September 20, 2011
Mr. Paul Pearce
Plant Manager
Resinall Corp
Water Street
PO Box 195
Severn, NC 27877
Subject: Compliance Evaluation Inspections
Resinall Corp
NPDES Permit NCS00029Tand
Stormwater Permit NCG500289
Northampton County
Dear Mr. Pearce:
1, Dave Parnell of the Raleigh Regional Office of the Division of Water Quality, conducted two
inspections on September 12, 2011, consisting of the NPDES and Stormwater inspections. I appreciated
your assistance; as well as the assistance of Mr. Bill Lewis, Environmental and Safety Specialist, and
Mr. Henry Boswell, Corporate Regulatory Manager. Please review the attached Basinwide Information
Management System (BIMS) inspection checklists summarizing the inspections.
Below is a list of findings developed from the inspections:
I. NPDES Permit NCG500289 Inspection:
1. The current permit was reissued August 1, 2007 and expires September 30, 2012. Resinall
Corp. produces synthetic resins for graphic arts and the adhesive industry.
2. This facility is permitted to discharge non -contact cooling water, cooling tower and boiler
blowdown, condensate and similar wastewaters, to an unnamed tributary to Kirby's Creek, in
subbasin 30102 of the Chowan River Basin.
Cooling water is being recycled. Boiler blowdown is treated prior to being comingled with
stormwater and discharged at the Outfall 001.
one NhCaro! i na
North Carolina Division of water Quality Raleigh Regional Office Surface Water Protection Phone (919) 791-4200 Customer Service
Inlernet. www.ncwaterquality.org 1628 Mai! Service Center . Raleigh, NC 27699-1628 FAX (919) 788-7159 877-823-6748
An Equal Opportunity/Affirmative Action Employer — 50% Recycled/10% Post Consumer Paper
Resinall Corp Page 2 `
lI, Stormwater Permit NCG000289 Inspection:
1. A list of significant spills occurring in the last three years is included as a part of the
Stormwater Pollution Prevention Plan. Documentation for specific years would be a more
efficient way of recording future significant spills.
2. Secondary containment is required and used extensively at this facility. Secondary
containment was inspected during the tour of the facility and was found to be compliant.
3. Analytical and qualitative monitoring results were reviewed and found to be compliant with
the permit.
4. Both outfalls were inspected and were in compliance with the, permit.
The treatment system is considered to be in compliance with the NPDES permit, and the facility is also
in compliance with the general stormwater permit, at the time of these inspections. If you have any
questions concerning this report, please do not hesitate to contact me at 919-791-4200.
Sincerely,
JA.,-e, ?lVt4
Dave Parnell
Environmental Specialist
Raleigh Regional Office
Attachment: CEI Inspection Reports
cc: Central Files
SWP/RRO files
Compliance Inspection Report
Permit: NCS000292 Effective: 05/21/07 Expiration: 05/20/12 Owner: Resinall Corporation
SOC: Effective: Expiration: Facility: Resinall Corporation
County: Northampton
302 N Water St
Region: Raleigh
Severn NC 27877
Contact Person: Henry G Boswell Title: Phone: 919-585-1445
Directions to Facility:
System Classifications:
Primary ORC: Certification: Phone:
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Inspection Date: 0911212011 Entry Time: 01:00 PM Exit Time: 02:15 PM
Primary Inspector: David R Parnell Phone: 919-791-4260
Secondary Inspector(s):
Reason for Inspection: Routine
Permit Inspection Type: Stormwater Discharge, Individual
Facility Status: ■ Compliant ❑ Not Compliant
Question Areas:
Storm Water
(See attachment summary)
Inspection Type: Compliance Evaluation
Page: 1
• • 1 i: . �I
Permit: NCS000292
Inspection Date: 0911212011
Inspection Summary:
Owner - Facility: Resinall Corporation
inspection Type: Compliance Evaluation
Reason for Visit: Routine
Page: 2
Permit: NCS000292 Owner - Facility: Resinall Corporation
Inspection Date: 09/12/2011 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Stormwater Pollution Prevention Plan Yes No NA NE
Does the site have a Stormwater Pollution Prevention Plan?
■
❑
❑
❑
# Does the Plan include a General Location (USGS) map?
■
❑
❑
❑
# Does the Plan include a "Narrative Description of Practices"?
■
❑
❑
❑
# Does the Plan include a detailed site map including outfall locations and drainage areas?
■
❑
❑
❑
# Does the Plan include a list of significant spills occurring during the past 3 years?
■
❑
❑
❑
# Has the facility evaluated feasible alternatives to current practices?
■
❑
❑
❑
# Does the facility provide all necessary secondary containment?
■
❑
❑
❑
# Does the Plan include a BMP summary?
■
❑
❑
❑
# Does the Plan include a Spill Prevention and Response Plan (SPRP)?
■
Cl
❑
❑
# Does the Plan include a Preventative Maintenance and Good Housekeeping Plan?
■
❑
❑
❑
# Does the facility provide and document Employee Training?
■
❑
❑
❑
# Does the Plan include a list of Responsible Party(s)?
■
❑
❑
❑
# Is the Plan reviewed and updated annually?
■
❑
❑
❑
# Does the Plan include a Stormwater Facility Inspection Program?
■
❑
❑
❑
Has the Stormwater Pollution Prevention Plan been implemented?
■
❑
❑
❑
Comment:
Qualitative Monitoring
Yes
No
NA
NE
Has the facility conducted its Qualitative Monitoring semi-annually?
■
❑
❑
❑
Comment:
Analytical Monitoring Yes No NA NE
Has the facility conducted its Analytical monitoring? ■ ❑ ❑ ❑
# Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ ■ ❑
Comment:
Permit and Outfalls Yes No NA NE
# Is a copy of the Permit and the Certificate of Coverage available at the site? 0000
# Were all outfalls observed during the inspection? ■ ❑ ❑ ❑
# If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ ■ ❑
# Has the facility evaluated all illicit (non stormwater) discharges? ■ ❑ ❑ ❑
Comment:
Page: 3
0
0
• ANALYSIS REQUEST AND
4 CHAIN OF CUSTODY RECORD
0[q
American Tesling Technologies, Inc.
J
u American Testing Technologies, Inc.
; v1350 %me Avenue Akron, OH 44310
Ile: wwwAmerlcanTestingTechnvlogfes.com
o T Free: 877-634-9906 Phone: (330) 634-9906
F - �. Fax: (330) 634-9907
PROJECT REFERENCE
PROJECT NO-
PROJECT LOCATION
(STATE)
MATROK
TYPE
9: !>ti 'n
r} y R ED AI�LYSIs
PARE
pR GT R -
P.O. NUMEIER ci �� 0
CONTRACT No,
ca
o
3
y
0
a
o z
o
-'
oc
o
Q
8
N
o
p
o
a,
a z
f
r
+y
.r
r
s
�T �i
`C
4;
�1 p
,
'c7 1A
F-
.?� t
O
_
Z-
TF
a
�d N
��
q
_ J
4 l�
L Q
STANDARD REPORT
DELIVERY
DATE DUE
EXPEDITED REPORT
DELIVERY
(SURCHARGE) CD
DATE DUE
CJfNT (SITE)
CIENTPHONE
I!�
CLIENT FAX
zhsv -i3��
NAME
r -
SIl'� lk iG(; O VO
CLIENT E-MAIL
��(t `}
�►i2.�l3fsP'resin lL,c�en
CLI ADDRESS ,
SU
I
NUMBER OF COOLERS SUBMITTED
PER SHIPMENT:
-
SAMPLE IDENTIFICATION
NUMBER OF CONTAINERS SUBMITTED
REMARitS
TIME
10' 30
PQams.s st WAte-g—v�aRt19-
tDMATSAMPLE
- A -05
1
ID:3O►�
it0Ce" WA4k l AfQ
✓
v
RELINQ HE . ( RE)
DATE
4 ri
TIME
3:3�
RELI^�D,ISH BY: (SIGNATURE)
q)
DATE
asr h
TIME
WO
RELINQUISHED W. {SIGNATURE)
DATE
TIME
RECEIVED W. [SIGNATURE)
DATE
TIME
RECEIVED W. (SIGNATURE)
DATE
TIME
RECEIVED W. I&TAAwQ
DATE
TIME
LABORATORY USE ONLY
RECEiYED FOR LABAORAT W.
ISIGRATURE) -• --
rr .r1
DATE
/ I ,
TIME CUSTODY INTACT
] r. I ,, YES O
1 _) �' NO O
CUSTODY
SEAL N0.
A.T.T.
LOG No.
f r• 11i'-'f,
LABORATORY REMARKS
! r ORIGINAL - RETURN TO LABORATORY WITH 5AN[PLE(S)
i 11
Resinal Corporation
Attn: Bill Lewis
P.O. Box 195
Severn, NC 27877
•
American Testing Technologies, Inc.
Date Received: 0511812011
Date Reported: 05/28/2011
Date Collected: 05/17/2011
Client 1D Number: Process Waste Water- After
Laboratory ID N6mber:051811-07
Parameter
Results u L
Method
Date of Analysis.
Ammonia
140
350.2
05/24/2011
Toluene
<5.0
8260
05/25/2011
Benzcne
<5,0
8260
05/25/2011
Ethylbenzene
<5.0
8260
05/25/2011
lsopropylbenzene
<5.0
8260
05/25/2011
Naphthalene
<5.0
8260
05/25/2011
Styrene
<5.0
8260
05/25/2011
1.2,4-Trimcthyibenzene
<5.0
8260
05/25/2011
Xylenes
<5.0
8260
05/25/2011
Dicyclopentadiene
< 10
8270
05/26/2011
Maleic anhydride
< 10
8270
05/26/2011
Formaldehyde ;
< 500
3500
05/26/2011
Final
La
Toll Free: 877-634-9906
reviewed by:
1350 Home Avenue Akron, OH 44310
Phone: (330)634-9906 Fax: (330) 634-9907 Website: www.AmerlcanTestingTechnologies.com
•IN-3-KW
M-0
WAVUVft
NCDEENR
North Carolina Department of Environment and Natural Resources
Division of Water Quality
Beverly Eaves Perdue Coleen H. Sullins
Governor Director
September 25, 2009
Mr. Henry Boswell
Resinall Corporation
Water Street
P.O. Box 195
Severn, NC 27877
Subject: Compliance Evaluation Inspection 9/22/2009
Stormwater Permit No. NCGO00289
Resinall Corporation
Severn, NC
Northampton County
Dear Mr. Boswell:
Dee Freeman
Secretary
Thank you for the assistance provided by you, Bill Lewis and Bobby Bridgers during the inspection on
September 22, 2009. The plant was in compliance. Please see the attached inspection checklist for
details. While biocide is used in the cooling tower, the water is recycled rather than being discharged.
Boiler blowdown is pH adjusted before joining the stormwater conveyance.
If you have comments or questions about this inspection, please contact me at 919-791-4200.
Sincerely,
4 Myr A. Nisely
Environmental Chemist
Raleigh Regional Office
cc: RRO/SWP files
Central Files
N4=1111
one hCarolina
North Carolina Division of Water Quality Raleigh Regional Office Surface Water Protection Phone (919) 791.4200 Customer Service
Internet: www.ncwaterquality.org 1628 Mail service Center Raleigh, NC 27690-1628 FAX (919) 788-7159 877.623-6748
An Equal Opportunity/Affirmative Action Employer — 50% Recycled110% Post Consumer Paper
United States Environmental Protectlon Agency
Form Approved.
EPA Washington, D.C. 20480
oMe No. 2040-0057
Water Compliance Inspection Report
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDE8 yr/mo/day Inspection Type Inspector Fac Type
1 U z f5I 31 NCG500289 `11 121 09/09/22 117
�--r tJ
1alnl 19Ict 20U
tJ IJ
Remarks
211111111111i111111lllllllll_II_IIIIII.11111111111116
Inspection Work Days Facility Self -Monitoring Evaluation Rating 81 QA
-------
671 169 70 U 71 I I 72 UN
73 L_L,_I } � 74 75 80
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES permit Number)
Entry Time/Date
Permit Effective Date
Resinall Corporation
12:55 PM 09/09/22
07/08/01
Exit Time/Date
Permit Expiration Date
302 N Water St
Severn NC 27877
02:00 PM 09/09/22
12/07/31
Names) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
Other Facility Data
Name, Address of Responsible Of#iciaiMtle/Phone and Fax Number
ontaed
Henry G Boswell,302 N Water St Severn NC 27877//919-585-1445/2525850U
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit ■ Records/Reports
Section D: Summary of Find in/Comments Attach additional sheets of narrative and checklists a$ necessa
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phons and Fax Numbers Date
Myrl Nisely RRO WQ//919-791-4200/
]gnat re of Manage ant Q A Z�evi'qAgency/0 fice/Phone and Fax Numbers Date
� v 7
EPA Form 343 (Rev 9-94) Previous editions are obsolete.
Page # 1
Permit: NCG500289
Owner -Facility: Resinall Corporation
Inspection Date: 09/22/2009
Inspection Type: Compliance Evaluation
Permit
Yes
No NA
NE
(If the present permit expires in B months or less). Has the permittee submitted a new application?
❑
❑ ■
❑
Is the facility as described in the permit?
■
❑ ❑
❑
# Are there any special conditions for the permit?
❑
■ ❑
❑
Is access to the plant site restricted to the general public?
■
Cl ❑
❑
Is the inspector granted access to all areas for inspection?
■
❑ ❑
❑
Comment:
Page # 3
NPDES yr/mo/day Inspection Type I
31 NCG500289 12I 09/09/22 I17------18UC
I Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Boiler blowdown and Cooling Tower are covered by this permit. A biocide is used in the cooling tower, but
the water is recycled, so there is no discharge. Boiler blowdown is pH adjusted in a pond before it enters
the stormwater ditch above Outfall 001. Measurements are carried out by field certified personnel from the
plant laboratory.
Page # 2
AMER
North Carolina Department of Environment and Natural Resources
Beverly Eaves Perdue
Governor
Mr. Henry Boswell
Resinail Corporation
Water Street
P.O. Box 195
Severn, NC 27877
Dear Mr. Boswell:
Division of Water Quality
Coleen H. Sullins
Director
September 25, 2009
Subject: Compliance Evaluation Inspection 9/22/2009
Stormwater Permit No. NCS000292
Resinall Corporation
Sevem, NC
Northampton County
Dee Freeman
Secretary
Thank you for the assistance provided by you, Paul Pearce, Bill Lewis and Bobby Bridgers during the
inspection on September 22, 2009. The plant was in compliance. Please see the attached inspection
checklist for further detail.
The Stormwater Pollution Prevention Plan had been updated recently. Monitoring is being done as
required and values were in compliance. It was noted that within a few days the railroad track will be
relocated, thus allowing the installation of a section of fence presently missing because of the inadequate
distance. This will improve plant security.
If you have comments or questions about this inspection, please contact me at 919-791-4200.
Sincerely,
(� Li
M A. Nisely
Environmental Chemist
Raleigh Regional Office
cc: RRO/SWP files
Central Files
1JJae hCarohna
Nak a!!y
North Carolina Division of Water Quality Raleigh Regional Office Surface Water Protection Phone (919) 791-4200 Customer Service
internet: www.newaterquality.org 1828 Mail Service Center ' Raleigh, NC 27609-1628 FAX (919) 788-7159 877-623-6748
An Equal Opportunity/Affirmative Action Employer— 50% Recyclett110% Post Consumer Paper,
Compliance Inspection Report
Permit: NCS000292 Effective: 05/21/07 Expiration: 05/20/12 Owner: Resinall Corporation
SOC: Effective: Expiration: Facility: Resinall Corporation
County: Northampton 302 N Water St
Reglon: Raleigh
Severn NC 27877
Contact Person: Henry G Boswell Title: Phone: 919-585-1445
Directions to Facility:
System Classifications:
Primary ORC: - _ — Certification: Phone:
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Inspection Hate: 09/2212009 Entry Time: 12:55 PM
Primary Inspector: Myrl Nisely
Secondary Inspector(s):
Reason for Inspection: Routine
Permit Inspection Type: Stormwater Discharge, Individual
Facility Status: ■ Compliant ❑ Not Compliant
Question Areas:
Storm Water
(See attachment summary)
Exit Time: 02.00 PM
Phone: 919-791-4200
Inspection Type: Compliance Evaluation
Page: 1
Permit: NCS000292 Owner - Facility: Resinall Corporation
Inspection Date: 0912212009 Inspection Type: Compliance Evaluation
Reason for Visit: Routine
Stormwater Pollution Prevention Plan
Yes
No
NA
NE
Does the site have a Stormwater Pollution Prevention Plan?
■
❑
❑
❑
# Does the Plan include a General Location (USGS) map?
■
❑
❑
❑
# Does the Plan include a "Narrative Description of Practices"?
■
❑
❑
❑
# Does the Plan include a detailed site map including outfall locations and drainage areas?
■
❑
❑
❑
# Does the Plan include a list of significant spills occurring during the past 3 years?
■
❑
❑
❑
# Has the facility evaluated feasible alternatives to current practices?
■
❑
❑
❑
# Does the facility provide all necessary secondary containment?
■
❑
❑
❑
# Does the Plan include a BMP summary?
■
❑
❑
❑
# Does the Plan include a Spill Prevention and Response Plan (SPRP)?
■
❑
❑
❑
# Does the Plan include a Preventative Maintenance and Good Housekeeping Plan?
■
❑
❑
❑
# Does the facility provide and document Employee Training?
■
❑
❑
❑
# Does the Plan include a list of Responsible Party(s)?
■
❑
❑
❑
# Is the Plan reviewed and updated annually?
■
❑
❑
❑
# Does the Plan include a Stormwater Facility Inspection Program?
■
❑
❑
Cl
Has the Stormwater Pollution Prevention Plan been implemented?
■
❑
❑
❑
Comment:
Qualitative Monitoring
Yes
No
NA
NE
Has the facility conducted its Qualitative Monitoring semi-annually?
■
❑
❑
❑
Comment:
Analytical Monitoring
Yes No
NA
NE
Has the facility conducted its Analytical monitoring?
MOOO
# Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas?
❑ ❑
■
❑
Comment:
Permit and Outfalls
Yes No
NA
NE
# Is a copy of the Permit and the Certificate of Coverage available at the site?
■ ❑
❑
❑
# Were all outfalls observed during the inspection?
■ ❑
❑
❑
# If the facility has representative outfall status, is it properly documented by the Division?
❑ ❑
■
❑
# Has the facility evaluated all illicit (non stormwater) discharges?
■ ❑
❑
❑
Comment:
Page: 3
pF W A rF;Y ; l 1� Michael F. Easley, Governor
o
William G. Ross, Jr., Secretary
North Carolina Department of Environment and Natural Resources
[p Alan W. Klimek, P.E., Director
Division of Water Quality
March 13, 2007
Mr. Henry Boswell
Corporate Regulatory Manager
Resinall Corporation
Water Street
P.O. Box 195
Severn, NC 27877
Subject: Compliance Evaluation Inspection 3/l/2007
Stormwater Permit No. NCS000292
Resinall Corporation
Severn, NC
Northampton County
Dear Mr. Boswell:
On March 1, 2007 Ms. Kelly Johnson, Central Office, and Mr, MyrI Nisely of the Raleigh Regional Office
of the Division of Water Quality conducted a Stormwater Compliance Evaluation Inspection with your
assistance, along with that of Steve Blowe, Bill Lewis, and Paul Pearce. It was a pleasure meeting all of
you, and thanks for the help that was given. The permit expired March 31, 2005, and an application for
renewal was submitted to DWQ September 2004.
The plant was in compliance with the permit, and had anchored the program around a well -written and
updated Stormwater Pollution Prevention Plan. Please see the attached checklist noting the topics that were
covered during the inspection.
Annual analytical data gathered during the past permit cycle, submitted with the permit renewal, was
sparse. Two reasons were given: 1) 2004 was a dry year in which no flow could be sampled, and 2)
Resinall stopped sampling when the permit expired. If no flow occurs in the future, please submit a report
form marked "No Flow to Sample" so DWQ will know the sampling was not being ignored. The old
permit did not explicitly address what to do after the permit expired, but it is expected that a facility will.
continue to operate under the conditions and responsibilities of the old permit until a new one is issued.
These instructions will be more clearly worded in future permits. See CFR40,§ 122.6 Continuation of
expiring permits. (a) EPA permits. When EPA is the permit -issuing authority, the conditions of an expired
permit continue in force under 5 U.S.C. 558(c) until the effective date of a new permit.
If you have any comments or questions, please contact me at 919-791-4200.
Sincerely,,
Myrl A. Nisely
cc: Kelly Johnson, Stonnwater Permitting Unit
RRO/SWP files Ofic
Water Quality Central Files North Carolina
NatumllJ
North Carolina Division of Water Quality Raleigh Regional Office Surface Water Protection Phone (919) 79t-4200 Customer Service
Internet: www.ncwalerquai1y.9M 1628 Mail Service Center Raleigh, NC 27699-1628 FAX (919) 788-7159 1-877-623-6748
An Equal Opportunity/Affirmative Action Employer— 50°% Recycled/10% Post Consumer Paper
Questions for SW Permit Inspections
Date: 03/01/2007 Permit No. NCS000292 Facility: Resinall Corporation
Time In: 10:00 AM Departure Time: Noon Inspector(s): Myrl Nisely,
Kelly
Johnson
YES
NO
NA
NE
1.
Is a copy of the Permit and the Certificate of Coverage available at the site?
®
❑
❑
❑
2.
Does the Plan include a General Location (USGS) map?
®
❑
❑
❑
3.
Does the Plan include a "Narrative Description of Practices"?
®
❑
❑
❑
4.
Does the Plan include a detailed site map including outfall locations?
®
❑
❑
❑
5.
Does the Plan include a list of significant spills in the past 3 years?
®
❑
❑
❑
6.
Has the facility evaluated all illicit (non stormwater) discharges to the storm sewer system?®
❑
❑
❑
7.
Has the facility evaluated feasible alternatives to current practices?
®
❑
❑
❑
8.
Does the facility provide all necessary secondary containment?
®
❑
❑
❑
9.
Does the Plan include a BMP summary?
®
❑
❑
❑
10.
Does the Plan include a Spill Prevention and Response Plan (SPRP)?
®'
❑
❑
❑
11.
Does the Plan include a Preventative Maintenance and Good Housekeeping Plan?.
®
❑
❑
❑
12.
Does the facility provide and document Employee Training?
®
❑
❑
❑
13.
Does the Plan include a list of Responsible Party(s)?
®
❑
❑
❑
14.
Is the Plan reviewed and/or updated annually?
®
❑
❑
❑
15.
Does the Plan include a Stormwater Facility Inspection Program?
®
❑
❑
❑
16.
Has the Plan been implemented?
®
❑
❑
❑
17.
Has the facility conducted its Qualitative Monitoring semi-annually?
®
❑
❑
❑
18.
Has the facility conducted its Quantitative (Analytical) monitoring?
❑
®
❑
❑
19. Does the facility have Vehicle Maintenance activities on site (uses more than
55 gallons of new motor oil per month)?
❑
❑
®
❑
19a. Has the facility conducted its Annual Quantitative (Analytical) monitoring at outfalls
receiving runoff from Vehicle Maintenance areas?
❑
❑
®
❑
20. Were all outfalls observed during the inspection?
®
❑
❑
❑
21. If the facility has representative outfall status, is it properly documented by the Division?
❑
❑
®
❑
Comments:
Recommendations:
Requirements:
o�0F W A r�9Q�
- 0 Michael F. Easley, Governor
Wiiliam G. Ross Jr., Secretary
rNorth
Carolina Department of Environment and Natural Resources
7 y
0
Alan W. Klimek, P.E. Director
Division of Water Quality
'ys^
December 3, 2004 •�
Henry G. Boswell
Resinall Corp.
PO Box 195
Severn, NC 27877
�r i
Subject: NPDES Permit Renewal Application LP �
+�
Permit Number NCS000292 •.
Individual Stormwater Permit .�,'
Northampton County / `
Dear Mr. Boswell:
The Division of Water Quality's Stormwater and
General Permits Unit hereby acknowledges receipt of your renewal
application for coverage under NPDES Permit Number NCS000292 on September 30, 2004. The submitted renewal package
contained the following items:
➢ Signed application
➢ Site map
➢ Analytical monitoring results summary
➢ Visual monitoring results summary
➢ Best Management Practices summary
➢ Narrative describing significant changes at the permitted facility
➢ Signed Stormwater Pollution Prevention Plan certification
A preliminary review of the submitted renewal application package has been conducted, and it appears to be complete. No
further information is required at this time. If you have any questions about the renewal process or would like to discuss this
letter, please contact me at (919) 733-5083, extension 537.
Sincerely,
A
nathan A. Diggs
Environmental Engineer
CC'. Raleigh Regional Office
Stormwater Permitting Unit
Central Files
twtCarolina
ra!!y
North Carolina Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 Phone (919) 733-7015 Customer Service
Internet h2o.enr.state.ne.us 512 N, Salisbury St. Raleigh, NC 27604 FAX (919) 733-2496 1-877-623-6748
An Equal OpportunitylAKrmatNe Action Empbyer -50% Recycled110% Post Consumer Paper