HomeMy WebLinkAbout20190276 Ver 1_401 Application_20190301CLearWaLer $_PA10 C1earWater Environmental Consultants, Inc. www.cwenv corn February 28, 2019 Karen Higgins NC DEQ, Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 RE: High Hampton Dam Maintenance Nationwide Permit 3 Application Buncombe County, North Carolina Ms. Higgins: 2 0 1 90 2 76 The attached Pre -Construction Notification (PCN) is being submitted on behalf of property owners High Hampton Resort LLC. The project site is located on 3 Sheep Laurel Road, Cashiers, NC 28707. The applicant is seeking a Nationwide Permit 3 for the repair maintenance of three existing dams on High Hampton Lake, Jewel Lake, and McConnell Lake and the repair and replacement of an existing water intake irrigation structure. Should you have any questions regarding the attached PCN and supplemental information please do not hesitate to contact me at 828-698-9800. A copy of this application has been sent to Mr. David Brown of the US Army Corps of Engineers, Ms. Andrea Leslie of the NC Wildlife Resources Commission and Byron Hamstead of the US Fish and Wildlife Service for review. A courtesy copy of this application has also been sent to Kevin Mitchell at the NC Division of Water Resources Asheville Regional Office. Respectfully, Anna Priest, P.W.S. Environmental Scientist Copy Furnished: US Army Corps of Engineers — David Brown NC Wildlife Resources Commission — Andrea Leslie US Fish and Wildlife — Byron Hamstead NC Division of Water Resources — Kevin Mitchell 32 Clayton Street Asheville, NC 28801 828-698-9800 Tel i W R. Clent Riddle, P. S. Principal C�e�r�/ater Department of the Army Wilmington District, Corps of Engineers Attn: Scott McLendon, Chief Regulatory Division PO Box 1890 Wilmington, NC 28402-1890 -and- NC DWR, Webscape Unit Attn: Karen Higgins 512 North Salisbury Street Raleigh, North Carolina 27604 I, the current landowner/managing partner of the property identified below, hereby authorize C1earWater Environmental Consultants, Inc. (CEC) to act on my behalf as my agent during the processing of jurisdictional determination requests and permits to impact Wetlands and Water of the US subject to Federal jurisdiction under Section 404 of the Clean Water Act and/or Section 10 of the Rivers and Harbors Act of 1899. CEC is authorized to provide supplemental information as needed at the request of the USACE or DWR. Additionally, I authorize representatives of the Wilmington District, US Army Corps of Engineers to enter upon the property herein described for the purposes of conducting onsite investigations and issuing a determination associated with Wetlands and Waters of the US subject to Federal jurisdiction under Section 404 of the Clean Water Act and/or Section 10 of the Rivers and Harbors Act of 1899. Property Owner of Record: Property Owner Address: Phone Number: Email address: Daniel Communities on Behalf of Arlington Family Offices 3115 Timberlake Road, Suite 100 Vestavia, AL 35243 Cell (828) 506-0880 oschultz@danielcommunities.com Property Location: Cashiers, NC 28717SOOZ Owner/Managing partner Signature: Owner printed name: Date: Owen Schultz February 5th, 2019 32 Clayton Street Asheville, NC 28801 Phone: 828-698-9800 www.cwenv.com Preliminary ORM Data Entry Fields for New Actions SAW — 201 - BEGIN DATE [Received Date]: Prepare file folder ❑ Assign Action ID Number in ORM ❑ 1. Project Name [PCN Form A2a]: High Hampton Dam Maintenance 2. Work Type: Private 7 Institutional ❑ Government ❑ Commercial 3. Project Description / Purpose [PCN Form 63d and Be]: The purpose of the proposed project is to conduct dam maintenance work and replace water intake structure for irrigation purposes. 4. Property Owner / Applicant [PCN Form A3 or A4]: High Hampton Resort LLC 5. Agent / Consultant [PCN Form A5 — or ORM Consultant ID Number]: 3 6. Related Action ID Number(s) [PCN Form 135b]: 7. Project Location - Coordinates, Street Address, and/or Location Description [PCN Form Bib]: 35.097222, -83.082222, 3 Sheep Laurel Rd, Cashiers, NC 28707 8. Project Location -Tax Parcel ID [PCN Form 61a]: 7571-96-2365 and 7581-28-1691 9. Project Location — County [PCN Form A2b]: Jackson 10. Project Location — Nearest Municipality or Town [PCN Form A2c]: Cashiers 11. Project Information — Nearest Waterbody [PCN Form 62a]: Fowler Creek / Hampton Lake 12. Watershed / 8 -Digit Hydrologic Unit Code [PCN Form 62c]: Chatooga River 03060102 Authorization: Section 10 ❑ Section 404 ❑ Section 10 & 404 ❑ Regulatory Action Type: Standard Permit ✓ Nationwide Permit # 3 Regional General Permit # Jurisdictional Determination Request Pre -Application Request Unauthorized Activity Compliance ❑✓ No Permit Required Revised 20150602 Jackson County, NC ' I 92 � 'z 0,bi r a. r ... .. .- $iM¢Nonh CardmB DOT, EM, IEHE, Grmm, INCHEMENTP, NGA USr,'. *WARNING: HI NOTA SURVEY!* This map �L is prepared for inventory of real property within Jackson County. It is compiled from recorded >y deeds, plats, and public data records. Users of this map are hereby notified that the aforementioned public information sources should be consulted for verification. Jackson County or any County representative assumes no legal -esponsibility for the contents of this map. c `e )wner 1: HIGH HAMPTON RESORT LLC )wner 2: 'hysical Address: 3 SHEEP LAUREL RD 'roperty Description: HIGH HAMPTON RESORT kccount Number: 179292 'IN: 7571-96-2365 flailing Addressl: DANIEL COMMUNITIES CONTROLLER flailing Address2: 3104 BLUE LAKE DR STE 200 ;ity State: BIRMINGHAM AL :ip Code: 35243 )eed Reference: 2191/1486 )eed Date: 2017-06-30 00:00:00.0 ;ales Price: $11,650,000.00 kssessed Acreage: 219.52 flap Sheet: 7571.02 lat Reference: 22/123-136 ire District: CASHIERS 5 MI kppraisal Neighborhood: HIGH HAMPTON Jeighborhood Code: 07033 ownship: CASHIERS ownship Code: 07 otal Building Value: $2,499,240.00 and Value: $2,107,390.00 'otal Value: $4,606,630.00 DetailedJackson County, NC Tax Parcels Report •�� lsA�' �+.Ni •. �.�, , �. '`^'.mit. y.� sem- .ria ��!;r..•'r+i".i ,". Sci� ,lZf� . /R� _�. � 1►s�ii��ri r1ii.L Thursday, February 28, 2019 L('t \ ..-� -i vim" rern�r i , .. '•� 13 irw'< q j MGW6 1 -.4 31m State of North Carolina DOT, Esri. HERE renin, BJCREMENTP, NGA USGS 1 WARNING: THIS IS NOT A SURVEY!* This map is prepared for inventory of real property 4' within Jackson County. It is compiled from recorded deeds, plats, and public data records. Users of this map are hereby notified that the aforementioned public information sources should be consulted for verification. Ab �`. Jackson County or any County representative `h;`��;;�a' assumes no legal responsibility for the contents of this map. Owner 1: HIGH HAMPTON LAND LLC Owner 2: Physical Address: 3 SHEEP LAUREL RD Property Description: HIGH HAMPTON Account Number: 179371 PIN: 7581-28-1691 Mailing Addressl: DANIEL COMMUNITIES CONTROLLER Mailing Address2: 3104 BLUE LAKE DR STE 200 City State: BIRMINGHAM AL Zip Code: 35243 Deed Reference: 2191/1498 Deed Date: 2017-06-30 00:00:00.0 Sales Price: $12,156,500.00 Assessed Acreage: 703.22 Map Sheet: 7581.01 Plat Reference: 22/124-136 Fire District: CASHIERS 5 MI Appraisal Neighborhood: HIGH HAMPTON Neighborhood Code: 07033 Township: CASHIERS Township Code: 07 Total Building Value: $0.00 Land Value: $1,664,180.00 Total Value: $1,664,180.00 Office Use Only: Corps action ID no. DWQ project no. Form Version 1.4 January 2009 Pre -Construction Notification (PCN) Form A. Applicant Information 1. Processing 1 a. Type(s) of approval sought from the Corps: ❑ Section 404 Permit ❑ Section 10 Permit 1 b. Specify Nationwide Permit (NWP) number: 3 or General Permit (GP) number: 1c. Has the NWP or GP number been verified by the Corps? ❑ Yes ❑X No 1 d. Type(s) of approval sought from the DWQ (check all that apply): X❑ 401 Water Quality Certification — Regular ❑ Non -404 Jurisdictional General Permit ❑ 401 Water Quality Certification — Express ❑ Riparian Buffer Authorization le. Is this notification solely for the record because written approval is not required? For the record only for DWQ 401 Certification: ❑ Yes Q No For the record only for Corps Permit: Q Yes ❑ No 1f. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? If so, attach the acceptance letter from mitigation bank or in -lieu fee program. ❑ Yes ❑X No 1 g. Is the project located in any of NC's twenty coastal counties. If yes, answer 1 h below. ❑ Yes Q No 1 h. Is the project located within a NC DCM Area of Environmental Concern (AEC)? ❑ Yes Q No 2. Project Information 2a. Name of project: High Hampton Dam Maintenance and Water Intake Structure 2b. County: Jackson 2c. Nearest municipality / town: Cashiers 2d. Subdivision name: High Hampton 2e. NCDOT only, T.I.P. or state project no: n/a 3. Owner Information 3a. Name(s) on Recorded Deed: High Hampton Resort LLC 3b. Deed Book and Page No. 2191/1486 3c. Responsible Party (for LLC if applicable): n/a 3d. Street address: 3 Sheep Laurel Rd 3e. City, state, zip: Cashiers, NC 28707 3f. Telephone no.: 828-743-2411 3g. Fax no.: n/a 3h. Email address: n/a Page 1 of 10 PCN Form — Version 1.4 January 2009 4. Applicant Information (if different from owner) 4a. Applicant is: Q Agent ❑ Other, specify: 4b. Name: 4c. Business name (if applicable): 4d. Street address: 4e. City, state, zip: 4f. Telephone no.: 4g. Fax no.: 4h. Email address: 5. Agent/Consultant Information (if applicable) 5a. Name: Ms. Anna Priest 5b. Business name (if applicable): Clearwater Environmental Consultants, Inc. 5c. Street address: 32 Clayton St 5d. City, state, zip: Asheville, NC 28801 5e. Telephone no.: 828-698-9800 5f. Fax no.: n/a 5g. Email address: anna@cwenv.com Page 2 of 10 B. Project Information and Prior Project History 1. Property Identification 1a. Property identification no. (tax PIN or parcel ID): 7571-96-2365 1 b. Site coordinates (in decimal degrees): Latitude: 35.097222 Longitude: -83.082222 1c. Property size: 219.52 acres 2. Surface Waters 2a. Name of nearest body of water to proposed project: Fowler Creek/ Hampton Lake 2b. Water Quality Classification of nearest receiving water: B; Tr:+ 2c. River basin: Chattooga River 03060102 3. Project Description 3a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application: High Hampton 18 -hole golf course opened in 1928 and has three separate dammed lakes on the property. High Hampton Lake is used for irrigation as well as recreation. The surrounding land use consists primarily of the residential and commercial developments surrounding the High Hampton community. 3b. List the total estimated acreage of all existing wetlands on the property: 27.57 3c. List the total estimated linear feet of all existing streams (intermittent and perennial) on the property: 37,265 3d. Explain the purpose of the proposed project: See Supplemental information. 3e. Describe the overall project in detail, including the type of equipment to be used: See supplemental information. 4. Jurisdictional Determinations 4a. Have jurisdictional wetland or stream determinations by the Corps or State been requested or obtained for this property / project (includingall prior phases)in the past? ❑ Yes ❑X No ❑ Unknown Comments: 4b. If the Corps made the jurisdictional determination, what type of determination was made? ❑ Preliminary ❑ Final 4c. If yes, who delineated the jurisdictional areas? Name (if known): Agency/Consultant Company: Other: 4d. If yes, list the dates of the Corps jurisdictional determinations or State determinations and attach documentation. 5. Project History 5a. Have permits or certifications been requested or obtained for this project (including all prior phases) in the past? ❑X Yes ❑ No ❑ Unknown 5b. If yes, explain in detail according to "help file" instructions. See supplemental information. 6. Future Project Plans 6a. Is this a phased project? ❑ Yes ❑X No 6b. If yes, explain. Page 3 of 10 PCN Form — Version 1.4 January 2009 C. Proposed Impacts Inventory 1. Impacts Summary 1 a. Which sections were completed below for your project (check all that apply): ❑ Wetlands ❑X Streams — tributaries ❑ Buffers Q Open Waters ❑ Pond Construction 2. Wetland Impacts If there are wetland impacts proposed on the site, then complete this question for each wetland area impacted. 2a. Wetland impact number Permanent (P) or Temporary T 2b. Type of impact 2c. Type of wetland 2d. Forested 2e. Type of jurisdiction Corps (404,10) or DWQ (401, other) 2f. Area of impact (acres) W1 - Choose one Choose one Yes/No - VV2 - Choose one Choose one Yes/No VV3 - Choose one Choose one Yes/No VV4 - Choose one Choose one Yes/No W5 - Choose one Choose one Yes/No W6 - Choose one Choose one Yes/No - 2g. Total Wetland Impacts: 2h. Comments: 3. Stream Impacts If there are perennial or intermittent stream impacts (including temporary impacts) proposed on the site, then complete this question for all stream sites impacted. 3a. Stream impact number Permanent (P) or Temporary (T) 3b. Type of impact 3c. Stream name 3d. Perennial (PER) or intermittent (INT)? 3e. Type of jurisdiction 3f. Average stream width (feet) 3g. Impact length (linear feet) S1 T Fill Fowler Creek PER DWQ 35 30 S2 T Fill Fowler Creek PER DWQ 30 30 S3 T Fill UT PER DWQ 20 30 S4 - Choose one S5 Choose one - - S6 Choose one - 3h. Total stream and tributary impacts 90 3i. Comments: S1 - High Hampton Lake. S2 - Jewel Lake. S3 - McConnell Lake. S1 - S3. Temporary gravel pads may be installed in and around the stream immediately downstream of all three dams to aid in stabilization of temporary scaffolding for concrete work on dam walls. Page 4 of 10 PCN Form —Version 1.4 January 2009 4. Open Water Impacts If there are proposed impacts to lakes, ponds, estuaries, tributaries, sounds, the Atlantic Ocean, or any other open water of the U.S. then indivi ually list all open water impacts below. 4a. Open water impact number Permanent (P) or Temporary T 4b. Name of waterbody (if applicable) 4c. Type of impact 4d. Waterbody type 4e. Area of impact (acres) 01 P High Hampton Lake Dredging Lake 0.01 02 T High Hampton Lake Other Lake 0.03 03 P High Hampton Lake Other Lake 0.01 04 - Choose one Choose 4f. Total open water impacts 0.05 4g. Comments: "'gn Hampton iaKe will a drawn down ana aredgedol collected sediment ma ena o allow Tor valve repairs. 02 - Dredging equipment will require a temporary access road. 03 - A water intake structure will be maintained and replaced for irrigation. 5. Pond or Lake Construction If pond or lake construction proposed, the complete the chart below. 5a. Pond ID number 5b. Proposed use or purpose of pond 5c. 5d. 5e. Wetland Impacts (acres) Stream Impacts (feet) Upland (acres) Flooded Filled Excavated Flooded Filled Excavated P1 Choose one P2 Choose one 5f. Total: 5g. Comments: 5h. Is a dam high hazard permit required? ❑ Yes ❑ No If yes, permit ID no: 5i. Expected pond surface area (acres): 5j. Size of pond watershed (acres): 5k. Method of construction: 6. Buffer Impacts (for DWQ) If project will impact a protected riparian buffer, then complete the chart below. If yes, then individually list all buffer impacts below. If any impacts require mitigation, then you MUST fill out Section D of this form. 6a. Project is in which protected basin? ❑ Neuse ❑ Tar -Pamlico ❑ Catawba ❑ Randleman ❑ Other: 6b. Buffer Impact number - Permanent (P) or Temporary T 6c. Reason for impact 6d. Stream name 6e. Buffer mitigation required? 6f. Zone 1 impact (square feet) 6g. Zone 2 impact (square feet 61 Yes/No B2 Yes/No B3 - Yes/No B4 - Yes/No B5 - Yes/No B6 - Yes/No 6h. Total Buffer Impacts: 6i. Comments: Page 5 of 10 D. Impact Justification and Mitigation 1. Avoidance and Minimization 1a. Specifically describe measures taken to avoid or minimize the proposed impacts in designing project. In order to maintain proper dam requirements, repairs are necessary for all three dam at the High Hampton property. In order to minimize impacts, the project was designed to utilize spot repairs where necessary, instead of a full dam replacement or entire wall repair. The water intake structure replacement was designed to have minimal impacts on High Hampton Lake by utilizing an irrigation company who specializes in intake structures built with lasting and appropriately sized components. 1 b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques. For the concrete work, scaffolding with a minimal footprint will be utilized to conduct the repairs. Any gravel pads installed to assist with the stabilization of the scaffolding will be temporary and removed once the work is complete. The site will be returned to the original condition. For the lake dredging work, a track -hoe will be utilized for removing sediment accumulated. The machine will require access into the lake bed and will minimize disturbance by utilizing only one access route. Please refer to Appendix A for more information. 2. Compensatory Mitigation for Impacts to Waters of the U.S. or Waters of the State 2a. Does the project require Compensatory Mitigation for impacts to Waters of the U.S. or Waters of the State? ❑ Yes ❑X No 2b. If yes, mitigation is required by (check all that apply): ❑ DWQ ❑ Corps 2c. If yes, which mitigation option will be used for this project? ❑ Mitigation bank ❑ Payment to in -lieu fee program ❑ Permittee Responsible Mitigation 3. Complete if Using a Mitigation Bank 3a. Name of Mitigation Bank: 3b. Credits Purchased (attach receipt and letter) Type: Choose one Type: Choose one Type: Choose one Quantity: Quantity: Quantity: 3c. Comments: 4. Complete if Making a Payment to In -lieu Fee Program 4a. Approval letter from in -lieu fee program is attached. ❑ Yes 4b. Stream mitigation requested: linear feet 4c. If using stream mitigation, stream temperature: Choose one 4d. Buffer mitigation requested (DWQ only): square feet 4e. Riparian wetland mitigation requested: acres 4f. Non -riparian wetland mitigation requested: acres 4g. Coastal (tidal) wetland mitigation requested: acres 4h. Comments: 5. Complete if Using a Permittee Responsible Mitigation Plan 5a. If using a permittee responsible mitigation plan, provide a description of the proposed mitigation plan. Page 6 of 10 PCN Form — Version 1.4 January 2009 6. Buffer Mitigation (State Regulated Riparian Buffer Rules) — required by DWQ 6a. Will the project result in an impact within a protected riparian buffer that requires buffer mitigation? Yes No 6b. If yes, then identify the square feet of impact to each zone of the riparian buffer that requires mitigation. Calculate the amount of mitigation required. Zone 6c. Reason for impact 6d. Total impact (square feet) Multiplier 6e. Required mitigation (square feet) Zone 1 3 (2 for Catawba) Zone 2 1.5 6f. Total buffer mitigation required: 6g. If buffer mitigation is required, discuss what type of mitigation is proposed (e.g., payment to private mitigation bank, permittee responsible riparian buffer restoration, payment into an approved in -lieu fee fund). 6h. Comments: Page 7 of 10 E. Stormwater Management and Diffuse Flow Plan (required by DWQ) 1. Diffuse Flow Plan 1 a. Does the project include or is it adjacent to protected riparian buffers identified ❑ Yes ❑X No within one of the NC Riparian Buffer Protection Rules? 1 b. If yes, then is a diffuse flow plan included? If no, explain why. ❑ Yes ❑ No 2. Stormwater Management Plan 2a. What is the overall percent imperviousness of this project? 0.001% 2b. Does this project require a Stormwater Management Plan? ❑ Yes ❑X No 2c. If this project DOES NOT require a Stormwater Management Plan, explain why: The project will not require less than 24% imperviousness to the area. 2d. If this project DOES require a Stormwater Management Plan, then provide a brief, narrative description of the plan: 2e. Who will be responsible for the review of the Stormwater Management Plan? 3. Certified Local Government Stormwater Review 3a. In which localgovernment's jurisdiction is thisproject? ❑ Phase II 3b. Which of the following locally -implemented stormwater management programs ❑ NSW ❑ USMP apply (check all that apply): ❑ Water Supply Watershed ❑ Other: 3c. Has the approved Stormwater Management Plan with proof of approval been ❑ Yes ❑ No attached? 4. DWQ Stormwater Program Review ❑Coastal counties ❑ HQW 4a. Which of the following state -implemented stormwater management programs apply ❑ORW (check all that apply): ❑Session Law 2006-246 ❑Other: 4b. Has the approved Stormwater Management Plan with proof of approval been ❑ Yes ❑X No attached. 5. DWQ 401 Unit Stormwater Review 5a. Does the Stormwater Management Plan meet the appropriate requirements? ❑ Yes ❑ No 5b. Have all of the 401 Unit submittal requirements been met? ❑ Yes ❑ No Page 8 of 10 PCN Form — Version 1.4 January 2009 F. Supplementary Information 1. Environmental Documentation (DWQ Requirement) 1a. Does the project involve an expenditure of public (federal/state/local) funds or the ❑ Yes Q No use of public (federal/state) land? 1 b. If you answered "yes" to the above, does the project require preparation of an environmental document pursuant to the requirements of the National or State ❑ Yes ❑ No (North Carolina) Environmental Policy Act (NEPA/SEPA)? 1c. If you answered "yes" to the above, has the document review been finalized by the State Clearing House? (If so, attach a copy of the NEPA or SEPA final approval letter.) ❑ Yes ❑ No Comments: 2. Violations (DWQ Requirement) 2a. Is the site in violation of DWQ Wetland Rules (15A NCAC 2H .0500), Isolated Wetland Rules (15A NCAC 2H .1300), DWQ Surface Water or Wetland Standards, ❑X Yes Q No or Riparian Buffer Rules (15A NCAC 2B .0200)? 2b. Is this an after-the-fact permit application? ❑Yes Q No 2c. If you answered "yes" to one or both of the above questions, provide an explanation of the violation(s): High Hampton Country Club was issued a notice of violation on January 7, 2019 (NOV-2018-SS-0052) for unauthorized stream and wetland impacts in an area unrelated to the project currently being applied for in this Pre-Construction Notification. The NOV is being addressed with an simultaneous NWP 27 that is being applied for after-the-fact and reapplication of the Individual Permit. 3. Cumulative Impacts (DWQ Requirement) 3a. Will this project (based on past and reasonably anticipated future impacts) result in ❑ Yes Q No additional development, which could impact nearby downstream water quality? 3b. If you answered "yes" to the above, submit a qualitative or quantitative cumulative impact analysis in accordance with the most recent DWQ policy. If you answered "no," provide a short narrative description. 4. Sewage Disposal (DWQ Requirement) 4a. Clearly detail the ultimate treatment methods and disposition (non-discharge or discharge) of wastewater generated from the proposed project or available capacity of the subject facility. No waste water is generated from this project. Page 9 of 10 PCN Form — Version 1.4 January 2009 5. Endangered Species and Designated Critical Habitat (Corps Requirement) 5a. Will this project occur in or near an area with federally protected species or YesX No ❑ ❑ habitat? 5b. Have you checked with the USFWS concerning Endangered Species Act ❑ Yes ❑X No impacts? 5c. If yes, indicate the USFWS Field Office you have contacted. - 5d. What data sources did you use to determine whether your site would impact Endangered Species or Designated Critical Habitat? FWS county data and Natural Heritage Program GIS data. Additionally, CEC consulted the FWS's "Northern Long -Eared Bat Consultation Areas" map for Jackson County. The project is not located within an area with any known occurrences of hibernation or maternity sites. 6. Essential Fish Habitat (Corps Requirement) 6a. Will this project occur in or near an area designated as essential fish habitat? ❑ Yes Q No 6b. What data sources did you use to determine whether your site would impact Essential Fish Habitat? South Atlantic Habitat and Ecosystem IMS. Impact will not occur in a marine system. 7. Historic or Prehistoric Cultural Resources (Corps Requirement) 7a. Will this project occur in or near an area that the state, federal or tribal governments have designated as having historic or cultural preservation Yes ❑ No status (e.g., National Historic Trust designation or properties significant in North Carolina history and archaeology)? 7b. What data sources did you use to determine whether your site would impact historic or archeological resources? National Register of Historic Places records maintained by the NC State Historic Preservation Office (SHPO). It is the opinion of CEC, that the proposed repair and maintenance project is not likely to threaten the integrity of nearby historically regulated sites. 8. Flood Zone Designation (Corps Requirement) 8a. Will this project occur in a FEMA -designated 100 -year floodplain? ❑ Yes Q No 8b. If yes, explain how project meets FEMA requirements: 8c. What source(s) did you use to make the floodplain determination? NC Floodplain Mapping Program. Map panel 3700757100J (effective April 19, 2010). cleweet R,&. Applicant/Agent's Signature Applicant/Agent's Printed Name Date (Agent's signature is valid only if an authorization letter from the applicant isprovided.) Page 10 of 10 V, High Hampton Dam Maintenance �.Pill 64, ■!. Cashiers Cashiers'p -^-- - o — fake Rd Is 0 W High Hampton Property Boundary ------------- McConnell Lake 1� 40 � r .3mp to \ Ana \% COUn t ,, \ Iub Turk esti\, ---------------- ,- tient 7rc Dr a Legend High Hampton Property Boundary Drawn by: KAY 2.27 19: CEC Project# 918 Jackson County, North Carolina T' - c e I A, % I I _J I i Wal High Hampton Lake Hampton Jewel Lake ODr Headwatell "Ai Golf Club N 0 0.25 0.5 1 Miles ,,�earWater 32 Clayton Street Asheville, North Carolina 28801 Site Vicinity Map Figure 1 High Hampton Dam Maintenance ti High Hampton �• Property Boundary t i 1 • L. RuC 1. -Mtn { {, • •`* McConnell Lake .-- 4.6 Mtn Ula 1 High Hampton Lake- 4n Gap ! r �-In er, --=--«;.._—;---,��, ` i ;�,.�,�; �• Jewel Lake ,. - ,, Legend r 0 0.25 0.5 1 r� High Hampton Property Boundary`a- I----- � Miles Drawn by: KAY 2.27.19, GEC PF ' '18"--- `y Jackson County, CLear\Wer USGS Topographic Ma �'P North Carolina Cashiers Quad 32 Clayton Street Asheville, North Carolina 28801 Figure 2 High Hampton Dam Maintenance Jewel Lake Legend Access Road Gate Valve 0 50 100 200 Feet Drawn by: KAY 2.27.19, CEC Project# 918 Jackson County, CLearMter Impact Map North Carolina 32 Clayton Street Figure 3.0 Asheville, North Carolina 28801 it IT ,4 dl High Hampton•S.+ r CCC -L Property Boundary 14 W/ °,, •1111 > t t`i tHigh Hampton- AMv ` tl„�,y�yll� c 1�, fi 1 ti V.1 1 • �l SI, � � �.- ` L,� 111 1� i A I ' emW9, iLegend O ,r , 1,000 1// 4,000 As �. ,� _ �r � �, QQf � pry - F. . '�Y• �� _ Engineer Drawings CONCRETE DAM REPAIRS: HIGH HAMPTON LAKE, JEWEL LAKE & McCONNELL LAKE DAMS CASHIERS, NC STRUCTURAL NOTES An. GENERAL 1. THE PROVIDED DRAWINGS ARE LIMBED TO THE ITEMS SPECIFIED HEREIN NO OPINION IS OFFERED, AND NONE SHOULD BE INFERRED REGARDING OTTER ASPECTS OF THIS STRUCTURE, OR THE STRUCTURES TAKEN AS A WHOLE. PINY ASSOCIATED REMEDIES EXPRESSED OR REFERENCED ARE EXCLUSIVE TO THE ITEMS SPECIFIED HEREIN. NO WARRMTIY IS EXPRESSED OR IMPLIED. 2. THE DRAWINGS CONTAINED HEREIN, I -OLE OR I -ART, REMAIN THE PROPERTY OF MEDL= 8 ASSOCIATES ENGINEERING, PA THE DRAWINGS MAY NOT BE USED, TRANSFERED OR REPRODUCED FOR ANY PROJECT OTHER THAN THAT SPECIFIED WITHIN THE DRAWINGS WITHOUT WRITTEN CONSENT FROM MEDL= 6 ASSOCIATES ENGINEERING, PA 3. ALL WORK SHALL BE IN ACCORDANCE WITL THE CURRENT EDITION OF THE INTERNATIONAL BUILDING CODE, AS ADOPTED AND SUPPLEMENTED BY LOCAL REGULATIONS. 4. VERIFY ALL DIMENSIONS, ELEVATIONS AND SITE CONDITIONS PRIOR TO START OF CONSTRUCTION. 5. NOTIFY THE ENGINEER OF ANY DISCREPANCIES OR INCONSISTENCIES. 6. NO CHANGES TO THE INFORMATION SFOWM ON TLE DMWINGS OR SUBSTITUTIONS OF MATERIALS SHALL BE MADE WITHOUT THE SPECIFIC WRITTEN APPROVAL OF THE ENGINEER. 7. DESIGN INFORMATION SHOWN ON THE DRAWINGS PROVIDE OVERALL DIMENSIONAL PARAMETERS AND DESCRIBE ELEMENTS TO BE CONSTRUCTED. B. THE ENGINEER SHALL BE NOTIFIED OF ANY PROPOSED MODIFICATIONS. 9. DEMOLITION SHALL INCLUDE REMOVAL, TRANSPORT AND DISPOSAL OF ALL WASTE MATERIAL RELATED TO THE CONSTRUCTION OF THE PROJECT TO AN APPROVED FACILITY. 10. CONTRACTOR SMALL ATTEND PRE-BID CONFERENCE ON SITE TO REVIEW CUNDITOW W/ EOR. DATE TBD BY OWNER REPRESENTATIVE. 96. DESIGN LOADS HYDROSTAT[ LOADS: FLUIDPRESSUR............................................................................... 62 PCF WIND LOADS: BASIC WIND SPEED.......................................................................... 90 MPH 1. ALL STRUCTURAL ELEMENTS DESIGNED TO SUSTAIN SPECIFIED DESIGN LOADS IN COMBINATION SO AS TO PRODUCE THE MOST CRITICAL CONDITIONS. 2. WHERE CONFLICTS OCCUR BETWEEN NOTES OR DRAWINGS, THE CONTRACTOR SHALL NOT PROCEED WITH THE AFFECTED MORAL UNTIL THE STRUCTURAL ENGINEER ISSUES A CLARIFICATION. 3. THE STRUCTURAL CONTRACT DRAWINGS SHALL NOT BE USED AS TEMPLATES FOR SMDP DRAWINGS UNLESS EXPLICIT APPROVAL IS PROVIDED BY THE STRUCTURAL ENGINEER IN ADVANCE OF ANY SUBMTRALS. SUBMITTALS RECEIVED THAT HAVE USED THE DRAWINGS WITHOUT APPROVAL WILL BE REJECTED WITHOUT RENEW. © CONCRETE REPAIRS 1. WORK SHALL CONFORM TO THE LATEST EDITIONS OF ACI SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI MI) AND BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318). 2. CONCRETE REINFORCEMENT BARS SHALL CONFORM TO ASTM MI5, GRADE 60. REINFORCEMENT DESIG SPED AS CONTINUOUS SHALL IAP 57 BAR DIAMETER UNLESS NOTED ODERWISE. PROVIDE 3" MINIMUM CONCRETE COVER TO REINFORCEMENT WHEN CONCRETE IS PLACED AGAINST EA' H, 11/2" MINIMUM COVER ELSEWHERE UNLESS OTHERWISE NOTED. REINFORCEMENT NOT FULLY ENCASED BY CONCRETE SHA. BE EPDXY COATED. 3. PROPRIETARY REPAR PRODUCTS: CONTRACTOR SHa11 PROVIDE SUBMITTALS FOR ALL PRODUCTS SPECIFIED. SUBSTITUTIONS MUST BE APPROVED BY EOR PRIOR TO INSTALATON : A) REPAIR MORTARS: 1) SIKH 211 SCC PLUS 2) SIKA SIKACEM 133 (MACHINE -APPLIED ONLY) B) BONDING PRIMER/REINFORCEMENT CORROSION PROTECTION: 1) SIKH ARMATEC-110 EPOCEM Q ORAL% REPAIR SEALANT PASTE I) SIKH SI(ADUR 31 HI -MOD GEL D) CRAG REPAIR CHEMICAL UT GRO 1) SIXA SI(AFD( HH HYDROPHILIC 4. REPMRMORTARSSHAIIMEETTHEFOLLOWINGCONTENTANDSRFORMANCEREQUIREMEMIS: A) MINIMUM COMPRESSIVE STRENGTH (PA) AT 28 DAYS: 1) SIKH 211 FLUS: 6,000 P51 2) SIKA SI(ACEM 133: 7,500 PSI G) Wk RATIO: PER MANUFACTURER'S MIX SPECIFICATIONS H) MAXIMUM NOMINAL AGGREGATE SIZE: N/A 1) FIFE AGGREGATE: N/A 3)WATER: ASTM C-94 AND POTABLE K)SLUMP: N/A L)AIR ENTWMENT: WA M) CONTRALTOR SHALL REFER TO MIX SPECIFICATION PROVIDED BY MANUFACTURER TO VERIFY MIX CONTENT S. CONCRETE REPAIR PROCEDURE: A) SPATTED/DELAMINATED CONCRETE REPAIRS: 1) HAMMER SOUND SURFACE OF CONCRETE TO DETERMINE EXTENT OF DETERIORATION. MARK t3 INCHES BEYOND DETERIORATION TO DESIGNATE PERIMETER OF REPAIR AREA. TO EXTENT PRACTICAL, MAXIMIZE LENGTH OF CONTINUOUS STRAIGR LIFTS W/ MINIMAL NUMBER OF CORNERS WHEN MARKING PERIMETER. VERIFY EXTENT CK REPAIR AREA W/ EOR 2) SAWCUT 3/4INCH NFO CONCETE AT PERIMETER OF REPAIR AREA VERIFY DEPTH OF REINFORCING PRIOR TO SAWCUTTING. ADJUST DEPTH AS REQD TO AVOID DAMAGE TO REIWdRCNG. 3) CHIP AWAY RETE CONCTO SW W SUBSTRATE, MINIMUM DEPTH OF 2INCHESS, MAXIMUM DEPTH OF ONE-HALF DAM WALL THICKNESS. REMOVE 3/41NCH RADIALLY AROUND EXPOSED RENHMO-HELDFORCING, FIRST MAT ONLY. USE HO -HELD AMMO ROTARY HER, DEMRICN HAMMER, OR SIMILAR MEANS TO REMOVE CONCRETE. TAKE CARE TO AVOID DAMAGE TO REINFORCING 4) USE WIRE BRUSH TO REMOVE CORROSION FROM REINFORCING HIGH-PRESSURE WASH WITH CLEAN WATER AFTER MECHANICAL CLEANING 5) PREPARE SUBSTRATE FOR APPLICATION OF REPAIR MORTAR. REMOVE ALL DETERIORATED 0000PETE, DIRT, OIL, CREASE, AND ALL BOND-INHBITING MATERIALS FROM SURFACE. PROVIDE EXPOSED AGGREGATE SURFACE WITH A MINIMUM SURFACE PROFILE PER MANUFACTURER SPECIFICATIONS. SATURATE SURFACE WITH CLEAN WATER AND PROVIDE SATURATED SURFACE DRY (SSD) SURFACE WITH NO STANDING WATER DURING APPLICATION. 6) HAND APPLY BONDING AGSM/ANTI-CORROS[W COATING TO EXPOSED AND CLEWED REILiORCING 7)INSTALL REPAIR MORTAR MR MANUFACTURERS SPECIFICATIONS 8) MOIST MARE USING ABSORPTIVE COVER (PASHTO M 182 BURLAP) OR MOISTURE -RETAINING COVER (ASTM C ]]1 POLYETHYLENE FILM) PER ACI RECOMMENDATIONS FOR PORTLAND CEMENT. MOIST CURE FOR 7 DAYS MINIMUM PRIOR TO APPLICATION OF SEALANT PRODUCT. 9) AFTER REPAIR MORTAR HAS ADEQUATELY CURED, APPLY SEALANT PRODUCT PER MANUFACTURERS WRITTEN SPECIFICATION&: i) AT UPSTRFAWWATERUNE REPAIRS: SIMTOP SEAL -107 FLEXIBLE CEMENTTTWS WATERPROOFING SLURRY. APPLY 2 COATS W N RIUM TO 4INCES BEYOND PERIMETER OF REPAIR AREA EXTEND OVER TOP SURFACE OF DAM. AT DOVMSTREPM REPAIRS: SIXAGARD 705L PENETRATING SEALER. APPLY TO ENTIRE DOWN STREMM FACE OF DAM. DRAWING INDEX PAGE DESCRIPTION SO.1 COVER SHEET, DRAWING INDEX S1.1 CONCRETE REPAIR ELEVATIONS S2.1 CONCRETE REPAIR DETAILS CO EM REPAIRS (CONT'D) S. CONCRETE REPAIR PROCEDURE (CONTD) B) C3Aa REPAIRS: I) EXAMINE FACE OF DAM AND PHYSICALLY MARK CRACKS IN EXCESS OF 2D W LS IN WIDTH AND/OR THOSE W/ EFFLORESCENCE, EVIDENCE OF WATER SEEPAGE. RENEW EXTENT OF CRACKS DESIGNATED FOR REPAIR W/ EOR. 2) GIN OFF EFRORESCENKE ALONG DENGIH OF CRACK TO REVEAL CONKREIE SU85TRAlE 3)SEAL SURFACE OF CRACK WITH CRACK REPAIR SEALANT PASTE PER MANUFACTURER'S WRITTEN INSTRUCTIONS 4) DRILL 5/&INCH DIAMETER HOLES ALONG SIDE OF CRACK AT 45 DEGREE ANGLE. SPACE HOLES AT APPROXIMATELY 12 INCHES ON CENTER. RUSH DRILLED HOLES WITH WATER TO REMOVE DEBRIS AND DRILL DUST. INSTALL INJECTION PORTS. 5) INJECT PORT AT LOWEST HOLE (FOR VERTICAL CRACKS) OR FIRST RUSHED HOLE (FOR HORIZONTAL CRACKS). I WECT CHEMICAL GROUT PER MANUFACTURER'S WRITTEN INSTRUCTIONS. OONTINWE INJECTING UNTIL GROUT APPEARS AT ADJACENT HOLE. AFTER COMPLETING INJECTIONS AT 4 HOLES, RETURN TO FIRST HOLE AND REPEAT PROCESS. 6) CUT OFF 1 WECTION PORTS AND GRIND SEALANT PASTE RUSH WITH CONCRETE SUBSTRATE. C) COMBINED REPAIRS: 1) TO BE PERFORMED WHERE CRACK MEETING REPAIR CRITERIA PER (5XB)(1) PASSES THROUGH DETERIORATED CONCRETE DESIGNATED FOR REPAIR PER (5)(A)(I), OR WHERE SUCH CRACK IS REVEALED DURING PREPARATION OF SUBSTRATE PER (5)(A)(3). 2) PREPARE SUBSTRATE AND CLEAN REINFORCING PER (5)(A)(Ib) 3)INJECT CRACK MR (5)(B)(. ) 4) IN5TALL REPAIR MORTAR AND FINISH REPAIR AREA PER (5)(A)(74) G QUALITY ASSURANCE: A) INSTALLER QUALIFICATIONS: A QUALIFIED INSTALLER WHO EMPLOYS ON PROJECT PERSONNEL QUALIFIED AS ACI-MTLFED RATWORK TECHNICIAN AND FINISHER AND A SUPERVISOR WHO IS AN ACI -CERTIFIED CONCRETE FLAIWORK CIAN. a) SHOTCRETE INSTALLER QUALIFICATIONS: A QUALIFIED INSTALLER WHO EMPLOYS ON PROJECT PERSONNEL QUALIFIED AS ACI -CERTIFIED NOZZLEMAN AND A SUPERVISOR WHO IS AN ACIQERTIFIED NOZZUEMAI. Q TESTING AGENCY QUALIFICATIONS: AN INDEPENDENT AGENCY, ACCEPTABLE TO AUTHORITIES HAVING lURL50ICRON, QUALIFIED ACCORDING TO ASTM C 1077 AND ASTM E 329 FOR TESTING INDICATED, AS DOCUMENTED ACCORDING TO ASTM E 548. 7. FIELD QUALITY CONTROL: A) TESTING AND INSPECTING: ENGAGE A QUALIFIED TESTING AND INSPECTING AGENCY TO PERFORM TESTIS AND INSPECTIONS AND To SOW REOR PTS. B) CONCRETE TESTS: TESTING OF COMPOSITE SAMPLES OF FRESH CONCRETE OBTAINED ACCORDING TO ASTM C-172 SHALL BE PERFORMED ACCORDING TO THE FOLLOWING REQUIREMENTS: 1) FREQUENCY: ONE COMPOSITE SAMPLE FOR EACH DAYS PW R OF EACH MIX, PLUS ONE SET FOR EACH ADDITIONAL 25 M YD OR FRACTION THEREOF. 2) COMPRESSION TEST SPECIMENS: ASTM C-31. CAST AND LABORATORY CURE TWO SETS OF STANDARD CYLINDER SPECMENS FOR EACH COMPOSITE SAMPLE. 3) COMPRESSNE STRENGTH TESTS: ASTM C-39. TEST ONE SET O TWO UBDRATMY-RED SPECIMENS AT T DAYS AND ONE SET OF TWO SPECIMENS AT 28 DAYS. a) A COMPRESSIVE -STRENGTH TEST SHALL BE THE AVERAGE COMPRESSIVE STRENGTH FROM A SET OF TWO SPECIMENS OBTAINED FROM SAME COMPOSTS SAMPLE AND TESTED AT AGE INDICATED. 4) STRENGTH OF EACH CONCRETE MIXTURE WILL BE SATISFACTORY IF EVERY AVERAGE OF MY THREE CONSECUTIVE COMPFESSFESTRENGiH TESTS EQUALS OR EXCEEDS SPECIFIED COMP LVE STRENGTH AND NO COMPRESSIVE -STRENGTH TEST VALUE FALLS BELOW SPECIFIED COMPRESSIVE STRENGTH BY MORE THAN 500 PSI C) CRAG REPAIR MIS: CONTRACTOR SHALL PROVIDE 2-INOH X &INCL LONG CONCRETE CORES FROM CRACK REPAIRS TO EOR FOR RENEW 1) FREQUENCY: WE CORE SAMPLE FOR EVERY 25 LINEAR FEET OF COMPLETED CRAG REPAIRS 2) CORE SAMPLE SHALL DEMONSTRATE FULL PENETRATION OF REPAIR GROUT ALONG WIDTH AND DEPTH OF CRACK. D) ADDRIOWTL TESTING AND INSPECTING, AT CONTRACTOGS EXPENSE, WILL BE PERFORMED N DETERMINE COMPLIMXE OF REPLACED OR ADDITIONAL WORK -SPECIFIED REQUIREMENTS, AND TO CORRECT DEFICIENCIES IN THE WORK THAT TEST REPORTS AND INSPECTIOW INDICATE DOS NOT COMPLY WITH THE CONTRACT DOCUMENTS. B. REPAIR .UP A) CONTRACTOR SHALL PREPARE A MOCK-UP FOR EACH REPAIR TYPE PER (6)(A) AND (6)(5) FOR RENEW BY EOR AND REPAIR PRODUCT MANUFACTURERS REPRESENTATIVE. MOCK-UP FOR REPAIR TYPE (6)(C)15 NOT REQUIRED. MINIMUM REQUIREMENTS FOR MOCK-UPS OF EACH REPAIR TYPE: I) DETERIORATED CONCRETE, (6)(A): FINISHED REPAIR THROUGH STEP (6)(A)(7), MINIMUM 15 SF. IN -PROCESS REPAIR THROUGH STEP (6)(A)(5), MINIMUM 15 SF ADDITIONAL. 2) CRAG REPAIR (6)(B): FINISHED REPAIR THROUGH STEP (6)(B)(5), MINIMUM 10 LF. MOa4UP SHALL DEMONSTRATE IWECTION PROCESS. TYPICAL ABBREVIATIONS A.B. ADD'L ANCHOR BOLT ADDITIONAL H.D.G. H.S. ARC 'L ARCHITECTURAL NST. BM. BEAMJF. B.P. BASE PLATE LT. BRG BEARING HAS. SSMT. BASEMENT MAX. BTM. BTR. BOTTOM BETTER MECH. MANU C1. P. CAST IN PLACE MIN. C.1. CONTROL OR CONSTRUCTION JOINT NOM. CR. CLEAR N.T.S. CMU CONCRETE MASONRY UNIT OM. COL. COLUMN O.C. COW. COMPOSITE P.C. CON[ CONCRETE K. CONST. CONE. CONSTRUCTION CONTINUOUS PREFAB. P.T. COORD. COORDINATE REF. DET. DETAIL REINE. DIA DIAMETER SECT. DWG DRAWING SIM. EB. EXPANSION BOLT STD. E.0.5. EDGE OF SLAB SIL. EO. W. EDGE OF WALL STRUa. EQ. ELEV. EQUAL ELEVATION SQ. T.O.S. (E) EXISTING T.0 W. EW. EACH WAY TRANS. F.F. FINISHED ROOK TYP. FIN. FINISH(ED) U.O.N. RR 8000. V.If. RID. FTG. FOUNDATION FOOTING VERT. WOLM. GALV. GALVANIZED WT. H.C. HDRIZ. IKK10W CORE HORIZONTAL W.W.F. HOT DIP GALVANIZED HEADED STUD JOIST JOINT LICIT MASONRY MAXIMUM MECHANICAL MANUFACTURER MINIMUM NOMINAL NOT TO SCALE OPPOSITE HAND ON CENTER PRECAST OR PILE CAP PLATE PREFABRICATED PRESSURE TREATED REFERENCE REINFORCEMENT SECTION SIMILAR STANDARD STEEL STRUCTURAL SQUARE TOP OF SLAB / TOP CF STEEL TOP OF WALL TRANSVERSE TYPICAL UNLESS OTHERWISE NOTED VERIFY IN FIELD VERTICAL WOLMANIZED WEIGHT WELDED WIRE FABRIC DMI LOCATIONS HGH HAMPTON NICE DAM JEWEL VICE DAM MCOONNEIL LME DAM a Z W O Q J kn K W Z Lu z Lu ogW Lu Z a u z O O Q U = j O J Z = O LLJ V Q Q a LLJ +-I LTJ u zy, .^-H O F" Of d Z o m � O D_Ln i U F1� [a� DETERIORATED CONC. AT WATERLINE T/DPM E WATER LEVEL 3" n 1 5 -Ll DRAW LME TO LEVEL REQ'D TO REVEAL SAWCW 3/4" DEEP AROUND PERIMETER OF WLI EMEW OF DETERIORATED DOW. AT (E) CONC. DPM - REPAIR Al 3" 2 1-111-1 OF UPSTREPM FACE AND PROVIDE SUFFICEW DETERIORATED C O IO EXJEW PRACTICAL, CIFPRANCE FOR REPAIR WORK. COORDINATE MMIMRE LENGTH OF CONTINUOUS STRAIQTT pRALNACF W/ PER OTHER TRADES. LINES W/ MIN I NUMBER OF CORNERS WHEN SAWCUTTING PERIMETER. DRAM_ / 1 CONCRETE REPAIRS AT WATERLINE -- ELEVATION SPILLWAY NOTES 1) EXCAVATE A`U NT(S) AS REQ'D TO -- COMPLETE CONCRETE REPAIRS AT WATERLINE. 2) DETERIORATED CONCRETE INCLUDES AREAS OF SPNIING AND DEIAMINMED CONCRETE. 3- 3) COWRACTOR SHALL DETERMINE EXTENT OF DELAMINATED CONCRETE BY HWMER SOUNDING OR SIMILAR MECHM MEANS. 4) COWRACTQR SHALL MARK F -EW OF DETERIOR4IED CONCRETE ON SURFACE OF DAM PAD RENEW W/ EOR PRIOR TO COMMENCING REPAIRS. 5) ESTIMATED QUANRTY OF WATERIINE REPAIRS (FOR COST ESTIMATING ONLY; CONTRACTOR SWILL DETERMINE IN FEW PER NOTE 3). A) HIGH HAMPTON LAKE: 150 SF B) JEWEL WCE:0 C) MCCONNELL LAKE: 1205E (E) CO C. DPM REPAIR AREA, 3� f BEYOND EKTEW OF V DETERIORATED CONI. TO EXTENTPRACTICAL, MAIOMIIELENGTHOF CO NUOUS57RAIGW LINES W/ MINIMAL NUMBER OF CORNERS WHEN A SAWCUTTINGPERIMETTOL. 1�2�1 CONCRETE REPAIRS AT DOWNSTREAM FACE -- ELEVATION SCALE: 1/z'=1' -P' NOTES 1) DETERIORATED CONCR ATEOCCNCRE E. OF SPAWNG AND DELAMINATED CONCRETE. 2) CONTFACIOR SH DETERMINE EXTENT OF DELANBNAIED CONCRETE BY HMTMER SOUNDING OR SIMRAR MECHANICAL MEANS. 3) CONDUCTOR SHALL MARK EXTEW OF DETERIORATED CONCRETE ON SURFACE OF DAM AND RENEW W/ EOR PRIOR TO COMMENCING REPAIRS. 4) ESITMATFD QUN4RTY aF 001VNS1AEAD1 2/5"2.1 REPAIRS (FOR COST ESTIIMTING ONLY; CON RAC DR SHALL DETERMINE IN FIELD PER NOTE 2): A) Ffl I HAMPTW LAKE: MO SF B) JEWEL LME: 0 C) WOONNEU LME: 120 SF 5) ESTIMATED QUfWRTY OF 4/5-11 REPAIR ARE INICLUDED IN NOTE 4. TYPICAL CONDMONS AT LOCH HAMPTON LME DPM WATERLINE TYPICAL CONDITIONS AT WCO NEl1 LME OM WATT30INE TYPICAL CONDITIONS AT MCCONNELL LAKE DMI, DOWNSTREMt TYPICAL CONDITIONS AT MCCON8ELL LME DPM. DOWNSTREAM 5 6 7 8 9 1 10 11 II 12 13 14 A 15 1 16 1 17 18 19 1 20 21 F.NE; N ,S o el = 3 V) Z< Z �. ►CQ` M x z O Cc O L i a 2 yy11 T a0 Ogg N M �Nu+Mi W u z Q K ty u ; m x N Q LLL Z u 00 a O 1 yp z V) < O u LLI a U � u, H 2' OQ Z J HI w 7 N Juacz W Q O W V)za u G ~ WFF- u Q_ W 7 � F F LA Q Z J w Q0Q U E J O w Z 5 Q w W r U 2 0.6 z w Y o ogw LU z = U d U Z O = O c Q ' _ () o u w w = zz W u B a w ND LLJ a ze^ -H LLO N A 07 o m 3 Z A O a Lt) S U 22 13 n TYPICAL CONDITIONS AT HILI HAMPTON LAKE DAM DOV44MEMT r_ s NOTES: PERFORM 5/5.11 REPAIRS AT CRACKED CONCRETE 1) CRACKS DESIGWITED FOR REPAIR INCLUDE 1� F THOSE WITH WDDtCEEDIE TH E20 MILS f 0r AND/EMORECEEDINSCENCE. Z 2) CONTRACTOR SWILL MARK CRACKS DESIGNATED FOR REPAIR WITM SPRAY PAINT OR i SIMILAR MEANS AND REVIEW W/ EOR PRIOR TO COMMENCING REPAIRS. / ; u i (F ftESTIMATED IMQUANTITY ONLY; CRACK REPAIRS SHALL ESTIMATING ONLY; CONTRACTOR SHALL DETERMINE IN FIELDPER NOTE 2): i S A) HIGH HAMPTON - 120 LF 5-2.1 5-21 B) ]EWEL TAKE: TOO V LF C) WOONEL LAKE: W LP 5) ESTIMATED QUANTITY OF i/S-2.1 REPAIR ARE CRACK IXCEEOING t20 MILS, M. INCLUDED IN NOTE 4. (E) CONC. DAM IMECTION PORT, TYP, OFFSET GRIND OFF EICRESCENCE ALONG E1-1/2" FROM CRACK, STAGGERED. LENGTH OF CRACK AND SEAL SURFACE n 1 CRACK REPAIRS AT DOWNSTREAM FACE — ELEVATION SCALE:1/2'4- T/DAM N K E WATER LEVEL _ _ V,I.F_ SAWCUT 3/4" DEEP AROUND PERIMETER OF IE) FULL -DEPTH REPAIR AREA, 3^ E BEYOND EXTENT OF PENETRATION DETERIORATED CONC. TO EXTENT PRACTICAL, d, v C �`JO"iQ:N1 MAXIIRE LENGTH OF CONTINUOUS STRAIGHT LINES W/ MINIMA NUMBER OF CORNERS WHEN )rl SAWCUMNG PERIMETER. I I _ DETERIORATED COAG DRAY LAKE TO LEVEL REQ'D TO REVEAL FULL EXTENT OF DETERIORATED CONE. AT UPSTREAM FACE AND PROVIDE SUFFICIENT CLEARANCE FOR FULL -DEPTH REPAIR WORK. COORDINATE DRANACE W/ OTHER TRADES. I 0 OWNED WATER UBEL �_ McCONNELL LAKE -- FULL -DEPTH REPAIR -i SCALE: I12-=11' h A t T 5 (E) PENETRATION AT MCCONNELL LAKE DAM (E) PENETRATION AT MCCONNELL LAKE DAM PERFORM 3/S11 REPAIRS AT F -DEPT Yy PENETRATION +y\ W ki! TYPICAL CONDITIONS AT HIGH HAMPTON LAKE DAM WIMSTREAM TYPICAL CONDITIONS AT WCONNELL LAKE DAM D(AVNSTRFAM N L V) G z< Z d, v C �`JO"iQ:N1 0 u LVL, M ,o L V 0 W V 2 • # m�.�-i j N� N M N V K w V� v z w r, ak 2 ,E_N QT to N = N Kn Q d >_ CO �wvUO z+ Z L W 4E V M Z 02 LL F V a 6 � V) < o U 6 LLJ V -' V, H z O Q Z F- N J U m o W Q O W Z U G Q WV, r V Q Z � F I W W ~ N Q Z W 0 Y E g o Lu z aLu Lu U CY DV Z D w Y p � W_ Lu Z = u Z Z O = U ~Q O w w z L) s a Lu N Lu Z r-1 .--i o E N F- � GL V A y 00 5 Z O m2 Ln 0 22 123 (E) M. MNF. BARS, TYP. (E) CON[. DAM a (E) CONC DAN PROVIDE EXPOSED AGCR. SURF. PROFILE OF PROVIDE SATURATED SURFACE DRY (SSD) . (E) STI.. BARS, TYP. 31/8" (CSP ]d), SATURATED SURFACE qty SUn. mw. W/ NO STANDING WATER (SSD) SURFACE W/ NO STANDING WRIER SAWCUT 3/4" AROUNO PERIMETER OF REPAIR AREA HAND APPLY 5(KA AIu4ATEC 110 EPOCEM - 4 SAWCUi -'—U- PERIMETER OF REPAIR AREA HAND APPLY SIKA MMATEC 310 EPOCEM TO EXPOSED AND CLEANED REINF. N EXPOSED AND CLEANED REINF. CIDP AWAY CONC. TO SOUND SUBSTRATE, 2" MIN. DEPTH. ONE-HALFINSTALL SIKACRETE 2115[[ PLUS REPAIR ° CHIP AWAY CONC TO SOUND SUBSTRATE, 2' M]N. a FORM AND POUR OR HAND -APPLY DAM THICXNESS MAX DEPTH. REMOVE DIRT, OIL, GREASE, LAITANCE, MORTAR PER MANUF. SPECIFICATIONS DEPT. ONE-HALF DAN THICKNESS MAX DEPTH. SB(ACRETE 211 SCC PLUS REPAIR MORTAR AND Al BOND-IN.BITING MATERIAS FROM SURFACE. PROW DE a REMpYE DIRT, 0[L, GREASE, WTAIucE, AND ALL PER MANUF. SPECIFICATIONS EXPOSED AGGR. SURF. PROFILE OF 11/8" (CSP 7-8).APPLY SIKATOP SEAL -107 8CND-INHIBITING MATERNLS FROM SURFACE. WATERPROOFING PER MANUF. OVE USE WIRE BRUSH TO REMSPECIFICATIONS, MIN. (2) COATS. USE WERE BRUSH TO REMOVEAPRY SIKAGARD 705E SEALER PER CORROSION FROM EXPOSED REINF. a EXTEND OVER MANUF. OF DAM. a CORROSION FROM EXPOSED REINF. MAF. SPECIFICATIONS TO DOWNSTREAM FACE OF DAN NOTES: EXTEND WATERPROOFING FROM 4 • NOTES: ° TOP OF DAM TO 4" MIN. BEYOND 1) WHERE NO REIW. BARS ARE EXPOSED, INSTALL v REPAIR AREA 1) WHERE NO REINF. BARS ARE EXPOSED, INSTALL SUPPLEMENTAL REINF. BARS PER DETAIL 6/SL1 SUPPLEMENTAL REW. MRS PER DETAIL 61S-2.1 2) WHERE CRACK OR COLD DONT EXPOSED W/IN 2)ME CRACK OR COD ]DINT EXPOSED 'WIN REPAIR AREA REPAIR PER DETAIL 4/5-2.1REPAIR AREA, REPAIR PER DETAIL 4/52.1 REPAIR AREA PREPARATION REPAIR INSTALLATION REPAIR AREA PREPARATION REPAIR TSTA LATION ALT. 1-S55A5 fE211 SCC PLUS REPAIR MORTAR / 1 CONCRETE REPAIR DETAIL -- WATERLINE -2 SCALE: 3/P=11' [ CONCRETE REPAIR DETAIL -- DOWNSTREAM (;;6 SCALE: 3/'=1b" (8) .4. 12" DOWEL W/ SIMPSON SET (8) #4 X 12" DOWEL W/ SIMPSON SET EIPDXY. (2) DOWELS Ek. FACE, a 6" O.C.EXPDXY. (2) DOWELS ESI FACE, CSI 6" O.C. EMBED 6. INSTALL AS CLOSE TO {-- EMBED 6". INSTALL AS CLOSE TO 3/4" AROUND PETER OF ' • s PERPENDICULAR TO FACE AS PRACTICAL. SAWM ERIMa7 k— PERPENDICULAR N FACE AS PRACTICAL. 'F� REPAIR AREA, BOTH FACES OF DAM / FORM AND POUR ORC PLUS REPAIR / MACHINE M SIKACEM 133 REPAIR 51NACRETE 211 KC PLUS REPAIR MORTAR f MORTAR PER MANU, SPECIF[CAnONS CHIP AWAY CONC. TO SOUND SUBSTRATE, 2" MIN. PER MANUF. SPECIFICATIONS DEPTH. ONE-HALF DAM THICKNESS MAX DEPTH. CONFIRM SOUND SUBSTRATE WIN (E) PENETRATION �� PROVIDE EXPOSED AGCR SURF, PROFILE OF �� PROVIDE EXPOSED AGGR SURF. PROFILE OF REMOVE DIRT, OIL, GREASE, IATTANCE, AND PLL PPPLY SIKATOP SEAL -10] 33/B" (CSP ]-B), SATURATED SURFACE DRY pppLY SIKFTOP SEAL -10] 11/16" (CSP 6), SATURATED SURFACE DRY BOND-NIIIBTTING MATERIA -5 FROM SURFACE. WATERPROOFING PER MANUF. (55D) SURFACE W/ NO STANDING WATER WATERPROOFING PER MANUF. (SSD) SURFACE W/ NO STANDING WATER SPECIFICATIONS, MN. (2) COATS. SPECIFICATIONS, MIN. (2) COATS. EXTEND OVER TOP OF DAN, APPLY I XAGARD 705L SEALER PER El(TEND OVER TOP GF DAN. APPLY SIKAGARD ]DSL SEALER PER (E) Sn. RENF. BARS, TYP. MANUF. SPECIFICATIONS N MANUR SPECIFICATIONS TO DOWNSTREAM FACE OF DANDOWNSTREAM FACE OF DAN REPAIR CONCRETE BELOW (E) EXTEND WATERPROOFING HAND APPLY SIKH PRMATEC 110 EPOCEM EXTEND WATERPROOFING A HAND APPLY SIKH ARNMTEC 1l0 EPOCEM PENETRATION PER DETAIL 2/52.1 TO 4, MN. BEYOND TO EXPOSED AND O EAWD REINF. TO 4" MN. BEYOND N EXPOSED AND CLEANED REINF. • REPAIR AREA REPAIR AREA • 4 REPAIR AREA PREPARATION NOTE: FULL-0EPIH COIOETE REPAIR PROCEDURE MAY CE ADAPTED FOR USE WMFTE REQ'D AT VALVE REPLACEMENT. REPAIR AREA PREPARATION ? .DAM DRILL 5/8" 0 MOLE ALONG CRACK ® 45° ANGLE, SPACED 9 I2" O.C., TYP. OFFSET t1-112" FROM CRACK STAG FRED. GRIND OFF EFFLORESCENCE AND 5EAL SUR OF CONC. W/ SMADUR 31 MI -MOO GEL PER MANUF. SPECIFICATIONS, 3" MIN. EA SIDE CRACK. CRACK DESIGNATED FOR REPAIR. WIDTH EXCEEDS 120 MILS, TYP. REPAIR INSTALLATION ALT. I - SIKACRETE 211 KC PLUS REPAIR MORTAR 3FULL-DEPTH CONCRETE REPAIR REPAIR INLSTAL ATION (; 5 CRACK REPAIR DETAIL -2, SCALE IWECT SIKAFIX HH POLYURETHAI (ROUT PER MANUR SPECIFICATII CONTINUE IWECTING UNTIL GRO APPEARS AT ADJACENT HOLE. AR COMPLETING (4) HOLES, RETURN FIRST HOLE AND REPEAT, REPAIR INISTAL1AnON ALT. 2 - SIKACEM 133 REPAIR MORTAR MACHINE,NVPLIED REPAIR INSTALLATION CUT OFF IWECTION PORTS AND GRIND SEALANT RUSH W/ CONC. (E) CONC. DAM (E) STL REINF. BARS, TP. PREPARE REPAIR AREA PER DETAIL 2/52.1. • CRACX OR COD DUDU DESIGNATED FOR REPAIR REVEALED RING CONC.REMOVAL . REPAIRCRACK PER DETAIL S/5-2.tA . REPAIR AREA PRE➢ARAnON/ INTERNAL CRACK REPAIR A• PROVIDE EXPOSED AGGR SURF. PROFILE OF • 11/16(CSP 6), SATUMTED SURFACE DRY (SSD) SURFACE W/ NO STANDING WATER HMD APPLY SI(A ARMAnC 110 EPOCEM TO EXPOSED AND CLEANED REINF. • MACHINE APPLY SIKACEM 133 REPAIR MORTAR PER MANUP. SPECIFICATIONS •APPLY SII AGARD ASL SEAIER PER MANUR SPECIFICATIONS TO 9 DOWNSTREAM FACE OF DAM REPAIR INSTALLATION ALT.2- SIKACEM 133 REPAIR MORTAR MACHINE -APPLIED FORM AND POUR OR MACHINE APPLY REPAIR . MORTAR PER DETAIL 2/5-2.1 • CUT OFF IN, [,'PORTS PER DETAIL 5/52.1. SEALANT TORE N N PLACE. APPLY SIKAGARD ]DSL SEALER PER • MANUR SPECIFICATIONS TO DOWNSTREAM FACE OF DAM CONCRETE REPAIR INSTALLATION 4 \COMBINED DELAMINATION/CRACK REPAIR DETAIL -2 SCALE: 3/F -0' (E) CONC. DAM 1/4" 0 THREADED ROD (OR #3 MIN F. BAR) W/ SIMPSON SET EPDXY, 4" MIN. EMED. PROVIDE 135° BEND. INSTALL (1) PER SQ. FT. OF REPAIR AREA (MIN (2) PER REPAIR AREA) CONT. USI" m THREADED ROD (OR #3 REIN F. BAR) PREPARE CON[ SUBSTRATE AND INSTAII REPAIR MORTAR PER DETAILS 1 OR 2/5-2.1. SAWCUT 3/4" AROUND PERIMETER OF REPAIR AREA 6 CONCRETE REPAIR DETAIL NO REINFORCING EXPOSED S -L. S.o4: 3'=1'-0- (J ) Q a. W 0� G Q Lu U Z 0 U z .^f 00 oM It L(1 c� G Q Lu Y g J W U Lu z r W (n of LU LU g= O cd G Q ,r --I N Z O E 0 Z Q 0 0 Z D ce n 0- LLl ce W 0 1- a U z 3 O ov HIGH HAMPTON DAM REPAIRS HIGH HAMPTON COUNTRY CLUB JACKSON COUNTY, NORTH CAROLINA DRAWING SET CONTENT SHEET NO. SHEET TITLE C -1A COVER SHEET C -2A NOTES SHEET C-3.0 SITE PLAN/PROFILE L)AIA 5WLK PROPERTY OWNER: HIGH HAMPTON RESORT, LLC 3 SHEEP LAUREL ROAD CASHIERS, NC 28717 CONTACT PERSON: OWEN SCHULTZ VICE PRESIDENT - HIGH HAMPTON DANIEL COMMUNITIES OFFICE 828-743-6762 CELL* 828-506-0880 DESPROFESSIONAL- WALT DINIODUA PE ANCHOR QEA OF NC, PLIC 231 HAYWOOD STREET ASHEVILLE NC 28801 CONTACT: WYATT EDSEL, PE WFDSEI OANCHORQEACOM (828)281-3350 PROJECT NAME: HIGH HAMPTON DAM REPMRS PROJECT LOCATION: 1525 HIGHWAY 107 SOUTH CASHIERS, NC 28717 PIN 4:7571-96-2365 PROPERTY SIZE: 21952 ACRES VICINITY MAP NOT TO GENERAL NOTES: (APPLICABLE TO ALL SHEETS) 1. THIS PLAN WAS PREPARED WITHOUT THE BENEFIT OF AN IMPROVEMENTS OR TOPOGRAPHIC SURVEY. 2. T 5 THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ELEVATIONS IN THE HELD. 3. PROJECT TO BE CONSTRUCTED IN 1 PHASE 4. ALL IMPROVEMENTS, MATSU" AND METHODS SHALL CONFORM TO THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES, LATEST EDIT)ON, UNLESS OTHERWISE NOTED ON THE PLANS OR SUPERSEDED BY ANOTHER JURISDICTION HAVING AUTHORITY (JEW. S ALL PAVEMENT MARKINGS SHALL CONFORM TO NCDOT STANDARDS. 6. ALL TRAFFIC CONTROL SIGNS SHALL CONFORM TO THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES STANDARDS, LATEST EDTIM. 7. THE CDNTRACIOR SHALL PROTECT DUSTING PROPERTY MONUMENTATION AND PRIMARY CONTROL ANY SUCH POINTS WHICH THE CONTRACTOR BELIEVES WILL BE DESTROYED SHALL HAVE OFFSET POINTS ESTABLISHED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. ANY MONUMENTATiON DESTROYED BY THE CONTRACTOR SHALL BE REESTABLISHED AT HIS NSE &&TESHALL BE THE RESPONSIBILITY OF THE CONTRACTOR 70: A) PREVENT ANY DAMAGE 70 PRIVATE PROPERTY AND PROPERTY OWNER'S POLES, FENCES, SHRUBS, ETC BJ PROTECT ALL UNDERGROUND UTILITIES C) NOTIFY ALL UTILITY COMPANIES AND FIELD VERIFY HORIZONTAL AND VERTICAL LOCATION OF ALL UTILITIES PRIOR 70 START OF CONSTRUCTION. NOTIFY OWNER OF ANY POTENTIAL CONFLICTS WHICH MAY DOST BETWEEN THE EXISTING UTILITIES AND CONSTRUCTION PLANS. 9. BARRICADING AND TRAFFIC CONTROL DURING CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL CONFORM 70 THE NCDOF STANDARD SPECIRCATIONS AND DRAWINGS PEDESTRIAN AND VEHICULAR TRAFFIC FLAW SHALL BE MAWAINED DURING ALL PHASES OF THE OON57RUCTK)N. THE CONTRACTOR S RESPONSIBLE FOR PROVIDING TRAFFIC SAFETY MEASURES FOR WORK ON PROJECT. IM CONTRACTOR SHALL MAINTAIN DRAINAGE AT ALL TIMES DURING CONSTRUCTION. PONDING OF WATER IN STREETS, DRIVES, TRUCK COURTS, TRENCHES, ETC. WILL NOT BE ACCEPTABLE 11. ANY DAMAGES THAT MAY OCCUR 70 REAL PROPERTY OR COSTING IMPROVEMENTS SHALL BE RESTORED BY THE CONTRACTOR 70 AT LEAST THE SAME CONDITION THAT THE REAL PROPERTY OR EXISTING IMPROVEMENTS WERE IN PRIOR TO THE DAMAGES THIS RESTORATION SHALL BE SUBJECT TO THE OWNER'S APPROVAL; MOREOVER THIS RESTORATION SHALL NOT BE A BASS FOR ADDITIONAL COMPENSATION 70 THE CONTRACTOR RESTORATION SHALL INCLUDE. BUT NOT BE UMRED TO, REGRASSING, REVEGETATION, REPLACING FENCES, REPLACING TREES, ETC 12. WHERE PRESENT, CONTRACTOR SHALL MAINTAIN EXISTING SANITARY SEWER AND WATER SERVICE AT ALL TIMES DURING CONSTRUCTION. 13. CONTRACTOR S RESPONSIBLE FOR COORDINATION WITH UTILITY COMPANIES AND ADJUSTMENT OF EXISTING SANITARY SEWER CLEANOUTS, WATER METERS AND ANY OTHER APPURTENANCES TO NEW GRADE AS REQUIRED. 14. CONTRACTOR 5 RESPONSIBLE FOR COMPLYING WITH ALL APPLICABLE LOCAL STATE AND FEDERAL S70RM WATER POLLUTION PREVENTION LAWS AND ORDINANCES 15. PAVEMENT REMOVAL AND REPAIR SHALL CONFORM 10 NCDOT REQUIREMENTS ALL SAWCUTS SHALL BE FULL DEPTH CURS. CONTRACTOR SHALL MAKE EFFORTS 70 PROTECT CONCRETE EDGES ANY LIGE SPALLED OR BROKEN EDGES SHALL BE REMOVED BY SAWCUTTING PAVEMENT PRIOR TO REPLACEMENT. 16. CONTRACTOR SHALL BE RESPONSIBLE FOR MANTANING ALL EROSION CONTROL MEASURES THROUGH THE COMPLETION OF THE PROJECT AND THROUGH THE ESTABLISHMENT OF VEGETATION SUFFICIENT 70 PROVIDE EROSION PROTECTION. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL TEMPORARY EROSION CONTROL MEASURES PRIOR TO PROJECT CLOSE-OUT. 17. PRIOR TO BEGINNING CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY THAT ALL REQUIRED PERMITS AND APPROVALS HAVE BEEN OBTAINED FROM ALL REGULATORY AUTHORITIES. 1& ALL DISTURBED AREAS ARE TO BE STABILIZED AND SEEDED WITHIN 14 DAYS OF DISTURBANCE UNLESS OTHERWISE NOTED. 1. UNLESS OTHERWISE NOTED M ACCORDANCE WITH APPENDD( J 2. THE SURFACE OF AREAS TO BE GRADED SHALL BE PREPARED TO RECEIVE FILL BY L. AND OTHER UNSUITABLE MATERIALS, AND SCARIFYING VD WITH THE FILL MATERIAL EDS 5:1(HORQONTALNERTICAL) AND THE DEPTH OF FILL LL BE PROVIDED. A 2 -FOOT DEEP BY 10 -FOOT WIDE KEY OF THE FILL SLOPE REM 70 NC BUILDING CODE SECTION SHALL BE PERFORMED IN 4. CERTIFICATION OF CUT AND FILL SLOPES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE MADE BY A GEOTECHNICAL 04GNEER LICENSED TO PRACTICE IN THE STATE OF NORTH CAROLINA. UNLESS OTHERWISE NOTED, ALL CUT AND RLL SLOPES PROPOSED BY THESE PLANS SHALL BE 2:1(NORIZONTALNERiICAL) OR FLATTER S. CUT AND FILL SLOPES (EMBANKMENis) SHALL BE CONSTRUCTED IN ACCORDANCE WITH NCDOT STANDARD SPECIFICATION SECTION 23S OR THE GEOTECHNICAL (SOILS) REPORT RECOMMENDATIONS, WHICHEVER IS MORE RESTRICTIVE AT A MINIMUM, ALL RLL SLOPES SHALL BE PLACED N 1044CH MAXIMUM LIFiS COMPACTED 70 NOT LESS THAN 9S PERCENT DENSITY (STANDARD PROCTOR). CONTRACTOR SHUT ARRANGE FOR INDEPENDENT COMPACTION TESTING RESULTS TO BE PAID FOR BY THE OWNER/DEVEDPEI. 6. NO GRADING SHALL OCCUR WITHIN 2 FEET OF A PROPERTY LINE WITHOUT WRITTEN PERMISSION FROM THE ADJACENT PROPERTY OWNER 7. UNLESS OTHERWISE INDICATED IN THESE PLANS TERRACES SHALL BE PROVIDED AS FOLLOWS: WHERE GRADES EXCEED 3:1 (HORROMALNERIICAL), TERRACES AT LEAST 6 FEET IN WIDTH SHALL BE CONSTRUCTED AT NOT MORE THAN 30 -FOOT VERTICAL INTERVALS ON ALL CUT OR FILL SLOPES. SWALES SHALL BE PROVIDED ON TERRACES IN ACCORDANCE WITH NC BUILDING CODE SECTION J109. & FINE GRADING AND SEEDING SHALL OCCUR AT ALL AREAS DISTURBED BY THE WORK OF THE PROJECT THAT ARE NOT PROGRAMMED FOR PAVEMENT OR BUILDINGS. 9. FINE GRADING SHALL INCLUDE APPLICATION OF 2-3 INCHES OF TOPSOIL AND REMOVAL OF ALL DEBRIS (ROOTS, ROCKS, TRASH, AND OTHER FOREIGN MATERIAL) LARGER THAN 2 INCHES IN ANY DIMENSION. FINE GRADING SHALL ACHIEVE POSITIVE DRAINAGE AWAY FROM BUILDINGS AND IN GENERAL ACCORDANCE WITH THE DRAINAGE PLANS. LANDSCAPE AREAS SHALL NOT BE SLOPED LESS THAN 296. 10. GROUND COVER REQUIRCMENiX ALL DISTURBED AREAS SHALL BE PLANTED WITH AN APPROVED GROUND COVER WITHIN 14 CALENDAR DAYS. ALL PERIMETER DIJU SWAT M DITCHES, PERIMETER SLOPES, AND ALL SLOPES STEEPER THAN 3:1 MUST BE STABILIZED IN 7 DAYS. SLOPES 50' OR GREATER IN LENGTH MUST BE STABILIZED WITHIN 7 DAYS EXCEPT WHEN THE SLOPE S HATTER THAN 4:1. SLOPES LESS THAN SO' MUST BE STABIL® IN 14 DAYS EXCEPT WHEN THE SLOPE S STEEPER THAN 3:1, THENTHE 7 DAY REQUIREMENT APPLIES. INSTALL TEMPORARY SEEDING ON ALL AREAS THAT WILL BE LEFT IDLE FOR MORE THAN 14 DAYS. HARDWOOD MULCH 5 AN ACCEPTABLE TEMPORARY COVER BUT MAY NOT BE BLENDED INTO THE: SUBGRADE AND WILL BE REQUIRED TO BE REMOVED PRIOR M CONTINUATION OF THE WORK FOR PROJECT AREAS WITHIN THE "HIGH QUALITY WATER ZONE' (ISA NCAC 04A0705), STABILIZATION SHOULD BE ACHIEVED AS SOON AS PRACTICABLE BUT NO UTTER THAN 7 DAYS. 11. DUST CONTROL CONTRACTOR SHALL BE RESPONSIBLE FOR CDNTROLU14G DUST GENERATED BY THE WORK OF THE PROJECT. INSTALL TEMPORARY OR PERMANENT SURFACE STABIIIATION MEASURES IMMEDIATELY AFTER COMPLETING LAND DISTURBANCE. LANDSCAPE AREAS SHALL BE PLANTED AND STABLED WiFH MULCH OR GROUNDCOVER AS SOON AS POSSIBLE AREAS SUBJECT TO TRAFFIC SHALL BE STABILIZED WITH THE APPLICATION OF WATER (SPRINKUNG). SPRAY -ON ADHESIVES (E.G. ASPHALT EMULSION, ETCJ, CALCIUM CHLORIDE OR STONE DUST CONTROL SHALL INCLUDE THAT CAUSED BY SAW -CUTTING AND SIMILAR DUST GENERATING ACTMTIES. WIND FENCE OR SIMILAR BARRIERS MAY BE REQUIRED DURING PARTICULARLY WINDY, DRY CONDITIONS TILLAGE (LE DEEP PLOWING TO BRING CLADS TO THE SURFACE) MAY BE USED AS AN EMERGENCY MEASURE FOR LARGE OPEN AREAS. DUST CONTROL MEASURES SHALL BE MAINTAINED BY THE CONTRACTOR THROUGHOUT THE DRY WEATHER UNTIL ALL DISTURBED AREAS ARE STABLED. 1. STRAW MULCH AND TALL FESCUE SHOULD NOT BE USED IN RIPARIAN AREAS Z IF CONCRETE 5 USED (EG HEADWALLS), A DRY WORK AREA MUST BE MAINTAINED TO PREVENT DIRECT CONTACT BETWEEN CURING CONCRETE AND STREAM WATER WATER THAT INADVERTENTLY CONTACTS LIVE CONCRETE MUST NOT BE DISCHARGED TO SURFACE WATERS DUE TO THE POTENTIAL FOR WATER CHEMISTRY CHANGE AND FSH KILLS 3. ROCK SAND OR OTHER MATERIALS MUST NOT BE EXCAVATED FROM THE STREAM CHANNELS EXCEPT IN THE IMMEDIATE VICINITY OF THE CULVERT LOCATIONS. THE NATURAL DIMENSION, PATTERN, AND PROFILE OF THE CHANNEL UPSTREAM AND DOWNSTREAM OF THE CULVERT MUST NOT BE MODIFIED. 4. SANDBAGS, REKIBLE PPE OR OTHER DIVERSION STRUCTURES SHOULD BE USED TO AVOID EXCAVATING N ROWING WATER MATERIALS USED FOR FLOW DIVERSION SHOULD BE REMOVED FROM THE STREAM BED AFTER CDMPLETNG THE CONSTRUCTION WORK ANY DIVERSION CHANNELS MUST BE LINED WITH FILTER FABRIC AND/OR ROCK S. ROCK AND OTHER MATERIALS PLACED TEMPORARILY N STREAMS FOR FORDS MUST BE REMOVED AND THE STREAM CHANNELS RESTORED 70 DUSTING CONDITIONS AFTER THE FORDS ARE NO LONGER NEEDED. & RIPARIAN VEGETATION ESPECIALLY TREES AND SHRUBS, SHOULD BE PRESERVED AS MUCH AS POSSIBLE NATIVE WOODY VEGETATION (EG. RHODODENDRON, DOG HOBBLE, SILKY DOGiMOOD, SYCAMORE RIVER BIRCH, RED MAPLE) SHOULD BE REESiABLISHED DOWNSTREAM OF THE CULVERTS AND FORD IF iT 5 REMOVED DINING CONSTRUCTION TO PROVIDE BANK STABILITY AND SHADING. THE USE OF NATIVE DAMS THAT MUST BE WATERS FROM FUELS, LUBRICANTS, HYDRAULIC FLUIDS OF OTHER �nru vJ-btw MLA I unts AND WASHING OUT HYDROSEEDERS AND OTHER EQUIPMENT IN OR ADJACENT 70 SURFACE WATERS 5 PROHIBITED. 9. EROSION AND SEDIMENT CONTROL MEASURES SHALL BE INSPECTED DAILY AND AFTER ANY "FALL DEFICIENCIES SHALL BE CORRECTED IMMEDIATELY. A DAILY RECORD SHALL EROSION AND EROSION CONTROL SCHEDULE: (APPLICABLE TO ALL SHEETS) THE EROSION AND SEDIMENTATION CONTROL PLAN IS DESIGNED FOR THE COMPLETED GRADED CONDITION IN ACCORDANCE WITH THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL. LATEST EDITION. IT IS THE CONTRACTORS RESPONSIBILITY 7O MAINTAIN AND PROVIDE ADDITIONAL EROSION AND SEDIMENTATION CONTROL. MEASURES AS NEEDED BETWEEN THE TIME THE GRADING OPERATION S BEGUN AND THE TIME R 5 COMPLETED. THE ENGINEER 5 AVAILABLE AS NEEDED FOR CONSULTATION ON SELECTING AND SONG APPROPRIATE INTERIM MEASURES WHEN THEY MAY BE REQUIRED, CONSTRUCTION SHALL PROCEED IN ACCORDANCE WITH THE FOLLOWING SCHEDULE 1. MAINTENANCE -MAINTENANCE OF EROSION AND SEDIMENTATION CONTROL MEASURES SHALL INCLUDE INSPECTIONS PERFORMED ON A WEEKLY BASIS AND AFTER EVERY RAINFALL EVENT. MAINTENANCE CLEANING AND REPAIRS SHALL BE MADE IMMEDIATELY. CONTRACTOR SMALL MARIE 96PECTIONS AND REPAIRS AS NEEDED DURING PERIODS OF SM34DFD RAINFALL 2. CONSTRUCTION ACCESS - APPLICABLE TO CONSTRUCTION ACAS CONSTRUCTION ROUTM AND EQUIPMENT PARKING AREAS. INSTALL STABILIZED CONSTRUCTION ENTRANCE, ACCESS ROUTES AND PARKING AREAS. MUDDY AND RUTTED PATHS ARE NOT ACCEPTABLE STABILIZE BARE AREAS IMMEDIATELY WITH GRAVEL, MULCH, AND TEMPORARY VEGETATION AS CONSTRUCTION TARES PLACE 3. SEDIMENT TRAPS AND BARRIERS -APPLICABLE TO BASIN TRAPS, SEDIMENT FENCES, AND OUTLET PROTECTION. INSTALL PRINCIPAL BASINS AND SILT FENCE IMMEDIATELY AFTER CONSTRUCTION GRADING ACCESS. INSTALL ADDITIONAL TRAPS AND BARRIERS AS NEEDED DURING 4, RUNOFF CONTROL -APPLICABLE TO DIVERSIONS, PERIMETER DICES, WATER BARS, AND OUTLET PROTECTION. INSTALL LEY PRACTICES AFTER SEDIMENT TRAPS AND BARRIERS AND PRIOR 70 GRADING INSTALL ADDITIONAL RUNOFF CONTROL MEASURES AS NEEDED DURING GRADING. S. RUNOFF CONVEYANCE SYSTEM -APPLICABLE TO STREAM BANKS, STORM DRAINS, CHANNELS, INLET. AND OUTLET PROTECTION, AND SLOPE DRAINS. INSTALL PRINCIPAL RUNOFF CONVEYANCE SYSTEM CONCURRENTLY WITH RUNOFF CONTROL MEASURES. WHERE APPLICABLE STABILIZE STREAM BANKS PRIOR TO GRADING OBTAIN PROPER PERMITS FOR ALL WORK IN STREAMS. SPRINGS, AND OTHER JURSDILTIONAL AREAS. & LAND CLEARING AND GRADING- APPLICABLE TO SITE PREPARATION, CUTTING, FILUNG, AND SURFACE ROUGHENING MARK TREE AND BURflt AREAS AND INSTALL APPROPRIATE PROTECTION POOR TO CLEARING AND GRADING. BEGIN MAJOR CLEARING AND GRADING AFTER PRINCIPAL SEDIMENT AND LEY RUNOFF CONTROL MEASURES ARE INSTALLED. CLEAR BORROW AND DISPOSAL AREAS ONLY AS NEEDED. INSTALL ADDITIONAL CONTROL MEASURES AS GRADING PROGRESSES 7. SURFACE STABIL17ATI N - APPLICABLE TO TEMPORARY AND PERMANENT SEEDING, MULCHING, SODDING, AND RIPRAP. APPLY TEMPORARY OR PERMANENT STABILIZATION MEASURES IMMEDIATELY ON ALL DISTURBED AREAS WHERE WORK 5 DELAYED OR COMPLETE & BUILDING AND SiTE CONSTRUCTION -APPLICABLE TO BUILDINGS, STRUCTURES. UTIUf1ES AND PAVWG. MODIFY AND MAINTAIN EROSION AND SEDIMENTATION CONTROL MEASURES AS CONSTRUCTION PROGRESSES. INSTALL ADDITIONAL MEASURES AS NEEDED TO RESPOND 70 CHANGES IN SITE CONDITIONS. 9. LANDSCAPING AND FINAL STABILIZATION -APPLICABLE TO 7OPSO1UNG, TREE AND SHRUB PLANTING, PERMANENT SEEDING, MULCHING, SODDING AND RIPRAP. STABILIZE ALL OPEN MEAS, NCLLUDING BORROW AND SPOIL AREAS. REMOVE ALL TEMPORARY EROSION CONTROL MEASURES, INCLUDING SILT FENCE AND STAKES STABILIZE ALL TEMPORARY CONTROL AREAS. OBTAIN FINAL APPROVAL BY ENGINEER AND AUTHORITY HAVING JURISDICTION. I. PROJECT DESCRIPTIO►: THE PURPOSE OF THIS PROJECT S TO PERFORM REPAIRS 1� HIGH HAMPTON LAKE N$ERLAQ TIM VAjVr JTE TO THE DAM, THE LAZE BED UPSTREANTICW M OF THEDIKA AND THE DMMM ITSELF. AREAS OF PRESERVATION INCLUDE THE RIVER CHANNEL DOWNSTREAM AND PORTIONS OF THE DAM NOT RECEIVING REPMRS 2. SiTE DESCRIPTION: THE SITE 5 THE HIGH HAMPTON LAAO: DAM IN CASHIERS, NORTH CAROLINA THE PROPERTY 5 A GOLF CLUB WITH THE SURROUNDING AREAS BEING FOREST AND THE LAND:6 ROLLING HILLS AND SOME STEEPER SLOPES. THE DAM TO BE REPAIRED IS A CONCRETE DAM WITH A WOODEN DECK BUILT ON THE TOP OF THE WESTERN EDGE 3. ADJACENT PROPERTY: ADJACENT PROPERTIES ARE PRIMARILY RESIDENTIAL WITH SOME COMMERCIAL THE SITE AND SURROUNDING AREAS DO NOT APPEAR TO BE SUBJECT TO ACTIVE EROSION. 4. OBTAIN LAND DISTURBING PERMIT FROM JURISDICTION HAVING AUTHORITY, AND ATTEND PRE CONSTRUCTION MEETING. AFTER CONSTRUCTION AND ALL DISTURBED AREA HAVE BEEN STABILIZED, CONTRACTOR SHALL REMOVE ALL TEMPORARY SEDIMENT CONTROL MEASURES. REQUEST FINAL APPROVAL FROM ENGINEER AND JURISDICTION HAVING AUTHORITY. W H W O N 0i� •T� 1. ,EFLEII TO NnhAA�R DAM REPIJR a 10' VALVE EXTENDER To MANUAL ACTUATDR -j J rEN X7/2'VALVE EXTENDER TDMANUAL ACT MR (MOUNTED TOF�ACLLE OF �M T NED I)N ►�5RROlIND THE E D F DAM. INSTALL 2' DeZURIK KGC HD KNIFE GATE VALVE PEF 100% PORT ECCENTRIC AT FULL 54211 NOT ON: KIIOIY IYII� MIO. ON b*m db. U .1V1:.\ IT IN 11 RNA11011L st11.UT1011 _(q l'ka�anl Rim 17, Sm1ma TN i1 Plwlc. I5nl1111-IRIRIS ..'.> t .-fi n rma W OF It— (F"�t `x+ TOP FL -_M __M/_ _ CONCRETE WET WELL INTERNAL DEPTH YI.00R FI -_\I LI 1-111–III-111-111–III–II O F. K'FIRSTRt'MAF/OVERFLOWFL. M III—III-1111-111 1—III 111-111=111-111-111–III u II–III–III–III–III–III–III _ 111-III-III-III=IT=III=III-III 1=III=111=III=1_I1=111=11 a .o WA R L-_ 1=111=111–I I I -111–I I p IR,_ �rr1- –111-111-111–I I I -111–I I–I I-111-111-111-111-111 ROUND WE" 111 __ __ II1=1 1El II E¢. _ _ _ _ _ _ __ _ 1=1 11 111 1111111111111111 —rr i I1=111-111-111-111–III-111-111-111-111-111–III-111–III–III–III — – — — – z � z __ _ _ _ _ _ ___________ — rl–rri`i I –I I-11 EI I I-111-11 I–I I I-111-11 I-1 11–I 1I–I 11=1 11–I 11–III–III-1 1 I–I 11-1 11=1 11=1 11-1 11=1 I z -- 111-111—IiI-111-111-111 O ` ].- SMOOTH BORE WALL MANE PIPE NOT TO EXCEED 100' W tCREEN 1=111=111=111=111=111=1I FL— -- a., 0 .� O_ _ _ _ Alm.l`- T _ III=III=III=111=111-111 [.-., U 4'�"t IIF��411 1 \AF R��I ItIM FI= At I\I:1NF.4RI:F.\l, SVI IARC: Ilr OR EVll.1L x NOTE: Periodic maintenance needed to titan amOnd and inside intake, p,p h —well Mnom. Hy ISI x GOLF IRRIGATION INTAKE STRUCTURE N.T.S o Date. SCALE N.T.S. DATE- 01 214.19 DESIGN BY - TAH DRAWN BY- TAH FILE NAME ~ PROJF.0 T NO. 1229 -IR REVISIONJ DATE SHEET IL IS Appendix A Anchor QEA Memorandum February 28, 2019 Anchor QEA of North Carolina, PLLC ANCHOR 231 Haywood Street Asheville, North Carolina 28801 QEA i..�..v 828.281.3350 Memorandum February 28, 2019 To: High Hampton Community From: Anchor QEA of North Carolina, PLLC cc: ClearWater Environmental Consultants, Inc. Re: High Hampton Dam — Anticipated Construction Sequence for Pre -Construction Notification (PCN) Anticipated construction sequence at High Hampton Dam for Pre -Construction Notification (PCN) purposes. • Construction is anticipated to occur in one phase over an 8 -week period. • The project is located in an environmentally sensitive area and is adjacent to a trout stream. The contractor shall use extreme care throughout project to maintain water quality standards. • Water level in the lake will be lowered using a sump pump, siphon, or a combination of both, and flows will not exceed a maximum rate of drawdown of 1 foot per day. • During the lake drawdown process, the contractor shall ensure the water being removed from the lake into the stream meets the turbidity requirements of the permit. If sediment becomes a problem during the dewatering process, the contractor shall contact the project engineer immediately and additional measures will be implemented. • Once the lake is lowered, the contractor shall maintain minimum base flow at all times to the stream of 0.475 cubic feet per centimeter (cfs) (7Q10). The minimum base flow shall be accomplished by using either a mechanical pump or siphon system (or a combination of both) that will operate throughout the maintenance and refilling process. • The project is located in an environmentally sensitive area and is adjacent to a trout stream. The contractor shall use extreme care throughout project to maintain water quality standards. • Once the sediment has had appropriate time to dewater, a temporary construction access will be installed to provide access to the upstream side of the dam. The construction access may consist of geotextile, rip rap, gravel, or crane mats, and will be removed when the project is complete. • Base flow will be maintained around/over the dam during staging and construction via an appropriately sized pump around system. 2019 -02 -Hampton Lake Dam Construction Sequence for permitting.docx February 28, 2019 Page 2 • The construction area will be isolated from the stream bed during staging and construction so that work is performed in the dry, with consideration for management of high flow events. • Accumulated sediment (approximately 55 cubic yards [cy] behind the dam) will be excavated to facilitate repairs. It is anticipated that a long-arm excavator will remove the sediment and place it directly into a dump truck. The excavated sediment will then be hauled to a location selected by the owner, and a silt fence will be installed around the perimeter of the sediment placement area. • To facilitate valve replacement, the contractor shall neatly and carefully sawcut and remove a 4 -foot by 4 -foot section of the dam to remove the old valve and pipe. The valve will be replaced by installing a fabricated spool piece, adding dowels into the existing concrete, and pouring new concrete around the spool piece in accordance with the engineering plans and specifications. • For crack repairs, the selected contractor shall determine the most feasible, cost effective, safest, and least impactful way to access the faces of the dam to complete the work. This could involve using scaffolding, ladders, ropes, or other measures. This could temporarily impact up to 30 linear feet of stream on the downstream side of the dam. These impacts will be temporary and will be removed when they are no longer necessary. • Following all work, disturbed areas upland of the normal water surface elevation of the lake will be stabilized and seeded. • The lake will be refilled by maintaining the minimal required downstream flow 7Q10 (0.475 cfs) through the new valve and control system. Jewel Lake will remain at normal pool elevation during maintenance of Hampton Dam. Two floating turbidity curtains will be installed in the lake until work is complete. We propose monitoring turbidity at the outlet of Jewel Lake for permit compliance.