Loading...
HomeMy WebLinkAboutNCS000041_App attach 2_20140402Drainage OUTFALL NO. 1 0 HF aRD0L L B D L -- PI PL EO/PO - RAILCAR LOADING AREA e9e OUTFACE I NO. 2 d �Fn VALVE i IBOX VALVE .BOX \sd PS — PS PS J ` 'o - HAZARDC WASTE C RI nr, fin flRAGE C NpT q � o T tip TM� Stofe q hos 6 3 PP7 w > Ili® U U B Cr) Z XSt q o 0 hed Ao�rPd R wote � rS l/ F R �.40;9� o9e NORM WATER 1ETE(vTI1N POND (24,000GALLONS sso s - STORM WATER d RETENTION WALL y a (47,500 GALLONS) OUTFALL r* .. d o`� . NO. 4 °r0 O ppTT C SOD 7 so q ate. OUTFALL NO. 5 OUTFALL NO. 6 o 0 CONCRETE RETENTION POND I CONCRETE EO DILUTION D m TANK ° COOLING TOWERS 1 PHIS DRAWING IS THE PROPERTY OF AND CONTAINS CONFIDENTIAL 'ROPRIETARY INFORMATION BELONGING TO CIARIANT CORPORA T MUST BE RETURNED IMMEDIATELY AFTER COMPLETION OF USE OR 2EOUEST AND MUST NOT BE COPIED IN WHOLE OR IN PART NOR NFORMATION SHOWN THEREON DISCLOSED TO THIRD PARTIES OR OTHEI JSED EXCEPT WITH SPECIFIC PERMISSION QF CIARIANT CORPORA DRAWING APPROVALS ENGINEERING ESHA PRODUCTION BLDG. 100 UTILITIES (ELECTRICAL DISTRIBUTION, NITROGEN, POTABLE AND PROCESS WATER) BLDG. 101 BOILER HOUSE BLDG. 103 MODULAR BLDG. BLDG. 136 YARD AREA BLDG. 147 STORES BLDG. 151 PLANT 1 BLDG. 153 PLANT 3 BLDG, 154 PLANT 4 BLDG. 155 PLANT 5 BLDG. 156 FIRE SYSTEMS BLDG, 158 SALVAGE YARD BLDG. 159 PILOT PLANT BLDG. 160 ANALYTICAL LAB BLDG. 162 WAREHOUSE BLDG. 163 WWTP BLDG. 171 MAINTENANCE SHOP BLDG. 172 MAINTENANCE FACILITY BLDG. 174 GUARD HOUSES & SECURITY SYSTEMS BLDG. 189 ADMINISTRATION BUILDING BLDG. 190 PLUTO PRODUCTION FACILITY DEMO'D BLDG. 192 PLUTO DISTILLATION COLUMN DEMO'D LEGEND STORJ4WER ssn — oVALVE BOX oMANHOLE ®CATCH BASIN ElPUMP wamag. ESTIMATED DRAINAGE AREA a6ou!wp OUTSIDE CONTAINER STORAGE HAUL ROADS L— ---� 6 1 DSG 103/05/121 TW I REVISED TO SHOW CONCRETE RETENTION POND AS BUILT 5 DSG 04/19/10 GI MODIFIED TO SHOW NEW REQUIREMENTS 4 DSG 04/06/09 GI ADDED OUTSIDE STORAGE AREAS 3 DSG 02/03/09 GI REVISED STORM DRAINS 2 DSG 06/12/08 GI REVISED OUTFALL NO. 006 1 DSG 12/18/07 GI REVISED PER PLANT 5 UPGRADE & GENERAL REVISIONS FNO DSG 02/22/06 GI ISSUED AS BUILT FOR RECORD BY DATE eoon Clt,o' DESCRIPTION OF REVISION "'Clariant Mt. Holly West Plant, 625 East Catawba Avenue, Mt. Holly, NC 28120 TITLE: SITE PLAN STORM WATER DRAINAGE SCALE: 1 64 =1 -0' CAD FILE NUMBER: 1000G003-6 BYI DATE I DRAWING NO. DRAWN DSG 9/29/05 AREA I I DISC, SERIAL SHEET REV D GI 10/7/05 100 UG — OOU 6 APP' APP'VD G 1O/07/O5 1 - —OF— C:\AcadDrawings\dvtdm directory\100 - Utilities\General and Site\UG\1000G003-6.dwg, 3/13/201411:01:41 AM