Loading...
HomeMy WebLinkAboutWQ0018755_Staff Report_20190305Dow& n EnveloC1D:91C9B03F-C244-4BD5-AAEC-1B326EA5FOAF State of North Carolina Division of Water Resources Water Quality Regional Operations Section Environmental Staff Report Quality To: ❑ NPDES Unit ® Non -Discharge Unit Attn: (Tessa Monday) From: (Tom Tharrington) Wilmington Regional Office 1111witam k"7� W.Iel 17.y I I NkTA KI 18lei 010;7u /:110 Wei 1. Was a site visit conducted? ® Yes or ❑ No a. Date of site visit: 02-12-2019 b. Site visit conducted by: Tom Tharrington c. Inspection report attached? ® Yes or ❑ No Application No.: Aqua North Carolina, Inc. WQ0018755 Facility Name: Castle Bay WWTP d. Person contacted: Charles Bryan and their contact information: (910) 431-9265 e. Driving directions: Follow US-17N from Wilmington to Hampstead, turn left on Hoover Road (SR 1569) and follow for approximately 2.0 miles and turn right onto Castle Bay Drive. Follow Castle Bay Drive to first gravel road on the right and follow to WWTP. �!�.zHE ae�ss ��ss�� II. PROPOSED FACILITIES: NEW APPLICATIONS 3. Are depth tewa4er- table, the Ej Yes E No D N�A site eenditions (soils, ete) eensistent with s4miffed r-epol4s? if no, please • ifno, please explaiw: 5. is the ao,.,, �o� n Yes n N n N k proposed r-esiduals management if plan no, please • if no, please explain FORM: WQROSSR 04-14 Page 1 of 4 DocuSign Envelope ID: 91C9B03F-C244-4BD5-AAEC-1B326EA5FOAF S � � NOW I LUMP E 11. P_rot a t,v e t P,-oR,-.,m (POTWs only): III. EXISTING FACILITIES: MODIFICATION AND RENEWAL APPLICATIONS 1. Are there appropriately certified Operators in Charge (ORCs) for the facility? ® Yes ❑ No ❑ N/A ORC: Charles G. Bryan Backup ORC: Kirklyn B. Fields Certificate #: WW-2,1002563 Certificate #: WW-3, 996782 2. Are the design, maintenance and operation of the treatment facilities adequate for the type of waste and disposal system? ® Yes or ❑ No If no, please explain: Description of existing facilities: The Castle Bay WWTF is a 100,000 GPD dual train extended aeration activated sludge process with spray irrigation disposal. Influent wastewater enters a single 25,000 gallon aerated flow equalization tank through a single manually cleaned bar screen and dual adjustable weirs for flow control to each train. A single 85 cfm blower provides aeration for this equalization tank, and dual 50 gpm flow equalization pumps are used to transfer influent into the aeration tanks and are controlled with a series of float switches. Dual 62,500 gallon aeration tanks are operated in parallel and aeration is provided by three (3) positive displacement blowers and air headers with coarse bubble diffusers. Wastewater passes from the aeration tank(s) into each of two (2) rectangular 8,333 gallon hopper -type clarifier units. Return activated sludge (RAS) is conveyed to each aeration tank from a single air-lift pump with an associated surface skimmer. Clarified effluent then passes to dual 35 ft2 tertiary filters with 140 cfm blowers and 525 gpm backwash pump(s) for each. During a backwash cycle, solids removed during the backwash flow to a small mud well where float controlled, dual 90 gpm backwash surge or mud well pumps are used to return the flow to the influent flow equalization tank. Filtered effluent then passes through a dual bank Trojan® UV 3000PTP for disinfection, past a Hach® in -line turbidimeter with a Honeywell® chart recorder and is then transferred to a 5.4 MG effluent storage pond by dual 89 gpm effluent pumps. If required, effluent with high turbidity is automatically diverted to a 500,000 gallon upset pond adjacent to the WWTP. A small transfer pump is used to return any diverted water to the influent flow equalization tank for retreatment. Waste activated sludge (WAS) is removed from the process as needed by manually operating control valves on the RAS recycle line and diverting flow into a single 15,000 gallon aerated sludge storage tank. Proposed flow: 100,000 GPD Current permitted flow: 100,000 GPD During the last inspection, the following items were noted.... • The 5-Day Upset Pond liner has been replaced • Five (5) new air compressors have been added to replace previously used blowers, three (3) are dedicated for aeration basin use, the others for filter backwash and sludge digester. • The auto-dailer has been upgraded to a newer unit with more alarm notifications • Castle Bay Golf Course staff conducts all irrigation activities and provide records of irrigation events to Aqua North Carolina, Inc., Aqua staff could not produce any documents of annual calibration of the FORM: WQROSSR 04-14 Page 2 of 4 DocuSign Envelope ID: 91C9BO3F-C244-4BD5-AAEC-1B326EA5FOAF irrigation equipment as required by the existing permit. Aqua NC staff were to investigate application procedures and develop a calibration method. 3. Are the site conditions (e.g., soils, topography, depth to water table, etc) maintained appropriately and adequately assimilating the waste? ® Yes or ❑ No If no, please explain: 4. Has the site changed in any way that may affect the permit (e.g., drainage added, new wells inside the compliance boundary, new development, etc.)? ❑ Yes or ® No If yes, please explain: 5. Is the residuals management plan adequate? ® Yes or ❑ No If no, please explain: 6. Are the existing application rates (e.g., hydraulic, nutrient) still acceptable? ® Yes or ❑ No If no, please explain: 7. Is the existing groundwater monitoring program adequate? ® Yes ❑ No ❑ N/A If no, explain and recommend any changes to the groundwater monitoring program: 8. Are there any setback conflicts for existing treatment, storage and disposal sites? ❑ Yes or ® No If yes, attach a map showing conflict areas. 9. Is the description of the facilities as written in the existing permit correct? ® Yes or ❑ No If no, please explain: 10. Were monitoring wells properly constructed and located? ® Yes ❑ No ❑ N/A If no, please explain: 11. Are the monitoring well coordinates correct in BIMS? ® Yes ❑ No ❑ N/A If no, please complete the following (expand table if necessary): Monitoring Well Latitude Longitude O / // O / // O / // O / // O // O / II O // O / II 12. Has a review of all self -monitoring data been conducted (e.g., DMR, NDMR, NDAR, GW)? ® Yes or ❑ No Please summarize any findings resulting from this review: A review of the NDMR's since 2013 indicate occasional violations for fecal coliform, most violations were monitoring frequency violations generated from failure to report turbiditv values over the weekend periods. this is currentiv being addressed by reportina <10 NTU if no diversion occurs. A review of GW-59 data since 2013 indicates elevated Total Ammonia, Nitrogen (00610) in monitoring well #2 & #3 for the past several years, while BIMS flags this as a violation the current permit has no limit for this parameter. This ammonia level is believed to be a result of the poor soils and siting of these monitoring wells. 13. Are there any permit changes needed in order to address ongoing BIMS violations? ❑ Yes or ® No If yes, please explain: 14. Check all that apply: ® No compliance issues ❑ Current enforcement action(s) ❑ Currently under JOC ❑ Notice(s) of violation ❑ Currently under SOC ❑ Currently under moratorium Please explain and attach any documents that may help clarify answer/comments (i.e., NOV, NOD, etc.) Have all compliance dates/conditions in the existing permit been satisfied? ❑ Yes ❑ No ® N/A If no, please explain: FORM: WQROSSR 04-14 Page 3 of 4 DocuSign Envelope ID: 91C9BO3F-C244-4BD5-AAEC-1B326EA5FOAF 15. Are there any issues related to compliance/enforcement that should be resolved before issuing this permit? ❑ Yes ®No❑N/A If yes, please explain: IV. REGIONAL OFFICE RECOMMENDATIONS 1. Do you foresee any problems with issuance/renewal of this permit? ❑ Yes or ® No If yes, please explain: Hein Reason 5. Recommendation: ❑ Hold, pending receipt and review of additional information by regional office ❑ Hold, pending review of draft permit by regional office ❑ Issue upon receipt of needed additional information ® Issue ❑ Den PDIe v estate reasons: ) 6. Signature of report preparer: ►MAS bin, Signature of regional supervi Date: 2/28/2019 E73B6F3456... Docu Signed by: �v"uq� E LbVY,�,�Ct. � � 6U E3ABA14AC7DC434... FORM: WQROSSR 04-14 Page 4 of 4 DocuSign Envelope ID: 91C9B03F-C244-4BD5-AAEC-1B326EA5FOAF Compliance Inspection Report Permit: WQ0018755 Effective: 05/11/07 Expiration: 04/30/16 owner: Aqua North Carolina Inc SOC: Effective: Expiration: Facility: Castle Bay WWTP County: Pender Castle Bay Dr Region: Wilmington Hampstead NC 28443 Contact Person: Joel A Mingus Title: Coastal Area Manager Phone: 910-270-1412 Directions to Facility: System Classifications: SI, WW2, Primary ORC: Charles Gardner Bryan Secondary ORC(s): On -Site Representative(s): Related Permits: Certification: 1003562 Phone: 910-431-9265 Inspection Date: 02/12/2019 Entry Time: 09:55AM Exit Time: 11:15AM Primary Inspector: Tom Tharrington DocuSigned by: Phone: Secondary Inspector(s): tbk&S Tt,AY' IA46t& 2/25/2019 D7F141E73B6F3456 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Reclaimed Water Facility Status: Compliant Not Compliant Question Areas: Miscellaneous Questions Treatment Treatment Barscreen Treatment Filters Record Keeping Treatment Lagoons Treatment Activated Sludge Treatment Sludge Storage/Treatment Treatment Clarifiers Treatment Disinfection Treatment Return pumps Storage Standby Power (See attachment summary) Page: 1 DocuSign Envelope ID: 91 C9BO3F-C244-4BD5-AAEC-1 B326EA5FOAF Permit: WQ0018755 Owner - Facility: Aqua North Carolina Inc Inspection Date: 02/12/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: This facility continues to improve with replacement/upgrades to several treatment components including new air compressors, air piping and headers, new diffuser drops and diffusers. The auto -dialer has recently been upgraded to include notifications for high turbidity, high equalization chamber level, high mudwell level, high dosing tank level and power failure. The 5-day upset pond liner has been replaced in the last few years along with exterior painting and new control panels. The ORC indicated the initial plans for influent screening/grit removal equipment have been discussed and this may be a possible equipment addition in the future. The auto -sampler used for effluent sampling is an ISCO 5800, it is a flow proportional unit taking its signal from the effluent flowmeter. The refrigerated compartment is maintained at 3.8°C. The effluent flowmeter is an ISCO 4230 Bubbler Flow Meter (differential pressure) and is due for a calibration check in April 2019. This is a newer unit installed in the last 2 years. The on-line turbidimeter is an HACH 1720E low range meter and was last calibrated on October 10, 2018. A review of the Reclaimed Water Storage Pond was conducted, and the entire dike roadway was observed, as was each of the monitoring wells. No excessive vegetative or tree growth was affecting the pond berms and the roadway was in good condition. All monitoring wells were accessible, labeled and locked. The remaining issue to address at this site is the annual calibration of irrigation application equipment. While the reclaimed water is applied to the golf course as needed by greenkeeping staff and is certainly within application limits as the course must remain playable all season, it is a requirement to confirm these application rates. Discussions have included the addition of a flowmeter measuring the water taken from the storage pond for irrigation purposes as being a starting point for this application confirmation. Pump curves and line/nozzle pressure readings could also be used to calculate flowrates and application volumes over the irrigation areas. Additional comments are noted within the questions section of this report. Page: 2 DocuSign Envelope ID: 91 C9BO3F-C244-4BD5-AAEC-1 B326EA5FOAF Permit: WQ0018755 Owner - Facility: Aqua North Carolina Inc Inspection Date: 02/12/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Type Yes No NA NE Infiltration System ❑ Lagoon Spray, LR ❑ Recycle/Reuse ❑ Single Family Drip ❑ Activated Sludge Spray, HR ❑ Single Family Spray, LR ❑ Activated Sludge Drip, LR ❑ Activated Sludge Spray, LR ❑ Reuse (Quality) Treatment Yes No NA NE Are Treatment facilities consistent with those outlined in the current permit? 0 ❑ ❑ ❑ Do all treatment units appear to be operational? (if no, note below.) 0 ❑ ❑ ❑ Comment: Recently completed improvements include five new air compressors, air headers, air drops, valves and diffusers. The exterior surfaces have been repainted and new control panels added for the new components. The Auto -dialer notification unit has also been upgraded to a Omnisite "Crystal Ball" unit to include more alarm points. Standby Power Yes No NA NE Is automatically activated standby power available? ❑ ❑ ❑ Is generator tested weekly by interrupting primary power source? ❑ ❑ ❑ Is generator operable? ❑ ❑ ❑ Does generator have adequate fuel? 0 ❑ ❑ ❑ Comment: The facility is relying on a portable generator for power if needed, the existing generator has a low voltage issue and is scheduled to be replaced in the near term. Treatment Barscreen Yes No NA NE Is it free of excessive debris? ❑ ❑ ❑ Is disposal of screenings in compliance? ❑ ❑ ❑ Are the bars spaced properly? ❑ ❑ ❑ Is the unit in good condition? ❑ ❑ ❑ Comment: The barscreen unit has a manually cleaned stainless steel rack with debris drying area. Treatment Activated Sludqe Yes No NA NE Is the aeration mechanism operable? 0 ❑ ❑ ❑ Is the aeration basin thoroughly mixed? 0 ❑ ❑ ❑ Is the aeration equipment easily accessed? 0 ❑ ❑ ❑ Is Dissolved Oxygen adequate? 0 ❑ ❑ ❑ Page: 3 DocuSign Envelope ID: 91 C9B03F-C244-4BD5-AAEC-1 B326EA5FOAF Permit: WQ0018755 Owner - Facility: Aqua North Carolina Inc Inspection Date: 02/12/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Are Settleometer results acceptable? 0 ❑ ❑ ❑ Is activated sludge an acceptable color? 0 ❑ ❑ ❑ Comment: The aeration basin mixed liquor appeared to have the appropriate color, density and surface foam indicating proper operation. Settlometer results are typically 600 SV units in 30 mins. A review of operator's records show effluent dissolved oxygen levels are within a range of 8.25 mg/I to 10.0 mg/I for the month of February. Effluent off are consistently between 7.0 to 7.5 SU. Treatment Clarifiers Yes No NA NE Are the weirs level? ❑ ❑ ❑ Are the weirs free of solids and algae? ❑ ❑ ❑ Is the scum removal system operational? ❑ ❑ ❑ Is the scum removal system accessible? ❑ ❑ ❑ Is the sludge blanket at an acceptable level? ❑ ❑ ❑ Is the effluent from the clarifier free of excessive solids? 0 ❑ ❑ ❑ Comment: Clarifier appeared clean with a small amount of surface "ashing" that was being adequately removed by the surface skimmer units. Treatment Return pumps Yes No NA NE Are they in place? 0 ❑ ❑ ❑ Are they operational? 0 ❑ ❑ ❑ Comment: RAS pumps are all air lift pumps driven with compressed air, the RAS and surface skimmers appeared to be adjusted to the proper return rates. A large electric mud pump with a flexible suction hose is available to the operator for miscellaneous uses. This pump is directed to the digester compartment for disposal. Treatment Filters Yes No NA NE Is the filter media present? 0 ❑ ❑ ❑ Is the filter media the correct size and type? 0 ❑ ❑ ❑ Is the air scour operational? 0 ❑ ❑ ❑ Is the scouring acceptable? ❑ ❑ ❑ Is the clear well free of excessive solids? 0 ❑ ❑ ❑ Is the mud well free of excessive solids and filter media? ❑ ❑ ❑ Does backwashing frequency appear adequate? ❑ ❑ ❑ Comment: Filters are functionina as desianed. the filter backwash is directed to the from of the treatment system via the mudwell pumps and another portion is directed to the 5-day upset pond through the mudwell drain valve and piping. Treatment Sludge Storage/Treatment Yes No NA NE Is the aeration operational? ❑ ❑ ❑ Is the aeration pattern even? ❑ ❑ ❑ If required, are Sanitary "Ts" present in tankage? ❑ ❑ ❑ Page: 4 DocuSign Envelope ID: 91C9B03F-C244-4BD5-AAEC-1B326EA5FOAF Permit: WQ0018755 Owner - Facility: Aqua North Carolina Inc Inspection Date: 02/12/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Comment: The operator was decanting the settled sludge with an electric sump pump during the inspection. When decanting of the sludge is no longer productive and the digester compartment is near capacity the residuals are removed by Lewis Farms and disposed of on their permitted application sites. Treatment Disinfection Yes No NA NE Is the system working? ❑ ❑ ❑ Do the fecal coliform results indicate proper disinfection? ❑ ❑ ❑ Is there adequate detention time (-30 minutes)? ❑ ❑ ❑ Is the system properly maintained? ❑ ❑ ❑ If gas, does the cylinder storage appear safe? ❑ ❑ ❑ Is the fan in the chlorine feed room and storage area operable? ❑ ❑ ❑ Is the chlorinator accessible? ❑ ❑ ❑ If tablets, are tablets present? ❑ ❑ ❑ Are the tablets the proper size and type? ❑ ❑ ❑ Is contact chamber free of sludge, solids, and growth? ❑ ❑ ❑ If UV, are extra UV bulbs available? ❑ ❑ ❑ If UV, is the UV intensity adequate? ❑ ❑ ❑ # Is it a dual feed system? ❑ ❑ ❑ Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? ❑ ❑ ❑ If yes, then is there a Risk Management Plan on site? ❑ ❑ ❑ If yes, then what is the EPA twelve digit ID Number? (1000--) If yes, then when was the RMP last updated? Comment: The UV system is maintained with monthly cleaning of bulb sleeves, during this time any bulb issues are addressed and replaced as needed. Annually the UV units have the 12 bulbs and sleeves replaced. Record Keeping Yes No NA NE Is a copy of current permit available? ❑ ❑ ❑ Are monitoring reports present: NDMR? ❑ ❑ ❑ NDAR? ❑ ❑ ❑ Are flow rates less than of permitted flow? ❑ ❑ ❑ Are flow rates less than of permitted flow? ❑ ❑ ❑ Are application rates adhered to? ❑ ❑ ❑ Is GW monitoring being conducted, if required (GW-59s submitted)? ❑ ❑ ❑ Are all samples analyzed for all required parameters? ❑ ❑ ❑ Are there any 2L GW quality violations? ❑ ❑ ❑ Is GW-59A certification form completed for facility? ❑ ❑ ❑ Is effluent sampled for same parameters as GW? ❑ ❑ ❑ Page: 5 DocuSign Envelope ID: 91 C9B03F-C244-4BD5-AAEC-1 B326EA5FOAF Permit: WQ0018755 Owner - Facility: Aqua North Carolina Inc Inspection Date: 02/12/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Do effluent concentrations exceed GW standards? ❑ ❑ ❑ Are annual soil reports available? ❑ ❑ ❑ # Are PAN records required? ❑ ❑ ❑ # Did last soil report indicate a need for lime? ❑ ❑ ❑ If so, has it been applied? ❑ ❑ ❑ Are operational logs present? ❑ ❑ ❑ Are lab sheets available for review? ❑ ❑ ❑ Do lab sheets support data reported on NDMR? ❑ ❑ ❑ Do lab sheets support data reported on GW-59s? ❑ ❑ ❑ Are Operational and Maintenance records present? ❑ ❑ ❑ Were Operational and Maintenance records complete? ❑ ❑ ❑ Has permittee been free of public complaints in last 12 months? ❑ ❑ ❑ Is a copy of the SOC readily available? ❑ ❑ ❑ No treatment units bypassed since last inspection? 0 ❑ ❑ ❑ Comment: During the inspection a review of the operator readings sheets and logbook was conducted, and all items appeared in order. MW-3 does continue to have exceedances for ammonia which is unusual for natural groundwaters. It is believed this is due to the monitoring well siting and not indicative of effluent ug ality. Page: 6 Docu5�". 6 S E C U R E 6 Certificate Of Completion Envelope Id: 91C9B03FC2444BD5AAEC1B326EA5FOAF Status: Completed Subject: Please DocuSign: CastleBay WQ0018755 StaffRpt2019.docx, CBay Inspection 2-12-19.pdf Source Envelope: Document Pages: 10 Signatures: 3 Envelope Originator: Certificate Pages: 2 Initials: 0 Thomas Tharrington AutoNav: Enabled 217 W. Jones Street Envelopeld Stamping: Enabled Raleigh, NC 27699 Time Zone: (UTC-08:00) Pacific Time (US & Canada) tom.tharrington@ncdenr.gov IP Address: 149.168.204.10 Record Tracking Status: Original Holder: Thomas Tharrington Location: DocuSign 2/25/2019 12:04:09 PM tom.tharrington@ncdenr.gov Signer Events Signature Timestamp DocuSignetl by: Thomas Tharrington D7F141E73B6F3456... Sent: 2/25/2019 12:07:19 PM u oW.S I u,avritn�{-Oln tom.tharrington@ncdenr.gov Viewed: 2/25/2019 12:07:28 PM North Carolina Department of Environmental Quality Signed: 2/25/2019 12:08:23 PM Security Level: Email, Account Authentication Freeform Signing (None) Signature Adoption: Pre -selected Style Using IP Address: 149.168.204.10 Electronic Record and Signature Disclosure: Not Offered via DocuSign Morelia Sanchez King-,- ED—Signed ''. • n Au� by: s 6In., Sent: 2/25/2019 12:08:24 PM morella.sanchez-king@ncdenr.gov Viewed: 2/28/2019 7:36:45 AM Interim Regional Supervisor Wilmington Regional E3ABA14Ac7Dc434 Signed: 2/28/2019 7:39:06 AM Office Freeform Signing Division of Water Resources- Water Quality Signature Adoption: Pre -selected Style Regional Operations Section Using IP Address: 149.168.204.10 Security Level: Email, Account Authentication (None) Electronic Record and Signature Disclosure: Not Offered via DocuSign In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 2/25/2019 12:08:24 PM Certified Delivered Security Checked 2/28/2019 7:36:45 AM Signing Complete Security Checked 2/28/2019 7:39:06 AM Completed Security Checked 2/28/2019 7:39:06 AM Payment Events Status Timestamps