HomeMy WebLinkAboutKnapheide Gravel - Knapeide Full Civil (02-04-2019)OVERALL CONSTRUCTION SEQUENCE 1. SETUP AN ON -SITE PRE -CONSTRUCTION CONFERENCE WITH NCDEQ EROSION CONTROL INSPECTOR AND TOWN OF MIDLAND REPRESENTATIVE TO DISCUSS CONSTRUCTION. FAILURE TO SDiEDULE SUCH CONFERENCE 48-HOURS PRIOR TO ANY LAND DISTURBING ACTIVITIES IS A VIOLATION OF LOCAL CODE AND MAY BE SUBJECT TO FINES OR OTHER PENALTIES. 2. SURVEY AND FLAG THE DENUDED LIMITS. 3. INSTALL CONSTRUCTION ENTRANCE. 4. INSTALL SILT FENCE, JUNCTION BOX, PIPE P1, SKIMMER SEDIMENT TRAPS, AND OTHER MEASURES (AS SHOWN ON THIS SHEET); CLEARING ONLY AS NECESSARY TO INSTALL THESE DEVICES. 4A. CONTRACTOR TO USE MOUND ON SITE FOR PHASE I EROSION TO BUILD SKIMMER SEDIMENT TRAPS AND ON -SITE BERMS PRIOR TO UTILIZATION OF BORROW AREA. 5. SEDIMENT TRAPS NEED TO BE STABILIZED IMMEDIATELY AFTER INSTALLATION. 6. INSTALL CONSTRUCTION ENTRANCE, SILT FENCE, AND STONE OUTLET AT BORROW SITE:, 7. CALL FOR ON -SITE INSPECTION BY NCDEQ INSPECTOR. WHEN APPROVED, CONTRACTOR MAY THEN BEGIN CLEARING AND GRUBBING THE REMAINING PORTIONS OF AREA. 7A. AS SITE IS BROUGHT TO FINAL GRADE DURING PHASE II EROSION, SST-1 MAY BE REMOVED SO LONG AS ALL WATER IS DIVERTED TO SST-2 AS SHOWN ON PLANS. 8. MAINTAIN EROSION CONTROL DEVICES AS NECESSARY. 9. STABILIZE SITE AS AREAS ARE BROUGHT TO FINISH GRADE REFER TO DETAIL SHEET C-6.1 FOR SEEDING, 10. CONTRACTOR TO COORDINATE WITH EROSION CONTROL INSPECTOR PRIOR TO REMOVAL OF ANY EROSION CONTROL MEASURES. EROSION CONTROL NOTES,• 1. ALL 'REFERENCE' NUMBERS REFER TO DEO MANUAL UNLESS OTHERWISE NOTED. 2. ON -SITE BURIAL PITS MAY REQUIRE AN ON -SITE DEMOLITION LANDFILL PERMIT FROM THE ZONING ADMINISTRATOR. 3. ANY GRADING BEYOND THE DENUDED LIMITS SHOWN ON THE PLAN IS A VIOLATION OF THE STATE EROSION CONTROL ORDINANCE AND IS SUBJECT TO A FINE. 4. GRADING MORE THAN ONE ACRE WITHOUT AN APPROVED EROSION CONTROL PLAN IS A VIOLATION OF THE COUNTY EROSION CONTROL ORDINANCE AND IS SUBJECT TO A FINE. 5. GROUND STABILIZATION: SEE ADJACENT NEW STABILIZATION TIMEFRAME CHART. 6. ADDITIONAL MEASURES TO CONTROL EROSION AND SEDIMENT MAY BE REQUIRED BY A REPRESENTATIVE OF THE TOWN, COUNTY OR NCDEQ. 7. SLOPES SHALL BE GRADED NO STEEPER THAN 2:1. FILL SLOPES GREATER THAN 10' REQUIRE ADEQUATE TERRACING. EMBANKMENT MATTING MAY BE REQUIRED FOR SLOPES STEEPER THAN IT BASED ON MATERIAL 8. A GRADING PLAN MUST BE SUBMITTED FOR ANY GRADING EXCEEDING ONE ACRE THAT WAS NOT PREVIOUSLY APPROVED. 9. TEMPORARY DRIVEWAY PERMIT FOR CONSTRUCTION ENTRANCES IN NCDOT RIGHT OF WAY MUST BE PRESENTED AT PRE-COSSTWCTION MEETING. (IF APPLICABLE) MdliM%Ath7RA1 L THE FCLLAMING MAINTENANCE PLAN SHALL BE FOLLOWED FOR EROSION AND SEDIMENT CONTROL DEVICES UNTL THE SITE IS COMPLETELY STABIIIED AND AFTER CONSTRUCTION FOR STORM WATER MANAGEMENT DEVICES THROUGHOUT THE UFECYC E OF THE DEVELOPMENT. DURING CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONS LE FOR INSPECTION AND MAINTENANCE OF ALL EROSION CONTROL FEATURES. FOLLOMING CONSTRUCTION. THE OMNER/RESPONSBLE PARTY IS RESPONSIBLE FOR INSPECTION AND MAINTENANCE OF ALL STORM WATER MANAGEMENT FEATURES 1. ALL EROSION CONTROL MEASURES WILL. BE CHECKED FOR STABILITY AND OPERATION FOLLOWING ANY RAN -FALL PRODUCING RUNOFF AT LEAST ONCE A WEEK. ANY NEEDED REPAIRS WALL BE MADE IMMEDIATELY 50 THAT ALL EROSION CONTROL MEASURES ARE MAINTAINED AS DESIGNED. 2. THE SEDIMENT TRAPS WILL BE CLEANED OUT WFETN THE LEVEL OF SEDIMENT REACHES APPROXIMATELY ONE HALF OF THE TRAP OR BASIN VOLUME. A ALL SEEDED AREAS WILL BE FERTILIZED. RE -SEEDED AS NECESSARY, AND MULCHED ACCORDING TO THE SEEDING SPECIFICATIONS AND THE RE EDIAT)ON PLAN IN ORDER TO MAINTAIN A DENSE VEGETATIVE COVER. 4. ALL SEEDED AREAS MILL BE RE -FERTILIZED IN THE SECOND YEAR UNLESS GROWTH IS FULLY ADEQUATE GRASSED AREAS MILL BE MOMED AT LEAST ONCE A YEAR. EFFECTIVE OCTOBER 1. 2010, PERSONS RESPONSIBLE FOR LAND DISTURBING ACTIVITIES MUST INSPECT THE SEDIMENT AND EROSION CONTROL MEASURES ON A PROJECT AFTER EACH PHASE OF THE PROJECT TO MAKE SURE THAT THE APPROVED EROSION AND SEDIMENTATION PLAN IS BEING FOLLOWED. SOY -INSPECTION REPORTS ARE REQUIED. A SAMPLE SEF-INSPECTION REPORT. AS WELL AS DETAILS OF THE SELF -INSPECTION PROGRAM. CAN BE FTXIND ON THE LAND QUALITY WEB SITE Attag//dsa.n-m 6&wf/dMNmro/�min� ---d- ---. ---/ ' - AS A MINIMUM, THE INSPECTIONS SHALL BE PERFORMED AFTER EACH OF THE FOLLOWING PHASES OF A PLAN: 1. INSTALLATION OF PERIMETER EROSION AND SEDIMENT CONTROL MEASURES. 2. INSTALLATION OF SEDIMENT TRAPS/BASINS 3. CLEARING AND GRUBBING OF EXISTING GROUND COVER. 4. COMPLETION OF ANY PHASE OF GRADING THAT REQUIRES PROVISION OF STABILIZATION. S. INSTALLATION OF MEASURES DURING ANY PHASE OF THE PROJECT. 6. COMPLETION OF CONSTRUCTION OR DEVELOPMENT. 7. INSTALLATION OF STORMWATER RETENTION MEASURES. & QUARTERLY UNTIL THE ESTABLISHMENT OF PERMANENT GRWND COVER IS FILLY ESTABLISHED. PLEASE NOTE THESE INSPECTION REQUIREMENTS ARE IN ADDITION TO NOTES INSPECTION REQUIREMENTS F YOU HAVE QUESTIONS ABOUT THE SELF -INSPECTION PRAM, PLEASE CONTACT US AT (704) E63-1699. LEGEND SUBJECT PROPERTY BOUNDARY ADJACENT PARCELS / RIGHT-OF-WAY INLET SCHEDULE: 702-- EXISTING TOPO - - -ss - - -ss - - - - ss EXISTING SANITARY SEWER EASEMENT JUNCTION BOX JB-1 _,_ RIM: 506.00 - - - -"w_- -- -- �'�'- - - -W- - EXISTING WATERLINE EXISTING CREEK CENTERLINE INLET INV. ELEV. = 501.93OUTLET INV. ELEV. = 501.73 20 FT CREEK BUFFER 702 PROPOSED GRADE PIPE SCHEDULE: PIPE P1 = 24" CLASS III, RCP ACCESS AND MAINTENANCE INLET INV. ELEV. = 501.73 FT OUTLET INV. ELEV 500.00T� EASEMENT (TO BE RECORDED) MONISM mmom% ,' LENGTH = 94.50 FT WALLACE� - - - % / < �,• 60 MAINTENANCE R/W) 0-10/ r .� �' PIPE P2 = 24" CLASS III, RCP 502 -P �� OUTLE V. ELEV. =4�6.7 FT 504 - - EN - / 1` 74.00 ,iT 504 / Ss E _ 10 / 8 0 p2 ES-2CD o� _�p 1 �o 11� 41 / r I 500 Q oQ h G�GEL -STORAGE�LOT / , ^G ti 111426 AZ�QO a (2.55 ACRES 506 I/ Cam`�� GRAPHIC SCALE 40 0 20 ao 80 / �`' / / � ••• � / ��� / i/ I ANTYE�. _ /OFF SITE BORROW ANP WASTE REQUIRED FOR THIS PROJECT MUST COME FROM A'SITE N e06Rn1Fn CRnCIMJ rnu AN - I mi C.-ry o� •u � c,orrv„ .��nre ., d 'Yi is -IQ 7C1/ ANCJS 'AiIV--iii, C `t(;)_K:IUV G3 ,J:;- 0- 1- s x;cJLN-V 1, (;i A) X I c'c ci )- -I i;v:; IG 1- s REFERENCE: ALL PARCEL AND BOUNDARY INFORMATION FOR - ;Ju vl, v P-c - c� v 'A31, /� I-{;JI Hi 11-14 CGAS VI ADJACENT PROPERTIES, PROPERTY DIMENSIONS, AND COORIDIN) ANCJS 'A-<N-is, :i :n_�C I -I I-) GV r CABARRUS COUNTY GIS. _?Cm I- Gi t: VA t:- I- :; )CC,1N- V I, A_: A "t{:V- 1 i Y d- CC i-1-) R; 3- VA ), Il.)- CC'-[; Firm License # P-1191 7140 Weddington Road Suite 140 Concord, NC 28027 Civil Site Design Low Impact Development Small -Scale Building Design Telephone: 704.573.1621 Facsimile: 704.248.7951 Seals: SEAL 9r; 032006 %ty 4;G.INS�-L Jr. O �<z �-- > - < J >}-- z � Q Q �Q z Q z =o z Project Number: 17.16.138 Date: 02/04/2019 Drawn By CMM Checked By NRP RCV151on5: 1 2/14/17 ORIGINAL SUBMITTAL 07/ 10/ 18 PER NCDEQ 09/ 13/ 18 PER NCDEQ 02/04/ 19 PER NCDEQ Sheet Title: GRADING PLAN Sheet No: C�5m UNDERDRAIN SYS. (TYP.) THE TOP OF THE SAND FILTER MEDIA MUST BE PROTECTED. CLEAN WASHED 6" SCH. 40 PVC STONE MUST BE USED TO PREVENT LARGE L"TA B�.E S••�R 00—Ct"G GIT STEM . nllr MONO mow loom NONE / CLEANOUT (TYP.) / WALLACE___ - - 1-1 r 60' MAINTENANCE R W) -€x-f 72"CIVIP INV-493.62' 504 \f RIP RAP BERM SEDIMENT FOREBAY FB-1 SAND FILTER SF-1 (SEE DETAIL ON THIS SHEET) SIDE SLOPES OF SF AREA TO BE 3:1 AND MUST BE SODDED TO PREVENT CONTAMINATION OF SAND IN FILTER 510 50C DATU.Y ELEV 490 10—YR, 24—HR WAT 1— YR, 1ST WASHED SAND BASE BERMUDA SOD OR A HARD SURFACE SUCH AS RIVER ROCK GEOTEXTILE FABRIC OR CHOKER COURSE DO NOT COMPACT BOTTOM SCARIFY BOTTOM A MINIMUM OF 3—FEET TYPICAL SECTION NOT TO SCALE 18" TOTAL SAND 12" OVER UNDERDRAIN PERFORATED PIPE UNDERDRAIN COLLECTION SYSTEM THE UNDERDRAIN COLLECTION SYSTEM SHOULD BE EQUIPPED WITH 6—INCH MINIMUM PERFORATED SCHEDULE 40 OR STRONGER PVC PIPE.PERFORATIONS SHALL BE PER AASHTO M278 FOR PVC PIPE,OR BE 3/8—INCH IN DIAMETER SPACED 3 INCHES ON CENTER ALONG 4 LONGITUDINAL ROWS THAT ARE SPACED 90' APART. THE PIPES SHALL HAVE A MINIMUM SLOPE OF 0.5% AND A MAXIMUM SPACING OF 10 FEET ON CENTER. SAND FILTRATION DETAIL REF: CHARLOTTE—MECKLENBURG BMP DESIGN MANUAL (REVISED JULY 2013) 1 SAND FILTERS SF-1 PLAN VIEW 5.2 THE TOP OF THE SAND FILTER MEDIA MUST BE PROTECTED. CLEANOUTS OF 6-INCH SOLID PVC MUST BE PROVIDED FOR EVERY 50 LINEAR FEET OF UNDERDRAIN, AT ALL BENDS, AND CLEAN WASHED STONE MUST BE USED TO PREVENT LARGE ENDS OF THE SYSTEM FOR MAINTENANCE PURPOSES. THE TOP OF THE CLEANOUTS SHOULD EXTEND 6 INCHES ABOVE THE TOP FLOATABLES FROM CLOGGING THE SYSTEM. OF FILTER AND HAVE A WATERTIGHT, VANDAL PROOF CAP. AT LEAST ONE CLEANOUT SHALL BE INSTALLED AS AN EMERGENCY DRAIN THAT IS FLUSH WITH THE TOP OF FILTER AND HAVE A 6-INCH THREADED EXTENSION PIPE. THE FURTHEST CLEANOUT FROM THE OUTLET MUST HAVE THE MINIMUM REQUIRED FILTER MEDIA DEPTH. TOP OF RISER EL EV. = 502 40 F T CONCRETE RISER STRUCTURE 50-YR, 24-1-IR WATER SURFACE ELEVATION = 503,48 FT WITH 6" THICK 3,50E PSI PRE -CAST CONCRETE RISER WALL (SEE DETAIL ON THIS SHEET) CONSTRUCTION GUIDELINES FOR SAND FILTRATION BASIN SPEC IFICATION/TEST METHOD SIZE NOTES MATERIAL Sand substitutions such as Diabase and Graystone #10 are not acceptable. No ASTM-C-144 or 0.02" to 0.04" calcium or dolomitic sand substitutions are ASTM-C-33 concrete sand acceptable. No "rock dust" can be used for Sand sand. Ash content < 15%, The material must be reed -sedge humic peat, pH range: 5.2 to 4.9, n/a shredded, uncompacted, uniform and clean. Loose bulk density (For open and sand filter only). Peat Underlain Gravel blue stone, double washed, #57 stone 0.5" to 1.5" 4" min. over underdrain and max of 12" total Must maintain 125 gpm/ft"2 flow rate. Note: a Geotextile Fabric MIRAFI 140 OR EQUAL 0.08" thick 4" pea gravel layer may be substituted for (if required) equivalent opening g eotextiles meant to "separate" sand filter size of #80 sieve layers. ASTM-D-4833 (Thickness) ASTM-D-412 (Tensile strength 1,100 lb, Liner to be ultraviolet -resistant. A geotextile Impermeable Liner elongation 200 percent) 30 mil thickness fabric should be used to protect the liner from ASTM-D-624 (tear resistance - 150 lb/in) puncture. ASTM-D-471 (water absorption: +8 to 2% mass) Min. 6" perforated Scheduled 40 3/8" perf. @ 3" O/C along 4 longitudinal rows that are Underlain Piping AASHTO-M-278 (PVC) or stronger PVC or double spaced 90 degrees apart. Pipes shall have a min. slope AASHTO-M-252 (HDPE) wall HDPE of 0%and max spacing of 10' O.C. On -site testing of poured -in -place concrete required: 28-day strength and slump test; all Concrete (cast-in- Fe=3,500 psi; normal weight, concrete design (cast -in -place or pre -cast) not air -entrained; reinforced to meet ASTM-615-69 n/a using previously approved state or local place) standards requires design drawings sealed and approved by a licensed, professional structural engineer. Concrete (pre -cast) Per pre -cast concrete manafacturer n/a Non-rebar steel ASTM A-36 n/a REFERENCES: MANUAL OF 5TOKMWATER BE5T MANAGEMENT PRACTICE5; NORTH CAKULINA uCrAKt MCNI VI- CNVIKVNMGNI ANU NAI UKAL KC UUKU. TOWN OF HUNTER5VILLE WATER QUALITY DE51GN MANUAL (JUNE 2013 EDITION) CHARLOTTE-MECKLENBURG BMP DESIGN MANUAL (REVISED JULY 201 3) ADMIN15TPATION MANUAL FOR IMPLEMENTATION OF THE P05T-CONSTRUCTION STORM WATER ORDINANCE (REVISED JUNE 201 3) SAND FILTER MAINTENANCE TA5K5 AND SCHEDULE FES-2 -- — ,P OF EN" I 0MEN FT 5 - -- ---- --- — — ---- - - ----- — 1—_- - - n - III y F - - ---- -I -I r �-4-__--,----+I-1 I_ --_�--- �I�-1�-1��7. _-_ _ —_- - ------ - I=—=H I� R SURFACE EL EVATIUN = 502,91FT 0 115E 4-HR WATER SURFACE EL EVAI-ION = 5 .66F CH WA TER SURFACE EL EVA TION = 501, RIPR 5 FT P BERM 2 0 0 0+00 THE UNDERDRAIN COLLECTION SYSTEM SHOULD BE EQUIPPED 1 +00 WITH 6-INCH MINIMUM PERFORATED SCHEDULE 40 OR STRONGER PVC PIPE. DO NOT COMPACT BOTTOM PERFORATIONS SHALL BE PER AASHTO M278 FOR PVC PIPE, AASHTO M252 SCARIFY BOTTOM PRIOR TO THE PIPES SHALL HAVE A MINIMUM SLOPE UNDERDRAIN INSTALLATION OF 0.5% AND A MAXIMUM SPACING OF 10 FEET ON CENTER. 1 +5U _.. J_ 14� ...I v V V 10, 1I v 11 4_ SAND FILTERS SF-1 PROFILE VIEW WATERTIGHT JOINT AT RISER CONNECTION 1 INCH = 10 FEET 10 0 5 10 20 24 REINFORCED CONCRETE PIPE (TO FES-2 INLET INVERT ELEV. = 497.5 FT OUTLET INVERT ELEV. = 496.75 FT LENGTH = 74.00 FT .. SLQPE y,1.01 i VERTICAL GRAPHIC SCALE (PROFILE VIEW) 1 INCH = 10 FEET 10 0 5 10 20 GRAPHIC SCALE (PLAN VIEW) 30 0 15 30 60 COPYRIGHT© 2017 AMICUS PARTNERS, PLLC. ALL RIGHTS RESERVED. REPRODUCTION OR USE OF THE CONTENTS OF THIS DOCUMENT, OR ADDITIONS OR DELETIONS TO THIS REFERENCE: ALL PARCEL AND BOUNDARY INFORMATION FOR THIS PROPERTY AND DOCUMENT, IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT ADJACENT PROPERTIES, PROPERTY DIMENSIONS, AND COORDINATES REFERENCED FROM OF AMICUS PARTNERS, IS STRICTLY PROHIBITED. ONLY CABARRUS COUNTY GIS. COPIES FROM THE ORIGINAL OF THIS DOCUMENT, AS APPROVED BY 'HE ENGINEER SHALL BE CONSIDERED TO BE VALID, TRUE COPIES. TRASH RACK NOTES: EACH TRASH RACK IS TO BE CONSTRUCTED OF #3 REBAR, MUST BE GALVANIZED PRIOR TO FINAL ASSEMBLY. OPENINGS ARE TO BE NO MORE THAN 6" SQUARE. THE ORIFICE TRASH RACKS ARE TO BE ASSEMBLED IN ONE PIECE, AND THE TOP TRASH RACK IS TO BE ASSEMBLED IN 4 SEPARATE PIECES AND BOLTED (NOT WELDED) FOR FINAL ASSEMBLY. TRASH RACK SHALL HAVE A HINGED PANEL FOR WORKER ACCESS. (SEE ABOVE DETAIL) TOP VIEW 24" REINFORCED CONCRETE PIPE (TO FES-2) INLET INVERT ELEV. = 497.5 FT OUTLET INVERT ELEV. = 496.75 FT LENGTH = 74.00 FT SLOPE = 1.01 % f 4.0 FT f TASK SCHEDULE INSPECT BANKS AND SURROUNDING DRAINAGE AREAS FOR EROSION AND STABILIZE IF NECESSARY MONTHLY STREET SWEEP PARKING LOT QUARTERLY TRASH REMOVAL MONTHLY INSPECT OUTLET FOR OBSTRUCTIONS MONTHLY INSPECT FOR CLOGGING MONTHLY INSPECT INLET GRATES MONTHLY SKIM SAND MEDIA YEARLY PUMP OIL AND GRIT FROM SEDIMENTATION CHAMBER YEARLY OR AT 50% FULL REPLACE SAND MEDIA AS NEEDED (EXPECT 3 YEARS) GRA55ED SAND FILTER MOW BASIN TO RECOMMENDED HEIGHT IN ALTERNATING PATTERNS TO PREVENT COMPACTION AND PREVENT WEED GROWTH. BAG CLIPPINGS TO PREVENT THATCH BUILT-UP. WEEKLY TO BI-WEEKLY DURING THE GROWIN SEASON, AS NEEDED OTHER SEASONS LIGHT FERTILIZING TO ESTABLISH HEALTHY ROOTS ONLY DURING THE FIRST 2 YEARS AERATE AND DETHATCH BASIN FLOOR EVERY 2 YEARS NOTE: NO SOD/GRASS IS TO BE PLACED ON TOP OF SAND FILTER. REFERENCE TO GRASS MAINTENANCE IS FOR ALL AREAS OUTSIDE THE SAND FILTER. SAND FILTER TO BE PROTECTED WITH A CLEAN, WASHED STONE ON TOP OF SAND. 510 DATUM ELEV 490 4'X4' REINFORCED CONCRETE RISER (INTERIOR DIMENSIONS) HARD PIPE TO UNDERDRAIN COLLECTION SYSTEM RISER STRUCTURE DETAIL 5.2 SCALE: N.T.S. RACK IGLE 8" ORIFICE ` VATION @ CENTER OF ORIFICE = 501.50-FT /) 15 REBAR MAT @ 12" ON CENTER \1 EACH DIRECTION DNCRETE PIPE _AVING THE RISER UST BE 0-RING PIPE 6' X 6' X 1.0' 3,500 PSI CONCRETE SPREAD FOOTING WITH (2) REBAR MATS CONSISTING OF #6 REBAR 12" ON CENTER IN EACH DIRECTION Firm License # P-1191 7140 Weddington Road Suite 140 Concord, NC 28027 Civil Site Design Low Impact Development Small —Scale Building Design Telephone: 704.573.1621 Facsimile: 704.248.7951 Seals: r SEALS' • 032006 01.oy.7al.1 lI i 41�--I Z �QO � Z L L L > o Z L--� Q T_ d �o Project Number: 17.16.138 Date: A02/04/2019 Drawn By. CMM Checked By. NRP Rev151on5: 1 2/ 1 4/ 1 7 ORIGINAL SUBMITTAL 0711 0/ 18 PER NCDEQ 03/ 1 3/ 1 8 PER NCDEQ I I /2G/ 18 PER NCDEQ 02/04/191 PER NCDEQ Sheet Title: SAND FILTER SF-1 PLAN AND DETAILS Sheet No: C�502 I . UNIFORMLY GRADE A SHALLOW DEPRESSION APPROACHING THE INLET. 2. DRIVE 5-FOOT STEEL POSTS 2 FEET INTO THE GROUND SURROUNDING 1) GROUND STABILIZATION• PLAN I A t`1 VIEW CIA! THE INLET. SPACE POSTS EVENLY AROUND THE PERIMETER OF THE L A V V E YV INLET, A MAXIMUM OF 4 FEET APART. SKIMMER SEDIMENT BASIN DESIGN CRITERIA 3, SURROUND THE POSTS WITH WIRE MESH HARDWARE CLOTH. SECURE THE SITE AREA STABILIZATION TIME STABILIZATION TIME WIRE MESH TO THE STEEL POSTS AT THE TOP, MIDDLE AND BOTTOM. DESCRIPTION FRAME FRAME EXCEPTIONS PLACING A 2-FOOT FLAP F THE WIRE MESH UNDER THE GRAVEL FOR ANCHORING IS RECOMMENDED. DRAINAGE PERIMETER DIKES, AREA < 10 AC. 4. PLACE CLEAN GRAVEL (NC DOT #5 OR f57 STONE) ON A 2:1 SLOPE GENERAL NOTES: SWALES, DITCHES 7 DAYS NONE MBANKMENT WITH A HEIGHT OF 16 INCHES AROUND THE WIRE AND SMOOTH TO AN (ACRES) LENGTH EVEN GRADE AND SLOPES 1. A STABILIZED ENTRANCE PAD OF #5 WASHED STONE OR RAIL ROAD BALLAST SHALL BE LOCATED WHERE TRAFFIC ._. - 5. ONCE THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE WILL ENTER OR LEAVE THE CONSTRUCTION SITE ONTO A PUBLIC STREET.HIGH QUALITY 7 DAYS ACCUMULATED SEDIMENT AND ESTABLISH FINAL GRADING ELEVATIONS.WATER (HQW) NONE MIN. INFLOW LENGTH TO 2:1 ST6. COMPACT THE AREA PROPERLY AND STABILIZE IT WITH GROUNDCOVER. 2. FILTER FABRIC OR COMPACTED CRUSHER RUN STONE SHALL BE USED AS A BASE FOR THE CONSTRUCTION ZONES RUCTURE WIDTH RATIO 10' ENTRANCE. MIN. IF SLOPES ARE 10' OR Amicus Partners, PLLC NOTES: 3. THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING OF SEDIMENT SLOPES 3:1 OR 7 DAYS LESS IN LENGTH AND ARE ONTO PUBLIC STREETS OR EXISTING PAVEMENT. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL FLATTER NOT STEEPER THAN 2:1, 14 MAX. LENGTH TO 6:1 STONE AS CONDITIONS WARRANT AND REPAIR OR CLEANOUT OF ANY MEASURES USED TO TRAP SEDIMENT. DAYS ARE ALLOWED. WIDTH RATIO 1. REFER TO SKIMMER NCESCPDM 4, ANY SEDIMENT SPILLED, DROPPED, WASHED, OR TRACKED ONTO PUBLIC STREETS MUST BE REMOVED IMMEDIATELY. 7-DAYS FOR SLOPES DEWATERING SECTION #6.64 - He DOT #s OR /57 SLOPES 3:1 OR 14 DAYS GREATER THAN 50 FEET IN MIN. 1800 AVERAGE = ARE`` DEVICE FOR ADDITIONAL WASHED STONE 5. WHEN APPROPRIATE, WHEELS MUST BE CLEANED TO REMOVE SEDIMENT PRIOR TO ENTERING A PUBLIC STREET. WHEN FLATTER LENGTH Firm License # P-1191 VOLUME PER C. WIDTH LENGTH DESIGN WASHING IS REQUIRED, IT SHALL BE DONE IN AN AREA STABILIZED WITH CRUSHED STONE WHICH DRAINS INTO AN SPECIFICATIONS ALL OTHER AREAS NONE (EXCEPT FOR g REQUIRED PER AC. MERGENCY APPROVED SEDIMENT BASIN. SEE STD. N0. 515.1. WITH SLOPES 14 DAYS PERIMETERS AND HOW 7140 Wsdde 140 Road DISTURBED) AREA OF BASIN WATER SPILLWAY REGARDING 6. TOWN MAY REQUIRE A STANDARD COMMERCIAL DRIVEWAY TO ACCESS THE CONSTRUCTION SITE IF THE DRIVEWAY IS FLATTER THAN 4:1 ZONES) SURFACE AT TOP OF _.- ; ` .. SKIMMER SEDIMENT SURFACE ON A THOROUGHFARE. Concord, NC 28027 325 PRIMARY SPILLWAY BASINS. *"EXTENSIONS OF TIME MAY BE APPROVED BY THE PERMITTING (Sq• FT_ AREA 19-GUAGE HARDWARE CLOTH ---.- 4' MAX­UTHORITY BASED ON WEATHER OR OTHER SITE -SPECIFIC Civil VI I Site Design s i n PER CFS 2. REFER TO STD. g REQUIRED Q10) (1/4 INCH MESH OPENINGS) 100 FT (MIN) CONDITIONS THAT MAKE COMPLIANCE IMPRACTICABLE." (SECTION - CROSS-SECTION VIEW BAFFLES #524.1 FOR - II.8(2)(b)) Low Impact Development BAFFLE SPACING - - P P 1' FREEBOARD W=5' MIN. AND INSTALLATION. I REFERENCE: NORTH CAROLINA DIVISION OF WATER QUALITY I -I 6" MAX. DEPTH OF FLOW OVER MBANKMENT EXISTING GROUND -I I l I I-1 I I -Ili (DWQ) CONSTRUCTION GENERAL PERMIT (NCG01) Small -Scale Building Design INFLOW EMERGENCY SPILLWAY - STRUCTURE 11=1 I I -III -I I -I 11=1 I -I 11-1 I I-III-1 11=I I' STRUCTURE BAFFLES T=1.5' MIN. WOVEN GEOTEXTILE Telephone: 704.573.1621 MIN. I' 3' 2' EQUIVALENT TO MIRAFI 50OX #5 WASHED STONE X P Z=5' MAX. j j TEMPORARY SILT DITCH < Facsimile: 704.248.7951 1 1 SEE DETAIL STD. 30.05 1 OR FLATTER DEWATERING I - - INC DOT OR ONE #57 100 FT (MIN) SEE NOTE 2 0 WASHED ZON H=2 MIN. MERGENCY 1� " Seals: FILTER FABRIC SPILLWAY L m SEDIMENT LA3 GD 10' CONSTRUCTION �l NOT TO SCALE ANTI -SEEP tr-i STORAGE ZONE COLLAR v (n ACCESS FIWATER 2' TEMPORARY 1 OR FLATTER i~C ����js,✓Q/''i���,„ SILT FENCE 2 SKIMMER SEDIMENT TRAP DATA BLOCK 7SEE DETAIL SEAL SKIMMER GOVERNING DRAINAGE DENUDED BASIN VOLUME BASIN SURFACE AREA CLEANOUT H Z L T W SKIMMER SKIMMER SKIMMER STD. 508.1 0 . o TRAP PHASE AREA AREA Q10 REQUIRED PROVIDED REQUIRED PROVIDED DEPTH (FT.) (FEET) (FEET) (FEET) (FEET) (FEET) PIPE ORIFICE ORIFICE 2-3 INCH COARSE AGGREGA WIRE MESH ® 032006 s (ACRES) (ACRES) (CUBIC REQUIRED (CUBIC FT.) (SO Fi. (SO Fi. H/2 DIAMETER DIAMETER RADIUS ��� � � :01-����� SST-1 PHASE I 1.10 2.86 5.91 1,980 16,830 1,921 4,571 1.00 2.0 4.0 18.0 2.5 8.0 3.0" 2.8" 1.4" ' r e u SST-2 PHASE II 2.81 3.47 17.34 5,085 27,577 5,635 7,377 1.00 2.0 4.0 16.0 1.5 8.0 4.0" 3.3" 1.7 f ' 1 Hardware Cloth & Gravel Inlet Protection Detail 4�s�`AS �,?w^�� f ' �+lt it 111, �Ti 6.o Ref: NCDENR 3 Construction Entrance Detail I 2 FT (MIN) •Z•oY• ZOi9 1 Skimmer Sediment Trap Detail 6.0 � Slope Stability Ref: NCDENR #6.06.1 6.0 Ref: NCDENR #6.64.7 60 Ref: MCLDS Standard #30.16 NOTES: - oFL SURFACE AREA 1. A MINIMUM OF 24" FROM OUTSIDE DIAMETER OF PIPE TO SIDE INLET DONE 25% 0 SU FACE AREAENTRY WATER ENTRY UNIT OF TRENCH MUST BE ALLOWED FOR COMPACTION OF FILL WITTRASHSCREEUNIT WITH TRASH SCREEN GENERAL NOTES: IN ZONE 25% GENERAL NOTES: WITH TRASH SCREEN GENERAL NOTES: PROPER DESIGN MUST BE COMPLETED TO MINIMIZE PIPING AROUND DISCHARGE PIPE. MATERIAL. BACKFILLING OF TRENCHES SHALL BE ACCOMPLISHED OF SURFACE AREA 1. PROPER DESIGN MUST BE COMPLETED TO MINIMIZE PIPING AROUND DISCHARGE PIPE. .02. PROPER ORIFIC AER THE PIPE IS LAID. THE FILL AROUND THE E OPENING MUST BE SELECTED TO ENSURE POND DRAINS INCORRECT 1. DRIVE 5' STEEL POST AT LEAST 2. PROPER ORIFICE OPENING MUST BE SELECTED ENSURE POND DRAINS IN CORRECTIMMEDIATELY AMOUNT OF TIME. MODIFICATIONS MAYBE REQUIRED IF FIELD CONDITIONS WARRANT A O SURFACE AREA AMOUNT OF TIME. MODIFICATIONS MAY BE REQUIRED IF FIELD CONDITIONS WARRANT A CHANGE. /y UTLET ZONE 1 %A 24" INTO SOLID GROUND. CHANGE, 3. EMBANKMENT MUST BE COMPACTED TO DESIGN SPECIFICATIONS. 3. EMBANKMENT MUST BE COMPACTED TO DESIGN SPECIFICATIONS. PIPE SHALL BE PLACED IN LAYERS NOT TO EXCEED 6". QF 4. EMERGENCY SPILLWAY MUST BE CORRECTLY SIZED AND EROSION PROTECTION INSTALLED. 4. EMERGENCY SPILLWAY MUST BE CORRECTLY ALONG THE EROSION PROTECTION INSTALLED. UNDER NO CIRCUMSTANCES SHALL WATER BE PERMITTED 2. USE STAPLES 1' APART S. EROSION PROTECTION MUST BE INSTALLED ALONG THE EMBANKMENT AND AT THE / \ HORIZONTALLY AND VERTICALLY 5. EROSION PROTECTION MUST BE INSTALLED ALONG THE EMBANKMENT AND A7 THE DISCHARGE END OF THE PIPE. \\JJ TO RISE IN UNBACKFILLED TRENCHES AFTER THE PIPE HAS BEEN ORIFICE OPENING INSIDE THE DISCHARGE END OF THE PIPE. ORIFICE OPENING INSIDE THE 6. INSPECT SYSTEM REGULARLY TO ENSURE IT IS FUNCTIONING IN A CORRECT MANNER. TO ATTACH THE POROUS 6. INSPECT SYSTEM REGULARLY TO ENSURE IT IS FUNCTIONING IN A CORRECT MANNER. ORIZONTAL TUBE IMTH A ORIZONTAL TUBE WITH A CONSTANT HYDRAULIC HEAD 7. EIGHT SIZES OF SKIMMERS ARE AVAILABLE, REFER TO THE FLOW SHEET, CUT SHEET, AND PLACED. COMPACTION REQUIREMENTS SHALL BE ATTAINED BY FCQ� I BAFFLES TO THE WIRE FENCE. CONSTANT HYDRAULIC HEAD T EIGHT SIZES OF SKIMMERS ARE AVAILABLE. REFER TO THE FLOW SHEET, CUT SHEET, AND NSTRUCT ONS ON WEB SITE FOR EACH SIZE. \_ IN ON WEB SITE FOR EACH SIZE. THE USE OF MECHANICAL TAMPS ONLY. EACH AND EVERY LAYER � X 3. MINIMUM BAFFLE SPACING IS 10'. OF BACKFILL SHALL BE PLACED LOOSE AND THOROUGHLY COMPACTED � � 1 SCHEDULE 40 PVC PIPE INTO PLACE. 4. THE FLOOR OF THE BASIN IN SCHEDULE 40 PVC PIPE BARREL OR ARM) THE OUTLET ZONE AND BERMS (BARRELORARM) RTHEN EMBANKMENT 2 FLOW h MAXIMUM HEIGHT OF FLOAT WHEN NO OTHER < ALL BACKFILL MATERIAL SHALL HAVE AN IN PLACE COMPACTED DENSITY OF 95%. �- \ X SHOULD BE SEEDED IMMEDIATELY MERGENCY SPILLWAY AFTER THE BASIN IS TORM WATER DISCHARGE OPENINGS EXIST "Y' •' (MAJOR STORM EVENT) LEXIBLE HOSE ARTHEN EMBANKMENT `-•� 3. STANDARD PROCTOR. THE FINAL 2' BELOW FINISHED GRADE SHALL BE 100%. c CONSTRUCTED. LEXIBLE HOSE FLOAT 4. ALL TRENCHING OPERATIONS SHALL MEET OSHA STANDARDS. / FLOAT MERGENCY SPILLWAY PVC VENT O 5. REFER TO NCESCPDM SE TION PIPE 5. BACKFILL MATERIAL BENEATH ROADWAY SHALL BE SELECT BACKFILL MATERIAL. / EyRr S#6.65PECI FOR ADDITIONAL INVERT OF LOWEST STORM WATER PVC VENT ^ ^ l / N X SPECIfIATIONS. GRATE,. ISCHARGEOPENING PIPE Lam. t� / BERM (MINOR STORM EVENT) / TOP VIEW LOAT TOP VIEW SCHEDULE 40 PVC PIPE COAT FLEXIBLE HOSE MUST BE (BARREL OR ARM) � ^ i0 SECURELY FASTENED TO THE VC VENT PIPE / e VC VENT PIPE STORM WATER WATER QUALITY DISCHARGE FLEXIBLE HOS 1 ! 1 O OVr� OPENING DISCHARGE OPENING V J Q O O/III �7 TCif OUTLET PIP z O POTENTIAL FOR AN PROPER DESIGNTO MINIMIZE DISCHARGE AROUND L x LEXIBLE HOSE PIPE MUST OCCUR. O `� Q OUTSIDE DIAMETER \ X X ATER ENTRY UNIT ATER ENTRY UNIT < Z SCHEDULE 40 PVC PIPE �, / < ^ (BARREL OR ARM) 1 V IL---1\ 4'-0" MAX. SPACING 1 5' STEEL POST END VIEW MAINTAIN DEPRESSION TO END VIEW SIDE VIEW MAINTAINDEPRESSIONTO DISCHARGE PIPE SIDE VIEW VARIES (TYPICAL) MINIMIZE CHANCE OF SKIMMER ROUS MATERIAL (15" MIN) COMBINED JUTE MESH ( ) MINIMIZE C BECOMING STUCK SCHEDULE 40 NO SCALE ( FLOW NO SCALE 1 ) BECOMING STUCK i DRAWN ev T. R EVAHs 1a10 n AND NAG C 125 ^ o DRAWN DY T. R. EVANS IUIO LL- 24" 4 J. W FNRCLOTH I SON INC COCONUT LINER OR ® W AIRCARCL OTHISONINC. FAIRCLOTH SKIMMER DISCHARGE SYSTEM WITH EMBANKMENT EQUNALENn. 8" X 6" TRENCH M WANJ TELEPHONE, HSK MMER COM W TELEPHONE (919) 7n-124CdOM I BACKFILL AND FAIRCLOTH SKIMMER DISCHARGE SYSTEM WITH OUTLET STRUCTURE TEL FAk(91: (919-12662M FA (919)T321266 Z TEN (919) CLOT 66 PIPE SHALL BE PLACED EMAIL WARREN0FA RCLOTHS MMERCOM COMPACT FENCE AND EMAIL: WARRENOFAIRCLOTHSNIMMER.COM ON SUITABLE MATERIAL FABRIC BURIED IN TRENCH (-2 Faircloth Skimmer Detail 0 5 Trench Detail for Storm Drain -� II�� 6.0 Ref: Faircloth skim mer.com 6.o Ref: MCLDS Standard #20.25 Baffle Installation Detail _�� 6.0 Ref: MCLDS Standard #30.19 NOTES: END OF FLARED SECTION 0 1. CLASS OR MEDIAN SIZE OF RIPRAP AND LENGTH, WIDTH AND DEPTH OF APRON oy s oN om a TO BE DESIGNED BY THE ENGINEER. C:S. Y bo13w T��-�r"I- 48"R ,a=.¢r'v any$ az 2. REFER TO THE CHARLOTTE MECKLENBURG STORM WATER DESIGN MANUAL FOR C RIPRAP APRON DESIGN STANDARDS. �i �DlD'm .E'i w¢yLL ^2ySp Owoa=z 3. RIPRAP SHOULD EXTEND UP BOTH SIDES OF THE APRON AND AROUND THE END �x s a " m X X i=am OF THE PIPE OR CULVERT AT THE DISCHARGE OUTLET AT A MAXIMUM SLOPE OF y g L u�,, , =��K nos ' GENERA 40TE5: cn +i .2-+ 2:1 AND A HEIGHT NOT LESS THAN TWO THIRDS THE PIPE DIAMETER OR Project Number: 17.16.138 _>n cc[n¢ CULVERT HEIGHT. yo �,- ."" USE STANDARD OR UUY[K) BRICK F3R WAL. CONSTRUCTION. SOLID •4 z MOLILIL.] ��' w0 CONCRETE BRICK OR D:.00K ARE OPTIONA_ NAL_ CON9IRUCIION MAIERIAL BILL OF MATERIAL a^" x Y "*1104 w� 4. THERE SHALL BE NO OVERFLOW FROM THE END OF THE APRON TO THE ���,, L' PLAN PRECAST UNITS MAOF OF CLASS "AA" CONCRFTF MAY RF USFD IN LIEU a •� �r , N , c SURFACE OF THE RECEIVING CHANNEL. THE AREA TO BE PAVED OR RIPRAPPED Date: 14- � 02/04/2019 ."loNA: MAYHO_L �I OF BRICK MASONRY CONTRUCTION. SUBMIT OFSTGN QE PRFCAST UNITS B +4 .6 6's• eR..• 1 1 SHALL BE UNDERCUT SO THAT THE INVERT OF THE APRON SHALL BE AT THE ^tt u'ENIW4 NaiEfi 8'�8- (WITHOUT TOPI FOR APPROVAL PPIDR TO CONSTRUCTION. t 2E .a +'-a' 2a , "f ' 1%FOWI AN /j -- SAME GRADE (FLUSH) WITH THE SURFACE OF THE RECEIVING CHANNEL. THE SrEF., thFOBAATifri !' )' BTE 9TANDA4I1 B+a.54 14 ES 1C1.S I 1 EaR YAN,-0th 1:'J'JEN A ,FN2 1NCLUOE ALL PRICETBID F i0 MALLS, B:.A85 UR REINFORCING W1IERIAL B B Drawn BY: CMM 'i a.a• HUOK� ?'�' RADIUS J X tN THE UNIT PRICE BID FOR EACH UNIT. luLL TOTAL 11L21N1 21., z 2 2 APRON SHALL HAVE A CUTOFF OR TOE WALL AT THE DOWNSTREAM END. "o T.i5U IAY eL O6L0 Ic O 1 co Yw. cLA6B 'A. caAc s.a K 5. THE WIDTH OF THE END OF THE APRON SHALL BE EQUAL TO THE BOTTOM x m PLAN OF TOP SLAB FINIS" GBAOL DJUST FRIIF A :arse Ip w T1 INSTALL OPTIONAL MANHOLE IN POSITION AS DIRECTED BY THr ENGINEER. q q S .•: to gusFAtF FIEv4t;OY w[ ,' ¢ O o CUT OR BrNG At., RFRAR CROSSING; THIS DPFNTNO TO ALLOW 2' MINT eU. •:%. W1[CIGi TT. NT. 9' a.aO w uYrr 9AR8 TANCRETT *OP STAB c Z Z = T m CONCRETE COVERAGE. ENCLOSE THE OPENING WITH 8 "A" BARS TIED i0 tU. YOa. tlRICK rt. NT. f aj a.we. 2 m � m n .rr B' t CT fi" LIAR DIMENSIONS ARE .1 10 out 'B' Bags a O = C T TO THE REBAR MAT AND SET 50 A MINIMUM or D' CONCRETE COVER IS o z WIDTH OF THE RECEIVING CHANNEL. MAXIMUM TAPER TO RECEIVING CHANNEL 5:1 O I Y o Ey C5 m M ATTAINED. REFERENCE 9TD. N0. 840.54 FOR MANHOLE IN."DRMATION. ------ w o Checked By. NRP ¢ (n �c I- 0 6. ALL SUBGRADE FOR STRUCTURE TO BE COMPACTED TO 95% OR GREATER. -i M Gn p 3 V f tox PROVIDE UUNCTION BOXES WITH MAHNO.ES OVER 3•-6" IN DEPTH KITH ¢ T a --I y.;• Z STEPS PLACro ON 12" CENTERS. RErERFMC,E STD. NO. 840.66. 3 9 m _� O _ ¢ z " = I I 7. THE PLACING OF FILL, EITHER LOOSE OR COMPACTED IN THE RECEIVING N o S D•• -_._L ' B ¢ 2 aw. _ > MAXIMUM DEPTHCOFBTHISAUN11 ASIM F112' 2CENIENB. CD m END OF APRON •� CHANNEL SHALL NOT BE ALLOWED. Revlslons: p L ' '� 6" S ~ 6. (mj) O CONSTRUCT THE JUNCTION PDX IN ACCORDANCE WITH < z ii 8. NO BENDS OR CURVES IN THE HORIZONTAL ALIGNMENT OF THE APRON 2/ 14/ 17 ORIGINAL SUBMITTAL N = I i yLSTEPa &C Q L SECTIONS 830, $32, 834 AND 840 OF THE STANDARD SPECIFICATIONS. ED N a WILL BE PERMITTED. = D :� AFNEAAL WEB W = A occ m N y n y PLAN 02/04/ 19 PER NCDEQ o H c+ n £ = m s 9. FILTER FABRIC SHALL BE INSTALLED ON COMPACTED SUBGRADE PRIOR TO . 12" YIYtS iH3M z c Z s xt IN6LI "A- ,OY It_uS1HAl:or -J M ? v ►+ Ci „N., V w PLACEMENT OF RIP RAP. = a eoAEl .o., nw.'oses CNI r ` O J ~ ITT INSET „A„ xE WTE L. - w LL z = O r n CU � 10. ANY DISTURBED AREA FROM END OF APRON TO RECIEVING CHANNEL k PLAN OF BOTTOM sk" CONCRETE BLOCK u. s a o - 0 R SLOPE -APRONS MUST BE FLAT MUST BE STABILIZED. NOTE 1: CONSTRUCT SECTION "B" OF THE PROPOSFD WALL 8" THICKK F NOTE 2: IF PROPOSED STRUCTURENEXCEEDS 17'-0" VERTICAL HEIGHT A -1 USE USDA NOMOGRAPH FROM NC SEDIMENT AND EROSION CONTROL MANUAL OR DESIGN WILL BE REOUIREDINFORC NGR APPRCVAL. 1' MIN. CHARLOTTE MECKLENBURG STORM WATER DESIGN MANUAL FOR DESIGN DATA. NOTE 3: USE S11K.Lf MAI REINFORCING STEEL; `r" Mrns 11L4^ ^HILL + 1' MIN.map ULLI + Or " EXCEPT DOUBLE MAT STEEL MAY BE USED IN LIEU :ANFAFtF eaTTrr I:Aa SHFFT 11- s"FE- : :lF a 1'-6" B40.34 Or ROOK BARS IN BASE SLAB. SECTION x-X (WITH ioe) 640.34 B40.34 840.34 FILTER FABRIC LAP (IF NEEDED) ELEVATION ALL RIPRAP SHALL BE CLASS B OR ENGINEER APPROVED. Sheet Title: APRON D(FT) La(FT) W1(FT) W2(FT) T(FT) D50(IN) DMAX(IN) H (IN) NATURAL GRADE FES-1 2.00 12 6.00 14.00 1.13 6.0 9.0 16.0 FES-L 2.00 12 6.00 14.00 1.13 6.0 9.0 16.0 EROSION '• «',::1. , V RIP RAP - ;'[•.7n - d=diameter .0 pipe CONTROL H d50 (see fig 8.06 aft "NC SEDIMENT AND EROSION CONTROL MANUAL" * dmax = 1.5 x d50 8 TRAFFIC BEARING JUNCTION BOX T (THICKNESS) 6.0 SCALE: N.T.S. [REF: NCDOT #840.34] T = 1.5 X dmax. I DETAILS NOTE: -LAYER OF FILTER FABRIC MIMMUM H=2/3 PIPE DIAMETER SECTION B-B Sheet No: Riprap Apron Detail 6.0 Ref: MCLDS Standard #20.23 ■ LEGEND SUBJECT PROPERTY BOUNDARY ADJACENT PARCELS / RIGHT—OF—WAY SETBACK 702 EXISTING TO -PO — — —ss — — — —SS — — — —SS EXISTING SANITARY SEWER EASEMENT _ — — _VV — — —W— — — —VV— — — —w— EXISTING WATERLINE EXISTING CREEK CENTERLINE —. — 20 FT CREEK BUFFER 702 PROPOSED GRADE y� WALLACE ROAD MAINTENANCE R/W) P rn / P ` P / / 502 �— �� � � fg4QY SUBBASIN 1 / - - _ 50d ., .FES2 / REA = 2 91 ACRES •c.��; pz HYDRIC SOIL GROUP = C--:�' — CN=85 TOC = 5 MIN 1 ST SEGMENT TO LENGTH =100 FT ELEV.CHANGE = 1 FT SLOPE = 0.9% GRAPHIC SCALE 60 0 30 60 120 r Firm License # P-1191 7140 Weddington Road Suite 140 Concord, NC 28027 Civil Site Design Low Impact Development Small —Scale Building Design Telephone: 704.573.1621 Facsimile: 704.248.7951 Seals: 0-I •9� SEAL 032006 N����'� OZA,S R .y•af. •zoI Q Q d n- z Q w T r L QU+ z O 0 U_...1 rz\ 4--� LLJ 1 H z T- --� L_ Project Number: 17.16.138 Date: 12/14/2017 Drawn By. CMM Checked By. NRP Rev15ion5: I / �=ij i 71 Vi\ivi'r � viJlVlii ir,� Sheet Title: POST - DEVELOPED DRAINAGE MAP Sheet No: C-7 , 1 COPYRIGHT© 2017 AMICUS PARTNERS, PLLC. ALL RIGHTS RESERVED. REPRODUCTION OR USE OF THE CONTENTS OF THIS DOCUMENT, OR ADDITIONS OR DELETIONS TO THIS REFERENCE: ALL PARCEL AND BOUNDARY INFORMATION FOR THIS PROPERTY AND DOCUMENT, IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT ADJACENT PROPERTIES, PROPERTY DIMENSIONS, AND COORIDINATES REFERENCED FROM OF AMICUS PARTNERS, IS STRICTLY PROHIBITED. ONLY CABARRUS COUNTY GIS. COPIES FROM THE ORIGINAL OF THIS DOCUMENT, AS APPROVED BY THE ENGINEER SHALL BE CONSIDERED TO BE VALID, TRUE COPIES.