Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NCG020354_2016 Analytical Results Wastewater_20160114
AT 1_,A11(ac6Ana1j4ica1 www.pacelabs.com i Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 January 14, 2016 Glenn Amey Charrah 330 S Tryon St Suite 510 Charlotte, NC 28202 RE: Project: Sed Basin 7 1/7 Pace Project No.: 92282272 PcCr6-Q 3S�-/ JA iAN 3 Z7 CEN L 1--ILE11 DWRYSE;C7', t Dear Glenn Amey: Enclosed are the analytical results for sample(s) received by the laboratory on January 07, 2016. The results relate only to the samples included in this report. Results reported herein conform to the most current TNI standards and the laboratory's Quality Assurance Manual, where applicable, unless otherwise noted in the body of the report. Analyses were performed at the Pace Analytical Services location indicated on the sample analyte page for analysis unless otherwise footnoted. If you have any questions concerning this report, please feel free to contact me. Sincerely, Chris Derouen christopher.derouen@pacelabs.com Project Manager Enclosures %4 pCCRFO�� REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page 1 of 19 aceAnalytical www.pacelabs.com Pace Analytical Services, Inc. 2225 Riverside Dr, Asheville, NC 28804 (828)254-7176 Project: Sed Basin 7 1/7 Pace Project No.: 92282272 Raleigh Certification IDs 6701 Conference Drive, Raleigh, NC 27607 North Carolina Wastewater Certification #: 67 Eden Certification IDs 205 East Meadow Road Suite A, Eden, NC 27288 North Carolina Drinking Water Certification #: 37738 CERTIFICATIONS North Carolina Bioassay Certification #: 16 North Carolina Drinking Water Certification #: 37731 North Carolina Wastewater Certification #: 633 Virginia/VELAP Certification #: 460025 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page 2 of 19 [ F aceAna1j caf www.pacelabs.com I Project: Sed Basin 7 1/7 Pace Project No.: 92282272 Lab ID Sample ID 92282272001 SED 7 Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 SAMPLE ANALYTE COUNT Method Analysts Analytes Reported Laboratory SM 2130B DWJ 1 PASI-E SM 2540D CHM 1 PASI-E SM 2540F DWJ 1 PASI-E EPA 9040 KCE 1 PASI-E SM 9222D RC 1 PASI-R REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page 3 of 19 aceAnalytical o www.pacelabs.com Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 SUMMARY OF DETECTION Project: Sed Basin 7 1/7 Pace Project No.: 92282272 Lab Sample ID Method Client Sample ID Parameters Result Units 92282272001 SED 7 SM 2130B Turbidity 9.6 NTU SM 2540D Total Suspended Solids 7.9 mg/L EPA 9040 pH 4.2 Std. Units SM 9222D Fecal Coliforms 4.0 CFU/100 mL REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Report Limit Analyzed Qualifiers 0.50 01/08/1611:10 2.5 01/08/1611:27 0.10 01/08/1611:47 H6 1.0 01/07/1616:20 1g Page 4 of 19 ,�aceAnalyfical' www.pacelabs.com I PROJECT NARRATIVE Project: Sed Basin 7 1/7 Pace Project No.: 92282272 Method: SM 2130B Description: 2130E Turbidity EDN Client: Charah Date: January 14, 2016 Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 General Information: 1 sample was analyzed for SM 2130B. All samples were received in acceptable condition with any exceptions noted below or on the chain -of custody and/or the sample condition upon receipt form (SCUR) attached at the end of this report. Hold Time: The samples were analyzed within the method required hold times with any exceptions noted below. Initial Calibrations (including MS Tune as applicable): All criteria were within method requirements with any exceptions noted below. Continuing Calibration: All criteria were within method requirements with any exceptions noted below. Internal Standards: All internal standards were within QC limits with any exceptions noted below. Surrogates: All surrogates were within QC limits with any exceptions noted below. Method Blank: All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below. Laboratory Control Spike: All laboratory control spike compounds were within QC limits with any exceptions noted below. Matrix Spikes: All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below. Duplicate Sample: All duplicate sample results were within method acceptance criteria with any exceptions noted below. Additional Comments: REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page 5 of 19 t s aCoe Analytical - www.pacelabs.com Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 PROJECT NARRATIVE Project: Sed Basin 7 1/7 Pace Project No.: 92282272 Method: SM 2540D Description: 2540D Total Suspended Solids Client: Charah Date: January 14, 2016 General Information: 1 sample was analyzed for SM 2540D. All samples were received in acceptable condition with any exceptions noted below or on the chain -of custody and/or the sample condition upon receipt form (SCUR) attached at the end of this report. Hold Time: The samples were analyzed within the method required hold times with any exceptions noted below. Initial Calibrations (including MS Tune as applicable): All criteria were within method requirements with any exceptions noted below. Continuing Calibration: All criteria were within method requirements with any exceptions noted below. Internal Standards: All internal standards were within QC limits with any exceptions noted below. Surrogates: All surrogates were within QC limits with any exceptions noted below. Method Blank: All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below. Laboratory Control Spike: All laboratory control spike compounds were within QC limits with any exceptions noted below. Matrix Spikes: All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below. Duplicate Sample: All duplicate sample results were within method acceptance criteria with any exceptions noted below. QC Batch: EDEN/21359 D6: The relative percent difference (RPD) between the sample and sample duplicate exceeded laboratory control limits. • DUP (Lab ID: 1643609) • Total Suspended Solids Additional Comments: REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page 6 of 19 aceAnalytical www.pacelabs.com Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 PROJECT NARRATIVE Project: Sed Basin 7 1/7 Pace Project No.: 92282272 Method: SM 2540F Description: 2540F Total Settleable Solids Client: Charah Date: January 14, 2016 General Information: 1 sample was analyzed for SM 2540F. All samples were received in acceptable condition with any exceptions noted below or on the chain -of custody and/or the sample condition upon receipt form (SCUR) attached at the end of this report. Hold Time: The samples were analyzed within the method required hold times with any exceptions noted below. Initial Calibrations (including MS Tune as applicable): All criteria were within method requirements with any exceptions noted below. Continuing Calibration: All criteria were within method requirements with any exceptions noted below. Internal Standards: All internal standards were within QC limits with any exceptions noted below. Surrogates: All surrogates were within QC limits with any exceptions noted below. Method Blank: All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below. Laboratory Control Spike: All laboratory control spike compounds were within QC limits with any exceptions noted below. Matrix Spikes: All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below. Additional Comments: REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page 7 of 19 0 aceAna1j cal ® www.pacelabs.com Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 PROJECT NARRATIVE Project: Sed Basin 7 1/7 Pace Project No.: 92282272 Method: EPA 9040 Description: 9040 pH Client: Charah Date: January 14, 2016 General Information: 1 sample was analyzed for EPA 9040. All samples were received in acceptable condition with any exceptions noted below or on the chain -of custody and/or the sample condition upon receipt form (SCUR) attached at the end of this report. Hold Time: The samples were analyzed within the method required hold times with any exceptions noted below. H6: Analysis initiated outside of the 15 minute EPA recommended holding time. • SED 7 (Lab ID: 92282272001) Initial Calibrations (including MS Tune as applicable): All criteria were within method requirements with any exceptions noted below. Continuing Calibration: All criteria were within method requirements with any exceptions noted below. Internal Standards: All internal standards were within QC limits with any exceptions noted below. Surrogates: All surrogates were within QC limits with any exceptions noted below. Method Blank: All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below. Laboratory Control Spike: All laboratory control spike compounds were within QC limits with any exceptions noted below. Matrix Spikes: All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below. Duplicate Sample: All duplicate sample results were within method acceptance criteria with any exceptions noted below. Additional Comments: REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page 8 of 19 a aceAnalytical www.pacelabs.com Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 PROJECT NARRATIVE Project: Sed Basin 7 1/7 Pace Project No.: 92282272 Method: SM 9222D Description: MBIO 9222D Fecal Coliform RAL Client: Charah Date: January 14, 2016 General Information: 1 sample was analyzed for SM 9222D. All samples were received in acceptable condition with any exceptions noted below or on the chain -of custody and/or the sample condition upon receipt form (SCUR) attached at the end of this report. Hold Time: The samples were analyzed within the method required hold times with any exceptions noted below. Initial Calibrations (including MS Tune as applicable): All criteria were within method requirements with any exceptions noted below. Continuing Calibration: All criteria were within method requirements with any exceptions noted below. Internal Standards: All internal standards were within QC limits with any exceptions noted below. Surrogates: All surrogates were within QC limits with any exceptions noted below. Method Blank: All analytes were below the report limit in the method blank, where applicable, with any exceptions noted below. Laboratory Control Spike: All laboratory control spike compounds were within QC limits with any exceptions noted below. Matrix Spikes: All percent recoveries and relative percent differences (RPDs) were within acceptance criteria with any exceptions noted below. Duplicate Sample: All duplicate sample results were within method acceptance criteria with any exceptions noted below. Additional Comments: Analyte Comments: QC Batch: RB10/5848 1g: This is a less than value • SED 7 (Lab ID: 92282272001) • Fecal Coliforms This data package has been reviewed for quality and completeness and is approved for release. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page 9 of 19 Pace Analytical Services, Inc. aceAnalytical 2225 Riverside Dr. J Asheville, NC 28804 www.pacelabs.com I (828)254-7176 ANALYTICAL RESULTS Project: Sed Basin 7 1/7 Pace Project No.: 92282272 Sample: SED 7 Lab ID: 92282272001 Collected: 01/07/16 12:00 Received: 01/07/16 16:10 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qua[ 2130E Turbidity EDN Analytical Method: SM 2130B Turbidity 9.6 NTU 0.50 1 01/08/1611:10 2540D Total Suspended Solids Analytical Method: SM 2540D Total Suspended Solids 7.9 mg/L 2.5 1 01/08/16 11:27 254OF Total Settleable Solids Analytical Method: SM 2540F Total Settleable Solids ND mL/L/hr 0.10 1 01/08/16 11:10 9040 pH Analytical Method: EPA 9040 pH 4.2 Std. Units 0.10 1 01/08/16 11:47 H6 MBIO 9222D Fecal Coliform RAL Analytical Method: SM 9222D Fecal Coliforms 4.0 CFU/100 mL 1.0 1 01/07/16 16:20 1g REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01 /14/2016 10:33 AM without the written consent of Pace Analytical Services, Inc.. Page 10 of 19 aceAnalytical www.pacelabs.com Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Project: Sed Basin 7 1/7 Pace Project No.: 92282272 QC Batch: EDEN/21357 Analysis Method: SM 2130B QC Batch Method: SM 2130B Analysis Description: 2130E Turbidity EDN Associated Lab Samples: 92282272001 METHOD BLANK: 1643578 Matrix: Water Associated Lab Samples: 92282272001 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Turbidity NTU ND 0.50 01/08/1611:10 SAMPLE DUPLICATE: 1643579 92282272001 Dup Parameter Units Result Result Turbidity NTU 9.6 9.6 RPD Qualifiers 0 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01/14/2016 10:33 AM without the written consent of Pace Analytical Services, Inc.. Page 11 of 19 aceAnalj6cal www.pacelabs.com Pace Analytical Services, Inc. 2225 Riverside Dr, Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Project: Sed Basin 7 1/7 Pace Project No.: 92282272 QC Batch: EDEN/21359 Analysis Method: SM 2540D QC Batch Method: SM 2540D Analysis Description: 2540D Total Suspended Solids Associated Lab Samples: 92282272001 METHOD BLANK: 1643607 Matrix: Water Associated Lab Samples: 92282272001 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Total Suspended Solids mg/L ND 2.5 01/08/16 11:26 LABORATORY CONTROL SAMPLE: 1643608 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Total Suspended Solids mg/L 250 242 97 90-110 SAMPLE DUPLICATE: 1643609 92282233001 Dup Parameter Units Result Result RPD Qualifiers Total Suspended Solids mg/L 72.0 67.2 7 D6 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01 /14/2016 10:33 AM without the written consent of Pace Analytical Services, Inc.. Page 12 of 19 aceAnalytical @ www.pacelabs.com Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Project: Sed Basin 7 1/7 Pace Project No.: 92282272 QC Batch: EDEN/21356 Analysis Method: SM 254OF QC Batch Method: SM 2540F Analysis Description: 2540F Total Settable Solids Associated Lab Samples: 92282272001 METHOD BLANK: 1643576 Associated Lab Samples: 92282272001 Parameter Units Total Settleable Solids mL/L/hr Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 0.10 01/08/1611:10 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01 /14/2016 10:33 AM without the written consent of Pace Analytical Services, Inc.. Page 13 of 19 ar _ aceAnalyticai www.pacelabs.com I QUALITY CONTROL DATA Project: Sed Basin 7 1/7 Pace Project No.: 92282272 QC Batch: EDEN/21361 Analysis Method: EPA 9040 QC Batch Method: EPA 9040 Analysis Description: 9040 pH EDEN Associated Lab Samples: 92282272001 SAMPLE DUPLICATE: 1643679 Parameter pH 92282272001 Dup Units Result Result RPD Qualifiers Std. Units 4.2 4.2 0 H6 Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01 /14/2016 10:33 AM without the written consent of Pace Analytical Services, Inc.. Page 14 of 19 aceAnalytical www.pacelabs.com Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 Project: Sed Basin 7 1/7 Pace Project No.: 92282272 QC Batch: R1310/5848 QC Batch Method: SM 9222D Associated Lab Samples: 92282272001 METHOD BLANK: 1643328 Associated Lab Samples: 92282272001 Parameter Fecal Coliforms SAMPLE DUPLICATE: 1643329 Parameter Fecal Coliforms QUALITY CONTROL DATA Analysis Method: SM 9222D Analysis Description: 9222D MBIO Fecal Coliform - RAL Matrix: Water Blank Reporting Units Result Limit Analyzed Qualifiers CFU/100 mL ND 1.0 01/07/16 15:35 92282231001 Dup Units Result Result RPD Qualifiers CFU/100 mL 6.0 17.0 96 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01 /14/2016 10:33 AM without the written consent of Pace Analytical Services, Inc.. Page 15 of 19 Pace Analytical Services, Inc. ® 2225 Riverside Dr. aceAna1j&a1Asheville, NC 28804 www.pacelabs.com (828)254-7176 QUALIFIERS Project: Sed Basin 7 1/7 Pace Project No.: 92282272 DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL -Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean -Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether, Styrene, and Vinyl chloride. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI -The NELAC Institute. LABORATORIES PASI-E Pace Analytical Services - Eden PASI-R Pace Analytical Services - Raleigh ANALYTE QUALIFIERS 1g This is a less than value D6 The relative percent difference (RPD) between the sample and sample duplicate exceeded laboratory control limits. H6 Analysis initiated outside of the 15 minute EPA recommended holding time. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01/14/2016 10:33 AM without the written consent of Pace Analytical Services, Inc.. Page 16 of 19 aceAnalytical www.pacelabs.com Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: Sed Basin 7 1/7 Pace Project No.: 92282272 Lab ID Sample ID QC Batch Method QC Batch 92282272001 SED 7 SM 2130B EDEN/21357 92282272001 SED 7 SM 2540D EDEN/21359 92282272001 SED 7 SM 2540F EDEN/21356 92282272001 SED 7 EPA 9040 EDEN/21361 92282272001 SED 7 SM 9222D RB10/5848 Date: 01 /14/2016 10:33 AM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Analytical Method Analytical Batch Page 17 of 19 -_ aceAnalytical wwrw.pscelsbs.cam 6701 Conference Drive, Raleigh, NC 27607 ph: (919) 834-4984, fax: (919) 834-6497 NCWW CerM7, NCDW Cert#37731 Chain oCustody Report Results To: Company: Address: M fit Attn: _M:rt�e.t-+'' Fax: �'�i (VKcI't`C C, )tnk • �y� Sampled by (signature): Bill To: Project Reference: :!�c- s; n -' 12 i'�_1t p_rctT_ Project Number: Purchase Order #: • Standard Report Delivery ❑ Rush Report Delivery (w/surcharge) `Rush projects are subject to prior approval by the laboratory Requested Due Date: Page 18 of 19 Document Name: Document No.: Document Revised: 260CT2015 Page 1 of 2 Issuing Authority. Pace Huntersville Quality Office Client Name: Nra,�mrey; Project #; : `� M 1�11� Courier: ❑Fed Ex []UPS ❑LISPS [Cllent II II 'III I I iII II nCommerclal ❑Pace Other: 1 92282272 Custody Seal on Cooler/Box Present? ❑Yes Qdo Seats intact? Dyes PKo Packing Material: ❑Bubble Wrap []Hubble Bags [/None ❑Other: Thermometer AIR Gun SN: 122065387 Used: ❑ IR Gun SN:122065371 Type of ice: [ Yet []Blue []None []Samples on Ice, cooling process has begun Cooler Temp Corrected (`C): r Biological Tissue Frozen? []Yes ❑No N/A Temp should be above fre zing to 61C Correction Factor: 010 °C Date and Initials of Person Examining Contents USDA Regulated Soil ( (?N/A, water sample) Did samples o_r,l8Inate in a quarantine zone within the United States: CA, NY, or SC (check maps)? Did samples originate from a foreign source (internationally, []Yes (,QN0 Including Hawaii and Puerto Rico)? ❑Yes "No if Yes to either question, fill out a Regulated Soil Checklist and Include with 5CURICOC oaverwork. / COMMENTS: Chain of Custody Present? Yes ONO ❑N/A 1, Chain of Custody Filled Out? Yes ONO N/A 2. Chalri of Custody Relinquished? iAYes ONO ❑N/A 3. Sampler Name and/or Signature on COC? Yes ONO ❑N/A 4. Samples Arrived within Hold Time? Yes ONO N/A S. Short Hold time Anal sis <72 fir)? Yes LINO CINJA 6qI Rush Turn Around Time Requested? Oyes dNo N/A 7. Sufficient Volume? MYes ONO N/A 8. Correct Containers Used? -Pace Containers Used? es ges ONO ONO ❑N/A ❑N/A 9. Containers Intact? Yes ONO ❑N/A 10. Filtered Volume Received for Dissolved Tests? OYes ONO AN/A 11. Note if Sediment Is vlsible In the dissolved container Sample Labels Match COC? -includes Date/Time/ID/Analysis Matrix: yes ONO ❑N/A 12. All containers needing acid/base preservation have been checked? All containers needing preservation are found to be in compliance with EPA recommendation? (HNO3, HzSO4, HCI<2; NaOH >9 Sulfide, NaOH>32 Cyanide) Exceptions: VOA, Coliform, TOC, Oil and Grease, DRO/8015 (water) DOC, LLHg (Yes T Yes Yes []NO [:]No ONO ❑N/A ❑NIA ONIA 13. Samples checked for dechlorization 16yes ONO []N/A 14. Headspace in VOA Vials (>5-6mm)? []Yes , ONO N/A 15. Trip Blank Present? Trip Blank Custody Seals Present? Pace TripBlank lot # (if purchased): ❑Yes ©Yes ❑No ONO N/A (fN/A !!!!! 16. CLIENT NOTIFICATION/RESOLUTION Field Data Required? []Yes []No Person Contacted: Date/Time; Comments/Resolution: Project Manager SCURF Review: _ Date: f Note: Whenever there Is a discrepancy affecting North Carolina compliance samples, a copy of this form will be sent to the / rth roltna DEHNR Certification Office (i.e. out of hold, Incorrect preservative, out of temp, Incorrect containers).