person. A person is a duly authorized representative only if: (1) The authorization is made -in writing by a person described above; (2) The authorization specified either an individual or a position having responsibility for the overall operation'of the regulated facility or activity, such as the position of plant Part III Page 3 of 8 Permit No. NCS000350 4. manager, operator of a well or well field, superintendent, a position of equivalent responsibility, or an individual or position having overall responsibility for environmental matters for the company. (A duly authorized representative may thus be either a named individual or any individual occupying a named position.); and „• �, (3) The writien authorization is submitted to the Director. C. Any person signing a document under paragraphs a. or b. of this section shall make the following certification: "I certify, urider penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my`' owledge and belief, true, accurate, s, &'; 'I:. and complete..1 am aware that there are significant penalties for submitting false information, kr rV VYA41k 4: including the possibility of fines and imprisonment for kriowingrviolations." The issuance of this individual permit does not prohibivihe Director from reopening and modifying the individual permit, revoking and reissuing the individual permit, or terminating the individual permit as allowed by the laws, rules, and regulations contained in.Title 40, Code of Federal Regulations, Parts 122 and 123; Title 15A of the North Carolina Administrative Code, Subchapter 2H .0100; and North Carolina General Statute 143-215.1 et alA` Permit Actions jf,r The permit may be modified, revoked.and reissued, or terminated for cause. The notification of planned changes or anticipated noncompliance does not stay any individual permit condition. SECTION C: OPERATION AND MAINTENANCE OF POLLUTION CONTROLS 1. Proper Operation and Maintenance The permittee shall at all times properly operate and maintain all facilities and systems of treatment and control (and related appurtenances) which are installed or used by the permittee to achieve compliance with the conditions of this individual permit. Proper operation and maintenance also includes adequate laboratory controls and appropriate quality assurance procedures. This provision requires the operation of back-up or.auxiliary facilities or similar systems which are installed by a permittee only when the operation is necessary to achieve compliance with the conditions of this individual permit. Need to Halt or Reduce Not a Defense` It shall not be a defense for a permittee in an enforcement action that it would have been necessary to halt or reduce the permitted activity in order to maintain compliance with the condition of this individual permit. Bypassing of Stormwater Control Facilities Bypass is prohibited and the Director may take enforcement action against a permittee for bypass unless: a. Bypass was unavoidable to prevent loss of life, personal injury or severe property damage; and Part III Page 4 of 8 Permit No. NCS000350 b. There were no feasible alternatives to the bypass, such as the use of auxiliary control facilities, retention of stormwater or maintenance during normal periods of equipment downtime or dry weather. This condition is not satisfied if adequate backup controls should have been installed in the exercise of reasonable engineering judgment to prevent a bypass which occurred during normal periods of equipment downtime or preventive maintenance; and The permittee submitted notices as required under, Part III, Section E of this permit. If the Director determines that it will meet the three conditions listed above, the Director may approve an anticipated bypass after considering its adverse effects. SECTION D: MONITORING AND RECORDS Representative Samplinu Samples collected and measurements taken, as required Jier6in, shall 66Uiaracteristic of the volume and nature of the permitted discharge. Analytical sampling,shall;be performed during a representative storm event. Samples shall betaken on a day and time that'js,chi racteristic of the discharge. All samples shall be taken before the discharge joins or is diluted by any th'er§waste stream, body of water, or substance. Monitoring points as specified in this permit shall notb;YUianged without notification to and approval of the Director. 2. Recording Results s... For each measurement, sample,,lnsp 6t on or;'maintenance activity performed or collected pursuant to the requirements of this individual permit epermittee shall record the following information: r a. The date, exact place, and tuCeof sampling, measurements, inspection or maintenance activity; b. The individual(s)`ivho performed the sampling, measurements, inspection or maintenance activity; c. The date(s) analyses were performed; d. The individual(s) who'performed the analyses;' e. The analytical techniques or methods used; and f. The results of such analyses. 3. Flow Measurement Where required, appropriate flow measurement devices and methods consistent with accepted scientific practices shall be selected and used to ensure the accuracy and reliability of measurements of the volume of monitored discharges. 4. Test Procedures Test procedures for the analysis of pollutants shall conform to the EMC regulations published pursuant to NCGS 143-215.63 et. seq, the Water and Air Quality Reporting Acts, and to regulations published pursuant to Section 304(g), 33 USC 1314, of the Federal Water Pollution Control Act, as Amended, and Regulation 40 CFR 136. Part III Page 5 of 8 Permit No. NCS000350 To meet the intent of the monitoring required by this individual permit, all test procedures must produce minimum detection and reporting levels and all data generated must be reported down to the minimum detection or lower reporting level of the procedure. 5. Representative Outfall If a facility has multiple discharge locations with substantially identical stormwater discharges that are required to be sampled, the permittee may petition the Director for representative outfall status. If it is established that the stormwater discharges are substantially identical and the permittee is granted representative outfall status, then sampling requirements may be performed at a reduced number of outfalls. Records Retention ^• r Visual monitoring shall be documented and records maintained at theffacility along with the Stormwater Pollution Prevention Plan. Copies of analytical monitoring results,shall also be maintained on -site.. Ttie permittee shall retain records of all monitoring information, includmg all calibration and maintenance records and all original strip chart recordings for continuous monitoring instrumentation, and"c6pies of all reports required by this individual permit for a period of at least 5 y ars from the date of the sample, measurement, report or application. This period may be�exiehded by request of the Director at any time. Inspection and Entry, The permittee shall allow the Director, or an authorized representative (including an authorized contractor acting as a representative of the Director), in ^case of a facility which discharges through a municipal separate storm sewer system,; an authorized representative of a municipal operator or the separate storm sewer system receiving the di charge, upon thepresentationof credentials and other documents as may be required by law, to; a. Enter -upon the permittee's premises where a regulated facility or activity is located or conducted, or where records .must be kept under the conditions of this individual permit; b. Have access to and "copy, at reasonable times, any records that must be kept under the conditions of this individual permit; C. Inspect at reasonable times any facilities, equipment (including monitoring and control equipment), practices, or operations regulated or required under this individual permit; and d. Sample or monitor at reasonable times, for the purposes of assuring individual permit compliance or as otherwise authorized by the Clean Water Act, any substances or parameters at any location. SECTION E: REPORTING REQUIREMENTS Discharge Monitoring Reports Samples analyzed in accordance with the terms of this permit shall be submitted to the Division on Discharge Monitoring Report (DMR) forms provided by the Director. Submittals shall be delivered to the Division no later than 30 days from the date the facility receives the sampling results from the laboratory. When no discharge has occurred from the facility during the report period, the permittee is required to submit a discharge monitoring report within 30 days of the end of the three-month sampling period, giving all required information and indicating "NO FLOW" as per NCAC T15A 02B .0506. Part III Page 6 of 8 Permit No. NCS000350 The permittee shall record the required qualitative monitoring observations on the SDO Qualitative Monitoring Report (QMR) form provided by the Division, and shall retain the completed forms on site. Qualitative monitoring results should not be submitted to the Division, except upon DWQ's specific requirement to do so. Submitting_ Reports Duplicate signed copies of all reports required herein, shall be submitted to the following address: • ti Division of Water Quality Surface Water Protection Section ATTENTION: Central Files. 1617 Mail Service Center Raleigh, North Carolina 27699-1617 `- In addition, a separate signed Annual Summary DMR_ copyAshall be submitted to the permittee's DWQ Regional Office (RO) by March 1 of each year".g 3. Availability of ReportsRYIL�� 4 Except for data determined to be confidential undeilNCGS IM15.3(a)(2) or Section 308 of the Federal Act, 33 USC 1318, all reports prepared in accor"dance with the terms shall be available for public inspection at the offices of the Division of Water Quality A q required by the Act, analytical data shall not be considered confidential. Knowingly maki g`any`false,statement on any such report may result in the imposition of criminal penalties as provided fOr`inJR 143-215.68 or in Section 309 of the Federal Act. Non-Stormwater Discharges If the storm event.monitored'in accordance with this individual permit coincides with a non-stormwater discharge, the permittee shall separately monitor all parameters as required under the non-stormwater R'm% '�'4 discharge permit and proiii' this -information with the stormwater discharge monitoring report. Planned Changes The permittee shall give notice to the Director as soon as possible of any planned changes at the permitted facility which could significantly alter the nature or quantity of pollutants discharged. This notification requirement includes pollutants which are not specifically listed in the individual permit or subject to notification requirements under 40 CFR Part 122.42 (a). Anticipated Noncompliance The permittee shall give notice to the Director as soon as possible of any planned changes at the permitted facility which may result in noncompliance with the individual permit requirements. Bypass a.•, �., Anticipated bypass. If the permittee knows in advance of the need for a bypass, it shall submit prior notice, if possible at least ten days before the date of the bypass; including an evaluation of ,the anticipated quality and affect of the bypass. b. Unanticipated bypass. The permittee shall submit notice within 24 hours of becoming aware of an unanticipated bypass. Part III Page 7 of 8 Permit No. NCS000350 8, 9 10 Twenty-four Hour Reporting The permittee shall report to the central office or the appropriate regional office any noncompliance which may endanger health or the environment. Any information shall be provided orally within 24 hours from the time the permittee became aware of the circumstances. A written submission. shall also be provided within 5 days of the time the permittee become's aware of the circumstances. The written submission shall contain a description of the noncompliance, and its causes; the period of noncompliance, including, exact dates and times, and if the noncompliance has not been corrected, the anticipated time compliance is expected to continue; and steps taken or planned to reduce, eliminate, and prevent reoccurrence of the noncompliance. The Director may waive the written report on a case -by -case basis if the oral report has been received within 24 hours. Other Noncompliance f The permittee shall report all instances of noncompliance not reported under 24 hour reporting at the time monitoring reports are submitted.dj: li� y yl J Other Information Where the permittee becomes aware that it failed to submit any relevant facts in an application for an individual permit or in any'report to the Director�it shall promptly submit such facts or information. Part III Page 8 of 8 t , ` NCS000350 PART IV LIMITATIONS REOPENER This individual permit shall be modified or alternatively, revoked and reissued, to comply with any applicable effluent guideline or water quality standard issued or approved under Sections 302(b) (2) (c), and (d), 304(b) (2) and 307(a) of the Clean Water Act, if the effluent guideline or water quality standard so issued or approved: a. Contains different conditions or is otherwise more stringent than any effluent limitation in the individual permit; or b. Controls any pollutant not limited in the individual permit. The individual permit -as modified or reissued under this paragraph'.shall also contain any other requirements in the Act then applicable. ff PART V ADMINIISTERING AND The permittee must pay the administering and by the Division. Failure to pay the feein,time this Division to initiate action to revoke-&'Jin 2. 4 Act See Clean Water Act. CE MONITORING FEE Coring fee within 30 (thirty) days after being billed rdance with 15A NCAC 2H .0105(b)(4) may cause DEFINITIONS Arithmetic Mean The arithmetic mean of any set of values is the summation of the individual values divided by the number. of individual values. Allowable Non-Stormwater Discharges This permit regulates stormwater discharges. Non-stormwater discharges which shall be allowed in the stormwater conveyance system are: (a) All other discharges that are authorized by a non-stormwater NPDES permit. (b) Uncontaminated groundwater, foundation drains, air -conditioner condensate without added chemicals, springs, discharges of uncontaminated potable water, waterline and fire hydrant flushings, water from footing drains, flows from riparian habitats and wetlands. (c) Discharges resulting from fire -fighting or fire -fighting training. Best Management Practices BMPs) Measures or practices used to reduce the amount of pollution entering surface waters. BMPs may take the form of a process, activity, or physical structure. Parts IV, V and VI Page 1 of 5 b ' Permit No. NCS000350 5. Bypass A bypass is the known diversion of stormwater from any portion of a stormwater control facility including the collection system, which is not a designed or established operating mode for the facility. 6. Bulk Storage „of Liquid Products Liquid raw materials, manufactured products, waste materials or by-products with a single above ground storage container having a capacity of greater than 660 gallons or with multiple above ground storage containers located in close proximity to each other having a total combined storage capacity of -greater than 1,320 gallons. 7. Clean Water Act 01 The Federal Water Pollution Control Act, also known as the Clean Water'Act (CWA), as amended, 33 USC 1251, et. seq. „% '4_p S. Division or DWQ The Division of Water Quality, Department of Environment and'Natural Resources. 9. Director 1 The Director of the Division of Water, Quality, 11i" rmit issuing authority _ �'N!� 10. EMC The North Carolina Environmental Management Commission. .11. Grab Sample An individual sample collected instantaneously. Grab samples that will be directly analyzed or qualitatively monitored must be taken within the first 30 minutes of discharge. 12. Hazardous Substance Any substance designated under 40 CFR Part 116 pursuant to Section 311 of the Clean Water Act. 13. Landfill A disposal facility or part of a disposal facility where waste is placed in or on land and which is not a land treatment facility, a surface impoundment, an injection well, a hazardous waste long-term storage facility or a surface storage facility. I, I 14. Municipal Separatc Storm Sewer S sv tern A stormwater collection system within an incorporated area of local self-government such as a city or town. 15. No Exposure A condition of no exposure means that all industrial materials and activities are protected by a storm resistant shelter or acceptable storage containers to prevent exposure to rain, snow, snowmelt, or runoff. Industrial materials or activities include, but are not limited to, material handling equipment or activities, Part VI Page 2 of 5 Pages Permit No. NCS000350 16 17 18 19 industrial machinery, raw materials, intermediate products, by-products, final products, or waste products. DWQ may grant a No Exposure Exclusion from NPDES Stormwater Permitting requirements only if a facility complies with the terms and conditions described in 40 CFR § 122.26(g). Overburden Any material of any nature, consolidated or unconsolidated, that overlies a mineral deposit, excluding topsoil or similar naturally -occurring surface materials that are not disturbed by mining operations. Permittee The owner or operator issued a permit pursuant to this individual permit. Point Source Discharge of Stormwater Any discernible, confined and discrete conveyance ditch, channel, tunnel, conduit, well, or discrete fis: waters of the state. Representative Storm Event A storm event that measures greater than 0.1 storm event measuring greater than 0.1 inch( hours of no precipitation. For examplb,9if4t stops, a sample may be collected'if a'rairi prc ly limited to, any pipe, is or may be discharged to 'rainfall and that is preceded by at least 72 hours in which no used. A single storm -event may contain up to 10 consecutive !,hours without producing any collectable discharge, and then discharge begins again within the next 10 hours. 20. Representative Outfall Status When it is established thatH the discharge,of stormwat6r runoff from a single outfall is representative of the � n discharges at multiple outfalls, the D:WQ may grant representative outfall status. Representative outfall status allows the permittee,tolverfartm analytical monitoring at a reduced number ofoutfalls. sr . ,: 21. Rinse Water Discharge The discharge of rinse water from equipment cleaning areas associated with industrial activity. Rinse waters from vehicle and equipment cleaning areas are process wastewaters and do not include washwaters utilizing any type of detergent or cleaning agent. 22. Secondary Containment Spill containment for the contents of the single largest tank within the containment structure plus sufficient freeboard to allow for the 25-year, 24-hour storm event. 23. Section 313 Water Priority Chemical A chemical or chemical category which: Is listed in 40 CFR 372.65 pursuant to Section 313 of Title III of the Superfund Amendments and Reauthorization Act (SARA) of 1986, also titled the Emergency Planning and Community Right - to -Know Act of 1986; b. Is present at or above,threshold levels at -a facility subject to SARA Title III, Section 313 reporting requirements; and C. That meets at least one of the following criteria: Part VI Page 3 of 5 Pages Permit No. NCS000350 (1) Is listed in Appendix D of 40 CFR part 122 on Table 11(organic priority pollutants), Table III (certain metals, cyanides, and phenols), or Table IV (certain toxic pollutants and hazardous substances); (2) Is listed as a hazardous substance pursuant to section 311(b)(2)(A) of the CWA at 40 CFR 116.4; or (3) , Is a pollutant for which EPA has published.,acute or chronic water quality criteria. 24, Severe Property Damage wy Means substantial physical damage to property, damage to the control facilities which causes them to become inoperable, or substantial and permanent loss of natural resources which can reasonably be expected to occur in the absence of a bypass. Severe property damage does not mean economic loss caused by delays in production. ' ' y "A , . 25. Significant Materials Includes, but is not limited to: raw materials; fuels; materials such as solvents, detergents, and plastic .t4 •4:e pellets; finished materials such as metallic products; -raw materials used in food processing or production; hazardous substances designated under section;101(.14)'6f,CERCLA; any chemical the facility is required to report pursuant to section 313 of -Title III of SARA; fetrtilizers; pesticides; and waste products such as ashes, slag and'sludge that have the potential to be,released with stormwaterdischarges. 26. Significant Spills Includes, but is not limited to: releases of oil or hazardous substances in excess of reportable quantities under section 31 I -of -the Clean Water pc{(Ref: 40 CFR 110.10 and CFR 117.21) orsection 102 of CERCLA (Ref: 40 CFR 302.4). 27. Stormwater Runoff The flow of water which results from precipitation and which occurs immediately following rainfall or as a result of snowmelt. 28. Stormwater Associated with Industrial Activity The discharge from any point source which is used for collecting and conveying stormwater and which is directly related to manufacturing, processing or raw material storage areas at an industrial site. Facilities considered to be engaged in "industrial activities" include those activities defined in 40 CFR 122.26(b)(14). The term does not include'discharges from facilities or activities excluded from the NPDES program. 29. Stormwater Pollution Prevention Plan A comprehensive site -specific plan which details measures and practices to reduce stormwater pollution and is based on an evaluation of the pollution potential of the site. 30. Ten Year Design Storm e. ' 4 _ t �! The maximum 24 hour precipitation event expected to be equaled or exceeded on the average'6nce in ten years. Design storm information can be found in the State of North Carolina Erosion and Sediment Control Planning and Design Manual. Part VI Page 4 of 5 Pages Permit No. NCSoo 0350 31. Total Flow The flow corresponding to the time period over which the entire storm event occurs. Total flow shall be either; (a) measured continuously, (b) calculated based on the amount of area draining to the outfall, the amount of built -upon (impervious) area, and the total amount of rainfall, or (c) estimated by the measurement of flow at 20 minute intervals during the rainfall event. 32. Total Maximum Daily Load (TMDL) A TMDL is a calculation of the maximum amount of a pollutant that a waterbody can receive and still meet water quality standards, and an allocation of that amount to the pollutant's sources. A TMDL is a detailed water quality assessment that provides the scientific foundation for an -implementation plan. The implementation plan outlines the steps necessary to reduce pollutant loads in a certain body of water to restore apd maintain water quality standards in all seasons TheClean Water Act, Section 303, establishes the water quality standards and TMDL programs. UPS",_ 33, Toxic Pollutant Any pollutant listed as toxic under Section 307(a)(I).ofjthe C1ean)Water Act. 34. LRa!Lt ti Means an exceptional incident in which there is,unmtentional and temporary noncompliance with technology based permit effluent�limit&i ns because of factors beyond the reasonable control of the .� � .�,�� permittee. An upset does not include noncompliance to the extent caused by operational error, improperly designed treatment or control facilities; inadequate treatment or control facilities, lack of preventive �rtt;A maintenance, or careless or improper operation. I 35. Vehicle Maintenance _Act tAlf Vehicle rehabilitation, mechanical repairs, painting, fueling, lubrication, vehicle cleaning operations, or airport deicing operations. 36. Visible Sedimentation Solid particulate matter, both mineral and organic, that has been or is being transported by water, air, gravity, or ice from its site of origin which can be seen with -the unaided eye. 37. - 25-year. 24 hour storm event The maximum 24-hour precipitation event expected to be equaled or exceeded, on the average, once in 25 years. Part VI Page 5 of 5 Pages N( S000350 AT;` , . . NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary STAFF REVIEW AND EVALUATION NPDES Stormwater Permit Facility Name: Cogentrix, Edgecombe Genco, LLC, P.O. Box 370, Battleboro, NC 27809 NPDES Permit Number: NCS000350 Facility Location: 6358 Old Battleboro Road, Battleboro, NC 27809 (Edgecombe.County) Type of Activity: Coal Fired Power Plant SIC Code (if applicable): 4931 or 4911 Receiving Streams: See Figure 1 River Basin: Tar -Pamlico River Basin, Sub -basin 03-03-02 Stream Classification: UT to Beech Branch: C, N5W Proposed Permit Requirements: See attached draft permit. Monitoring Data: See Table 1 Response Requested by (Date): May 30, 2010 Central Office Staff Contact: Return to: Jennifer Jones, (919) 807-6379 Special issues: Issue Rating.Scale:.1(easy) to 10(hard)„, Compliance history 3 Benchmark exceedance 5 Location (TMDL, T&E species, etc) 2 Other Challenges: Monitoring of pond 3 Difficulty Rating: 13/40 Special Issues Explanation: • Not monitoring sw pond. May have sediment issues or illicit WW discharge in it. Description of Onsite Activities: • Coal fired power plant for electric generation. All site stormwater flows into a detention pond and then is discharged via one stormwater outfall at the southern end of the site (SDO 001). Also has FGD wastewater system and reverse osmosis for WW. Documents Reviewed: ' Page] of 8 #Rr NCS000350 History: NPDES Stormwater Permit Application Materials National Heritage Program (NHP) Threatened and Endangered Species Database SPU File Central Files EPA Sector -Specific Permit, 2008 303(d) List, 2008 draft, 2006 final 2008 (draft) Yadkin Pee -Dee Basinwide Plan Inspection reports from RRO TRI database Date permit first issued:1996 Date permit re -issued: 5/1/2002-4/30/2007 Date permittee submitted renewal application: 10/25/2006 Page 2of8 1io1jp:)oj AJ!113PA r" t w►.��►a►wr �+� � ,yf+ Ism slim •.i.•` i S JO C Q&d (ulseg aanlld wed-ael7 ZO-CO-EO :Urseg-qrr MSN r3 :Ssen weaAS 4wej8 4-w8 C4 lul :uuea.rjS 6ulnlaD&8 Nwoaabpg .A4unoa M ,.91 ,K oLL :0PNIbu l N r,; t rZO o9£ :BPMnel 3N 1oaogajjje9 IZS'8i: T are�S dpid S �' `� { L'ri ♦ � r n , �t I � ti~. tJ+.7A.,,,..1i �. �r'��.r r .yam '•►..{ IF ,, y, � t - "�x� ,i: 4h 1 ! i� .{r.5vs- [-� �y_`�a, �a�: `r ti 1,� r !li I r rg � � � •` �; �y �, .-' . ,i', v�fF Jl t •'�a- '! 'r t ti~t h vi^t C r 4. '� 'T- a.;n �''1 :s.-i, `..: jI { f • � 4 rI 7Z,fir' Ir r, �"L�'ti..•9 i' � 1 x f r � 1__.• r. 'I ' t,�°.- tarty h } ;'.^,\ t�'..4r�,� .. ` �_j. r•s�•=' —�.iC i 'r�� � F�.. � � y ,� y{ 1 � � 1 �� • fir " ti [ � � v-• l; % •� \ ,d[r"S. tr I � '�f � j f' :, I �'�' �� 1 ''y \ ' rt A'� ti"�"`�rr .� � y.:. � q.. •. i"5, ._ � ' r- ••' ` 'r �r��,1 i:l I. Ir 4 �r � tl i � \ ti.. ^.`, ter*"" ' .r •,x r"� ,,,�tir c�t,,w',j• qs T.or�C � n.. �,.arar 1 .•(' � a ' `' 4 Y r. �' i tit �" �,. 4"" � r �"� r, I� s '.` s . -'7 V � �"''. y.'N, +4� ''"' �i� _`Ltr ,,, I�+- •tom—'f,`i',}N ( `g� :.k � 5.+4 � Y 1 • t`!r i ' � % "+1�- •Lh _�'{•/, .4''I I QS/.,,. •. '4 r �'} 4 •--., ` •S tzy r." , # s r�'� el y I ,.r �•k '{r. I mo o'" �� :S �rl t`• 4 t14. its. ! iri jj 't 1t -i I•{i r� r� +�, 5�.• 11 `•y'f�•wyj� ��I:31� 'l�:�r •� 11a �4'r l��' } ''I I M,k ���...�. -.,y �i'z �. i� � y '/ c��,r f. �,�� : , �t�,_ 'r 1 - �` �>� ar. tip• r.' _- IL.T :` L W r -�� .- } � ! r '.'..•.'�ia• y4 i. .`A �: /✓ r 11 L h �' �� ..`ti+,h• �!V-.Wi_y r•'-.�F } _ ..L x'I �IJ��% L r} +;,,�, 'Fi f i''f'' xr't r �L I tt i. . y � �'}•,�c [ .. rRq', .11 'A� '.- "w� "W+,,,"`r,� y' ` t_ • i .t. �`+;��`l f•' t �1 r yg.,�� l r 9 . ��7 rOaU2� Q�2bp { . Y `S•� '� +t� 4 �'-�', ��ti `�''� I� � '1~ �?. !�r �`r '•••rt�'a'.� 1�1r.1 ���� - I ! ''��I. x!s o � r ''i „2� - 4 t � } � h� 1 r 1 �� 1 I ��-"is4�rr =, a if •� �i' 'k• ~ +� r [ ??i�F, rL?t �' I • �-#; �� {�4'j j1 a.i � c - �''E +'' 'v �.4 is r+ 4 .ti..r R' /)},^ //�� ,,.. ,r1jy it ` r'rir�'S i 1 s`�yf f Y• s L f,i• -4.4 k } 4 I I t y\ i �44• I I £t r 4'� 1� U� " -',.%,i���'r � � .�j� �•//n� V 4 �: I � _ I,.. �' ' f ��ar� ¢ x_ i _LY ems' ` 1`. ';'�}'� {;i.r'L3 {� \11�. .. ,,t`�.�t ~4 ��✓.% t-�.f ,''I' ,�,i {(�'h��,MLI�r f%'r. � '� �i:' ` ����rr�� i r4y i i.l� �" f.x 'l'• �' r`� ^ ...1 fir. ,t`'.,;,i^ 9 , ''S ''�: ,t r ri^tj i+( r �'• •'yl rr -••a+ ti' fss �..F r•.'- Tf`•'`..-•�.!n ''_ ,z' L,\ 1 �Rw� r •4}� �' r \'\ +}I ` � t:, f ti k�^ I �"e'" • i N r s�' r �- 1'i� : 7^�:�^�r"ye"'"r-L `•\ "' y+• 'p `l. 1_ ! I",e.;5�4 \ 1 r A.'' �~ -"r 1 k f r I ,t rr # YI' . k 5 ✓,'t.a,. Yz y,rs ,,, �4 E rt- „P:wr_-^-• 7; �� �` �• l��I �..�.. "r:l . • J`•�'J� 'r'4 I- �'`4f T'j¢i•` nerd;! V r'� 1 ` _ ¢•J, r ` ; i �z , '� •:�R,r a" a , ,4r• es ,.rti. y, 14 f e4•_fyAA" I � l � . � x'1 ''S_ z,;Mti w1Y "l .PIS:sl r 61 'j d•...�'•rd' j r �� "'e�' ` 's t" [� � �z" .t�, � �""`t r . , f.. t t,'• r� • •�, "-• n`� �:yy- � , . ' �f � s � . r x 5, s ' r �": n:, i 9 - e'f 'rh�t fl .`i1- `� ,, ,pii... • o♦ � 'i ti.sk,, a ti , •�� /IA. R, s l~s�t .54 • 1A1, r11 ��'•^r I 1 l�� 5�7�rt1[ 1 ,\1 -v:_. : IeZ.I. 1 j. wµ� •lr?.•. .>? MT�rI Y,:S:. 4,t,.. •, ?t 1 'rJ i7CT t4~ ,4 i 1:1 �r 1' S1 �. ♦ , r•r '',. . xi! aj� r .h. `w t `•"-"'' f "e '"4 r •`. I-i', ..�. .,•. '1�_ r L 01,.E `' 1 P #4i- 14 • �, / �\ t i%%�' •ri,•y r F I- SY rtr 1 'r• '� 4 h 4 ,� -!. `_.,I, I ' L _ � • +yi S • • 'r�� �y• t ;'f�'S lE sY xi i'- s:9 _ r ° • ilr _�� ••" a (( r X. r la 1�1 a „`•r���..:,�'•9Y..r »;tc .'i�;?c".Wr -�--. �ti4Y_. -....._... � �.}. �_. _✓ ;� r" ��-h�I"I '-- ` - ---.L1.'� A31IEaeA }o deW :T ainSIA QS£Oti�05�N NCS000350 Central Office Review Summary: 1. Owner's Other Permits: • NPDES Wastewater Permit: NCO077437 — Ltr of violation/warning on 5/1/2008 • FRS 110000604221 • CAA NEI NE143935 / #3706500146 State NOV issued for Air Permit 7/10/2008. • EP313 TRI 27809CGNTRRTE2S EDGECOMB GENCO LLC 6358 OLD BATTLEBORO RD BATTLEBORO NC 27809 2. General Observations: o One stormwater outfall (SDO 001). According to RRO reports, qualitative monitoring is currently being recorded but no analytical monitoring was being reported from $DO 001. SDO 001 was sampled by the RRO on 5/20/2009 and it was found that Al was 510 ug/l and Fe was 420 ug/l. 0 5/20/2009 Sampling revealed concerns with SW: 1. Al: 510 ug/l, Ar: 7 ug/I, Boron: 65 ug/I, and Zinc 21 ug/I 2. However none appeared to have issues with stormwater OVER benchmark at that date. o Wastewater has issues with Zinc, sulfate, Boron, Cu, & Mo, 3. Impairment: o Not on 303D list and does not have TMDL. it is in Tar -Pam NSW however. 4. Threatened and Endangered: o No T&E species appear to be present in the area. S. Location: o South of Battleboro. Permittee needs to know that the facility discharges to Beech Broach not Beech Creek. Viewed satellite image on Google Maps. 6. Industrial Chances Since Previous Permit: o WW files indicated changed from wet to dry ash facility. 7. Analytical Monitoring Notes: o No analytical monitoring of SW outfall for SDO 1 was available to RRO on their inspection in May of 2009. RRO told the facility that they should be monitoring for analytical parameters at that time. o RRO stated in their EPA/WW permit compliance evaluation report "FGD system evaporates wet FGD wastewater — this water is sometimes exposed to the driveway (stormwater drains) where it is located (depending on evaporation rates/water levels) and the solids are removed and land applied by full circle solns as stated above. The facility removes solids from the WW basins and the solids are hauled off to the Sampson County Landfill twice per year." o RRO noted in stormwater evaluation on 5/20/09 "continuous discharging stormwater pond requires sampling. No analytical monitoring data available. Recommended measuring sediment in SW pond." Also "Plant refers to SDO 001, DWQ refers to it as SDO 005". o In 7/3/08 inspection permittee stated again that they did not need to sample based on pond discharge times (only in response to 10-year storm) however it was discharging at the time of inspection though the overflow pipe, it had not rained in quite some time prior to inspection. "This strongly indicates one or more unidentified, unauthorized, illicit wastewater discharges through the stormwater detention pond." RRO told them to ID illicit discharges. NOV was issued for no qualitative discarges P but deleted because in 5'h year of permit and permit did not require analytical monitoring at that time. [ �aUS CG's C4ex, r- r a aoh 15 4L r.4- Page 4of8 qr I 1 J + q o v r, Gc w o-T r , �� r�c� j,,4_ s di 5��a.r�. rtiJc c�ur��n� SLy�e Vi! s!'� o f1 4.2./n . I) Pa".."e 0 �220 NCS000350 o Although RRO states that there is only 1 SW outfali (001), there appear to be at least 4 others (#2-5)� SWO05 is near coal pile and may be of concern. $ e e in o e G e 6 w ° a Previous permit's (2002) analytical monitoring was 1. TSS, COD, Total Rainfall, Event Duration, Total Flow. All sampled annually on year 1, 2, 3, quarterly on year 4. 2. No Benchmarks or cutoff concentrations were included in the permit. 8. Qualitative MonitorinjR Notes. o Notes from 7/3/08 inspection report state: "Qualitative monitoring is being done more often than required. However permittee must ensure that even though its lone more often than needed, it still must be done at least twice pe duringthe timeframes specified in the permit. o There was a summary of qualitative monitoring in the application (2006) but thered'§"e'Otp no C� stormwater dates associated with them. Describes 004 and 005 as having possible clarity or turbidity issues, and 004 as having odor issues. - Table 1: Analytical Monitoring 5 ct e V t 6 It 0 r\ 5 0 ire c ci rrn �►� GC7 n -Pt .ii' KV-` s h IL+ -f � It r- e- o_ r e cl a S irrn Page 5 of 8 �a[�L�IIIIL�317 ,.Revised Permit Recommendations: Analytical Monitoring: 1. Monitoring: a. Adding parameters (Quarterly Monitoring): i. Semi-annual monitoring for 13 priority metals (Ag, As, Be, Cd, Cr, Cu, Hg, Ni, Pb, Sb, Se, TI, Zn) + Al & B, with benchmarks where available (per conversations with RTI's Robert Scheuster, Duke University Professor Dr. Avner Vengosh, Regional Office Observations and new SPU monitoring plan for Coal-fired power plants) . See Attached Monitoring for Power Plant NPDES Stormwater Permit Renewals in 2009. ii. Semi-annual Hg monitoring with more sensitive method 1631E. iii. Semi-annual monitoring for sulfates, and O&G, and pH b. Keeping monitoring for COD, TSS in the permit (now semi-annual). 2. All analytical monitoring has been set to semi-annually during a representative storm event as defined in Part II Section B. The permittee must also document the total precipitation for each event. if no discharge occurs during the sampling period, the permittee must submit a monitoring report indicating "No Flow" within 30 days of the end of the six-month sampling period. Additionally, samples must be taken a minimum of 60 days apart, as specified in Table 2. 3. Benchmarks for analytical monitoring have been added to this draft permit. Exceedances of benchmark values require the permittee to increase monitoring, increase management actions, increase record keeping, and/or install stormwater Best Management Practices (BMPs) in a tiered program. If the sampling results are above a benchmark value, or outside of the benchmark range, for any parameter at any outfall then the facility shall follow the Tier 1 guidelines which require a facility inspection within two weeks and implementation of a mitigation plan within two months. If during the term of this permit, the sampling results are above the benchmark values, or outside of the benchmark range, for any specific parameter at a specific discharge outfall three times in a row (consecutive), then the facility shall follow the Tier 2 guidelines which require a repetition of the steps listed for Tier 1 and also immediately institute monthly monitoring for all parameters at every outfall where a sampling result exceeded the benchmark value for two consecutive samples. 4. The permittee is required to collect all of the analytical and qualitative monitoring samples during representative storm events as defined in Part II Section B. Qualitative monitoring is required regardless of representative outfall status. 5. The permittee is responsible for all monitoring until the renewal permit is issued. See Footnote 1 of Tables 1, 4,and 5. 6. The flow reporting requirement has been removed per DWQ revised strategy. (The total rainfall parameter is in this permit, however.) 7. Vehicle maintenance monitoring has been revised to semi-annually in order to coincide with analytical and qualitative monitoring. Other Proposed Changes to the Previous Permit: 1. Additional guidance is provided about the Site Plan requirements. The site map must now identify if the receiving stream is impaired and if it has a TMDL established. It must also describe potential pollutants in each outfall. The map requirements are stated more explicitly. And, the site plan must contain a list of significant spills that have occurred in the past three years and also must certify that the outfalls have been inspected to ensure that they do not contain non-stormwater discharges. Additional information is provided in Part II Section A. - 2. Additional requirements for the Stormwater Management Plan have been specified in Part II Section A. More' details regarding secondary containment are provided." 3. Additional requirements for the Stormwater Pollution Prevention Plan have been specified in Part-ll Section A. �The.plan must also be updated annually to include a list of significant spills and to certify that the outfalls do not contain non-stormwater discharges. 4. The facility must now implement a semi-annual Facility Inspection Program of the site's stormwater Page 6 of 8 NUS000350 management controls as specified in Part II Section A. Information regarding the No Exposure Exclusion has been added to this draft permit. if industrial materials and activities are not exposed to precipitation or runoff as described in 40 CFR §122.26(g), the facility may qualify for a No Exposure Exclusion from NPDES stormwater discharge permit requirements. Additional information is provided in Part I Section A. Discussions with permittee: Not needed as RRQ had recently been out there, we had correspondence, and we have the Monitoring for Power Plant NPDES Stormwater Permit Renewals in 2009. . Page 7 of 8 NCS000350 Recommendations: Based on the documents reviewed, the application information submitted on October 25, 2006 sufficient to issue an Individual Stormwater Permit. Prepared by (Signature) Date -,-3 1-0 (0 Stormwater Permitting Unit Supervi r `Date gS17,6 16 for B ey Benrut Concurrence by Regional Office� A�� Date RO Water Quality Supervisor Date Z� Page 8 of 8 Required Sampling Range Sample Date Total Flow (MGD) Precipitat ion (in) Duration (hours) TSS COD Benchma rk: 100 m IL Benchma rk: 120 m IL Outfall 1 11 I212009 0.79 4.8 15 3/3/2010 0.55 12 22 3/5/2008 1.11 25 26 10/25/2007 1.26 13 <10 4/16/20071 1 1.5 1 1 14 26 E 1 3/12/20071 1na 1 1 3 1 10 Over Current Benchmark Data Not Collected ' Monitoring Strategy for Power Plant NPDES Stormwater Permit Renewals in 2009 Renewal Permit Monitoring: In recent years, the Stormwater Permitting Unit has recognized the complex issues associated with coal -burning power plants and the increased attention on coal ash storage, use, and disposal at these sites. Data on stormwater discharges from these plant sites is limited because the focus has traditionally been on wastewater. Regions have also voiced concern about potential contamination from metals in stormwater discharges associated with the activities at these sites. After researching constituents these activities or materials may introduce to the power plant property (and with them potential for stormwater pollution), the Unit formulated a strategy for these renewal permits: • Semi-annual monitoring for: 13 priority metals (Ag, As, Be, Cd, Cr. Cu, Hg*,. Nip- Pb, Sb,, Se, Tl, Zn) + Al & B, with benchmarks where available: La s's: Draft RTI Study ('Human and Ecological Risk Assessment of Coal Combustion Wastes; RTI, August 2007) and discussions with Robert Schreusdale of RTI suggest these metals may signal contamination problems. SPU also discussed contaminants with Duke University researcher, Dr. Avner Vengosh, who researched the TVA ash pond spill that occurred in Dec 2008 in Kingston, TN (Mtg with SPU on May ¢, 2009). In addition, RRO/DWQ has sampled discharges from cogeneration plants in the FRO area and flagged metals of concern. Overall, we have very little data with which to characterize stormwater discharges from this industry, but we know there is a concern and need for better understanding about possible stormwater pollution from the activities here. + *Semi-annual Hg monitoring with more sensitive method 1631E but no benchmark (or obligation to monitor monthly in Tier 2). (FYI - Cost of clean mercury method around $100.) Basis: Power plants area potential major source of mercury, and although some Hg may be regional, there is a risk that significant quantities come from the activities at the plant itself. While wastewater permit limits are calculated based on low stream flow and high wastewater effluent flow conditions —and sometimes do not warrant the lower -detection method—stormwater contributions vary broadly and do not change the bio-accumulative nature of methyl -mercury. SPU recognizes the complexity of regional air transport and deposition, as well as the cost and resources involved in clean mercury sampling protocol, and therefore will exempt Hg from monthly monitoring in the tier structure. However, if mercury data suggest a problem driven by sources or activities at the plant, DWQ should investigate further and could require additional monitoring in the future. Semi-annual monitoring for COD, TSS, pH, sulfates, and O&G. Basis: conventional pollutants associated with types of activities here. Note -include provision to allow pH values below benchmark if facility can document rainfall pH is as low or lower at time of sampling. 1 Last revised 9/22/2009 Monitoring Strategy for Power Plant NPDES Stormwater Permit Renewals in 2009 + Requirement to submit annual data summary. to DWQ. B. asls: Consistency with current draft General Permits and to facilitate prompter awareness of monitoring results at the regional office level. include this option for DWQ response to four -benchmark exceedences: "Work with the permittee to develop alternative response strategies." SPU will consider alternative strategies for monthly monitoring in Tier 2, especially in response to benchmark exceedences of parameters like Cu and Zn, and will make efforts to discuss possibilities with permittees during draft permit phase. For example, plants might consider installing bioretention cells for drainage areas where metals are a problem and monitor for effectiveness, in exchange for decreased monitoring frequency and/or no benchmark trigger. We will also consider relieving monitoring if the facility can demonstrate levels are not attributable to, or else not able to be separated from, industrial activities. SPU will work with the regional offices to address situations on a case -by -case basis. Bas15: SPU recognizes the ubiquitousness of copper and zinc, and the low benchmark concentrations for metals like Cd, but we also know activities at power plants can be contributors of these pollutants. SPU feels alternatives to more monitoring can facilitate solutions and that the permit tier structure is flexible enough to relieve the permittee of monitoring when appropriate. + Where coal pile runoff and leachate is not treated and/or permitted under a wastewater permit, examine for need to apply storwmater effluent limits. Federal effluent guidelines apply specifically to the Steam Electric Generating industry, which excludes cogeneration facilities. However, cogeneration plants are similar in many respects, and coal storage and handling activities may even be identical. SPU will consider a tailored approach for certain SDOs based on proximity to coal sources, storage area size, etc. Depending on the size and similarity of the coal storage and handling (and perhaps other factors), the permit writer could decide to (a) apply limits initially, or (b) an arrangement where benchmarks mirroring BPT requirements for coal pile leachate in 40 CFR §423 (TSS of 50 mg/l and pH 6-9 SU) would become limits after two exceedences (i.e., Tier 2 action), or (c) just impose benchmarks. Basis: Federal stormwater effluent limits apply to coal piles atsteam electric generating facilities, similarity of cogeneration plants (and even elsewhere) warrant similar scrutiny. Other states such as Virginia, Ohio, and Georgia have already imposed the same BPT limits on coal pile runoff and leachate at facilities where coal burning for steam electric generation is not necessarily the primary industrial activity. The flexibility for North Carolina to do the same follows that lead and acknowledges the potential for the same pollution problems. Last revised 912212009 y ' ' Monitoring Strategy for Power Plant NPDES Stormwater Permit Renewals in 2009 Relevant E-mail Correspondence: -----Original Message ----- From: Jones, Jennifer M. [mailto:jennifer.jones@ncdenr.gov]- Sent: Monday, May 04, 2009 9:05 AM To: Bethany Georgoulias; Ken Pickle; Cory Larsen; brian.lowther@ncmail.net; Jennifer Jones Cc: Bradley Bennett; 'Robert Patterson'; Mike Randall Subject: RE: Power Plants & SW Permit Strategy Just talked to Robert Schreusdale @ RTI. He said our list of analytes sounds good but we should consider adding Cobalt and Iron. I mentioned the concerns with Iron ubiquitousness but he said that it may be present at such high levels that it's a concern. He suggested background monitoring - I told him the concerns we have with that. -----Original Message ----- From: Hoban, Autumn Sent: Tuesday, July 07, 2009 11:52 AM To: Lawyer, Mike Cc: Brower, Connie; Jones, .Jennifer; Georgoulias, Bethany Subject: Correction on FRO Power Plant Sampling Qualification Mike, Just needed to follow up on e-mail from April 9, 2009. This e-mail is inserted between the number lines below in light blue: I have the lab results from the FRO power plant visits. ***Lumberton NC0058297 outfall 003 - *Arsenic 3.8 ug/L*, *Copper 31 ug/L*, *Nickel 15 ug/L*, Titanium 29 ug/L, and *Zinc 390 ug/L*, *A1 400ug/L* SW1- *Al 4400 ug/L,* *Arsenic 3.6 ug/L*, *Copper 14 ug/L*, *Titanium 220 ug/L*, *Zinc 420 ug/L* Elizabethtown NC0058301 outfall 003 wastewater -*Copper 22 ug/L*, Zinc 20 ug/L outfall 005 SW- Zinc 11 ug/L I bolded possible concerns*, "this data is not adequate for determining compliance." * These samples went to lab the same time their freezer went out, so data is qualified -not the best situation, but for identifying what's there, I think this is relatively accurate. Another sampling event would be needed, especially at Lumberton. Sampling should probably be done at the Progress Energy Plant nearby that has the ash pond. 3 Cast revised 912212009 Monitoring Strategy for Power Plant NPDES Stormwater Permit Renewals in 2009 These two facilities have coal piles, but no ash ponds on site and neither facility has been operating consistently. Neither was operating the day we sampled. If operating expect these would be higher. Just let me know if I can be of assistance. -4 i-i-i-i i i-I FTITE ITF 3- i i 1 01 1 1 1 --1 1 1-1 }_ 1-{ 0 0 1 1 1 1 Connie has so kindly pointed out that the metals sample results would not be effected by the freezer/cooler issues experienced at lab, so my statement about "results not being adequate to determine compliance" is incorrect. Please review the laboratory sections qualifiers by each analyte to determine which analytes were qualified. If you have not received a copy of the results from the lab, I can scan and send the copies that came to RRO. Can you let me know if anyone is evaluating Lumberton Site "SW1 outfall" and "WW Outfall 003" with regards to permit requirements and these sample results. We may want to resample, since some levels in these results seem unusually high, but that's up to FRO. Sorry for the confusion. -----Original Message ----- From: Drew Zurow[mailto:Drew.Zurow@dnr.state.ga.us] Sent: Tuesday, July 28, 2009 8:56 AM To: Georgoulias, Bethany Cc: Larry Hedges Subject: Re: [stormwater] Coal Pile Runoff 5W Effluent Limitations Bethany, Georgia's general industrial stormwater permit has TSS/pH limits for all coal pile runoff, whether or not thethe source is a Steam Electric Generating Plant. This has been the case since our first industrial stormwater permit issuance in 1993. We have not yet seen a good reason to modify our original permit language and exclude facilities that are not Steam Electric Generating Plants from these limits. 4 Last revised 9/22/2009 NCS000350 Recommendatlons: Based'on the documents reviewed, the application information submitted on October 25, 2006 sufficient to issue an Individual Stormwater Permit. Prepared by (Signature) Date 'z3 2� t 0 f Stormwater Permitting Unit Supervi r `` Date for Br4 ey !nrgt' Concurrence by Regional Office Date RO Water Quality Supervisor Regional Office Staff Comments (attach additional pages as necessary) A Page 8 of 8 Date .. - /1 ..,.. era. ,COUN'TY�F:tENUSE' NUNMiR FACEUT'Y: CITY: PERT NUMBER COUNTY: Permit Information that Needs to be Incorporated into Future Permit Revisions; DATE COM.NTS 11311 9 1CDGIECOMBE GENCO, LLC 6358 Old Battleboro Road, Battleboro, North Carolina 27809 September 2, 2010 Point Source Branch Surface Water Protection Section Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 Subject: Delegation of Signature Authority Edgecombe Genco, LLC NPDES Wastewater Permit No. NCO077437 NPDIES Stornmater Permit No. NCS000350 To Whom It May Concern: By notice of this letter, I hereby delegate signatory authority to each of the following individuals for all permit applications, discharge monitoring reports, and other information relating to the operations at Edgecombe Genco, LLC as required by all applicable federal, state, and local envirorvnental agencies specifically with the requirements for signatory authority as specified in 15A NCAC 213.0506. Robert J. Montore Projects General Manager Lauren Billheimer Compliance Manat:er_ In addition, I hereby delegate alternate signatory authority to the following individual for discharge monitoring reports from the Edgecombe Genco, LLC facility. Bill Maiden Plant Manager,T If you have any yueS6U11s rebar'dinb fins Iciicr, JAC-1sC fuel rRx lu colllact Bub 1VIVlliUiC ill 910-777-4095. Sincerely, 1 Warren MacGillivray Cm Vice President`}2. Edgecombe Genco, LLC cc: Raleigh Regional Office, Surface Water Protection Section, 1628 Mail Service Center, Raleigh, NC 27699-1628 Technical Assistance and Certification Unit Bob Montore — Projects General Manager Lauren Billheimer — Compliance Manager Bill Maiden— Plant Manager Tony Halcomb — NAES Division Directot W EPA IDEA Query Results Page 1 of 5 a,;SYktf 3r,r� Enforcement & Compliance History Online (ECHO) Q tr44 PRO" You are here; EPA Home Compliance and Enforcement ECHO Search Data Search Results Detailed Facility Report R6 rt Data f Error JQitirOnary For Public Release • Unrestricted Dissemination Report Generated on 04/23/2010 US Environmental Protection Agency - Office of Enforcement and Compliance Assurance Facility Permits and Identifiers Dmta Dictionary 1i Statute System Source ID Facility Name Street Address City State Zip FRS 1 1QQQ.QQ, 422.1 COGENTRIX OF ROCKY MOUNT RTE. 2 SR 1400 BATTLEBORO NC 27809 CAA AFS 3706500146 EDGECOMBE GENCO LLC 6358 OLD BATTLEBORO BATTLESORO NC 27809 ROAD CAA NEI iVlA3.5. COGENTRIX OF ROCKY NC 27809 MOUNT CAA INEI INE143935 Cogentrix of Rocky Mount NC 27809 CWA PCS NCO077437 Edgecombe Genco LLC 8355 Old Batileboro Rd BATTLEBORO NC 27809 Batsleboro TOWN EP313 ITRI n',7F'090Q.iNTPATE2$ EDGECOMS GENCO LLC 6358 OLD BATTLEBORO RD BATTLEBORO NC 278D9 Facility Characteristics Data Dlcttonary� Statute Source ID Universe Status Areas Permit Expiration Latitude/ Indian Sic NAICS Date Longitude Country? Codes Codes LRT. 110000604221 35.907300 , No •77.598100 Major MACT (SECTION 63 CAA 3706500146 (Fed. Operating NESHAPS), TITLE V NA 4911 Rep.) PERMITS, SIP , PSD , NSPS CWA NCO077437 Minor Active 10/31/2009 35,9781 , 77,7583 No 4931 EP313 27809CGNTRRTE25 36.0378 , NA 4911 221112 -7T 7542 It the CWA permit Is past its expiration date, this normally means that the permitting authority has not yet Issued a new permit. In these situations, the expired permit is normally administratively extended and kept in effect until the new permit is issued. For the RCRA program, activities that contribute to an overall facility status of Active are displayed in parentheses using the acronym HPACS, where H indicates handler activities, P - permitting, A - corrective action, C - converter, and S - state -specific. More information is available in the Data Dictionary. Inspection and Enforcement Summary Data Data i)1 ictionary i Statute Source ID I Insp. Last 05Yrs I Date of Last Inspection I Formal Ent Act Last 05 Yrs I Penalties Last 05 Yrs CAA 3706500146 15 03/10/2009 10 $00 CWA NCO077437 13 05/20/2009 10 $0U F Compliance Monitoring History (05 years ) t Data Dictfonary IStatutel Source ID Isystemll Inspection Type Lead Agency Date Finding http://www.epa-eclio.gov/cgi-bin/get 1cReport.cgi?tool=echo&IDNutnber=110000604221 4/23/2010 EPA IDEA Quety Results Page 2 of 5 CAA 137065,30146 AFS ISTATE CONDUCTED FCEION-SITE State 09/21 CAA 3706500146 AFS TITLE V COMPLIANCE CERTIFICATION State 0112712006 Result -IN COMPLIANCE REVIEW CAA 3706500146 AFS STATE CONDUCTED FCEION-SITE State 09/12t2006 CAA 3706500146 AFS STATE CONDUCTED FCE/ON-SITE State 03/07/2007 CAR 3706500146 AFS TITLE V COMPLIANCE CERTIFICATION State 0712212007 Result -IN COMPLIANCE REVIEW CAA 3706500146 AFS ISTATE CONDUCTED FCEION-SITE State 0111512008 CAA 3706500146 AFS TITLE V COMPLIANCE CERTIFICATION State 0112512008 Result=lN COMPLIANCE REVIEW CAA 3706500146 AFS TITLE V COMPLIANCE CERTIFICATION State 0211712009 Result -IN COMPLIANCE REVIEW CAA 3706500146 AFS STATE CONDUCTED FCElON-SITE $late 03/10/2009 CAA 3706500146 AFS TITLE V COMPLIANCE CERTIFICATION State 0210312010 Result=lN COMPLIANCE REVIEW CWA NCO077437 PCS COMPLIANCE EVAL (NON SAMPLING} JoinU'State Lead 07I2712005 CWA NCO077437 PCS COMPLIANCE EVAL (NON -SAMPLING) State 03108i2007 CWA NCO077437 PCS COMPLIANCE EVAt (NON -SAMPLING) ISlare 0520i2009 Entries in italics are not considered inspections in official counts. Compliance Summary Data Information on the nature of alleged violations is available on the FAO page. .E?uts-Dlttl:lanrt Statute Source ID Current SNCIHPV? Description Currant As Of Otrs in NC (of 12) CAA 3706500146 NO 10311312010 2 CWA NCO077437 NIA I lOcI-Dec09 6 Three Year Compliance Status by Quarter f��ta Dlctidnanj Violations shown in a given quarter do not necessarily span the entire 3 months. Information on the nature of alleged vtolaliens is available on the FAQ page, and information on the duration of non -Compliance is available at the end of this report. AIR Compliance Status Statute:Source ID QTR1 R3 OTR4 OTRS OTR6 OTR7 QTR1p QTR11 OTR12 CAA:3706500146 Apr• IOTR2 Jul- Oct- IQ Jan- Apr- Jul- Oct- IDeC08 10TI11 Jan- IQT119 Apr- Jul-Sep09 Oct Jan- Jun07 Sep07 Dec07 Mar08 Jun08 Sep08 MarO9 Juno9 Dec09 Marto HPV History Program/Pollutant in Current Violation MACT (SECTION C- C- C• C• C- C-INSP C-INSP C•SHUT IC -SHUT C-SHUT C-SHUT C-SHUT 63 NESHAPS) INSP INSP INSP INSP INSP DN ON ON ON ON TITLE V C• C- C- C• C• C-INSP C-INSP C-INSP C• C• C- C- PERMITS INSP INSP INSP INSP INSP PROCED PROCED PROCED PROCED SIP C- C- C- C- C- V- V- C• C• C• C- C- INSP INSP INSP INSP INSP PROCED PROCED PROCED PROCED PROCED PROCED PROCED PSD C- INSP C- IINSP C- IINSP C- IINSP C- INSP C-INSP C-INSP C-INSP C- PROCED C• PROCED C- PROCED C- PROCED NSPS C- C- C- C- C- C-INSP C-INSP C-INSP C- C- C- C- INSP INSP INSP INSP INSP PROCED PROCED PROCED PROCED High Priority Violator (HPV) History section: "Unaddr" means the facility has not yet been addressed with a formal enforcement action. "Addrs"means the facility has been addressed with a formal enforcement action, but its violations have not been resolved. Lead Agency designated can be US EPA, State, Both, or No Lead Determined. It HPV History is blank, then the facility was not a High Priority Violator. C.Compliance, V-Violation; S=Compliance Schedule. CWAINPDES Com fiance Status Statule:SOrrrce ID QTR1 OTR2 OTR3 OTR4 OTR5 OTR6 QTR7 0TH8 OTi QTR10 OTR11 OTR12 CWA:NCO077437 Jan- Apr- Jul- Och Jan- Apr- Jul- Oct- Jan- Apr- Jul- Ocl- Mar07 JL11107 Sep07 Dec07 Mar08 Jur)08 S0p08 D0008 Mar'09 Jun09 Sep09 Dec09 Non-compliance in NIA NIA Ill NIA NIA WA NIA NIA NIA NIA NIA NfA Quarter SNC. RNC Status NIA NfA Nil NiA Ill NIA NIA NIA NIA NIA NIA NIA Effluent Violations by NPDES Parameter: Get violation charts: all violations custom (click on parameter names for individual parameter charts) Effluent violations are displayed as highest percentage by which the permit limit was exceeded for the quarter. Bold, laril Indicates http://www.epa-echo.gov/cc,i-bin/get1 cReport.cgi?tool=echo&IDNuniber=110000604221 4/23/2010 EPA IDEA Query Results Page 3 of 5 0 Significant Non-compliance (SNC) effluent violations. Shaded boxes indicate unresolved SNC violations. Notices of Violation or Informal Enforcement - AFS, PCS, ICIS-NPDES, off, dactionary RCRAInfo (05 year history)" Statute Source ID Type of Action Lead Agency Date CAA 13706500146 ISTATE NOV ISSUED State 07/10/2008 CWA INCO077437 ILTR OF VtOLATs0NrWARNING LT t State 1051,10112008 Formal Enforcement Actions - (05 year history) AFS, PCS, RCRAllil NCDB LDataDfct6r ry Statute ISource ID IType of Action Lead Agency Date lPenaity IP9n71tyDescription No data records returned. In some cases, formal enforcement actions may be entered both at the initiation and final stages of the action. These may appear more than once above. Entries In italics are not "formal' actions under the PCS definitions but are either the initiation of an action or penalties assessed as a result of a previous action, This section includes US EPA and State formal enforcement actions under CAA, CWA and RCRA. 116-ka Dicti ry Primary Case Case Lead Case IssuedlFiled Settlement Federal State/Local SEP Comp Action LawlSectlon Number Type Agency Name Date Date Penalty Penalty Cost Cost - No data records returned. Federal enforcement actions and penalties shown in this section are from the Integrated Compliance Information System (ICIS-FEBC). These actions may duplicate records In the Formal Enforcement Actions section. Environmental Conditions f DstaDiclionary Permit ID lWaterShed lWatershed Name Recelving Waters ISection 303(d) Listing? lCombined Sewer System? NC0077437 103020101 1 Lover Tar, N.G. ITAR RIVER INO lNo TRI History of Reported Chemicals Released in Pounds per Year at Data�iotionary Site:27809CGNTRRTE2S Chemical releases reported to TRI are provided for context and are not associated with non-compliance for that facility. Year 1 Total Air Emissions Surface Water Discharges Underground Injections Releases to Land Total On -site Releases Total Off -site Transfers Total Releases and Transfers 1999 44,490 44,490 44,490 2000 33,840 5 33,845 33,845 2001 46,209 23 46,232 10,302 56,534 2002 56,239 55 56,294 27,812 84,106 2003 68,312 50 68,362 9,115 77,477 2004 68,705 133 68,838 4,745 73,583 2005 68,086 85 68,171 3,425 71,596 2006 57,745 31 57,776 3,404 61,180 2007 58,602 1 20 58,622 2,515 61,137 TRI Total Releases and Transfers by Chemical and Year Chemical releases and transfers are In pounds except where otherwise noted. Chemical Name 1999 1 2000 1 2001 1 2002 1 2003 2004 2005 1 2006 1 2007 ANTIMONY COMPOUNDS 1 1,419 3,104 ARSENIC COMPOUNDS ill 3,701 1 7.398 COPPER COMPOUNDS 1 1 14,387 1 6,123 littp://www.epa-echo.gov/cgi-bin/getI cReport.cgi?tool=echo&IDNumber=110000604221 4/23/2010 EPA IDEA Query Results Page 4 of 5 LEAD COMPOUNDS 1 5,285 3,762 3,305 4,273 1 3,090 3,451 2,530 MERCURY COMPOUNDS 34 109 123 59 49 44 40 61 ZINC COMPOUNDS 874 693 HYDROCHLORIC ACID 1995 AND AF 23,000 30,000 24,000 33,564 42,621 42,935 42,504 36,362 36,765 HYDROGEN FLUORIDE 2,800 3,700 3,020 4,196 5,328 5.367 5,313 4,545 4,596 SULFURIC ACID (1994 AND AFTER 18,690 1 19,000 17,572 20,041 20,085 19,952 16,782 17,185 DIOXIN AND DIOXIN-LfKE COMPOUN 46 47 44 Demographic Profile of Surrounding Area (3 Miles) jData bkljvnaryr Open more detailed information in a new window (links leave ECHO): I Mi 3 16 or 5 Mi. This section provides demographic information regarding the community surrounding the lacility. ECHO compliance data alone are not sufficient to determine whether violations at a particular facility had negative impacts on public health or the environment. Statistics are based upon the 2000 US Census data, and are accurate to the extent that the facility latitude and longitude listed below are correct. The latitude and longitude are obtained from the EPA Loratiunal Reference; I at?hILt3T) when available. Radius of Area: 3 Miles Land Area: 99.47% Households In area: 14,437 Center Latitude: 35.135813 Water Area: 0.53% Housing units In area: 15,353 Center Longitude: -80,917796 Population Density: 1326.991s , mi. Households on Public Assistance: 368 Total Persons: 37,315 Percent Minority: 61.04% Persons Below Poverty Level: 4,210 Race Breakdown Persons (%) Age Breakdown: Persons (%) White: 17,294 (46.35%) Child 5 ears and less: 3,241 ( 8.69%) African -americans 14.095 37.77°/ Minors 17 years and younger: 9,334 25,01% His anlc-ori in: 6,082 16.30% Adults 18 years and older: 27,981 74.99%) AslanlPacific Islander: 1,814 (4.86%) Seniors 65 years and older: 1,789 ( 4.79%) American Indian: 1315 ( 0.84%) Other/Multiracial: 12,507 ( 6.72%) flducall Level Parsons 25 &older) Persons (%) Income Breakdown: Households (%) Less than 9thgrade: 1,303 ( 6.00%) Less than $15,000: 1,366 9.46% 9th-12thgrades: 2,628 12.09% $15,000-$25,000: 1,654 (11.46%) High School Diploma: 5,827 (26.82%) $25,000-$50,000: 5,359 (37.12%) Some College/2- r: 6,264 (28,83%) $50,000-$75,000: 3,481 (24,11% B.S./B.A. or more: 15,708 (26.27%) Greater than $75,000: 12,521 {17.46%) Please note: Entries in gray denote records that are not federally required to be reported to EPA. These data may not be reliable. Notice About Duration of Violations -- The duration of violations shown on this report is an estimate of the actual duration of the violations that might be alleged or later determined in a legal proceeding. For example, the start date of the violation as shown in the ECHO database is normally when the government first became aware of the violation, not the first date that the violation occurred, and the facility may have corrected the violation before the end date shown. In some situations, violations may have been corrected by the facility, but EPA or the State has not verified the correction of these violations. In other situations, EPA does not remove the violation flag until an enforcement action has been resolved. 0,14. This report was generated by the Integrated Data for Enforcement Analysis (IDEA) system, which updates its information from program databases monthly. The data were last updated: Al 03/13/2010. PCS: 03/13/2010. FRS: 03/11/2010. Tl 05/05/2009. Some regulated facilities have expressed an interest in explaining data shown In the Detailed Facility Reports in ECHO. Please check company web sites for such explanations. http://www.epa-echo.gov/egi-bin/get 1cReport.egi?tool=echo&IDNuniber= l 10000604221 4/23/2010 EPA IDEA Query Results Page 5 of 5 EPA Home I Privacy and Security Notice I Contact Us http://www.epa-echo,gov/cgi-bin/getl cReport.cgi?tool=echo&IDNumber=110000604221 4/23/2010 �~ `EPA I Envirofacts Warehouse I TRI Page i of 9 Toxics Release Inventory (TRI) httpa/laspub.epa.yov/rnvlro/tris_tnntrnLh'I5_pr1nF)trls td=37EiF39CGN7RR'T'E25 Last updated an rr'idaV, Anrll 21, 261.0 YOU are mere: EPA.Hvme. Envlrofaets TRI Lrlvirorrcta Rrpnrt Envirofacts Report 14 TRI Query executed on APR-23-2D10 Results are based on data extracted on MAR-02-2010 Click on "View Facility Information" to view EPA Facility Information for the facility. FaclHty_Name:. EDGECOMB GENCO LLC Mailing -Name: EDGECOMB GENCO LLC Address: 6358 OLD BATTLEBORO RD Malling_Addre$S,. PO BOX 370 BATTLEBORO NC 27809 BATTLEBORO NC 27809 County: EDGECOMBE Realon. 4 Facllity Information: View Facility Information TRI ID; 27809CGNTRRTE2S DUNS Number: 131411837 FRSID 110000604221 TRI Preferred Latitude: TRI Preferred Longitude; Public Contact; BILL MAIDEN Phone: 2524420805 Parent Company; COGENTRIX Parent,DUNS: 131411837 Starting with Reporting Year 2006, TRI Facilities began reporting NAICS codes, Instead of SZC codes, to Identify their Primary Business Activities. NAICS Codes for2008 �®® NAICS DESCRIPTION 221112 YES Fossll Fuel Electric Power Generation The above Information comes from 2008, which was the last year NAICS code data was reported for this facility. The earliest NAICS code data on file for this facility was reported In 1998. n Map this facility Map this facility using one of Envlrofact's mapping utilities. Besides TRI, this facility also does the following: • has reported air releases under the Clean Air Act • has permits to discharge to water More information about these additional regulatory aspects of this facility can be found by pressing the other regulatory data button below. Other Regulatory Data Total Aggregate Releases of TRI Chemicals to the Environment: For all releases estimated as a range, the mfd-point of the range was used in these calculations. This table summarizes the releases reported by the facility. NR - signifies nothing reported by this facility for the corresponding medium, Total Aggregate Releases of TRI Chemicals excluding Dioxin and Dioxin -like Compounds (Measured In Pounds) Media Alr emissJQfla 2008 55571.4401 2007 58602.630i 2006 57745,6301 2005 fi8087.32 2004 68705,5 Z003 fi8313,5852 20D2 56Z40,86 2001 46209 2080 33$40 1999 44490 1998 42900 Isurfac Water piadiftEm ReleaseS_to 1.94 NR 20,514 NR 3L86 NR 86,176 NR 133,836 NR 50,615 NR� 56,b36 OII 2`3`,1`2` OI 5,11 NR NR NR NR NR http://iaspub.cpa.gov/enviro/tris_control.tris_pritit?tris_id=27809CGNTRRTE2S 4/23/2010 EPA I Envirofacts Warehouse I TRI Page 2 of LT I " Underaround In ectlon NR NR NR NR NR NR NR NR NR NR NR Total On -Site Releases 55573.3801 58623.1441 57777.4901 68173,496 68839.336 68364.200z 56297,446 6232.12 33845.11 44490 42900 Site tom NR NR 2.8E 3428.E 4745.9 S7i4.05 27813.39 10302 NR NR gNTotal Releases 55573 38D1 58623.1441 57780.3501 71602.04E 73585.23E 74083.25D2 84110,88E 56534.12 33845.11 44490 .. Graphic Summary of this Table I Total Aggregate Releases of Dioxin and Dioxin -like Compounds (Measured In Grams) Media 200E 2007 200E 2005 2004 200i 2002 2001 2000 1999 1998 Air_Emission;I .56 595 588 .687 ,694 .689 44.3 F47 17]F 451F NR 7NR surface Watar Discharges NR NR NR NR NR NR NR NR L R NR 7 NR Re I i n otal On -Site Releases NR NR .56 NR NR .595 NR NR .588 NR NR .687 NR NR .644 NR NR ,689 NR NR 44.3 NR NR 47.17 NR NRI 46 NR NR NR NR NR NR Transfer Off-S t to Dispel NR NR NR NR NR NR NR NRI NR !VR NR otai Releases 56 .545 .588 .687 .694 .689 44.3 47,i7 46 NR NR Graphic Summary of this Table TRI Chemicals Reported on Form A: Please note that there were no chemicals reported on form A for this facility NOTE: All chemicals reported below have release or transfer amounts greater than zero. To see a list of all chemicals reported by this facility click here• Names and Amounts of Chemicals Released to the Environment by Year. For all releases estimated as a range, the mid -point of the range was used in these calculations. NR - signifies nothing reported for this facility by the corresponding medium. Rows with all "0" or "NR" values were not listed. Chemical Name Media —10-"- �4 2C108 20707 200E 2005 5004 2Q03 2002 2001 2000 1999 1998 ANTIMONY COMPOUNDS TRI Chemlcal ID: N010 STACK Pounds NR NR NR NR NR NR 44,3 27 NR NR NR ANTIMONY COMPOUNDS 7RI Chemical ID: N010 OISF�_ NQN NETALS pounds NR NR NR NR NR NR 3077 139D NR NR NR ANTIMONY COMPOUNDS TRI Chemical ID: N010) WATER Pounds NR NR NR NR NR NR 3.SG __L J_2 NR NR NR ARSENIC COMPOUNDS TRI Chemical 1D: N020) ALB Pounds [:EF NR NR NR NR NR 74,4 101 106 NR NR ARSENIC COMPOUNDS 7RI Chemlcal 10: N020 DISP_NON pounds NR NR NR NR NR NR 7324 3600 NR NR FNR ical ID: ND5 (TRI NICChemical TRI Chemical ID: N020 ���ii��:FA--LLS��`` pounds NA NR NR NR NR NR 59 NR NR COPPERCOMPDUNDS (TRI Chemltal ID: N100) COPPER COMPOUNDS TRI Chemlcal ID: N100 AIR_FUG STACK Pounds Pounds NR NR NR NR NR NR NR NR NR�� NR 550 750 NR NR NR NR NR NR NR NR COPPER COMPO_UND_S TRI Chemical ID: N100 DI_SP NON pounds NR NR NR NR NR 3666.2 13615 NR RN NR NR CPE OPR.QMPOUNDS TRI Chemical ID: N100 ���I--j��E--TAALL'S Pounds NR NR NR NR NR 21.13 22 NR NR NR NR DIOXIN AND DIOXIN-LIKEITACK❑❑❑❑❑❑❑❑❑ Grams 56 595 588 687 694 689 44,3 47.17 46 NR ❑ NR ❑ COMPOUNDS TRI Chemical ID: N150 HYDROCHLORIC ACID �1995 ��nnnnn����nnnn http://iaspub.epa.gov/enviro/tris_conti-ol.tris_print?tris_id=27809CGNTRRTE2S 4/23/2010 .Al 'FSPA I Envirofacts Warehouse I TRI Page 3 of 9 AND AFTER "ACID AEROSOLS" ONLY] (TRI Chemical ID; STACK Pounds 3a625 36765 U36362 U42504 [12J935L42],521 33564 24000 3 0000 23000 230DO 007647010 HYDROGEN FLUORIDE (TRI Chemical ID: AIR Pounds 4328EE 5313 5367 5328 419E 3020E 2800 2900 007664393 STACK LEAD COMPOUNDS TRI Chemical ID N420) A[R FUG ppund5 tl4 .04 p4 0 0 .035 .04 0 NR NR NR LEAD COMPOUNDS TR] Chemical ID: N420 STACK Pounds 26.6E 55.15 E5,15 3L57 31,4 3L7 E6,95 E6 NR NR NR BEAD COMPOUNDS TRI Chemlcal ID: N420 DISP NO NIEIALS pounds NR NR 2.85 0047 4220 2036.78 3708.4b 5238 NR NR NR LEAD COMPOUNDS TRI Chemical ID: N420 Pounds 1,8E 20,39 31,67 13J5 22,1 29,31 30,3 21 NR NR NR MERCURY COMPOUNDS TRI Chemlcal ID: N458 Paund5 .0001 ,0001 A001 �F ,000E �D NR NR NR MERCU Y COMPOUNDS TRI Chemical ➢D: N458 AIR STACK pounds 1.78 31.44 31.44 36.75 37.1 36.85 33.17 35 34 NR NR MERCURY COMPOUNDS TRI Chemlcal ID: N458 D15P NDN tl�T.ALS pounds NR NR O1 9,3 12,9 16,D7 90,93 74 NR NR NR MERCURY COMPOUNDS TRI Chemical ID: N458) VygTER Pounds OB 124 .19 .08E .13E .175 .18E .12 .11 NR NR S U LFU RI C. ACI D_(199 A_AN D AFTER "ACID AEROSOL$" AIR STACK pounds 16590 17185EEH2EE NR ]18690 ]17000 ONLYI (TRI Chemical ID: 007664939 ZINC COMPOUNDS TRI Chemical ID: N982) AIR STACK pounds NR NR NR E50 250 NR NR NR NR NR NR ZINC COMPOUNDS TRI Chemical iD: N982) D15P NON METALS pounds NR NR NR 372,3 513 NR NR NR NR NR NR OallIID:SN982) � Pounds NR NR NR 72,34 111,E NR NR NR NR NR NR (TRI CheempcIZINC Discharge of Chemicals into Streams or Bodies of Water: For all releases estimated as a range, the mid -point of the range was used in these calculations. Rows with Release Amount equal to '0' were not listed. IChemical Name Y r Unit_Of MedSN_r@ RQase Amok r m r B f W t ANTIMONY COMPOUNDS TRI Chemical ID; NO10 2D02 Pounds 3,5E TAR RIVER ANTIMONY COMPOUNDS TRI Chemical 1D: NO1p 2D01 Pounds 2 TAR RIVER ARSENIC -COMPOUNDS. (TRI Chemlcal ID: N020 200E pounds .59 TAR RIVER ARSENIC COMPOUNDS TRI Chemical ID: N020 2000 Rounds 5 TAR RIVER COPPER COMPOUNDS Z003 Pounds 21.13 TAR RIVER TRI Chemical ID; N100 COPPER COMPOUNDS TRI Chemical ID; N100 200E Pounds 22 TAR RIVER LEAD_COMP_OUNDS TRI Chemical ID: N420 2008 Pounds 1,8E TAR RIVER LEAD —COMPOUNDS TRI Chemical ID: N420 2007 Pounds 20.39 TAR RIVER BEAD COMPOUNDS TRI Chemical 1D; N420 200E Pounds 31.67 TAR RIVER COMPOUNDS I2005 LEAD TRI Chemical ID; N420 Pounds 13.75 TAR RIVER LeAD_COMPOL)NDS 2004 pounds 22.1 TAR RIVER TRI Chemical ID: N420 LEAD COMPOUNDS TRI Chemical 10: N420 2003 Pounds 29.31 TAR RIVER LEAD comPOUNDS 200]2 Pounds 30.3 TAR RIVER TRI Chemical ID: N420 littp:Hiaspub.epa.govlenviroltris_control.tris_print?tris_id=27809CGNTRR'rE2S 4/23/2010 EPA I Envirofacts Warehouse I TRI Page 4 of 9 LEAD COMPOUNDS TRI Chemical ID: N420 2001 Pounds 21 TAR RIVER MERCURY COMPOUNDS TRI Chemical ID: N458 2008 Pounds .08 TAR RIVER MERCURY_COMPOUNDS TRI Chemical ID: N458 2007 Pounds .124 TAR RIVER IMERCURY COMPOUNDS 2006 Pounds 19 TAR RIVER TRI Chemical ID: N458 TRI Chemical ID: N458) 2005 PoundsOMPOJNDS 086 TAR RIVER MERCURY COMPOUNDS. TRI Chemical ID: N458 2004 Pounds 13b TAR RIVER TRI Chemical 10: N458 2003 Pounds 175 TAR RIVER MERCURY COMPOUNDS (TRI Chemical ID: N458) 2002 ❑ Pounds il 186 TAR RIVER MERUR_Y,� OP UNQS. TRI Chemical ID: N45$ 2001 Pounds .12 TAR RIVER MERCURY COMPOUNDS TRI Chemical 10: N458 2000 Pounds .11 TAR RIVER ZINC COMPOUNDS TRI Chemical 10: N982 2005 Pounds 72.34 TAR RIVER VVVV ZIN_COMPOUNQS (TRI Chemical ID: N982} 20D4 Pounds 111.6 TAR RIVER Transfer of Chemicals to Off -Site Locations other than POTWs: Please note that transfer amounts are not included in release totals shown above. for all releases estimated as a range, the mid -point of the range was used in these calculations. Rows with Total Transfer Amount equal to "0" were not listed. Chomlcal._Name Year. Unit Of Total Transfer Tran..sfer Slte-Name_and-Address Type -Of -waste Measure Amount Management AHTI_MONY COMPOUNDS FOUNTAIN INDUSTRIAL PARK Other Off -Site (TRI Chemical ID: 2002 Pounds 3077 1D1 FOUNTAIN PARK ROAD Management N010 ROCKY MOUNT, NC 27802 ANTIMONY (TRI Chemical 10: 2061 Pounds 1390 FOUNTAIN INDUSTRIAL PARK 101 FOUNTAIN PARK ROAD Other Off -Site Management N010) ROCKY MOUNT, NC 27802 ARS'ENIC COMPOUNDS FOUNTAIN INDUSTRIAL PARK Other Off -Site (TRI Chemical ID: 2002 Pounds 7319 101 FOUNTAIN PARK ROAD Management N020 ROCKY MOUNT, NC 27802 ARSENIC SAMPSON COUNTY LANDFILL COMPOUNDS (TRI Chemical ID: 2002 Pounds 5 7434 ROSESORO HWY Other Landfills NazD) ROSEBORO, NC 28382 ARSENIC COMPOUNDS FOUNTAIN INDUSTRIAL PARK Other Off -Site (TRI Chemical ID: 2001 Pounds 3600 101 FOUNTAIN PARK ROAD Management N020 ROCKY MOUNT, NC 27802 COPPER COMPOUNDS 2003 Pounds 1768.08 REUSE TECHNOLOGY INC. SWIFT CREEK FACILITY Other Off -Site (TRI Chemical ID: N100) 101 FOUNTAIN PARK ROAD Management BRTTLEBORO NC 27809 COMPOUNDS [2�003 Pounds 4.74 WASTE INDUSTRIES 7434 ROSEBORO HWY Other Landfills �COPPER (TRI Chemical ID: NIOD)ROSEBORO NC 28382 F2O03 Pounds 2183.22 FAY BLOCK 1108 RAMSEY STREET Other Reuse or Recovery (TRI Chemicah ID: N100) FAYETTEVILLE,NC 28302 COPPER COMPOUNDS 2003 Pounds 761.19 PETERS POINT BUSINESS PARK 2782 BOYDTON PLANK RD 1PETERSBURG,VA Other Off -Site Management (TRI Chemical 1D: N100) 23805 COPPER COMPOUNDS 2 003 ❑� Pounds 760.88 �TAYLORS OF FAYETTEVILLE 9340 CHICKPEE DR. FtheOff-Site(TRI ement Chemical 1D: N100) LINDEN, NC 28356 COPPER COMPOUNDS (TRI Chemical ID: F200]3FPc.nds7 359.03 �BRUNSWICK WASTE MANAGEMENT 107 MALLARD CROSSING ROAD Other Landfills http://i,,ispub.epa.gov/enviro/tiis 4/23/2010 EPA I Envirofacts Warehouse I TRI Page 5 of 9 IN100) JUI �� [,f LAWRENCEVILLE, VA 23868 COPPER COMPOUNDS 2003 Pounds 12.28 HQUGHTON INDUSTRIAL PARK 2529 HOUGHTON AVE Other Off -Site Management (TRI Chemical ID: N100) SOUTH BOSTON VA 24592 COPPER COMPOUNDS 2002 Pounds 13615 FOUNTAIN INDUSTRIAL PARK 101 FOUNTAIN PARK ROAD Other OFF -Site Management (TRI Chemical ID: N100 ROCKY MOUNT NC27802 SOUTHBOSTON RECREATIONAL MPOUNDS 2008 Pounds 110 FACILITYmical 2411 YOUNGER AVE Other Reuse or Recovery [D: fN4 SOUTH BOSTON, VA 24592 LEAD COMPOUNDS 2008 Pounds 5470 Y BLOCK BUILDERS BLVD rFA [Other Reuse or Recovery (TRI Chemical ID: N420 YETTEVILLE, NC 28302 SAD COMPOUNDS 200$ Pounds 1183 AGRICULTURAL PRODUC75 (EVANS FARMS) 1510 COLONY DR Other Reuse or Recovery (TRI Chemical ID: N420) TARBORO NC 27866 LEAD COMPOUNDS MCGILL SUSSEX (TRI Chemical [D: 2008 Pounds 993 BEEFSTEAK RD Other Reuse o=Recovery N420) WAVERLY VA 23890 LEAD CO..PO.UNDS (TRI Chemical ID: N420) LEAD COMPOUNDS 2008 2007 Pounds Pounds 162 718 BRANDYWINE FARMS 13705 BUNDLE RO CHESTERFIELD VA 23838 FAY BLOCK 130 BUILDERS BLVD ether Reuse or Recovery Other Reuse or Recovery (TRI Chemical ID: N420) FAYETTEVILLE, NC 28302 LEAD COMPQ"'�SLANCASTER 2007 PoundsF 10 FARMS BRIDGE ROAD ISUFFOLK,VA Other Reuse or Recovery (TRI Chemical ID: N420 23432 LEAD COMPOUNDS 2007 ❑� Pounds 990,09 BRANDYWINEFARMS 13705 BUNDLE ROAD ICHE57ERFIELD, Other Reuse or Recovery (TRI Chemical ID: N420) VA 23838 LEAD COMPOUNDS [2�UO7 Pounds 767 PETERS POINTE COMMERCE PARK DO NOT KNOW IPETERSBURG, Other Reuse or Recovery (TRI Chemical ID: N420 VA 23803 LEAD COMPOUNDS 2006 Pounds 2,85 SAMPSON COUNTY LANDFILL �7434 ROSEBORO HWY Other Landrills (TRI Chemical ID: N420) ROSEBORO, NC 28382 LEAD COMPOUNDS 2006 Pounds 718.38 LANCASTERFARM$ BRIDGE ROAD Other Reuse or Recovery (TRI Chemical ID: N420 SUFFOLK,VA 23432 LEAD COMPOUNDS [2�006 Pounds 802,54 FAY BLOCK 130 BUILDERS BLVD Other Reuse or Recovery (TRI Chemical ID: N420 FAYETTEVILLE NC 28302 LEAD COMPOUNDS 2006 Pounds 1524.54 18RANDYWINE FARMS 13705 BUNDLE ROAD Other Reuse or Recovery (TRI Chemical ID: N420 CHESTERFIELD VA 23838 LEAD_ COMPO>))>URDS 2006 Pounds 1,13 PETERS POINTS COMMERCE PARK DO NOT KNOW 1PETERSBURG, Other Reuse or Recovery (TRI Chemical ID: N420 VA 23803 LEAD COMPOUNDS 2006 Pounds 348,16 REUSE FOUNTAIN INDUSTRIAL PARK 11 Other Reuse or Recovery (TRI Chemical ID: N420) ROCKY MOUNT, NC 27801 REUSE TECHNOLOGY INC. SWIFT CREEK OMPOUNDS 2005 Pounds 1206.1 FACILITY Other Off -Site emical ID: ff(N42O 101 FOUNTAIN PARK ROAD Management BATTLEBORO,NC 27809 LEAD COMPOUNDS 2005 Pounds 1044.4 FAY BLOCK 1108 RAMSEY STREET Other Off site Management (TRI Chemical ID: N420) FAYETTEVILLE, NC 28302 LEAD_COCIQOUNDS BRtNSWICK WASTE MANAGEMENT (TRI Chemical ID: R05 Pounds 796.5 107 MALLARD CROSSING ROAD Qther Landfills N420 LAWRENCEVILLE VA 23868 REUSE TECHNOLOGY INC. SWIFT CREEK LEAD_CONIPOUNDS 1343 FACILITY Other Off -Site (TRI Chemical ID: HEP�, ds 101 FOUNTAIN PARK ROAD Management N42D} BATTLEBORO,NC 27809 LEAD COMPOUND5 2 004 Pounds 2$77 BRUNSWICK WASTE MANAGEMENT 107 MALLARD CROSSING ROAD ILAWRENCEVILLE,VA Other Landfills (TRI Chemical ID: N420) 23868 http://iaspub.cpa.gov/enviro/tris_control.tris_print?tris_id=27809CGNTRRTE2S 4/23/20.10 EPA I Envirofacts Warehouse I TRI Page 6 of 9 LEAD COMPOUNDS 2 003 Pounds 982.27 REUSE TECHNOLOGY INC. SWIFT CREEK FACILITY Other Site (TRI Chemical ID, N420) 101 FOUNTAIN PARK ROAD Management BATTLEBORO,NC 27809 LEAD COMPOUNDS H Pounds WASTE INDUSTRIES 7434 ROSESORO HWY Other Landfills (TRI Chemical ID: N420) ROSEBORO, NC 28382 LEAD COMPOUND$ (TRI Chemical ID: N420 2003 Pounds 6,82 �HOJGHTON INDUSTRIAL PARK 2529 HOUGHTON AVE SOUTH BOSTON VA 24592 Other eSite Management LEAD CQMEOUNDS 2003 Pounds 199.45 BRUNSWICK WASTE MANAGEMENT 107 MALLARD CROSSING ROAD Other Landfills (TRI Chemical ID: N420) LAWRENCEVILLE, VA 23868 LEAD COMPOUNDS 2003 Pounds 422.71 �TAYLORS OF FAYETTEVILLE 9340 CHICKPEE DR. Other emOffSite Management (TRI Chemical IQ, N420 LINDEN NC 28356 LEAD COMPOUNDS 2003 Pounds 422.B9 TERS POINT BUSINESS PARK 82 BOYDTON PLANK RD OTERSBURG, Other Off site Management RI Chemical ID, 0 20) VA 23805 LEAD—COMPOUNDS FAY BLOCK (TRI Chemical ID: 2003 Pounds 1212.91 1108 RAMSEY STREET Other Reuse or Recovery N420) FAYETTEVILLE, NC 28302 LEAD COMPOUNDS 2002 Pounds 3704 FOUNTAIN 1NpUSTRIAL PARK 101 FOUNTAIN PARK ROAD Other Off Site Management (TRI Chemical ID: N420 ROCKY MOUNT NC 27802 SAMPSON COUNTY LANDFILL �LEAD._COMPOUN_D5 (TRI Chemical ID: 2002 Pounds 2.46 7434 ROSEBORO HWY Other Landfills 11420)ROSEBORO NC 28382 LEAD COMPOUNDS F2O1 Pounds 5238 FOUNTAIN INDUSTRIAL PARK 101 FOUNTAIN PARK ROAD ROCKY MOUNT NC 27802 Other Off -Site Management (TRI Chemical ID: N420 MERCURY COMPOUNDS BRANDYWINE FARMS (TRI Chemical 1D: 2008 Pounds 47 13705 BUNDLE RD Other Reuse or Recovery N458) CHESTERFIELD, VA 23838 MERCURY AGRICULTURAL PRODUCTS (EVANS COMPOUNDS 2008 Pounds 3.4 RMS) Other Reuse or Recovery (TRI Chemical ID: 10 COLONY DR RRBORO, N458 INC 27866 MERCURY MCGILLSUSSER COMPOUNDS (TRI Chemical ID: 2008 Pounds 2.8 BEEFSTEAK RD Other Reuse or Recovery N458 WAVERLY, VA 23890 MERCURY SOUTH BOSTON RECREATIONAL FACILITY (TRI Chemical ID; 200$ Pounds 3 2411 YOUNGER AVE Other Reuse or Recovery N458) ISOUTH BOSTON, VA 24592 MERCURY FAY BLOCK COMPOUNDS (TRI Chemical ID: H Pounds 1.57 130 BUILDERS BLOCK Other Reuse or Recovery N458) FAYETTEVILLE, NC 28302 MERCURY COMPOUNDS (TRI Chemical ID: 2007 Pounds 9.75 PETERS POINTE COMMERCE PARK DO NOT KNOW Other Reuse or Recovery N458 PETERSBURG, VA 23803 MERCURY COMPOUNDS LANCASTER FARMS (TRI Chemical [D: 2007 Pounds 125 BRIDGE ROAD Other Reuse or Recovery N458 SUFFOLK, VA 23432 MERCURY FAY BLOCK MP r (TRI Chemical ]D: H Pounds 9,11 130 BUILDERS BLVD Other Reuse or Recovery N458 FAYETTEVILLE, NC 28302 MERCURY BRANDYWINE FARMS COMPOUNDS Chemical ID: H Pounds 12.57 13705 BUNDLE ROAD Other Reuse or Recovery N458(TRI CHESTERFIELD, VA 23838 MERCURY COMPOUNDS (TRI Chemical ID: H Pounds 1.05 REUSE FOUNTAIN INDUSTRIAL PARK Other Reuse or Recovery N458 ROCKY MOUNT, NC 27$DI MERCURY nF 1 http:lliaspub.epa.gov/eiivii-o/tri.s_control.tri s—print7ti-is—id=27809CGNTRRT.E2S 4/23/2010 EPA I Envirofacts Warehouse I TRI Page 7 of 9 COMPOUND R18Chemi al ID: 2006 Pounds 4,59I13705 FARMS ROAD{Other BUNDLEA Reuse or Recovery NBNDYWINE VA p3838 i CHESTMERCURY SAMPSON COUNTY LANDFILL COMPOUNDS (TRI Chemical ID: N458 2006 Pounds Al 7434 ROSEBORO HWY ROSEBORO, NC 28382 Other Landfills MERCURY COMPOUNDS (TRI Chemical ID: N458 2006 Pounds 2.16 LANCASTER FARMS BRIDGE ROAD SUFFOLK, VA 23432 Other Reuse or Recovery MER0B1 COMPOUNDS (TRI Chemical ID: N458 2006 Pounds 2.42 FAY BLOCK 130 BUILDERS BLVD FAYETTEVILLE, NC 28302 Other Reuse or Recovery MERCURY BRUNSWICK WASTE MANAGEMENT COMPOUNDS (TRI Chemical ID: N458 H Pounds 2.43 107 MALLARD CROSSING ROAD LAWRENCEVILLE, VA 23868 Other Landfills MERCURY COMPOUNDS (TRI Chemical ID: N458 2005 Pounds 3.19 FAY BLOCK 110E RAMSEY STREET FAYETTEVILLE, NC 28302 Other Off-51te Management REUSE TECHNOLOGY INC, SWIFT CREEK COMPOUNDS (TRI Chemical ID: N458) 2005 Pounds 3,68 FACILITY 101 FOUNTAIN PARK ROAD BATTLEBORO,NC 27809 Other Off -Site Management MERCURY COMPOUNDS (TRI Chemical ID: N458) 2004 Pounds 8,8 REUSE TECHNOLOGY INC. SWIFT CREEK FACILITY 101 FOUNTAIN PARK ROAD BATTLEBORO,NC 27809 BRUNSWICK WASTE MANAGEMENT Other Off -Site Management MERCURY COMPOUNDS (TRI Chemical ID: N458 MERCURY. EE 4.1 107 MALLARD CROSSING ROAD LAWRENCEVILLE, VA 23868 BRUNSWICK WASTE MANAGEMENT Other Landfills COMPOUNDS (TRI Chemical ID: N458 2003 Pounds 1.57 107 MALLARD CROSSING ROAD LAWRENCEVILLE, VA 23868 Other Landfills MERCURY COMPOUNDS (TRI Chemical ID: N458 2003 Pounds 3,34 TAYLORS OF FAYETTEVILLE LINO CHICKP 8356 LINDEN, NC 2 Other Off -Site Management ME&CU CQMPS?QNQS (TRI Chemical ID: N458 2003 Pounds 3.34 PETERS POINT BUSINESS PARK 2782 BOYDTON PLANK RD PETERSBURG, VA 23805 Other Off -Site Management MERCURY FAY BLOCK COMPOUNDS (TR] Chemical ID: N458 2003 Pounds 9.57 1108 RAMSEY STREET FAYETTEVILLE, INC 28302 Other Reuse or Recovery MERCURY C I Chemical ID: (TRI Chec 4458) 2003 Pounds .02 WASTE INDUSTRIES 7434 ROSEBORO HWY ROSEBORO, NC 28382 Other Landfills MERCURY COMPOUNDS (TRI Chemical [D: N458 2003 Pounds 7.75 REUSE TECHNOLOGY INC. SWIFT CREEK FACILITY 101 FOUNTAIN PARK ROAD BATTLEBORO,NC 27809 Other Off -Site Management MERCURY COMPOUNDS (TRI Chemical ID: N458 2003 Pounds 05 HOUGH70N INDUSTRIAL PARK 2529 HOUGHTON AVE SOUTH BOSTON, VA 24592 Other Off -Site Management MERCURY (TRI Chemical ID: N458 2002 Pounds 90.73 TAIN INDUSTRIAL PARKCOMPOUNDS FOUNTAIN PARK ROAD [R00:CKY MOUNT, INC 27802 Other Off -Site Management MERCURY COMPOUNDS (TRI Chemical ID: N45$ 2002 Pounds 2 SAMPSON COUNTY LANDFILL 7434 ROSEBORO HWY ROSEBORO, NC 28382 Other Landfills MERCURY -77IF-71 COMPOUNDS FOUNTAIN INDUSTRIAL PARK Other Off -Site http://iaspub.cpa.gov/cnviro/tris_control.tris,print?tris_id=27809CGNTRRTE2S 4/23/2010 EPA I Envirofacts Warehouse I TRI Page 8 of 9 (TRI Chemical ID: N458) 2001 Pounds 74 101 FOUNTAIN PARK ROAD ROCKY MOUNT NC 27802 Management REUSE TECHNOLOGY iNC. SWIFT CREEK ZINC COMPOUNDS 2005 Pounds 147.4 FACILITY Other Off -Site (TRI Chemical ID: N982} 101 FOUNTAIN PARK ROAD Management BA7TLE80R0, NC 27809 ZINC COMPOUNDS 2005 Pounds 127,6 FAY BLOCK 1108 LOCK STREET Other Off Site Management (TRI Chemical ID: N982 FAYETTEVILLE NC 28302 ZINC COMPOUNDS 2005 Pounds 97,3 JBRUNSWICK WASTE MANAGEMENT 107 MALLARD CROSSING ROAD Other Landfills (TRI Chemical ID: N982) LAWRENCEVILLE, VA 23868 REUSE TECHNOLOGY INC. SWIFT CREEK ZINC COMPOUNDS 2004 Pounds 163 FACILITY Other Off -Site (TRI Chemical ID. N982} 101 FOUNTAIN PARK ROAD Management BATTLEBORO, NC 27809 Z MP UND 2004 Pounds 350 BRUNSWICK WASTE MANAGEMENT 107 MALLARD CROSSING ROAD Other Landfills (TRI Chemical ID: N982) LAWRENCEVILLE, VA 23868 Summary of Waste Management Activites Please note that chemical amounts shown here are not included in Total Aggregate Releases shown above. Summary of Waste Management Activites excluding Dioxin and Dioxin -like Compounds (Measured in Pounds) Year g�CXCllno �� Re�]frllna gy ReOn-Site Enemy Recovery Offgly_ ftte Enerav Re�pYerV T tmgpt [ ���tIDflflk Total Amount 2007 00 oil 0 735120.16I�J �Off_Site 735120.18 2008 0 0 697297.54 0 697297.54 2009 Projected) ®r D� 01 0 712508.E �0 712508.E 2010 Pro ected} ©0j ul 0 722109 0 722109 Summary of Waste Management Activites for Dioxin and Dioxin-Ilke Compounds (Measured in Grams) This facility did not report any waste management activates for Dioxin and Dioxin -like Compounds. Chemicals Under Waste Management: Please note that chemical amounts shown here are not included in the Total Aggregate Releases shown above. Transfers to Publicly Owned Treatment Works are listed on a seperate table. Chemical Name AND APTERnACID AHYDRO CH LRIIEROSOLS" 1[2007 DNLY1 �� Unit Of Pounds On-S!te Recvclino ����L� Off -Site Rp�yclina Rec11 Ecove� -Off RecEnover On -Site Trepted 459960 Trea ed D Total Amount 459960 2008 Pounds 00L.01t--� 4328171 432817 2009 Projected) Pounds �I 41� ] 450000 �0 450000 2010 I(Projected) pounds �I I�� 451000 451000 HYDROGEN FLUORIDE 2008 jPourds 0 0 0 0 54102 0 54102 2009 (Projected) pounds 0 01 Oi 0 54500 �0 54500 2010 pounds J(Projected)ll��ll ���� 56000� 56000 LEAD COMPOUNDS 2007 Pounds ���^-^��� 2894 ® 2894 2008 Pounds L�. VIL -.�0 29950 2995 --J009 2Pro ected Pounds I Ol��` l 3000 3000 2010 Proected pounds ���� �01 310D � 3100 http://iaspub.epa.gov/enviro/tris_control.tiis_print?tris_id=27809CGNTRRTE2S 4/23/2010 EPA I Envirofacts Warehouse I TRI Page 9 of 9 MERCURY COMPOUND5 112007 1pounds 1 01 01 0 01 9.161 0 9.18 2D08 2009 Projected Pounds �0 �0 �0 © 8.54 ® 8.54 2010 Pro ected Pounds 0 0 0 9 0 9 5 U LEU RI C. ACI D_(199_4_AN D AE7ER "ACT122007 Pounds 0 0 0 0 214812 0 214812 ONLY1 2008 2009 Pro'ected Pounds pounds �r--�®� ���� 207375�0 205000 207375 205000 2010 Prv'ected) pounds ���� 212000 212000 Transfer of Chemlcals to Publicly Owned Treatment works (POTW): This facility did not transfer any chemicals to a Publicly Owned Treatment Works (POTW). Non Production Releases: This report shows the quantities of the chemicals released to the environment by reporting year as a result of remedial actions, catastrophic events, or other one-time events not associated with production processes. Chemicals with zero release amounts are not shown. Chem 1 Nama R r In Y r Unit Of M@?54+r Release Quantity D NANLDl0X1N -LIKE COMEQUNDS112007 IlGrams F .595 DIOXIN AND DIQXIN-LIKE QQMPO_l)NDS 2006 Grams .588 HYDROGEN FLUORIDE 111ounds 4545 LEAD COMPOUNDS jPounds 3428 MERCURY comPOUNDS 2007 Pounds 31.564 Addttlonal links for TRI: This information resource is not maintained, managed, or owned by the Environmental Protection Agency (EPA) or the Envirofacts Support Team. Neither the EPA nor the Envirofacts Support Team is responsible for their content or site operation. The Envlrofacts Warehouse provides this reference only as a convenience to our Internet users. National Library of Medicine (NLM) C http://iaspub.epa.gov/etiviro/tris_control.tris_print?tris_id=27809CGNTRRTE2S 4/23/2010 NCNHP Virtual Workroom Page 1 of 1 Legend Element Occurrences J (show after queried) (✓ ,.' l EO Source Points EO Source Lines !ZI, 1�j EO Source Polygons '1J submitted EOs 3, Sipnll'ir Naturai ' Heritage Areas Managed Areas r Roads �I MuNclpalktles r., '*? RNers and Lakes !.._! Topo Images i 112111 Aerial Images (2008) C� Aerial Image., (1998) [] Topo Boundaries !! i........i County Boundaries I� Redraw Map NC Natural Heritage Program Virtual Workroom 0 0.3 0.6 0.9 1.2 mi GIS Data Sources: NCNHP, CGIA, NCOOT, uSGS. NCNHP data updated on: 2030-Apr-23 Powered By: ■ WgkM r QM_5DiuUgm ■ MuseryeC r gyp r pestoresOL ■ P-g WIS ■ HQM4 ■ Help Locator Map -I- Map Size: 600 x 450 Functions G, Zoom In ('• 1 Zoom Out + Pan Identify Select 1,) Add EO Coordinates ' Query Database XClear Selection Quick View --Choose Region— PCQhl4m-.S_Or RuC9t60�57 http;//nhpweb.enr.state.nc.us/nhis/partner/gmap75_main.phtmI?grp_eo_py=Y&grp—eosrc_... 4/23/2010 DIVISION OF WATER QUALM Clieaistry I a►ara4arT Ilcporll p'+h* Q++Ph SAIIfPiE TYPE l.ab N.mber . [?ate Receired Tver Receiard RIVER BAIW4: jt' t E j AMEMNT QA --wcM ,�,( j/y EFFUUF 4T ileused By RFXORT TO RAf-i { Regional OS1x WE I'trt2wi,f �Le.'/711JA. CHAIN OF CUSM I-aKF EI DWLUEN8 Od6w n J [[ L ❑ MAEROENCY 1 VISrr 1D El LSTitARY Data Rekaxd = COLLECTOR(S) : A.. f I1 hole Reported &AT e C G[ fJoo3Sti.J 16doatedBODRaag-. Slal:r8aedtl.e: Srcd: Ra"Akr: Q. 0 rLT__1_"` zz..P�'� Cklawlaalyd: Slatian WIAK fiso Cade Pate l"f I Pale Bad lamf Tire Titnr End Deptk - DR4, PB, DIEM Valor Type _ A. H, L Cmpsito-T, S, B Sample T 0036P 0 s o =� �� BOD 310 mall. COD IL* 340 _WI_ COD Lma 115 awL Coldbrm- M1F Fcud 3) 616 /loom[ Colifetm' MF ToW 31504 1100" Cdifom- rube Fecal 31615 /100m1 Caldmm Fecal 3tucp 31673 /I00nd R4idur Total 500 met, Voladc S05 _9L Fund 510 tTWU ResAw. Salpeaded 530 _W1, Ynlnnk 515 mgJL Feed 540 n{jL pH e03 unds Acidity to pH 4,5 436 1OpJ•l. Aridity 10 pH L3 435 mlp'f. Alialmuy to pH 8 3 415 MdL Alkalinity to pH A 5 410 _9fL 7OC 690 myL N'l Tmbid" 76 U00ClifolmTaal oTube Moral cal ., 94o t1�L II a EPA445.0 modified option U^ Cale.: T ue 90 C a Cater -(pH) 83 PIT= tu, Gina[- pH 7 6 82 e.u. Cyanide 720 u1�L Fhmn Ae 951 en8r1- FumWelelgde 71890 mg/L C e and Oi11556 mgfL Hardness vow 9W Sp,C Cond. 95 0um0✓ran MBM 38260 ra}fL Phenols 32730 ug/L S0lfatr 945 owl-_ -QAkl&r 745 ME BMM Tearm & Ci pi. u87. Hrsawlau Chtarllium uplL 8rarbonne !*L vbeer>ar m,ldl- em1 DiuoErad Solids mg/1- 141-0nN610 TM an N 62.5 Np2 phn NO3 as N 630 myJL P. Toeal an P $65 mg/I- PO4 as P 70507 F*q- P. Disiolttd as P 666 mg/4 iC-Pnt:�uur UVIL Cd- Cad ­as m 1077 u�L Cr4lramiam.Tala11034 u8J1, Cu- Capper 1047 WMackel t067 u®1 Pb- Lased I M u8lF_ Z» znw 1092 ag1L V-Vag& m usaL AS- Silver 1077 uWL AI-Allmsinum 1105 aSfL Be- Beryllium 1012 at/I. Ca- Crleium 916 Co- Cob1i1 1037 u&FL Fe-1ma 1045 WA Mo-Mlolybdemmni aWL 1-Anita n ua/L Sn-Tm -Tball um rprL TwT.xam, uwL [HkF631 dart, run Li -Lithium 1132 uf/L Me. M ngrasum 427 emdl.. MrrM>ugst w i 055 ug[L Na• Sodium 929 t*L AnamwTota11002 va Se. Selrnmm 1147 uWL Hg Maculy 719w %,L B-Ballum dwl, ides Q kilo Orppe fimgp, Pes<"m Acid Habeidee Br.dNenntr+llAeid £tlratlable Organics TPH Diced Ramge PwBmble Ot# mf (VOA bottle req'd) TPHrBTFJI CIa1r111M Rang P6yt0pl.M. Teinpciaure om arrinl (�C'} Reported by ------ cNwpttt2(aburarory Sample ID- A&44308 Checked by UB flnof)trrLdRcpm Supervisor Reviewed by Sample Matrix_ WASTEWATER Lrnergency YewNo COG Ye!vMo Date S # Analyto Name PQL Result QuIlfirer Un[ti CAS ✓M Ana" Name PQL Result QualOw UnRs Sample temperature at receipt by 1.9 C , deported by Checked by Reviewed by ` _4&VTNt4� Ld5orcf6ry IVLT _B-dyimfRq-,i Sample 10: AB41508 Supervisor Date Sample Matrix: WASTEWATER Emergency Yes/No COG YeaMo AS # Analyte Name I M Result Qualifier Units GAS 9 Analyte Name PQL Result Quaker Units Total Dissolved Solids in liquid 12 12 165 m91L Chloride 1 1 9.6 J8 mgrL Flootide 1 0.4 0.4 U,J8 m9/L Ion Chromatography 1 TITLE_ -QIL Sulfate 1 2 54 J8 mg1L Reported by Checked by Reviewed by ,F.;�7VM9Q_Gaborarory Sample ID. A134"! VOT avafylital F[rpmt Supervisor Sample Matrix. WASTEWATER Emergency YestNo COC Yes/No Date AS Analyte Name PQL Result Qualifier Units CAS A Anatyts Name PQL Resuff Qualifier Units NH3 as N in liquid 0.02 0.02 0.06 XVL as I Total Kjeldahl N as N in tiquid 0.2 0.2 OA7 ig& as I NO2+11O3 as N In liquid 0.02 0.02 0.05 ig1L as I Phosphorus_t W as P in liquid 0.02 0.02 O-W WL as ~Iw I Reported by Checked by Revkv.ed by Sample Matrix: WASTEWATER Emergency Yes1No 'PVR�La6oratwy Sample ID- AB44500 :kE? �7nufyruul*Pirr SuPennsor Date CDC Yea1No I-fiS 0 Ana" 4Mame PqL Result Quallfrer Unit CAS N Analyte Name POL Result Qualifier Units 7440-22-4 E9:WPMS 5.0 5 5. U '"" ug/L , .(7'a,j 1 �• & ,PLA414. - • 00 1 t� ) 7429430-5 Al by ICP So 50 5 ugA- `!SP-3/1 7440-38-2 As by ICPMS 20 2 0.1.7.0 u9& 3 7429-WS a by ICP 5o 50 65 ug/L �-- - L yyWOA'1k O- 7440-38-3 Ba by ICP 10 10 21 Uw1_ 1 7440-41-7 Be by ICP 5.0 5 a 4r 5,0 U ug/L r 1 1440-70-2 Ca by ICP 0.10 D-1 38 nxyL T 7444-43.9 C ICPMS 1.0 1 u9& - pot �4'' 7440-48�1 IGP by IC S So 10 So 10 VIS u$tL037440-47-3 ug/L _ t7 I 7440-50-8 ICPMS 2.0 2 ug/L 743s- " Fe by ICP 50 50 420 ug1L 7439-97-6 g 2 .1 0.2 0.2 0.20 U91L . + r O t 2 7440 09-7 y ICP 0.10 0,1 �2.8 m9/L 7439-93-2 Li ICP 25 25 25 U ug/L 7439-95-4 Mg by ICP 0.10 0-1 1.7 mWL 7439-9&5 Mn by ICP 10 10 34 U91L 743MB-7 MO by ICPMS 10 10 10 U ugA- 7440-23-5 Na by ICP 0.10 0.1 7.2 - mglL 7440-02-0 Nf by ICPMS 10 10 10 U ug& 7439-92-1 Pb by ICPMS 10 10 10 U ug1L 7440-3" Sb by ICPMS 10 10 10 U ug1L 7782-49-2 Se by 4CPMS 5.0 5 5.0 U ug/L 7440-31-5 Sn by ICPMS 10 10 10 U ug/L 7440-28-0 Thallium (TI) ICPMS 10 10 10 U U91L 7440-32-6 Ti (Titanium) by ICP 10 10 10 U ugA. 744"2-2 V by ICP 25 25 25 U uglL 7440-6" Zn by ICPMS 10 10 10• z1 ug/L 11 Reported by A At,Qi Cabnrdg,r Sample ID: A641`,d8 Cherked by ;1tE �7nafy[:<a(�[poti Supervisor Reviewed by Cate Sample Mabuc: WASTEWATER Emetgencj YewWo COC YeSlNo S k Ana" Name PQL Result Qualifier Units CAS Y Ana" Nams PQL Result Qualifier llnfta United States Environmental Protectlon agency Form Approved, EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yrlmolday Inspection Type Inspector Fac Type 1 U N 2 I SI 31 NCS000350 111 12j 07/03/08 117 181 nl 191 .ct 201 I LJ �J I LJ LJ iJ Remarks 21111111111111111111111111111111111111111111111116 Inspection Work Days Facility Self -Monitoring Evaluation Rating 131 QA --------------------------- Reserved ---------------------- 67I 169 70I u I 71 I tyk 72 73 LL 74 751 11` I I I 180 t� Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also Include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 10;00 AM 07/03/08 02;05/01 Edgecortcbe Genco, LLC-Battleboro Exit Time/Date Permit Expiration Date 6358 Old Battleboro Rd aattleboro NC 27809 12;00 PM 07/03/06 07,104/30 Name($) of Onsite Representative(s)fritles(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible Official/Tibe/Phone and Fax Number Contacted Seth Carter,PO Box 370 Battleboro NC 27809//252-442-0805/ No Section C: Areas Evaluated During Inspection Check only those areas evaluated Storm Water Section D: Summary of Findin /Comments Attach additional sheets of narrative and checklists as necessa (See attachment summary) Name(s) and Signature(s) of Inspectors) Agency/Office/Phone and Fax Numbers Date Ran Boone RRO WQ//704-663-1699 Ext.2202/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560.3 (Rev 9-94) Previous editions are obsolete. Page # 1 NPOES yrlmo/day Inspection Type 3I NCS000350 I11 121 07/03/08 +17 18fC (cont. ) Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) SP3 has been developed and implemented. Qualitative monitoring being done more often than required. However, permittee must ensure that even though its being done more often than needed, it still must be done at least twice per during the timeframes specified in the permit, i.e. spring - Apr through ,tune and fall - Sep through Nov. Also, permittee is not conducting analytical monitoring because they have a SW detention pond that they assert meets the criteria of footnote #2 of table #1, Analytical Monitoring Requirements, in Part II, Section B of the permit, i.e. the stormwater "...detention pond discharges only in response to a storm event exceeding a ten yar design storm...". However, the pond was discharging at the time of the inspection through an orifice in the side of the overflow pipe that was placed approximately 12" to 24" below the overflow level of the overflow pipe. According to Cogentrix personnel and their engineer, the orifice is the mechanism by which the level of the pond is kept at the level required for the pond to contain the 10-year design storm without overflowing at the overflow pipe. This is still considered a discharge that must be monitored in accordance with table #1. Finally, the above mentioned pond was discharging during the inspection despite that fact that it was not raining and hadn't rained for quite some time prior to the inspection. This strongly indicates one or more unidentified, unauthorized, illicit wastewater discharges through the SW detention pond. The permittee must immediately undertake to identify all discharges into the pond and stop them and/or have them appropriately permitted. 05/07/2007, RCB, Reviewed NOV at permittee's request. NOV rescinded because it was initially issued for failure to perform analytical monitoring as required. However, this inspection was conducted in year five of the permit, which requires no analyticals. Once I saw the discharge from the orifice in the standpipe, I assumed the orifice had been there all along (i.e. in previous years) and that they were discharging the whole time. But the permittee stated that they had not been discharging prior to 10/06 and that the orifice was not placed in the standpipe until 10/06 and that's why they had never done any analyticals until now. So, at Chuck Wakild agreement, the NOV was rescinded and will be deleted. Page # 2 Permit: NCS000350 SOC: County: Edgecombe Region: Raleigh Compliance Inspection Report Effective: 05/01/02 Expiration: 04/30/07 Owner: Edgecombe Genco LLC Effective: Expiration: Facility: Edgecombe Genco, LLC-Battleboro 6358 Old Battleboro Rd Contact Person: Seth Carter Title: Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Re presentative(s): Related Permits: Inspection Date: 05/20/2009 Entry Time: 09:30 AM Primary Inspector: David R Parnell Secondary Inspector(s): Autumn Hoban Reason for Inspection: Routine Permit Inspection Type: Stormwater Discharge, Individual Facility Status: ❑ Compliant ■ Not Compliant Question Areas: 0 Storm water (See attachment summary) Battleboro NC 27809 Phone: 252-442-0805 Certification: Exit Time: 03:00 PM Phone: Phone: 919-791-4260 Phone: Inspection Type: Compliance Evaluation Page: 1 Permit: NCS000350 Owner - Facility: Edgecombe Genco LLC Inspection Late: 05/20/2009 Inspection Type: Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? ■ ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? ■ ❑ ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? ■ ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? ■ ❑ ❑ Cl # Does the Plan include a list of significant spills occurring during the past 3 years? ■ ❑ ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? ■ ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? ■ ❑ ❑ ❑ # Does the Plan include a BMP summary? ■ ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ■ ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ■ ❑ ❑ ❑ # Does the facility provide and document Employee Training? ■ ❑ ❑ ❑ # Does the Plan include a list of Responsible Party(s)? ■ ❑ Cl ❑ # Is the Plan reviewed and updated annually? ■ ❑ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? i ■ ❑ Cl ❑ Has the Stormwater Pollution Prevention Plan been implemented? ■ ❑ ❑ ❑ Comment: Secondary containment adequate. Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ■ ❑ ❑ ❑ Comment: Adequate qualitative monitoring Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ❑ ■ ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ ■ ❑ Comment: Continuous discharging stormwater pond requires sampling. No analytical monitoring data available. Recommend measuring sediment in stormwater pond. Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? ■ ❑ ❑ ❑ # Were all outfalls observed during the inspection? ■ ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ■ ❑ ❑ ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ■ ❑ ❑ ❑ Comment: Plant refers to SDO 001, DWQ refers to it as 005 Page; 3 .ir re United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 6-31-98 Section A: National Data System Coding (Le., PCS) Transaction Code NPDES �-, Jyr/mo/day Inspection Type Inspector Fac Type 1 I NI 2 1 51 31 NCO077437 111 121l 09/05/20 117 is Cl 191 cl 20I ' IJ LJ LJ L l U Remarks 21111111111111111111111111111111111111111111111116 Inspection Work Days Facility Self -Monitoring Evaivation Rating 131 QA --------------------------- Reserved ---------•------------ 671 169 70 LI 71 LI 721 1 73 W 74 751 1 1 1 1 1 Li 80 �J LJ Section i FacilityData Name and Location of Facility Inspected (For Industriai Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 09:30 AM 09/05/20 05/07/01 Batt_eboro oiant Exit Time/Date Permit Expiration Date 6358 Oid Battieboro Rd Battleboro NC 27609 04:00 PM 09/05/20 09/_0/31 Names) of Onsite Representative(s)Mtles(s)/Phone and Fax Number(s) Other Facility Data David Lee Herring/ORC/252-442-0805/ Name, Address of Responsible Ofcialrfitle/Phone and Fax Number Contacted Sid rynyer,PO Box 370 Battieboro NC 27809//252-442-0805/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated Permit 0 Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program Sludge Handling Disposal Facility Site Review Compliance Schedules Effluent/Receiving Waters Laboratory Section D: Summary of Find in/Comments Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Names) and Signature(s) of Inspectors) Agency/Office/Phone anC, Autumn Hoban RRO WQ/// �t�' � } y� 6. Y r David R ?arncll RRO ttiQ//919-791-4.. ��'^n�t �,� NM(/y�' +✓(�. •, I' Signature of Management Q A Reviewer Agency/OfficelPhone and l jr EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. NPOES yrlmo/day Inspection Type 3I NC0077437 I11 121 09/03/20 E 17 18Li Section D: Summary of FindinglComments (Attach additional sheets of narrative and checklists as necessary) This facility has FGD wastewater that is evaporated in a open cement pit close to the main building with solids being removed as needed and handled by Full Circle Solutions. DMR review shows issues with Toxcity- High Zn at outfall 003. Issues with flow- recycle CT water for use at the scrubbers, so all wastewater now discharges out outfall 003. This likely concentrates pollutants and has made it more difficult to meet limits with regards to Zn. A Reverse Osmosis unit discharges reject water to the cooling tower basin. So same comment as above, when can no longer recycle they are still permitted to discharge cooling water that has been recycled and concentrated through re -use practices to their wastewater basins, RRO conducted sampling to review outfall 003 discharge in light of these operational changes to provide more information to the Permitting Unit for the Permit renewal coming up. The sample results showed the following concerns: Wastewater Discharge Outfall 003: Sulfate = 270 mg/L, Boron = 85 ug/L, Cu = 18 ug/L, Mo = 45 ug/L, Zn = 53 ug/L The sampling also revealed some concerns with the stormwater: NCS000350 Stormwater Discharge Outfall: Aluminum = 510 ug/L, Arsenic = 7 ug/L, Boron = 65 ug/L, Zinc = 21 ug/L Page # 2 .�1 Permit: NCO077437 Owner -Facility: Battleboro plant Inspection Date: 05/20/2009 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? ■ ❑ ❑ ❑ Is the facility as described in the permit? ❑ ■ ❑ ❑ # Are there any special conditions for the permit? ❑ ❑ ■ ❑ Is access to the plant site restricted to the general public? ■ ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ■ ❑ ❑ ❑ Comment: The permit application was received April 3, 2009. The facility has a Reverse Osmosis Unit that discharges reject water to the cooling tower. Water used in cooling as well as reject water from the RO unit (can be discharged) when needed through the permitted wastewater outfall. No information regarding the RO unit reject water was provided in the application. Also some condensate comes back from Hospira (next door) that can be re -used or re-routed to the cooling tower, again until the cooling tower is purged, and then at that point, discharges to the permitted wastewater outfall. Compliance Schedules Yes No NA NE Is there a compliance schedule for this facility? Cl ❑ ■ ❑ Is the facility compliant with the permit and conditions for the review period? ❑ ❑ ■ ❑ Comment: Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ■ Cl ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge ■ ❑ ❑ ❑ Judge, and other that are applicable? Comment: Pump Station - Effluent Yes No NA NE Is the pump wet well free of bypass lines or structures? ■ ❑ ❑ ❑ Are all pumps present? ■ ❑ ❑ ❑ Are all pumps operable? ■ ❑ ❑ ❑ Are float controls operable? ■ ❑ ❑ ❑ Is SCADA telemetry available and operational? ❑ ❑ ❑ ■ Is audible and visual alarm available and operational? ❑ ❑ ❑ ■ Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? ■ ❑ ❑ ❑ Page # 3 r , Permit: NCO077437 Owner - Facility: Battleboro plant Inspection Date: 0512012009 Inspection Type: Compliance Evaluation Flow Measurement - Effluent Yes No NA NE Is flow meter calibrated annually? ■ ❑ ❑ ❑ Is the flow meter operational? ■ ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ ❑ ■ Comment: Flow measurement consists of a 9' parshall flume and ISCO flowmeter that was last calibrated December 29, 2008. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ■ ❑ ❑ ❑ Is sample collected below all treatment units? ■ ❑ ❑ ❑ Is proper volume collected? ■ ❑ ❑ ❑ is the tubing clean? ■ ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? ■ ❑ ❑ ❑ Is the facility sampling performed as required by the permit (frequency, sampling type representative)? ■ ❑ ❑ ❑ Comment: DMR's for 2007 and 2008 showed elevated levels of zinc at outfall 003. Samples were not taken in 2007 and 2008 at outfall 002, the facility reported no flow at 002 during that time period. Results of outfall 003 sampling event during the inspection are on the summary page of this inspection report. Solids Handling Equipment Yes No NA N Is the equipment operational? n n ■ n Is the chemical feed equipment operational? ❑ ❑ ■ ❑ Is storage adequate? ❑ ❑ ■ ❑ Is the site free of high level of solids in filtrate from filter presses or vacuum filters? ❑ ❑ ■ ❑ Is the site free of sludge buildup on belts and/or rollers of filter press? ❑ ❑ ■ ❑ Is the site free of excessive moisture in belt filter press sludge cake? ❑ ❑ ■ ❑ The facility has an approved sludge management plan? ❑ ❑ ■ ❑ Page # 4 Permit: NC0077437 Inspection Date: 05/20/2009 Owner -Facility. Battlebora plant Inspection Type: Compliance Evaluation Solids Handling Equipmenk Yea No NA n Comment: A copy of the Sludge management plan was collected for the file. The facility has a pugmill and silo for dry fly ash handling. Full Circle Soln's land applies fly ash solid waste. ****FGD system -Evaporates wet FGD wastewater- this water is sometimes exposed to the driveway( torm rains) where it is located (depending on evaporation rates/water leve s and the solids are removed and land applied by Full Circle solns as stated above. The facility removes solids from the Wastewater basins and the solids are hauled off to the Sampson Co Landfill twice per year. Equalization Basins Yes NO NA Nt Is the basin aerated? ■ ❑ ❑ ❑ Is the basin free of bypass lines or structures to the natural environment? ■ ❑ ❑ ❑ Is the basin free of excessive grease? ■ ❑ ❑ ❑ Are all pumps present? ■ ❑ ❑ ❑ Are all pumps operable? ■ ❑ ❑ ❑ Are float controls operable? ■ ❑ ❑ ❑ Are audible and visual alarms operable? ■ ❑ ❑ ❑ # is basin sizelvolume adequate? ❑ ❑ ❑ ■ Comment: Facility has duel Cement Wastewater Settling Basins.Ph adjust effluent as needed with sodium hydroxide or sulfuric acid. Chemical Feed Yes No NA NE Is containment adequate? ■ ❑ ❑ ❑ Is storage adequate? ■ ❑ ❑ ❑ Are backup pumps available? ❑ ❑ ❑ ■ Is the site free of excessive leaking? ❑ ❑ ❑ ■ Comment: Sulfuric acid and sodium hydroxide fed to effluent as needed. Nutrient Removal Yes No NA NE # Is total nitrogen removal required? ❑ ❑ ■ ❑ # Is total phosphorous removal required? ❑ ❑ ■ ❑ Type # Is chemical feed required to sustain process? ❑ ❑ ■ ❑ Page # 5 permit: N00077437 Inspection Date: 05120/2009 Owner - Facility: Battleboro plant Inspection Type: Compliance Evaluation Nutrient Removal Yes No NA NE Is nutrient removal process operating properly? ❑ Cl ■ ❑ Comment: Only Total Phosphorus is in the permit. I did not see ferric on -site for removal of Phosphorus, but did run nutrients and the results are in the summary of the inspection. This facility does discharge to NSW- Tar River. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? ❑ ❑ ❑ E Are the receiving water free of foam other than trace amounts and other debris? ❑ ❑ ❑ ■ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ ❑ ■ . r I Comment: The effluent pipe is an 8 inch forcemain to the Tar River approx. 5 miles from the site. Effluent samples were taken in the wet well prior to leaving the plant site. The final outfall of the effluent pipe was not viewed the day of the inspection. Upstream / Downstream Sampling Yes No NA NE Is the facility sampling performed as required by the permit (frequency, sampling type, and sampling location)? ❑ ❑ ■ ❑ Comment: No upstream downstream sampling required by the permit. Disinfection -Liquid Yes No NA NE Is there adequate reserve supply of disinfectant? ❑ ❑ ■ ❑ (Sodium Hypochlorite) Is pump feed system operational? ❑ ❑ ■ ❑ Is bulk storage tank containment area adequate? (free of leaks/open drains) ❑ ❑ ■ ❑ Is the level of chlorine residua! acceptable? ❑ n ■ n Is the contact chamber free of growth, or sludge buildup? ❑ ❑ ■ ❑ Is there chiorine residual prior to de -chlorination? ❑ Cl ■ ❑ Comment: City water is used for makeup water in the plant. The city water contains Chloramines. The facility does not add additional chlorine. De -chlorination Yes No NA NE Type of system ? Liquid Is the feed ratio proportional to chlorine amount (1 to 1)? Cl ❑ ❑ ■ Is storage appropriate for cylinders? ■ ❑ ❑ ❑ # Is de -chlorination substance stored away from chlorine containers? ■ ❑ ❑ ❑ Are the tablets the proper size and type? ❑ ❑ ■ ❑ Comment: Maybe overfeeding dechlor-based on chemical readings of the effluent the day of the inspection, Are tablet de -chlorinators operational? ❑ ❑ ■ ❑ Page # 6 Permit: N00077437 Owner -Facility: Sattleboro plant Inspection Date: 05120I2008 Inspection Type: Compliance Evaluation ran-d-hinrinn+inn Yes No NA NE Number of tubes in use? Comment: Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? ■ ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? ■ ❑ ❑ ❑ # Is the facility using a contract lab? ■ ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? ■ ❑ ❑ ❑ Incubator (Fecal Coliform) set to 44,5 degrees Celsius+/- 0.2 degrees? ❑ ❑ ■ ❑ Incubator (800) set to 20,0 degrees Celsius +1- 1,0 degrees? ❑ ❑ ■ ❑ Comment: Lab -James R Reed and Associates Lab certified in NC and VA Facility holds field parameter certification #5287. ORC- Sandy Bunn PC-1 Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ■ ❑ ❑ ❑ Is all required information readily available, compiete and current? ■ ❑ ❑ ❑ Are all records maintained for 3 years (lab, reg, required 5 years)? IN ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? ■ ❑ ❑ ❑ Is the chain -of -custody complete? ■ ❑ ❑ ❑ Dates, times and location of sampling ❑ Name of individual performing the sampling ❑ Results of analysis and calibration ❑ Dates of analysis ❑ Name of person performing analyses ❑ Transported CM ❑ Are DMRs complete: do they include all permit parameters? ■ ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ■ ❑ ❑ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 2417 with a certified operator on each shift? ■ ❑ ❑ ❑ Is the ORC visitation log available and current? ■ ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ■ ❑ ❑ ❑ Page # 7 Permit: NC0077437 Owner • Facility: Battleboro plant Inspection Date: 05/20/2009 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Is the backup operator certified at one grade less or greater than the facility classification? ■ O ❑ ❑ Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? Comment: ■000 Page # 8 1 r•� D"ION OF WATER QUALITY CFeesiatt7 Laboratory RgmA J Water Quality SAMPI Lnn SJOiFN7Y � }:l r/ PIU� RIVER DASIL4: AIHBMNT QA MKF-.M I]CI PYFLUFW REPORT TO 0 S Reponal ORioe ,JSJ COMPL IAM-F ❑ OWN OF CUSTODY LU:£ ❑ INF3_UENT f,e r;4o„ f fzr.aFwrZ OKer EMERGENCY WSW ID h.'SfLIARY COLLECTOR(S) :�14 _ 12, `��'YL�J}t? l E.ab N..ber Ebte Rccetx:d Time Raii.ed Rzcc,led By Dda Relea Dw. Rcponcd T (Y FN N n Esfma" ROD R.0c.: Slation Lxatian: p 43,'w Seed: �� Cklarinued: Rem.ha: _-J.g—'S �PC� dh+ Saban fl!Lacafi oo Code Dale (yyfo dd) Date kad (yytr- Tlee Relax iLme Fvd DepeY - D.'1t, D$, UR►! Vahe Typr -.4, H, L Cowpwk -T, S, B c.Mpk Type r p < o S ;3� HOD 3 t0 mp/L t sD nO 340 MWL. COD low 33 5 fl*L Cdifo MF Fecal 31616 llfgml Conform: MF TOW 31504 - 1100nd CGhlieln- tube Fed 3 16 t 5 /100e,1 Colifwm Fecal Strep 31673 iloDrd R4 dac Tu1.1 500 MeL Yutatdc S05 mg'L Hoed 510 -wL- Resduc Su Spcnded 510 -Og L Yolalde 515 mg•L Fued 540 -W'L pF1403 um" Acidity 10 pH 5 436 mw3. Acidity to pH It 3 435 -JVL Atkahn.q to pH R,3 415 t:*(L AlWieny 1. pH 4 5 410 tr4s1L TOC 680 -.WL Twbidn 76 MU Culifinm Taal Tube 1100 ml Cbla.tde 940 maJL Chlamph70 a EPA 445 0 ntodlftcd option ugyL Calm: Tree 90 an. Calor:(PH) X3 PW c.u, CaiorpH7.6 82 C. Cymidc 720 mg/L Fleonde 951 nlgji. Fatanldchyde7113O mF/L C c and Oils 5% Herda Twirl 900 -9(L Spo ific Cond_ 95 umhoskm MDAS 38260 MIL Phenols 32730 - Salfate 945 a�7. Sulfide 745 me'L Domn 1'amm St Limn nS(L 1}.rdrnt Chroeuten ug7_ Aitzbmale wkwL CwtcA le trwL TO1a1 Dcudwd SOw, .81L Reported by Checked by Reviewed by 'F91'7 D%iW Lalxnatory Semple ID: AB44507 �:38 �nafytiral7(eFrort Supervisor Sample Matrix: WASTEWATER Emergerscy YeslNo COC YeslNo Date AS 0 Analyte Name PQL Result QuatlBer tJnits CAS R Analyto Name PQL Result Qualifier Units Sample lemperature at receipt by 1.9 'C Reported by Sample ID, 'EA%�,La6oraimy Checked by Sl]PeNI40i Reviewed by Date ASM1507 Sample Matnx- WASTEWATER Emergency Yes1N0 CDC Yes1No q Analyte Name PQL Resuft Qualifier Unft CAS # Analyte Name PQL Rssldt Qualifier Un is Cherrdcal Oxygen Demand in liqui 20 2D 35 mg1L Total Dissolved Solids in liquid 12 12 684 mgfL Chloride 1 1 - 58 J8 ngtL Fluoride 1 0,4 4.0 if P J8 mWL Ion Chromatography 1 TITLE_ mgfL Sulfate 1 2 270 J8 mg1L Reported bv Sample ID: AB41507 'E"�'�Dtt'r2 LaSora tory Checked b]t Y17 Tnafytica(4�!pcf Supervisor — Reviewed by Gate Sample Mlatax: WASTEWATER Emergency YeVNo CDC Yes/No S i Analybe Name POL Result QU3M@F Units CAS q Analyte Name PQL Result QUdlfie► Units NH3 as N in liquid 0.02 0.02 0.02 U )glL as I Total Kfeklahl N as N in liquid 0.2 0.2 0.75 7Q& as l NO2+NO3 as N in &quid 0.02 0.02 2.0 IA as 1 Phosphorus —total as P in liquid 0.02 0.02 2.2 V/L as Reported by Cha*ed by Rer—v , '71-qVDft4ZC4Sanlfo y !OFT 7MdytrcAf xirt Sample ID: Supennsor A844607 bf' Date Sample Matrix: WASTEWATER Emergency Yes/No CQC YcVNo FAS It Analyte Name PQL Result Qualifier Units CAS # Ana" Marra PQL ResuR Qualifier Unit 7440-22-4 Ag by ICPMS 5.0 5 5.0 U ugtt 7429-90-5 Al by ICP 50 SO 54 ug1L 7440 3&2 As by furnace 20 2 2.0 U ug/L 7429-90-5 B by ICP 50 50 85 ugA 7440-38-3 Ba by ICP 10 10 66 ug/L 7440-0I-7 Be by ICP 5.0 5 5.0 U U91L 7440-7Q2 Ca by ICP 0.10 0,1 46 mplL 7440-43-9 Cd by ICPMS 1.0 1 1.0 U U91L 744D48.4 Cobalt by lCP 50 50 50 U uglL 744047-3 Cr by ICPMS 10 10 1 D U uglL 7440-50.8 Cu by ICPM5 20 2 16 ug/L 7439-SM Fe by ICP 50 50 230 vglL 7439-97-8 Hg 245.1 0.2 0.2 0.20 U uglL 7440-09-7 K by ICP 0.10 0.1 9.3 mg1L 7439-93-2 Li ICP 25 25 25 U ug/L 7439-95-4 Mg by ICP 0.10 0.1 8.2 mg1L 7439.9&5 Mn by ICP 10 10 19 ugA- 7439.9&7 MobylCPMS 1D 10 45 ug& 7440.23.5 Na by ICP 0.10 0.1 160 "KA 7440-02-0 M by ICPMS 1D 10 10 U ugfL 7439-92-1 Pb by ICPM5 ID 10 10 U ug1L 744048-0 5b by ICPMS 10 10 10 U ug/L 778249.2 Se by furnace 5.0 5 5.0 u ug/L 7440-31-5 So by ICPMS ID 10 10 U u911- 7440-28-0 Thalbum (fl) ICPMS 10 10 10 U uglL 7440-32-6 Ti (Titanium) by ICP 10 10 10 U u91L 7440-62-2 V by ICP 25 25 25 U uglL 7440-66-6 Zn by tCPMS 10 10 53 U91L Jones, .!ennifer From: Parnell, David Sent: Wednesday, February 17, 2010 10:39 AM To: Corporon, Joe; Jones, Jennifer; Romanski, Autumn Subject: RE: Cogentrix (Edgecombe Genco LLC) NC0077437 Joe and ten, Autumn and I can work on a staff report for you and schedule a visit to the facility (would have to be after March I — and schedule is tight even then). We could probably schedule a visit in a half day time frame. What is your timeline for issuance of the permits? The Stormwater Permit number is NCS000350, you can locate the Stormwater inspection report in BIMS from May 20, 2009. Keep me informed as to what you are needing from RRO. Thanks, Dave Parnell 791,4260 From: Corporon, Joe Sent: Wednesday, February 17, 2010 7:04 AM To: ]ones, Jennifer; Romanski, Autumn Cc: Parnell, David; Herzberg, Barry Subject: RE: Cogentrix (Edgecombe Genco LLC) NC0077437 Confirmed - I am the assigned Permit Writer. Sorry for the slow response, ya'll (burried under some problem renewals), Edgcombe has yet to surface from my pile of folders. • Have not yet located the Stormwater inspection report. • A Staff Report might be prident - help me clarify their current conditions and proposed system changes. • Sounds like I should join a site visit for this one - let's discuss. Out of the office today (but monitoring email) - back in Thur and Fri. From: ]ones, Jennifer Sent: Friday, February 12, 2010 3:20 PM To: Romanski, Autumn; Corporon, Joe Cc: Parnell, David; Herzberg, Barry; Jones, Jennifer Subject: RE: Cogentrix (Edgecombe Genco LLC) NCO077437 Hi Autumn, Thanks for the data. I do have the stormwater permit renewal in my office. Just have not had a chance to get to it... rrrr.... I'm really sorry = there is just so much to do! Arg. Joe I would like to work with you — we should get together on discussing outfalls and on writing both permits — looks like there are some concerns here and also that they are having some "continuous discharge" from their SW outfalls? Dave — I'm in the office right now. Give me another call or let me know by email info you have for me -- email might be better because I can keep on file then- -- I am assuming you want to talk about this? "The sampling also revealed some concerns with the stormwater: NCS000350 Stormwater Discharge Outfall: Aluminum = 510 ug/L, Arsenic = 7 ug/L, Boron = 65 ug/L, Zinc = 21 ug/L" Yikes. Thanks for cc'ing me Autumn and giving me a call Dave. Jen Jennifer Jones Environmental Engineer NCDENR I DWQ I Stormwater Permitting Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 512 N. Salisbury St, Raleigh, NC 27604 Phone: (919) 807-6379 Fax: (919) 807-6494 Email: jennifer.iones(a)ncdenr.eov Website: http://Portal.ncdenr.orp,/web[wq/ws/su **E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third .►J parties.** From: Romanski, Autumn Sent: Friday, February 12, 2010 2:41 PM To: Corporon, Joe Cc: Parnell, David; Jones, Jennifer; Herzberg, Barry Subject: FW: Cogentrix (Edgecombe Genco LLC) NCO077437 Joe, Can you let Dave Parnell and myself know who is working on the Genco Co Gen power plant renewal? NCO077437 Attached please find a copy of the fast inspection done in May 2009. Sampling was conducted and findings of concern were listed with the result in the summary section of the inspection. We would like the permit writer to review prior to renewing the permit. If you need a complete staff report on this one, please let me know. Preliminary Sample results are also attached and final QA/QC copies are available from the lab. No changes were made to the findings after the preliminary results were posted on lab works. Jennifer Jones may also be interested in the stormwater sampling results in relation to the permittee's NCS000350 stormwater permit, so I have copied her as well. Sincerely, Autumn From: Herzberg, Barry Sent: Thursday, February 11, 2010 11:26 AM To: Corporon, Joe Cc: Romanski, Autumn; Smith, Danny Subject: Cogentrix (Edgecombe Genco LLC) NCO077437 Joe, I got a call from these folks this morning. They wanted status of their permit renewal. Maybe you could call Cheryl Sawyer at 757-238-9571 with an update. 3 Also, as an FYI, they'll be looking for advice as to possible changes in the permit due to a change in their ash handling. I told them they'd need an ATC as it sounds to me like a process change (going from dry ash to wet ash). I also gave them Autumn's name as our resident coal fired power plant expert. Barry E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. Barry Herzberg Environmental Engineer NCDENR - DWQ Raleigh Regional Office Voice 919-791-4249 Fax 919-788-7159 barry.herzberg@ncdenr.gov NC®EN� North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director 10.2.09 Mr. David Herring, Environmental Manager Cogentrix Edgecombe Genco, LLC P. O. Box 370 6358 Old Battleboro Road Battleboro, NC 27809 Subject: Compliance Evaluation Inspection NPOES Individual. Stormwater Permit%NCS000350 Cogentrix Edgecombe County. Dear Mr. Herring: Dee Freeman Secretary On May 20, 2009, Autumn Hoban and Dave Parnell of the Raleigh Regional Office of the Division of Water Quality, performed a compliance evaluation inspection (CEI) for the NPDES Individual Stormwater Permit at the subject site. Your assistance.was helpful. and appreciated. The following observations were noted during the Division of Water Quality inspection: . SITE DESCRIPTION This is a coal-fired power generation facility. All site stormwater flows into. a detention pond and is then discharged via one, stormwater discharge outall (SDO) located on the southern end of the site. The stormwater is discharged to receiving waters known as an unnamed tributary to Beech Branch, a Class C, nutrient sensitive water (NSW) in the Tar - Pamlico river basin. When corresponding with the Stormwater Permitting Unit, please . correct the stream name currently listed as Beech Creek to Beech' Branch. INSPECTION SUMMARY 1. The Individual Stormwater Permit expired on April 30, 2007 and the Stormwater Permitting Unit has not received an application for renewal. Please note that an application for renewal On e NhCarolina Avura!!y North Carolina Division of Water Quality Raleigh Regional Office Surface Water Protection Phone (919) 791-4200 Customer Service Internet: www,ncwaterquality.org 1628 Mail Service Center. Raleigh; NC 27699-1628 FAX (919) 788-7159 877-623.6748 An Equal Opportunity/Affirmative Action Employer — 50% Recycled710% Post Consumer Paper Cogentrix Energy, Inc. Compliance Evaluation Inspection is required 6 months prior to the expiration of.the permit. Neglecting to apply for the renewal of the permit is a violation of North Carolina General Statute 143-215.1. Please contact Jen Jones of the Stormwater Permitting Unit immediately at 919 807.6379, concerning the permit renewal process. 2. The Best Management Practices (BMP) plan was available during the CEI. The documented records of BMP inspections were reviewed and they were found to be in'order. 3. SDO 001 was visited during the inspection. As noted above, SDO 001 has continuous flow, and therefore, both qualitative and analytical monitoring is required. A documented record of the monitoring is required. If the flow is absent, the comment "no flow" should be entered on the monitoring report. Qualitative monitoring is currently being conducted at SDO 001, but analytical monitoring results were not produced. Please begin sampling the discharge from the stormwater pond immediately as required by your permit. There was some discrepancy in the SDO numbering shown on the SPPP plan (SDO 001) and DWQ records (SDO 005) which creates confusion. Please notify this office'of the correct SDO number. 4. SDO 001 was.sampled during the CEI. The following parameters were reported by the DWQ Chemistry Lab. Sample result for total recoverable Aluminum (Al) was 510 ug/L. The Iron (Fe) results were 420 ug/L. Please address and respond in writing to the above item; shown in bold, to this office, by September 15, 2009. If you have any questions regarding the attached report or any of the findings, please contact me at: (919) 791-4200 or email: david.i)arnell@ncddnr.gov. Sincerely, Dave Parnell Environmental Specialist Surface Water Protection Section Enclosure: May 20, 2009, Compliance Evaluation Inspection Cc RRO/SWP files DWQ Stormwater Permitting Unit . OCT 1 6 2009 EtlR Rr;LEA 2' .:,., VAgecombe«f .erten, l_l.C. _ — October 14, 2009 RO. N"-V 3ifj Ark L.ner % Nc; 6353 Old Niticl :wo Hamil garlcburiY,'NC 17909 Mr. Dave Parnell North Carolina Division of Water Quality Raleigh Regional Office 1 628 Mail Service Center Raleigh, NC 27699-1628 Subject: Response to Compliance Evaluation Inspection {CEI} dated 10.2.09 For Edgecombe Genco LLC, Storrs Water Permit NC5000350 Edgecombe County Dear Mr. Parnell: In regards to the CEI conducted by yourself and Autumn Hoban of the Raleigh Regional Office on May 20, 2009 for NPDES permit compliance, Edgecombe wishes to respond to three listed action items from the inspection Summary: The Individual Stormwater Permit expired on April 30, 2007 and the Stormwater Permilling Unit has not received an application for renewal. Please note that an application for renewal is required 6 months prior to the expiration of the permit. Neglecting to apply for the renewal of the permit is a violation of North Carolina General Statue 143-215-1.... Edgecombe Genco response: Edgecombe has on file (EHS 1.8.2) a copy of the permit renewal application submitted to NCDENR-DWQ on October 25, 2006. The permit application was submitted via certified mail. Attached to this letter are copies of the original submittal and of the certified mail receipt. ' 2. SDO 001 was visited during the inspection. As noted above,- SDO 001 has continuous flow, and therefore, both qualitative and analytical monitoring is required.... Qualitative monitoring is currently being conducted at SDO 001, but analytical monitoring results were not produced. Please begin sampling the discharge from the storm water pond Immediately as required by your permit. There was some discrepancy in the SDO numbering shown on the SPP plan (SDO 001) and DWQ mcords (SDO 005) which creates confusion. Please notify this office of the correct SDO number. Edgecombe Genco response: In regards to analytical testing of the Storm Water Outfall, our decision not to conduct the analytical portion was based on Section B; Analytical Monitoring Requirements Footnote 2 to Table I which says: • Page 2 October 15, 2009 Iif the storm water runoff is controlled by a stoma water detention pond, a grab sample of the discharge from the pond shall be collected within the first 30 minutes of discharge. if the detention pond discharges only in response to a storm event exceeding a ten year design storm, then no analytical monitoring is required and only qualitative monitoring shall be performed. A letter was submitted to Mr. Chuck Wakild of NCDENR-DW4 on March 16, 2007 detailing the specifics for our: determination that this pond was a storm water detention pond, and, therefore, exempt from the analytical monitoring required: by the permit. In Mr. Wakild's response dated April 30, 2007, while accepting,that the pond's status changed from a storm water detention pond to a wet detention pond with the addition of an orifice to release ground water collected by the pond, he stated the pond was NOT a storm water detention pond but a wet detention pond and analytical monitoring was required. However, at that point in time the.time period encompassed by the storm water permit had expired (April 30, 2006 was the latest time period covered for analytical monitoring). Based on Mr. Wakild's response, Edgecombe did pull. analytical samples from the storm water detention- pond discharge. These samples were analyzed for Total Suspended Solids and Chemical Oxygen Demand along with the specific rainfall event data. Edgecombe submitted these resufts to Central Files on three occasions dated: 04/16/07, 10/25/07, and 03/05/08. If those results cannot be found, we will resubmit them. Since seven sampling, events were required by the rives -expired 'permit, Edgecombe Genco will conduct four Trion- querterty sampling events to complete . -the. requirement, for SDO 5 (Stormwater Outfall 5) flow and rainfall permitting. The results of the analysis will be submitted to NCDENR-DWO once received. As indicated, we will designate this outfall as SDO 5. Once the new Stormwater Permit is issued, we will conduct all of the required monitoring per the hermit requirements. 3. Lastly, the now -expired permit listed the discharge location as Beech Creek and that is the terminology used in the narrative of our SPPP plan. However, based on your letter, we will change the description to Beech Branch. While your letter stated that we should respond by September 15, 2009, it seemed apparent that October 15, 2009 was the intended. response date since ,your letter was dated 10.2.09. Should you require any more information, please do not hesitate to contact me at: (252) 442-0708 oryla email (BillMaiden@Cogentrix.com). Regards, Bill Maiden General Manager, Edgecombe Geneo, LLC ' UWQ Laboratoly Section &sults County: F-DOECOMPE Sample ID. A944608 River Bases TA NA 7'F sf ti ro PO Number fe 9W4318 Report To RROSP r} f rR Date Received: OwS1r2t309 Collector: AA HpBAN I -. n� w,.�t•-' -.r��' .-4 Time Received: 06.15 Region RRO =i�i ' Labwortrs LoginlD SMATHIS Dave Reported` 7rti09 Sample Matrix; WASTEWATEf; Luc. Type: EFFt VENT Report Generated: M2912098 Ernergency YealNo � COO YeatNo 1las;lD cr 1,1101 Loc. Descr.: BAT C2,EN 003 SVJ / Location ID: BATCOGENO03SV1 Coifect'Dwe; OS120r2o09 Collect Time: 12:15 Sample Depth Sample Qualifiers and Comments Routine Qualifiers For a more detailed description of these qualifier codes rater to 1rnrrw.dwglab.org under Staff Access A -Value reported is the average of two or more detarmin2jons N3-Estimates concentration is < POL and >MDL 81-CovnYsWe membranes vrM <20 colonies; Estimated NE -No established a{}t, 132- Counts from 0 f'3tr t7 were Iero. 83-Countable membranes with more than 60 or 50 ooloniez; Estimated o-Etevated Pt7L due to matrix interference andto. sample diulion 04-Filters have Counts of trots; >60 or 80 and < 20: Estimated O t-Holding time exceeded prior to receipt at tab. 85-Too Many colonies were present too numerous to memt (iNTC) 02• Hafdlrg time exceeded lallaw ng receipt b7 tab 32- Reported value fa$ed to meet QC triteria for either precision or accuracy-.EstimatedPOL- Practical Qoan+.itatian Limit -subject to Chang a due to Instrument sensitivity ti- Samples analyzed for this compound but not detected J3-Ttre sample matrat interfered with the abillity to make arty accurate determination; Estimated .jti-The 1eb analyas was ham an unpreserved or improperly chemically prose vied sample: Estimated X7- Sample not ansiyzed far this campoiutd N1-The component has been tentatively identified based an mass spectraf liorary search and has an catenated value LAB Laboratory Section>> 1621 Mali Service CenW, Raleigh, NC 27699-1623 (919) 733,3908 Page 1 of 4 XC DWQ La6oratory Section Xesu(ts Sample ID AB44509 Locution 10: SATCOGEN003SW Collect Data: 05+20r2m Loc. Descr.' SAT COGEN O03 SW "ect Time;: 12i1S Vials 10 CAS 4 Analyse Name PQL Resutt Qualifier Units Ana'.ysVDote Approved By /Date Sampie tenVeneWre e% reoetpt by lab 1.9 'C HPARVZR SMATHIS w4MW Ratwence SC199 W!M9 WET ton ChromaWgraphy _TITLE_ -GA- AVVILLUWS CGREEN MtthcdRtferem EPA300.0 613m9 &12109 Total DISMOM3d Sdh:b In Ilquid 12 165 RKOL AQEXTER CGREEN ►legtod Re'arerxe Act-iA�:�•18;!- �:6G9 SR&'39 Ct1tt)ride 1 9.6 is MCA AWLLWAS CGREEN m4rbed Re`ertrxe EPA 3M.0 r5sw 601209 Fhxxi" 0.4 0.4 U-18 mglL AVALLLkM5 CGREEN McVrodRetertece EPA300.0 &VO w1z" SOI M 2 54 J8 MO& AVALLIAMS CGREEN L1sMod Relenmm EPA3MO f-S" &IZ.4i9 NUT NH3 as N In nqutd 0.02 Om ffTA as N MAJAYI CGREEN M44wd Refeterre Lac30•107-M-1-! S,2309 5nal% Total KjekWd N as N In UgL4d 0.2 OA7 fng& as N MOVF-RfAAN CGREEN Lteffwd Reference taCwI071162-+i 527,09 arm NO2*1403 az N in UqtW 0.02 0.05 ffG& as N MAJAYI CGREEN Ne9wd Reference keC14107-C4-:•c 5xzM)G W73R9 Putt. as P In Ugtffl 0.02 0.07 MWL as P 18ELA CGREEN fta9lodP.e'wwn Laclio0i&OIAEF SOWS &4..V9 MET 7A40-224 Ag by iClWS 5 5.0 V UWL .;JUAGEVICH ESTAFFORD 4 ogvd Referare EPA 2C0-8 SIA109 a717109 7429.90.5 Al 5y ICP SC 510 LwL SGDSS ESTAFFORD McOwd RefAfertce EPA 200 7 V27r09 9n2109 7440-38-2 As by'%CPMS 2 7.0 uglL - �-- - BSKiNNER ESTAFFORD McCiod References EPA 200.9 GMIN W12M 7429-W5 8 by ICP SG 65 UWL SGDSS ESTAFFORD Method ReTwvxm EPA 2CR7 stem 6n2M 74e0-36-3 an by tCP 10 21 �Ot SGDSS ESTAFFORD Mstllad Rc fw*i a EPA 2W.7 3rs" U12M 744041-7 So by iCP 5 &0 U Lot SGDSS ESTAFFORD motthad Rehuwxe EPA 2C0.7 507M ah=9 7440-70.2 Ca by iCP 0.1 38 IrOL SGDSS ESTAFFORD L1eibOd Refarwxe EPA 2C0.7 Sr28t09 W)00 Labomovy Sectlon» 1623 Mall Service Celstvr. Raltlgh. NC M99-1623 (919) T33-3M Page 2 of 4 N NC tD`U(lQ Laboratory Section 1Resufts sample ID A844508 lotion ID: BATCOGEN003SW Collect Date- OSM012009 7 Loc. Dew.: BAT COGEN 003 SW Collect Time:: 12:15 Vatt ID CAS # Analyze Name PIQL Result Qualifier Units AnalystlDate v Approved By /Date �— 7440-43-9 Cd by ICPMS 1 1.0 U u91L JJURGEVICH ESTAFFORD mete 7W Reference EPA200.8 6r24v09 W12Ki9 7440-484 CoW by lCP 50 50 U ugA- SGOSS ESTAFFORD MOT" Reference EPA 200,7 SW" W12i09 7440.47-3 Cr by ICPMS 10 10 U kt!YL JJI JRGEViCH ESTAFFORD 6leifta7 Re!eeance cPF. 2D08 W%109 6t12109 7440-50-8 CubyICPMS 2 20 U UWL JJURGEVICH ESTAFFORD Method RdtMMCe EPA 2.008 529.b9 6112A79 7439-09-6', - Feby}CP; 50 420 ugA. SGOSS ESTAFFORD Method Rele EPA 20Q7 5r27RPJ 8r12109 7439-97-6 He245.1 03 0.20 U aglL ESTAFFORD ESTAFFORD methw Reterenco EPA 24FK 1 6r11109 W12MS 74404)9-7 K by ICP 0.1 2.8 -WL SGOSS ESTAFFORQ Melltod Reference EPA 2D0.7 WSW 6n z= 7439-93-2 U tGP 25 25 U Vt SGOSS ESTAFFORD Metrwd Referenc4 EPA 200.7 5+-2-a05 W12ID9 7439-95-4 Me by ICP 0.1 1.7 MWI SGOSS ESTAFFORD r We9rodRdareisce EPA240.7 Sr2&04 aA2109 7439-9r-5 Wnby1CP 10 34 LOL SGOSS ESTAFFORD Mete Reterenca EPA 200.7 1a127r09 611M . 7439-93-7 MobyIC MS 40 10 U uglL JJURGEVICH ESTAFFORD kleu:od Rarer, -rue EPA M.8 5t291e9 611z" 7440-23-5 Na by IQP D.1 7-2 mg1L $GOSS ESTAFFORD Mdt1e4 Reference EPA 2110.7 5r2&O9 W12MG 7440-02-0 NI by.ICFMS 10 10 U tv& JJURGEVICH ESTAFFORD Method Reference EPA 20A 5.29A9 611?"9 7439 92-1 Pb by ICPMS 10 10 U ug/L JJURGEVICH ESTAFFORD Method Roterence EPA 200.E 5r19109 W12109 7440-36-0 SbbyICPMS 10 10 U UWL JJURGEVICH ESTAFFORD uvvr t Rerererca EPA 200.A sles,09 en 2109 7782-49-2 Se byICPMS 5 5.0 U ugh- JJURGEVICH ESTAFFORD irte hod Ralenence EPA 2.00.E &'29009 -&12109 7440-31-5 Sn by ICPM3 10 10 U UO& JJURGEVICH ESTAFFORD MsrA)d Reterenc6 EPA200.8. 529A9 4112.09 7440.28-0 Thallkirn M K3WS 10 10 U UIPL JJURGEVICH ESTAFFORD Method Reerenoe EPA 20R6 Stz91p9 W12109 Laboratory Sectiuv> 1623 Mail Service Center, Ralsigh, MC 27699 623 (919) 733-3M Page 3 of 4 WC (DWQ Laboratory Section (Resufts Sample ID ,gB44503 Location ID: SATCOGFN003SW Called Date: 05120l2009 Lnc. poser,: SAT COGEN 003 SW GoOect Time;: 12:15 Yisit ID CAS d An -ay a Kama POL kcyuYf Qualifier Umt5 AnafysLnaatr Approved fsy IDate 7440.32.6 _ TI fritpnhtm) by ICP TO 10 U UG& SGO SS ESTAFFORD m*Ood Reference EPA 200 7 W&C9 @ll21Ca 744C.62-2 V by ICP 25 25 U Ug& SGOSS ESTAFFORD Lsethed Reference EPA 200.7 577M9 W121n5 7440-F-" 7ntry 1CPMS' 10 21 vg/L JJURGEVICH ESTAFFORD MotiiodPeference EPA--aO.8 929+09 W12,119 �x Laboratory Seclloe» 1623 Mall Service Center, Raleigh, NC 27699.1623 1919) 733-3908 Page 4 of 4 i y�°� wnrEAoc PERMIT COVERAGE RENEWAL APPLICATION FORM Permit Number National Pollutant Discharge Elimination System NCS000350 Stormwater Discharge Permit THIS APPLICATION MUST BE SIGNED AND RETURNED ALONG WITH THE REQUESTED SUPPLEMENTAL INFORMATION TO THE DIV. OF WATER QUALITY IN ORDER FOR YOUR FACILITY TO QUALIFY FOR RENEWAL OF YOUR STORMWATER PERMIT NCS000350 The following is the information currently in our database for your facility. Please review this information carefully and make all corrections as necessary in the space provided to the right of the current information. OWNER INFORMATION Owner/Org. Name: EDGECOMBE GENCO LLC Owner Contact: Mailing Address: Phone Number: Fax Number E-mail address: Cdq,F_ Cq,%d.A 0mcric.a LLC ^ �� R. C�A�f� �• rr41M .0 C r P.O. .ary 1rJ 1 004o FACILITY INFORMATION Facility Name: EDGECOMBE GENCO, LI..C-BATrLEBORO Facility Contact: Facility Address: 6358 OLD 13A'iTLEBORO RD BATTLEBORO, NC 27809 Phone Number: Fax Number E-mail address: PERMIT INFORMATION Permit Contact: fi e Mailing Address: PO BOX 370 BATPLEBORO, NC 27809 Phone Number: 2524420805 Fax Number: E-mail address: DISCHARGE INFORMATION Discharge Receiving Water Stream Class: Basin: Sub -Basin #: Number of outfalls: CERTIFICATION _aez;j , _('_ t+15 w _ "1A i___AawAla-co - 1 certify that I am fa 'liar with the informat' n contained in the application and that to the best of my knowledge and belief such inform n is t ,complete a accurate. Signature Date O1.2xll_dl Print or type name of person signi g a ve Title �7 Please return this completed renewal application form to: Individual Permit Renewal Attn: Mr. Mike Randall Stormwater and General Permits Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 ` \ / � . ~ ^ ^ ^ ^ ' ^ m SUPPLEMENTAL INFORMATION REQUIRED FOR RENEWAL OF INDIVIDUAL NPDES STORMWATER PERMIT Two copies of each of the following shall accompany this submittal in order for the application to be considered complete: (Do not submit the site Stormwater Pollution Prevention Plan) Initials ulr� 1. A current Site Map from the Stormwater Pollution Prevention Plan. The location of industrial activities (including storage of materials, disposal areas, process areas and loading and unloading areas), drainage structures, drainage areas for each outfall, building locations and impervious surfaces should be clearly noted. A_ 2. A summary of Analytical Monitoring results during the term of the existing permit (if your permit required analytical sampling). Do not submit individual lab reports. The summary can consist of a table including such items as outfall number, parameters sampled, lab results, date sampled, and storm event data. * —Q�n� 3. A summary of the Visual Monitoring results. Do not submit individual monitoring reports. The summary can consist of a table including such items as outfall number, parameters surveyed, observations, and date monitoring conducted. 'k,A 4. A summary of the Best Management Practices utilized at the permitted facility. Summary should consist of a short narrative description of each BMP's in place at the facility. If the implementation of any BMP's is planned, please include information on these BMP's. —OW 5. A short narrative describing any significant changes in industrial activities at the permitted facility. Significant changes could include the addition or deletion of work processes, changes in material handling practices, changes in material storage practices, and/or changes in the raw materials used by the facility. 6. Certification of the development and implementation of a Stormwater Pollution Prevention Plan for the permitted facility (Sign and return attached form). * if the final year analytical monitoring of the existing permit term has not been completed prior to filing the renewal submittal, then the last years monitoring results should be submitted within 30 days of receipt of the laboratory reports. (i.e. do not withhold renewal submittal waiting on lab results) Representative storm sampling may now be conducted anytime during the year (the April to November window has been eliminated) and the representative rainfall event is now defined as a storm event that measures greater than 0.1 inches and is preceded by at least 72 hours in which no storm event measuring greater than 0.1 inches has occurred. L Drainage Ares t Drainage Area I sbm Drainage + ; Drainage Area I Dra nags Area 8 aA a o I `s Area 4 � 1 rtin� �r-• ���`, ,✓': i 1 , — O P o P 0I } a O CP / j A Drainage At" 9 f s !! - - - 1 i o o +[�• tdava m,hazle ratr, Drainage Area 3 •��� � � � I ��y--� I' a ��• r Eetcalalsweeltyerd� r^ ��r--' � T i I I ,aura I� Drainage Area 19 Drainage Area 1 ` F --- ¢ —O-� .�— L., I = =r=---►—=�f •, _' � a Area 6 De Area 7 ? ` \• rt' rf + I ii •.,nl�Jl� � Y 1 y T OudalOudal Nler Ne, 1 CCII &mmwaW �l Smm.re'.lr atne+nwn�' Ctttla't No. 2 f , I AOLdfA No. 3 OL9!O m_ t Legend Pawed Surface > Sbm watm Flow Diiradiwn Gravel Statece .......... Sit11n mmler Seller MO** — — Drainage Area: Boundary ° Dranage Crgch Bath StarrmNaler Dgd1 [ram StnrrnravaWr Outfall Drainage awale PalantlaiyExpased Msbrh& rnrs • Smmmimr Overland Flaw Area Drehrkg 10 Nbsborater Syshrm 5bmwdw Odld TOW Am 0-4 komb Wask Bads V-11 N*Aps Area VOTA ln"mmn Am VA* Famik h9mvkra P-= 01 Ma in Wk • wlKBeb CatkhftmAspe Aeaf No. t 14.76 2.40 12.35 4.55 V% I DAL OA3, OA4, O9 Ns.2 1.75 - 1.75 1.20 8% 0% am No.3 1.41 - 'Al OA2 3m 0% OA7 No.4 1.41 1.41 0.41 25% 0% OAio Ne.5 Im 1-C2 024 V% 0% 0" Owwwwp4w S." 575 1J4 32% 0% ml No Owd 2.70 2.70 - 100% OAS Figure 3. Edgecombe Gerterdting, LLC; Rocky Mount Plant Site Plan Showing Drainage Features and Areas Where Industrial Materials are Potentially Exposed to Stormwater rD &&*q swat rd alloto al quaraay w mu) O Ba1er au" FP64414 2 at 1,900 and 4 at 100 OS1292 1011. 150; v d 2 a1400 601Hum trydmxpa 100-,150 Q Twbkn 13tW rg UANkSUM 00CarfflnLKEMM� ks 2 al 2.0 a EJ-IC Cerdraesra Mydirvfle W 29180 o FOO lkjrstam Lute WA (aot61 a aq Hoa n Ash WA (soli M E dlimm 6laem WA WA o Aah Harding Ash WA (soUM a Condonaa4 Tent WA WA r Tmn$f mW Yardl Tramiku rrar o4 2 a19,170 ud 2 a1 It90 Of Trap P% Wee. of prow 13,126 K Admhdafra0an Oala WA WA L DatnttenlmK t31>fhuk add rid 4Z _ _ 250; and 4 Z r Dsmkf aump f arkra Tank Me. waalewster 50O r Tsdc Wagewder 3e,P00 125 Oa 'hornka4 mism 400 ery WA WA RawvvmwTar" WA WA IF.P.Tramforrr>rrTranstmerof Otrmpatm I Urdv. Waite WA WA C00%V Ttlwwo Go*" lower draminla WA wasmwaltr Baskm WA WA wnlslvSW Brrtklwtg BN� 2 a ac 6655 worehouse! 6hop MLU. hduaM products Mtdlpls, a0 a65 a Trawar WA WA T Dr mr 9foraga Ama Used o5 6m Y ON Stange ell" Mlae, of ptoduds Mttflple, ai -65 Cmdaromm Ream WA WA Coal Unbodtrg Cmaakumni No. 1 Tank 1 A Ok" N wla Trmw a$ � Unloedrq Bey WA WA spamr Area Hydrarrwc ON 30 Locomotive Parift ARsc. oe products .66 ICar CaU 1iL kota Conwittr Coal WA Coat Pia Cal WA Cool Campr Cal WA N Laydown Nee WA WA 4 Wscete{twq Drainage Area 1 Drainage Area 4 R y a ■ R � I ' ' N r e II Drainage Area 3 (v I, r Drainage Area t Sto arar Met Ma.1 Legend I� FIRM swbm > Sbmrwa6u Fbw Dhcdm Gra"I Swbm ....•..... Stomm515r Sneer (6urlWO — Dt4ri W All, Boundary Y Dreinape Catch Bnlln ......-- SWrrwAsw Di(Oh StWnrrffier DIAhd = == DrairM Swab Po(en11* Exposed tl labbw Stour nbi Weft d Pm Area Dr5"b Weab*&Ir 9r t II O a 6 Fe NVIN Drainage Area 1 n Drainage Area 4 �! �~ Drainage Area B i it • AF -L-7 Drainage Area g (diim Io Wmvwabr&LIiN UCI Drairaga Area 10 Dra rage Area 6 �� \ L? Drainage Area 7 it\• I ////// �4 i �I ..•nnrt, y H E 5brruaabr Odd low Ma 01:01114 Mato ftdo Bath V-d b map Am Va" mp r mre Ma VA* pmma -- mrpavla. pmaadd AmInWadw "brBmir CmffbramgC 1 0 Arne W.1 14.76 240 1235 4m 37% In DA$ DA3, DM, DA5 No.2 675 - 135 1.20 0% 0% oAA ft3 IAI - I.41 9.42 m% 0% DA7 W.4 IM - IA1 0.47 20% 0% DAM No.5 142 - 1.02 024 23% 0% DAD OmIWFba 5.7a D.7e IA4 32% 0% DA1 '.No00d 270 270 ION DAD Figure 3. Edgecombe Generating, LLC; Rocky Mount Plant Site Plan Showing Drainage Features and Areas Where industrial Materials are Potengaily Exposed to Stormwater N BuAdrrp A4rdvfd 41u�igty (alon) Qadwaulft MP54414 28t1900Wd4at100 400 t00; 160; �tOOW; Ba tW a ISO Q Turt4nts Buedlrng LuWcAlon s6 of Cor*rmnzMn tAAn e eHC Carmolara al 20180 o FBD Bytom Lk" WA (to" a Bag Nmmes Ash WA (a" F� h&M RUM WA WA o Ash hrarding Ash WA (@din K CarndermtaTank WA WA r Tmnskmmr Yards Ttarmbmer or 21 l %170 Wd 2 ar M 01 Trap Pa NUr. al poduele 13.126 R Adminftbillm OfAca WA WA L DemirmtMor BuNing suftle 130 md,,5ag la�epk�a�a 280 ad 4 DisaN Kral 0 Damto sump 19** Tart Mhc raslewWer sm R NeumdzdmnTonk Westardtt 35,W0 o EFP.Trankmnr Tnrnbmlarol 126 P Damin Ctmriksts Bo1500 4m a UNCIR g Bay WA WA R Rm WWer Tints WA WA a Drmtprisn I Uniu, Was1a NA WA T Co" TOW= Coorkq tower OmffkA rs WA u wadsweler auks VA WA v Vftovm tar Buldhq 2 a 6d Br�tamAft Wsraffirrsa l shop WK. kdoatlar wndmis ULd", ao go t Trder WA WA r onsn emraga Am Lhod of am = 01 st mp Buntlmg her- of Prodrreta mlej a, ag eg5 Cwd a= Ram, WA WA Coe! ureeadirra CW" mynr TWAI I D�1 No. A Kercum To* ON UnbeArg64ry2 WA WA CWapw6srAraa Nydrsrmeal 30 LocomOm Poking Nbr. D! produeS1 6D Corr sbdod Conwym Cal WA Coe[ Pik+ Cal WA Ow CmmrmYCr Coo WA a Ltyd7Rn Mee WA WA o mSmile ON[) Item 3. Summary of Visual Examination of Stormwater Runoff Data Edgecombe Generating, LLC; NPDES Stormwater Permit No. NCS000350 Parameter OutfallI Outfall2 Outfall3 Outfall4 Outfall5 Color and Extent Absent Absent Absent Absent Absent Odor Absent Absent Present Present Absent Clarity or Turbidity Absent Absent Absent Present Present Floating Solids Absent Absent Absent Absent Absent Settled Solids Absent Absent Absent Absent Present Foam Absent Absent Absent Absent Absent Oil Sheen Absent Absent Absent Absent Absent Other Obvious Indicators of Absent Absent Absent Absent Absent Stormwater Pollution Notes: 1. See EHS Form 055 for description of the parameters. 2. The "Present" odor at Outfalls 3 and 4 was observed to be "musky"; neither Outfall drains an industrial area of the plant. 3. The "Present" turbidity at Outfalls 4 and 5 is likely due to influences from farm field immediately east of the Plant. Item 3. Summary of Visual Examination of Stormwater Runoff Data Edgecombe Generating, LI.C; NPDES Stormwater Permit No. NCS000350 Parameter Outfall1 Outfall2 Outfall3 Out#a114 Outfall5 Color and Extent Absent Absent Absent Absent Absent Odor Absent Absent Present Present Absent Clarity or Turbidity Absent Absent Absent Present Present Floating Solids Absent Absent Absent Absent Absent Settled Solids Absent Absent Absent Absent Present Foam Absent Absent Absent Absent Absent Oil Sheen Absent Absent Absent Absent Absent Other Obvious Indicators of Absent Absent Absent Absent Absent Stormwater Pollution Notes, I. See EHS Form 055 for description of the parameters. 2. The "Present" odor at Outfalls 3 and 4 was observed to be "musky"; neither Outfall drains an industrial area of the plant. 3. The "Present" turbidity at Outfalls 4 and 5 is likely due to influences from farm field immediately east of the Plant. Edgecombe Generating, LLC - Location of Stormwater Outfalls Stormwater Ouffall No. 5 00r.5 00 Storrrtwater Stormwater Stomnwater Stormwater Outfall No. 1 Outfall No, Z Outfall No, 3 Outfall No. 4 WORKSHEET A7 VISUAL ExArmNAT1oN OF STORMWATER QuAL[TY ' FORM EMS 055 10 (' aentiiX NPDES GENERAL PERMIT FOR STORMWATER DISCHARGES OCTOBER 2004 ASSOCIATED WITH INDUSTRIAL ACTMTY STORM.EVENT INFORMA,TION , ,., Duration: hours minutes Outfall No. Date: Precipitation: inches Time: RunofF gallons Examiner: Preying Event: �_ days �_ hours Rain: Snow: •ACCEFFABLE CONDITIONS FOR CONI)UCTIiVG EXAM1NATiON Meets Re uirement Requirement for Acceptable Examination Yes No I. Observations began =I -hour of start of discharge: 2. Storm Event >O.I-inches of precipitation: 3. Storm Event occurs >72-hours of previous storm event with >0. I -inches of i nation. EXAMINATION RESU1 Ili Observations Parameter Method Absent Present Describe if Present Observe sample through a clean 1.0-L, glass beaker against a Color and Extent white background. If sample is the same as white background. mark 'Absent" otherwise mark "Present'. Note the color and intensity (e.g., gray. light or brown, dark). Smell the sample and mark `Absent" or 'Present' and if Odor "Present', note type (e.g.. earthy, sewage, musky, oily, etc.) and strength (eg.. weak, moderate, or strong). Observe sample through a clean 1.0-L, glass beaker against a white background. If sample is the same as the white Clarity or Tumidity background. mark `Absent" otherwise mark "Present". If 'Present', note (1) cannot see background, (2) can see that beaker but cannot read newsprint, (3) can see thru beaker and read newsprint, or (4) the water is faintly turbid. Floating Solids Observe if "Absent" or 'Present" and describe the sollds. Settled Solids Observe if any material settles to the bottom of the 1.0-L beaker after 5-minutes. Suspended Solids Observe If 'Absent' or 'Present' based on the results of the Clarity and Settle Solids tests and describe the solids. Foam Observe if "Absent" or "Present". If "Present" note thickness. coverage of channel, and color. Oil Sheen Observe if "Absent" or 'Present'. If 'Present' note coverage of channel and color. Other Obvious Indicators Describe what was ' observed that would lead a reasonable of Storm Water Pollution person to believe that the stormwater was polluted. CERTIFICATION I certify under penalty of Iaw that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. Name and Title Print Si tore Date WORKSHEET A7 r=_117 08.1m VISUAL EXAMINATION OF STORMWATER QUALITY FORM EHS 055 NPDES GENERAL PERMIT FOR STORMWATER DISCHARGES OCTOBER 2004 ASSOCIATED WITH INDUSTRIAL ACTIVITY STORM[ EVENT' ON " Duration: hours minutes Outfall No. Date: Precipitation: inches Time: .Runoff- gallons Examiner. Preceding Event: days ❑ hours Rain: Snow: ACCEPTABLE CONbITIONS,FOR CONDUCTING EXAIYIINATIO N Meets R uirement Requirement for Acceptable Examination Yes No 1. Observations =1-hour of start of discharge: 2. Storm Event >0.1-inches of precipitation: 3. Storm Event occurs >72-hours of previous storm event with >0.1-inches of precipitafion. EXAMINATION RESULTS :: Observations Parameter Method Absent Present Describe if Present Observe sample through a clean 1.0-L, glass beaker against a Color and Extent white background. If sample is the same as white background. 'Present'. mark "Absent" otherwise mark Note the color and Intensity (e.g., gray, light or brawn, dark). Smell the sample and mark 'Absent" or 'Present' and if Odor 'Present', note type (e.g., earthy, sewage, musky, oily, etc.) and strength (e g.. weak, moderate, or strong). Observe sample through a clean 1.0-L, glass !esker against a white background. If sample is the same as the white Clarity or Turbidity background, mark "Absent' otherwise mark "Present-. If *Present'. note (1) cannot see background, (2) can see thru beaker but cannot read newsprint, (3) can see thru beaker and read newsprint, or (4) the water is faintly turbid. Floating Solids Observe if "Absent' or "Present' and describe the solids. Settled Solids Observe If any material settles to the bottom of the I.0-L beaker after 5-minutes. Suspended Solids Observe if 'Absent' or "Present" based on the results of the Clarity and Settle Solids tests and describe the solids. Foam Observe if 'Absent" or "Present'. If "Present" note thickness, coverage of channel. and color. 011 Sheen Observe if "Absent" or "Present". If 'Present" note coverage of channel and color. Other Obvious Indicators Describe what was observed that would Iead a reasonable of Storm Water Pollution person to believe that the stormwater was polluted. CERTIhICATION . I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. Name and Title not Signature Date WORKSHEETA5 Facility: Edgecombe Genclatirq , LLC EXISTING/TRADITIONAL STORMWATER MANAGEMENT Rev.. I PRACTICES WORKSHEET Date. October 23, 2006 Page: 1 BEST MANAGEMENT PRACTICE COMMENTS Maintenance of Secondary Containment Areas — See Table A5.1 for secondary containment area details. All secondary containment areas will be routinely observed to determine fitness for service; any deficiencies will be reported to the Plant management. Preventative Maintenance and Good Housekeeping Program —The Rocky Mount Plant regularly maintains and keeps in a clean, orderly manner, areas which may contribute pollutants to storm water discharges. Good housekeeping procedures implemented at the facility include the following: 1. Perform general weekly inspections of facility and equipment areas to maintain a safe and trash free environment. Street sweeping is performed as needed. 2. Routinely inspect exposed plant equipment for leaks or conditions that could lead to discharges of chemicals or petroleum products. Records of inspections are kept in the fax room on the first floor of the administration building. 3. Proper inventory control procedures to insure that stored chemicals and petroleum products are maintained at the minimum level necessary. 4. Proper material storage practices to ensure that materials are stored in containers adequate for the locations, such that corrosion and deterioration of the containers is minimized. This includes proper labeling of all containers and maintenance of MSDS on materials stored. The preventive maintenance program for the facility includes inspecting and maintaining the storm water management devices, equipment, and systems, on a semi-annual basis, to prevent the discharge of pollutants to surface waters. In addition, the storm water management devices, equipment, and systems are visually inspected on a daily basis. Bulk storage tanks, transformers, and heavy equipment are inspected on a quarterly basis, and visually inspected on a daily basis. Records of quarterly/semi-annual inspections are kept in the Administration Building. Employee Training — The Plant conducts annual training programs for personnel responsible for any aspect of storm water management, including those individuals responsible for implementing activities identified in the Plan. This training will inform responsible personnel of the components and goals of the Plan and will address topics related to storm water management, such as: 1. Good housekeeping; 2. Spill prevention and response; and 3. Material handling and storage practices. In addition, each member of the Plant's Pollution Prevention Team will undergo initial training on the Plan prior to implementation. If a member joins the Team after the Plan has been implemented, they will be trained prior to becoming listed in the Plan as a Team member. Where possible, employee training under the Plan can be conducted in conjunction with training under other regulatory programs (e.g., hazardous waste management training, SPCC training). Currently Plan training is conducted at least annually through the safety meeting program. Employees attending Plan training will sign the attendance roster. Names of those in attendance are recorded in a plant -wide training matrix. A manager and/or section leader will follow up with employees who were not in attendance at the Plan training. Records of the training programs will be maintained on file in the Administration Building. Responsible Party — The Plant Manager is the responsible party for the Rocky Mount Plant. See Section 2.2 above, for the Plant Manager's signed certification of this Stormwater Pollution Prevention and Stormwater Management Plan WORKSHEETA5 Facility: Edgecombe Generating, LLC EXISTING/TRADITIONAL STORMWATER MANAGEMENT Rev.: 1 PRACTICES WORKSHEET Date: October 23, 2006 Page: 2 BEST MANAGEMENT PRACTICE COMMENTS Plan Amendment — The Rocky Mount Plant will amend/revise the Plan whenever there is a change in design, construction, operation, or maintenance which has a significant effect on the potential for the discharge of pollutants to surface waters. The Stormwater Pollution Prevention Plan will be reviewed and updated on an annual basis. Facility Inspection Program — One of the core stormwater requirements is to conduct Facility Inspections on at least an annual basis — Worksheet A2 can be used for this purpose. Members of the Pollution Prevention Team will conduct the evaluation annually. This evaluation provides a basis for evaluating the overall effectiveness of the SWPP Plan. The compliance evaluation includes the following elements: I . A visual INSPECTION of the site 2. Based on the results of the INSPECTION, revisions to the SWPP Plan and implementation of any additional measures and controls 3. A written report summarizing the results of the annual evaluation (Worksheet AG may be used for this purpose) Implementation of changes — Based on the results of the annual INSPECTION, necessary revisions to pollution prevention measures, controls, and the SWPP Plan should be initiated within 2 weeks of such INSPECTION. Revisions should be completed within 12 weeks of the INSPECTION. • The SWPP Plan shall be reviewed and the following sections updated, where necessary: • Changes to the Pollution Prevention Team member roster (Worksheet Cl) • The inventory of SIGNIFICANT MATERIALS and BMPs (Worksheet Al, Site Drainage Map) • The history of significant SPILLS and leaks (Worksheet BI) A report summarizing the CSC Evaluation will be prepared and maintained in accordance with Worksheet A( in the Plan. Among other things, this Report will summarize major observations relating to the implementation of the Plan, describe necessary or appropriate revisions to the Plan, and identify incidents of noncompliance with the Plan. If no incidents of noncompliance are identified in the Report, the Rocky Mount Plant will certify that the facility is in compliance with this PLAN, The CSC Evaluation Report, and any necessary certification, will be maintained on file in the Administration Building, WORKSHEETA5 Facility: Edgeeombe Generating, LLC EXISTING/TRADITIONAL STORMWATER MANAGEMENT Rev.: I PRACTICES WORKSHEET Date: October 23, 2006 Page: 3 I BEST MANAGEMENT PRACTICE I COMMENTS 1 Pollution Prevention Team — Worksheet Cl in Appendix C identifies individuals within the facility organization who have been designated as members of the facility Pollution Prevention Team. Team members are responsible for implementing and maintaining this Plan. The number of members on the team will vary depending on the size of the facility. As a standardized approach, the FACILITY MANAGER and the Compliance Supervisor assigned to the facility ("Facility Compliance Supervisor") are core members of the team and are listed in Worksheet C 1. FACILITY MANAGERS are encouraged to assign additional site members to the team as part of their employee involvement initiatives. Additional Pollution Prevention Team members and their responsibilities should be listed in Worksheet Cl. The FACILITY MANAGER is ultimately responsible for the implementation of this Plan. The FACILITY MANAGER is accountable for the prevention of SPILLS and leaks that could adversely impact surface water or ground water. The FACILITY MANAGER is responsible for ensuring that: 1. The Plan is implemented, maintained, and amended at the intervals required in the Plan; 2. Appropriate measures and controls (BMP's) are implemented and maintained; 3. Periodic INSPECTIONS are conducted; 4. Corrective or follow-up actions are completed in a timely manner; S. All SPILLS are promptly reported and cleaned up; and 6. Employees are periodically trained on Pollution Prevention. WORKSHEETAS Facility: EdgecombeGenerating, LLC EXISTINGfF ADITIONAL STORMWATER MANAGEMENT Rev.: I PRACTICES WORKSHEET Date: October 23, 2006 Page: I BEST MANAGEMENT PRACTICE - COMMENTS Maintenance of Secondary Containment Areas — See Table AS.I for secondary containment area details. Ali secondary containment areas will be routinely observed to determine fitness for service; any deficiencies will be reported to the Plant management. Preventative Maintenance and Good Housekeeping Program — The Rocky Mount Plant regularly maintains and keeps in a clean, orderly manner, areas which may contribute pollutants to storm water discharges. Good housekeeping procedures implemented at the facility include the following: I . Perform general weekly inspections of facility and equipment areas to maintain a safe and trash free environment. Street sweeping is performed as needed. 2. Routinely inspect exposed plant equipment for leaks or conditions that could lead to discharges of chemicals or petroleum products. Records of inspections are kept in the fax room on the first floor of the administration building. 3. Proper inventory control procedures to insure that stored chemicals and petroleum products are maintained at the minimum level necessary. 4. Proper material storage practices to ensure that materials are stored in containers adequate for the locations, such that corrosion and deterioration of the containers is minimized. This includes proper labeling of all containers and maintenance of MSDS on materials stored. The preventive maintenance program for the facility includes inspecting and maintaining the storm water management devices, equipment, and systems, on a semi-annual basis, to prevent the discharge of pollutants to surface waters. In addition, the storm water management devices, equipment, and systems are visually inspected on a daily basis. Bulk storage tanks, transformers, and heavy equipment are inspected on a quarterly basis, and visually inspected on a daily basis. Records of quarterly/semi-annual inspections are kept in the Administration Building. Employee Training — The Plant conducts annual training programs for personnel responsible for any aspect of storm water management, including those individuals responsible for implementing activities identified in the Plan. This training will inform responsible personnel of the components and goals of the Plan and will address topics related to storm water management, such as: 1. Good housekeeping; 2. Spill prevention and response; and 3. Material handling and storage practices. In addition, each member of the Plant's Pollution Prevention Team will undergo initial training on the Plan prior to implementation. If a member joins the Team after the Plan has been implemented, they will be trained prior to becoming listed in the Plan as a Team member. Where possible, employee training under the Plan can be conducted in conjunction with training under other regulatory programs (e.g., hazardous waste management training, SPCC training). Currently Plan training is conducted at least annually through the safety meeting program. Employees attending Plan training will sign the attendance roster. Names of those in attendance are recorded in a plant -wide training matrix. A manager and/or section leader will follow up with employees who were not in attendance at the Plan training. Records of the training programs will be maintained on file in the Administration Building. Responsible Party — The Plant Manager is the responsible party for the Rocky Mount Plant. See Section 2.2 above, for the Plant Manager's signed certification of this Stormwater Pollution Prevention and Stormwater Management Plan WORKSHEETAS Facility: Edgecombe Generating, LLC EXISTING/TRADITIONAL STORMWATER MANAGEMENT Rev.: I PRACTICES WORKSHEET Date: October 23, 2006 Page: 2 BEST MANAGEMENT PRACTICE COMMENTS Plan Amendment — The Rocky Mount Plant will amend/revise the Plan whenever there is a change in design, construction, operation, or maintenance which has a significant effect on the potential for the discharge of pollutants to surface waters. The Stormwater Pollution Prevention Plan will be reviewed and updated on an annual basis. Facility Inspection Program — One of the core stormwater requirements is to conduct Facility Inspections on at least an annual basis — Worksheet A2 can be used for this purpose. Members of the Pollution Prevention Team will conduct the evaluation annually. This evaluation provides a basis for evaluating the overall effectiveness of the SWPP Plan. The compliance evaluation includes the following elements: . A visual INSPECTION of the site 2. Based on the results of the INSPECTION, revisions to the SWPP Plan and implementation of any additional measures and controls 3. A written report summarizing the results of the annual evaluation (Worksheet A6 may be used for this purpose) Implementation of changes — Based on the results of the annual INSPECTION, necessary revisions to pollution prevention measures, controls, and the SWPP Plan should be initiated within 2 weeks of such INSPECTION. Revisions should be completed within 12 weeks of the INSPECTION. • The SWPP Plan shall be reviewed and the following sections updated, where necessary: • Changes to the Pollution Prevention Team member roster (Worksheet Cl) • The inventory of SIGNIFICANT MATERIALS and BMPs (Worksheet Al, Site Drainage Map) • The history of significant SPILLS and leaks (Worksheet B 1) A report summarizing the CSC Evaluation will be prepared and maintained in accordance with Worksheet A6 in the Plan. Among other things, this Report will summarize major observations relating to the implementation of the Plan, describe necessary or appropriate revisions to the Plan, and identify incidents of noncompliance with the Plan. if no incidents of noncompliance are identified in the Report, the Rocky Mount Plant will certify that the facility is in compliance with this PLAN. The CSC Evaluation Report, and any necessary certification, will be maintained on file in the Administration Building. WORKSHEETA5 Facility: EdgecombeGencmting,LLC EXISTING/TRADITIONAL STORMWATER MANAGEMENT Rev.: 1 PRACTICES WORKSHEET Date: October 23, 2006 Page: 3 BEST MANAGEMENT PRACTICE I COMMENTS I Pollution Prevention Team -- Workshect Cl in Appendix C identifies individuals within the facility organization who have been designated as members of the facility Pollution Prevention Team. Team members are responsible for implementing and maintaining this Plan. The number of members on the team will vary depending on the size of the facility. As a standardized approach, the FACILITY MANAGER and the Compliance Supervisor assigned to the facility ("Facility Compliance Supervisor") are core members of the team and are listed in Worksheet Cl. FACILITY MANAGERS are encouraged to assign additional site members to the team as part of their employee involvement initiatives. Additional Pollution Prevention Team members and their responsibilities should be listed in Worksheet C1. The FACILITY MANAGER is ultimately responsible for the implementation of this Plan. The FACILITY MANAGER is accountable for the prevention of SPILLS and leaks that could adversely impact surface water or ground water. The FACILITY MANAGER is responsible for ensuring that: 1. The Plan is implemented, maintained, and amended at the intervals required in the Plan; 2. Appropriate measures and controls (BMP's) are implemented and maintained; 3. Periodic 1NsPeCTIONs are conducted; 4. Corrective or follow-up actions are completed in a timely manner; 5. All SPILLS are promptly reported and cleaned up; and 6. Employees are periodically trained on Pollution Prevention. Worksheet A5.1 Summary of Secondary Containment at the Edgecombe Generating, LLC; Rocky Mount Plant Largest Containment Map Plan Section /Location Description Significant Material Capacity Single Rainfall Runoff Volume ID (gallons) Capacity (gallons) Direction (gallons) (gallons) 6.2.1 / Boiler Building A Various boiler chemicals Unit I Bulk Tank for HP54414 1,000 Unit 2 Bulk Tank for HP54414 1,000 Unit 1 Day Tank for HP54414 100 Unit 2 Day Tank for HP54414 100 Unit 1 OS 1292 Tote 400 1,000 NIA' 2,1002,1 NIA' Unit 2 OS 1292 Tote 400 Unit 1 OS 1292 Day Tank 100 Unit 2 OS 1292 Day Tank 150 Unit I Sodium hydroxide tank 100 Unit 2 Sodium hydroxide tank 150 6.2.2 / Turbine Building B Turbine lube oil sumps Lubricating oil 2,000 N/Al See Note 4 NIA' C EHC units Hydraulic oil 80 N/A1 270 NIA' 6.2.3 / Transformer Yards I Transformers Transformer of 1 9,170 N/A5 See Note 4 to Oil Trap Pit 6.2.4 / Oil Trap Pit I Oil trap pit Misc. oil products 9,170 1,420 13,125 Industrial6 6.2.5 / Demineralizer L Bulk acid tank Sulfuric acid 4,500 6,730 NIA' 6,730 NIA' Building and Adjacent Bulk caustic tank Sodium hydroxide 4,500 6,950 N/A1 6,950 NIA' Areas Acid day tank Sulfuric acid 130 340 NIA 340 I N/A Caustic day tank Sodium hydroxide 280 Tank for diesel fire pump Diesel fuel 300 650 NIA' 650 N/A� O EFP Transformer Transformer oil 125 650 N/A5 650 Industrial6 P Outdoor chemical storage Continuum AEC3153 1,625 OX1202 (sodium bromide) 400 1,910 N/A6 1,910 Industria16 BD 1500 400 Page 1 of 2 Print Date: 19.Oct.2006 Worksheet A5.1 Summary of Secondary Containment at the Edgecombe Generating, LLC; Rocky Mount Plant Largest Containment Map Capacity Single Rainfall Runoff Plan Section /Location ID Description Significant Material (gallons) Capacity (gallons) Volume Direction (gallons) (gallons) 6.2.6 / Wastewater V Acid drums (2) Sulfuric acid 55 55 N/Al 55 N/Al Building Caustic drums (2) Sodium hydroxide 55 55 N/A1 55 NIA` 6.2.7 / Drum Storage Y Used oil tank Used oil 500 500 N/A7 2,270 Stormwater7 6.2.8 / Oil Storage Multiple oil products with a Z Builidng Multiple oil products combined volume of ±1,1GO-gal 55 55 N/A1 350 N/Al 6.2.9 / Rail Car Unloading Bb Diesel Tank No. 1 Diesel fuel 11000 Area Diesel Tank No. 1 Diesel fuel 250 Kerosene tank Kerosene 300 1,000 2,B 10 14,380 Stormwater Spare transformer Transformer oil 99 Dd Car spotter unit 8 Hydraulic oil 30 30 130 2802'8 Stormwater 6.2.10 / Locomotive Ee Locomotive parking area Miscellaneous oil products 210 210 120 440 Stormwater Parking Area Notes: l . No accumulated water because tanks/equipment are located indoors. 2. Exempt from SPCC per 40 CFR 112.1(d)(5). 3. Exempt from Stormwater Permit No. NCS000350 because area is located indoors. 4. Meets 40 CFR 112.7(c) by diversion to the Oil Trap Pit. 5. Oil is in Operating Equipment, no provision for accumulated water required per 40 CFR l I2.7(c). 6. Drains into the Wastewater Basin and discharged per NPDES Permit NC0077437, Outfall 003. 7. No accumulated water because tanks/equipment are fully under a roof. 8. Exempt from Stormwater Permit No. NCS000350 because Significant Material is in operating equipment. Page 2 of 2 Print Date: 19.Oct.2006 Worksheet A5.1 Summary of Secondary Containment at the Edgecombe Generating, LLC; Rocky Mount Plant Largest Containment Map Capacity Single Rainfall Runoff Plan Section 1 Location ID Description Significant Material (gallons) Capacity (gallons) Volume Direction (gallons) (gallons) 6.2.1 / Boiler Building A Various boiler chemicals Unit I Bulk Tank for HP54414 1,000 Unit 2 Bulk Tank for HP54414 1,000 Unit 1 Day Tank for HP54414 100 Unit 2 Day Tank for HP54414 100 Unit 1 OS 1292 Tote 400 1,000 NIA' 2, 1002,1 NIA' Unit 2 OS 1292 Tote 400 Unit I OS 1292 Day Tank 100 Unit 2 OS 1292 Day Tank 150 Unit 1 Sodium hydroxide tank 100 Unit 2 Sodium hydroxide tank 150 6.2.2 / Turbine Building B Turbine lobe oil sumps Lubricating oil 2,000 N/A' See Note 4 NIA' C EHC units - Hydraulic oil 80 N/A' 270 N/A' 6.2.3 / Transformer Yards I Transformers Transformer oil 9,170 N/A5 See Note 4 to Oil Trap Pit 6.2.4 / Oil Trap Pit J Oil trap pit Misc. oil products 9,170 1,420 13,125 Industrial6 6.2.5 / Demineralizer L Bulk acid tank Sulfuric acid 4,500 6,730 N/A' 6,730 NIA' Building and Adjacent Bulk caustic tank Sodium hydroxide 4,500 6,950 N/A' 6,950 N/A' Areas Acid day tank Sulfuric acid 130 340 N/A' 340 N/A' Caustic day tank Sodium hydroxide 280 Tank for diesel fire pump Diesel fuel 300 650 NIA' 650 N/A' O EFP Transformer Transformer oil 125 650 N/A' 650 Industrial6 P Outdoor chemical storage Continuum AEC3153 1,625 OX1202 (sodium bromide) 400 1,910 N/A6 1,910 Industrial6 BD 1500 400 Page 1 of 2 Print Date: 19.Oct 2006 Worksheet A5.1 Summary of Secondary Containment at the Edgecombe Generating, LLC; Rocky Mount Plant Largest Containment Plan Section 1 Location Map Capacity Single Rainfall Description Significant Material Volume Runoff ID (gallons) Capacity (gallons) (gallons) Direction (gallons) 6.2.6 / Wastewater V Acid drums (2) Sulfuric acid 55 55 N/Al 55 N/A' Building Caustic drums (2) Sodium hydroxide 55 55 N/Al 55 N/A' 6.2.7 / Drum Storage Y Used oil tank Used oil 500 500 N/A' 2,270 Stormwater' 6.2.8 / Oil Storage Z Multiple oil products with a Multiple oil products 55 55 N/A 350 NIA i Builidng combined volume off1,100-gal 6.2.9 / Rail Car Unloading Bb Diesel Tank No. 1 Diesel fuel 1,000 Area Diesel Tank No. 1 Diesel fuel 250 1,000 2,810 14,380 Stormwater Kerosene tank Kerosene 300 Spare transformer Transformer oil 99 Dd Car spotter uniY'e Hydraulic oil 30 30 130 2802"' Stormwater 6.2.10 / Locomotive Ee Locomotive parking area Miscellaneous oil products 210 210 120 440 Stormwater Parking Area Notes: 1. No accumulated water because tanks/equipment are located indoors. 2. Exempt from SPCC per 40 CFR 1 ] 2.1(d)(5). 3. Exempt from Stormwater Permit No. NCS000350 because area is located indoors. 4. Meets 40 CFR I I2.7(c) by diversion to the Oil Trap Pit. 5. Oil is in Operating Equipment, no provision for accumulated water required per 40 CFR I I2.7(c). 6. Drains into the Wastewater Basin and discharged per NPDES Permit NC0077437, Outfall 003. 7. No accumulated water because tanks/equipment are fully under a roof. S. Exempt from Stormwater Permit No. NCS000350 because Significant Material is in operating equipment. Page 2 of 2 Print Date: 19.Oct.2006 STORMWATER POLLUTION PREVENTION PLAN DEVELOPMENT AND IMPLEMENTATION CERTIFICATION N.C. Division of Water Quality, Stormwater and General Permits Unit Facility Name: EDGECOMBE GENCO, LLC-BATTLEBORO Permit Number: NCS000350 Location Address: 6358 OLD BATTLEBORO RD BATTLEBORO, NC 27809 County: EDGECOMBE "I certify, under penalty of law, that the Stormwater Pollution Prevention Plan (SPPP) document and all attachments were developed and implemented under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information required by the SPPP. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information gathered is, to the best of my knowledge and belief, true, accurate, and complete" "I certify that the SPPP has been developed, signed and retained at the facility location and the SPPP has been fully implemented at the named facility location in accordance with the terms and conditions of the stormwater general permit." "I am aware that there are significant penalties for falsifying information, including the possibility of fines and imprisonment for knowing violations" Sign (according to permit signatory requirements) and return this Certification. DO NOT SEND THE STORMWATER POLLUTION PREVENTION PLAN WITH THE CERTIFICATION. Signature Date _ / ,x Y/d L R�►rd• i'i�'1�4Sr r Print or type name of person signing above Title SPPP Certification 2/99 STORMWATER POLLUTION PREVENTION PLAN DEVELOPMENT AND IMPLEMENTATION CERTIFICATION N.C. Division of Water Quality, Stormwater and General Permits Unit Facility Name: EDGECOMBE GENCO, LLC-BATTLEBORO Permit Number: NCS000350 Location Address: 6358 OLD BATTLEBORO RD BATTLEBORO, NC 27809 County: EDGECOMBE "I certify, under penalty of law, that the Stormwater Pollution Prevention Plan (SPPP) document and all attachments were developed and implemented under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information required by the SPPP. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information gathered is, to the best of my knowledge and belief, true, accurate, and complete" "I certify that the SPPP has been developed, signed and retained at the facility location and the SPPP has been fully implemented at the named facility location in accordance with the terms and conditions of the stormwater general permit." "I am aware that there are significant penalties for falsifying information, including the possibility of fines and imprisonment for knowing violations" Sign (according to permit signatory requirements) and return this Certification. DO NOT SEND THE STORMWATER POLLUTION PREVENTION PLAN WITH THE CERTIFICATION. Signature Date 4 J�Y �Q 4-. Acd S• F-s—wc� r +MA,49A E r Print or type name of person signing above Title SPPP Certification 2/99 March 17, 2006 Mr. Richard S. Frymyer Edgecombe Genco, LLC 6358 Old Battleboro Road Battleboro, NC 27809 Dear Mr. Frymyer: Michael F, Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality Subject: Permit No. NCS000350 Edgecombe Genco, LLC Formerly Cogentrix of Rocky Mount, LLC Edgecombe County Division personnel have reviewed and approved your request to transfer coverage under the Individual Permit Number NCS000350, received on February 9, 2006. Please find enclosed the revised permit cover sheet. The terms and conditions contained in the remainder of the permit remain unchanged and in full effect. This revised permit is issued under the requirements of North Carolina General Statutes 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency. If you have any questions, please contact the Stormwater Permitting Unit at (919) 733-5083, extension 502. Sincerely, Alan W. Klimek P. E. cc: DWQ Central Files Raleigh Regional Office, Water Quality Section Stormwater Permitting Unit Npne r hCarolina atrrra!!� North Carolina Division of Water Quality .1617 Mail Service Center Raleigh, NC 27699-1617 Phone (919) 733-7015 Customer Service Internet: h2o.enr.state.nc.us 512 N. Salisbury St. Raleigh, NC 27604 PAX (919) 733-2496 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer— 50% Recycled110% Post Consumer Paper STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY PERMIT NO. NCS000350 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, EDGECOMB.E GENCO, LLC is hereby authorized to discharge stormwater from a facility located at EDGECOMBE GENCO, LLC SITE ROUTE 2, STATE ROAD 1400 BATTLEBORO EDGECOMBE COUNTY to receiving waters designated as an unnamed tributary to Beech Creek, a class C NSW stream, in the Tar -Pamlico River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, I1, III, IV, V, and VI hereof. This permit shall become effective March 17, 2006. This permit and the authorization to discharge shall expire on April 30, 2007. Signed this day March 17, 2006. Alan W. Klimek, Director Division of Water Quality By Authority of the Environmental Management Commission Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality September 5, 2006 EDGECOMBE GENCO, LLC-BATTLEBORO ATTN: SETH CARTER, OR SUCCESSOR PO BOX 370 BATTLEBORO3 NC 27809 Subject: NPDES Stormwater Permit Renewal Edgecombe Genco, LLC-Battleboro Permit Number NCS000350 Edgecombe County Dear Permittee: Your facility is currently covered for stormwater discharge under NPDES Permit NCS000350. This permit expires on April 30, 2007. North Carolina Administrative Code (15A NCAC 2H.0105(e)) requires that an application for permit renewal be filed at least 180 days prior to expiration of the current permit. In order to assure your continued coverage under your permit, you must apply to the Division of Water Quality (DWQ) for renewal of your permit. To make this renewal process easier, we are informing you in advance that your permit will be expiring. Enclosed you will find an individual permit renewal application form, supplemental information request, and Stormwater Pollution Prevention Plan certification. Filing the application form along with the requested supplemental information will constitute your application for renewal of your permit. As stated above, the application form must be completed and returned along with all requested information by in order for the permit to be renewed by April 30, 2007. Failure to request renewal by may result in a civil assessment of at least $500.00. Larger penalties may be ssessed depending on the delinquency of the request. Discharge of stormwater from your facility without overage under a valid stormwater NPDES permit would constitute a violation of NCGS 143-215.1 and could esult in assessments of civil penalties of up to $25,000 per day. Fyou have any questions regarding the permit renewal procedures please contact Mike Randall of the Stormwater 'ermitting Unit at (919) 733-5083, ext. 545. Sincerely, Bradley Bennett, Supervisor Stormwater Permitting Unit Central Files Sto`rmwater'P�il�tin nttU Files Raleigh; Regional Office � J�a pia Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 Phone (919) 733-5083 Customer Service y.ncwaterquality.ora Location: 512 N. Salisbury St. Raleigh, NC 27604 Fax (919) 733-9612 1-877-623-6748 1tnfty/Affirmafive Actlon Employer— 50% Ratycledl10% Post Consumer Paper NCS000350 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY PERMIT TO DISCHARGE STORMWATER UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provisions of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Cogentrix Energy, Inc. is hereby authorized to discharge stormwater from a facility located at Cognetrix of Rocky Mount Route 2, State Road 1400 Battleboro Edgecombe County to receiving waters designated as an unnamed tributary to Beech Creek, a class C NSW stream, in the Tar Pamlico River Basin in accordance with the discharge limitations, monitoring requirements, and other conditions set forth in Parts I, I1, III, IV, V and VI hereof. This permit shall become effective May 1, 2002. This permit and the authorization to discharge shall expire at midnight on April 30, 2007 Signed this day April 12, 2002. DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT for Gregory J.Thorpe, Ph.D., Acting Director Division of Water Quality By the Authority of the Environmental Management Commission 16 Ole a r 06 Permit No. NCS000350 Y TABLE OF CONTENTS PART I INTRODUCTION Section A: Individual Permit Coverage Section B: Permitted Activities Section C: Location Map PART II MONITORING, CONTROLS, AND LIMITATIONS FOR PERMITTED DISCHARGES Section A: Stormwater Pollution Prevention Plan Section B: Analytical Monitoring Requirements Section C: Qualitative Monitoring Requirements Section D: On -Site Vehicle Maintenance Monitoring Requirements PART III STANDARD CONDITIONS Section A:' Compliance and Liability 1. Compliance Schedule 2. Duty to Comply 3. Duty to Mitigate 4. CiviI and Criminal Liability 5. Oil and Hazardous Substance Liability 5. Property Rights 7. Severability 8. Duty to Provide Information 9. Penalties for Tampering 10. Penalties for Falsification of Reports Section B: General Conditions 1. Individual Permit Expiration 2. Transfers I *• *1* Permit No. NCS000350 3. Signatory Requirements 4. Individual Permit Modification, Revocation and Reissuance, or Termination 5. Permit Actions Section C: Operation and Maintenance of Pollution Controls 1. Proper Operation and Maintenance 2. Need to Halt or Reduce Not a Defense 3. Bypassing of Stormwater Control Facilities Section D: Monitoring and Records 1. Representative Sampling 2. Recording Results 3. Flow Measurements 4. Test Procedures 5. Representative Outfall 6. Records Retention 7. Inspection and Entry Section E: Reporting Requirements 1. Discharge Monitoring Reports 2. Submitting Reports 3. Availability of Reports 4. Non-Stormwater Discharges 5. Planned Changes 6. Anticipated Noncompliance 7. Bypass 8. Twenty-four Hour Reporting 9. Other Noncompliance 10. Other Information PART IV LIMITATIONS REOPENER PART V ADMINISTERING AND COMPLIANCE MONITORING FEE REQUIREMENTS PART VI DEFINITIONS M 910 •0 Permit No. NC5000350 PART I INTRODUCTION SECTION A: INDIVIDUAL PERMIT COVERAGE During the period beginning on the effective date of the permit and lasting until expiration, the pen-nittee is authorized to discharge stormwater associated with industrial activity. Such discharges shall be controlled, limited and monitored as specified in this permit. SECTION B: PERMITTED ACTIVITIES Until this permit expires or is modified or revoked, the permittee is authorized to discharge stormwater to the surface waters of North Carolina or separate storm sewer system which has been adequately treated and managed in accordance with the terms and conditions of this individual permit. All discharges shall be in accordance with the conditions of this permit. Any other point source discharge to surface waters of the state is prohibited unless it is an allowable non-stormwater discharge or is covered by another permit, authorization or approval. This permit does not relieve the permittee from responsibility for compliance with any other applicable federal, state, or local law, rule, standard, ordinance, order, judgment, or decree. Part I Page I of 2 go 0 • Permit No. NCS000350 PART II MONITORING, CONTROLS, AND LIMITATIONS FOR PERMITTED DISCHARGES SECTION A: STORMWATER POLLUTION PREVENTION PLAN The permittee shall develop a Stormwater Pollution Prevention Plan, herein after referred to as the Plan. This Plan shall be considered public information in accordance with Part III, Standard Conditions, Section E, Paragraph 3 of this individual permit. The Plan shall include, at a minimum, the following items: 1. Site Plan. The site plan shall provide a description of the physical facility and the potential pollutant sources which may be expected to contribute to contamination of stormwater discharges. The site plan shall contain the following: (a) A general location map (USGS quadrangle map or appropriately drafted equivalent map), showing the facility's location in relation to transportation routes and surface waters, the name of the receiving water(s) to which the stormwater outfall(s) discharges, or if the discharge is to a municipal separate storm sewer system, the name of the municipality and the ultimate receiving waters; and accurate latitude and longitude of the point(s) of discharge. (b) A narrative description of storage practices, loading and unloading activities, outdoor process areas, dust or particulate generating or control processes, and waste disposal practices. (c) A site map drawn to scale with the distance legend indicating location of industrial activities (including storage of materials, disposal areas, process areas and loading and unloading areas), drainage structures, drainage areas for each outfall and activities occurring in the drainage area, building locations, existing BMPs and impervious surfaces, and the percentage of each drainage area that is impervious. For each outfall, a narrative description of the potential pollutants which could be expected to be present in the stormwater discharge. (d) A list of significant spills or leaks of pollutants that have occurred at the facility during the 3 previous years and any corrective actions taken to mitigate spill impacts. (e) Certification that the stormwater outfalls have been evaluated for the presence of non-stormwater discharges. The certification statement will be signed in accordance with the requirements found in Part III, Standard Conditions, Section B, Paragraph 3. 2. Stormwater Management Plan. The stormwater management plan shall contain a narrative description of the materials management practices employed which control or minimize the exposure of significant materials to stormwater, including structural and nonstructural measures. The stormwater management plan, at a minimum, shall incorporate the following: Part II Page I of 6 040 •0 Permit No. NCS000350 (a) Feasibility Study. A review of the technical and economic feasibility of changing the methods of operations and/or storage practices to eliminate or reduce exposure of materials and processes to stormwater. Wherever practical, the permittee shall prevent exposure of all storage areas, material handling operations, and manufacturing or fueling operations. In areas where elimination of exposure is not practical, the stormwater management plan shall document the feasibility of diverting the stormwater runoff away from areas of potential contamination. (b) Secondary Containment Schedule. A schedule to provide secondary containment for bulk storage of liquid materials, storage of Section 313 of Title III of the Superfund Amendments and Reauthorization Act (SARA) water priority chemicals, or storage of hazardous substances to prevent leaks and spills from contaminating stormwater runoff. If the secondary containment devices are connected directly to stormwater conveyance systems, the connection shall be controlled by manually activated valves or other similar devices [which shall be secured with a locking mechanism] and any stormwater that accumulates in the containment area shall be at a minimum visually observed for color, foam, outfall staining, visible sheens and dry weather flow, prior to release of the accumulated stormwater. Accumulated stormwater shall be released if found to be uncontaminated by the material stored within the containment area. Records documenting the individual making the observation, the description of the accumulated stormwater and the date and time of the release shall be kept for a period of five years. (c) BMP Summary. A narrative description shall be provided of Best Management Practices (BMPs) to be considered such as, but not limited to, oil and grease separation, debris control, vegetative filter strips, infiltration and stormwater detention or retention, where necessary. The need for structural BMPs. shall be based on the assessment of potential of sources to contribute significant quantities of pollutants to stormwater discharges and data collected through monitoring of stormwater discharges. 3. Spill Prevention and Response Plan. The Spill Prevention and Response Plan (SPRP) shall incorporate an assessment of potential pollutant sources based on a materials inventory of the facility. Facility personnel (or team) responsible for implementing the SPRP shall be identified. A responsible person shall be on -site at all times during facility operations that have the potential to contaminate stormwater runoff through spills or exposure of materialsassociated with the facility operations. The SPRP must be site stormwater specific. Therefore, a SPCC plan may be a component of the SPRP, but may not be sufficient to completely address the stormwater aspects of the SPRP. The common elements of the SPCC with the SPRP may be incorporated by reference into the SPRP. 4. Preventative Maintenance and Good Housekeeping Program. A preventative maintenance program shall be developed. The program shall document schedules of inspections and maintenance activities of stormwater control systems, plant equipment and systems. Inspection of material handling areas and regular cleaning schedules of these areas shall be incorporated into the program. Part lI Page 2 of 6 *I* so Permit No. NCS000350 S. Employee Training. Training schedules shall be developed and training provided at a minimum on an annual basis on proper spill response and cleanup procedures and preventative maintenance activities for all personnel involved in any of the facility's operations that have the potential to contaminate stormwater runoff. Facility personnel (or team) responsible for implementing the training shall be identified. 6. Responsible. Party. The Stormwater Pollution Prevention Plan shall identify a specific position(s) responsible for the overall coordination, development, implementation, and revision to the Plan. Responsibilities for all components of the Plan shall be documented and position assignments provided. 7. Plan Amendment. The permittee shall amend the Plan whenever there is a change in design, construction, operation, or maintenance which has a significant effect on the potential for the discharge of pollutants to surface waters. The Stormwater Pollution Prevention Plan shall be reviewed and updated on an annual basis. The Director may notify the permittee when the Plan does not meet one or more of the minimum requirements of the permit. Within 30 days of such notice, the permittee shall submit a time schedule to the Director for modifying the Plan to meet minimum requirements. The permittee shall provide certification in writing (in accordance with Part III, Standard Conditions, Section B, Paragraph 3) to the Director that the changes have been made. 8. Facility Inspection Program. Facilities are required to inspect all stormwater systems on at least a semiannual schedule, once in the fall (September -November) and once in the spring (April - June). The inspection and any subsequent maintenance activities performed shall be documented, recording date and time of inspection, individual(s) making the inspection and a narrative description of the facility's stormwater control systems, plant equipment and systems. Records of these inspections shall be incorporated into the Stormwater Pollution Prevention Plan. Stormwater discharge characteristic monitoring as required in Part II of this permit shall be performed in addition to facility inspections. 9. Implementation. The permittee shall document all monitoring, measurements, inspections and maintenance activities and training provided to employees, including the log of the sampling data and of activities taken to implement BMWs associated with the industrial activities, including vehicle maintenance activities. Such documentation shall be kept on -site for a period of five years and made available to the Director or his authorized representative immediately upon request. Part It Page 3 of 6 r 040 Per mit No NCS000350 SECTION B: ANALYTICAL MONITORING REQUIREMENTS During the period beginning on the effective date of the permit and lasting until expiration, the permittee is authorized to discharge stormwater subject to the provisions of this permit. Analytical monitoring of stormwater discharges shall be performed as specified below in Table 1. All analytical monitoring shall be performed during a representative storm event. The required monitoring will result in a minimum of 7 analytical samplings being conducted over the term of the permit at each stormwater discharge outfall (SDO). The permittee shall complete the minimum 7 analytical samplings in accordance with the schedule specified below in Table 2. Table 1. Analytical Monitoring Re uirements Discharged` lj, �'0.- Me ur�m�nt�FregueW1t M G Sample Saaple Chai�aeter sties .. Untts .. �$ .: ,. y a Eo {zone Total Suspended Solids mg/1 Annually year 1, 2, 3 Grab SDO guarterly year 4 Chemical Oxygen Demand mg/1 Annually year 1, 2, 3 Grab SDO Quarterly year 4 Total Rainfall4 inches Annually year 1, 2, 3 _Quarterly year 4 Event Duration4 minutes Annually year 1, 2, 3 _ Quarterly year 4 Total Flow4 MG Annually year 1, 2, 3 _ SDO Quarterly year 4 Footnotes: 1 Measurement Frequency: Once per year during years 1, 2, and 3 of the permit term. Each quarter during the 4'h year of the permit term. A year is defined as the 12 month period beginning on the month and day of issuance of the Permit. See Table 2 for schedule of monitoring periods. 2 If the stormwater runoff is controlled by a stormwater detention pond, a grab sample of the discharge from the pond shall be collected within the first 30 minutes of discharge. If the detention pond discharges only in response to a storm event exceeding a ten year design storm, then no analytical monitoring is required and only qualitative monitoring shall be performed. 3 Sample Location: Samples shall be collected at each stormwater discharge outfall (SDO) unless representative outfall status has been granted. 4 For each sampled representative storm event the total precipitation, storm duration, and total flow must be monitored. Total flow shall be either; (a) measured continuously, (b) calculated based on the amount of area draining to the outfall, the amount of built -upon (impervious) area, and the total amount of rainfall, or (c) estimated by the measurement of flow at 20 minute intervals during the rainfall event. Table 2 Monitoring schedule Part II Page 4 of 6 Ole 00 Permit No. NCS000350 r o 'iVlonttonrtg pertod�4 ,: a , �.::Tr _'Sample Number m x , g Start4 „ ` ``- Irnd " r y Year 1 1 May 1, 2002 April 30, 2003 Year 2 2 May 1, 2003 April 30, 2004 Year 3 3 May 1, 2004 April 30, 2005 Year 4 - V quarter 4 May 1, 2005 July 31, 2005 Year 4 - 2'd quarter 5 August 1, 2005 October 31, 2005 Year 4 - 3"' quarter 6 November 1, 2005 January 31, 2006 Year 4 - 4"' quarter 7 February 1, 2006 April 30, 2006 SECTION C: QUALITATIVE MONITORING REQUIREMENTS Qualitative monitoring requires a visual inspection of each stormwater outfall regardless of representative outfall status and shall be performed as specified below in Table 3. Qualitative monitoring is for the purpose of evaluating the effectiveness of the Stormwater Pollution Prevention Plan (SPPP) and assessing new sources of stormwater pollution. No analytical tests are required. Qualitative monitoring of stormwater outfalls does not need to be performed during a representative storm event. In the event an atypical condition is noted at a stormwater discharge outfall, the Permittee shall document the suspected cause of the condition and any actions taken in response to the discovery. This documentation will be maintained with the Stormwater Pollution Prevention Plan. All qualitative monitoring will be performed twice per year, once in the spring (April - June) and once in the fall (September - November). Table 3. Qualitative Monitoring Requirements Discharge Characteristics :; yy,, Fr equency, '.. .ti.: i('�C's MoliltdM,�* ig '01t ati4n1 Color Semi -Annual SDO Odor Semi -Annual SDO Clarity Semi -Annual SDO Floating Solids Semi -Annual SDO Suspended Solids Semi -Annual SDO Foam Semi -Annual SDO Oil Sheen Semi -Annual SDO Other obvious indicators of stormwater pollution Semi -Annual SDO Footnotes: Part 11 Page 5 of 6 041 040 Permit No. NCS000350 I Monitoring Location: Qualitative monitoring shall be performed at each stormwater discharge outfall (SDO) regardless of representative outfall status. SECTION D: ON -SITE VEHICLE MAINTENANCE MONITORING REQUIREMENTS Facilities which have any vehicle maintenance activity occurring on -site which uses more.than 55 gallons of new motor oil per month when averaged over the calendar year shall perform analytical monitoring as specified below in Table 4. This monitoring shall be performed at all outfalls which discharge stormwater runoff from vehicle maintenance areas. All analytical monitoring shall be performed during a representative storm event. The required monitoring will result in a minimum of 7 analytical samplings being conducted over the term of the permit at each stormwater discharge outfall (SDO) which discharges stormwater runoff from vehicle maintenance areas. The permittee shall complete the minimum 7 analytical samplings in accordance with the schedule specified in Table 2 (Part lI, Section B). Table 4. Analytical Monitor in Re uirements for On -Site Vehicle Maintenance Dtshar kx�T�` g Uhara terishcs r ` Unt Measuremen Sample Same c� ocatran pH standard Annually year 1, 2, 3 Grab SDO Quarterly year 4 Oil and Grease mgll Annually year 1, 2, 3 Grab SDO Quarterly year 4 Total Suspended Solids mg/1 Annually year 1, 2, 3 Grab SDO Quarterly year 4 New Motor Oil Usage gallons/month Annually year 1, 2, 3 Estimate - QuarterIX year 4 Total Flow4 MG Annually year 1, 2, 3 Grab SDO Quarterly year 4 Footnotes: I Measurement Frequency: Once per year during years 1, 2, and 3 of the permit term. Each quarter during the e year of the permit term. A year is defined as the 12 month period beginning on the month and day of issuance of the Permit. See Table 2 for schedule of monitoring periods. 2 If the stormwater runoff is controlled by a stormwater detention pond, a grab sample of the discharge from the pond shall be collected within the first 30 minutes of discharge. If the detention pond discharges only in response to a storm event exceeding a ten year design storm, then no analytical monitoring is required and only qualitative monitoring shall be performed. 3 Sample Location: Samples shall be collected at each stormwater discharge outfall (SDO) that discharges stormwater runoff from area(s) where vehicle maintenance activities occur. 4 Total flow shall be; (a) measured continuously, (b) calculated based on the amount of area draining to the outfall, the amount of built -upon (impervious) area, and the total amount of rainfall, or (c) estimated by the measurement of flow at 20 minute intervals during the rainfall event. Total precipitation and duration of the rainfall event measured shall result from the sampled representative storm event. Part 11 Page 6 of 6 0 • 00 Permit No. NCS000350 PART III STANDARD CONDITIONS FOR NPDES STORMWATER INDIVIDUAL PERMITS SECTION A: COMPLIANCE AND LIABILITY Compliance Schedule The permittee shall comply with Limitations and Controls specified for stormwater discharges in accordance with the following schedule: Existing Facilities: The Stormwater Pollution Prevention Plan shall be developed and implemented within 12 months of the effective date of the initial permit and updated thereafter on an annual basis. Secondary containment, as specified in Part II, Section A, Paragraph 2(b) of this permit, shall be accomplished within 12 months of the effective date of the initial permit issuance. Proposed Facilities: The Stormwater Pollution Prevention Plan shall be developed and implemented prior to the beginning of discharges from the operation of the industrial activity and be updated thereafter on an annual basis. Secondary containment, as specified in Part II, Section A, Paragraph 2(b) of this permit shall be accomplished prior to the beginning of discharges from the operation of the industrial activity. 2. Duty to Comply The permittee must comply with all conditions of this individual permit. Any permit noncompliance constitutes a violation of the Clean Water Act and is grounds for enforcement action; for permit termination, revocation and reissuance, or modification; or denial of a permit upon renewal application. a. The permittee shall comply with standards or prohibitions established under section 307(a) of the Clean Water Act for toxic pollutants within the time provided in the regulations that establish these standards or prohibitions, even if the permit has not yet been modified to incorporate the requirement. b. The Clean Water Act provides that any person who violates a permit condition is subject to a civil penalty not to exceed $27,500 per day for each violation. Any person who negligently violates any permit condition is subject to criminal penalties of $2,500 to $25,000 per day of violation, or imprisonment for not more than 1 year, or both. Any person who knowingly violates permit conditions is subject to criminal penalties of $5,000 to $50,000 per day of violation, or imprisonment for not more than 3 years, or both. Also, any person who violates a permit condition may be assessed an administrative penalty not to exceed $11,000 per violation with the maximum amount not to exceed $137,500. [Ref: Section 309 of the Federal Act 33 USC 1319 and 40 CFR 122.41(a).] C. Under state law, a daily civil penalty of not more than twenty-five thousand dollars ($25,000) per violation may be assessed against any person who violates or fails to act in accordance with the terms, conditions; or requirements of a permit. [Ref: North Carolina General Statutes 143- 215.6A] d. Any person may be assessed an administrative penalty by the Director for violating section 301, 302, 306, 307, 308, 318, or 405 of the Act; or any permit condition or limitation implementing any of such sections in a permit issued under section 402 of the Act. Administrative penalties for Class I violations are not to exceed $11,000 per violation, with the maximum amount of any Class I penalty assessed not to exceed $27,500. Penalties for Class 11 violations are not to exceed $I 1,000 per day for each day during which the violation continues, with the maximum amount of any Class 11 penalty not to exceed $137,500. Part III Page I of 8 Pages 0 • r , . • Permit No. NCS000350 3. Duty to Mitigate The permittee shall take all reasonable steps to minimize or prevent any discharge in violation of this individual permit which has a reasonable likelihood of adversely affecting human health or the environment. 4. Civil and Criminal Liability Except as provided in Part III, Section C of this permit regarding bypassing of stormwater control facilities, nothing in this individual permit shall be construed to relieve the permittee from any responsibilities, liabilities, or penalties for noncompliance pursuant to NCGS 143-215.3, 143-215.6A, 143-215.613, 143- 215.6C or Section 309 of the Federal Act, 33 USC 1319. Furthermore, the permittee is responsible for consequential damages, such as fish kills, even though the responsibility for effective compliance may be temporarily suspended. Oil and Hazardous Substance Liabilit Nothing in this individual permit shall be construed to preclude the institution of any legal action or relieve the permittee from any responsibilities, liabilities, or penalties to which the permittee is or may be subject to under NCGS 143-215.75 et seq. or Section 311 of the Federal Act, 33 USC 1321. Property Rights The issuance of this individual permit does not convey any property rights in either real or personal property, or any exclusive privileges, nor does it authorize any injury to private property or any invasion of personal rights, nor any infringement of Federal, State or local laws or regulations. Severability The provisions of this individual permit are severable, and if any provision of this individual permit, or the application of any provision of this individual permit to any circumstances, is held invalid, the application of such provision to other circumstances, and the remainder of this individual permit, shall not be affected thereby. Duty to Provide Information The permittee shall furnish to the Director, within a reasonable time, any information which the Director may request to determine whether cause exists for modifying, revoking and reissuing, or terminating the permit issued pursuant to this individual permit or to determine compliance with this individual permit. The permittee shall also furnish to the Director upon request, copies of records required to be kept by this individual permit. Penalties for Tampering The Clean Water Act provides that any person who falsifies, tampers with, or knowingly renders inaccurate, any monitoring device or method required to be maintained under this individual permit shall, upon conviction, be punished by a fine of not more than $10,000 per violation, or by imprisonment for not more than two years per violation, or by both. If a conviction of a person is for a violation committed after a first conviction of such person under this paragraph, punishment is a fine of not more that $20,000 per day of violation, or by imprisonment of not more than 4 years, or both. 10. Penalties for Falsification of Reports The Clean Water Act provides that any person who knowingly makes any false statement, representation, or certification in any record or other document submitted or required to be maintained under this individual Part III Page 2 of 8 Pages 0 • • Permit No. NCS000350 permit, including monitoring reports or reports of compliance or noncompliance shall, upon conviction, be punished by a fine of not more than $10,000 per violation, or by imprisonment for not more than two years per violation, or by both. SECTION B: GENERAUCONDITIONS Individual Permit Expiration The permittee is not authorized to discharge after the expiration date. In order to receive automatic authorization to discharge beyond the expiration date, the permittee shall submit forms and fees as are required by the agency authorized to issue permits no later than 180 days prior to the expiration date. Any permittee that has not requested renewal at least 180 days prior to expiration, or any permittee that does not have a permit after the expiration and has not requested renewal at least 180 days prior to expiration, will be subjected to enforcement procedures as provided in NCGS § 143-2153.6 and 33 USC 1251 et. seq. Transfers This permit is not transferable to any person except after notice to and approval by the Director. The Director may require modification or revocation and reissuance of the permit to change the name and incorporate such other requirements as may be necessary under the Clean Water Act. Permittee is required to notify the Division in writing in the event the permitted facility is sold or closed. 3. SigranatoryRequirements All applications, reports, or information submitted to the Director shall be signed and certified. a. All applications to be covered under this individual permit shall be signed as follows: (1) For a corporation: by a responsible corporate officer. For the purpose of this Section, a responsible corporate officer means: (a) a president, secretary, treasurer or vice president of the corporation in charge of a principal business function, or any other person who performs similar policy or decision making functions for the corporation, or (b) the manager of one or more manufacturing production or operating facilities employing more than 250 persons or having gross annual sales or expenditures exceeding 25 million (in second quarter 1980 dollars), if authority to sign documents has been assigned or delegated to the manager in accordance with corporate procedures. (2) For a partnership or sole proprietorship: by a general partner or the proprietor, . respectively; or (3) For a municipality, State, Federal, or other public agency: by either a principal executive officer or ranking elected official. b. All reports required by the individual permit and other information requested by the Director shall be signed by a person described above or by a duly authorized representative of that person. A person is a duly authorized representative only if: (1) The authorization is made in writing by a person described above; (2) The authorization specified either an individual or a position having responsibility for the overall operation of the regulated facility or activity, such as the position of plant manager, operator of a well or well field, superintendent, a position of equivalent responsibility, or an individual or position having overall responsibility for environmental Part III Page 3 of 8 Pages 0 • •• Permit No. NCS000350 matters for the company. (A duly authorized representative may thus be either a named individual or any individual occupying a named position.); and (3) The written authorization is submitted to the Director. C. Any person signing a document under paragraphs a. or b.-of this section shall make the following certification: 1 certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." 4. Individual Permit Modification Revocation and Reissuance or Termination The issuance of this individual permit does not prohibit the Director from reopening and modifying the individual permit, revoking and reissuing the individual permit, or terminating the individual permit as allowed by the' laws, rules, and regulations contained in Title 40, Code of Federal Regulations, Parts 122 and 123; Title 15A of the North Carolina Administrative Code, Subchapter 2H .0100; and North Carolina General Statute 143-215.1 et. al. 5. Permit Actions The permit may be modified, revoked and reissued, or terminated for cause. The notification of planned changes or anticipated noncompliance does not stay any individual permit condition. SECTION C: OPERATION AND MAINTENANCE OF POLLUTION CONTROLS Proper Opgration and Maintenance The permittee shall at all times properly operate and maintain all facilities and systems of treatment and control (and related appurtenances) which are installed or used by the permittee to achieve compliance with the conditions of this individual permit. Proper operation and maintenance also includes adequate laboratory controls and appropriate quality assurance procedures. This provision requires the operation of back-up or auxiliary facilities or similar systems which are installed by a permittee only when the operation is necessary to achieve compliance with the conditions of this individual permit. 2. Need to Halt or Reduce Not a Defense It shall not be a defense for a permittee in an enforcement action that it would have been necessary to halt or reduce the permitted activity in order to maintain compliance with the condition of this individual permit. Bypassing of Stormwater Control Facilities Bypass is prohibited and the Director may take enforcement action against a permittee for bypass unless: a. Bypass was unavoidable to prevent loss of life, personal injury or severe property damage; and There were no feasible alternatives to the bypass, such as the use of auxiliary control facilities, retention of stormwater or maintenance during normal periods of equipment downtime or dry Part III Page 4 of 8 Pages 90 •. Permit No. NCS000350 weather. This condition is not satisfied if adequate backup controls should have been installed in the exercise of reasonable engineering judgment to prevent a bypass which occurred during normal periods of equipment downtime or preventive maintenance; and The permittee submitted notices as required under, Part I11, Section E of this permit. If the Director determines that it will meet the three conditions listed above, the Director may approve an anticipated bypass after considering its adverse effects. SECTION D: MONITORING AND RECORDS Representative Sampline Samples collected and measurements taken, as required herein, shall be characteristic of the volume and nature of the permitted discharge. Analytical sampling shall be performed during a representative storm event. Samples shall be taken on a day and time that is characteristic of the discharge. All samples shall be taken before the discharge joins or is diluted by any other waste stream, body of water, or substance. Monitoring points as specified in this permit shall not be changed without notification to and approval of the Director. 2. Recording Results For each measurement, sample, inspection or maintenance activity performed or collected pursuant to the requirements of this individual permit, the permittee shall record the following information: a. The date, exact place, and time of sampling, measurements, inspection or maintenance activity; b. The individual(s) who performed the sampling, measurements, inspection or maintenance activity; c. The date(s) analyses were performed; d. The individual(s) who performed the analyses; e. The analytical techniques or methods used; and f. The results of such analyses. 3. Flow Measurements Where required, appropriate flow measurement devices and methods consistent with accepted scientific practices shall be selected and used to ensure the accuracy and reliability of measurements of the volume of monitored discharges. 4. Test Procedures Test procedures for the analysis of pollutants shall conform to the EMC regulations published pursuant to NCGS 143-215.63 et. seq, the Water and Air Quality Reporting Acts, and to regulations published pursuant to Section 304(g), 33 USC 1314, of the Federal Water Pollution Control Act, as Amended, and Regulation 40 CFR 136. To meet the intent of the monitoring required by this individual permit, all test procedures must produce minimum detection and reporting levels and all data generated must be reported down to the minimum detection or lower reporting level of the procedure. Part III Page 5 of 8 Pages 00 00' Permit No. NCS000350 Representative Outfall If a facility has multiple discharge locations with substantially identical stormwater discharges that are required to be sampled, the permittee may petition the Director for representative outfall status. If it is established that the stormwater discharges are substantially identical and the permittee is granted representative outfall status, then sampling requirements may be performed at a reduced number of outfalls. 6. Records Retention Visual monitoring shall be documented and records maintained at the facility along with the Stormwater Pollution Prevention Plan. Copies of analytical monitoring results shall also be maintained on -site. The permittee shall retain records of all monitoring information, including all calibration and maintenance records and all original strip chart recordings for continuous monitoring instrumentation, and copies of all reports required by this individual permit for a period of at least 5 years from the date of the sample, measurement, report or application. This period may be extended by request of the Director at any time. Inspection and Entry The permittee shall allow the Director, or an authorized representative (including an authorized contractor acting as a representative of the Director), or in the case of a facility which discharges through a municipal separate storm sewer system, an authorized representative of a municipal operator or the separate storm sewer system receiving the discharge, upon the presentation of credentials and other documents as may be required by law, to; a. Enter upon the permittee's premises where a regulated facility or activity is located or conducted, or where records must be kept under the conditions of this individual permit; b. Have access to and copy, at reasonable times, any records that must be kept under the conditions of this individual permit; C. Inspect at reasonable times any facilities, equipment (including monitoring and control equipment), practices, or operations regulated or required under this individual permit; and d. Sample or monitor at reasonable times, for the purposes of assuring individual permit compliance or as otherwise authorized by the Clean Water Act, any substances or parameters at any location. SECTION E: REPORTING REQUIREMENTS Discharge Monitoring Reports Samples analyzed in accordance with the terms of this permit shall be submitted to the Division on Discharge Monitoring Report forms provided by the Director. Submittals shall be received by the Division no later than 30 days from the date the facility receives the sampling results from the laboratory. 2. Submitting Reports Duplicate signed copies of all reports required herein, shall be submitted to the following address: Division of Water Quality Water Quality Section ATTENTION: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Part III Page 6 of 8 Pages 0• } _ 0• Permit No. NCS000350 Availabilit_y_of Reports Except for data determined to be confidential under NCGS 143-215.3(a)(2) or Section 308 of the Federal Act, 33 USC 1318, all reports prepared in accordance with the terms shall be available for public inspection at the offices of the Division of Water Quality. As required by the Act, analytical data shall not be considered confidential. Knowingly making any false statement on any such report may result in the imposition of criminal penalties as provided for in NCGS 143-215.6B or in Section 309 of the Federal Act. 4. Non-Stormwater Dischariz If the storm event monitored in accordance with this individual permit coincides with a non-stormwater discharge, the permittee shall separately monitor all parameters as required under the non-stormwater discharge permit and provide this information with the stormwater discharge monitoring report. 5. Planned Changes The permittee shall give notice to the Director as soon as possible of any planned changes at the permitted facility which could significantly alter the nature or quantity of pollutants discharged. This notification requirement includes pollutants which are not specifically listed in the individual permit or subject to notification requirements under 40 CFR Part 122.42 (a). 6. Anticipated Noncompliance The permittee shall give notice to the Director as soon as possible of any planned changes at the permitted facility which may result in noncompliance with the individual permit requirements. 7. BYpas a. Anticipated bypass. If the permittee knows in advance of the need for a bypass, it shall submit prior notice, if possible at least ten days before the date of the bypass; including an evaluation of the anticipated quality and affect of the bypass. b. Unanticipated bypass. The permittee shall submit notice within 24 hours of becoming aware of an unanticipated bypass. 8. Twenty-four Hour Reporting The permittee shall report to the central office or the appropriate regional office any noncompliance which may endanger health or the environment. Any information shall be provided orally within 24 hours from the time the permittee became aware of the circumstances. A written submission shall also be provided within 5 days of the time the permittee becomes aware of the circumstances. The written submission shall contain a description of the noncompliance, and its causes; the period of noncompliance, including exact dates and times, and if the noncompliance has not been corrected, the anticipated time compliance is expected to continue; and steps taken or planned to reduce, eliminate, and prevent reoccurrence of the noncompliance. The Director may waive the written report on a case -by -case basis if the oral report has been received within 24 hours. 9. Other Noncompliance The permittee shall report all instances of noncompliance not reported under 24 hour reporting at the time monitoring reports are submitted. Part III Page 7 of 8 Pages 00 1 010 Permit No. NCS000350 10. Other Information Where the permittee becomes aware that it failed to submit any relevant facts in an application for an individual permit or in any report to the Director, it shall promptly submit such facts or information. Part III Page 8 of 8 Pages *0 F ' • 0 Permit No. NCS000350 PART IV LIMITATIONS REOPENER This individual permit shall be modified or alternatively, revoked and reissued, to comply with any applicable effluent guideline or water quality standard issued or approved under Sections 302(b) (2) (c), and (d), 304(b) (2) and 307(a) of the Clean Water Act, if the effluent guideline or water quality standard so issued or approved: a. Contains different conditions or is otherwise more stringent than any effluent limitation in the individual permit; or b. Controls any pollutant not limited in the individual permit. The individual permit as modified or reissued under this paragraph shall also contain any otber requirements in the Act then applicable. PART V ADMINISTERING AND COMPLIANCE MONITORING FEE REQUIREMENTS The permittee must pay the administering and compliance monitoring fee within 30 (thirty) days after being billed by, the Division. Failure to pay the fee in timely manner in accordance with 15A NCAC 2H .0105(b)(4) may cause this Division to initiate action to revoke the Individual Permit. 1. Act See Clean Water Act. 2. Arithmetic Mean 93 4. PART VI DEFINITIONS The arithmetic mean of any set of values is the summation of the individual values divided by the number of individual values. Allowable Non-Stormwater Discharges This permit regulates stormwater discharges. Non-stormwater discharges which shall be allowed in the stormwater conveyance system are: (a) All other discharges that are authorized by a non-stormwater NPDES permit. (b) Uncontaminated groundwater, foundation drains, air -conditioner condensate without added chemicals, springs, discharges of uncontaminated potable water, waterline and fire hydrant flushings, water from footing drains, flows from riparian habitats and wetlands. (c) Discharges resulting from fire -fighting or fire -fighting training. Best Management Practices (BMPs) Measures or practices used to reduce the amount of pollution entering surface waters. BMPs may take the form of a process, activity, or physical structure. Parts IV, V and VI Page I of 5 00 •0 Permit No. NCS000350 5. Bypass A bypass is the known diversion of stormwater from any portion of a stormwater control facility including the collection system, which is not a designed or established operating mode for the facility. 6. Bulk Storage of Liquid Products Liquid raw materials, manufactured products, waste materials or by-products with a single above ground storage container having a capacity of greater than 660 gallons or with multiple above ground storage containers located in close proximity to each other having a total combined storage capacity of greater than 1,320 gallons. 7. Clean Water Act The Federal Water Pollution Control Act, also known as the Clean Water Act (CWA), as amended, 33 USC 1251, et. seq. 8. 'Division or DWO The Division of Water Quality, Department of Environment and Natural Resources. 9. Director The Director of the Division of Water Quality, the permit issuing authority. 10. EMC The North Carolina Environmental Management Commission, 11. Grab Sample An individual sample collected instantaneously. Grab samples that will be directly analyzed or qualitatively monitored must be taken within the first 30 minutes of discharge. 12. Hazardous Substance Any substance designated under 40 CFR Part 116 pursuant to Section 311 of the Clean Water Act. 13. Landfill A disposal facility or part of a disposal facility where waste is placed in or on land and which is not a land treatment facility, a surface impoundment, an injection well, a hazardous waste long-term storage facility or a surface storage facility. 14. Municipal Separate Storm Sewer S stem A stormwater collection system within an incorporated area of local self-government such as a city or town. 15. Overburden Any material of any nature, consolidated or unconsolidated, that overlies a mineral deposit, excluding topsoil or similar naturally -occurring surface materials that are not disturbed by mining operations. Part VI Page 2 of 5 Pages L F �• Permit No. NCS000350 16. Permittee The owner or operator issued a permit pursuant to this individual permit. 17, Point Source Discharge of Stormwater Any discernible, confined and discrete conveyance including, but not specifically limited to, any pipe, ditch, channel, tunnel, conduit, well, or discrete fissure from which stormwater is or may be discharged to waters of the state. 18. Representative Storm Event A storm event that measures greater than 0.1 inches of rainfall and that is preceded by at least 72 hours in which no storm event measuring greater than 0.1 inches has occurred. A single storm event may contain up to 10 consecutive hours of no precipitation. For example, if it rains for 2 hours without producing any collectable discharge, and then stops, a sample may be collected if a rain producing a discharge begins again within the next 10 hours. 19. Representative Outfall Status When it is established that the discharge of stormwater runoff from a single outfall is representative of the discharges at multiple outfalls, the DWQ may grant representative outfall status. Representative outfall status allows the permittee to perform analytical monitoring at a reduced number of outfalls. 20. Rinse Water Discharge The discharge of rinse water from equipment cleaning areas associated with industrial activity. Rinse waters from vehicle and equipment cleaning areas are process wastewaters and do not include washwaters utilizing any type of detergent or cleaning agent. 21. Secondary Containment Spill containment for the contents of the single largest tank within the containment structure plus sufficient freeboard to allow for the 25-year, 24-hour storm event. 22. Section 313 Water Priority Chemical A chemical or chemical category which: a. Is listed in 40 CFR 372.65 pursuant to Section 313 of Title III of the Superfund Amendments and Reauthorization Act (SARA) of 1986, also titled the Emergency Planning and Community Right - to -Know Act of 1986; b. Is present at or above threshold levels at a facility subject to SARA title III, Section 313 reporting requirements; and C. That meet at least one of the following criteria: (1) , Is listed in Appendix D of 40 CFR part 122 on either Table 11 (organic priority pollutants), Table III (certain metals, cyanides, and phenols) or Table IV (certain toxic pollutants and hazardous substances); (2) Is listed as a hazardous substance pursuant to section 311(b)(2)(A) of the CWA at 40 CFR l 16.4; or (3) Is a pollutant for which EPA has published acute or chronic water quality criteria. Part VI Page 3 of 5 Pages Permit No. NCS000350 23, 24. Severe Property Damage Means substantial physical damage to property, damage to the control facilities which causes them to become inoperable, or substantial and permanent loss of natural resources which can reasonably be expected to occur in the absence of a bypass. Severe property damage does not mean economic loss caused by delays in production. Significant Materials Includes, but is not limited to: raw materials; fuels; materials such as solvents, detergents, and plastic pellets; finished materials such as metallic products; raw materials used in food processing or production; hazardous substances designated under section 101(14) of CERCLA; any chemical the facility is required to report pursuant to section 313 of Title III of SARA; fertilizers; pesticides; and waste products such as ashes, slag and sludge that have the potential to be released with stormwater discharges. 25. Significant Spills 26. 27 28. 29 30. 31 Includes, but is not limited to: releases of oil or hazardous substances in excess of reportable quantities under section 311 of the Clean Water Act (Ref: 40 CFR 110.10 and CFR 117.21) or section 102 of CERCLA (Ref: 40 CFR 302.4). Stormwater Runoff The flow of water which results from precipitation and which occurs immediately following rainfall or as a result of snowmelt. Stormwater Associated with Industrial Activity The discharge from any point source which is used for collecting and conveying stormwater and which is directly related to manufacturing, processing or raw material storage areas at an industrial site. Facilities considered to be engaged in "industrial activities" include those activities defined in 40 CFR 122.26(b)(14). The term does not include discharges from facilities or activities excluded from the NPDES program. Stormwater Pollution Prevention Plan A comprehensive site -specific plan which details measures and practices to reduce stormwater pollution and is based on an evaluation of the pollution potential of the site. Ten Year Design Storm The maximum 24 hour precipitation event expected to be equaled or exceeded on the average once in ten years. Design storm information can be found in the State of North Carolina Erosion and Sediment Control Planning and Design Manual. Total Flow The flow corresponding to the time period over which the entire storm event occurs. Total flow shall be either; (a) measured continuously, (b) calculated based on the amount of area draining to the outfall, the amount of built -upon (impervious) area, and the total amount of rainfall, or (c) estimated by the measurement of flow at 20 minute intervals during the rainfall event. Toxic Pollutant Any pollutant listed as toxic under Section 307(a)(1) of the Clean Water Act. Part VI Page 4 of 5 Pages .. Permit No. 1VCS000350 32. Upset Means an exceptional incident in which there is unintentional and temporary noncompliance with technology based permit effluent limitations because of factors beyond the reasonable control of the permittee. An upset does not include noncompliance to the extent caused by operational error, improperly designed treatment or control facilities, inadequate treatment or control facilities, lack of preventive maintenance, or careless or improper operation. 33, Vehicle Maintenance Activity Vehicle rehabilitation, mechanical repairs, painting, fueling, lubrication, vehicle cleaning operations, or airport deicing operations. 34. Visible Sedimentation Solid particulate matter, both mineral and organic, that has been or is being transported by water, air, gravity, or ice from its site of origin which can be seen with the unaided eye. 35. 25-year, 24 hour storm event The maximum 24-hour precipitation event expected to be equaled or exceeded, on the average, once in 25 years. Part VI Page 5 of 5 Pages