Loading...
HomeMy WebLinkAbout20061804 Ver 25_Stormwater Site Plans_20190220PLANNING: JOHNSTON COUNTY PLANNING DEPARTMENT. 309 E, MARKET STREET SMITHFIELD, NC 27577 CONTACT- MR. BRASTON NEWTON (919) 989-5150 BRASTON. NEWTON®I/OHNSTONNC. COM PUBLIC UTILITIES: JOHNSTON COUNTY PUBLIC U77L/77ES PO BOX 2263 309 E, MARKET STREET SMITHFIELD, NC 27577 CONTACT MRS CHANDRA FARMER (919) 209-8333 CHANDRA. FARMEROI/OHNSTONNC. COM NATURAL GAS PIEDMONT NATURAL GAS 250 FIVE POINTS ROAD DUDLEY, NC 28333 CONTACT MARCUS 7HOMPSON (919) 920-0257 ELECTRIC DUKE ENERGY P.O. BOX 1551 RALEIGH, N.C. 27602-1551 MR. JOHNNY HOUSE (919) 269-2548 JOHNNY.HOUSEODUKE-ENERGY. COM PUBLIX UTILITY AGENCIES WATER & SEWER: AQUA NORTH CAROLINA 202 MacKENAN COURT CARY, NORTH CAROLINA 27511 CONTACT PEGGY SUE DODGE (OFFICE) 919.653.6963 BRIAN HARRIS (FIELD) 919.624.2671 EROSION CONTROL: JOHNSTON COUNTY PUBLIC U71LI71ES PO BOX 2263 309 E. MARKET STREET SMITHFIELD, NC 27577 CONTACT JESSICA BATTEN, EI (919) 209-8333 JESSICA. BA T TEN®UGHNSTONNC. COM CHARLES PENDER (FIELD INSPECTOR) (919) 422-6725 CHARLES. PENDER®UGHNSTONNC. COM LOCATION: 4684 NC HWY 42, CLAYTON, NC FLOWERS PLANTATION JOHNSTON COUNTY, NC COUNTY: JOHNSTON PUBLIX AND ROADS IMPERVIOUS AREA -8.13 169900-32-0247 PIN: 1.23 Ac. DB/PG 05260/0236 ZONING: FLOWERS PLANTATION PUD ACREAGE 54.82 AC. SETBACKS: 6.28 Ac. FRONT YARD N/A SIDE YARD N/A REAR YARD N/A MAX BUILDING HEIGHT: N/A BUILDING DATA: PROPOSED USE: PUBLIX = ±48,387 Sq Ft RETAIL= ± 9,400 Sq Ft PARKING: RETAIL - HIGH TRAFFIC VOLUME: REQUIRED: 4 SP./1,000 SF GROSS PROVIDED: = 57,787 SF/250 SF = 231 SPACES REGULAR SPACES = 280 HC SPACE VAN ACCESIBLE = 6 HC SPACE REGULAR = 3 TOTAL SPACES = 289 EX. IMPERVIOUS AREA 0.00 Ac. PUBLIX AND ROADS IMPERVIOUS AREA -8.13 Ac. LOT 1 IMPERVIOUS AREA (85%) 1.23 Ac. LOT 2 IMPERVIOUS AREA (85%) 1.03 Ac. LOT 4 IMPERVIOUS AREA (85%) 0.76 Ac. LOT 5 IMPERVIOUS AREA (85%) 2.27 Ac. LOT 7 IMPERVIOUS AREA (85%) 6.28 Ac. TOTAL IMPERVIOUS AREA (851/6� 19.70 Ac DISTURBED AREA ± 19.05 Ac. Owner/Developer= Rebecca D. Flowers 4880 NC 42 East Clayton, NC 27520 919.553.3084 (v) Contact- Reid Stephenson INDEX g FLOWERS PLANTATION FLOWERS PLANTATION JOHNSTON COUNTY, NORTH CAROLINA RELEASED FOR PERMITS - FEBRUARY 8, 2018 COVER COVER SHEET CE -01 EXISTING CONDITIONS CE -02 SITE and UTILITY PLAN CE -03 GRADING PLAN CE -04 DRAINAGE PLAN CE -05 SOUTH FLOWERS PKWY. PLAN AND PROFILES CE -06 SOUTH MERCHANT AVE. and PUBLIX DRIVE PLAN AND PROFILES CE -07 E. MERCHANT AVE. PROFILES CE -08 WATER LINE "A" PROFILES and SEWER LINES "C" and "Dn PROFILES CE -09 SEWER LINE "Bn PROFILES CE -10 SEWER LINE "Bn PROFILES CONTINUED CE -11 STORMWATER POND DETAILS CE -12 EROSION and SEDIMENTATION CONTROL PLAN D-01 EROSION CONTROL NOTES AND DETAILS D-02 EROSION CONTROL NOTES AND DETAILS D-03 AQUA SEWER DETAILS D-04 AQUA WATER DETAILS D-05 REAR OF STORE UTILITY BLOW-UP D-06 CONSTRUCTION NOTES Civil Engin a ering= Stocks Engineering, PA 801 East Washington Street Nashville, North Carolina 27856 252.459.8196 (0 252.903.6891 (c) Contact- Mike Stocks, PE mato cks Asto cksengineering. com Surveying: True Line Surveying, P.C. 205 West Main St. Clayton, North Carolina 27520 919.359.0427 (v) Contact- Curk Lane, PLS curkstrueiinesurveying. com 1. TOPOGRAPHICAL DATA PERFORMED BY TRUE LINE SURVEYING. 2. THE CONTRACTOR SHALL NOTIFY AND COOPERATE WITH ALL UTILITY COMPANIES OF FIRMS HAVING FACILITIES ON OR ADJACENT TO THE SITE BEFORE DISTURBING, ALTERING, REMOVING, RELOCATING, ADJUSTING OR CONNECTING TO SAID FACILITIES. THE OWNER SHALL PAY ALL COSTS IN CONNECTION WITH ALTERATION OF OR RELOCATION OF ANY EXISTING FACILITIES. 3. ALL EXCAVATION IS UNCLASSIFIED AND SHALL INCLUDE ALL MATERIALS ENCOUNTERED. 4. ALL STRUCTURAL FILL MATERIAL SHALL BE FREE OF ALL STICKS, ROCKS, AND CLUMPS OF MUD. 5. UNUSABLE EXCAVATED MATERIALS AND ALL WASTE RESULTING FROM CLEARING AND GRUBBING SHALL BE DISPOSED OF OFF-SITE BY THE CONTRACTOR IN AN APPROVED SOLID WASTE LANDFILL. 6. THE PROPOSED BUILDING WILL BE SPRINKLED. USC APPROVED RPZ BACKFLOW PREVENTER TO BE LOCATED IN RISER ROOM, INSIDE BLDG. 7. THERE IS EXISTING UNDERGROUND WATER, SEWER, ELECTRICAL, OR FIBER OPTIC ON-SITE OR WITHIN CLOSE PROXIMITY. CONTRACTORS SHALL CALL 811 48 HOURS PRIOR TO DIGGING. CONTRACTORS SHALL DIG WITH EXTREME CAUTION. 8. CONCRETE SUB SHALL BE RESPONSIBLE FOR ALL SCORE JOINTS AND EXPANSION JOINTS. CONTRACTOR TO SUBMIT PROPOSED SCORE JOINT PLAN TO THE ENGINEER PRIOR TO POURING. 9. CONTRACTOR TO FURNISH ALL PAVEMENT MARKINGS AS SHOWN. 10. LOCATION OF UNDERGROUND UTILITIES ARE APPROXIMATE AND MUST BE FIELD VERIFIED. CONTACT THE NC ONE CALL CENTER AT LEAST 72 HOURS PRIOR TO DIGGING @ 811. TRUE LINE SURVEYING HAS ONLY LOCATED THE UTILITIES THAT ARE ABOVE GROUND AT THE TIME OF FIELD SURVEY. UNDERGROUND LINES SHOWN HEREON ARE APPROXIMATE OR AS REPORTED BY VARIOUS RESPONSIBLE PARTIES. THE SURVEYOR DOES NOT GUARANTEE THAT ANY UNDERGROUND STRUCTURES SUCH AS UTILITIES, TANKS AND PIPES ARE LOCATED HEREON. 11. ALL PIPE LENGTHS ARE HORIZONTAL DISTANCES AND ARE APPROXIMATE. 12. ALL WORK SHALL COMPLY WITH ALL APPLICABLE CODES, REGULATIONS, AND/OR LOCAL STANDARDS IMPOSED BY LOCAL UTILITY, NCDOT, JOHNSTON COUNTY, AND FLOWERS PLANTATION. 13. ALL CONSTRUCTION AND MATERIALS SHALL MEET JOHNSTON COUNTY, AQUA, AND NCDOT SPECIFICATIONS AND STANDARDS, LATEST EDITION. ALL WORK WITHIN NCDOT RIGHT-OF-WAY SHALL MEET THE SPECIFICATIONS AND STANDARDS OF NCDOT. 14. ALL CONCRETE PIPE IS TO BE ASTM C-76, CLASS III WITH RAM-NEK, UNLESS OTHERWISE NOTED. 15. THIS PROPERTY IS NOT LOCATED IN A FLOOD HAZARD ZONE. 16. WETLANDS AND PONDS ARE SHOWN. 17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK ZONE TRAFFIC CONTROL IN OR ADJACENT TO NCDOT RIGHT-OF-WAY. ALL SIGNS, PAVEMENT MARKINGS AND OTHER TRAFFIC CONTROL DEVICES SHALL CONFORM TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD), LATEST EDITION. 18. PRIOR TO PLACING CABC STONE BASE, THE CONTRACTOR SHOULD NOTIFY THE PROJECT ENGINEER TO INSPECT AND PROOF ROLL THE SUBGRADE. ANY STONE PLACED WITHOUT PRIOR APPROVAL WILL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 19. DESIGN/FIELD CONDITIONS QUITE EASILY MAY VARY FROM THAT REPRESENTED IN THE INITIAL SOILS REPORT AND/OR TOPOGRAPHICAL REPORT. ISOLATED AREAS MAY SHOW UP WEAK AND ADVERSE SOILS OR GROUNDWATER CONDITIONS MAY BE DISCOVERED THAT WERE NOT REVEALED DURING THE INITIAL SOILS INVESTIGATION. THEREFORE, THE OWNER/CLIENT IS TO BE AWARE THAT STOCKS ENGINEERING WILL NOT AND CANNOT BE HELD RESPONSIBLE FOR ANY FAILURES TO EITHER A STREET OR PARKING LOT PAVEMENT DESIGN UNLESS WE CAN BE FULLY AND TOTALLY INVOLVED IN THE CONSTRUCTION PROCESS WHICH MAY INCLUDE, BUT MAY NOT NECESSARILY BE LIMITED TO, TESTING SUBGRADE AND BASE DENSITY, ENGAGING THE DESIGN ENGINEER FOR THE EVALUATION OF THE SUBGRADE AND FOR THE OBSERVATION OF PROOF ROLLING SUBGRADE AND BASE AT VARIOUS STEPS OF CONSTRUCTION, OPPORTUNITY FOR THE DESIGN ENGINEER TO CALL IN A SOILS ENGINEER FOR CONSULTATION AND ADVICE, ETC. - STEPS WHICH TAKEN ALTOGETHER WITH THE INITIAL DESIGN SHOWN ON THE PLANS, CONSTITUTE THE COMPLETE DESIGN OF THE ROAD, STREET OF PARKING AREA (PRIVATE OR PUBLIC). THE DESIGN ENGINEER MUST BE GIVEN THE FULL LATITUDE AND OPPORTUNITY TO COMPLETE THE DESIGN BY FULLY PARTICIPATING IN THE CONSTRUCTION PROCESS. PLAN DESIGN IS A SMALL PORTION OF THE DESIGN AND CANNOT BE SEPARATED FROM THE CONSTRUCTION PROCESS IF THE OWNER'S/CLIENT'S DESIRE IS TO HAVE THE DESIGN ENGINEER STAND BEHIND THE COMPLETED DESIGNED PROJECT. 20. ALL UTILITY SERVICES, (POWER, TELEPHONE, CABLE, ETC.) ARE PROPOSED TO BE UNDERGROUND. DO NOT SOD, SEED OR MULCH DISTURBED AREAS UNTIL ALL UNDERGROUND UTILITIES HAVE BEEN INSTALLED. 21. SITE LIGHTING IS PRIVATELY OWNED. 22. PROPERTY IS TO BE SERVED BY AQUA (WATER & SEWER). 23. THE BUILDING SETBACK LINES SHOWN ON THIS PLAT ARE FOR THE ENGINEER'S USE IN ESTABLISHING MINIMUM LOT FRONTAGES AT THE SETBACK LINE AND FOR RESERVING SUFFICIENT BUILDING AREA. BUILDING CONTRACTORS ARE TO VERIFY LOT LINE SETBACKS BEFORE SETTING FORMS OR DIGGING FOOTINGS. THERE ARE NO AGENCY IMPOSED SETBACK LINES AT FLOWERS. 24. REGULATORY SIGNS, STOPS SIGNS AND ADA SIGNS SHALL BE MANUFACTURED FROM HIGH INTENSITY REFLECTIVE MATERIALS. FLOWERS PLANTATION HAS STANDARD BLACK POSTS AND SIGNS. CONTACT FLOWERS PLANTATION FOR DETAILS. 25. ALL EXCESS TOPSOIL AND UNCLASSIFIED EXCAVATION IS TO BE HAULED OFF-SITE, UNLESS OTHERWISE DIRECTED BY THE OWNER. 26. ALL SITE CONSTRUCTION MUST BE INSPECTED BY THE PROJECT ENGINEER AT THE FOLLOWING STAGES: A. COMPLETION OF GRADING SUBGRADE PRIOR TO PLACING STONE BASE. B. COMPLETION OF STONE PLACEMENT PRIOR TO PAVING. C. FINAL INSPECTION WHEN ALL WORK IS COMPLETE. 27. THE SURVEYOR DID NOT VISIBLY SEE ANY CEMETERIES IN ANY OPEN AREAS UNLESS OTHERWISE NOTED. 28. THIS PROPERTY DOES NOT DEPICT ENCUMBRANCES THAT ARE FOUND DURING A THOROUGH TITLE SEARCH. 29. ALL HVAC UNITS FOR THE PROPOSED BUILDING WILL BE SCREENED FROM PUBLIC RIGHT OF WAY. 30. ALL CURB AND GUTTER TO BE 24" STANDARD CURB AND GUTTER. ALL CURB AND GUTTER WITHIN NCDOT OR R/W SHALL BE 30" STANDARD. 31. ALL CURB AND GUTTER AND SIDEWALK CONCRETE IS TO BE MINIMUM 3,000 PSI AT 28 DAYS, AIR ENTRAINED. 32. ALL DIMENSIONS ARE TO FACE OF CURB UNLESS INDICATED OTHERWISE. 33. PROVIDE HANDICAP SIGNS, MARKING AND RAMPS AS SHOWN. 34. HANDICAP RAMPS ARE TO MEET "ADA ACCESSIBILITY GUIDELINES FOR BUILDINGS AND FACILITIES" AS DETAILED IN THE FEDERAL REGISTER, VOLUME 56, NUMBER 144 DATED JULY 26, 1991, RULES AND REGULATIONS ACTIVATED JANUARY 26, 1992. FOR ADDITIONAL INFORMATION, REFER TO THE NC STATE BUILDING CODE VOLUME 1-C, "MAKING BUILDINGS AND FACILITIES ACCESSIBLE TO THE USEABLE BY THE PHYSICALLY HANDICAPPED", 1991 EDITION. ALL STREET RETURNS TO HAVE H.C. RAMPS. H.C. RAMPS SHALL MEET CITY OF CLINTON AND NCDOT STANDARDS/SPECIFICATIONS. 35. CONTRACTOR SHALL NOT POUR ANY CONCRETE BEFORE FORMS ARE INSPECTED BY THE PROJECT ENGINEER AND/OR OWNER. ANY CONCRETE THAT HAS NOT BEEN APPROVED BY THE ENGINEER AND/OR OWNER WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. 30" STD. C&G 2" SF9.5A Behold, a virgin shall be with child, and shall bring forth a son, and they shall call his name Emmanuel, which being interpreted is, God with us. Matthew 1:23 30" STD. C&G BEFORE YOU DIG, CALL 800 NORTH CAROLINA &NE CALL CENTER www.ncocc.org 36.ALL AREAS NOT COVERED BY BUILDING OR PARKING SHALL BE COVERED WITH 4" MINIMUM OF TOPSOIL FREE OF ROOT MATTER AND ROCKS AND GRASSED. 37.CONTRACTOR SHALL SAW -CUT TO PROVIDE SMOOTH TRANSITIONS WHERE EXISTING ASPHALT AND/OR CURB AND GUTTER IS TO BE REMOVED. 38.THE CONTRACTOR SHALL PROVIDE ALL THE MATERIAL AND APPURTENANCES NECESSARY FOR THE COMPLETE INSTALLATION OF THE UTILITIES. ALL PIPE AND FITTINGS SHALL BE INSPECTED PRIOR TO BEING COVERED. 39.ALL HANDICAP SPACES ARE TO RECEIVE A HANDICAP SIGN AND HANDICAP SYMBOL PAINTED ON THE ASPHALT. NOTE STALLS TO RECEIVE'VAN ACCESSIBLE' SIGNAGE. 40.THE CONTRACTOR SHALL REFER TO THE ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND DIMENSIONS OF PRECISE BUILDING DIMENSIONS AND EXACT UTILITY ENTRANCE POINTS. 41.INFORMATION CONCERNING UNDERGROUND UTILITIES WAS OBTAINED FROM AVAILABLE RECORDS AND FIELD CONDITIONS WHEN POSSIBLE, BUT THE CONTRACTOR MUST DETERMINE THE EXACT LOCATION AND ELEVATION OF ALL EXISTING UTILITIES BY DIGGING TEST PITS BY HAND AT ALL UTILITY CROSSINGS WELL IN ADVANCE OF TRENCHING. IF THE CLEARANCES ARE LESS THAN SPECIFIED ON THE PLANS OR 12 INCHES, WHICH EVER IS LESS, CONTACT THE PROJECT ENGINEER PRIOR TO PROCEEDING WITH CONSTRUCTION. 42.THE CONTRACTOR SHALL INCLUDE IN HIS CONTRACT PRICE THE REMOVAL AND DISPOSAL OF ANY EXCESS TOPSOIL/UNCLASSIFIED HE DETERMINES IS NOT REQUIRED TO PERFORM THE FINAL GRADING AND LANDSCAPING OPERATION. 43.THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF ALL REQUIRED/NECESSARY SHEETING, SHORING, AND SPECIAL EXCAVATION MEASURES REQUIRED ON THE PROJECT TO MEET OSHA, FEDERAL, STATE AND LOCAL REGULATIONS PURSUANT TO THE INSTALLATION OF THE WORK INDICATED ON THE DRAWINGS. THE OWNER, SAMPSON COUNTY, CITY OF CLINTON & STOCKS ENGINEERING ACCEPT NO RESPONSIBILITY FOR THE DESIGN TO INSTALL SAID ITEMS. 44.THE CONTRACTOR SHALL INCLUDE IN THE CONTRACT PRICE DAILY RECORD KEEPING OF THE AS -BUILT CONDITION OF ALL OF THE UNDERGROUND UTILITIES, CONSTRUCTION STAKEOUT ASSOCIATED WITH THE PROJECT. 45.ALL WATER LINE AND SEWER LINE INSTALLATION SHALL CONFORM TO THE STANDARDS AND DETAILS OF THE STATE OF NORTH CAROLINA DEPARTMENT OF HEALTH CONSTRUCTION PERMIT, JOHNSTON COUNTY AND/OR AQUA. 46.ASPHALT PAVEMENT SHALL BE SMOOTH, WITH STRAIGHT OVERLAPPING SEAMS, FREE OF SEGREGATION, STAINS, BIRD BATHS, AND IMPERFECTIONS. ASPHALT PATCHING, SKIN PATCHES, OR RE -HEATING AND ROLLING WILL NOT BE ALLOWED. AREAS THAT ARE NOT ACCEPTABLE TO THE OWNER/ENGINEER WILL BE SAWCUT AND REMOVED. NO PATCH SMALLER THAN 200 SF WILL ALLOWED AND THE SAWCUTS MUST FALL ON A PAINT LINE OR EXISTING SEAM. 47.THE CONTRACTOR SHALL INCLUDE IN THE CONTRACT PRICE ALL MATERIAL AND LABOR ASSOCIATED WITH THE TESTING OF THE WATER AND SEWER LINES REQUIRED BY THE STATE OF NORTH CAROLINA DEPARTMENT OF HEALTH & AQUA. 48.THE CONTRACTOR SHALL INCLUDE IN THE CONTRACT PRICE ANY DE -WATERING NECESSARY TO CONSTRUCT THE PROJECT AS SHOWN ON THE PLANS. 49.NATURAL GAS IS AVAILABLE. COORDINATE INSTALLATION WITH PEIDMONT NATURAL GAS. 50.TESTING BY CONTRACTOR: CONTRACTOR SHALL EMPLOY AT HIS EXPENSE AN OUTSIDE INDEPENDENT SOIL TESTING SERVICE (APPROVED BY THE OWNER) TO PERFORM SOIL TESTING AND INSPECTION SERVICE FOR QUALITY CONTROL TESTING DURING EARTHWORK OPERATIONS. COPIES OF RESULTS OF TESTS SHALL BE SUBMITTED BY THE TESTING SERVICE DIRECTLY TO THE CONTRACTOR, THE OWNER, AND THE STRUCTURAL ENGINEER. --THE TESTING SERVICE WILL CLASSIFY PROPOSED ON-SITE AND BORROW SOILS TO VERIFY THAT SOILS COMPLY WITH SPECIFIED REQUIREMENTS AND TO PERFORM REQUIRED FIELD AND LABORATORY TESTING. (MINIMUM REQUIRED SOIL BEARING CAPACITY IS NOTED ON THE STRUCTURAL DRAWINGS). --IN PAVED AND BUILDING SLAB AREAS, THE TESTING SERVICE SHALL MAKE AT LEAST ONE FIELD DENSITY TEST FOR EACH 2000 SQUARE FEET OF FILL IN EACH COMPACTED FILL LAYER. IF A TEST SHOULD FAIL TO MEET REQUIRED DENSITY, THE CONTRACTOR SHALL RE -COMPACT THAT LAYER. THE SOIL TESTING SERVICE SHALL PERFORM ADDITIONAL TESTS AT THE CONTRACTOR'S EXPENSE TO SHOW THAT THE FAILED LAYER HAS REACHED THE REQUIRED COMPACTION. --IN FOUNDATION WALL AREAS, THE TESTING SERVICE SHALL MAKE AT LEAST ONE FIELD DENSITY TEST FOR EACH 100 FEET OR LESS OF WALL LENGTH OF FILL IN EACH COMPACTED FILL LAYER, WITH NO LESS THAN TWO TESTS ALONG A WALL FACE. IF A TEST SHOULD FAIL TO MEET REQUIRED DENSITY, THE CONTRACTOR SHALL RE -COMPACT THAT LAYER. THE SOIL TESTING SERVICE SHALL PERFORM ADDITIONAL TESTS AT THE CONTRACTOR'S EXPENSE TO SHOW THAT THE FAILED LAYER HAS REACHED THE REQUIRED COMPACTION. 51.COMPACTION: COMPACT EACH LAYER OF BACKFILL AND FILL SOIL MATERIALS AND THE TOP 12" OF SUBGRADE IN CUT AREAS TO 98% OF MAXIMUM DENSITY AS DETERMINED BY ASTM D698 FOR STRUCTURES, SLABS, AND PAVEMENTS AND 90% OF MAXIMUM DENSITY FOR LAWNS OR UNPAVED AREAS. 52.THE BUILDING CONTRACTOR AND THE SITE WORK CONTRACTOR ARE TO COORDINATE THE INSTALLATION OF DRAINAGE PIPES AROUND THE BUILDING STRUCTURE. 53.ANY RELOCATION OF EXISTING UTILITIES WILL BE AT THE COST OF THE OWNER. THE WILL NOTACCEPT RESPONSIBILITY FOR DAMAGES TO CURB AND GUTTER OR STREET IMPROVEMENTS INSTALLED PRIOR TO UNDERGROUND SERVICES, NOR WILL THE CITY ABSORB THE COST FOR BORINGS TO INSTALL UNDERGROUND SERVICE, PAVEMENT PATCHING OR DAMAGE TO LANDSCAPING. THESE WILL BE THE RESPONSIBILITY OF THE DEVELOPER/OWNER. 54.FIRE DEPARTMENT VEHICULAR ACCESS TO ALL STRUCTURES UNDER CONSTRUCTION SHALL BE PROVIDED AT ALL TIMES. IN AREAS WHERE GROUND SURFACES ARE SOFT OR LIKELY TO BECOME SOFT, HARD ALL WEATHER SURFACE ROADS SHALL BE PROVIDED AND MAINTAINED. 55.ADDRESS NUMBERS, BOTH COMMERCIAL AND RESIDENTIAL, MUST BE POSTED ON THE FRONT OF THE STRUCTURE NEAREST TO THE MAIN ENTRANCE IN A POSITION TO BE PLAINLY LEGIBLE, VISIBLE, AND UNOBSTRUCTED FROM THE STREET OR ROAD FRONTING THE PROPERTY. 56.DISTURBED AREA IS OVER 1 ACRE AND A FORMAL SEDIMENTATION & EROSION CONTROL PLAN APPROVAL IS REQUIRED AS A CONDITION OF CONSTRUCTION PLAN APPROVAL. THE SEDIMENTATION & EROSION CONTROL PLAN PROVIDED SHOULD BE REGARDED AS MINIMUM REQUIREMENTS; ADDITIONAL MEASURES SHALL BE PUT IN PLACE AS NEEDED TO ENSURE THAT NO SEDIMENT IS RELEASED FROM THE SITE. 57.(CONSTRUCTION/SITE PLANS) WATER AND SEWER PERMIT APPLICATIONS HAVE BEEN APPROVED BY THE DENR. PERMIT NUMBERS ARE AS FOLLOWS: WATER PERMIT NUMBER: NOT REQUIRED SEWER PERMIT NUMBER: NOT REQUIRED 58.COPIES OF ALL PERMITS AND APPROVED PLANS MUST BE KEPT ON SITE IN A PERMIT BOX THAT IS CONSPICUOUSLY LOCATED AND EASILY ACCESSIBLE DURING CONSTRUCTION. THIS INCLUDES APPROVED CONSTRUCTION PLANS, APPROVED EROSION CONTROL PLANS, ENCROACHMENT AGREEMENTS, DRIVEWAY PERMITS, WATER/SEWER PERMITS, ETC. 59.ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL NCDOT, JOHNSTON COUNTY, AQUA AND NCDENR STANDARDS AND SPECIFICATIONS. 60.MAINTAIN MINIMUM 3' COVER FOR ALL WATER PIPE. 61.WHERE WATERLINE CROSSES: A. SANITARY SEWER: WATERLINE SHALL CROSS ABOVE AND MAINTAIN 2' VERTICAL SEPARATION OR 10' OF HORIZONTAL SEPARATION. IF THIS SEPARATION CANNOT MAINTAIN OR IF WATERLINE PASSES BELOW SEWER LINE THEN BOTH WATERLINE AND SEWER LINE SHALL BE CLASS 50 DUCTILE IRON PIPE FOR A MINIMUM OF 10' EACH SIDE OF CROSSING. B. STORM SEWER: WHERE WATERLINE CROSSES ABOVE MAINTAIN V VERTICAL SEPARATION, WHERE WATERLINE CROSSES BELOW MAINTAIN 2' VERTICAL SEPARATION. IF THIS SEPARATION CANNOT BE MAINTAINED WATERLINE SHALL BE CLASS 50 DUCTILE IRON PIPE FOR MINIMUM OF 10' EACH SIDE OF CROSSING. 62.WHERE SANITARY SEWER CROSSES STORM MAINTAIN 2' SEPARATION. IF THIS SEPARATION CANNOT BE MAINTAINED SANITARY SEWER SHALL BE CLASS 50 DUCTILE IRON PIPE FOR MINIMUM OF 10' EACH SIDE OF CROSSING. 63.REFERENCE NC 15A, 18C, .0906 FOR ADDITIONAL CROSSING INFORMATION. THIS CRITERIA SHALL BE MET AT ALL CROSSINGS. 63. REFERENCE NC 15A, 18C, .0906 FOR ADDITIONAL CROSSING INFORMATION. THIS CRITERIA SHALL BE MET AT ALL CROSSINGS. 2" SF9.5A street cress sectloffs NOT TO SCALE orn �00 xl O M LO C5^ N 0 u7 N w Z O a_ 0 z i W~ w LL, LU QfF- z 0 L z00 �(0 Z N M = U Z z ~ LSI J W 0 w= I= 0000 Z O U 0 Z 0f w w z z w Cn Y U O H 4z . SEAL 19843 Z91AEL S�OG • ,, �I�IQI 111 �/� 2/8/19 COVER SHEET REVISIONS FILE NO. 2018-033 HORZ. SCALE: NONE VERT. SCALE: NONE COVER a I °.. ° ..-�p^� rs..e-. ✓ /... - ✓ .... II.. OO - Z \ _ 4• CON / II I� — / / �. / F / II 1 Q- 11/ MH5311 T OF—WAY RIGH------_-M6n1ZED SS -53 m x T R,w I _ /; %____= 6%=„� ==- ___- - - \ \ \ --__- - AKE LI 42 No co Ln l / / // /< � \ Ei I \� I I o .� I —' —_�� Ex R,w 1 \✓/ I I I I I ! 1 1 \ 1 \ \\ \ \ 1 \�� \ \ _— -- // \ \ 1 IVII WAY ��/ / / l l I I I I I / II 1 \\ \\ \\ \ \ \\ \\ \ \\ \ \\ \\ \\\ \\ \ \ \ 1 RIGHT OF— 13'oj 305 \ \ wlo 300 \ 0/ — — — — ----_ \\-- \\\\\_ --- __ ----/l I \I l j i 1 � r/, / F// / /• � /I � I 11 11 1\ .� \\ \ �\ \ \ \ � \ 1 / / // //.. // //✓ \\\ \\\ \\\\ \\\ \\ \ \ I \ \ \ \ \ \ \ g0' \� \\ \\\ \\ \\ I I 1 / ' 1 I I j // // /e / / w°eIV "2R�N\ �0 G �C\ \ \ \ \ �s�, IN 295 \ \\ \ \\ \ \ \ \ \ \ \ —) \\\ \I \ \\\�_'/ \\�-------285—__ / \ I I 1 I I \ \ \\ \\ — — — — \ \\ I �/ \ \ L e \ \ \ \ \ o \ I \ / / \ \ -- --e \ \ I I r \®\ \ \ I I I ► I 1 \ \ , \\ ./---_\ \_ tee\_ \\ \—_ __—' ,,----- \\ ' FIELD- 280------/ \\\------------------- 285 CID \ \ \ \ \ \ �\ \ � _ \ � / / / \// III \ / // // /� / / i _✓ - \ \ e \ \ \ 1 I I \ \ \\ e \ \\ \ \ \ \ \ \ V. 6 \ '\\ - / / I 1 / /---- / \ / / / 1 ✓ ./. ZN I I \ O \ \ \ \ \ \ o t— \ \\ \ \ ^� \ \\ //// / l / / Q0�5-\✓/ lL\\ // / // I / / — /�� // / - /&CANP- -,- >j) LI Imo, \ \ \ \ \ \ \ OS—TING\ \ p roN, \ \ \ \ \\\ \ \ \ \ \\ \ \ \ \\ 280—\� \ \\ \\Q�\ \ \ \ \ \ �\ = \ \ \ \ \ \ — \ \ \ \ \ \ 5 \ \ \ \ \ \ \ \ \\ \\ \\ \\ \\\\\\\ \\\\\ \\ \ SCALE: 1 60 0 60 120 150 180 210 240 AND THE ANGEL SAID TO THEM, "FEAR NOT: FOR BEHOLD, I BRING YOU GOOD TIDINGS OF GREAT JOY, WHICH SHALL BE TO ALL PEOPLE. FOR UNTO YOU IS BORN THIS DAY IN THE CITY OF DAVID A SAVIOR, WHO IS CHRIST THE LORD. LUKE 2: 10-11 • orn �00 x1 O m `n N 0 N w z O V Ld w w z_ Zz w cn Y U O W w3: W� U)z Z c0 O 00 00 Z N U (n= � Z Z Vw (n J_ Ww= 0000 z BLN=C-1874 \ \01%A111 \, CARO,I�'I Q SEAL < 19843 0/1AEL S���� . lc�aeA e 2/1 /19 EX/ST/NG CONDMONS REVISIONS FILE NO. 2018-033 HORZ. SCALE: 1"=60' VERT. SCALE: NONE CE -01 \... f _ + M.H. N TOP 299.1 Z IN 291.51 CONC / OUT 289.42 4' LL_ P OPLZED I{ I __--- -- — _-------______= 12 _W — _ F 6 DRY 53 m SI N CTIO __-- - _ _______________ _-W— `f 0 AND JA �E_== _ _ s - / / \ SS- , r Rs -_ -_ _ -- S ,-- _moo%�_ - _ / _ \-- / / LI pIP �A R _ _ ;�_ �� �/ ✓ / ' — —� - — — - / / / A K E \ �5- 10+0 I ER + � � � c ---- ---- ----- �__-� �= R �—Vol- No\ _— — \ MONOLITHIC - I hs-�ro+" �SIGN s\\\� IA or FlfJUFE S o __--__--- FM%' _— � ��� EXIST R/ 1 \ I — 24" pRY BORL 5 24" bylD , c= _ \ %� - = RI f f I-OF-wA \ > — J / i N I I / SI ON ROM IBAR -55 LFI 0 W 12 ]Qt0 / - - JACK PIPE. -..- � � _ _ - — — - "� I ED RIGH OF RR T- cA. oSCP ___;� C \pS l 1 1 I I Is \ \ \ LLOWLASTic � \ \\ _-�� \\\ — ' / I I I \ 1 �R/W \\\ \ �� \\\1 i TFW I \ 40 v v \ \ -vA E313 Rt �'--z v TC T DEPRESS TC/ D 1 \�\ \��� 0 \\\1 \\��� �� — — / // / 0^'1 - + 4/" -SOLID WHITS STRIPE (THERMO) — L� \ 4" MINI -SKIP (THERMO) .�- r��%� _ — — ! — — _ _ / \ \ 1 c I \ / / / / I I I I I �, \ \ \ \ ♦ \ ' \ \ \ \ // �_--295---__-- It# I \\ / /' L��j't'—' 11112' 1' 12'112 10 --------- \\ \_ I 22 1 +,D �1 I / / l I (f ,i / cnT I o 10 �I 9°' R/W __--- __----__ 1 — � _ _2'`1 I o. -+I �� � 11 ; //.F // / % / 1 � 11 1 \\\\• \\ \ I 22T - I 1 1,`�' / / 1 1 1 / / y / / / I I \ \ \ \ \ ♦ \ \ \ \ \ SIDEWALK , — — — — _ 22' I / / I / �w / / / 1 \ \ `�, \ \ \ ♦ \ \ \ BEGIN LOWER WATERLINE/TO A[7EL �0 /CT S \ \ \ \ \ \ \ / ELEV. 28.0 1 \ 24" ME�IA�PI-6l}RB-- — — _ _ _ � � � 22' � _ � � — `S \ / / I 1 0 1 DIREeTIONAL ARROW _ / / 1 \\ \ I / / I \ I / / / / 1 \ \ \ \ \ �0 \ 4" S06D n I I ERMO ~ 2\ _ \ \ \ / M / I I 1 / WHV/E STRIPE 1 `' (Tial ) (TYPICAL) 24" WIDE — — — — _ \ — FR U) FIRE I / I 1 c� / \ AP4SITION {o �" I / / (THERMO) D I 80 LF 6" SDR 35 / STOP BAR / _ \ \ E�pER�OR6 _ \ } v HYD / / I I j / / O ) \ \ / I 1 "VC C.O.STOP±292RJ0 (THERMO)// \�� �� �\ \ \"�-�" �' C&G 1 O \�� 11 II l Mod f2so.ss V w 1 cn +I INV. 2825•i'• / 1 � � 6"ILOT#1 /NV. 279.85 1 WOR / 2" WATER \ \ / 6t LOT#2 /NV. 280.85 1 _ — STOP O SERVICE I \\ lryv. our 279.35 I'd 1 / C.O. TOP' ±29250 ' Q1 24" _ - \ \ \ :: ' , • II \ \ ♦ qo\ II \I \ \ \ \ \\ \ \ \ 1 \ \ `'' 1 \ 2 R I / Ql STD. C&G ! INV. 281.10 - — •� •- *,; 1 I SITI F M HEADER;'� _ 1 \ 1 \ \� \ \ \ \ \ \ r \\\ 60 LF 6" AOR 35 TRAB to 30~ 1 \ ,PvCss. X2.089 , I \ wcR 10 U,:::. 1�1� •. / 30 88 \ i I i \I / / / / // \\ /-,\ \\ \\ \\ \\\\ T/LUC EASM'T \ \N I I I I / / / /' FUTUNTIA'L RE / �\ / / I / I I 1 ` RESIDE BEH# D SIDEWALKR 1 , J 1 \ \ \ ' 12" c -s 0 \ T+ , l ANSI`r > \ PVC WATER o� C&G TOS FROM 30'ig�`D END LOWER \ 2 WATERLINE 1 \ S•�EEP RIGHT SECTION To �, \ SlG(V II 3sd ��\ / \ \ \ \ LOT T� • \\ \ \\�\ \ \ \ \ \ \ \ \ AVOID CONFJ Tx\ //�� \ \ \ \ \ \ \ \\ / 18" OAV/ \\ \ \\ x\\ \ / MEDIAN \ I t •Q3 \`�� 9 • --- \ > \ \ �, 4.' SOLID s\ 1 + \ \ •• — — — — 285 � _ ' , / / � �\ / / I \ \ �. + 3 to \ I WH/TE STRIFT \ 1 \\\I \\ I �(THERMO)y�ILLTY 4" lNl-SKIP — _ 0 °b _ N \\ \\ \\\ \\ \\ \ \ \ (T RM0) RETANING WALL \� \\ `� oNCDOT , \ \ l \\ \` o\\ / \\ ffff �QNSITION FROM o n — — _ — — ` \ \ \\ \ } \ \ (SEE DETAIL) \ I O J / / \ — \ c \ \ \ — �. p STANDARD � I l �. HEADEl72`"QRB to � I \ M.H. #8 \ \ \\ 1 ♦ \ \� \ \ / )TOP ±2�1.00I �GAUfiDRAFlR€ 1 \ b I � .. � e 30" C&G \ \ \ INV OUTI28110 — / \ \ -- \ HYD �� . l .. � '. �f1P••± _ — / � � � _ \ _ -w � � \ti $5 / \\ \ V A I A\ 20 Lf� DRY BORE 1�� _ _ 278.82 �`� / \V A \ \ I \\VAA AND/JACK\ 1$ 1 \. �� Ou-r \ \ \ \ ♦ \ ENCASEMENT & / \ \ +� $ \ n c� 1 \ — — _ __ - `STOP \ \ \ \ \ \\ \ ♦ \ \ \ I 8" flP CARRIER MOP 82.00 \ \ \ ` 2 1/2 ' o 0 0 \ 0' \ _ \ SIGN PSP \ 1— e \ ` =--�— INV. IN 275.85 INV. OUT 275.65 \ L \ •, \ , — \ \ / ao o ` _ — — ' _ / 1 \ \ \ I 1 \I \ \ \ c9� �\ l / \ * — \ \ \ — _ i SSP �/ FIRE \ \ \ \ \ \♦ k r� oo\� RETAINING WALL \ \ \ — / — — VC ER — —� '9 — _/ \ %, HYD \ \ \ \ ♦ \ OL\ I (SEE DETAIL \ \ \ — „� \� C- ?0 _ \ / i /- � \ \ \\ \ \�v���I 1 \ / \\\ —_M 3\— W �� / TPI' �� \\ / / / 1 `yl\ I\I N\ \ \ \ \ \ \ 1 \I N I 1 \ / \ \ rP�� �\ \ \ 1 ♦ \ / \ I--- -� V- IAL 269.03 (#4� \ \ \ �\ I 1♦ \ �y\ \ \ 5 \\ I \ 4'�s INV. IN 267.'23 (#5)�� 40'R / INV. OUT 267.03 c \ / / / \ \ \ \ \ \ \ \ \ \\\ \ \ \ \ \ ®. �6�,LF8"CL 50 \ \ \ moo\ 67AC' \ \ \\ �� \, DIP S. S. ®ao� ra STP V% V Milo \ �?\\ \ ♦ \ o moo\ 3 \ \ \ \ \ ��e� •cP'oo // -280-- /� � \ %\ \\ \ o\`\ s\ \ \\ \\\ \\ SX�7EAING M TTEMAIN \\\\\ �( '/\kX \ s\ �q \\ �� \ \ \ \�\\\\ ♦ ow\ \\ ~\\ \�� \ \ (DgNOT DIS l�/RB) \ \\ \tea �\ \\�--------__ \ \\ '/ _— \�\ ASEME Tom/ �✓ / / / / \ \/ \\ \ 11 \ \ \ TION OA / \ b / . � \ I 1 I \ \�\ ♦ \ \ \\ \\ \ \ \ \ /----___BM%� 4\Gp8 \ 1 \ I\ \ �\\� \ ♦sem \ \----285---__ \\\ \\ \\ \I 1\ \ ,Re�����\�� _a ;�J _---275-- 15'pE\ \\ ,_---_---' h /—/�!\/ \ \ \ 1 \ o \ \ T — \-----_--� / /' /�' /' \ \ \ \� \ ♦ o: \ \ \ \ \ TOP ±�7i \� 9 R — __ _ /-/- �' � —\ \ .�'—sem _ / \ \ \ \ \ ♦ '<< o; s r: �— — — — — — \ \ \ \ \ y�pFFt / / \ INV.\lN X268.35, 1 \ \ \ � \ \ ` s ; >°. � _ \ � _ \ \ � � ' — —_— �� / / J' INV. UT is8.15. \ �� _ 6y / _ �� / / \ \ / V \ \ \ 8" oir \ \ \ \ ♦ c� (P,/0 \ \ \ \ \ \ \ \\ �� �� �`�G lip — �. C±2669.06, ♦ /o P �G ,>lti / \ \ \ \ \ \ \ ? 71VU�.(�V• 257.30 f % \ \ INV. O 57 1 /. If x 0- \ \ a \ ♦ 9 FIRE //Pg� / S \ \ \ \\ \\ \ \ \ \ \ �\�\ \:\ \\\ \ / / / / // / \ / Site LeI\ \\ \ \ .-✓- \ STOP \ —��\ y/ m IGN EX. CURB & GUTTER \ \\ 5 ♦ \ %\ \ \ \ \ \ \ \ h \ \ \ \ \ \\� _ ----------- . EX. DRAINAGE \ \, \\ \\\ \.�, mss_ // / r\\\ \ \ \ \ \\ \ \ / \\ \ �\ \o �\ \ \\ \ \\\ �\\\� �\ 2 l��\\� _--�===_ /� // / I / / //---�---✓ \A' --*L ---- 4Y EX. WATER LINE \\ k A / L \ \\ \ \ \ O \ �� �b _ __\ / __ /j / r \ \ // --FM----FtF EX. FORCE MAIN ♦♦ o (P/0 /�/f,' i \\ \' \ \ \ \ \ \ \ \ �� �\ \\/' 2 \,, // \ — / % / ��, /� —__ _mac \ \ / / // //• / •.•�/.\\J. EX. WOODS LINE \ `� j I I o \ \ \ \ \ \ o t� \ \ \ I sIf R I \ \ \ I 1 �/ Oslo / 1 / / <0 / / - EX. WETLANDS (DO NOT DISTURB) \ I I ♦ \ / / / / / I I I \ \ \ \ \ \ \ \ \ \\ / — \ \ \ �\ — — — — PRO. DRAINAGE PIPES & CATCH BASINS NCDOT TYPE 111 l I \ \ \ \ \ \ \�ti \/// I BARRICADE l I 1 \ \ \ \ \ \ \ \ \ F \� \ \/�/2Oy, \ I / ♦ \ � • �`` \\ l IIII �_ \ TOP/±258.00' — / EX. /M. H. / / // PRO. WATER, VALVE \ I \ I ♦ � � \ ♦♦t 1 I /' I \ \may \\ \ ��\ \ \ \ \ \\ \\ \ \�T \\\ \� \ \\\ �� jll�` �� �_�� JNA! IN 240 o EX. TOP 253.95\ FIRE HYD., BLOCKING, etc. \ I \I ♦ i'`o\ \ v\ \ I / I 1 \ \ \ \ \ \ \ \ \ \ \ \ \ \\ \ �. \ \ �� i / �� _� INV. OUT 48.98 / EX.I IN 245.50/ PRO. SEWER &MANHOLES \ \ \ \ \ \ \ \ \ \ \ \ \ \ \\ \ \ _ _ _ _� _ \ J ER OUT 244 23 \\ I \\ \ I �� v \ \\ \ \ \\ \ \ \ \ \ \� e _ <-- -- \ /lN 245.0 \ \ \ 16 x \ \ I \ / \ ♦� \ \ 1 �\ // \ \ \ \� �� �\ \ \ \ �\ \ �\ \ \ \ \\ \ �� Y \ \ /\ STA PRO. CENTERLINE ROAD \ \ \ \ \ PRO. SIDEWALK \ \ \ I I \ \ \ \ \�` \ \ �� �� \ \ )- \ \\ \ y\ \ \ \ �\ e. // \ \ �� \ \ \ \� \\ \ \\\\ PRO. CURB & GUTTER (30')\�--\`—_L--, \ I / \_� i -- PRO. PROPERTY LINE \\ \ \ \ \ ♦\ \ F \\ \ \\ \ --___® \ \ \ \ �� \\ \\ \\ \ \ \ \ \ \ \ \ \� \ // /--� \ \ \ \ \ 27 \ \ \ \ \ \ -28 _ \ 0 \ SCALE; 1' = 60' \ \ \ ♦ \ . \ \ \ \ X27 \ \ \ \ N6&1 0 60 120 150 180 210 240 \ AND THE ANGEL SAID TO THEM, "FEAR NOT: FOR BEHOLD, I BRING YOU GOOD TIDINGS OF GREAT JOY, WHICH SHALL BE TO ALL PEOPLE. FOR UNTO YOU IS BORN THIS DAY IN THE CITY OF DAVID A SAVIOR, WHO IS CHRIST THE LORD. LUKE 2: 10-11 O m 00 XI O m LO O^ N m LO CV w z O w w w z Zz w cn Y U O WLLILLI 3: cr- WU Z Z(D O LQ �00 � Z N z (n= � Z z �w () J W w> Goo Z BLN=C-1874 �. CARO" Q SEAL < 19843 UINt- % "ChAEL S'���� �'2/1/19 SITE and UTILITY PLAN REVISIONS FILE NO. 2018-033 HORZ. SCALE: 1"=60' VERT. SCALE: NONE CE -02 t M.H. N TOP 299.1 Z IN 291.51 / OUT 289.42 4° MH53 ED 11 _---__ __-- \ _ I _� _ — _ _� - �___ ___ — — j P1 N LIZED % 1 __-- ---_ ` � %T \ \-------- I6 LTI Z E D S — — ' — ss -53 m I T RS CT10 - -- _ ---- - ®-'sr 1-,\� _ - - _ ! / \ \ �_- - \ _ AKE L I\ 42 _o co 1 ��/ /' \ �• \I 2991 10+00• -___ - - - \_�_- / I I I rc 6 \ \ \ \ �\\ 9Q \\ � I l\ l I \\\�\`\ \ \ � \ \p \ • � / \ \ \. T rC / PTC �3. 1 \ + \ \ \ \ \ \ \ \ \ \\\ \ 1 Tt\ \ \ l —�O '�"� �\ '' ... 2.4•'`8 \ "` p 2 2 1 \ \ �r \.. \ —� \ \\\ \�\ \ I 29 p 2 1 \\ \ \ \\ \ \ \ \ \\\ \ \ \ \ \ \ \ \ \ \ \ \ \ \ - �_ � _c_ ---> / �\ I I 2 \ 74 �29� T 29z• L --L I ? 1 1 I 1 \�\ \ \ \ `\ \\ \ \\ \\\ / \ ♦ - A � � —� �-- / / /' /' � � � Ali I rc 2. s2 / / / / I � 1 ,.. _ �� v v v v 'C ♦ 2• / / I 1 I \ \ \ \ \ \ ✓\ \ \\ //290 \ / / , -_ --295----_-_ -- 28 • - -- / 9 �. � \ / / / 1 / I I 1 \ \ i \ I-- -_`\ •7 T - _\ - c __ r 28 • _ / 2$ ,..,\ \ I 1 \\ � / // / / / / I i I , ,\\�U\\�\\ \ \ i \ \ \ \ \ \ \ \ X/ co I I _ ------ -- - -- \\ ,' /woo /-__ --_--_ - \ \\ _-__ ----- _ 290 1 // / � 11 11 \\\\ \\\\ � ♦ \ I \ \ \ \ 4�6 4 a \ Yg Tc -Te 1 1 / oI � 1 \ - 'C,.29 � \ \ \ \ I I I I / / /' / I / \ \ \ `�\`�' �, � FG ♦ \ \ \ \ \ \ \ 291 / 9 o/ T .02 _ \ _ 290 42 _ 291. a \ \ \ \ � I '• P T = 291.N _ 291 2 1 I \ \ \ } \ \ \ \ \ \ \ \ \ P- IN Apu \`' � / _ N. � 2/ � 280 / ,e / `\ � / / h \\\\\\ pEVELOPN►ENT \\ �yZ? � 1 \ \ \ \ \ \ HP TC 000 X8.10 +Aco ��• \ \\ \\\ \ 1 \ \ \ o. \ \2so.9a. \ � � // \ _____ _ I\ -- - _ - 1 \ _-- \ \ N \ 1 T 287.50 282 \I\ ♦ \ \ ` TdW 0.5 , \Lc— cmc y 86.56 ♦ \2 - A \ 1 1 \\ ��\ A \ \\ \\ \ \\\ \ \\ ♦ \ i I / / // �\ \ 4s 289 \ ; / 200 rc 2s8- 1 v 2�� � - _ \ / l \. \ T 4 �89•Oi— Z 53--- \ \ \ �(� ` I (� \ L \ `*, roh c• • \\ \ \ o ks, / \, ISN \ 4 _P _ \ \ \ I 1 \ \ \ \ \ ♦♦ TC \ 2 a74 1y)'j\\ �\ \ \ 1 ♦ � l � I -. ��SP1 ,Xyk \ / .,,.- ..,--- - `e_ `---/ l / 1 / I \ l\' \ / \ \ \\ Tw\R8.16 o \ \ \ \ \� \ \\ ♦ s \ �. t-2,8 \ \\\\\ \\ \ \ ♦\ x\� \ '3 \ \ \\ \ � \ `e..�P, / ----280-- - -' /--- -` -s._\ _ \` \ / I I\ 1\1\� / \ \ \ \ \ \ \ \ \ \ \ \ \ \ EXISTING IN\TLANDS S�7EAM TOiZEMAIN 7�8// \ \ �� \ \ \ \�� \\\ \ ♦ �� \\ \ \ \ (D NOT DIS RB) \ \ %8 \ \\ \ 1 I � \ ♦ \%\, \ o \ 1 1 \ \ `�\ ♦ \ --_ \ \ `\ \ �, \ \\�-- \��_1\_`-----_ ' 267 \\ \�>\\\\I I l I\ � // � ` -- \ 1 1 1 \ -'' \ ♦ sem, �\ \ ` \ 1 p. \ —— �'i"`✓' �/\ / �/ 1 / -- \ \ k -285-- \- del \ \ % QQ \\ \\ \ ♦ h \ � --i-; '' �---__ �' �, 1 1/ \- h \/� \ \ \ ♦ �pk°°co / '' / l / �•Zi��i ii• I I I I \ ^ \ \ �'� \ \ \\ \\\ \ \\ \ \i��-. _ --�\ ��G ��— —`/ � O /\/ / - � - % - � � I I � I \ \ \ zz- 1 \ I \ \ \ \ \ \ \ \`\ \ \ \ \ \ \\ \\ \ \ \\ / --28Q—_—_—_ — \ \ \\ \ 2 0 'Dss\ SCALE; 1' = 60' `� \ \ \\\ ♦♦ ` �.. / _ \ \\ �\ `\ `�� 27 0 60 120 150 180 210 240 AND TF\ A=AID TO THEM, "FEAR NOT: FOR BEHOLD, I BRING YOU GOOD TIDINGS OF GREAT JOY, WHICH SHALL BE TO ALL PEOPLE. \ F TO YOU IS BORN THIS DAY IN THE CITY OF DAVID A SAVIOR, WHO IS CHRIST THE LORD. LUKE 2: 10-11 00 Lo O m 00 XI O rn m `o N 0 Lo CV w z O V � w w z_ Z U z w cn Y U O H WLLILLI 3: cr- W� z Z (O O LQ 00 z (N = U z z �w () J Ww > 0 00 z BLN=C-1874 ,111 ,I CARO p�'I Q SEAL < 19843 IVC I 4''1/1AEL S� ��� . lceA e 2/1/19 cj���� GRADING PLAN REVISIONS FILE NO. 2018-033 HORZ. SCALE: 1"=60' VERT. SCALE: NONE CE -03 t M.H. N TOP 299.1 Z IN 291.51 / OUT 289.42 - _ - _ _ _ 4" MH53 ED 11 _---__ __-- \ I _� _ - _ z - �� ___ ___ - _ j S1 N LIZED % 1 _-- �___�---__ `�� _= _ _%T \ \_-------I�] LTI Z E D ss -53 m I T RS C; 10 _ -------------� ®-'sr 10+00 \ / AKE Ll /ca wv C. 8.#47 294. \ \ \ \ A ` \\ � \\� \\ \ � l \ \ - - - - / � \ n • / �: a ,.�-' i _ _=- 1 � RCP ®\o% \ \ \ s \ \ \ \ \ \ \ \ \ \ \ \ 26 RCP 1 N RCP�O.S% � � \ \ \ ✓ 42 \ \ \\ wl-I \ \ \ \ \ \\ Q � INV OU 2940 \\ \\ \ 1 \\ \ `- - - / / // l l C. 143 0l 8 LF 18'\\� \ \ \ \ \ \ \ `P\�\\ I D \ \ \ \ \ -28.00 GP \ \ \ I \ 17\ ® 2.0%\ \ \ \ \ \ \ \ \ \ I\ I _ \., \ \ \ l \ \ \ O 1 LF 4 \ + / \ � � \ TOP=285.58 ` F/24." CP ®0.50 \ - ��NVOUT=282.2\ �Jill \ It / / o � // / I I '�'/ i, \\\ 114L� _ __ __ -_a \ 1 /NVlN=282.12 \ / / / / -_ 1 C.9. 2 I INV IN=28212 / 208 LF18"\\'--295------`-_ '/NVOUT=282.02 /� / / RCP ®6.819 -� `� \ _ -- / X15 \ 90 LF 36" 8. 800 ------------- \ = /N=2827 VV 79 = 79 1\ l I �, - \ ` \ \ .66 W , 1 /ICP ®0.5% / oP 288.00 Flo, - c 1 /I 1 I f/ / N=283.4 1 \ / / �/ �► DI _ - - - - _ - \ _ _ - - - _ TOP=29Q C.B. ,¢'14 / oo \ - l /N=.A5 I TOP=290.15 288. ` \ V /N=81./34 /NV OUT=281.8 / 1 1 1 / tri / I \ \, \ ♦ \ \ \ \ \ 0.5% ��---__ \\ =284. \\ IN 2g5' C. B. ,/31 1 \\\ \\\\\ / I / I I I // / // 1 \ \ \\\\\ \ \ I / I I TOP=291.26 _ ____ \\ \� \--\ / \ 26 LF 18" / \ \ \ \ INV,1N=285.24 - -1 - I / \ / / / / / / 1 \ \ O S \ \ \ / RCP ®2. o% / I l \ \ \ I \ lly-V 1N=285.24 c.6. 3s _ \ / 1 \ \ / I \ l I / / \ 2 I S NV OUT=285.14 TOP=29150 \ \ \ \ \ _ 1 \ I C. 8. IJ2 ` C. B. f38 INV. -OUT= TB - _ \ I l / DI TOP=289.,5e- TOP=289. \ \ \ -L- 1 0q,� INV 1N=285.55 INV /N�5.91 103 LF \ \ \ \ \ \ --� / 1 \ \c 239/LF .515" 1 \ I I / / / \ 1 / C. B. #30 / +I 44 LF 1W' -1N=285.55 INV p T=2285.81 18'" RCP 1 \ \ \ \ \ RCP\ ® 0.579\ \\ TOP=291.29 24"�REF�INV OUT=285.46 / ®1.16% 1 \ \ \ \ \ I \ I I 1 I I \ I / ` / \ \ \\`�� \ TGS \ ♦ \ \ \ \ lNvlN=284.80 1 - t - ®p.s% �qO l INV58 LF 30" 0.5% 27 LF :,, / I I I \ / / I ® 0.5% i \ \\ l C. B. #2s ".; 1 0-\ I11�H .. � - / \ �` // / E \\ � \ l TOP=290.15 / �B. #33 \RCP ®06%� / \ ,\� 1 I I I / y / / FUTUR \ \ \ \ \ \ \ \ \ /NV 1N=284.41 P^ ITOP= 9.59 / 1 \\ /NV OUT=284.31 \ o, /� INV u =�e .69 / / - \ / ♦\ o\ // // / I \ I\ \ \ R VELOPMENT \ \ \ \\ I \ \ �� _ _ \ \ / 1 \ \ \ \ \ DE ®26 LF /2.09'• Lor ,{�, \ \ �\ 1\- \\\ 'y � \\ 1 t � `,. r/ (\\ \\\ '� ; \\ _ _ io 29�s.33 // I \\ \\ \\ \ QAC• e\ \\\ \\\ \\\�\�A,='\ \\ /) 1J6 LF 36" \ 1 \ - \ \ 1 + 285 - _ _ / / \ INV OU 39 / I \ \ �. to \ \ \ \ \ \ \ 1 \ \ RCI'P ® 0,59,% \ \ \ I i \ \ / d -------___17L, TO 8 E \ TOP=26W33 1 \ \\%\ \ \ \ \ .00 .8t X 18' RCP \ k /NV 1N=279.87/ \ \ �\ I ♦ \ \ \ / I \ \ '- - ® 5 o% \ m /N /NV OUT=2 ,9, 77 \\\\\�\ \ 1 26 LF \ $ 107 LF2369, B. X36 r18"RCP \ RCP ®2.0% It \\ \ Nom\ \ \ NY IN=7.00 \ \ \ \ I�y �/�/ g� > _ _ INVZJl1T 28 85 RCP ®20% l =284.00 /l \ 1 \ I \ , �, • INV OUT=278.47 \ T �` v X138 LF 24'" _ \ i \ \I 1 I ♦ \ \ TOP., 288.44 / 1 1 1 \ - \ \ ti �` RCP ®1. o% - _ i _ ZF C. B. ¢�6 \ \ \ \ \ INV '1�UT=284.417 / \ \ \ \ \ \ \ '' \ \ 24" RCP 2S / \ \ o\ \ \ \ \\ 1 31 LF 18" RCP ®4.0% / l \ \ - _ • ' \ � TOP=284.80 GJ \ \ \ \\ 11 \\ �\ \ a .:\. \ \ \ ® 5.0% INV /N=27B�3.2 / \ \ a \ / \ - \ 1 \ \ -B. IJ4 /NILO1dT-278.21 i \ \ \ \ \ \ C.B. /fF2 / \ \ \ 29-L� ♦ \ \ T?3P=296.1-8 \ ' C.B. \ \ TOP 288.66 / l / \ l \ \ a� - \ _ - 1 \ \ \ \ \ INV /N=280.56 18" RCP \ \ \ \\ � \ ♦ \ l /NV IN `283.16J111@-'" \ \ \ \ i \ - - _ 4Y -V /N=280.56 ® 2.0% \ \ \ \ \ /NV 1N=283.16 / / i \ \ \ \ , \ 1 \ \ RCP ®�Y (f7% - \ \ INV-06�T=28Q 46 \ _ _ _ � � / INYTOP=284.58 \ \ \ �� \ /NV OUI 283.06 n/ / / \ \ L \ \ • \ \ \ \ \ \ \ _ o INV 1N=2277.63 ks \ \ \ INV OUT=277.53 \ 1 \ I 1 l \ \ \ \, \ \♦ aXy 1 \ \ \ "'_-" CB.�C35 \\ 71'GP ®2.0% / ®- \\ � • \ \ \ \ ♦ \ f 1 / \ \ \ \ \ roP-2Bs3 \ \ _ 11 LF3�' - c.6.,.44 _ \ /----\ /lOWIN=2 -C.B.40 \/Nv�(�T�2 25% / / TOP=282.28 , , - - - - - - / 1 TOP=•287.83 \ _ _ \ \ \ INV 1N=276.41 _..� - \ \ \ / \ 1' 1 \ \ \\ \ I \ I 2051 LF 36" \ / \ \ \ \ _ INV OUT=2613.23-- \ \ P0 0' / \ \ \ \ 1 I RCPI 9 1.07% \ / \ \ \ \ \ ` T `CONFLICT BOX ?A \ k /NV 1N=276 41 \ \ 1 \ y 1 \\ \ \ 1 ♦ \ \ I - DFTAtE \ :._ 15 _WV_0U-T=276.31 \--(SEEs--\---- \� `---- ---- �\ \ \ / 26 LF,�6 \ \ \ ♦ \ I \ \ INV. 270.95 TOP 27-Z z8 \ \ \ \ \ /' / j - l7CP ® 2.0% 48" /NV. IN - 21 \ ♦ ` \ \ / _ \ \ l �uiaL euRr \ / cB _ 3 \ \--IWv_IN=2 5.79- _ 24" /NV. IN 270.79 � / \ TOP -282.28 \ \ \ \ \ \ \ 4 /NV. OUT 76 / /' w / \ _ T4 N \ \ \ \ \ \ \ \ \ \ \ �G'' 'Z „ /\ / INV OUT=275.66 \ \ / \ \ \ _ - / (1i \\ \\ \\ \ \�\\ \ \ \ ♦ \�� \\ \ _a ��'�� \\ \\ \\ \\ \\ \\\ \/36 LF / // c.e. ,/2\\280- t 280\\ \ \\ l \\\ \ \ ♦ x, \ \ \ \ \ 2 /RCPT P�. // -TOP=279.00 \ \ \ \ \ \ \ moo\ \ \ 11 \\ \� 5%x0 e /`. INV /{ 272.84 (C.B#3) 6 �. \ \ \ EXISTING IN\TLANDS \, \ \ w INV /N=266. (EB�j�IS) SMEAM TO iZEMAIN \ / \ OUT=266.87 i \ \ 78/ D.1. 20 \ \ \ \ /NV=OU 282.15 \ \ \ \ (D� NOT D/S RB) \ \ \ \ \ � \ \ \ ♦ \ \ \\ \ \ TOP=276.5(' _ \ \ \ _ ♦ 26 LF I#" RCP ® 4.9% \ \ IN OUT=269?34� \ \ \ \ \ RCP ®1.0% - - - - \ \ _ _ \ \ I \ \ / / \� \ \ I C. /25 # \ �'�E� -J- =S; 1 \ \ \ 2� \C B.- 19 16 LF 2 \ \ - �1� - _ INV %L 26 . TOP -277.68 \ \ \ - - \ 1 1 1 1 \ \ TOP -286.,37- _ \ \ O. RCP ®0.5?'y \ \ \ \ \ \ 7 INVlN=280.87 \___- \\ \ \ INVlN=269.86 / \ 1 1 1 1 \ \ INV /N=280.87 _ \ \ INV OUT -269.761 \ 1 1 \ \ \ .� \ ♦ \` \INV OUT=280.77 \ \ 26 LF 3 \ 1 \ \ \ \ j \ ♦ sem \__- \\ \ \ 1 RCP ®1 5( x0 -8 b71\N� 75- �, _ \ _ -285---_ \ \ 1 \ h \-` 2 1 \ \ \ \ o\ - \ \ \ �`� ion=27 s� \ \ \ - \ _ / /\ 1 320 LF 36" \ \ \ // � \\ \\ \_ \ � '�. ��\\ \ ` \ \\\ \ ----�// \ 11� \ \ \ \ \ ♦ RCP ® 0.76% \ \ \ \ \ \ / / / INVouts %F \ \ \ \ \ - _ _ , / /NV 1N�26 . 0 19 \ / \ \ \ ♦ \ \ \ \ \ \ \ f \ \\ \ \ ^\ Ro _-_ \-- \\ \\\ RAS OT�\U/TPRT/oj� \\ �/ lN�4PTH �% S /= vw _f / \ / 1 \ _ / _ _ -O\ \\ ♦ pO\ .. \\ I 1 // /./' // \\\ \\ \ \\ \\ \\ �s \\ \ \\ \\ \\ \\ \ \ �� >c\\ �\ -\\ \ `\\ \\��0�\\\\\ �,\\\-- /// /,/ / --- _/ \ \,// \ \ \ \ \ \ \ \ \ \ \ \ \ \ \\ \ \ ♦122I / / /- \ V A c / BRICK BOX 260 LF 42"J - v 1 TOP 285.55 I / / RCP ® 1.86% \ \ \ \ \ \ \ \ \ \ \ \ / \ \ \ \ \ CONFLICT BOX #2A \ \ INV OUT 277.14: \ \ \ \ I \ I \ \\ \�\ \\-_ \_ TOP 93.50 \ \, `;,;\ 15/k0 / \ \ \ \ \ \ \ \ \ \ ` _ \ \ \ / / / - - - 24" RCP 24" RCP \ \ \ / \ / - � -- - ✓ - \ \ \\ _ _ i _ \\ \\ IN /N /12 -257.00 26 LF 18" l \ \ \ \ \ \ \ \ h \ \ \ \ \ \ _ \ \ \ \ \ CLAs.�B < '7- INV. IN 270.79 INV. OUT 270.76 \ \ \ \\ \ / \ \ \ \ \ \\ \ \\ \ \ 2 ! \ \ \\ _ -RAS EMFROEN6Y / � / / / / 1 / � /N/(6 )=262-061 \� RCP ® 2.0% / \ \ \ \\ / OU t- - - / / / I / �'� / O� u \ \ \ \ \ \ \\ \ \ \ \ \ \ \ \\ \ \ \ Ql�.\ \ \ \ \ SPILL -WA -K 00 / ♦ l V T-25 73 _ _ _ % / v BRICK BOX ��' c'o`v / C.B. ,¢�21 / - �' / / k / / / - % - % - i \ - 1 -/ \\ k / . \ �\ \ \ \ \\ \ \ / /� _ / \ / \\ ♦ $\ / / TOP 285.55 / l \ I I \ \ \ \ \ \ \ \ \ \ \ \ \ \ \� v� `L L \\ \ \` _ / / _ _ " \ / / ♦ (P/0 /NV /N 276.62 F AV. \ I \ > \ \ \ \ \ \ \\ \ \ \ \ \� \ - _ \ \ \ �\ // �� - _ / / �s / / / ®- - /(1� LF 46" \ \ 5 • k0 / INV /N 276.62 ' l / I I I /\ \ \ �"� \ \\ \\\ \ \\ \ \ / �-. - \ \ \� �\ / / / �J goo _ /\ R ® 1.0%/ / INV OUT 276.52 / �L�i� / I I I * \ O� \ \ \ \ y \ \ \ \ 0 �`� \ \ // \ `✓ / / / �L r _ FES 48"RCP I I ' 11 \ \ \ RCP �i 1.09 / // l \ \ \\ \ \ \ \ \j/ \\\ _ l // / f ` / - - / _ �\ \\/ ./ . \ X58 LF 36" / / I \ \ \ \ \\ \ \\ _ / / h� / / - It 24" RCP I ' 24" RCP \ \ \ ♦ I / / / / / I I I \ \ \ \ \ \ \ \ \\� 'cam; /- \ \ \ \ J /%///il\llh/� i - / / / INV. IN INV. IN 270.79 1 ' INV. OUT 270.76 1 ♦ I / / I \ \ \ / \ \ \ / 267.21 9" \ \ / / / / \ \ \ \ \ \ "1 \ \ - _ / / / \ / / / ! % ✓ CB # _- P.B #23 / l I I \ I \ \\ \ \ \ \ \\ \0'I%� /TOP TOP 285.75- \ 1 \ \ \ \\ \ \\L \\\ / /NV lNBt. 8.33 I \\ k \ ♦ I/NV IN 2730 FILL BOTTOM /NV OUT 78.23 I \1 r' \ ♦I/NV OUT 77.20 1 1 _ \ \ \ \ \ \ \ 48" RCP i ♦ I / \ \ \ \ x 24" RCP x INV. IN / W/CONCRETE \2 \ o \ I \ \ \ \ \ \ \ \ \\ \ \ \ \ \ m m 267.21 I 31 LF 90 F 18" \ \ \ \ \ \ \� -_N11�_\ M-iplcYil �J \ ®RCP 1 \ \ 1 \ / y \ \\ \\\ 48" RCP �/ \ I \ ♦ / \ / \ ` \ \ \ \ \ \ \ \ \ \\ \ \ \\ \ \ \ \ \ \ - \ FES., 7 / \ INV. IN I m I I m I \ \ \ \ \ ♦ \ \ \ \ -_ \\ \ \ \ \ \\ \ \ \ \\ \ \ \90- x - \ \ \ \ \ \, \- - - - f \ \ \ \ \ \ \ \ \ \\ \ \ \ \ � \ � � _ ANTI�'EE %` NV /N--255.0 i \ ( I \ \ \ \ \ \ \ f� 267.21 I I I I \\ \\ 1 \ ,-__ \ \ \ \ \ \ \ \ \ \ \ �' \ 5 26 LF ' RCP ®1 B0% \ TO 84.46 \\ \\ _-__ \ \ \ \\ \ \ \ \\ \ \\\ \ \\\_� 2 78. JO NO JOINT PERMITTED C.B. 5 \ . - _ \ \ \ \ \ \ \ \ \ \ WITHIN STRUCTURE CONFLICT BOX DETAIL TOP 284.46 \ \ _ . ♦ INV OU7`.278.20 \ \ \ \ / \ _ _ _ ® \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \\� \\\ \ \ \ \ \ A \ \ � I - \ - \ IN OUT 278.56 \ \ \ \ \ \ \ \ / \ _ \ \ \ \ \ \ 2 \ \ \ \ \ \ \ \ \ \ \ I r \ CLsjaS�li'/�RAP \ \ % \ \ \ \- - \ \ \ \ \ I I \ \ - 4r OU E PROTECTION NOT TO SCALE \ 280 ---- \\ \ \ \ 0 \\ \ \ \ 1 I \ \ Z O / \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ BEGING WfE2T/#-1� ' / / / / / \ \ \ \ \ \ \ \ l \ \ \ \ \\ \\ \\ \ \\\ \ \\I/ \ \LEA4ZTH J5 - NI NBIIC%G WIOTA 39' SCALE: 1 - 60 i \ \\\ \\ ♦ �\ \ - .. \ \\ \\ \\ \�\ \\ \ \ \ \ \ \ \ \ 6' �\ \ \ \, V r 5� \ \ \ \ \ \ \ \ \ \ \ c \ \� / / NI \�\ \� \ ` \` \\ \ \\ \\ \\\ \\ \\ \\ \ \ \ \ \ \ \ \ \ \ \ \ \ \\\ \ \N 0 60 It 120 150 180 210 240 \ \ � AND THE ANGEL SAID TO THEM, "FEAR NOT: FOR BEHOLD, I BRING YOU GOOD TIDINGS OF GREAT JOY, WHICH SHALL BE TO ALL PEOPLE. FOR UNTO YOU IS BORN THIS DAY IN THE CITY OF DAVID A SAVIOR, WHO IS CHRIST THE LORD. LUKE 2: 10-11 O m CO XI O rn m `n N m LO CV w z O w V � w w z Zz w cn Y U 0 W � 3: WU U)zZ (O O Lc) 0 00 r Z (N =N �z z Z �w () J W w> 0000 z BLN=C-1874 ,111 ,I CARO p"'I" Q SEAL < 19843 .FNGINE�E� 0) % /ChAEL / 2/1 /19 SRA/NAGE PLAN REVISIONS FILE NO. 2018-033 HORZ. SCALE: 1'=60' VERT. SCALE: NONE CE -04 PROFILE LEGEND — — 30' OFFSET LEFT - — — — - 15' OFFSET LEFT -- -- EXISTING C/L - — — - 15' OFFSET RIGHT — 30' OFFSET RIGHT 315 310 305 300 295 290 - 285 280 275 270 S, go 6 P NFRS PA/9i(��Y.4Y PVI STA: 11+00.00 PVI ELEV: 304,17 K: 2 0.3 3 LVC; 100.00 PVI STA: 12+75.00 PVI ELEV: 291,92 K: 17.45 LVC; 100.00 P \�1 \ 0 c1 �0 06 ti�hh hkG 10 V ''0QoI p. p. -�° y (b0 JG yQ W F 0 I�Q \� \�\J111.ti0�,45 RQr Q �� `' Dp GQ 6 �p6 0 1 r Ci tih h t. 00p� / �hh��" I so' ee G,��pJ 6 h0 — — til � 1 b 1' ' p ° ! m' �� p�° �QQ, �r 1 g �� �� h h hp tip p� tih `L ir` tih tih h BOJ . 4 l h p D-D �0 Jrrti \'o' ro Qrr`` hrr`L� `Sd�\ F ��� �' �`LOJ� Q O GO �C�\��pJ�rr rc�� F �p� G �OQ I I �.. F ®� /� �'`' Q J� `L N .J. A. n �� ,G'�0 \ �� �� Nh n - _ _ c)-.4 ./r �, ��� .J / C) _ _G. _ ,co,� o \, <<b a4 Z n\ N n G',� _� 0 •- v \ \ 900 PVC WATESR 3' BNND R12 S W ---- -- -- i --- --- -- `��- -- \ - — -- ---- —& V ------ 2 ' C 10' RAIN. T ` EASM'T - 3 m 30" STD. C&G p 00 STA TASIA STA_ STA STA_ vi / TA / 1 — — — — — — — — — ----- - 18+00 ------ ---- 17+00 - I -- 18+00-- --------X19+00 -- ---- 20 00 - ------ 8 �00-------- —+---- �h — 30" STD. C&G \ / —------ — c�Qrr------------------ ti�roJ�r G�� \ h�hp11°Q0 L \ --��\ �� -- -- -- -- -- \ — 1-- Q —`r —........ -- VA --------- — -- �y�-------------- =�,— ------ — — — — G0� °—_----��`L�t �� \� -----_ --- _;mLam -- -290— \\ t�� ------ 1-1 _--� /ice-----'� \ — �--•� \\ `---------------- \_ -- SCALE: 1 " = 50' 0 50 100 125 150 LOW PT STA: 17+50.37 LOW PT ELEV: 286,21 PVI STA: 17+50.00 PVI ELEV: 285,89 K: 39.71 LVC; 100.00 HIGH PT STA: 19+38.46 HIGH PT ELEV: 288,01 PVI STA: 19+50.00 PVI ELEV: 288,39 K: 3 0.7 7 LVC; 100.00 LOW PT STA: 21+82,14 LOW PT ELEV: 284,32 PVI STA: 21+75.00 PVI ELEV: 283,89 K: 2 8.5 7 LVC; 100.00 PVI STA; 23+50.00 PVI ELEV: 286,52 K: 50.00 LVC; 100.00 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00 20+50 21+00 AND THE ANGEL SAID TO THEM, "FEAR NOT: FOR BEHOLD, I BRING YOU GOOD TIDINGS OF GREAT JOY, WHICH SHALL BE TO ALL PEOPLE. I FOR UNTO YOU IS BORN THIS DAY IN THE CITY OF DAVID A SAVIOR, WHO IS CHRIST THE LORD. LUKE 2: 10-11 - 315 310 - 305 - 300 - 295 - 290 285 • 00 c0 Orn �;-o xl O m `o o^ . N 0_ Lo N Ao Ld w w z Zz w Y U O H W �� WU Z z (0 o00 �00 z N U N= To Z z Vw (n J W w> 0000 z BLN=C-1874 x , CA �. o' -ss/ / SEAL 19843 '01AEL S..��� 280 SOUTH FLOWERS PARKWAY - 275 - 270 REVISIONS FILE NO. 2018-033 HORZ. SCALE: C:) N VERT. SCALE: 1'=5' o In o N o c o M o N o� o m o co o In o� o cu cu OD o l!7 n 0 0 0 n U-) L6 N (U (LJ oo l!7 00 00 U7 4p 4 m oo t0 0o t0 00 � oo N 0� o 0� cp 00 00 00 00 00 OD OD OD 0 0 o N M 2+ Ocy) r, 00 0� o cu cu(U CLI Mku cu cu ca 04 U W W W 0- W U W W W W ~ (� w H w U W H w Q (� W W (� W W �H i J 0 w 0 �' w O �' (/� (/� H a_ W a_ W a_ W 0 W N \\ Z - >- \ \ o \\ M D m II --J— — + Q W O WQ Ln \\ W k v Zp, IN Z8 \� � N W � U CN Ea r- loo n n — -- — Ztkz 45° — v v N BEND I I I I 45°�-,2 m -�� BEND I _ i +I--r�— — 77 _— I III RCP II 74, ii Ir 1 __ ` -- TE m --- J I h - - -- , ----- „ 36„ R ------- --------- — I1-- — I I 1 ------ B45* END II �— -�, -Q E m MIN. _ ---_- ----- _____--- ------- 1 1 II4124' I�-- BE - -____ --_---- 36" RCPCL, I----- u 45°° SS -_------ ---- ----- - --- -- 1 N.74ti 1136,, I `cp L --- ___- -BENDND 1 -n LL--- Of p j o F J ��0�4i m h� z Ln m M ° O 00 0i w w Ld 45 tea.. J W BEND z :2 W 0104> w xc�H m p° mJ p U) >ej W� O w xm� Z z N i 2 I dOLn O U ti Q 00 0x0 U W trjLn r� N N Ln O O rn 00 N ro N a0 O I� r7 O O O c0 N M N N u7 I� O O 07 O- N 07 O 0_ W O O ao 00 O N ao r- ao r7 N OO 00 Ki 0O 0)I O 00 �� a0� 00� ao� �� Oc0 O� Oc0 O� 00� r- �� �� x O(fl �i� _j J 00Ln �� M� ��� Lo 'i Lo 'i Oc0 X00 00 Op 0) 0 O 0)6 O m� m'i O cy) m �� �O O M m� m 00 co 00 000 00 a0� 00 00 co 00 a0� 00 00,6 00 a0 N co a0� N 00 00� 00 00 N 00 �� 00 ao� 00 - (0i� 00 Z z O W N 00 N 00 004 00 LoO 00 LoIi 00 00,6 00 coN oO 00 0) XO r� �� N �� N �� N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N NN U N N NN NN NN NN NN NN W Of o_ 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00 20+50 21+00 AND THE ANGEL SAID TO THEM, "FEAR NOT: FOR BEHOLD, I BRING YOU GOOD TIDINGS OF GREAT JOY, WHICH SHALL BE TO ALL PEOPLE. I FOR UNTO YOU IS BORN THIS DAY IN THE CITY OF DAVID A SAVIOR, WHO IS CHRIST THE LORD. LUKE 2: 10-11 - 315 310 - 305 - 300 - 295 - 290 285 • 00 c0 Orn �;-o xl O m `o o^ . N 0_ Lo N Ao Ld w w z Zz w Y U O H W �� WU Z z (0 o00 �00 z N U N= To Z z Vw (n J W w> 0000 z BLN=C-1874 x , CA �. o' -ss/ / SEAL 19843 '01AEL S..��� 280 SOUTH FLOWERS PARKWAY - 275 - 270 REVISIONS FILE NO. 2018-033 HORZ. SCALE: 1"=50' VERT. SCALE: 1'=5' 21+50 22+00 22+50 23+00 23+50 24+00 24+50 25+00 CE -05 305 300 295 290 285 - 280 - 275 270 155 G 1 Q'�x \moo p\� -GQ- _ _w. - ,. � `\ R '� M. H. #7 G 0 \ \\ \ \ \ \� `♦ \0� 1k 5��' TOP ±290.69 �� \Ys� \ 0�. QOM 1� 1� �1�� ..,. 6" LOT#1 /NV.V. 279.85 6" LOT#2 /N 280.85 �� 9 � �0 INV. OUT/279.35 I B. /30 ��\� G \ o o \ ♦ \ ���J 0 �F @ 05 �6 /INV �1N=284.80 C30 GQ ,� 90 /�&1 / IN OUT=2870 .' C.O. TOP/±292.50 \ \ ♦ \ \ G �J 0 F ���a�" \ I INV 281/.10 \ \ / '� \s•> \� 6 58 LF/30'" TRGQ \ �p \ \ RCP F 0.59' o`\ \ ARE \ (�LF 6" /SDR 35 \ �P S.S.1@ 2.089 91.9 • �g �g \ ♦ 1\ R q\ \ \ 0 Q G� OF 1 \ lC.B. / ,`� �`� 90.15 Q J 0�� /NV 7L-284. J1 15.5'R ♦ \ \ �J' F \ �� 1�0�° I w \ \ \ \ 6 @ \ -KEEP RIGHT' �w-. I' � �1 \ �\ S/GNN / �OO�g. G OQ o ' 1 9d1 �, \\ F \ ♦ 5 9 30'' \ JI 8• �`� i� fig• ,�� (i 00 P Dz�dj i \\ Y, \ \ � \ \�r1 �(0 GQ �• G COQ , G.( 8 , i� xx 1� •�� . \ `\R ��J 0 1 \ `1sT N / J / PROFILE LEGEND - - 30' OFFSET LEFT - - - - - 15' OFFSET LEFT -- -EXISTING C/L - - - - 15' OFFSET RIGHT - 30' OFFSET RIGHT SOUTHMERCH.4N7 AVENUE / Fav -1c.6 P9 SCALE: 1 " = 50' 0 50 100 125 150 9+50 10+00 10+50 END LOWER WA TERLINE SECTION TO AVOID CONFLICT D +I I , I 305 305 300 300 295 305 290 300 285 295 280 290 275 285 270 280 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 AND THE ANGEL SAID TO THEM, "FEAR NOT: FOR BEHOLD, I BRING YOU GOOD TIDINGS OF GREAT JOY, WHICH SHALL BE TO ALL PEOPLE. FOR UNTO YOU IS BORN THIS DAY IN THE CITY OF DAVID A SAVIOR, WHO IS CHRIST THE LORD. LUKE 2: 10-11 80 LF 6" SDR 35 PVC SS @ 2.089 TOP=289.86 / INV 1N=285.55 C. 8. /31 /NV 1N=285.55 TOP=291.26 /NV OUT=285.46 INV 1N=285.24 INV IN=285.24 C. B. /38 INV OUT=285.14 TOP=289.81 C.O. TOP INV IN=285.91 (292.00 LC INV OUT=285.81 103 LF 290.09 18" RCP �INV. 282.51 2" WATER ©1 169 44 LF SERVICE 24" RCP 24" WIDE C. B. /39 00.57. iS'TOP BAR / TOP=290.50 STOP / (THERMO) / / INV OUT=287.10 SIGN � / 24" STD. C&G 24" STD. C&G / TRANSITION FROM HEADER CURB to 30" C&G 000 � ` i�0i`• Oco.. � LOW PT STA: 10+99,40 LOW PT ELEV: 289,61 PVI STA: 10+80.55 PVI ELEV: 289,28 K: 33.10 LVC: 100.00 PROFILE LEGEND - - 30' OFFSET LEFT - - - - - 15' OFFSET LEFT -- -EXISTING C/L - - - - 15' OFFSET RIGHT - 30OFFSET RIGHT HORZ. SCALE: 1"=50' O 1 U 0 z_ Ld W W z_ U Z z w Y U O H WLd cn WU z00 0 L • �00 z (N = U To 00 z �w J W> () w z 0000 CD v In N In 10 0 0 M o pi 00 CD M + N cn C)_ U W H W 0- W a W a _j �0� 0 ON N q% � J McliO W zzk 00 n z bill -� U m U � m U m j_8- 11 18"_I L-- __ 18" RCP- Lu-� 0) g" C-900 Ll u PVC WATER U w 00 -x Y (714 J - C v x � N N0M0 O Cn NO) r. r-00 c0O Qr W O� \\ m 00 NN �O 0)O) m N W = O V 0000 N 00� N N ---, \-, X O N 11\ W 0_ o w o o -------- ----I - - - VC �Qf -h } � I - --------- ----- ER -- _ ---- m I II I1 �\ � 001I 36"45° RCP BEND 1I 1 U izmn X v z oaz -- - - - - -- - - - - - -4t--. LJ - --- - m { I N X h m m N---------------- -- I I 36" I I ------ N O Qw N N Q z O z O - < 0 0 0 24" Id Ld = MIN. CL. m U U L, af 45° w 0 0 o N BEND (2) -3:- Q 0 0 ~ z 0O 0 w OW w Z U U U J H D J J 00 x _j i-- L,U -i00 0 .0-! O O 00 4 6) O �p N O 0p u7 � O � N N N O N c0 N N 00 L0 � O I� � N c0 � .� c0 O � 00 � 0 00 O O N O � � N N N 0 N O M N CT) � r7 O) N a) - � 0 0 O) M O) N 00 p)I� N00 p)(D N00 00 a0 CO Ln 00 00 M 00 M X O NN NN NO N NO N NO N NO N NIN N 0400 N NI N N N 0400 N NIN NIN N N NIN N W 0' 0- 9+50 10+00 10+50 END LOWER WA TERLINE SECTION TO AVOID CONFLICT D +I I , I 305 305 300 300 295 305 290 300 285 295 280 290 275 285 270 280 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 AND THE ANGEL SAID TO THEM, "FEAR NOT: FOR BEHOLD, I BRING YOU GOOD TIDINGS OF GREAT JOY, WHICH SHALL BE TO ALL PEOPLE. FOR UNTO YOU IS BORN THIS DAY IN THE CITY OF DAVID A SAVIOR, WHO IS CHRIST THE LORD. LUKE 2: 10-11 80 LF 6" SDR 35 PVC SS @ 2.089 TOP=289.86 / INV 1N=285.55 C. 8. /31 /NV 1N=285.55 TOP=291.26 /NV OUT=285.46 INV 1N=285.24 INV IN=285.24 C. B. /38 INV OUT=285.14 TOP=289.81 C.O. TOP INV IN=285.91 (292.00 LC INV OUT=285.81 103 LF 290.09 18" RCP �INV. 282.51 2" WATER ©1 169 44 LF SERVICE 24" RCP 24" WIDE C. B. /39 00.57. iS'TOP BAR / TOP=290.50 STOP / (THERMO) / / INV OUT=287.10 SIGN � / 24" STD. C&G 24" STD. C&G / TRANSITION FROM HEADER CURB to 30" C&G 000 � ` i�0i`• Oco.. � LOW PT STA: 10+99,40 LOW PT ELEV: 289,61 PVI STA: 10+80.55 PVI ELEV: 289,28 K: 33.10 LVC: 100.00 PROFILE LEGEND - - 30' OFFSET LEFT - - - - - 15' OFFSET LEFT -- -EXISTING C/L - - - - 15' OFFSET RIGHT - 30OFFSET RIGHT 8+50 9+00 9+50 10+00 10+50 11+00 11+50 12+00 305 300 305 300 295 00 co Orn �;_0 xl O m `n o^ . N 0 Ln N W z O 0_ HORZ. SCALE: 1"=50' O 1 U 0 z_ Ld W W z_ U Z z w Y U O H WLd U) WU z00 0 L • �00 z (N = U To z z �w J W> () w z 0000 In N In 10 0 0 M o pi 00 C)_ U W H W 0- W a W a �0� 0 ON N � J McliO W zzk 00 n z bill -� U m U � m U m j_8- 11 18"_I L-- __ 18" RCP- -- g" C-900 Ll u PVC WATER U w 00 -x Y (714 J - x OD x � N O Cn NO) (714 (c) r-00 c0O O� N:� m 00 NN �O 0)O) N N N 0000 N N 0000 N 00� N N X O N W 0_ 0- 8+50 9+00 9+50 10+00 10+50 11+00 11+50 12+00 305 300 305 300 295 00 co Orn �;_0 xl O m `n o^ . N 0 Ln N W z O 0_ BLN=C-1874 �. o'EssR04 . SEAL 19843 FNGINE�� EL 2/11/19 290 SOUTH MERCHANT AVENUE PUBL/X WAY 285 280 REVISIONS -11 FILE NO. 2018-033 HORZ. SCALE: 1"=50' O 1 U 0 z_ Ld W W z_ U Z z w Y U O H WLd U) WU z00 0 L • �00 z (N = U To z z �w J W> () w z 0000 BLN=C-1874 �. o'EssR04 . SEAL 19843 FNGINE�� EL 2/11/19 290 SOUTH MERCHANT AVENUE PUBL/X WAY 285 280 REVISIONS -11 FILE NO. 2018-033 HORZ. SCALE: 1"=50' VERT. SCALE: 1'=5' CE -06 295 290 285 280 275 270 - 265 260 / \ / f \\ \ \ 8 LF 18" / CN \RCP 9 2.0% D. =284.00 \ N INV OUT=278.479' \ 29 LFo \ h C. B. 16 / N TOP=284.80' 56 LF 36' \ 92.07. \ INV /N:7-72:18. 31 RCP 9 2.07. \ _ _ 4NL0UT=278.21 STOP \ SIGN CB #5/, - TOP=284.58 114 LF 36"' - - - � < O y INV 1N=277.63 w RCP 9 2.5% _ \ \\ FIRE /NV 1N=277.63 - - - M.H. #3 �� - i HYD. INV OUT=277.5) / 5' DIA.v20.5 R INSIDE DROP 4C. 3. #4 TOP ±278.35 ?�, \�� TOP=282 28 INV. IN 269.03 (#4) INV. IN 264.22 (#5) ` INV. OUT 264.02 46 LF 8" CL DIP S.S. 9 2.07. INV. 270.95 MIN. 9"BURY � , 36 LF 24" P CONFLICT BOX 2A 9 'tf 61% (SEE DETAIL) - _\ TOP 277.78 \ 48" INV. IN 267.21 \ 24 "INV IN 270.79 D. 1. 120 24" INV. OUT 270.7 TOP=276.50 INV OUT=27270 ��0 TOP 277.68 RCP 916 LF 20. \ INV 1N=272 62 \ \ INV OUT=272.52 / \ 26 LF 30" \ \ \ I RCP °® 3.2%>` 0� 40STOP� S GN 1' CD INV IIV=276.41 X50 p - \ INV' V=276.41 - lNV OUT=276.31 �i 26 LF 36"'° _o\ / C. B. #3 RCP 9 2.0%\ a _ \- - - -" TpP.-282.8- - - • INV 1N=275.79 _INV OUT=275.69 \ c:a. #2 - - - 280 - -\ x l _70P=279. 00 N T - //VV 1N=272-84_( 8L3) INV 1N=266.97 (C.B.#1_�9) - - - �� 2UT-2_66.87 88 LF 48 - - ����� \�� RCP 00.51w. / �/NV���t 7-3 x \ \ \ /' �' / ` \ h� H. \#5 \ \ \ \ \ \ \ z, P /IN, / / \ TOQ ±:77.61 \ \ \ ASF INV. \IN 1268.,E \ \ \ \ � C.B. 118 /NV. UT X6\.5'6 \ / R/ / \TOP=277.68 \ Q %�V / \ INV 1N=271.68 1 \ 1N=271.68 C.B. 22 xP G / 2 �/ / / \ \ \ \ INV\OUT=267.411 TOP 285.55 \ "Ing 0� \\ INV OUT 277.14 \/�Oj .0 Fo \ \ \ \ �\ \ FIfieri / /E����� "o. - �O, YD EPS/ /260 LF 42" \ \ \ Ff% RCP 9 11.86% \ \ tom •\ V \ C. B. #24 - - TCP 2(3k.05 INV IN X78.33 INV OUT 1278.23 1 00 . L RCP 1 \ \ PVI STA: 10+64.50 PVI ELEV: 285,35 K: 5 2.0 8 LVC; 100.00 �r u I \ \ 26/LF 18" R& 9 2. 0% l C. B.1 #21 TOP 285.55 INV IN 276.62 INV IN 276.62 INV OUT 276.52 �58 I 36" RCP 9 1.0% C. B. 123 ♦ \ TOP 285.75 ♦ \ INV IN 277.30 \ ` INV OUT 277.20 EASTME/�CH/INT/I4ENUE LOW PT STA: 13+20,38 LOW PT ELEV: 277,52 PVI STA; 13+00.00 SCALE: 1 " = 50' PVI ELEV: 275,93 K. 30,10 � 0 50 100 125 150 LVC; 200.00 0 PROFILE LEGEND - - 30' OFFSET LEFT - - - - - 15' OFFSET LEFT -- -- EXISTING C/L - - - - 15' OFFSET RIGHT - 30' OFFSET RIGHT 295 290 285 280 275 270 265 260 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 AND THE ANGEL SAID TO THEM, "FEAR NOT: FOR BEHOLD, I BRING YOU GOOD TIDINGS OF GREAT JOY, WHICH SHALL BE TO ALL PEOPLE. I FOR UNTO YOU IS BORN THIS DAY IN THE CITY OF DAVID A SAVIOR, WHO IS CHRIST THE LORD. LUKE 2: 10-11 om �00 xl O m o^ N N w z O w Q z W~ w w WU) Z z c0 O00 z N = U z Z Vw (n J Ww= 000 z 2 O U 0 z w w z 0 z w cn Y U O BLN=C-1874 Z 0 Q V � O y Qc O 2 ct �w cm �v �. o'6sR / SEAL 19843 s � '.FIVC INE��',�`�co) .`� �'CHAEL S�v�_�`°• '', i „qe i ee /2/1/19 EAST MERCHANT AVENUE REVISIONS -11 FILE NO. 2018-033 HORZ. SCALE: 1'=50' VERT. SCALE: 1'=5' CE -07 m 0 m o U-) o M w o r" r- N 00 0� u) 00� 0 l!7 0 m- CD 0 o U-), (n o CC m o T (U M C o (U 00 00 r- z r� o l!7 0 - cu 0 N 2+ N ku 2 + 00 V r N �p - �p N - > w (, w ~ w (, wQ a- _ -If� ~ w - w - w W W w 0 W (n In H (n C a- w w a_ w N �k N m U -.� � Q N 7t = II x -- II__ o II II Z r J _ N � ° ILL 00 v m / i z 45° BEND _ /, � -- 265% ---gut- 36" RCP I I U I I -�� I 36„ - __ , C -__ \ /� / II _, w - �' II II Cp 24" MIN. -- _ N _ a/j/// -- // ,-� II �� (3 45° m x Y _X o _____ o � BEND 45° w m o - _m _III__ I I -1 fn 1148"RCP N U T e0 00 Q U I I O i t I OLd I W Z Y o I I I J Ld o OI I - m www x x Ln Ll- O ---- - U N 00 OaZ af U 46 LFA" -5U 00 L` w J 35 S.SLd ® 0.6% 0 co O ..,. N co Ln c°" O " ON =O Z rn� zz ccoomZ Cp c0 O r� C�� � c0 r) r7 O m �00 - r- N N �� O � N 00 � N 00� O 0000 NN � 0000 � O) M r,r- c0 ZZ _ cri r- O) N 0000 00 00 't rri N� 00000 NN 0000 NN 00ai NN r- NN NN r- NN ZZ' NN r-0) NN NN 0000 NN 00� NN 0000 NN XO w Of - - w 295 290 285 280 275 270 265 260 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 AND THE ANGEL SAID TO THEM, "FEAR NOT: FOR BEHOLD, I BRING YOU GOOD TIDINGS OF GREAT JOY, WHICH SHALL BE TO ALL PEOPLE. I FOR UNTO YOU IS BORN THIS DAY IN THE CITY OF DAVID A SAVIOR, WHO IS CHRIST THE LORD. LUKE 2: 10-11 om �00 xl O m o^ N N w z O w Q z W~ w w WU) Z z c0 O00 z N = U z Z Vw (n J Ww= 000 z 2 O U 0 z w w z 0 z w cn Y U O BLN=C-1874 Z 0 Q V � O y Qc O 2 ct �w cm �v �. o'6sR / SEAL 19843 s � '.FIVC INE��',�`�co) .`� �'CHAEL S�v�_�`°• '', i „qe i ee /2/1/19 EAST MERCHANT AVENUE REVISIONS -11 FILE NO. 2018-033 HORZ. SCALE: 1'=50' VERT. SCALE: 1'=5' CE -07 300 - 295 - 290 - 285 - 275 - 270 - 've publij 1 2" WATER 1 / SERVICE — — — L1, /yF I IV " A W H4 (4rf)? C. B. #35 TOP=286.93 INV 1N=282.04 INV OUT=281.94 O It 1"=50' Orn 0 / 1 �k c� x1 �k N 00 = N 44 o^ N = N -- — 1 ERVICE W 0p Z N O. _ n U� O U C7 —285 _ < Z \ a �Ld w w 0. • '� zz z �\ 0'-U— Y NCDOT \ \ *�� EASEMENT — — O STANDARD H W N GAURDRAILI f` O zZ00 0 L Z N N= U To Z RETAINING WALL Vw J W (n w> (SEE DETAIL) + 00 Z \ M.I r\\ \ 1 W p7 ��LF C9 Sp + W C14� Qj f� M.H. #b\ \ - �►. � � �� � \\ � _ _ \ m- Ld N H FIRE _/ \� 212-�— c HYD. N Q D Z Z Z lA) <F 8 SO A� CSS R3S S X69 RETAINING WALL N 00 \ +I (SEE DETAIL, Z a- a- U O m I U 00 EXISTING WETLANDS STREAM TO,,REMAIN (DO NOT 3� — vu \ O LL \ j C. B.40 \ TOP= 7 83 \ INV OUT=283.2,x' \ \� 111 LF 18 N RCP @ 1.079'\ Z Z Z O L1, /yF I IV " A W H4 (4rf)? C. B. #35 TOP=286.93 INV 1N=282.04 INV OUT=281.94 O It 1"=50' Orn 0 �;-o �k c� x1 �k N 00 = N 44 o^ N = N = N a W 0p Z N O. _ n U� O U C7 Z �Ld w w Z + zz z w Y U O Z� M m H W N W� f` O zZ00 0 L Z N N= U To Z z Vw J W (n w> + 00 Z \ 1 W p7 ��LF C9 Sp + W C14� Qj f� m- Ld N H 0 0 r- N N Z a0 U J N Q D Z Z Z lA) <F 8 SO A� CSS R3S S X69 \ N 00 \ +I Z a- a- U O m I U 00 N vu 0 N O O LL (D rn N Z � Z Z Z O 0- co Qf 00,.__ Op N +I > Z } Z Qf m M 8" C-900 PVC WATER 0 45° BEND _ D 45° BEND CL. CL. \\ \ co 00 �•^ - - --- - 45° --� BEND MEND 24" r r CL. m �i Y m -i CJ C7 N W N m N \ W O J m �i j H G 0 HbAG H Q N Ln N H H Q Lu Q m0 D' N LLJ LO x } W00 F7:G_ N CO Z x— CO x �- CO Z x— U W J �Wm Op N ' 0p 00 x W ?i N 00 x W 00x x W x W af �_ J Z N 0- U 0o 00 00 Z 00 00 u- co W N U 00 0- m Z NCDOT STANDARD GAURDRAIL M.H. #8 TOP ±291.00 INV. OUT 281.10 LINF, // e I - 300 300 - 295 295 - - 290 290 - - 285 285 - - 280 280 - - 275 275 - - 270 270 - 105 LF 8" SDR 35 PVC S. S @ 5.09' TOP ±282.00 INV IN 275.85 V. OUT 275.65 20 LF DRY BORE AND JACK W/18" ENCASEMENT & 8" DIP CARRIER PIPE. 300 - 295 - WFR 300 290 - - 295 285 - - 290 280 - - 285 275 - - 280 270 - - 275 265 - - 270 260 - 10+50 11+00 11+50 12+00; 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 10+00 10+50 11+00 11+50 12+00 AND THE ANGEL SAID TO THEM, "FEAR NOT: FOR BEHOLD, I BRING YOU GOOD TIDINGS OF GREAT JOY, WHICH SHALL BE TO ALL PEOPLE. FOR UNTO YOU IS BORN THIS DAY IN THE CITY OF DAVID A SAVIOR, WHO IS CHRIST THE LORD. LUKE 2: 10-11 C. B. #35 TOP=286.93 INV 1N=282.04 INV OUT=281.94 M.H. #4 147 LF 8" SDR 35 PVC M.H. #3 TOP ±291.50 @ 5.39' (BY PUBLIX) TOP ±278.35 INV. IN 278.82 INV. IN 269.03 (#4) INV. OUT 276.82 8" C-900 INV. IN 267.23 (#5) PVC WATER INV. OUT 267.03 46 LF 8" CL 50 DIP S.S. @ 2.09' L/NE'D"Aw SFWFR 300 00 co 1"=50' Orn 0 �;-o �k c� x1 �k N 00 = N 44 o^ N = N = N a W Z a- O _ n U� O U C7 Z �Ld w w Z zz z w Y U O Z� M m H W w3: W� zZ00 0 L Z N N= U To Z z Vw J W (n w> 00 Z \ 1 W p7 ��LF C9 Sp W C14� Qj m- Ld N H 0 0 r- N N Z a0 U J N Q D Z Z Z lA) <F 8 SO A� CSS R3S S X69 \ N 00 \ - 295 285 - - 290 280 - - 285 275 - - 280 270 - - 275 265 - - 270 260 - 10+50 11+00 11+50 12+00; 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 10+00 10+50 11+00 11+50 12+00 AND THE ANGEL SAID TO THEM, "FEAR NOT: FOR BEHOLD, I BRING YOU GOOD TIDINGS OF GREAT JOY, WHICH SHALL BE TO ALL PEOPLE. FOR UNTO YOU IS BORN THIS DAY IN THE CITY OF DAVID A SAVIOR, WHO IS CHRIST THE LORD. LUKE 2: 10-11 C. B. #35 TOP=286.93 INV 1N=282.04 INV OUT=281.94 M.H. #4 147 LF 8" SDR 35 PVC M.H. #3 TOP ±291.50 @ 5.39' (BY PUBLIX) TOP ±278.35 INV. IN 278.82 INV. IN 269.03 (#4) INV. OUT 276.82 8" C-900 INV. IN 267.23 (#5) PVC WATER INV. OUT 267.03 46 LF 8" CL 50 DIP S.S. @ 2.09' L/NE'D"Aw SFWFR 300 - 295 - 290 - 285 - 280 - 275 - 270 - 265 - 260 10+00 10+50 11+00 11+50 12+00 12+50 00 co 1"=50' Orn 1'=5' �;-o Lq x1 O Lo 00 = N o^ N n Lo = N a W Z O _ n U� O U C7 Z �Ld w w Z zz z w Y U O Z� M m H W w3: W� zZ00 0 L Z N N= U To Z z Vw J W (n w> 00 Z Lu _ lA) <F 8 SO A� CSS R3S S X69 \ N 00 \ +I Z a- a- U O m I U 00 N vu 0 N O O (D rn N Z � Z Z Z - 295 - 290 - 285 - 280 - 275 - 270 - 265 - 260 10+00 10+50 11+00 11+50 12+00 12+50 BLN=C-1874 CA �. Ess/ / SEAL 19843 s � FNG I N���: AEL S�v�_�`°• G_V4/JLL /l 2/11/19 L/NES "A" "C" and "E" REVISIONS FILE NO. 2018-033 00 co 1"=50' Orn 1'=5' �;-o x1 O Lo m o^ N n Lo N W Z O _ n O U C7 Z �Ld w w Z zz z w Y U O H W w3: W� zZ00 0 L Z N N= U To Z z Vw J W (n w> 00 Z BLN=C-1874 CA �. Ess/ / SEAL 19843 s � FNG I N���: AEL S�v�_�`°• G_V4/JLL /l 2/11/19 L/NES "A" "C" and "E" REVISIONS FILE NO. 2018-033 HORZ. SCALE: 1"=50' VERT. SCALE: 1'=5' CE -08 O .ve V4� %A Ott M.H. #3 TOP ±278.35 tall* \ ♦ INV. IN 269.0 ♦ INV. IN 267.722 / X� M. H #7 W ±290.69 6 "ILOT#1 /NV. 2'9.85 ` 6'I LOT#2 /NV. 20.85 1 I � I � � I � I 295 - MG N: N:• 275 270 - 265 - 9.• 255 - 250 - 245 - NOR "oma ^ 0 0 M. H. #2 TOP ±268.00 INV. IN 257.30 INV. OUT 257.10 E� o�# 0 — / 35 PVA q �� _ ✓ / - s - 3SEWEF�-EA�E1v1EtdT= — �- — — 96 LF SD 8"' R- �5 PVC ®,1.79up— /17 _— �i jr� �✓ j��—�/-- ___�— ✓-C� — �--/II/Il l /I 1, \\, ��\�� _ _/ - ONE i e L //ZON BUFFER O) HORZ. SCALE: O VERT. SCALE: 1'=5' COW LIC) BOX 2A\ (5E� DETAIL) \ \ TOP 2Z7. 78 ` \ "" W INV. -IN 267.21 \ \ 24-,I(VV. IA -2,70.79 P9 Z \24 " IAII.,OUT 2`70.76 N \ M. H. #2 TOP ±268.00 INV. IN 257.30 INV. OUT 257.10 E� o�# 0 — / 35 PVA q �� _ ✓ / - s - 3SEWEF�-EA�E1v1EtdT= — �- — — 96 LF SD 8"' R- �5 PVC ®,1.79up— /17 _— �i jr� �✓ j��—�/-- ___�— ✓-C� — �--/II/Il l /I 1, \\, ��\�� _ _/ - ONE i e L //ZON BUFFER O) HORZ. SCALE: O VERT. SCALE: 1'=5' W 0 0 O O W N z_ r- P9 Z 1�j 06 N O 06 2 N2 N S N a 2 a. D V) N S :2 N W W a- ci a - H U)H (f) Lu 350 LF 8" Sp 38 PVC SEWER ® 1.09 -_ `--- RCP ---------- -- _, 36g SDR 35-000 PV SFR 1 $rr40 MIN. CL. - L WATER _- \- -j U 8" SDR VC SEWER ® 0.690 SDR--- ® 1.79,• ------ _- \`/ 396 LF 8,. SDR 35 PV SEWER ®2.09,' cc M '(-I ' r�Z5 r N N N 00 r- Lc) � 23 OJ p 0 Lo L o Lq 04 Pr) O O O >> N N N �. N N N 0 -Z Z Z 0 Z 0 Z Z 0 Z > > Z Z > Z > Z > Z > > > Z Z Z > > Z Z 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00 AND THE ANGEL SAID TO THEM, "FEAR NOT: FOR BEHOLD, I BRING YOU GOOD TIDINGS OF GREAT JOY, WHICH SHALL BE TO ALL PEOPLE. FOR UNTO YOU IS BORN THIS DAY IN THE CITY OF DAVID A SAVIOR, WHO IS CHRIST THE LORD. LUKE 2: 10-11 20+50 21+00 - 295 f :" :M - 275 - 270 - 265 mr4*10 - 255 00 (D orn �00 x1 O m `o o^ N N W z O m �10 HORZ. SCALE: 1"=50' VERT. SCALE: 1'=5' U 0 z Ld W W z_ z z Z W cn � Y O 0 W W tl ? L Pm :_rte W 1 KH_ BLN=C-1874 , ,I CARO"-"" �. Ess/ / SEAL 19843 s � �'CHAEL S�v�_�`°• 11' 11 �.Ikki I 2/1/19 SACM - 250 SEWER LINE "B" - 245 MrZON 21+50 22+00 22+50 23+00 23+50 24+00 24+50 25+00 REVISIONS FILE NO. 2018-033 HORZ. SCALE: 1"=50' VERT. SCALE: 1'=5' CE -09 300- 00- 295- 295- 290- 290- 285- 285- mm :• 275 - 270 - 265 - 260 - 255 - 250 - 245 - 240 - EX. M. H. EX. TOP 253.95 EX. IN 245.50 EX. OUT 243.23 PRO. INV. IN 245.50 I h I N I co /�pR 35 PVC 2. / 396 LF $ SEWER_'-BpfP EASEMEvT�— — _ 1_ —/— 7 DTII �l,l I \\ i 1 7 \ \ / � 1• I I I j 1 I � / 0% 16 @3'� — !� / // / / FES/#47 / // / / / /l IIW IN -255.001- M. 155.00i M. H. #1 TOP ±258.00 INV. IN 249.18 INV. OUT 248.98 L)NF I w 11 - Sj ffff)? REMOVE AND REPLACE EXISTING FENCE AS NEEDED TO INSTALL SEWER \1 23+50 24+00 24+50 25+00 25+50 26+00 26+50 27+00 27+50 I / II / I/ 11 - 300 - 295 - 290 - 285 - 275 - 270 - 265 - 260 - 255 - 250 - 245 - 240 AND THE ANGEL SAID TO THEM, "FEAR NOT: FOR BEHOLD, I BRING YOU GOOD TIDINGS OF GREAT JOY, WHICH SHALL BE TO ALL PEOPLE. I FOR UNTO YOU IS BORN THIS DAY IN THE CITY OF DAVID A SAVIOR, WHO IS CHRIST THE LORD. LUKE 2: 10-11 .z W W z Lu 0 U CD Z_ Cr w w z (D z w cn Y 0 O BLN=C-1874 Z 0 Q V � O y � O 2 ct �w Qftv CA �. o'EssR• / '�. SEAL 19843 s � 01AEL S�v�_�`°• ee 2/1 SEWER LINE 'B" CONTINUED f REVISIONS ■ FILE NO. 2018-033 HORZ. SCALE: 1"=50' VERT. SCALE: 1'=5' CE -10 0 0 �cy) Lo = LE N (n F) L(i a - (n H W H \ \\ 0 po ♦\C, N N z� —D \\Z > —Z \ 396 LF 8„ Sp R \-� Ll I x 35 P VC SEWER 2.Oq" a 116 LF SSR 35 P VC SEWER 0000 �06 N N Z H > Z_ O Z 23+50 24+00 24+50 25+00 25+50 26+00 26+50 27+00 27+50 I / II / I/ 11 - 300 - 295 - 290 - 285 - 275 - 270 - 265 - 260 - 255 - 250 - 245 - 240 AND THE ANGEL SAID TO THEM, "FEAR NOT: FOR BEHOLD, I BRING YOU GOOD TIDINGS OF GREAT JOY, WHICH SHALL BE TO ALL PEOPLE. I FOR UNTO YOU IS BORN THIS DAY IN THE CITY OF DAVID A SAVIOR, WHO IS CHRIST THE LORD. LUKE 2: 10-11 .z W W z Lu 0 U CD Z_ Cr w w z (D z w cn Y 0 O BLN=C-1874 Z 0 Q V � O y � O 2 ct �w Qftv CA �. o'EssR• / '�. SEAL 19843 s � 01AEL S�v�_�`°• ee 2/1 SEWER LINE 'B" CONTINUED f REVISIONS ■ FILE NO. 2018-033 HORZ. SCALE: 1"=50' VERT. SCALE: 1'=5' CE -10 ............................................................................................................................................................................................................................................................................................................................................................................................................................................................ . \ 1 __ \ \ \ \\ \\\ EX POND - 1 \ \ \ \ / \ \ NI \\` l ` \\ •I \` \♦ \ `\ --- \� / \ `�` `. I / / 1 (Y 1 I `------- / \\ ` \ \\ �\ ��--- `� �`�\ '`� / 550 \ /' _ \\` \` I I 1 ------------------\�\\\ �`\ _`� /% /moi - /moi' �\\` \\ NNN \ / / / 1 NNN NN \\ \ \ \ \ -,t �,po / ---280----------'' Zkx / I \ `\ ----------------- \ `\ ` \ \ `\ `, % \\\ 168 LF 48" ---------' ----- `-- 280 \\ % RCP ® 1.09 `\ FES #1 INV N265. / \ W/6'FES =13 \ \ a,8 �N\\\ .- - N- •\`r%�/ III\r�T�.Ta'1� _ � \\ \\ \\ \I \\ \ i - _ 268 �•� \\\ I 1 / / / ; -- \\ _--- - \`\ \\ 1 \\ /i \ \`\ \ \ \`, ' \� \�'`_�` ���'Q_�- � __ � '� // ; ��/ k/ /// ill Ill 1 % � 1 _.�_•� - -- -- -_ _ `\ \ \`\ /� \\ \\ \\\ -.\\ `\ \ `, OUTLET PROTECT/ N - CLASS B RlP P \` \\ N`. i \ �\ \\ \\ 1 \\ \\ \\ \, \ \\� 'SEQNG WIDTH 12� . " - - VEGETATED___- `'\ \\ \\ \\ l\ \\ \\ \\ \ \`� `�. ENGTH 4 DTH 12' "� SHELF //- \ 17 \ \ \ \ \ \ \ � __ -� PROPOSED \ -_ �,_,,�� . -Y h i \ \ \ \ \\ \\\ \� \, \• EXISTING DITCH ® 1 11% ` ` \ \ \ `\ �'i FAN► \ / F, „ / / / / / I - , - -I - % �TLI\N�S O Mplf\1 \ \ .< \ c --- ., �- . i �. �. ,` L _'N 1 \ \ \ \\ W T RE /\ \L \ --- - - `�-- VEGETATED/ I I \ \ 1 \ \ \ \ 1 V /- \ \ �__-- -__� ----�\ �,�� SHELF I I 1 D/ #46 I\ \ `\ `\ \ ``_- ` / 1 TOP=265.00- % INV IN (12 )=257.00 \�� \ \ \ \ \\ ,'`� . ' _� '`. ----- ,� / INV IN (6)=262.00 O `� INV OUT=255.73A. % \, ��� / ,Y 72 LF 48" O RCP ® 1.09',- %`. \ i ` CLASS B RIP - / �, W16' FES \ EMERGENCY Z_� \ \ \ \�� - \ �\\\�� - /�/�/%\` �LWAr 266.00 / / // I / / I \�� \ \ \ \ \ \ \ \ \ �`�, \\ 1� "� �G ,., �\\\ � _` ✓� / 11ill 1+1 1 \ \ \ `\ `\ \ \ \ \ ` \, . ? .\ G�F\\� \ �� /i/% I y• -I II �Ijlll-- �'��` '---' th / / r - � - 7 - ► F \ l \ \ �. __ \ UD/ N.~"��. _---------- \ \\ IN \ N NN ^__ \ \ \ ` \ . \ \ \'\ \ �' �� . . \ -- '�� _ _ (2) 12'x12 \ \ \ \\ I _ \ �\ N \ \-- - N \ `N �� ` ` ` `�� �- _ - FES 47 l \ \ \ \ _ �_ �\ \\ �\ �\ �\ �\ �\ �\\ N� �\ \\ \\ --�ti. ANTI -SEEP I \ \ \ \ \ \ \ \kz \ \ _ �QL4AR 255 /NV [N=255. 00 ( / \-_,\ \ \ - `N NN\ NN\ \ - \ NIN / \ \ NN \ \ \ \ \ \ �- �_ \ \ \ 1 \ 1 \ / / \ - \ \ I 1 _ CLASS 1 RIP RAP ` \ `. \ \ \ \ \ \ \ �\ \ \ 1 \I 1 l \ \ ` --- BEGT NG9 TE 12QN SCALE: 1" = 60' /" '-2 -- \` `\ \` \` \ .\ \ \ \ \\ \ \ \ \ i \/ 0 60 120 150 180 210 240 /_ \ \ \ \ ` \ \ \ - \ .\- \ �� • \ \\ \ \ \ \ \ \ .\ \ \ - \ \ \ \ ZF/ •o _ \ \ �\ \\ \\` \ �\ �\ \ \ \\ \ \\ \ \ \ \\ -.�_ ��._� �� 1/ \ \\ _ \•END/NG WIDTH 3 / ------ \ \ . - '•- `- ` \ \ \ ` \ \ \ \ 1\ ZENGTH J5,---- \ / 2.80 FT. FREEBOARD t 3 �1 2 �1 BOTTOM OF FOREBAY 254.00 1 YEAR STORM 264.70 7 1� 10 YEAR STORM 266.25 PERMANENT POOL 262.00 BOTTOM OF POND 257.00 WET DETENTION POND PROFILE NOT TO SCALE 25 YEAR STORM 266.55 TOP OF DAM 267.00 TOP 265.00 3 2'x3' DROP INLET WITH TRASH RACK 36" RCP INV. OUT 255.73 W/ ANTI SEEP 2 6:1 VEGETATED SHELF @ PERMANENT POOL COLLAR 4' 6" PVC ORIFICE INV IN. 262.00 W/90° ELBOW Wet Detention Pond Construction Sequence 1. Contractor shall excavate the bottom of the pond to the depth of the proposed basin. 2. Excavated material must be disposed of in an approved off-site location. 3. Care must be taken to prevent any sedimentation/re-sedimentation during this process, as sediment deposits in the bottom of the pond may affect the depth. If any sedimentation occurs during this process, Contractor shall remove sediment immediately. 4. Contact Stocks Engineering @ 252-459-8196 to inspect excavated pond before continuing construction. 5. Upon approval of Stocks Engineering, continue constructing pond per details. Establish appropriate permanent vegetation around pond as soon as possible. 6. Contractor to compact bottom and side slopes to ensure a maximum infiltration rate of 0.01 in/hr. 7. Ensure side slopes do not exceed 3:1 and that topsoil is placed a minimum of 6 inches deep on side slopes and wetland shelf. 8. Upon completion of pond construction, remove sediment from silt fence and dispose of at an approved off-site location. Plant vegetated shelf and seed and mulch side slopes. 9. Contact Stocks Engineering @ 252-459-8196 to inspect completed pond before placing pond in service. 12" PVC ORIFICE INV I N . 257.00 W/MJGV INSIDE BOX BOTTOM OF BOX � 254.70 FILL BOTTOM W/ CONCRETE TO 255.50 LEAVE ROOM AT INV. FOR INSTALLATION Behold, a virgin shall be with child, and shall bring forth a son, and they shall call his name Emmanuel, which being interpreted is, God with us. Matthew 1:23 STAGE/STORAGE TABLE STAGE ELEVATION CONTOUR INCREMENTAL TOTAL AREA (SF) STORAGE (CF) STORAGE (CF) 0 262.00 32,759 0 0 1.00 263.00 35,873 34,316 38,819 37,346 42,316 40,508 34,316 71,662 112,229 2.00 3.00 264.00 265.00 4.00 266.00 46,595 44,456 156,685 5.00 267.00 50,778 48,687 205,371 5.50 T267.50 56,334 I 26,778 232,149 VEGETATED SHELF LANDSCAPE PLAN ALL PLANTS SHALL BE 3" CONTAINER PLANTS. BELOW PERMANENT POOL Botanical Name Common Name QTY• Iris virginica Blue flag iris 278 Ludwigia spp. Primrose willow 278 Peltandra virginica Arrow arum 278 POND SLOPES LANDSCAPE PLAN POND SLOPES SHALL BE VEGETATED WITH BERMUDA GRASS AT A RATE OF 60 LBS. PER ACRE. NOTE: CONTRACTOR TO COMPACT BOTTOM OF POND TO ENSURE INFILTRATION IS LESS THAN 0.01 IN./HR. orn �00 xl 0 mLO C5^ N LON W z 0 IL BLN=C-1874 CAo �\ Q` o'�ssR• i O . ' F 09.• �L9 Q� SEAL � = 19843 '91AE'L S�OG AQUA SEWER DETAILS REVISIONS FILE NO. 2018-033 0 1 0 NONE U C7 z E W toW z z W Z (n C) U C) WW W W � z00 0 L • r z N V= U �Z Z�w J W ( ) W = ¢' (n 00 z BLN=C-1874 CAo �\ Q` o'�ssR• i O . ' F 09.• �L9 Q� SEAL � = 19843 '91AE'L S�OG AQUA SEWER DETAILS REVISIONS FILE NO. 2018-033 HORZ. SCALE: AS NOTED VERT. SCALE: NONE CE -11 N 27&82 NIN .5.44 Z N r (S�,jl~ _ _ /_�` - 4' CONCLU MH53 P s D 1 a_ o P 1 _---__ _—_— 4 1_ _ ===___ ------------ ~ D x �, m �4 _- `z -s LL Cr I- E N ---------______-- s9� - �= `__-=�— \\ ` \------- DIGITIz' D 3 sl N 3 m �'� ------------------- ---�-- CZA 10+oa_— \- _ ss��=�� _ �> = _ " _— \ ` A K E L I $S-5 m INT RS lO v i�> E .0-6 ° _---___- = f \ S7 1 �ssg� - /� — ��/ice- _ - _� — __1 \-- ---- 1SFD i/ mm C, 42 ZIN -'' s''- _------ __,__; -:71 CONC PON .+.90 POND / T HP EROSION LEGEND / _--- ,,, � , ,� "� � x � -' r 2 4. 8 \ - p ,� 2.s 2• 1 1` ' \ \\ \\ t ~`. \ \ \ �\ \ \ \ I - r - 30 05 - _ HP rc 2s3. - 92.s 29 s I \ \ \ - _ \ \ \ \ \ I \ , ■--F■ SILT FENCE 93.\ 1E s 9 2 \\ \\\ \\ \, -_ \ \\ \\ \\ \\ \\ \ \ 1 ■-�■ SILT FENCE OUTLET e \ \ \ \ \ \ \ \ \ \ , \ \ —I CONSTRUCTION ENTRANCE 300 2s2• s L 2 _ _ - _ / ' / / / 290/ I g \-�\ \ \ \ \ \ \ \ \ \ \ \ \ \ I \ \ ~ i PS PERMANENT SEEDING 2 \ I \ 2/8g \ 2 \ _ '\ \ \ \ I / / \ \ \ I \ \ \ H --0-TD--0-TD IS TIS TEMPORARY DIVERSION SIL T \ ` / / / l I \ \ \ '\ \ \ z ; W/ NAG DS75 EXCELSIOR MATTING FENCE ,//__' � I \---295---__---_ _` � \7 � \, \\ 2 � ■ `_ _ 89 \ ` OUTG\ET \\ ��1. // / / / / i i I 1 \, � � � \ / / / /7'Pj T r 28 _ / 2 \ SKIMMER SEDIMENT BASIN / \ / / G+ ------------- _ I _ I l \ 1� /' ,+' o 5� '- g`l• _ - fis 2s - / o D I / f / r /' / I I I \ / / �/ I I I - _ / \ I / - _ - - - - - - ' _ _ _ - - - ` / 1 I I ( / / / I ) \ 1 \ I • TOTAL AREA DISTURBED = 19.05 Ac. 290 ARC FILTER INLET PROTECTION SIL T / I \ / I\., \ I tr 19+ 1� ,FENCE/ / I \ l l / / I CONCRETE TRUCK WASHOUT I / 1 / � ' / � \ � / I rc I \ \ \ p rc 2_ ° - \ + IDU R -A � — \ _ 1.40 _ — 1.2 1 1 1 / / + I / / / / I T ' \ \ _ _ _ _ " I I 2g \ \ I \ I I I I 1 / / / / ` ; 1 / \ \ 1 \ y�►� NCDOT WATTLE \ \\ / // / ■ 4 ■ \ I I _ "' 291.0 T 2g1.0 - — I \ `!, I \ \ \ \ \ \ \ \\ I I f \ \ \ CLASS B OUTLET PROTECTION 1.4 291 \ \•: •\• 1.G EXCELSIOR MATTING 7 / \r \ - \ \ (NAG 75, 6' WIDE) ■ HARDWARE CLOTH OpMENT Lod .. INLET PROTECTION g0o\ f VE \ -/ \ \\ \ \ \ 1 rc \ }p / / I 1 / DE \ I \ \ \ \ I 210 _ S / / \' • \ \ 1 -PAVBm ------285—__- / .10 _ _ /' // I \ \ \\, \\ \ \ \ 1 291 e \\ \ 1 \ \ I \ cs �\ \ / I a T 290 287.50 ■ /' \ / l \ \ \ \ \ \ \ .�6,r0-- \ \ \ I I \ \ �.�% � � I � j_c 86.30 ■ � � /' / \\\ \ \ \ \ I '; \ 1 \\ \\ \\ \ \\ 1\ � _ I I I / % \\ Ql� ��'� \ •� RA,e � \ \ � � .. _285 -' \\ \ \ \ 1 1 63 \ \ \ \ \ \ \ I �Q�)✓ // (� \ \ rc 2$ 6 .SAP I ?-2s�.s3 _ _ 5 fi \ - - \ _ r o \\ \\ \\ r'�o s I /, 67 /Aa" \\ �1� �; - m _ \ ... _ 2 7 / / Q SEDIMENT BASIN (/ �1NI 6 _ _ -> ; -4 TOP LENGTH = 70 ORIFICE Sf'1& 1.,4 1 1 TOP WIDTH = 40 � WEIR WD 774 = 1-0!, BOTTOM LENGTH = 60' WEIR DEPTH =0.5 \ 1 \ \ I I \ - \ 2 v SSP- o _ / o,► BOTTOM WIDTH = JO BAFFLES = 3 R \ \ 1 I ?g TO G.J.EId- 1 \ \ - _ 4 \ o TOP W1L TH = 65 \ \ \ - - _ _ - - \ \T _ % - - _ _ _ BASIN DEPTH _ 2.5' SIDESL OPES 2. 1 ` - - - - - \ \ \ \ - - SKIMMER SIZE - 2 OT TOM LENGTH = 11 \\ \\ \\ \ \ \\ \ \ \ \ I \ I \\ \ \BBOTTOM WIDTH = 55� \ o \ \ \ \ \ ASIN DEPTH � 2.5 SKIMMER SIZE \\ \ \ \ \ \ \ x\ ORIFICE SIZE = 1.6\' til \ \ / --- ---- \_ -- woo / ♦ \\/ WEIR WIDTH = 25� \ h \ \ \ 5 \ --- ,\ -----� WEIR DEPTH =0.5 \� \ \ \ - \ BAFFLES = .tip \ (Dii7 NOT 0 \\ �� - - - - - _ 2 \ _ _ 280 SIDESLOPES = X1-1. \ \\ \ \ Gi \ �\ oma,.. _\\ --�� 2S0\ / \\ 1 1 I 1 \\ \ \ \ ti S/LT )FENCE 285 - _ \ \ \ \ \ e 1 ♦ o - 1 \\ \\ \\ \\ \ \\ oo\\\ --\ 2�0 �� .■. - - - o / / / I I \\\ \ \ \\_♦ UT1 OFF \\ \\ \ x`o. \ \ �� I \ ?l \ \\ \\ \\ \\ �,� \\ \ \ \ \\ \\\\ _ \ e \\ / --- X/ // // \Lo l l l l / 1 .(. 1. .r-- J \ \ \ \ I 1 \ \ \ \ \ \ \ \ \ �\ \; \ e\ \ \ ��__= 265, \� ♦ - - // / / / / ` _ Y/ // // //( 1 , . \-� // / o'/ //. y . 1./. \ wok ' l l / i v I \ �\ \ \ \ \ \ \ / .1 l r / 5'lL T / I I I I \ o\ \ \ \ �I�HET FENCE / / // / / I I I \ \ \ \ \ \ \ \\ / / �, ��_ / 1 / \ 1 I \ \ f / / / / I I I \ \ \\ \ \\ \ �`` _ /-�\\\ \�/'.�l\1)/ .� ,, �s� / ` �� _ ' 0�/- \ OUTLET / �\ \ \ \ \ \ \ \ \ / _ - /' - \ \ _ ■ i'/r. Notification of Land Resources Sediment and Erosion Control Self Inspection Program: \ \ \ \ \ \ \ \ \ \ \ \\ \'- _ — _ _ _ / - - -/ - \ \ \ \ \ \ \ - _ ---� 6 FENCE \ / . \ The Sedimentation Pollution Control Act was amended in 2006 to require persons responsible for land disturbing activities + \ \ 1 \ \ � \ \ \ \ \ \ \ \ \ \ \ \ � _ — _ _ — �, \ � /.,, •/ • • i • • 1 \ I \ \\ \ \ \ OU \ / . inspect a project after each phase of the project to make sure that the approved erosion and sedimentation control plan is � being followed. Rules detailing the documentation of these inspections took effect October 1 2010. To simplify documentation of Self -Inspection Reports and NPDES Self -Monitoring Reports, a combination form is now availible. The new form was developed to satisfy the requirements of the Sedimentation Pollution Control Act and the NPDES Stormwater _ Mineral \ \ \ \ \ \ \ \ \ \ \ \ �. \ \ \ \ _ / Permit for Construction Activities, NCG 010000. Beginning August 1, 2013, the Division of Energy, , and Land \ \ \ \ I \ \ \ — _ _ — _ \ \ \ \ \ \ �� \ \ \ \ \ \ \ \ \ \ \ \ \ \ e\ ` _ ' , Resources is responsible for administering both the SPCA and the NPDES Stormwater Permit for Construction Activities, NCG \ 010000. The combined form should make it easier to comply with self -inspection requirements. \ \ ?j The Combined Self -Monitoring form is availible as a PDF and Word document from the Land Quality web site, \ \ \\ _ — _\ \ \ \ _ — — — — _ _ ` \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ ~ ,� \ \ 1 \ I' \ \\\\ o _ �' / / / / ( 1 1 htt : /oortal.ncdenr.or web Ir erosion If you have questions, please contact the Land Quality Section at a DENR Regional Office. SCALE: 1' = 60' \ \ \ \ \ _ _ \ \ \ 275\ Y q Y 9 e - — - \ \ � � �(50 \ \ 0 60 120 150 180 210 240 AND THE ANGEL SAID TO THEM, "FEAR NOT: FOR BEHOLD, I BRING YOU GOOD TIDINGS OF GREAT JOY, WHICH SHALL BE TO ALL PEOPLE. FOR UNTO YOU IS BORN THIS DAY IN THE CITY OF DAVID A SAVIOR, WHO IS CHRIST THE LORD. LUKE 2: 10-11 O m 00 XI O mIn 0 N N w Z O �10 HORZ. SCALE: 1"=60' VERT. SCALE: NONE U 0 z _ [ifw t� w V z_ U Z z w Cn � Y U O W w3: W � z00 0 L • �00 z (N (n= U Z z �w J () W w> z 0000 BLN=C-1874 CARO ..o•EssR i =O .� F 0 y� Q < SEAL 19843 G � ''0/1AEL �•�'Qe0 e 12/21/18 EROSION CONTROL PLAN REVISIONS FILE NO. 2018-033 HORZ. SCALE: 1"=60' VERT. SCALE: NONE CE -12 EROSION AND SEDIMENTATION CONTROL NARRATIVE PROJECT DESCRIPTION The purpose of this project is for the construction of a Publix Grocery Store and surrounding roads. The project Is owned by Flowers Plantation. The site is currently a farm field. Approximately 19.05 acres will be disturbed during construction. The maximum fill will be 6-8 feet. Thepproject is scheduled to begin construction in Early 2019 with project completion and final stabilization by Summer 2020. The erosion and sediment control program for this project will include the installation of a suitable construction entrance, skimmer basin, temporary diversions, NCDOT weirs, silt fence, with temporary and permanent seeding. ADJACENT PROPERTY The adjacent property is agricultural. SOILS The soil at this site is a sandy clay. EROSION AND SEDIMENT CONTROL MEASURES All vegetative and structural erosion and sediment control practices shall be constructed and maintained by the contractor according to these plans and specifications and the minimum standards of the Dept. of Environmental Management Land Quality Section and Town of Sharpsburg. The contractor shall also follow any additional requirements as outlined by the Project Engineer. Structural Practices 1. Vehicle wheels shall be clean when leaving the site to prevent the tracking of mud on paved roads. 2. Construction Road Stabilization: Construction traffic shall be limited to stabilized areas. At a minimum, a temporary gravel construction entrance shall be provided as shown on this drawing. 3. Silt Fence: Silt fences shall be provided where shown and as needed on the site plan. These barriers shall be used to contain sediment. 4. Rip Rap/Gravel Filter Sediment Basins: Construct basin to the shape and dimensions shown in the details. The basin is to be placed below the existing ditch flow line by 2' with the berm built above as dimensioned. Vegetative Practices (Ground Stabilization) Site Area Description: Stabilization Time Frame: Stabilization Time Frame Exceptions: Perimeter dikes, swales, ditches & slopes. 7 Days None High Quality Water (HQW) Zones. 7 Days None Slope steeper than 3:1 7 Days None Slopes 3:1 or flatter. 10 Days 7 Days for slopes greater than 50 feet in length. Seeding Schedule Ongoing Activity. Land left exposed shall be planted or otherwiase provided with temporary ground cove, devices, or structures sufficient to restrain erosion within the applicable time period after completetion of any phase of grading or period of inactivity as follows. seven (7) days for steep slope or inclination. Ten (10) days for a moderate slope, fourteen (14) days for land with no slope or inclinination. For purposes of this section, a moderate slope means an inclined area, the inclination olf which is less than or equal to three (3) units of horizontal distance to one (1) unit of vertical distance, and a steep slope means on inclined area, the inclination of which is greater than three (3) units of horizontal distance to one (1) unit of vertical distance. No other criteria apply. Completed Activity. For any area of land -disturbing activity where grading activities have been completed, temporary or permanent ground cover sufficient to restrain erosion shall be provided as soon as practicable, but in no case later than seven (7) days after completetion of grading. Management Strategies 1. Perimeter measures are to be installed prior to grubbing or grading. 2. Tail Ditches shall be stabilized immediately following their construction. As an alternate, rock check dams may be provided at their outlets and/or the terminal downstream end of disturbance until ground cover is implemented. 3. Stockpile and/or waste areas must be maintained within the limits of the areas protected by the T measures and otherwise temporarily seeded if to be left stockpiled over 14 days. 4. Construction shall be planned so that grading operations can begin and end as quickly as possible. 5. Silt Fences shall also be installed prior to or as a first step in construction. 6. The Contractor shall be responsible for the installation and maintenance of all erosion and sediment control practices. Vegetative Ground Cover Immediately following grading, all areas shall receive either permanent or temporary seeding, as applicable, as follows: TEMPORARY SEEDING SPECIFICATIONS BETWEEN MAY 1 AND AUGUST 15, ADD 40 LB/ACRE GERMAN MILLET. PRIOR TO MAY 1 OR AFTER AUGUST 15, ADD 120 LB/ACRE RYE (GRAIN). FALL IS BEST FOR TALL FESCUE AND LATE WINTER FOR LESPEDEZAS. OVERSEEDING OF KOBE LESPEDEZAS OVER THE FALL SEEDED TALL FESCUE IS VERY EFFECTIVE. USE UNHULLED BERMUDAGRASS SEED IN FALL. SOIL AMENDMENTS APPLY LIME AND FERTILIZER ACCORDING TO TESTS, OR APPLY 4,000 LB/ACRE GROUND AGRICULTURE LIMESTONE AND 750 LB/ACRE 10-10-10 FERTILIZER MULCH APPLY 4,000 LB/ACRE GRAIN STRAW, OR EQUIVALENT COVER OF ANOTHER SUITABLE MULCHING MATERIAL. ANCHOR MULCH BY TACKING WITH ASPHALT, ROVING OR NETTING. NETTING IS THE PREFERRED ANCHORING METHOD ON STEEP SLOPES. MAINTENANCE REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. PERMANENT SEEDING SPECIFICATIONS SEEDING MIXTURE SPECIES RATE (LB/ACRE) TALL FESCUE 200 CENTIPEDE 50 NURSE PLANTS BETWEEN APR. 15 AND AUG. 15 ADD 10 LB/ACRE GERMAN MILLET OR 15 LB/ACRE SUDANGRASS. PRIOR TO MAY 1 OR AFTER AUG. 15 ADD 25 LB%ACRE RYE (GRAIN). SEEDING DATES BEST POSSIBLE EARLY SPRING: FEB. 15 -MAR. 20 FEB. 15 -APR. 30 FALL: SEPT. 1 -SEPT. 30 SEPT. 1 -OCT. 31 SOIL AMENDMENTS APPLY LIME AND FERTILIZER ACCORDING TO SOIL TEST, OR APPLY 4,000 LB./AC. GROUND AGRICULTURE LIME STONE & 750 LB./AC. 10-10-10 FERTILIZER. MAINTENANCE IF GROWTH IS LESS THAN FULLY ADEQUATE, REFERTILIZE THE SECOND YEAR. ACCORDING TO SOIL TESTS OR TOPDRESS WITH 500 LB/ACRE 10-10-10 FERTILIZER. MOW AS NEEDED. REPLACE, FERTILIZE, AND MULCH DAMAGED AREAS IMMEDIATELY. Maintenance 1. Reseed and mulch bare spots larger than 9 square feet (limited to 5% maximum of site area.) 2. Maintain all seeded areas until uniform stand Is acceptable. 3. If growth is not established by final project inspection, continue specified attention until the stand is acceptable. 4. Correct and repair all undue settling and erosion within 1 year after final inspection. 5. Remove from the site, all erosion control structures after complete stabilization at end of construction period. 6. Remove silt from sediment pits and from behind check dams when silt is within half depth of the pit or spillway. Dispose of in an area where silt cannot re-enter pit / trap. Calculations The practice utilized for the proposed site did require formal calculations. Calculations have been provided. Owner Rebecca D. Flowers 4880 NC 42 East Clayton, NC 27527 Phone: 919.553.3084 Maintenance Notes: 1. Follow chart for timelines of when to apply temporary seeding. 2. Maintain all erosion control measures daily and reseed disturbed areas as needed. 3. Inspect all erosion control measures weekly and after each rainfall event. Repair as needed. GENERAL NOTES: 1. All Stockpile areas shall be a minimum of 100' away from surface waters and inside the perimeter EC Measures. 2. All Concrete Washout areas shall be a minimum of 100' away from surface waters and inside the perimeter EC Measures. 3. If an offsite soil spoil or borrow site is utilized, then the disturbed area for the spoil/borrow site must be included in the land -disturbance plan and permit unless the spoil/borrow site already has a land -disturbance permit. Construction Sequence 1. Obtain Land Disturbing Permit and placard, and post the placard on site. 2. Notify Johnston County prior to beginning construction. J. Install construction entrance, silt fencing, sediment basin, and other perimeter erosion control measures as specified in the plan. Temporarily seed once installed. 4. Contact Johnston County for an inspection. 5. Contractor is responsible for meeting NPDES requirements to maintain rain gauge, records of self inspection, permit, and S&E plan on site. 6. Begin grading of site in accordance with the approved S&E control plan. 7. Provide all disturbed areas with ground cover as per the seeding table and timeline, after completion of any phase of clearing, grubbing or grading. The seeding, seedbed preparation, mulch and/or rolled erosion control product installation must be in accordance with the seeding schedule provided in this S&E plan. 8. At the conclusion of building or if land -disturbing activity is stopped temporary or permanent vegetative cover shall be installed in accordance with this plan. 9. Stockpile shall be respread over site or disposed off-site in a permitted facility. 10. All measures shall remain until permanent vegetation is established. 11. Permanent groundcover shall be established in 15 working days or 90 calendar days, whichever is shorter. However, NPDES groundcover requirements take precedence. 12. Remove all erosion control measures after Johnston County approval of permanent stabilization. CURBSIDE PLAN FILTER SOCK CATCH BASIN CURBSIDE SECTION FIVA68 SOCA INLET PROTECT/ON (INSTALL ONCE CURB OR SIDEWALK IS POURED) NOT TO SCALE CONSTRUCTION SPECIFICATIONS: 1. Inlet protection shall be laced at locations indicated on plans as directed b the Engineer. Inlet protection should p p p Y g be installed in a pattern that allows complete protection of the inlet area. 2. Installation of curb Inlet protection will ensure a minimal overly of at least 1 ft on either side of the opening p p p g being protected. The Inlet protection will be anchored to the soil behind the curb using staples, stakes or other devices capable of holding the Inlet protection in place. 3. Standard Inlet protection for curb inlet protection and curb sediment containment will use 8 in diameter Inlet protection, and drain inlets on soil will use 12 in or 18 in diameter Inlet protection. In severe flow situations, larger Inlet protection maybe specified by the Engineer. During curb installation, Inlet protection shall be compacted to be slightly shorter than curb height. 4. If Inlet protection becomes clogged with debris and sediment, they shall be maintained so as to assure proper drainage and water flow into the storm drain. In severe storm events, overflow ofthe Inlet protection may be acceptable in order to keep the area from flooding. 5. Curb and drain Inlet protection shall be positioned so as to provide apermeable physical barrier to the drain itself, allowing sediment to collect on the outside of the Inlet protection. 6. For drains and inlets that have only curb cuts, without street grates, a spacer is required in order to keep the Inlet protection away from the drain opening. This spacer should be a hog wire screen bent to overlap the grate opening and keep the sock from falling into the opening. Use at least one spacer for every 4 ft of curb drain opening. The wire grid also prevents other floatable waste from passing over the Inlet protection. 7. Stakes shall be installed through the middle of the drain Inlet protection on 5 ft centers, using 2 in x 2 in x 3 ft wood stakes. 8. Staking depth for sand and silt loam soils shall be 12 in and 8 in for clay soils. MAINTENANCE: 1. The Contractor shall maintain the Inlet protection in a functional condition at all times and it shall be routinely inspected. 2. If the Inlet protection has been damaged, it shall be repaired, or replaced if beyond repair. 3. The Contractor shall remove sediment at the base of the upslope side of the Inlet protection when accumulation has reached 1/2 of the effective height of the Inlet protection, or as directed by the Engineer. Alternatively, for drain Inlet protection, anew Sock maybe placed on top of the original increasing the sediment storage capacity without soil disturbance. 4. Inlet protection shall be maintained until disturbed area above or around the device has been permanently stabilized and construction activity has ceased. 5. Regular maintenance includes lifting the Inlet protection and cleaning around and under them as sediment collects. 6. The filter mediawill be removed from paved areas or dispersed on site soil or behind curb once disturbed area has been permanently stabilized, construction activity has ceased, oras determined by the Engineer. 11%AO WA,FCL4#1/ ORA!/EL /NLETPROTECT/ON NOT TO SCALE (CONVERT TO FILTER SOCK ONCE CURB OR SIDEWALK IS POURED) STANDARD METAL POSTS 2'-0" IN GROUND GALVANIZED HARDWARE WIRE EXTENDS TO TOP OF BOX MAINTENANCE. INSPECT THE BARRIER AFTER EACH RA/NAND MAKE REPAIRS AS NEEDED. REMOVE 0 SEDIMENT AS NECESSRY TO PROVIDEADEQUATE STORAGE VOLUME FOR SUBSEQUENT o RAINS. WHEN THE CONTRIBUTING DRAINAGE AREA HAS BEENADEQUATELY STABILIZED, REMOVEALL MATERIALS AND ANY UNSTABLE SOIL, AND EITHER SALVAGE OR DISPOSE 8 p OF IT PROPERLY. BRING THE DISTURBED AREA TO PROPER GRADE, THEN SMOOTH (meq AND COMPACT IT APPROPRIATELY STABILIZEALL BAREAREAS AROUND THE INLET. 9l o CONCRETE TRUcf lY.4SHOUT NOT TO SCALE STAKE (TYP) 10 MIL PLAS LINING 14' 14' # 57 WASHED STONE PLACED TO A HEIGHT OF 12"-18" MINIMUM ABOVE TOP OF BOX C1P0 LE (2 PER BALE) SILT FENCE JF MILPLASTIC LINING STRAW BALE METAL STAKE (2 PER BALE) PLYWOOD PAINTED WHITE BLACK LETTERS 6" TALL CONCRETE WASHOUT WOOD POST T / GROUND LEVEL CONSTRUCTION SPECIFICATIONS. 1. CONCRETE WASHOUT SIGN SHALL BE INSTALLED NO FURTHER THAN 25' FROM THE FACILITY AND SHALL BE VISIBLE TO ALL CONSTRUCTION TRAFFIC. 2. POLYETHYLENE SHEETING SHALL BE 10 MILS FREE OF HOLES, TEARS, OR LEAKS MAINTENANCE.• FACILITY SHALL NOT BE FILLED MORE THAN 12" FROM THE TOP BEFORE DISPOSING OF CONCRETE. CONCRETE SHALL BE DISPOSED OF IN THE SAME MANNER AS OTHER NON-HAZORDOUS MATERIALS FROM THE SITE OR MAY BE BROKEN UP AND USED AS FILL IN NON-STRUCTURAL AREAS. ARC Al IFR INLET P/�OTECT/ON NOT TO SCALE E%IBTING P•� EMBANKMENT �x sQ` Q•M�sl SPILLWAY WIDTH PER SCHEDULE I NOTES: / BASIN WIDTH 1' 1 2' MIN R = 0.75 WIDTH OF SPILLWAY 1. ALL MATERIAL TO MEET CLASS I RIP RAP G� MANUFACTURES SPECIFICATIONS FLOV � �� SIDES OF SPILLWAY; 2 FILTER MEDIA FILL TO MEET 2 MIN. Exlsnxc CULVERT APPLICATION REQUIREMENTS EXCESS SOCK MATERIAL 3. COMPOST MATERIAL TO BE TO BE DRAWN IN AND DISPERSED ON SITE, AS TIED OFF TO 2x2 WOODEN DETERMINED BY ENGINEER. STAKE. (TYPICAL) CLASS I RIP RAP (SEE PLANS FOR DIMENSIONS) SECURE SOCK TO GRATE �.. FILTER SOCK W/RUBBER TIE DOWNS CATCH BASIN CURBSIDE SECTION FIVA68 SOCA INLET PROTECT/ON (INSTALL ONCE CURB OR SIDEWALK IS POURED) NOT TO SCALE CONSTRUCTION SPECIFICATIONS: 1. Inlet protection shall be laced at locations indicated on plans as directed b the Engineer. Inlet protection should p p p Y g be installed in a pattern that allows complete protection of the inlet area. 2. Installation of curb Inlet protection will ensure a minimal overly of at least 1 ft on either side of the opening p p p g being protected. The Inlet protection will be anchored to the soil behind the curb using staples, stakes or other devices capable of holding the Inlet protection in place. 3. Standard Inlet protection for curb inlet protection and curb sediment containment will use 8 in diameter Inlet protection, and drain inlets on soil will use 12 in or 18 in diameter Inlet protection. In severe flow situations, larger Inlet protection maybe specified by the Engineer. During curb installation, Inlet protection shall be compacted to be slightly shorter than curb height. 4. If Inlet protection becomes clogged with debris and sediment, they shall be maintained so as to assure proper drainage and water flow into the storm drain. In severe storm events, overflow ofthe Inlet protection may be acceptable in order to keep the area from flooding. 5. Curb and drain Inlet protection shall be positioned so as to provide apermeable physical barrier to the drain itself, allowing sediment to collect on the outside of the Inlet protection. 6. For drains and inlets that have only curb cuts, without street grates, a spacer is required in order to keep the Inlet protection away from the drain opening. This spacer should be a hog wire screen bent to overlap the grate opening and keep the sock from falling into the opening. Use at least one spacer for every 4 ft of curb drain opening. The wire grid also prevents other floatable waste from passing over the Inlet protection. 7. Stakes shall be installed through the middle of the drain Inlet protection on 5 ft centers, using 2 in x 2 in x 3 ft wood stakes. 8. Staking depth for sand and silt loam soils shall be 12 in and 8 in for clay soils. MAINTENANCE: 1. The Contractor shall maintain the Inlet protection in a functional condition at all times and it shall be routinely inspected. 2. If the Inlet protection has been damaged, it shall be repaired, or replaced if beyond repair. 3. The Contractor shall remove sediment at the base of the upslope side of the Inlet protection when accumulation has reached 1/2 of the effective height of the Inlet protection, or as directed by the Engineer. Alternatively, for drain Inlet protection, anew Sock maybe placed on top of the original increasing the sediment storage capacity without soil disturbance. 4. Inlet protection shall be maintained until disturbed area above or around the device has been permanently stabilized and construction activity has ceased. 5. Regular maintenance includes lifting the Inlet protection and cleaning around and under them as sediment collects. 6. The filter mediawill be removed from paved areas or dispersed on site soil or behind curb once disturbed area has been permanently stabilized, construction activity has ceased, oras determined by the Engineer. 11%AO WA,FCL4#1/ ORA!/EL /NLETPROTECT/ON NOT TO SCALE (CONVERT TO FILTER SOCK ONCE CURB OR SIDEWALK IS POURED) STANDARD METAL POSTS 2'-0" IN GROUND GALVANIZED HARDWARE WIRE EXTENDS TO TOP OF BOX MAINTENANCE. INSPECT THE BARRIER AFTER EACH RA/NAND MAKE REPAIRS AS NEEDED. REMOVE 0 SEDIMENT AS NECESSRY TO PROVIDEADEQUATE STORAGE VOLUME FOR SUBSEQUENT o RAINS. WHEN THE CONTRIBUTING DRAINAGE AREA HAS BEENADEQUATELY STABILIZED, REMOVEALL MATERIALS AND ANY UNSTABLE SOIL, AND EITHER SALVAGE OR DISPOSE 8 p OF IT PROPERLY. BRING THE DISTURBED AREA TO PROPER GRADE, THEN SMOOTH (meq AND COMPACT IT APPROPRIATELY STABILIZEALL BAREAREAS AROUND THE INLET. 9l o CONCRETE TRUcf lY.4SHOUT NOT TO SCALE STAKE (TYP) 10 MIL PLAS LINING 14' 14' # 57 WASHED STONE PLACED TO A HEIGHT OF 12"-18" MINIMUM ABOVE TOP OF BOX C1P0 LE (2 PER BALE) SILT FENCE JF MILPLASTIC LINING STRAW BALE METAL STAKE (2 PER BALE) PLYWOOD PAINTED WHITE BLACK LETTERS 6" TALL CONCRETE WASHOUT WOOD POST T / GROUND LEVEL CONSTRUCTION SPECIFICATIONS. 1. CONCRETE WASHOUT SIGN SHALL BE INSTALLED NO FURTHER THAN 25' FROM THE FACILITY AND SHALL BE VISIBLE TO ALL CONSTRUCTION TRAFFIC. 2. POLYETHYLENE SHEETING SHALL BE 10 MILS FREE OF HOLES, TEARS, OR LEAKS MAINTENANCE.• FACILITY SHALL NOT BE FILLED MORE THAN 12" FROM THE TOP BEFORE DISPOSING OF CONCRETE. CONCRETE SHALL BE DISPOSED OF IN THE SAME MANNER AS OTHER NON-HAZORDOUS MATERIALS FROM THE SITE OR MAY BE BROKEN UP AND USED AS FILL IN NON-STRUCTURAL AREAS. ARC Al IFR INLET P/�OTECT/ON NOT TO SCALE E%IBTING P•� EMBANKMENT �x 1 8' MIN SECTION THRU SPILLWAY ' MIN. MAINTENANCE.• INSPECT ROCK PIPE INLET PROTECTION A T LEAST WEEKL Y AND AFTER EACH SIGNIFICANT RAINFALL EVENT (/2 INCH OR GREATER. REMOVE SEDIMENT AND RESTORE THE SEDIMENT STORAGE AREA TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGN DEPTH OF THE TRAP. PLACE THE SEDIMENT THAT IS REMOVED IN THE DESIGNATED DISPOSAL AREA AND REPLACE THE CONTAMINATED PART OF THE GRAVEL FACING. CHECK THE STRUCTURE FOR DAMAGE. ANY RIP RAP DISCPLACED FROM THE STONE HORSESHOE MUST BE REPLACED IMMEDIATELY. AFTER ALL TEH SEDIMENT -PRODUCING AREAS HAVE BEEN PERMANENTLY STABILIZED, REMOVE THE STRUCTURE AND ALL THE UNSTABLE SEDIMENT. SMOOTH THE AREA TO BLEND WITH THE ADJOINING AREAS AND PROVIDE PERMANENT GROUND COVER (SURFACE STABILIZATION). Behold, a virgin shall be with child, and shall bring forth a son, and they shall call his name Emmanuel, which being interpreted is, God with us. Matthew 1:23 flewg?te,riig►Bag NOT TO SCALE W W W W W W W W W PIWF W W W W W W W W W W W W W W W W W W sQ` Q•M�sl SPILLWAY WIDTH PER SCHEDULE W W W W Y W W W W` W W W W I / W W W ORAS NOTED ON PLANS. BASIN WIDTH 1' 1 2' MIN R = 0.75 WIDTH OF SPILLWAY CLASS I RIP RAP G� ;,J,U_ FLOV � �� SIDES OF SPILLWAY; y\a 2 MIN. Exlsnxc CULVERT 0P 1 FLOW- 1 (MAX) - 1� - EARTHEN BERM - W W W W W W W W W SEDIMENT STORAGE AREA CLASS I RIP RAP (SEE PLANS FOR DIMENSIONS) - I _ . W W W W BERM MAY BE EITHER HORSESHOE OR W W W W RECTANGULAR. FOR RECTANGLE BERM - 11 - -I I 1=1I I 1=1 11 111 11 WATER SPILLWAY MAY BE BUILT BETWEEN THE TWO SIDE BERMS. SPILLWAY 1 WIDTH 0 SIDE BERMS 1 8' MIN SECTION THRU SPILLWAY ' MIN. MAINTENANCE.• INSPECT ROCK PIPE INLET PROTECTION A T LEAST WEEKL Y AND AFTER EACH SIGNIFICANT RAINFALL EVENT (/2 INCH OR GREATER. REMOVE SEDIMENT AND RESTORE THE SEDIMENT STORAGE AREA TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGN DEPTH OF THE TRAP. PLACE THE SEDIMENT THAT IS REMOVED IN THE DESIGNATED DISPOSAL AREA AND REPLACE THE CONTAMINATED PART OF THE GRAVEL FACING. CHECK THE STRUCTURE FOR DAMAGE. ANY RIP RAP DISCPLACED FROM THE STONE HORSESHOE MUST BE REPLACED IMMEDIATELY. AFTER ALL TEH SEDIMENT -PRODUCING AREAS HAVE BEEN PERMANENTLY STABILIZED, REMOVE THE STRUCTURE AND ALL THE UNSTABLE SEDIMENT. SMOOTH THE AREA TO BLEND WITH THE ADJOINING AREAS AND PROVIDE PERMANENT GROUND COVER (SURFACE STABILIZATION). Behold, a virgin shall be with child, and shall bring forth a son, and they shall call his name Emmanuel, which being interpreted is, God with us. Matthew 1:23 flewg?te,riig►Bag NOT TO SCALE W W W W W W W W W PIWF W W W W W W W W W W W W W W W W W W W W W W W/ W SPILLWAY WIDTH PER SCHEDULE W W W W Y W W W W` W W W W I / W W W ORAS NOTED ON PLANS. 1' 1 2' MIN R = 0.75 WIDTH OF SPILLWAY MIN. (IF RECTANGLE THEN 0.5 SPILLWAY WIDTH) CARRY RIP -RAP UP ;,J,U_ PER SCHEDULE OR AS NOTED ON SIDES OF SPILLWAY; it yr 1 1 PLANS, BUT NOT LESS THAN 1.5' NCSA #5 STONE W W W 1 (MAX) - N FLOW 1 cV - F�FF - W W W W W W W W W CLASS I RIP RAP 1 8' MIN SECTION THRU SPILLWAY ' MIN. MAINTENANCE.• INSPECT ROCK PIPE INLET PROTECTION A T LEAST WEEKL Y AND AFTER EACH SIGNIFICANT RAINFALL EVENT (/2 INCH OR GREATER. REMOVE SEDIMENT AND RESTORE THE SEDIMENT STORAGE AREA TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGN DEPTH OF THE TRAP. PLACE THE SEDIMENT THAT IS REMOVED IN THE DESIGNATED DISPOSAL AREA AND REPLACE THE CONTAMINATED PART OF THE GRAVEL FACING. CHECK THE STRUCTURE FOR DAMAGE. ANY RIP RAP DISCPLACED FROM THE STONE HORSESHOE MUST BE REPLACED IMMEDIATELY. AFTER ALL TEH SEDIMENT -PRODUCING AREAS HAVE BEEN PERMANENTLY STABILIZED, REMOVE THE STRUCTURE AND ALL THE UNSTABLE SEDIMENT. SMOOTH THE AREA TO BLEND WITH THE ADJOINING AREAS AND PROVIDE PERMANENT GROUND COVER (SURFACE STABILIZATION). Behold, a virgin shall be with child, and shall bring forth a son, and they shall call his name Emmanuel, which being interpreted is, God with us. Matthew 1:23 flewg?te,riig►Bag NOT TO SCALE W W W W W W W W W PIWF W W W W W W W W W W W W W W W W W W W W W W W/ W W W/W W W W W W Y W W W W` W W W W I / W W W •L/ W INSERT DISCHARGE W W W -- HOSE 5' INTO BAG / - ____-____-D- J1 W W W W "AT WIG BAG W W W W W W W W W sucnox xosE W W W W W W W W W W W W W - I _ . W W W W W W W W W W W W W W W W W W •L� W W W W W W W W W W - 11 - -I I 1=1I I 1=1 11 111 11 WATER I i ii_ W W W W WRAP ROPE 6 TIMES nstallation and Use: 1. Place Dewatering Bag on the ground or on a trailer over a relatively level, stabilized area. 2. Insert discharge pipe a minimum of 5ft. inside dewatering bag and secure with a rope wrapped 6 times around the snout over a 6 inch width of the back 3. -F�eplace Dewatering Bag when half full of sediment or when the sediment has reduced the flow rate of the pump discharge to an impractical amount. Maintenance and Disposal: 1. Remove and dispose of accumulated sediment away from waterways or environmentally sensitive areas. Slit open Sediment Bag and remove accumulated sediment. Dispose of bag at an appropriate recycling or solid waste facility. OR; as directed by engineer or inspector. P/1 PA OUTLETPROTECT/ON NOT TO SCALE �La� n0ER BLANKET OR (MIRAFI 140N) SECTIONAA PIPE OUTLET TO FLAT AREA - NO WELL-DEFINED CHANNEL 5 FILTER BLANKET OR (M/RAFI 140N) SECTIONAA PIPE OUTLET TO WELL-DEFINED CHANNEL GENERAL NOTES• t Lo = THE LENGTH OF THE RTP RAP APRON. 2. d = 1.5 TIMES THE MAXIMUM STONE DIAM£7ER BUT NOT LESS THAN 6' J. INA N£LL-DEFINED CHANNEL EXTEND THE APRON UP THE CHANNEL BANKS TO AN EZEVA770M OF 6' ABOVE THE MAXIMUM TAILWAMR DEPTH OR TO THE TOP OF THE BANK, NHICHEVER IS LESS 4. A RL7FR BLANKET OR RL7FR FABRIC SHOULD BE INSTALLED BETWEEN 7H£ RIPRAP AND SOIL FOUNDAT70N. CONSTRUCTION SPECIRCAAONS- t ENSURE THAT THE SUBWAD£ FOR THE RL TER AND RIPRAP FOLLONS THE REQUIRED LINES AND GRADES SHOWN /N THE PLAN. COMPACT ANY RU REQUIRED IN THE SUBGRAD£ 70 THE DENSITY OF THE SURROUNDING UNDISTURBED MATER/AL. LOW AREAS /N 7H£ SUBGRAD£ ON UNDISTURBED SOIL MAY ALSO BE FILLED BY INCREASING THE RIPRAP THICKNESS 2. THE RIPRAP AND GRAVEL FILTER MUST CONFORM TO THE SPECIRED GRADING LIMITS SHOWN ON THE PLANS J. RL TER CLOTH, WHEN USED, MUST MEET DESIGN REQUIREMENTS AND BE PROPERLY PROTECTED FROM PUNCHING OR TEARING DURING INSTALLATION( REPAIR ANY DAMAGE BY REMOVING THE RIPRAP AND PLACING ANOTHER PIECE OF FILTER CL07H OVER THE DAMAGED AREA. ALL CONNECTING JOINTS SHOULD OVERLAP SO THE TOP LAYER IS ABOVE THE DOWSTR£AM LAYER A MIN/MUM OF 1 FOOT. lF 7H£ DAMAGE IS EXTENSIVE, REPLACE THE ENTIRE FILTER CLO7H. 4. RIPRAP MAY BE PLACED BY EQUIPMENT, BUT TAKE CARE TO AV IYD DAMAGING THE FILTER. 5. THE MIN/MUM THICKNESS OF THE RIPRAP SHOULD BE 1.5 TIMES THE MAX/MUM S70NE DIAMETER. 6. RIPRAP MAY BE R£LD S70Nf OR ROUGH QUARRY STONE. IT -WOULD BE HARD, ANGULAR, HIGHLY WEA7H£R-R£3/STENT AND HELL GRADED. 7. CONSTRUCT 7H£ APRON ON ZERO GRADE NTH NO OVERFILL AT THE END. MAKE THE TOP OF 7H£ RIPRAP AT THE DOWNSTREAM END LEVEL NTH THE RECEIVING AREA OR 3L19171Y BELOW IT. B. ENSURE THAT THE APRON IS PROPERLY ALIGNED WITH THE RECEIVING STREAM AND PREFERABLY STRAIGHT THROUGHOUT I7S LENGTH. IF A CURVE IS NEEDED TO ETT SITE CONDITIONS, PLACE lT IN THE UPPER SECTION OF THE APROM 9. IMMEDIATELY AFTER CONSTRUCTION, STABILIZE ALL DISTURBED AREAS WITH VEGETATION. MAINTENANCE INSPECT RIPRAP OUTLET STRUCTURES WEEKLY AND AFTER SIGNIFICANT (1/2 INCH OR GR£A7ER) RAINFALL EVENTS TO SEE IF ANY EROSION AROUND OR BELOW THE RIPRAP HAS TAKEN PLACE, OR /F STONES HA V£ BEEN DISLODGED. /MMED/A TEL Y MAKE ALL NEEDED REPAIRS TO PREVENT FURTHER DAMAGE. TE/19POR.4RY0//ERS/ON NOW EXCELS/ORA.4TT/NO NOT TO SCALE COMPACTED SOIL 6' TYP. I CONSTRUCTION SPECIFICA ]IONS.• 1 REMOVE AND PROPERLY DISPOSE OF ALL TREES, BRUSH, STUMPS, AND OTHER OBJECTIONABLE MATERIAL. 2. ENSURE THAT THE MINIMUM CONSTRUCTED CROSS SECTION MEETS ALL DESIGN REQUIREMENTS 3. ENSURE THAT THE TOP OF THE DIKE IS NOT LOWER AT ANY POINT THAN THE DESIGN ELEVA77ON PLUS THE SPECIFIED SETTLEMENT. 4. PROVIDE SUFFICIENT ROOM AROUND DIVERSIONS TO PERMIT MACHINE REGRADING AND CLEANOUT. 5. VEGETA 7F THE RIDGE IMMEDIATELY AF7FR CONSTRUC770N, UNLESS IT KL REMAIN IN PLACE LESS THAN 30 WORKING DAYS MAINTENANCE INSPECT TEMPORARY DIVERSIONS ONCE A WEEK AND AF7FR EVERY RAINFALL. /MMEDIA TEL Y REMOVE SEDIMENT FROM THE FLOW AREA AND REPAIR THE DIVERSION RIDGE. CAREFULL Y CHECK OUTLETS AND MAKE 77YEL Y REPAIRS AS NEEDED. WHEN THE AREA PROTECTED IS PERMANENTLY STABILIZED, REMOVE THE RIDGE AND THE CHANNEL TO BLEND WITH THE NA7URAL GROUND LEVEL AND APPROPRIATELY STABILIZE IT. • 00 (0 o am �00 xl O LOrn GO O N In (V w Z O w L O U d Z E w w Z 0 Z Z w Y U O WF- w 3::w WU) Z Z c0 O 00 Z N =U <z Z ~W U) J Ww= 000 Z BLN=C-1874 o' QZ f-ssR, 0,1;9. �L9 < . SEAL 19843 '. e, OHAEL �IIQI 111/� 2/111// 19 AQUA SEWER DETAILS REVISIONS FILE NO. 2018-033 HORZ. SCALE: AS NOTED VERT. SCALE: NONE D-01 SILTFENCEOUTLET NOT TO SCALE 12" OF #57 ROPE FOR FLOW SKIMMER WASHED ST STONE SILT FENCE 1' FREEBOARD MINIMUM BURY 6" AND 1'-8" MIN. SEE PLAN S<OpFSTONE ..y CLASS B EROSION CONTROL FLOW OVERLAP NETTING t<2. MINIVUM OVERLAP 18" Z W AND STAPLING EVERY ,OE 1 FT 2' MIN. FILTER SILT FENCE i iSILT FENCE FABRIC p .INE W W WU) CROSS SECTION TOP VIEW HARDWARE CLOTH FRONT CONSTRUCTION SPECS.• 1. CLEAR & GRUB THE AREA AROUND THE SILT FENCE OUTLET AND PROPERLY DISPOSE OF DEBRIS. 2. PLACE GRAVEL TO THE SPECIFIC GRADE AS SHO WN PER THE DETAIL. J. PROPERLY OVERLAP STONE BEYOND EDGES OF SIL T FENCE OPENING. MAIN TENANCE. • INSPECT OUTLETS WEEKLY AND AFTER EACH RAIN EVENT. IMMEDIA TEL Y REMOVE SEDIMENT FROM THE FL 0 W AREA AND REPAIR AS NEEDED. CAREFULLY CHECK OUTLETS FOR EROSION AND REPAIR IMMEDIA TEL Y. ENSURE THERE IS NO SCOURING APPARENT DOWNSTREAM OF OUTLET. IMMEDIA TEL Y STABILIZE ANY AREAS THA T NEED REPAIR. EXCEUSIORAATFIN00 NOT TO SCALE GENERAL NOTES: 1. Apply seed, and tack with rs or crs liquid emulsified asphalt at a rate equal to 10 gal. per 1000 s.f. Cover w/excelsior matting. 2. Staple every 24" along perimeter edges and overlaps. Staple every J6" to 48" randomly to secure netting. J. Roll out netting in the direction of water flow. Do not stretch. ROOF CHEC/r 0.4N NOT TO SCALE NIATI "D ,\L GROUND CROSS SECTION TEMP. STONE DITCH CHECK STRUCTURAL STONE/ CLASS 'B' B AC SLOPE ISOMETRIC VIEW BASE OF DITCH NIATl GROUND 12" CROSS SECTION TRAPEZOIDAL DITCH SEDIMENT 12 MIN. TRAP FLOW \L TYPE "B" 4'-6" SILT BASIN L ------ 12" THICK SEDIMENT CONTROL STONE ELEVATION VIEW CONSTRUCTION SPECIFICATIONS: 1. Place stone to the lines and dimensions shown in the plans on a filter fabric foundation. 2. Keep the center stone section at least 9 inches below natural ground level where the dam abuts the channel banks. 3. Extend stone at least 1.5 ft. beyond the ditch banks to keep overflow water from undercutting the dam as it re-enters the channel. 4. Set spacing between dams to assure that the elevation at the top of the lower dam is the some as the toe elevation of the upper dam. 5. Protect the channel downstream from the lowest check dam, considering that water will flow over and around the dam. 6. Make sure that the channel reach above the most upstream dam is stable. 7. Ensure that channel appurtenances, such as culvert entrances below check dams, are not subject to damage or blockage from displaced stones. �••j�o�ei oti�oi`�oi ��oi�"'�..;.!�`�oi�.�ioiooi,•i�e�ei�oi�oi�.�ioi�ei,.;���i�oi,.��oi�ei�.�ioi�oi�.�ioi�ei�.�ioi � COMPACTED FILL BACKFILL MIN. 8" FILTER FABRIC METAL POST FILTER FABRIC THICK LAYER OF 11 GRAVEL. EXTENSION OF FABRIC 14" AND WIRE INTO TRENCH -I� �I,���r,.,�I- I-�� _ ���7����� � _III-�i�_II _, `f•:• w :•'. ii iii ii� 00 �•• RE 11- 1 1 2 oR �Di I I Z V- TRENCH) I I 1� 4 I CONSTRUCTION SPECIFICATIONS. - 1. CONSTRUCT THE SEDIMENT BARRIER OF STANDARD OR EXTRA STRENGTH SYNTHETIC FILTER FABRICS. 2. ENSURE THAT THE HEIGHT OF THE SEDIMENT FENCE DOES NOT EXCEED 24 INCHES ABOVE GROUND SURFACE. (HIGHER FENCES MAY IMPOUND VOLUMES OF WATER SUFFICIENT TO CAUSE FAILURE OF THE STRUCTURE). J. CONSTRUCT THE FILTER FABRIC FROM A CONTINUOUS ROLL CUT TO THE LENGTH OF THE BARRIER TO AVOID JOINTS WHEN JOINTS ARE NECESSARY, SECURELY FASTEN THE FILTER CLOTH ONLY AT A SUPPORT POST WITH 4 FEET MINIMUM OVERLAP TO THE NEXT POST. 4. SUPPORT STANDARD FILTER FABRIC BY WIRE MESH FASTENED SECURELY TO THE UPSLOPE SIDE OF THE POSTS EXTEND THE WIRE MESH SUPPORT TO THE BOTTOM OF THE TRENCH. FASTEN THE WIRE REINFORCEMENT, THEN FABRIC ON THE UPSLOPE SIDE OF THE FENCE POST. WIRE OR PLASTIC ZIP TIES SHOULD HAVE MINIMUM 50 POUND TENSILE STRENGTH. 5. WHEN A WIRE MESH SUPPORT FENCE IS USED, SPACE POSTS A MAXIMUM OF 8 FEET APART. SUPPORT POSTS SHOULD BE DRIVEN SECURELY INTO THE GROUND A MINIMUM OF 24 INCHES 6. EXTRA STRENGTH FILTER FABRIC WITH 6 FEET POST SPACING DOES NOT REQUIRE WIRE MESH SUPPORT FENCE. SECURELY FASTEN THE FILTER FABRIC DIRECTLY TO POSTS WIRE OR PLASTIC ZIP TIES SHOULD HAVE MINIMUM 50 POUND TENSILE STRENGTH. 7. EXCAVATE A TRENCH APPROXIMA TEL Y 4 INCHES WIDE AND 8 INCHES DEEP ALONG THE PROPOSED LINE OF POSTS AND UPSLOPE FROM THE BARRIER. 8. PLACE 12 INCHES OF THE FABRIC ALONG THE BOTTOM AND SIDE OF THE TRENCH. 9. BACKFILL THE TRENCH WITH SOIL PLACED OVER THE FILTER FABRIC AND COMPACT. THOROUGH COMPACTION OF THE BACKFILL IS CRITICAL TO SILT FENCE PERFORMANCE. 10. DO NOT ATTACH FILTER FABRIC TO EXISTING TREES. MAINTENANCE. - INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. CONSTRUCT/ON ENTRANCE NOT TO SCALE CONSTRUCTION SPECIFICATIONS. - 1. CLEAR THE ENTRANCE AND EXIT AREA OF ALL VEGETATION, ROOTS, AND OTHER OBJECTIONABLE MATERIAL AND PROPERLY GRADE IT 2. PLACE THE GRAVEL TO THE SPECIFIC GRADE AND DIMENSIONS SHOWN ON THE PLANS AND SMOOTH IT. J. PROVIDE DRAINAGE TO CARRY WATER TO A SEDIMENT TRAP OR OTHER SUITABLE OUTLET. 4. USE GEOTEXTILE FABRICS BECAUSE THEY IMPROVE STABILITY OF THE FOUNDATION IN LOCATIONS SUBJECT TO SEEPAGE OR HIGH WATER TABLE. MAINTENANCE. - MAINTAIN THE GRAVEL PAD IN A CONDITION TO PREVENT MUD OR SEDIMENT FROM LEAVING THE CONSTRUCTION SITE. THIS MAY REQUIRE PERIODIC TOPDRESSING WITH 2 -INCH STONE. AFTER EACH RAINFALL, INSPECT ANY STRUCTURE USED TO TRAP SEDIMENT AND CLEAN IT OUT AS NECESSARY. IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS SPILLED, WASHED, OR TRACKED ONTO PUBLIC ROADWAYS WOODEN STAKE WITH WATTLE ANCHORED TO THE TOP FILTER FABRIC I OR DITCH LINER NOTES: 1. WATTLES SHALL BE FILLED WITH STRAW OR OTHER APPROVED MATERIAL 2. SPACING FOR WATTLES SHALL BE DETERMINED BY THE SITE ENGINEER. 3. WATTLES MAY BE USED FOR PROTECTION OF CATCH BASINS AND DROP INLETS WITH APPROVAL BY THE 12" DIAMETER STRAW FILLED WATTLE ENGINEER. WOODEN STAKE FASTENED TO WOODEN STAKE BY NAIL OR STAPLE FILTER FABRIC DITCHLINE OR DITCH LINER FLOW / 12" DIAMETER STRAW FILLED WATTLE I- DITCHLINE PROFILE VIEW MAINTENANCE.- NOT TO SCALE Inspect check dams and channels for damage after each runoff event. Anticipate submergence and deposition above the check dam and erosion from high flows around the edges of the dam. Correct all damage immediately. if significant erosion occurs between dams, install a protective rip rap liner in that portion of the channel. Remove sediment accumulated behind the dams as needed to prevent damage to channel vegetation, allow the channel to drain throughout the stone check dam, and prevent large flows from carrying sediment over the dam. Add stones to dams as needed to maintain design height and cross section. 8" FABRIC STAPLE 18" 18" SAr//l9A9ER SED%9E/VTBAS/N NOT 70 SCALE ARM ASSEMBLY "C" ENCLOSURE �i :WATER ENTRY UNIT PE/�SPECT Y,Fy/E`Y NOT TO SCALE PVC END CAP ROPE FOR PVC VENT PVC ELBOW SKIMMER PIPE SCHEDULE 40 PVC PIPE RETRIEVAL WATER SURFACE SCHEDULE 40 PVC PIPE PVC END CAP PVC PIPE ORIFICE PLATE PVC TEE 1/2' HOLES IN FLEXIBLE HOSE PVC TEE UNDERSIDE 4'X4' #57 C0000CII STONE PAD END VIEW FRONT VIEW BOTTOM SURFACE NOT TO SCALE NOT TO SCALE INFLOW STRUCTL NOT TO SCALE INFLOW BAFFLES STRUCTURE DEWATERING ZONE FILTER FABRIC _ SEDIMENT STORAGE ZONE CROSS-SECTION VIEW NOT TO SCALE ROPE FOR SKIMMER RETRIEVAL EMERGENCY SPILLWAY ROPE FOR FLOW SKIMMER NONE TURVDOW\ VETTING 1' FREEBOARD MINIMUM BURY 6" AND STAPLE EVERY 1 FT, JUST 04 BELOW ANCHOR SLOT. ..y EMERGENCY FLOW OVERLAP NETTING MINIVUM OVERLAP 18" Z W AND STAPLING EVERY ,OE 1 FT 1 FT THROUGH BOTH LAYERS. TYPICAL STAPLE p USE #6 GAUGE WIRE GENERAL NOTES: 1. Apply seed, and tack with rs or crs liquid emulsified asphalt at a rate equal to 10 gal. per 1000 s.f. Cover w/excelsior matting. 2. Staple every 24" along perimeter edges and overlaps. Staple every J6" to 48" randomly to secure netting. J. Roll out netting in the direction of water flow. Do not stretch. ROOF CHEC/r 0.4N NOT TO SCALE NIATI "D ,\L GROUND CROSS SECTION TEMP. STONE DITCH CHECK STRUCTURAL STONE/ CLASS 'B' B AC SLOPE ISOMETRIC VIEW BASE OF DITCH NIATl GROUND 12" CROSS SECTION TRAPEZOIDAL DITCH SEDIMENT 12 MIN. TRAP FLOW \L TYPE "B" 4'-6" SILT BASIN L ------ 12" THICK SEDIMENT CONTROL STONE ELEVATION VIEW CONSTRUCTION SPECIFICATIONS: 1. Place stone to the lines and dimensions shown in the plans on a filter fabric foundation. 2. Keep the center stone section at least 9 inches below natural ground level where the dam abuts the channel banks. 3. Extend stone at least 1.5 ft. beyond the ditch banks to keep overflow water from undercutting the dam as it re-enters the channel. 4. Set spacing between dams to assure that the elevation at the top of the lower dam is the some as the toe elevation of the upper dam. 5. Protect the channel downstream from the lowest check dam, considering that water will flow over and around the dam. 6. Make sure that the channel reach above the most upstream dam is stable. 7. Ensure that channel appurtenances, such as culvert entrances below check dams, are not subject to damage or blockage from displaced stones. �••j�o�ei oti�oi`�oi ��oi�"'�..;.!�`�oi�.�ioiooi,•i�e�ei�oi�oi�.�ioi�ei,.;���i�oi,.��oi�ei�.�ioi�oi�.�ioi�ei�.�ioi � COMPACTED FILL BACKFILL MIN. 8" FILTER FABRIC METAL POST FILTER FABRIC THICK LAYER OF 11 GRAVEL. EXTENSION OF FABRIC 14" AND WIRE INTO TRENCH -I� �I,���r,.,�I- I-�� _ ���7����� � _III-�i�_II _, `f•:• w :•'. ii iii ii� 00 �•• RE 11- 1 1 2 oR �Di I I Z V- TRENCH) I I 1� 4 I CONSTRUCTION SPECIFICATIONS. - 1. CONSTRUCT THE SEDIMENT BARRIER OF STANDARD OR EXTRA STRENGTH SYNTHETIC FILTER FABRICS. 2. ENSURE THAT THE HEIGHT OF THE SEDIMENT FENCE DOES NOT EXCEED 24 INCHES ABOVE GROUND SURFACE. (HIGHER FENCES MAY IMPOUND VOLUMES OF WATER SUFFICIENT TO CAUSE FAILURE OF THE STRUCTURE). J. CONSTRUCT THE FILTER FABRIC FROM A CONTINUOUS ROLL CUT TO THE LENGTH OF THE BARRIER TO AVOID JOINTS WHEN JOINTS ARE NECESSARY, SECURELY FASTEN THE FILTER CLOTH ONLY AT A SUPPORT POST WITH 4 FEET MINIMUM OVERLAP TO THE NEXT POST. 4. SUPPORT STANDARD FILTER FABRIC BY WIRE MESH FASTENED SECURELY TO THE UPSLOPE SIDE OF THE POSTS EXTEND THE WIRE MESH SUPPORT TO THE BOTTOM OF THE TRENCH. FASTEN THE WIRE REINFORCEMENT, THEN FABRIC ON THE UPSLOPE SIDE OF THE FENCE POST. WIRE OR PLASTIC ZIP TIES SHOULD HAVE MINIMUM 50 POUND TENSILE STRENGTH. 5. WHEN A WIRE MESH SUPPORT FENCE IS USED, SPACE POSTS A MAXIMUM OF 8 FEET APART. SUPPORT POSTS SHOULD BE DRIVEN SECURELY INTO THE GROUND A MINIMUM OF 24 INCHES 6. EXTRA STRENGTH FILTER FABRIC WITH 6 FEET POST SPACING DOES NOT REQUIRE WIRE MESH SUPPORT FENCE. SECURELY FASTEN THE FILTER FABRIC DIRECTLY TO POSTS WIRE OR PLASTIC ZIP TIES SHOULD HAVE MINIMUM 50 POUND TENSILE STRENGTH. 7. EXCAVATE A TRENCH APPROXIMA TEL Y 4 INCHES WIDE AND 8 INCHES DEEP ALONG THE PROPOSED LINE OF POSTS AND UPSLOPE FROM THE BARRIER. 8. PLACE 12 INCHES OF THE FABRIC ALONG THE BOTTOM AND SIDE OF THE TRENCH. 9. BACKFILL THE TRENCH WITH SOIL PLACED OVER THE FILTER FABRIC AND COMPACT. THOROUGH COMPACTION OF THE BACKFILL IS CRITICAL TO SILT FENCE PERFORMANCE. 10. DO NOT ATTACH FILTER FABRIC TO EXISTING TREES. MAINTENANCE. - INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. CONSTRUCT/ON ENTRANCE NOT TO SCALE CONSTRUCTION SPECIFICATIONS. - 1. CLEAR THE ENTRANCE AND EXIT AREA OF ALL VEGETATION, ROOTS, AND OTHER OBJECTIONABLE MATERIAL AND PROPERLY GRADE IT 2. PLACE THE GRAVEL TO THE SPECIFIC GRADE AND DIMENSIONS SHOWN ON THE PLANS AND SMOOTH IT. J. PROVIDE DRAINAGE TO CARRY WATER TO A SEDIMENT TRAP OR OTHER SUITABLE OUTLET. 4. USE GEOTEXTILE FABRICS BECAUSE THEY IMPROVE STABILITY OF THE FOUNDATION IN LOCATIONS SUBJECT TO SEEPAGE OR HIGH WATER TABLE. MAINTENANCE. - MAINTAIN THE GRAVEL PAD IN A CONDITION TO PREVENT MUD OR SEDIMENT FROM LEAVING THE CONSTRUCTION SITE. THIS MAY REQUIRE PERIODIC TOPDRESSING WITH 2 -INCH STONE. AFTER EACH RAINFALL, INSPECT ANY STRUCTURE USED TO TRAP SEDIMENT AND CLEAN IT OUT AS NECESSARY. IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS SPILLED, WASHED, OR TRACKED ONTO PUBLIC ROADWAYS WOODEN STAKE WITH WATTLE ANCHORED TO THE TOP FILTER FABRIC I OR DITCH LINER NOTES: 1. WATTLES SHALL BE FILLED WITH STRAW OR OTHER APPROVED MATERIAL 2. SPACING FOR WATTLES SHALL BE DETERMINED BY THE SITE ENGINEER. 3. WATTLES MAY BE USED FOR PROTECTION OF CATCH BASINS AND DROP INLETS WITH APPROVAL BY THE 12" DIAMETER STRAW FILLED WATTLE ENGINEER. WOODEN STAKE FASTENED TO WOODEN STAKE BY NAIL OR STAPLE FILTER FABRIC DITCHLINE OR DITCH LINER FLOW / 12" DIAMETER STRAW FILLED WATTLE I- DITCHLINE PROFILE VIEW MAINTENANCE.- NOT TO SCALE Inspect check dams and channels for damage after each runoff event. Anticipate submergence and deposition above the check dam and erosion from high flows around the edges of the dam. Correct all damage immediately. if significant erosion occurs between dams, install a protective rip rap liner in that portion of the channel. Remove sediment accumulated behind the dams as needed to prevent damage to channel vegetation, allow the channel to drain throughout the stone check dam, and prevent large flows from carrying sediment over the dam. Add stones to dams as needed to maintain design height and cross section. 8" FABRIC STAPLE 18" 18" SAr//l9A9ER SED%9E/VTBAS/N NOT 70 SCALE ARM ASSEMBLY "C" ENCLOSURE �i :WATER ENTRY UNIT PE/�SPECT Y,Fy/E`Y NOT TO SCALE PVC END CAP ROPE FOR PVC VENT PVC ELBOW SKIMMER PIPE SCHEDULE 40 PVC PIPE RETRIEVAL WATER SURFACE SCHEDULE 40 PVC PIPE PVC END CAP PVC PIPE ORIFICE PLATE PVC TEE 1/2' HOLES IN FLEXIBLE HOSE PVC TEE UNDERSIDE 4'X4' #57 C0000CII STONE PAD END VIEW FRONT VIEW BOTTOM SURFACE NOT TO SCALE NOT TO SCALE INFLOW STRUCTL NOT TO SCALE INFLOW BAFFLES STRUCTURE DEWATERING ZONE FILTER FABRIC _ SEDIMENT STORAGE ZONE CROSS-SECTION VIEW NOT TO SCALE ROPE FOR SKIMMER RETRIEVAL EMERGENCY SPILLWAY CONSNUCRON SPECIFICATIONS• 1. Clear, grub, and strip the area under the embankment of all vegetation and root mat. Remove all surface soil containing high amounts of organic matter and stockpile or dispose of it properly. Haul all objectionable material to the designated disposal area. Place temporary sediment control measures below basin as needed. 2. Ensure that All material for the embankment is free of roots, woody vegetation, organic matter, and other objectionable material. Place the All in lifts not to exceed 9 inches, and machine compact it. Over All the embankment 6 inches to allow for settlement. J. ShGpe the basin to the specified dimensions Prevent the skimming device from settling into the mud by excavating a shallow pit under the skimmer or providing a low support under the skimmer of stone or timber. 4. Place the barrel (t)pically 4 -inch Schedule 40 PI/C pipe) on o firm, smooth foundation of impervious soil. Do not use pervious mdter)GI such os sand, grovel, or crushed stone as backflll around the pipe. Place the fill material Ground the pipe spillway in 4 -inch /dyers and compact it under and Ground the pipe to at least the same density as the adjacent embankment. Care must be taken not to raise the pipe from the firm contact with its foundation when compacting under the pipe haunches. Place a minimum depth of 2 feet of compacted backflll over the pipe spillway before crossing it with construction equipment. In no case should the pipe conduit be installed by cutting a trench through the dam after the embankment is complete. 5. Assemble the skimmer following the manufacturers instructions, or as designed. 6. Lay the assembled skimmer on the bottom of the basin with the flexible joint at the inlet of the barrel pipe. Attach the flexible joint to the barrel pipe and position the skimmer over the excavated pit or support. Be sure to attach a rope to the skimmer and anchor it to the side of the basin. This will be used to pull the skimmer to the side for maintenance. 7. Earthen spillways - Install the spillway in undisturbed soil to the greatest extent possible. the achievement of planned elevations, grade, design width, and entrance and exit channel slopes are critical to the successful operation of the spillway. The spillway should be lined with laminated plastic or impermeable geotextile fabric. The fabric must be wide and long enough to cover the bottom and sides and extend onto the top of the dam for anchoring in o trench. The edges may be secured with 8 -inch staples or pins The fabric must be long enough to extend down the slope and exit onto stable ground the width of the fabric must be one piece, not joined or spliced,• otherwise water can get under the fabric. if the length of the fabric is insufficient for the entire length of the spillway, multiple sections, spanning the complete width, may be used. The upper sections) should overlap the lower section(s) so the water cannot flow under the fabric. Secure the upper edge and sides of the fabric in a trench with staples or pins. 8. Inlets - Discharge water into the basin in a manner to prevent erosion. Use temporary slope drains or diversions with outlet protection to divert sediment -laden water to the upper end of the pool area to improve basin trap efficiency. 9. Erosion control - Construct the structure so that the disturbed area is minimized. Divert surface water away from bare areas. Complete the embankment before the area is cleared. Stabilize the emergency spillway embankment and all other disturbed areas above the crest of the principal spillway immediately after construction. 10. Install porous baffles as specified. 11. After all the sediment -producing areas have been permanently stabilized, remove the structure and all the unstable sediment. Smooth the area to blend with the adjoining areas and stabilize properly. MAINTENANCE- Inspect AINTENANCE.• Ins ect skimmer sediment basins at least week/ and after each significant one-half inch or greater) rainfall event and repair immediately. Remove sediment and restore P y 9 ( 9 ) P y the basin to its original dimensions when sediment accumulates to one-half the height of the first baffle. Pull the skimmer to one side so that the sediment underneath it can be excavated. Excavate the sediment from the entire basin, not just around the skimmer or the first cell. Make sure vegetation growing in the bottom of the basin does not hold down the skimmer. Repair the baffles if they are damaged. Re -anchor the baffles if water is flowing underneath or around them. If the skimmer is clogged with trash and there is water in the basin, usually jerking on the rope will make the skimmer bob up and down and dislodge the debris and restore flow. If this does not work, pull the skimmer over to the side of the basin and remove the debris. Also check the orifice inside the skimmer to see if it is clogged,- if so remove the debris. If the skimmer arm or barrel pipe is clogged, the orifice can be removed and the obstruction cleared with a plumber's snake or by flushing with water. Be sure and replace the orifice before repositioning the skimmer. Check the fabric lined spillway for damage and make any required repairs with fabric that spans the full width of the spillway. Check the embankment, spillways, and outlet for erosion damage, and inspect the embankment for piping and settlement. Make all necessary repairs immediately. Remove all trash and other debris from the skimmer and pool areas. Freezing weather can result in ice forming in the basin. Some special precautions should be taken in the winter to prevent the skimmer from plugging with ice. Maintenance Notes: 1. Do not let any area remained exposed for more than 7 or 14 calendar days according to chart without applying temporary seeding. 2. Maintain all erosion control measures daily and reseed disturbed areas as needed. 3. Inspect all erosion control measures weekly and after each rainfall event. Repair as needed. 4. At the end of each day's storm drainage operation, construct a temporary pipe inlet protection device until the next day's operation continues. Behold, a virgin shall be with child, and shall bring forth a son, and they shall call his name Emmanuel, which being interpreted is, God with us. Matthew 1:23 POROUS BAFFLES N A SEDIuENT BASH sway a PM u sro turns / 'TW T, WWsway WE 10 METOPKW SCE WE siaaw / � as MM aWam surx, SUFM OTM OR SKa CROSS-SECTION OF A POROUS BAFFLE o� POROUS BAFFLE USING SILT FENCE WITH SLITS CUT N EACH ALTERNATING SPACE OF WIRE BACKING FENCE Era rxE,, CONSTRUCTION SPECIFICATIONS: 1. Grade the basin so that the bottom is level front to back and side to side. 2. Install posts or saw horses across the width of the sediment trap (Practice 6.62, Sediment Fence). 3. Steel posts should be driven to a depth of 24 inches, spaced a miximum of 4 feet apart, and installed up the sides of the basin as well. The top of the fabric should be 6 inches higher than the invert of the spillway. Tops of baffles should be 2 inches lower than the top of the berms. 4. Install at least three rows of baffles between the inlet and outlet discharge point. Basins less than 20 feel in length may use 2 baffles. 5. When usingposts, add a support wire or roe across the to of the measure to prevent sagging. P PP P P P 6. Wrap porous material, like jute backed by coir material, over a sawhorse or the top wire. Hammer rebar into the sawhorse legs for anchoring. The fabric should have five to ten percent openings in the weave. Attach fabric to a rope and a support structure with zip ties, wire, or staples. 7 The bottom and sides of the fabric should be anchored in a trench or pinned with 8 -inch erosion control matting staples. 8. Do not splice the fabric, but use a continuous piece across the basin. MAINTENANCE: Inspect baffles at least once a week and after each rainfall. Make any required repairs immediately. Be sure to maintain access to the baffles. Should the fabric of a baffle collapse, tear, decompose, or become ineffective, replace it promptly. Remove sediment deposits when it reaches half full to provide adequate storage volume for the next rain and to reduce pressure on the baffles. Take care to avoid damaging the baffles during cleanout. Sediment depth should never exceed half the designed 99 9 P 9 storage depth. After the contributing drainage area has been properly stabilized, remove all baffle materials and unstable sediment deposits, bring the area to grade, and stabilize it. SKIMMER BASIN DE -COMMISSIONING SEQUENCE: 1. Obtain approval to remove temporary erosion control measures from NCDENR Land Quality Section. 2. Provide Pump and Silt Bag and remove water from skimmer basin. 3. Backfill basin with onsite material. 4. Permanently seed remaining sturbed areas. W Z O ROPE FOR 1 SKIMMER NONE RETRIEVAL 1' FREEBOARD EMBANKMENT Z 04 E 6" MIN. INVERT ELEVATION OF EMERGENCY EMERGENCY SPILLWAY SPILLWAY CONSNUCRON SPECIFICATIONS• 1. Clear, grub, and strip the area under the embankment of all vegetation and root mat. Remove all surface soil containing high amounts of organic matter and stockpile or dispose of it properly. Haul all objectionable material to the designated disposal area. Place temporary sediment control measures below basin as needed. 2. Ensure that All material for the embankment is free of roots, woody vegetation, organic matter, and other objectionable material. Place the All in lifts not to exceed 9 inches, and machine compact it. Over All the embankment 6 inches to allow for settlement. J. ShGpe the basin to the specified dimensions Prevent the skimming device from settling into the mud by excavating a shallow pit under the skimmer or providing a low support under the skimmer of stone or timber. 4. Place the barrel (t)pically 4 -inch Schedule 40 PI/C pipe) on o firm, smooth foundation of impervious soil. Do not use pervious mdter)GI such os sand, grovel, or crushed stone as backflll around the pipe. Place the fill material Ground the pipe spillway in 4 -inch /dyers and compact it under and Ground the pipe to at least the same density as the adjacent embankment. Care must be taken not to raise the pipe from the firm contact with its foundation when compacting under the pipe haunches. Place a minimum depth of 2 feet of compacted backflll over the pipe spillway before crossing it with construction equipment. In no case should the pipe conduit be installed by cutting a trench through the dam after the embankment is complete. 5. Assemble the skimmer following the manufacturers instructions, or as designed. 6. Lay the assembled skimmer on the bottom of the basin with the flexible joint at the inlet of the barrel pipe. Attach the flexible joint to the barrel pipe and position the skimmer over the excavated pit or support. Be sure to attach a rope to the skimmer and anchor it to the side of the basin. This will be used to pull the skimmer to the side for maintenance. 7. Earthen spillways - Install the spillway in undisturbed soil to the greatest extent possible. the achievement of planned elevations, grade, design width, and entrance and exit channel slopes are critical to the successful operation of the spillway. The spillway should be lined with laminated plastic or impermeable geotextile fabric. The fabric must be wide and long enough to cover the bottom and sides and extend onto the top of the dam for anchoring in o trench. The edges may be secured with 8 -inch staples or pins The fabric must be long enough to extend down the slope and exit onto stable ground the width of the fabric must be one piece, not joined or spliced,• otherwise water can get under the fabric. if the length of the fabric is insufficient for the entire length of the spillway, multiple sections, spanning the complete width, may be used. The upper sections) should overlap the lower section(s) so the water cannot flow under the fabric. Secure the upper edge and sides of the fabric in a trench with staples or pins. 8. Inlets - Discharge water into the basin in a manner to prevent erosion. Use temporary slope drains or diversions with outlet protection to divert sediment -laden water to the upper end of the pool area to improve basin trap efficiency. 9. Erosion control - Construct the structure so that the disturbed area is minimized. Divert surface water away from bare areas. Complete the embankment before the area is cleared. Stabilize the emergency spillway embankment and all other disturbed areas above the crest of the principal spillway immediately after construction. 10. Install porous baffles as specified. 11. After all the sediment -producing areas have been permanently stabilized, remove the structure and all the unstable sediment. Smooth the area to blend with the adjoining areas and stabilize properly. MAINTENANCE- Inspect AINTENANCE.• Ins ect skimmer sediment basins at least week/ and after each significant one-half inch or greater) rainfall event and repair immediately. Remove sediment and restore P y 9 ( 9 ) P y the basin to its original dimensions when sediment accumulates to one-half the height of the first baffle. Pull the skimmer to one side so that the sediment underneath it can be excavated. Excavate the sediment from the entire basin, not just around the skimmer or the first cell. Make sure vegetation growing in the bottom of the basin does not hold down the skimmer. Repair the baffles if they are damaged. Re -anchor the baffles if water is flowing underneath or around them. If the skimmer is clogged with trash and there is water in the basin, usually jerking on the rope will make the skimmer bob up and down and dislodge the debris and restore flow. If this does not work, pull the skimmer over to the side of the basin and remove the debris. Also check the orifice inside the skimmer to see if it is clogged,- if so remove the debris. If the skimmer arm or barrel pipe is clogged, the orifice can be removed and the obstruction cleared with a plumber's snake or by flushing with water. Be sure and replace the orifice before repositioning the skimmer. Check the fabric lined spillway for damage and make any required repairs with fabric that spans the full width of the spillway. Check the embankment, spillways, and outlet for erosion damage, and inspect the embankment for piping and settlement. Make all necessary repairs immediately. Remove all trash and other debris from the skimmer and pool areas. Freezing weather can result in ice forming in the basin. Some special precautions should be taken in the winter to prevent the skimmer from plugging with ice. Maintenance Notes: 1. Do not let any area remained exposed for more than 7 or 14 calendar days according to chart without applying temporary seeding. 2. Maintain all erosion control measures daily and reseed disturbed areas as needed. 3. Inspect all erosion control measures weekly and after each rainfall event. Repair as needed. 4. At the end of each day's storm drainage operation, construct a temporary pipe inlet protection device until the next day's operation continues. Behold, a virgin shall be with child, and shall bring forth a son, and they shall call his name Emmanuel, which being interpreted is, God with us. Matthew 1:23 POROUS BAFFLES N A SEDIuENT BASH sway a PM u sro turns / 'TW T, WWsway WE 10 METOPKW SCE WE siaaw / � as MM aWam surx, SUFM OTM OR SKa CROSS-SECTION OF A POROUS BAFFLE o� POROUS BAFFLE USING SILT FENCE WITH SLITS CUT N EACH ALTERNATING SPACE OF WIRE BACKING FENCE Era rxE,, CONSTRUCTION SPECIFICATIONS: 1. Grade the basin so that the bottom is level front to back and side to side. 2. Install posts or saw horses across the width of the sediment trap (Practice 6.62, Sediment Fence). 3. Steel posts should be driven to a depth of 24 inches, spaced a miximum of 4 feet apart, and installed up the sides of the basin as well. The top of the fabric should be 6 inches higher than the invert of the spillway. Tops of baffles should be 2 inches lower than the top of the berms. 4. Install at least three rows of baffles between the inlet and outlet discharge point. Basins less than 20 feel in length may use 2 baffles. 5. When usingposts, add a support wire or roe across the to of the measure to prevent sagging. P PP P P P 6. Wrap porous material, like jute backed by coir material, over a sawhorse or the top wire. Hammer rebar into the sawhorse legs for anchoring. The fabric should have five to ten percent openings in the weave. Attach fabric to a rope and a support structure with zip ties, wire, or staples. 7 The bottom and sides of the fabric should be anchored in a trench or pinned with 8 -inch erosion control matting staples. 8. Do not splice the fabric, but use a continuous piece across the basin. MAINTENANCE: Inspect baffles at least once a week and after each rainfall. Make any required repairs immediately. Be sure to maintain access to the baffles. Should the fabric of a baffle collapse, tear, decompose, or become ineffective, replace it promptly. Remove sediment deposits when it reaches half full to provide adequate storage volume for the next rain and to reduce pressure on the baffles. Take care to avoid damaging the baffles during cleanout. Sediment depth should never exceed half the designed 99 9 P 9 storage depth. After the contributing drainage area has been properly stabilized, remove all baffle materials and unstable sediment deposits, bring the area to grade, and stabilize it. SKIMMER BASIN DE -COMMISSIONING SEQUENCE: 1. Obtain approval to remove temporary erosion control measures from NCDENR Land Quality Section. 2. Provide Pump and Silt Bag and remove water from skimmer basin. 3. Backfill basin with onsite material. 4. Permanently seed remaining sturbed areas. W Z O BLN=C-1874 X� a ' F o,1;9. �L9 4Z . SEAL 19843 791AEL S�OG 4uQc-/ 2/1/19 AQUA SEWER OETA/LS REVISIONS FILE NO. 2018-033 0 1 O NONE U 6 Z E W W Z 0 Z W Z cnY � U O WH- W W WU) Z Z co O LO • co � Z N tI = U Z Z �W J W (n W = ¢' cn z QOo BLN=C-1874 X� a ' F o,1;9. �L9 4Z . SEAL 19843 791AEL S�OG 4uQc-/ 2/1/19 AQUA SEWER OETA/LS REVISIONS FILE NO. 2018-033 HORZ. SCALE: AS NOTED VERT. SCALE: NONE US FOUNDRY MODEL 170-E NCAPSULATION SYSTEM OVER. R/W SEE NOTE #2 (SEE DETAIL) FORD VBH77-15B X 10 If MINIMUM WATER LINE AND FINISHED GRADE YOKE FOR METER SEPARATION RPZ WATER SERVICE FROM WA O SEE NOTE 11 WATER SERVICE I 5" MINIMUM WALL 1 PLAN RINGS (AS REQ'D) WALLS SHALL BE USED OTHER LINE. IF REQUIRED FOR `INSULATED ENCLOSURE 'HOT BOX•, STRUCTURAL STRENGTH) LINK SEAL GASKET \ AS REQ'D / 'H OR EQUAL ENCLOSURE WALL REINFORCEMENT CHANNEL PER ASTM C478 PER SHALL HAVE HAVE A HINGED, LOCKABLE DD 4000 PSI ® 28 DAY J 1SANITARY CONCTETE TYPE II AND MINIMUM 9" CLEARANCE ON EACH GRAVITY - 6" MIN RPZ BACKFLOW PREVENTEREND 1/ A, EACH SIDE OF THE RPZ 11. WHEN THERE IS LESS THAN TWENTY FOUR MAIN OR STORM SEWER FEBCO - RPZ MODEL 825Y GI Y. 2. A MINIMUM HORIZONTAL SEPARATION WATER MAIN WATER MAIN AND STORM SEWER, THE WATER /-FLANGED COUPUNG ADAPTER 5. IF THE NON -CONFORMING LINE IS A GRAVITY (3) FEET OUTSIDE TO OUTSIDE SHAA LL BEMAINTAINED VERTICAL SEPARATION BETWEEN WATER MAINS MASONARY ONE FULL LENGTH OF PIPE SHALL BE CENTERED FORD VBH77-158 X WITH HINGED SUPPORT (TYP) FINISHED GRADE YOKE FOR METER WITH/UD 'TOUCH READ" UD 1-1/2" PVC WATER LINES CARRYING DOUBLE CHECK VAL MAINTAIN THE REQUIRED SEPARATION, IT SHALL BE REPORTED TO AQUA NORTH CAROLINA, DRAIN TO GRAVITY SEWER WHERE THERE IS LESS THAN EIGHTEEN (18) INCHES VERTICAL CLEARANCE INC./ENGINEER. SPECIAL SOLUTIONS MUST BE NATURAL GROUND DAYLIGHT ACCEPTED BY NCDENR PRIOR TO Z 0 L GRAVITY SEWER TO DIP PVC AND IMPLEMENTATION. 6. IF THE OTHER LINE IS A RECLAIMED WATER 11 ANQUE tlE« II=III II I� LINE AND THE ABOVE SEPARATION STANDARDS. PIPES SHALL BE LOCATED SO THAT 8 II�gi -II CONCRETE METER BOX, S� RECLAIMED WATER LINE MATERIAL TO DUCTILE BROOKS, No. 38-H WITH \ IRON. 12• EXTENSION i.• -A5 LINE AND THE ABOVE MINIMUM SEPARATION IS oa BE CONSIDERED ON CASE-BY-CASE BASIS AND BLOCK SUPPORT OR SDR 35 SW PVC 1/4 B�O WATER SERVICE MATERIAL TO DUCTILE IRON. STONE AS NEEDED WATER SERVICE FROM WHENEVER POSSIBLE. LOCATE DOUBLE LATERAL AS IMPLEMENTATION. CONCRETE SADDLES MAY BE NECESSARY AT THE 8. THERE SHALL BE AT LEAST A TEN (10) FOOT \ '• ' `90' BEND CLASS 200 POLYETHELYNE ':.': • .':. '.':.':.'. SERVICE UNE .. """""" ••• • • 90' BEND .'::::::.':: LASS 200 POLYETHEl YNE DUPLEX OUTLET SHALL N� SANITARY SEWER FORCE MAINS WITHOUT SERVICE UNE BE PROVIDED FOR POWER EXCEPTION. FIELD PROBLEMS SHALL BE BYPASS VALVE TO HEAT BOX J X57 WASHED STONE WHEN WHEN BOTH BUILDING SLABS ARE NOT ¢ 1X1 PVC DRAIN SECTION C CONCRETE SLAB. MIN. 6" WIDER THAN BOX <' TO DAYLIGHT RESPONSIBILITY ON ALL SIDES 1 1 /2" and 2" WATER SERVICE W/ RPZ & B F P NOT TO SCALE PROVIDE BRASS RING & PLUG Name Date JOFNSTON COUNTY Department of Public Utilities P.O. Box 226311/Z' Smithfield, NC 27577 WATER STANDARD DETAIL and 2" Meter& Backflow Assembly PAGE M L 1 of 47 Drawn By: Checked By: Approved By: Scale: Rev. Description Date Init. US FOUNDRY MODEL 170-E NCAPSULATION SYSTEM OVER. C.I. FRAME & COVER SEE NOTE #2 (SEE DETAIL) STORM SEWER, & POTABLE WATER MAIN ADJUST TO WATER LINE AND FINISHED GRADE CONICAL MANHOLE TOP W/ GRADE HEAT SHRINK MANHOLE RINGS FINI SEE NOTE 11 SEE NOTE #2 COVER. SEE NOTE #1 5" MINIMUM WALL 1 THICKNESS (THICKER RINGS (AS REQ'D) WALLS SHALL BE USED OTHER LINE. IF REQUIRED FOR A-LOK OR STRUCTURAL STRENGTH) LINK SEAL GASKET \ AS REQ'D I BRICK & MORTAR WALL REINFORCEMENT CHANNEL PER ASTM C478 PER TER MAIMAINTAINED 4000 PSI ® 28 DAY J 1SANITARY CONCTETE TYPE II SHALL BE CONSIDERED ON CASE-BY-CASE BASIS TYPICAL BASE REINFORCEMENT SHALL BE: 8" AASHTO NO. NO. 4 BARS ® 12" O,C, FOR DEPTHS UNDER 6' STONE - COMPAC NO. 4 BARS ® 9" O,C, FOR GREATER DEPTHS 8.5" MINIMI SLAB THICKNESS STRIP JOINT SEALANT AQUA to North Carolina, Inc. RAISED 1-j" LETTERS FLUSHED WITH TOP OF COVER LABELED SANITARY MANHOLE COVER TYPE BJ MANHOLE COVER TYPE J IN USF 170 MANHOLE RING NOTES: 1. ARTERIAL ROADWAYS - USF RING AND COVER SERIES 170-13J. HEAVY DUTY LOAD RATING. COVER WEIGHT 217#, TOTAL WEIGHT 372#. 2. ALL OTHER APPLICATIONS - USF RING AND COVER SERIES 170-J. HEAVY DUTY LOAD RATING. COVER WEIGHT 150#, TOTAL WEIGHT 305#. 3. CITY IDENTIFIER SHALL BE USED FOR CITY OWNED STRUCTURES ONLY. PRIVATE FACILITIES SHALL ONLY BE IDENTIFIED AS TO USE. 4. AQUA NORTH CAROLINA MAY REQUIRE LOCKING MANHOLES AT CERTAIN LOCATIONS. 7 Ka AQUA 23 BE.na MANHOLE FRAME AND COVER DETAILS 05/2012 Aqua North Carolina, Inc. HEAT SHRINK MANHOLE CAST IRON FRAME AND NCAPSULATION SYSTEM OVER. SEE NOTE #1 SEE NOTE #2 WHERE CROSSING WITH POTABLE STORM SEWER, & POTABLE WATER MAIN CONCRETE ADJUSTING WATER LINE AND RINGS (AS REQ'D) CONICAL MANHOLE TOP A HEAT SHRINK MANHOLE WATER LINE AT SUCH AN ELEVATION THAT THE ENCAPSULATION SYSTEM CASTIRON FRAME AND SEE NOTE #2 COVER. SEE NOTE #1 8" CONCRETE ADJUSTING -rI' RINGS (AS REQ'D) SANITARY GRAVITY MAIN OTHER LINE. I AOUA -` BENBW MlE rSANITARY AS REQ'D 4. IF THE MINIMUM ALLOWABLE TEN (10) FOOT Aqua North Carolina, Inc. SANITARY GRAVITY, FORCE MAIN, REUSE MAIN, 9. NO WATER PIPE SHALL PASS THROUGH OR FINISHED GRADE MAINTAIN THE REQUIRED SEPARATION, THE WHERE CROSSING WITH POTABLE STORM SEWER, & POTABLE WATER MAIN COME IN CONTACT WITH ANY PART OF A WATER LINE AND POTABL LOCATED ON ONE SIDE OF THE SANITARY GRAVITY SEWER, STORM SEWER OR RECLAIMED SEPARATION NOTES & SOLUTIONS SANITARY SEWER MANHOLE OR STORM SEWER WATER LINE AT SUCH AN ELEVATION THAT THE CLEARANCE MAIN BOTTOM OF THE WATER MAIN IS AT LEAST 8" STRUCTURE. -rI' AS REQ'D SANITARY GRAVITY MAIN OTHER LINE. I 1. A MINIMUM HORIZONTAL SEPARATION OF TEN FINISHED GRADE rSANITARY AS REQ'D 4. IF THE MINIMUM ALLOWABLE TEN (10) FOOT SHALL BE MAINTAINED BETWEEN WATER MAIN, (10) FEET OUTSIDE TO OUTSIDE SHALL BE BETWEEN WATER MAINS AND HORIZONTAL SEPARATION OR EIGHTEEN (18)INCH TER MAIMAINTAINED 16. DEVIATIONS AND OTHER ALTERNATIVES J 1SANITARY GRAVITY SEWER OR STORM SEWER SHALL BE CONSIDERED ON CASE-BY-CASE BASIS GRAVITY - 6" MIN AND MUST RECEIVE SPECIFIC APPROVAL BY LINES. 11. WHEN THERE IS LESS THAN TWENTY FOUR MAIN OR STORM SEWER STORM SEWER.24 SEWER.( O 2. A MINIMUM HORIZONTAL SEPARATION WATER MAIN WATER MAIN AND STORM SEWER, THE WATER 17. THERE SHALL BE AN EIGHTEEN 18 INCH ( ) 5. IF THE NON -CONFORMING LINE IS A GRAVITY (3) FEET OUTSIDE TO OUTSIDE SHAA LL BEMAINTAINED VERTICAL SEPARATION BETWEEN WATER MAINS FINISHED GRADETHREE ONE FULL LENGTH OF PIPE SHALL BE CENTERED AND SANITARY SEWER FORCE MAINS AT BETWEEN WATER MAINS AND "REUSEWATERRECLAIMED CROSSING CROSSINGS WITHOUT EXCEPTION. CONFLICTS WITH INCHES VERTICAL SEPARATION IN A SEPARATE 6. MAINTAIN A MINIMUM OF 3' CLEARANCE FREE EXISTING LINES, WHERE IT IS NOT POSSIBLE TO WATER LINES CARRYING MAIN SHALLBEBURIED MAINTAIN THE REQUIRED SEPARATION, IT SHALL BE REPORTED TO AQUA NORTH CAROLINA, GRAVITY SANITARY SEWER (IF BEING NEWLY GRAVITY SEWER WHERE THERE IS LESS THAN EIGHTEEN (18) INCHES VERTICAL CLEARANCE INC./ENGINEER. SPECIAL SOLUTIONS MUST BE UNRESTRICTED PUBLIC ACCESS REUSE WATER. TO 6' AT HAZARD ACCEPTED BY NCDENR PRIOR TO Z 0 L GRAVITY SEWER TO DIP PVC AND IMPLEMENTATION. 3. IN AREAS WHERE IT IS NOT PRACTICAL TO INTERSECTIONS OR I ' MAINTAIN THE REQUIRED SEPARATION, THE WHERE CROSSING WITH POTABLE - WATER MAIN MUST BE LAID IN A SEPARATE TRENCH OR ON AN UNDISTURBED EARTH SHELF WATER LINE AND POTABL LOCATED ON ONE SIDE OF THE SANITARY GRAVITY SEWER, STORM SEWER OR RECLAIMED WILL MAINTAIN EIGHTEEN (18) INCH ATER WATER LINE AT SUCH AN ELEVATION THAT THE CLEARANCE MAIN BOTTOM OF THE WATER MAIN IS AT LEAST 8" 24.5" EIGHTEEN (18)INCHES ABOVE THE TOP OF THE AS REQ'D SANITARY GRAVITY MAIN OTHER LINE. 10. A MINIMUM OF VERTICAL SEPARATION OF OR STORM SEWER 24.5" EIGHTEEN (18) INCHES OUTSIDE TO OUTSIDE AS REQ'D 4. IF THE MINIMUM ALLOWABLE TEN (10) FOOT SHALL BE MAINTAINED BETWEEN WATER MAIN, TO MH. WITH STAINLESS STEEL PROJECT COORDINATOR. HORIZONTAL SEPARATION OR EIGHTEEN (18)INCH SANITARY GRAVITY SEWER, STORM SEWER OR 16. DEVIATIONS AND OTHER ALTERNATIVES VERTICAL SEPARATION IN A SEPARATE TRENCH RECLAIMED WATER LINES. SHALL BE CONSIDERED ON CASE-BY-CASE BASIS CANNOT MAINTAINED, UPGRADE THE WATER 6" MIN AND MUST RECEIVE SPECIFIC APPROVAL BY MAIN TO DUCTILE IRON IF THE OTHER LINE IS A D 11. WHEN THERE IS LESS THAN TWENTY FOUR NCDENR PRIOR TO IMPLEMENTATION STORM SEWER.24 SEWER.( 24) INCHES VERTICAL CLEARANCE BETWEEN THE E REMOVED FOR MAINTENANCE PURPOSES ♦ WATER MAIN AND STORM SEWER, THE WATER 17. THERE SHALL BE AN EIGHTEEN 18 INCH ( ) 5. IF THE NON -CONFORMING LINE IS A GRAVITY MAIN SHALL BE UPGRADED TO DUCTILE IRON. VERTICAL SEPARATION BETWEEN WATER MAINS SANITARY SEWER, AND TEN (10) FEET OF ONE FULL LENGTH OF PIPE SHALL BE CENTERED AND SANITARY SEWER FORCE MAINS AT HORIZONTAL SEPARATION OR EIGHTEEN (18) AT THE POINT OF CROSSING. CROSSINGS WITHOUT EXCEPTION. CONFLICTS WITH INCHES VERTICAL SEPARATION IN A SEPARATE 6. MAINTAIN A MINIMUM OF 3' CLEARANCE FREE EXISTING LINES, WHERE IT IS NOT POSSIBLE TO TRENCH CANNOT BE MAINTAINED. UPGRADE THE 12. IF THE NON -CONFORMING IS A SANITARY MAINTAIN THE REQUIRED SEPARATION, IT SHALL BE REPORTED TO AQUA NORTH CAROLINA, GRAVITY SANITARY SEWER (IF BEING NEWLY GRAVITY SEWER WHERE THERE IS LESS THAN EIGHTEEN (18) INCHES VERTICAL CLEARANCE INC./ENGINEER. SPECIAL SOLUTIONS MUST BE INSTALLED) TO ANNA C-900, D.R. 18 PVC AND HYDROSTATICALLY TEST IT TO 150psi. FROM THE WATER MAIN, UPGRADE THE SANITARY ACCEPTED BY NCDENR PRIOR TO Z 0 L GRAVITY SEWER TO DIP PVC AND IMPLEMENTATION. 6. IF THE OTHER LINE IS A RECLAIMED WATER HYDROSTATICALLY TEST IT TO WATER MAIN A RECESSED NUT. LINE AND THE ABOVE SEPARATION STANDARDS. PIPES SHALL BE LOCATED SO THAT SDR 26 PVC REQUIREMENTS ARE NOT MET, UPGRADE THE JOINTS ARE AS FAR AS POSSIBLE FROM EACH RECLAIMED WATER LINE MATERIAL TO DUCTILE OTHER. \ IRON. 13. IF THE OTHER LINE IS A RECLAIMED WATER CONFIGURATION IN ACCORDANCE WITH STANDARD 7. DEVIATIONS AND OTHER ALTERNATIVES SHALL LINE AND THE ABOVE MINIMUM SEPARATION IS oa BE CONSIDERED ON CASE-BY-CASE BASIS AND NOT MET, UPGRADE THE RECLAIMED WATER LINE SDR 35 SW PVC 1/4 B�O MUST RECEIVE SPECIFIC APPROVAL BY AQUA MATERIAL TO DUCTILE IRON. NORTH CAROLINA, INC. AND NCDENR PRIOR TO 14. SPECIAL STRUCTURAL SUPPORT OR WHENEVER POSSIBLE. LOCATE DOUBLE LATERAL AS IMPLEMENTATION. CONCRETE SADDLES MAY BE NECESSARY AT THE 8. THERE SHALL BE AT LEAST A TEN (10) FOOT CROSSING LOCATION. SHELF. CONSTRUCT TROUGH 0 SEPARATION BETWEEN WATER MAINS AND 15. IT IS PREFERABLE TO LAY THE WATER MAIN N� SANITARY SEWER FORCE MAINS WITHOUT ABOVE THE CROSSING HAZARD. SEWER MAIN BELOW PRING LINE. EXCEPTION. FIELD PROBLEMS SHALL BE DISCHARGE IN THE DIRECTION REPORTED TO NCDENR/ENGINEER. SPECIAL J OF FLOW. m FRAME AND COVER "SANITARY" FINISH GRADE RUBBER CHIMNEY "" CONC. ADJUSTING SEAL RUNGS (5 MAX) 2 COATS (8 MIL 1' EA) COAL TAR EPDXY, INTERIOR & JOINTS ECCENTRIC CONICAL SECTION STRIP JOINT A-LOK OR LINK SEAL GASKET :v, SEALANT r RE -CAST CON(. CON( FILL BENCHING j i"YrAO_ #89 CRUSHED STONE MANHOLE SIZE UP TO 24" PIPE: 48" MANHOLE UP TO 36" PIPE: 60" MANHOLE OVER 36" PIPE: 72" MANHOLE NOTES: 1. PRE -CAST CONCRETE SHALL BE TYPE 2 CEMENT (4,000 PSI). 2. LIFT HOLES NOT PERMITTED THROUGH PRE -CAST SECTIONS. 3. ALL OPENINGS SHALL BE SEALED WITH NON -SHRINK GROUT. 4. INSTALL FLOW CHANNEL INSIDE MANHOLES. 5. SERVICE LATERALS SHALL GENERALLY NOT BE PERMITTED DIRECTLY INTO MANHOLES. 6. PLACE TWO HALF-MOON SHAPED PLYWOOD (3/8" TH. MIN.) IN BOTTOM OF MANHOLE AFTER PIPES HAVE BEEN CONNECTED TO KEEP DEBRIS FROM ENTERING SEWER. 7. REINFORCING STEEL PER ASTM C478 -88A. 8. PROVIDE 5' X 5' X 12" CONCRETE COLLAR AROUND COVER FRAME, WITH 4 - #4 REBAR E.W. IN UNPAVED AREAS. 9. PROVIDE PIPE TO MANHOLE SEAL, A-LOK GASKET PER ASTM C-433 SPECIFICATION CAST INTEGRALLY IN MANHOLE WALL AND LOCATED AS DIRECTED. GASKET DESIGNED TO MEET TEST AND PERFORMANCE REQUIREMENT OF ASTM C-425 SPECIFICATION. JOINT SHALL ALLOW 10' OMNIDIRECTIONAL DIRECTION. 10. JOINT SEALANT SHALL BE BUM RUBBER OR BITUMINOUS MASTIC GASKET PER ASTM C-990 SPECIFICATION. PROVIDE BUTYL-LOK BY A-LOK PRODUCTS, INC. 11. MANHOLE STEPS SHALL BE j INCH GRADE 60 STEEL ENCAPSULATED IN POLYPROPYLENE CONFORMING TO ASTM C478. 12. MANHOLE FRAME AND GASKETED COVER SHALL BE NEENAH MODEL R-1743 OR AN APPROVED EQUAL. 13. SEAL MANHOLE FRAME AND GRADE RINGS WITH WRAPOSEAL HEAT SHRINK ENCAPSULATION SYSTEM BY CANUSA-CPS, INC. 14. MANHOLES GREATER THAN 15' SHALL HAVE AN INTERMEDIATE LANDING CONSTRUCTED OF PRECAST CONCRETE. 15. MANHOLE UPSTREAM OF WW PLANT SHALL BE A GRIT TRAP TYPE WITH 2" SUMP. AQUA 16 STANDARD MANHOLE DETAIL 05/2012 Aqua North Carolina, Inc. 114- MANHOLE MH DEPTH A B C D E F UP TO 12' 48" 8" 24.5" 15" AS REQ'D 8" 12' TO 18' 60" 8" 24.5" 15" AS REQ'D 10" 18' AND DEEPER 72" 8" 24.5" 15" AS REQ'D 1 NON-SKID SURFACE FOR PERSONNEL SAFETY I ti I SLOPE J,'' I d I 11C ONCRETE BONDING AGENT SEE NOTE AOUA Rll®011 GlE -�- Aqua North Carolina, Inc. E PIPE & MANHOLE FT MIN. SLOPE\ I /MIN. SLOPE I PIPE & MANHOLE NCH BEN( MANHOLE RADIUS TO BE y/ AXIMUM POSSIBLE & CHANNEL I TO BE TROWEL FINISH 4,000 PSI I d i ` „ONCRETE BENCH & 1 1 1 CHANNEL ,r 1, t I• ENCH 1Z. 1 SLOPE SLOPE PC NOTE: MANHOLE CHUTE IS TO BE USED WHERE DIFFERENCE IN INVERT ELEVATIONS BETWEEN INCOMING PIPE AND OUTGOING PIPE IS LESS THAN 24". IF THE DIFFERENCE IS 24" OR GREATER, THEN DROP CONNECTION SHALL BE USED. 14,000 PSI CONCRETE BENCH AND CHANNEL MIN AASHTO NO. 57 dPACTED STONE 2, AQU A MANHOLE CHUTE 05/2012 Aaua North Carolina. Inc. \ A I \ 1 }• SLEEVING I I C 60 OAD \ FOR SINGLE ROW \ SERVICES I \ B \ � A 1 �" SLEEVING OR \ GREATER FOR DOUBLE SERVICES 1 WATER MAIN I I 3' FROM EDGE I I WATER MAIN OF PAVEMENT I I 1 I I I I I I / SLEEVING I 4 \ 1 1 R SI GREATER FOR SINGLE SERVICE/ i •ice \ `\ � \ 1 I � / I AQUA NEW l \7,•: SANITARY �t\�y SEWER A ` 1'7(1/8" STAINLESS ;`•,; `•'.� STEEL STRAP * NOTES 5. DROP STRUCTURE MH. SHALL BE A MIN. N MANHOLE SHALL BE IN OF 5' DIAMETER TO 12" ABOVE TEE. DROP ACCORDANCE WITH AQUA NORTH STRUCTURE SHALL BE INSTALLED AGAINST CAROLINA STANDARDS, SEE WALL OF MANHOLE AS SHOWN. IF THE GRADE MANHOLE DETAIL FOR ADDITIONAL DOES NOT ALLOW, THEN INSTALL AS CLOSE TO INFORMATION WALL AS POSSIBLE. 2. ALL PVC FITTINGS FOR DROP 6. DROP STRUCTURES REQUIRED FOR ALL STRUCTURE SHALL BE SDR 35 PVC DROPS 6" AND GREATER IN DIAMETER, AND WITH SOLVENT WELD JOINTS WHEN 3 OR MORE 4" LATERALS ENTER 3. MANHOLES GREATER THAN 12' MANHOLES WITH 4" INTERIOR DROPS. NO MORE IN DEPTH SHALL HAVE MIN. 6" THAN FOUR 4" INTERIOR DROPS ARE ALLOWED A EXTENDED BASE. IN A 5' MANHOLE. 4. DROP STRUCTURE SHALL BE 7. NO MORE THAN 4, FOUR INCH LATERALS OR PLACED WHERE SEWER MAIN OR 3, SIX INCH LATERALS SHALL ENTER A 4' LATERAL VERTICAL DROP BETWEEN DIAMETER TERMINAL MANHOLE. NO MORE THAN INVERTS EXCEEDS 2.00'. 2 LATERALS (REGARDLESS OF SIZE) SHALL ENTER ALL OTHER 4' DIAMETER MANHOLES. ALL NOTE 1. THE SITE DEVELOPER SHALL LEAVE THE o am NONE LATERALS SHALL HAVE AN INDIVIDUAL TROUGH. CLEANOUT RISER 3'-4' ABOVE GRADE AND IT SHALL PLAN 5' DIAMETER MANHOLES SHALL BE USED IF THE O LO REMAIN SO UNTIL LOT BUILD OUT. THE RISER 9 TEE WITH OPEN EN SHALL THEN BE CUT AND CAPPED AT FINISHED CL � ON SPIGOT SIDE THE SHELF. 8. NO MORE THAN 5 LATERALS SHALL 10. CONNECTIONS TO EXISTING GRADE WITH A CONCRETE PAD. cc "DOWNSTREAM" Z 2. ALL CLEANOUTS TO BE FLUSH WITH FINISH - o LOT LINE CLEANOUT GRADE. 1 NON -SHRINK GROUT SEAL TO MH. WITH STAINLESS STEEL PROJECT COORDINATOR. 3. UTILITY CONTRACTOR TO INSTALL &PRESSURE O Z1 "Y' FIj TEST WYE AND INSTALL PLUG. PLUMBER TO -L• O 3 6" MIN REMOVE PLUG, INSTALL CLEANOUT AND CONCRETE PAD. z 30' BE 4. MARK CURB WITH 'S" WHERE LATERAL CROSSES 00 E REMOVED FOR MAINTENANCE PURPOSES ♦ UNDER CURB.5. 2" MIN. SW TEE SDR 3 a 2A COMPACTED, a4gIG�T ANPOT01 . ALL COMMERCIAL AND RESIDENTIAL SINGLE o� REMOVABLE STOPPER SEWER LATERALS SHALL HAVE 4" CLEANOUTS. TO SPRING -LINE OF PIPE A SET IN JOINT COMPOUND SIZE V 6. MAINTAIN A MINIMUM OF 3' CLEARANCE FREE (900 BELL X SDR 26 rn 1"x 1/8" ST�IRNSt OF ALL PLANTINGS & STRUCTURES AROUND W W STRAPS CONFORMING TO THE LDER VALV CLEANOUT. PIPE ANCHORED WITH FLEXIBLE BOOT Z 0 L 7. CLEANOUT CAPS SHALL BE SLOTTED OR HAVE PLAN A RECESSED NUT. Z N 2 STRAPS MINIMUM, STRAP SDR 26 PVC 8. CLEAN - OUT (SHOWN DASHED) SHALL BE SHALL BE 3' O.C. MAX. PLACE � INSTALLED BY THE UTILITY CONTRACTOR TO FINAL \ W¢' WITHIN 1' OF j BEND. ALL CONFIGURATION IN ACCORDANCE WITH STANDARD r in OTHER STRAPS SHALL BE 3' oa PLUMBING CODE. 00 Z SDR 35 SW PVC 1/4 B�O 9. DOUBLE LATERALS ARE TO BE AVOIDED TOWARD INVERT OUT. BEND SW } BEND SDR 3 WHENEVER POSSIBLE. LOCATE DOUBLE LATERAL AS N SHALL BE PLACED ON TOP OF CLOSE TO LOT LINE AS POSSIBLE, 5' MAXIMUM. r SHELF. CONSTRUCT TROUGH 0 10. INVERT OF SERVICE LATERAL SHALL NOT ENTER N� TOP OF SHELF TO DIRECT SECTION "A -A" SEWER MAIN BELOW PRING LINE. o DISCHARGE IN THE DIRECTION 11. DOUBLE SERVICE LATERAL TO BE USED ONLY J OF FLOW. WHEN WHEN BOTH BUILDING SLABS ARE NOT ¢ AQUA NORTH CAROLINA Q GREATER THAN 4" -INCHES ELEVATION DIFFERENCE. <' RESPONSIBILITY 12. SERVICE LATERA PIPING AND FITTINGS TO BE L, BY PLUMBE 6" SDR35 PVC UNLESS OTHERWISE NOTED. PROVIDE BRASS RING & PLUG (GASKETED ONLY) cwi w IN TRAFFIC AREAS 13. INSTALL 4"X4" (TOP ONE -FOOT PAINTED GREEN) L) z AND 3M MAGNETIC MARKER TO IDENTIFY LOCATION zi OF CLEANOUT(s) AT THE PROPERTY LINE N 6" PVC RISER 3 BY LICENSED UNDERGROUND 14. ALL LATERALS SHALL HAVE C.O. SET ® 2 -FT J \ (SINGLE PIECE) I� UTILITY CONTRACTOR BACK OF CURB OR 2 -FT BACK OF SIDEWALK. IF c) LDER VALVE SIDEWALK IS IMMEDIATELY ADJACENT TO CURB, DO NOT PLACE C.O. IN SIDEWALK. TERMINAL DEPTH AS 15. AQUA NORTH CAROLINA, INC. REQUIRED FOR HOUSE 2% MIN. BEND REPAIR/MAINTENANCE RESPONSIBILITY FOR SERVICE 18" MIN, 5'-0" I ( SANITARY LATERALS IS FROM THE MAINLINE TO THE MAX) 6" MINIMUM C.O. DESCRIBED IN THE NOT ABOVE. THE PROPERTY OWNER IS RESPONSIBLE UPSTREAM OF C.O. 16. PVC SDR -26 SHALL BE USED FROM THE C.O. ROTATE 30' (TYP) TO THE MAINLINE WHERE AQUA NORTH CAROLINA, 45' MAX INC. IS RESPONSIBLE FOR REPAIR/MAINTANCE. SEWER MAIN - SIZE VARIES COMBINATION WYE N N PROFILE 3 0 E PIPE & MANHOLE FT MIN. SLOPE\ I /MIN. SLOPE I PIPE & MANHOLE NCH BEN( MANHOLE RADIUS TO BE y/ AXIMUM POSSIBLE & CHANNEL I TO BE TROWEL FINISH 4,000 PSI I d i ` „ONCRETE BENCH & 1 1 1 CHANNEL ,r 1, t I• ENCH 1Z. 1 SLOPE SLOPE PC NOTE: MANHOLE CHUTE IS TO BE USED WHERE DIFFERENCE IN INVERT ELEVATIONS BETWEEN INCOMING PIPE AND OUTGOING PIPE IS LESS THAN 24". IF THE DIFFERENCE IS 24" OR GREATER, THEN DROP CONNECTION SHALL BE USED. 14,000 PSI CONCRETE BENCH AND CHANNEL MIN AASHTO NO. 57 dPACTED STONE 2, AQU A MANHOLE CHUTE 05/2012 Aaua North Carolina. Inc. \ A I \ 1 }• SLEEVING I I C 60 OAD \ FOR SINGLE ROW \ SERVICES I \ B \ � A 1 �" SLEEVING OR \ GREATER FOR DOUBLE SERVICES 1 WATER MAIN I I 3' FROM EDGE I I WATER MAIN OF PAVEMENT I I 1 I I I I I I / SLEEVING I 4 \ 1 1 R SI GREATER FOR SINGLE SERVICE/ i •ice \ `\ � \ 1 I � / I AQUA NEW l \7,•: SANITARY �t\�y SEWER A ` 1'7(1/8" STAINLESS ;`•,; `•'.� STEEL STRAP * NOTES 5. DROP STRUCTURE MH. SHALL BE A MIN. N MANHOLE SHALL BE IN OF 5' DIAMETER TO 12" ABOVE TEE. DROP ACCORDANCE WITH AQUA NORTH STRUCTURE SHALL BE INSTALLED AGAINST CAROLINA STANDARDS, SEE WALL OF MANHOLE AS SHOWN. IF THE GRADE MANHOLE DETAIL FOR ADDITIONAL DOES NOT ALLOW, THEN INSTALL AS CLOSE TO INFORMATION WALL AS POSSIBLE. 2. ALL PVC FITTINGS FOR DROP 6. DROP STRUCTURES REQUIRED FOR ALL STRUCTURE SHALL BE SDR 35 PVC DROPS 6" AND GREATER IN DIAMETER, AND WITH SOLVENT WELD JOINTS WHEN 3 OR MORE 4" LATERALS ENTER 3. MANHOLES GREATER THAN 12' MANHOLES WITH 4" INTERIOR DROPS. NO MORE IN DEPTH SHALL HAVE MIN. 6" THAN FOUR 4" INTERIOR DROPS ARE ALLOWED A EXTENDED BASE. IN A 5' MANHOLE. 4. DROP STRUCTURE SHALL BE 7. NO MORE THAN 4, FOUR INCH LATERALS OR PLACED WHERE SEWER MAIN OR 3, SIX INCH LATERALS SHALL ENTER A 4' LATERAL VERTICAL DROP BETWEEN DIAMETER TERMINAL MANHOLE. NO MORE THAN INVERTS EXCEEDS 2.00'. 2 LATERALS (REGARDLESS OF SIZE) SHALL ENTER ALL OTHER 4' DIAMETER MANHOLES. ALL Q o 1 Z ¢ o am NONE LATERALS SHALL HAVE AN INDIVIDUAL TROUGH. PLAN 5' DIAMETER MANHOLES SHALL BE USED IF THE O LO SDR 35 PVC SW ABOVE CONDITIONS ARE NOT MET. THE TEE WITH OPEN EN LATERAL INVERT SHALL BE AT THE TOP OF CL � ON SPIGOT SIDE THE SHELF. 8. NO MORE THAN 5 LATERALS SHALL 10. CONNECTIONS TO EXISTING FLEXIBLE BOOT CONNECTED ENTER A 5' DIAMETER TERMINAL MANHOLES SHALL HAVE CORE Z TO MH WITH SS EXP. RING MANHOLE. AND "BOOT" ONLY UNLESS n ® 9. FLEX. BOOT SHALL BE CONNECTED APPROVED OTHERWISE BY PWC J NON -SHRINK GROUT SEAL TO MH. WITH STAINLESS STEEL PROJECT COORDINATOR. O EXPANSION RING. FLEXIBLE BOOT 11. ALL MANHOLES SHALL BE L'' o SDR 26 PVC CONNECTORS SHALL CONFORM TO ASTM VACUUM TESTED IN w 6" MIN - C 923 SPEC. ACCORDANCE W AQUA NORTH J 0 PORTION OF TEE TO CAROLINA STANDARDS. M 12" MAX FOR TRANSITION FROM D.I. TO E REMOVED FOR MAINTENANCE PURPOSES z PVC. USE C900 BELL X SD 12 2" MIN. SW TEE SDR 3 a 2A COMPACTED, a4gIG�T ANPOT01 . GROUT SEALED, o� STONE FROM UNDISTURBED SOIL FOR TRANSITION FROM o TO SPRING -LINE OF PIPE A D.I. TO PVC USE A 2" MIN. o DIRECTED BY PWC PROJECT (900 BELL X SDR 26 rn 1"x 1/8" ST�IRNSt SPIGOT ADAPTOR. W W STRAPS CONFORMING TO THE DR 26 PV PIPE ANCHORED WITH FLEXIBLE BOOT Z 0 L STAINLESS STEEL ANCHOR BOLTS AND WEDGE ANCHORS. Z N 2 STRAPS MINIMUM, STRAP SDR 26 PVC SHALL BE 3' O.C. MAX. PLACE � STRAPS WITHIN 1' OF TEE AND \ W¢' WITHIN 1' OF j BEND. ALL SS STRAP r in OTHER STRAPS SHALL BE 3' oa 00 Z SDR 35 SW PVC 1/4 B�O TOWARD INVERT OUT. BEND SW } BEND SDR 3 N SHALL BE PLACED ON TOP OF aD N SHELF. CONSTRUCT TROUGH 0 N� TOP OF SHELF TO DIRECT SECTION "A -A" �o DISCHARGE IN THE DIRECTION ! OF FLOW. Behold, a virgin shall be with child, and shall bring forth a son, and they shall call his name Emmanuel, which being interpreted is, God with us. Matthew 1:23 BLN=C-1874 CARO 041;9. 4, SEAL 19843 F,y ��• .INE, 2/1/19 AQUA SEWER DETAILS REVISIONS FILE NO. 2018-033 00 (0 AS NOTED o am NONE 7� xl O LO M O^ . N CL � N W Z O CL O Z_ CC W W Z_ 0 Z W Z (n Y U O In WI- ?� W W WV) (n Z 0 L • Z N = U Z � Z F -W J W¢' 0 W = r in oa 00 Z BLN=C-1874 CARO 041;9. 4, SEAL 19843 F,y ��• .INE, 2/1/19 AQUA SEWER DETAILS REVISIONS FILE NO. 2018-033 HORZ. SCALE: AS NOTED VERT. SCALE: NONE 03 PAVEMENT OR 90' BEND FINISHED GRADE 22 1/2' BEND 11 1/4' BEND GATE VALVE TO BE SAME SEE VALVE BOX INSTALLATION 4" MIN. DIAMETER AS MAIN LINE Approved By: I VALVE A TAMPED BACKFILL BOX TAMPED THREADED COUPLING BACKFILL ;• — 2" THREADED BRASS PIPE D.I. PIPE CONCRETE BLOCKING ''^' A MIN. 1/3 C.Y. AT 3000 P.S.I ANCHOR FACE TOWARDS VALVE. TYPE 304 STAINLES CAST IN CONC. & CONCRETE THRUST THREADED RODS (MIN. 4 EA ) 6• COLLAR THREADED PIPE (12"IN LENGTH) 5' MIN. MJ CAP W/ 2" AP PAY ITEM 6• INCLUDES ALL ITEMS EXCEPT TWO MAIN LINE VALVE 1'-4" V-4" TEMPORARY BLOW -OFF ASSEMBLY NOT TO SCALE 6• Name Date JOHNSTON COUNTY Department of Public Utilities P.O. Box 2263 Smithfield, NC 27577 WATER STANDARD DETAIL Temporary Blow Off Assembly PAGE of 47 Drawn By: Checked By: Approved By: Scale: I 2. CONC. THRUST Rev. Description Date Ini,. NOTES: 1. CONCRETE SHALL BE 3,000 PSI MIN. 2. CONCRETE FOR THRUST BLOCKING SHALL BE KEPT FAIRLY DRY, THUS MAKING THE CONCRETE WEDGE SHAP MORE EASILY FORMED WITH THE WIDEST PART (BLOCKING AREA) AGAINST UNDISTURBED SOIL. 3. NO CONCRETE SHALL COVER ANY BOLTS OR GLANDS. 4. ALL FITTING AND ACCESSORIES TO BE WRAPPED WITH 10 MIL POLYETHYLENE PRIOR TO POURING BLOCKING. 5. VOLUME OF THRUST BLOCKING SHAL BE AS SHOWN ON THE THRUST BLOCKING SCHEDULE. PLAN BENDS PLAN TEES 18" MIN. - 10" 0 & LESS 24" MIN. - 12" 0 & GREATER " d -{ MIN. UU` ci SECTION X -X PLAN & ELEV. BENDS & TEES PLUGS PIPE 90' BEND 45' BEND 22 1/2' BEND 11 1/4' BEND PAGE 8 of 47 TEE41r25' Checked By: Approved By: I S ZE A B A B A B A B A . ANCHOR FACE TOWARDS VALVE. - CAST IN CONC. & 1Y 6• W 6• 6• 6• 6• a• TWO 4. CONTRACTOR SHALL "1 1'-4" V-4" 6• 10• 12, 6• 10• W a• W 6• 10• EMBED. iv GATE VALVE 2. CONC. THRUST B• 15 13" UP 10• W e" W B" 1o" TYPE 304 S.S. THREADED RODS BANK (MORE IF 10• 18• 14 10" 12, 6• 1C' 6• 10• 11• 4. FIRE HYDRANT Name Date JOFNSTON COUNTY Department of Public Utilities P.O. Box 2263 Smithfield, NC 27577 1Y 20• 18• 1Y 14• W 17 B• 12• 14 ~W J W 14• 22" 1B" 14 IV 10" 14 10" 14" 16" 16• 18" 3C 18" 26" 20" 18• 16" 12" 16" 12" 16" 16" 20• 20" 36" 20• 36• 26• 2C 18• 18• 13• 12• V IV 1a• 24• 46• 24• 46" 33" 30• 21• 18" 1B" 15 11• 21" 21• 26• 56" 04 00 THRUST BLOCK DETAIL NOT TO SCALE Name Date JOHNSTON COUNTY partment of Public Utilities P.O. Box 2263 Smithfield, NC 27577 WATER STANDARD DETAIL Thrust Block PAGE 8 of 47 Drawn By: Checked By: Approved By: I Scale: I BARS Rev. I Description I Date Init. PAVEMENT OR FINISHED GRADE SEE VALVE BO 4" MIN. TAMPED BACKFILL INSTALLATION 5/8" TYPE 304 STAINLESS STEEL VALVE THREADED RODS (MIN. 4 EA.) BQX,,, TAMPED THREADED COUPLING BAGKFI 2" BRASS NIPPLE D.I. PIP i,+,• '' ;'. •`•; • CONCRETE BLOCKING CONCRETE THRUST 2" BRASS NIPPLE MIN. 1/3 C.Y. AT 3000 .S. COLLAR (MIN. 6- IN LENGTH) M.J. CAP W/ 5' MIN. 2" THREADED TAP 2" BRASS PIPE (MIN. 12" IN LENGTH) PAY ITEM INCLUDES ALL ITEMS PERMANENT BLOW -OFF ASSEMBLY NOT TO JOHNSTON COUNTY Department of Public Utilities P.O. Box 2263 Smithfield, NC 27577 5 1 O JOHNSTON COUNTY NOTES: NOTE: ' 6" TO 16" MAINS = 12-N0. 7 M 1. VALVE MARKERS SHALL IT;N BARS n 20" TO 36" MAINS = 12-N0. BE PLACED AT R/W. CONCRETE THRUST 8 BARS — _COLLAR (3,000 P.S.I.) BARS PLACED AS SHOWN — - —III=1 I 1=1 I 1=1 11= IWI 2. LETTERS "MV" SHALL • . ANCHOR FACE TOWARDS VALVE. - CAST IN CONC. & RING 3. MARKER SHALL HAVE FINISHED GRADE1 I • '• PAINTED BLACK TRENCH WALL BRASS OR BRONZE EMBED ON TOP OR SIDE. •.n° TAMPED BACKFILL TWO 4. CONTRACTOR SHALL "1 1'-4" V-4" 4 E - f REBAR TWo STAMP DISTANCE TO CONCRETE THRUST BLOCK (1 EA. CORR NEER)R) E CENTER OF VALVE INTO _ AT 3,000 P.S.I. . °•° EMBED. iv GATE VALVE 2. CONC. THRUST Z W 5. BLOW -OFF ASSEMBLY VALVE CED ON THE SQUARE MARKER • SHALL INCLUDE 1 EA. OF 6 SQ. FT. (4 C.F. MIN.) WITH BEVELED CORNERS O MARKER W/ "BO" OR "MV" TYPE 304 S.S. THREADED RODS BANK (MORE IF CAST. MIN. 2 EA. PER SEGMENT REQ'D.). TAMPED VALVE MARKER DETAIL PAY ITEM NOT TO SCALE FLANGES SHALL BE FIRE HYDRANT ASSEMBLY INCLUDES GRIP RINGS MAY BE USED AT CLEAR OF CONC. ALL ITEMS EXCEPT MAIN LINE TEE JOINTS IN LIEU OF THREADED RODS 4. FIRE HYDRANT Name Date JOFNSTON COUNTY Department of Public Utilities P.O. Box 2263 Smithfield, NC 27577 ' WATER STANDARD DETAIL Valve Marker PAGE 15 of 47 Drawn By: Checked By: Approved By I Scale: Rev. I Description I Date linit. PAVEMENT OR FINISHED GRADE SEE VALVE BO 4" MIN. TAMPED BACKFILL INSTALLATION 5/8" TYPE 304 STAINLESS STEEL VALVE THREADED RODS (MIN. 4 EA.) BQX,,, TAMPED THREADED COUPLING BAGKFI 2" BRASS NIPPLE D.I. PIP i,+,• '' ;'. •`•; • CONCRETE BLOCKING CONCRETE THRUST 2" BRASS NIPPLE MIN. 1/3 C.Y. AT 3000 .S. COLLAR (MIN. 6- IN LENGTH) M.J. CAP W/ 5' MIN. 2" THREADED TAP 2" BRASS PIPE (MIN. 12" IN LENGTH) PAY ITEM INCLUDES ALL ITEMS PERMANENT BLOW -OFF ASSEMBLY NOT TO JOHNSTON COUNTY Department of Public Utilities P.O. Box 2263 Smithfield, NC 27577 WATER PAGE STANDARD DETAIL A Permanent Blow Off G Assembly of 47 r 4'-0" tB CONCRETE THRUST � I COLLAR (3,000 P.S.I.) A 1' ANCHOR i "C D.I.P. RING MAIN t 4 SECTION O JOHNSTON COUNTY NE NOTE: ' 6" TO 16" MAINS = 12-N0. 7 WATER PAGE STANDARD DETAIL A Permanent Blow Off G Assembly of 47 r 4'-0" tB CONCRETE THRUST � I COLLAR (3,000 P.S.I.) A 1' ANCHOR i "C D.I.P. RING MAIN t 4 THRUST COLLAR INSTALLATION NOT TO SCALE Name Date Drawn By: PAGE Checked By: JOHNSTON COUNTY WATER Approved By: Department of Public Utilities STANDARD DETAIL 9 Scale: P.O. Box 2263 Thrust Collar J Smithfield, NC 27577 Installation of 47 Rev. Description jDate Ilnit. NOTE: PIPE SHALL BE BEDDED UP TO SPRING LINE AND MINIMUM 4" BELOW BOTTOM OF PIPE WHEN WET AREAS ARE ENCOUNTERED. HAND PLACED DENSELY COMPACTED BACKFILL TO 1 FT. ABOVE TOP OF PIPE- il UNDISTURBED EARTH - - - - - ELECTRONIC MARKER BALLS AT 100' ON - CENTER & AT BENDS. MARKER BALLS SHALL BEDDED PIPE _ -O.D.- = BE INSTALLED AT 1 1/2 TO 2' DEEP. -_ - - _= NOTE: MARKER BALLS SHALL BE SHAPED SUBGRADE - - INSTALLED CONCURRENTLY WITH PIPE. MARKER BALLS SHALL NOT BE SHALL PROVIDE BEARING - - INSTALLED AFTER TRENCH HAS BEEN ALONG ENTIRE LENGTH OF PIPE BARREL COMPLETELY BACKFILLED. /2 PIPE O.D. 24" + O.D. MAX. 12" + O.D. MIN. NOTE: WATER MAINS 8"0 AND SMALLER SHALL HAVE MINIMUM OF 3' COVER. WATER MAINS LARGER THAN 8"0 SHALL HAVE A MINIMUM OF 3'-6" COVER. PIPE LAYING CONDITION NOT TO SCALE I Checked By: I I I JOHNSTON COUNTY Department of Public Utilities P.O. Box 2263 Smithfield, NC 27577 WATER PAGE STANDARD DETAIL 16 Pipe Laying Condition of 47 OAT HYDRANT BONNET AND NOZZLE CAPS "ALERT" REFLECTIVE FIRE HYDRANT PAINT SILVER MODEL #1440 SECTION REINFORCING JOHNSTON COUNTY PIPE DIAMETER NOTE: ANCHOR COLLAR 6" TO 16" MAINS = 12-N0. 7 UNDISTURBED BARS SOIL 20" TO 36" MAINS = 12-N0. 6•,6•,12• CONCRETE THRUST 8 BARS — _COLLAR (3,000 P.S.I.) BARS PLACED AS SHOWN — - —III=1 I 1=1 I 1=1 11= -III—III—III—. • . ANCHOR a - D.I.P. TRENCH WALL RING 11 • '• MAIN TRENCH WALL _ 1i_ •.n° TAMPED BACKFILL TWO 36• 1'-4" V-4" 4" TWo •• CONCRETE THRUST BLOCK PLAN UNDISTURBED E SOIL THRUST COLLAR INSTALLATION NOT TO SCALE Name Date Drawn By: PAGE Checked By: JOHNSTON COUNTY WATER Approved By: Department of Public Utilities STANDARD DETAIL 9 Scale: P.O. Box 2263 Thrust Collar J Smithfield, NC 27577 Installation of 47 Rev. Description jDate Ilnit. NOTE: PIPE SHALL BE BEDDED UP TO SPRING LINE AND MINIMUM 4" BELOW BOTTOM OF PIPE WHEN WET AREAS ARE ENCOUNTERED. HAND PLACED DENSELY COMPACTED BACKFILL TO 1 FT. ABOVE TOP OF PIPE- il UNDISTURBED EARTH - - - - - ELECTRONIC MARKER BALLS AT 100' ON - CENTER & AT BENDS. MARKER BALLS SHALL BEDDED PIPE _ -O.D.- = BE INSTALLED AT 1 1/2 TO 2' DEEP. -_ - - _= NOTE: MARKER BALLS SHALL BE SHAPED SUBGRADE - - INSTALLED CONCURRENTLY WITH PIPE. MARKER BALLS SHALL NOT BE SHALL PROVIDE BEARING - - INSTALLED AFTER TRENCH HAS BEEN ALONG ENTIRE LENGTH OF PIPE BARREL COMPLETELY BACKFILLED. /2 PIPE O.D. 24" + O.D. MAX. 12" + O.D. MIN. NOTE: WATER MAINS 8"0 AND SMALLER SHALL HAVE MINIMUM OF 3' COVER. WATER MAINS LARGER THAN 8"0 SHALL HAVE A MINIMUM OF 3'-6" COVER. PIPE LAYING CONDITION NOT TO SCALE I Checked By: I I I JOHNSTON COUNTY Department of Public Utilities P.O. Box 2263 Smithfield, NC 27577 WATER PAGE STANDARD DETAIL 16 Pipe Laying Condition of 47 OAT HYDRANT BONNET AND NOZZLE CAPS "ALERT" REFLECTIVE FIRE HYDRANT PAINT SILVER MODEL #1440 SCHEDULE PUMPING & HOSE CONNECTIONS JOHNSTON COUNTY PIPE DIAMETER CONCRETE THRUST DOLLAR ANCHOR COLLAR RINGS REWIRED BREAK RING TO BE SET WITHIN 2"-4" A B C OF FINISHED GRADE 6•,6•,12• 1'-0• 1'-0" 2" ONE 16 1'-4' 1'-0" 2• ONE 20" 1'-4" 1-0• 3" ONE 24" 1'-4" V-0• 3" TWO 30• 1'-4" 1'-2" 4• TWO 36• 1'-4" V-4" 4" TWo THRUST COLLAR INSTALLATION NOT TO SCALE Name Date Drawn By: PAGE Checked By: JOHNSTON COUNTY WATER Approved By: Department of Public Utilities STANDARD DETAIL 9 Scale: P.O. Box 2263 Thrust Collar J Smithfield, NC 27577 Installation of 47 Rev. Description jDate Ilnit. NOTE: PIPE SHALL BE BEDDED UP TO SPRING LINE AND MINIMUM 4" BELOW BOTTOM OF PIPE WHEN WET AREAS ARE ENCOUNTERED. HAND PLACED DENSELY COMPACTED BACKFILL TO 1 FT. ABOVE TOP OF PIPE- il UNDISTURBED EARTH - - - - - ELECTRONIC MARKER BALLS AT 100' ON - CENTER & AT BENDS. MARKER BALLS SHALL BEDDED PIPE _ -O.D.- = BE INSTALLED AT 1 1/2 TO 2' DEEP. -_ - - _= NOTE: MARKER BALLS SHALL BE SHAPED SUBGRADE - - INSTALLED CONCURRENTLY WITH PIPE. MARKER BALLS SHALL NOT BE SHALL PROVIDE BEARING - - INSTALLED AFTER TRENCH HAS BEEN ALONG ENTIRE LENGTH OF PIPE BARREL COMPLETELY BACKFILLED. /2 PIPE O.D. 24" + O.D. MAX. 12" + O.D. MIN. NOTE: WATER MAINS 8"0 AND SMALLER SHALL HAVE MINIMUM OF 3' COVER. WATER MAINS LARGER THAN 8"0 SHALL HAVE A MINIMUM OF 3'-6" COVER. PIPE LAYING CONDITION NOT TO SCALE I Checked By: I I I JOHNSTON COUNTY Department of Public Utilities P.O. Box 2263 Smithfield, NC 27577 WATER PAGE STANDARD DETAIL 16 Pipe Laying Condition of 47 OAT HYDRANT BONNET AND NOZZLE CAPS "ALERT" REFLECTIVE FIRE HYDRANT PAINT SILVER MODEL #1440 NOT TO SCALE WATER PUMPING & HOSE CONNECTIONS JOHNSTON COUNTY PLACE EQUAL TO COUNTY STANDARD 'do STANDARD DETAIL BREAK RING TO BE SET WITHIN 2"-4" FINISHED GRADE Fire Hydrant OF FINISHED GRADE Smithfield, NC 27577 Assembly VALVE BOX SELECTED HYDRANT TEE BURY IAS I I I I I I I I I I I I I I I I I I I I I I ' 'III WATERLINESIZE VARIES SPECIFIED I SEE PLANS CONCRETE THRUST BLOCK PRIMARY HIGHWAYS TRANSVERSE AND LONGITUDINAL CUTS DETAILS FOR NOTE: REPLACING PAVEMENT O 1. MIN. OF 4 CU. FT. ENCASEMENT d •• CONCRETE THRUST BLOCK STONE (MORE IF E _ AT 3,000 P.S.I. REQ'D). °•° ' `�a •••4 •a•a; • ' GATE VALVE 2. CONC. THRUST Z W Z VALVE CED ON THE BLOCK TO HAVE Mll'*67 STONE FILL • WATER MAALL N SB EPL DITCH OF 6 SQ. FT. (4 C.F. MIN.) O BEARING ON SOLID TYPE 304 S.S. THREADED RODS BANK (MORE IF HYDRANT LEG TO DIP MIN. 2 EA. PER SEGMENT REQ'D.). TAMPED OR 3. DRAIN HOLES AND PAY ITEM Aqua -Grip" RINGS OR ROMAC FLANGES SHALL BE FIRE HYDRANT ASSEMBLY INCLUDES GRIP RINGS MAY BE USED AT CLEAR OF CONC. ALL ITEMS EXCEPT MAIN LINE TEE JOINTS IN LIEU OF THREADED RODS 4. FIRE HYDRANT BARREL SHALL BE ' PLUMB . l -.l-.—, NOT TO SCALE RESTRAINED FLANGE ADAPTER "UNIFLANGE" OR EQUAL kP(P CESSORY KIT "FIELD LOK" GASKET OR EQUAL DIP (BELL 3/4" THREADED TYPE 304 OR TYPE 316 S.S. RODS MIN. 4 EA. HARNESS RESTRAINT DETAIL NOT TO SCALE Name Date Drawn By: PAGE Checked By: JOHNSTON COUNTY WATER Approved By: Department of Public Utilities STANDARD DETAIL 10 Scale: P.O. Box 2263 Restraint Harness Smithfield, NC 27577 of 47 Rev. I Description I Date Init. 2• ASPHALTIC WATER PAGE JOHNSTON COUNTY PLACE 7;_0 'do STANDARD DETAIL A Department of Public Utilities P.O. Box 2263 Fire Hydrant 4 Smithfield, NC 27577 Assembly of 47 RESTRAINED FLANGE ADAPTER "UNIFLANGE" OR EQUAL kP(P CESSORY KIT "FIELD LOK" GASKET OR EQUAL DIP (BELL 3/4" THREADED TYPE 304 OR TYPE 316 S.S. RODS MIN. 4 EA. HARNESS RESTRAINT DETAIL NOT TO SCALE Name Date Drawn By: PAGE Checked By: JOHNSTON COUNTY WATER Approved By: Department of Public Utilities STANDARD DETAIL 10 Scale: P.O. Box 2263 Restraint Harness Smithfield, NC 27577 of 47 Rev. I Description I Date Init. 2• ASPHALTIC CUT TO CONC. OR AS IN NEAT EDGE PLACE 7;_0 'do EXISTING PAVEMENT CONCRETE 1Y-----•$1�6" W COMPACTED CRUSHER _ - _ - RUN STABIUZED MATH - - - 5% PORTLAND CEMENT BURIED - SELECTED _ PIPE BACKFILL TAMPED _ UNE IN LAYERS SECONDARY HIGHWAYS & CITY STREET 2• PLANT MIX ASPHA FOR USE IN UNPAVED AREAS OR CONCRETE MIX SAW TO NEAT EDGE #4 LONGITUDINAL 7;_0 TIE BARS EXISTING PAVEMENT CONCRETE 1Y-----•$1�6" IN PAVED AREA 1X2" Valve and Valve �r 1" FINISHED GRADE HB SELECTED BACKFILL - - NOTE: ALL PAVEMENT SHALL BE REPAIRED WITHIN TAMPED IN 6• - - THE SAME WEEK IT IS LAYERS - CUT. BURIED PIPE UNE PRIMARY HIGHWAYS TRANSVERSE AND LONGITUDINAL CUTS DETAILS FOR CUTTING AND REPLACING PAVEMENT I Checked BY: I I I JOHNSTON COUNTY Department of Public Utilities P.O. Box 2263 Smithfield, NC 27577 NOT TO SCALE WATER PAGE STANDARD DETAIL 17 Cutting and Replacing Pavement of 47 CONCRETE BLOCKING EXIST. WATER MAIN TAPPING SLEEVE TAPPING VALVE WITH VALVE BOX NEW WATER MAIN TAPPING SLEEVE&VALVE ASSEMBLY No Q SCALE NOTE: TAPPING SLEEVE SHALL BE FABRICATED OF TYPE 304 S.S. AND PROVIDE A 360' SEAL AROUND EXISTING PIPE WITH FULL CIRCUMFERENTIAL GASKET. Name Date Drawn By: WATER PAGE Checked By: JOHNSTON COUNTY Approved By: Department of Public Utilities STANDARD DETAIL C Scale: P.O. Box 2263 Tapping Sleeve and 5 Smithfield, NC 27577 Valve Assembly of 47 Rev.1 Description jDate Init. FOR USE IN PAVED AREAS FOR USE IN UNPAVED AREAS PAGE JOHNSTON COUNTY VALVE BOX COVER 7;_0 FINISHED GRADE 7J¢" MIN. �� IN PAVED AREA 1X2" Valve and Valve �r 1" FINISHED GRADE Smithfield, NC 27577 Box Installation of 47 11 IN UNPAVED AREA Scale: BASE COURSE Rey.1 Description jDate Init. W Z 6" MIN, _ _ - - CONCRETE O ENCASEMENT d •• Z_ TAMPED BACKFILL _ E _ AT 3,000 P.S.I. °•° ' `�a •••4 •a•a; • ' 0 Z W Z _— VALVE BOX • . O O •.e WF TAMPED WV) (n -- Z OJ O LQ - BACKFILL ' WATER MAIN - _ _ _ _ - = U (n • ' ' VALVE ~W J W 4 VALVE BOX U) Oa .G A COVER TAMPED BACKFILL BLOCKING CONCRETE ENCASEMENT SECTION PLAN AT 3,000 P.S.I. NOTES: 1. D.I.P. MAY BE USED FOR VALVE BOX EXTENSIONS. 2. VALVE BOX SHOULD NOT CONTACT WATER MAIN OR VALVE. 3. CONCRETE PROTECTOR RING MAY BE USED IN LIEU OF ENCASEMENT IN UNPAVED AREAS. VALVE AND VALVE BOX INSTALLATION NOT TO SCALE NOTE: ALL TAPS 2" AND SMALLER SHALL BE MADE WITH TAPPING SADDLE. ALL TAPS LARGER THAN 2" SHALL BE MADE WITH TAPPING SLEEVE AND VALVE. NO DIRECT TAPS SHALL BE MADE. TAPPING SADDLE SHALL BE BRASS OR BRONZE FOR "CC" THREADS WITH DOUBLE STRAPS, FORD S-90, MUELLER BR2B OR APPROVED EQUAL. TAPPING SLEEVE SHALL BE BRASS OR BRONZE FOR "CC" THREADS, FORD S-70, MUELLER H-134, JCM 403 OR APPROVED EQUAL FOR SDR -21 PVC. CLASS 20 POLYETHYLENE CORPORATION STOP SHALL BRONZE WITH "CC" THREADS, MUELLER B-25000, FORD F6600, JCM 403 OR APPROVED EQUAL DUCTILE IRON PIPE P.V.C. PIPE (CLASS 50 CEMENT LINED) (CLASS 200) NOTE: ALL TAPS TO BE MADE ON TOP QUARTER OF MAIN. STANDARD WATER TAP DETAIL NOT TO SCALE Name Date Drawn By: PAGE Checked By: JOFNSTON COUNTY WATER Approved By: Department of Public Utilities STANDARD DETAIL 19 Scale: P.O. Box 2263 Standard Water Tap Smithfield, NC 27577 of 47 Rev.1 Description IDatr,. Ilnit. Behold, a virgin shall be with child, and shall bring forth a son, and they shall call his name Emmanuel, which being interpreted is, God with us. Matthew 1:23 CONCRETE THRUST BLOCK AT 45' BEND. �;. SEE THRUST BLOCK DETAIL FOR DIMENSIONS OF BLOCK. 10' MAX. NOTE: ALL PIPE SEGMENTS LESS X" S.S. THREADED RODS THAN 10' SHALL REQUIRE J CCON�CORETDR408ST BLOCK SEE THRUST BLOCK DETAIL FOR DIMENSIONS OF BLOCK. ROD REQUIREMENTS SIZE OF 45' BEND STATIC THRUST IN POUNDS NUMBER OF RODS REQUIRED 6" 4,328 2 B. 7,694 2 12" 17,312 2 16" 30,779 4 20" 48,091 6 24" 69,252 8 GENERAL NOTES 1. RODS AND NUTS SHALL BE OF TYPE 304 OR TYPE 316 STAINLESS STEEL. 2. CONCRETE SHALL NOT CONTACT BOLTS OR ENDS OF MECHANICAL JOINT BENDS. VERTICAL BEND RODDING AND BLOCKING DETAIL NOT TO SCALE JOHNSTON COUNTY Department of Public Utilities P.O. Box 2263 Smithfield, NC 27577 WATER PAGE STANDARD DETAIL Critical Bend Rodding and Blocking Details of 47 #3 REBAR 10" 2 EA. i-2" M ° 4» Ff 24" NOTE: PROTECTOR RING SHALL BE 3,000 P.S.I. CONCRETE. CONCRETE PROTECTOR RING NOT TO SCALE JOHNSTON COUNTY Department of Public Utilities P.O. Box 2263 Smithfield, NC 27577 PAGE WATER STANDARD DETAIL 14 Concrete Protector Ring of 47 LID SHALL BE LABELED "WATER METER" AND SHALL BE "AMR" TYPE WITH METAL FLIP -UP LID AND 2" HOLE FINISHED GRADE METER (US GAL.) 99„X-4" 7" MIN' II- 13" MIN. CLEARANCE MIN. 4" WASHED STONE 2LOCK TYPE 0" MIN. METER CL STOP ANGLE CHECK BLOCK SUPPORT OR VALVE STONE AS NEEDED 7" 74" OR 1" CLASS 200 • POLYETHYLENE WATER SERVICE LINE WIDE BODY OR DOUBLE STRAP SADDLE METER YOKE SHALL BE COPPERSETTER MUELLER NO. H-1404-2, FORD NO. VH -72-7W OR APPROVED EQUAL FOR METER YOKE COMPLETE WITH �4" SERVICE DUAL PURPOSE FITTINGS CORP. STOP WATER MAIN U -QM. 1. CONTRACTOR SHALL PLACE METER BOX IN NON TRAFFIC AREA ONLY. 2. PLASTIC METER BOX SHALL BE CENTURY #1015, NDS D1200, OR APPROVED EQUAL 3. CONTRACTOR SHALL CENTER METER YOKE IN METER BOX. 4. METER YOKE TO MUELLER No. H-1404-2, FORD No. VH -72-7W OR APPROVED EQUAL. 5. METER TO MEET AWWA C-700-71 STDS. AND SPECS. 3/4" WATER PAGE JOHNSTON COUNTY 7;_0 Department of Public Utilities STANDARD DETAIL �� P.O. Box 2263 Valve and Valve WATER STANDARD DETAIL X" and 1" Water Meter Service Smithfield, NC 27577 Box Installation of 47 NOTE: ALL TAPS 2" AND SMALLER SHALL BE MADE WITH TAPPING SADDLE. ALL TAPS LARGER THAN 2" SHALL BE MADE WITH TAPPING SLEEVE AND VALVE. NO DIRECT TAPS SHALL BE MADE. TAPPING SADDLE SHALL BE BRASS OR BRONZE FOR "CC" THREADS WITH DOUBLE STRAPS, FORD S-90, MUELLER BR2B OR APPROVED EQUAL. TAPPING SLEEVE SHALL BE BRASS OR BRONZE FOR "CC" THREADS, FORD S-70, MUELLER H-134, JCM 403 OR APPROVED EQUAL FOR SDR -21 PVC. CLASS 20 POLYETHYLENE CORPORATION STOP SHALL BRONZE WITH "CC" THREADS, MUELLER B-25000, FORD F6600, JCM 403 OR APPROVED EQUAL DUCTILE IRON PIPE P.V.C. PIPE (CLASS 50 CEMENT LINED) (CLASS 200) NOTE: ALL TAPS TO BE MADE ON TOP QUARTER OF MAIN. STANDARD WATER TAP DETAIL NOT TO SCALE Name Date Drawn By: PAGE Checked By: JOFNSTON COUNTY WATER Approved By: Department of Public Utilities STANDARD DETAIL 19 Scale: P.O. Box 2263 Standard Water Tap Smithfield, NC 27577 of 47 Rev.1 Description IDatr,. Ilnit. Behold, a virgin shall be with child, and shall bring forth a son, and they shall call his name Emmanuel, which being interpreted is, God with us. Matthew 1:23 CONCRETE THRUST BLOCK AT 45' BEND. �;. SEE THRUST BLOCK DETAIL FOR DIMENSIONS OF BLOCK. 10' MAX. NOTE: ALL PIPE SEGMENTS LESS X" S.S. THREADED RODS THAN 10' SHALL REQUIRE J CCON�CORETDR408ST BLOCK SEE THRUST BLOCK DETAIL FOR DIMENSIONS OF BLOCK. ROD REQUIREMENTS SIZE OF 45' BEND STATIC THRUST IN POUNDS NUMBER OF RODS REQUIRED 6" 4,328 2 B. 7,694 2 12" 17,312 2 16" 30,779 4 20" 48,091 6 24" 69,252 8 GENERAL NOTES 1. RODS AND NUTS SHALL BE OF TYPE 304 OR TYPE 316 STAINLESS STEEL. 2. CONCRETE SHALL NOT CONTACT BOLTS OR ENDS OF MECHANICAL JOINT BENDS. VERTICAL BEND RODDING AND BLOCKING DETAIL NOT TO SCALE JOHNSTON COUNTY Department of Public Utilities P.O. Box 2263 Smithfield, NC 27577 WATER PAGE STANDARD DETAIL Critical Bend Rodding and Blocking Details of 47 #3 REBAR 10" 2 EA. i-2" M ° 4» Ff 24" NOTE: PROTECTOR RING SHALL BE 3,000 P.S.I. CONCRETE. CONCRETE PROTECTOR RING NOT TO SCALE JOHNSTON COUNTY Department of Public Utilities P.O. Box 2263 Smithfield, NC 27577 PAGE WATER STANDARD DETAIL 14 Concrete Protector Ring of 47 LID SHALL BE LABELED "WATER METER" AND SHALL BE "AMR" TYPE WITH METAL FLIP -UP LID AND 2" HOLE FINISHED GRADE METER (US GAL.) 99„X-4" 7" MIN' II- 13" MIN. CLEARANCE MIN. 4" WASHED STONE 2LOCK TYPE 0" MIN. METER CL STOP ANGLE CHECK BLOCK SUPPORT OR VALVE STONE AS NEEDED 7" 74" OR 1" CLASS 200 • POLYETHYLENE WATER SERVICE LINE WIDE BODY OR DOUBLE STRAP SADDLE METER YOKE SHALL BE COPPERSETTER MUELLER NO. H-1404-2, FORD NO. VH -72-7W OR APPROVED EQUAL FOR METER YOKE COMPLETE WITH �4" SERVICE DUAL PURPOSE FITTINGS CORP. STOP WATER MAIN U -QM. 1. CONTRACTOR SHALL PLACE METER BOX IN NON TRAFFIC AREA ONLY. 2. PLASTIC METER BOX SHALL BE CENTURY #1015, NDS D1200, OR APPROVED EQUAL 3. CONTRACTOR SHALL CENTER METER YOKE IN METER BOX. 4. METER YOKE TO MUELLER No. H-1404-2, FORD No. VH -72-7W OR APPROVED EQUAL. 5. METER TO MEET AWWA C-700-71 STDS. AND SPECS. 3/4" & 1" WATER METER SERVICE DETAIL 7;_0 NOT TO SCALE xl Name Date JOHNSTON COUNTY Department of Public Utilities P.O. Box 2263 Smithfield, NC 27577 WATER STANDARD DETAIL X" and 1" Water Meter Service PAGE 20 L of 47 Drawn By: Checked By: Approved By: Scale: N Rey.1 Description jDate Init. BLN=C-1874 X� a CA /gyp`'' R• Q� SEAL � = 19843 EL • ,, �I�IQI 111 �/� 2/1/19 AQUA WATER DETAILS REVISIONS FILE NO. 2018-033 HORZ. SCALE: AS NOTED VERT. SCALE: NONE 00(0 Orn 7;_0 xl O L0 M O^ N N W Z O O d Z_ E W W Z_ 0 Z W Z (n Y O O WF W W WV) (n Z OJ O LQ • Z N = U (n Z Z ~W J W 0 I= = U) Oa DQ z BLN=C-1874 X� a CA /gyp`'' R• Q� SEAL � = 19843 EL • ,, �I�IQI 111 �/� 2/1/19 AQUA WATER DETAILS REVISIONS FILE NO. 2018-033 HORZ. SCALE: AS NOTED VERT. SCALE: NONE i II I 0 I II II ,•N •. 0 z Of 12' 1 12yI12 ' •$ ' I Q I� I Ld Z z cn I :`• II + I I II •� I o 0 li W i I FW J z z� o� • I ,� I �► 201 I � 2'R I �z ZF- I� I 4" MINI -SKIP ACm (THERMO) +10 \ !RR 03 ______-- 1 ----------- �� \\ 1\ II I 22 1 \'I +IID z I 90 Rlw _ _ ' 22 22' �-I PROPOSED 5, \\\ \\; \\\ 36, SIDEWALK I \ \ \ - \ ' 22 H. C. SIGN >' \\ \� \\- g- 36 (VAN ACESS) 1 r 1 \ �EGIN LOWER WATERLINE TO AVOID CONFLICT -2 I \ \ i 36 H. C. SIGN 24 MEDIAN CURB ELEV. 280.00 I 2 ,� 36' 2 H. C. SIGN (VAN ACESS) 1, DIRECTIONAL ARROW ? 1, 22 (VAN ACESS) THERMO TYPICAL 2 0 / OM \ \ \ r ( ) (TYPICAL) '\ TION FR ,,-- IL FIRE / 24 WIDE ----__ '� - NSI \\ r >••i 80 LF 6" SDR 35 TRA DER CNRg to ->_-- �` \ \} HYD i STOP BAR �- \\ \ \ \ I P VC S. S. @ 2.08% THERMO \ \ \ \ \ \ \ \ \ \ --_HEA -_-& C I \\ \ o \ I :'•;;.:,� C. O. TOP ±292.00 �' ' H. C. SIGN \\\ \\\\ \`\ \ — \\� \\`Ss;Q INV. 282.51 I \\ r TOP �� \ I WCR 2 WA TER/ GN \ \ \ STOP SER VICE _ _ _ _ _ ' / \ \ — -- .1 \h \\ \ \\ \\ SIGN - - - - M ----� _\--- A \ r ------ - ___----- DER IA. ---- \ o ---___ N R M HE - _ _ e•V .�a• ` I \ \ I ".. 4- � 24" STD � TRANSITIO " C&'C 0 C&�G CNRg to 3 e WCR ------_____ �! �a TIL. iI�I'T I FIRE C- EAS900 p VC I � BEHIND WA TER I i HYD TR SIDEWALKS 11 I _ rr \ \ o\. a' ANSI TION ,�ROil�1 II ' TER I I 3o ,, 1 WA o+ I , C&G TO 24"STD. S STD. I i , 2 / ` \\ \ Y \ i , \ \ TD. CdcG II ,SER VICE - - - -'� \ \ o \\ cin I \ \ I s0 \ II FOCI- , -o \ AN \ t 4 SOLID s \ x - v _ _ _ /Y \ WHITE STRIPE ��c \\ d \\ `�\�' , ,Q_Q a \ _ SEE SH ETD 0 (THERMO) _ _ \ \ \ I \, � •::�-.::.� \ • og\ 1 a. \\ \_ ' UTILIT 20 Y FOR R� _ EAR -OFF STCD \ \\ r \\ Ilk \ EASEM _ N _ \\ UTILITY BLOW- (2) 1; 250 GALN, FIRELINE. 4 „ WASTE ' \ ` \ o \ J o GREASE T?AP INV. OUT 286.50 \\ \ \ 4 MINI -SKIP \\ 00 Q �� Q, \ \\ \ & DOMESTIC TOP ±288.Oi9\ 4 S. S. 1 (THERMO) RETAINING WALL \ �� `�\\\ `i BACKFLOW /N V. IN 285.67 \ \ \ \ \ \ \ \ \ h NCDOT �, I INSIDE BUILDING \\\ - TRANSITION FROM \ \\ \, o `� \\ (SEE DETAIL) \ �0 �� STANDARD �• , l INV. OUT 285.50 •. HEADER CURB to \ \. o \ M.H. 8 '& I / , , , , 4 GREA S \ \ \. . '� •. ~..e o \ I \ \ \ \ \ '` \ GAURDRAIL i n \ \ \ \ \TOP +291.00 �, I WASTE 4 30 C&G \ \ \ i \ \ \ � • � \ i � FIRE a o � M. H. 4 -\ HYD \ ' FIRE INV. OUT WASTE # \ N \ \ INV OUT OUT 281.10 \\ -_, � a I r , \ \ \ - _ _ 'I ', LINE 286.50 I -TOP +291.50 , , \ \ \ 20 LF DRY BORE :,4 \ I INV'-il� 278.82 \ STOP \\ \ \\ AND JACK W/18"�% ���L INV. OUT\2-7C. 8 \\ SIGN__--- \\\ ENCASEMENT &M. H. #6 STOP-- 8" DIP CARRIER \ �? �,� \\`�_ _ - 2 1-�, . o �� __--- \ SIGN \ TOP +282.00 \ \ _ _ �2 0 0. _ _ - _ o, PIPE. INV. IN 275.85 \\ �,\ - ;-- o C' _ \_1 __ __-- \\---________ \\ _���; '� \� ""\ \ \ WATER \\ ` `\ \ \ G N INV. OUT 275.65 `\ aa.\ __----- \ \ �''' �� 20 0\ \ \ �: \ — , \\ �� `` \\ \\�� RETAINING W%LL \\\ °'��-��--------- -_ _ ,----- TER __----_ ^\ \\ \\ SR"-� ` FIRE (SEE DETAIL) \\\\!��-�- \\ _ C_90��VC_WASQ)• \,\ \vr HYD / 0 20-51R \\ \ \ \ O\\�` \\ \\ \ 8 __—_-- �- \\ \ \ -�- \ \ \ \�` cA \ / ,� \ TOP +278.35 / 5 �' 00 , • \ INV. IN 269.03 (#4) ' 1 �O. \\ \n m INV. IN 267.23 5 / �' 4- \ (`) 40 R \ \T\ \ \ \ � \ •:�:� � \ � ' I � INV. OUT 267.0� r \ \ \ 46 LF 8 CL 50 C -o/ /' \\ \ m ��ii \ ?Og �, � STOP / \ \ \ \ s Zi \ DIP SIGN .lool 280--- EXISTING 80- EXISTING WETLANDS Vol - STREAM TO REMAIN (DO NOT DISTURB)\\ \\\ \\ (01 „;� \\ _XPi"0 Oro\\ �� k \ 285 -----_____\ \\ GSR �;,\� Fps a \ \ \ \ \ \ \ \\ \\ / M. H. #5 Am G \ SCALE: 1 " = 30' 0 30 100 125 150 AND THE ANGEL SAID TO THEM, "FEAR NOT: FOR BEHOLD, I BRING YOU GOOD TIDINGS OF GREAT JOY, WHICH SHALL BE TO ALL PEOPLE. I FOR UNTO YOU IS BORN THIS DAY IN THE CITY OF DAVID A SAVIOR, WHO IS CHRIST THE LORD. LUKE 2: 10-11 �00 x1 0 m `O V O '04 N w z 0 `1 HORZ. SCALE: 1"=30' 0 N/A U 0 z Of w w z Ld Z z w cnY U 0 W o� FW z z� o� • z N M = U �z ZF- w J W 0 w> 00Z BLN=C-1874 ��` , CA Rod "'', ES`04; "k Q SEAL l 19843 '�,`� '•.FNG I NES-E�.•G`��``: /CHAEL S'LI� z/i /i s REAR OF STORE UTILITY BLOW-UP REVISIONS FILE NO. 2018-033 HORZ. SCALE: 1"=30' VERT. SCALE: N/A D-05 ASp17dfPdVh7g 1. The Contractor or Subcontractorperforming the paving operation will be responsible forperforming the fol%wing"" A. Sufface Tolerance Surface tolerance requirements for smoothness must be checked in the presence of an Inspector using a 'Roll/ng Straightedge " for checking surface tolerance. A variation of more than 1/8"in 10 feet will be considered unacceptable and must be corrected /n an acceptable manner which will also meet Item (B and H) below" B. Surface Texture Care sha//be taken to insure that smooth dense texture /s achieved with no se re ation tearin crackin etc. Areas discovered which are not uniform in appearance and 9 9 g g PP texture shall be reheated and rero/%d, rep/aced, or ifrequired by the Eng/neer, resurfaced at no additional cost to the Owner Seams and edges shall be straight, true, and smooth. C" Plant Tickets To verify depth for payment, plant tickets shall be submitted to the Engineer D. Payment ofAspha/t No payment for paving will be made until the surface texture and smoothness has been inspected, satisfactonly repaired, ffnecessary, and approved by the Engineer and the Owner. E Paving Subcontractors The Genera/ Contractor fn charge of the Paving Contractor sha//be responsible forassurfng that his paving Contractor has read these requirements ffpaOng fs to be subcontracted. Faf/ure to Inform a Subcontractor does notrelfeve the Prime Contractor of these requirements" F" Paving Condition No paving of asphalt shall take place until the Utf/fty Contractor and the Paving Contractor have mutually agreed that a// valve boxes and manholes have been set to finished grade and that It fs the Paving Contractor's responsfbf/fty to make minor adjustments prior to paving, as app/fcab/e. G. Asphalt Specifications Asphalt and CABC shall meet the NCDOT "Standard Specifications for Roads and Structures" latest revision. Asphalt mix and placement shall meet Division 6 ofthe State Specffrcatfons. CABC shall meet Section 520 of the State Specifications andgraded fn accordance with Table 520-1. Placement and compaction shall meet Section 520. H" Asphalt Patching Asphalt Patching WILL NOT BEALL OWED. /n the a vent that Asphalt is unsatisfactory to Engineer, the contractor shall mill entire section of asphalt and resurface a minimum depth of one and one-ha/finch and at minimum length of one hundred feet for the entire width ofsectfon fn question" This area fs to be determined by fie/d Inspection with the contractor and/or sub contractor and the Engfneerpresent" 2" Al/ aspha/t prices fn this proposal shall be based on the NCDOT Monthly Terminal F" 0 " at time of bid. IF the asphalt cement price fluctuates from this stated price more than 10% at any time during the performance of the asphalt scope, the contractor will adjust the asphalt prices fn accordance with the new/ypub/fished NCDOT Monthly Termfna/ F. O B. Aspha/t Binder Prices. These prices are located at the following web address." <htips://connect"ncdot"gov/projects/construction/Lists/Month/y%20 Terminal%2OAspha/t%2OBinder'O20%2OFue/%2OFOB%2OPrices/A///tems.aspx> Drainage Notes 1. Boxes may be reinforced masonry, masonry, precast concrete or cast In place reinforced concrete. 2" The maximum height ofan un -reinforced masonrydrainage structure with 8 -Inch walls sha//be limited to 8 -foot from Invert ofthe out/et pipe to the top ofthe casting" Depths greater than 8 -feet sha//have walls 12 Inches thick" Basins over 12 -feet fn total depth sha//be designed bya NC Professional Engineer" Four -inch walls are not a//owed on drainage structures. 3. Steps are to be provided on all basins deeper than 42' 4. Steps are to be PS 1 -PF as manufactured by M. A. Industries or an approved equal" Locate on non pipe walls" 5. Mortar In masonry boxes fs to be type M" 6. Clay brick structures are not a//owed. 7. Concrete building brick is to meet ASTM C-55, Grade N, and Type 1. 8. All Iron castings are to be drilled and lagged to the drainage structure. The drainage structure as we// is lobe drilled 9. All cast-fnp/ace or precast concrete drainage structures located in paved areas accessible to truck loadings to be designed to meetAASHTO HS 20-44 loading" See manufacturers detaf/s for wall, top and bottom thickness. 10. All catch basins grates and frames are to be Vu/can or approved equal. Verify dimensions heights on castings are not exceeded in critical areas before ordering castings! 11. All concrete pipe is to be ASTM C-76, Class /ll with ram nek" 12" All castings to receive Bituminous Coating Grading Notes 1. Site Contractor to inform Building Contractor to verify frnishedgrade at building before digging footings. Some portions of the building foundation wall may, of necessity, need to retain buf/dfng pad All to a//ow extenorgrades to be dropped" /n this case, step footIngs maybe necessary to achfe ve the desired grade variations" 2" New finished contours shown are top of future paving fn areas to receive pavement and top oftoosof/In areas to be seeded" 3. Areas outside of the parking lot perimeters shall receive 4 inches of topsoil" This topsoil to be placed and leveled by the Contractor 4" Dfinens/ons on bu/ld/ngs are forgradfng purposes only and are not to be used to /ay -off footings" See Architectura/ Plans" 5. Contractor shall notify and cooperate with a// ut/lfty companies or Arms having faclI ies on or adjacent to the site before disturbing, a/tering, removing, relocating, adjusting or connecting to said facf/itfes" Contractor shall raise or lower tops of existing manholes, as requ/red, to match Anfshedgrades" 6" Al/ catch basin grate and frames are to be Vu/can or approved equal" Verify that d/mensfon heights on castings are not exceeded In critical areas before ordering substitute castings! 7" Al/ areas not covered by building orpaving are to be seeded and mulched. 8. Unusable excavatedmateria/s and a// waste resulting from clearing and grubbing and demo/Rion sha//be disposed of off-site by Contractor" 9 Al/ exca vatfon fs unclassified and shall Include a// materials encountered. 10. Before any machine work Is done, Contractor shall stake out and mark the Items established by the Sfte Plan" Control points shall be preserved at a// times during the course ofthe project. Lack ofproper working points and grade stakes may requ/re cessation ofoperat/ons until such points and grades have been placed to the Owners satisfaction" 11. Contractor to ensure a//portions of the site have positive drainage. This must be verified prior to paving orpouning concrete. 12. Refer to sof/s report for directions on earthwork and subgrade preparation, Ifavaflable. Concrete Testing Requirements Initial Test The Inftfa/ test (from Arst ready -mix truck) Is to be taken after the second yard Is dispatched from the mixer and Is to consist of the following"" 1. One slump test 2" Pu/l, prepare and store 3 cylinders on-site for 24 hours" 3" Temperature Subsequent Tests After the above tests are pulled from the initial truck, every 5th truck thereafter Is to be tested fn the same manner as noted above. Asphalt Testing Requirements Compaction : Testing for asphalt density Is to follow NCDOT "Standard Specifications for Roads and Structures", Section 6099, 'Field Compaction Quality Management, "latest revision. Thickness : The minimum frequency of coring for thickness testing shall be on the basis of test sections consisting of not more than 1500 linear feet of lay down width, exc/usfve ofintersectfons and Irregular areas. The test sample fs to be a 6 -Inch cored samp/e. The sample IS to be numbered and logged for identification purposes. Contractors Quality Control System Follow NCDOT "Standard Specifications for Roads and Structures" Section 609-5, "Contractors Quality Control System, "latest revision: Mixture and Job Mix Formula Adjustments Follow NCDOT 'Standard SpecfAcatfons for Roads and Structures" Section 609-4. 'Field Verification ofMfxture and Job Mfx Formula Adjustments" latest revision. Genera/: A// other app/fcab/e sections of Section 609 of the NCOOT "Standard SpeciAcations for Roads and Structures " shall apply relating to Quality Contra/ Plan, mix design, control limits, corrective action, equipment and measurement. Testing Cost: Contractor is responsible for cost of testing asphalt and concrete. Parking►, Street or BuildingSubgrade Preparation A. Subgrade on Precomoacted Original Soil 1" Remove all the topsoil and all questionable organic soil and extend a min/mum of four (4) feet beyond the outside edge of the pavement. 2" Precomoact the exposed grade with a vibratory roller weighing a min/mum often (10) tons (static load) or equal to stabilize the Initial settlement ofthe top strata ofthe soil" The stability ofthe subgrade will be considered adequate when the total settlement after the last four (4) complete passes by the vibratory ro/%r does not exceed 1/8" Any area that sett/es excessively and falls to stabilize under continued rolling should be further undercut and rep/aced with properly compacted select granular All B. Subgrade on Certified Compacted Fill 1. Prepare the site follow/ng the same procedures as outfined /n Items 1 and 2 above. t - -" Z" Usingthe same compaction equipment as outlined above compact newAll m /8 inch layers to a minimum 98 -percent of maximum d density at o timum moisture content in accordance with the Standard Proctor Method p� p Y p dry t1' p ASTM Standard D 698-78 and field control%din accordance with ASTM Standard D 2167-84, or equal" The top one (1) foot of the prepared All subgrade should be compacted to 100 percent of the maximum dry density using the Standard Proctor Method" 3" The end of the All should be terminated at the minimum slope of two (2) horizontal to one (1) vertical measured from three (3) feet beyond the outside edge of the pavement to the toe of the fill" The All soil is to be selectgranu/ar soil weighing a minimum of 110 pcfat its optimum moisture content" Concrete Notes 1. Al/ construction, placing, pouring and curing concrete is to conform to the latest edition ofACl 318. 2" Al/ reinforcing steel Is to be cold cut and bent. 3. Port/and cement concrete shall have a minimum 28 day compressive strength of 4, 000 PS/" 4" Do not use chloride fn any concrete which has reinforcing steel or wire fabric" 5. Reinforcing stee/sha//meetASTMA-615, Grade 60" Welded wire fabric sha//meetASTMA-185" Tfe wire shall conform toASTMA-82" 6. Lap welded wire fabric a minimum of one mesh. Lap all bars a minimum of24" Altemate adjacent barsp/ices a minimum of 48' 7" Use only approved chairs with sand plates to support reinforcing on grade. 8. Al/ crossings of reinforcement are to be tied" Supports for reinforcing to hold bars against movement during pour and finish operation. Supports for reinforcing bars to be a minimum of 48 inches apart. 9. Concrete shallbe onlyplant-mixed, transit -mixed or ready -mixed concrete. The time elapsing from mixing to placing the concrete shall not exceed ninety (90) minutes. 10" Concrete shall not be deposited on frozen subgrade and shall not be poured when the air temperature for the succeeding 24 hour period fs less than 32 degrees F. 11. A// concrete when placed informs shall have a temperature between 50 degrees F and 90 degrees Fand shall be maintained at a temperature of not less than 50 degrees for at /east 72 hours for norma/ concrete and 24 hours for high early strength concrete. 12. Do notplace fresh concrete during summer on a dry subgrade. Moisten subgrade before p/acfng concrete. 13" Subgrade Is to be firm, free of water and/or sf/t and undisturbed or compacted proper/y" Consult Engineer IF soft oryie/ding subgrade is encountered for improvement directions. /(ground water is entering subgrade, consult Engineer for instructions. 14" Areas of concrete to be removed shall be saw cut before removing" The saw cut sha//provide a smooth, straight edge approximately two (2) Inches deep before breaking away the adjacent concrete" 15" Immediately after the forms have been removed and a// honeycombed areas are repaired, backfill to prevent underwash" 16" Brooming of the concrete surface sha//be done transverse to the direction of traffic for areas" 17" Joint spacing sha// be no less than 8 -feet" Where existing sidewalks are being widened, transverse joints sha// be located so as to /fine up with existing joints in the adjacent existing sidewalk Grooved joints shall not be sea/ed. Sea/ a// others" 18" Concrete Sub shall be responsible for a// score joints and expansion joints" A pre/fminaryscore joint pattern and expansion joint pattern shallbe submitted to the project engineer for review prior to pouring concrete. 19" Expansion joints shall be one-half (1/2) Inch fn width and shall be placed between a// rigid objects at a distance of no more than thirty (30) feet apart and shall extend the full depth of the concrete with the top of the filler one-half (1/2) Inch below the finished sun`ace" 20" The edges of the curb/sfdewa/k shall be finished with an approved edging too/ one-half (1/2) Inch radius" Joints shall be similarly finished immediately after templates have been removed" 21. Saw contra/joints as soon as fresh concrete wfl/retain coarse aggregate against the sawing action. 22. Contractor SHALL NOT POUR any concrete before forms are Inspected by the project engineer and/or the architect Any concrete that has not been approved by the engineer and/or owner will be the responsibility of the contractor. GOSPEL NOTES: The following notes do not represent the belief of any municipality, government organization, or client of Stocks Engineering. The detail is included to show the foundation of Stocks Engineering and its employees. Our prayer is that through the truth outlined below you will clearly see what it means to have a personal relationship with Christ. 1. GOD'S LOVE God loves you and he created you to know him personally. He has a wonderful plan for your life. John 3:16 "For God so loved the world that he have his only son, that whoever believes in him shall not perish but have eternal life." What prevents us from knowing God personally? 2. OUR CONDITION People are sinful and separated from God, so we cannot know him personally and experience his love and plan. Romans 3:23 "For all have - -III This diagram illustrates that God sinned and fall short of the is Holy and people are sinful. A glory of God." great gulf separates the two. The Romans 6:23 "For the wages arrows illustrate people continually of sin is death" (Spiritual _ trying to reach God through our separation from God) -I I - - own efforts, but we inevitably fail. There is only on way to bridge this gulf... 3. GODS RESPONSE Jesus Christ is God's only provision for sin, through Him alone we can know God personally and experience his love and plan. Romans 5:8 "But God dem- onstrated His own love for us in this: While we were still sinners, Christ died for us. John 14:6 Jesus answered, 'I AM the way the Truth and the Life. No one comes to the Father except through me'. GOD PEOPLE This diagram illustrates that God has bridged the gulf that sepa- rates us from Him by sending His son, Jesus Christ, to die on the cross in our place to pay the penalty for our sins. It is not enough just to know these truths... 4. OUR RESPONSE We must individually receive Jesus Christ as Savior and Lord; only then can we know God personally and experience His love and plan. Ephesians 2:8-9 "For it is by grace you have been saved, through faith - and this is not from yourselves, it is the gift of God - not by works, so no one can boast." John 1:12 "Yet to all who received Him, to those who boast." These two circles represent two kinds of lives... SELF4SELF Self -Directed Life Christ -Directed Life Self is in the center Christ is in the center and on the throne; and on the throne; Christ is outside. self yields to Christ. Which circle best represents your life? Which circle would you like to have represent your life? You can receive Christ right now by faith in prayer. "Lord Jesus, I need you. Thank you for dying on the cross for my sins. I open the door to my life and receive you as my Savior and Lord. Thank you for forgiving my sins and giving me eternal life. Take control of the throne of my life. Make me the kind of person you want me to be." If this prayer expresses the desire of your heart, then you can pray this prayer and Christ will come into your life as he promised. For more information on what it means to have a relationship with God, or if you have any questions or prayer requests please submit them to stocksengin eering@gmail.com, call us at 252.459.8196, or visit our web site, www.stocksengineering.com Behold, a virgin shall be with child, and shall bring forth a son, and they shall call his name Emmanuel, which being interpreted is, God with us. Matthew 1:23 BEFORE YOU DIG, CALL 0 ;7,, - NORTH CAROLINA &NE CALL CENTER www.ncocc.org 00(0 o0) �;_0 xl o mLO o� . N 0 u7 N Q Z W~ w w WV) Zz(.0 0 L �00 � Z N U < Z �z Lei J W<' () w= o< 00 Z 0 U 0 Z w w Z 0 Z w Cn Y U 0 ,� �,a•EssR• i -, SEAL 19843 '91A EL c) '/2' cJ 2/1lei9 COVER SHEET REVISIONS FILE NO. 2018-033 HORZ. SCALE: NONE VERT. SCALE: I NONE Operation & Maintenance Agreement Project Name: Project Location: Publix Flowers Plantation Maintenance records shall be kept on the following BMP(s). This maintenance record shall be kept in a log in a known set location. Any deficient BMP elements noted in the inspection will be corrected, repaired, or replaced immediately. These deficiencies can affect the integrity of structures, safety of the public, and the pollutant removal efficiency of the BMP(s). The BIVIP(s) on this project include (check all that apply & ce Bioretention Cell Quantity: Dry Detention Basin Grassed Swale Green Roof Infiltration Basin Infiltration Trench Level SpreaderNFS Permeable Pavement Proprietary System Rainwater Harvesting Sand Filter Stormwater Wetland Wet Detention Basin Disconnected Impervious Area User Defined BMP Quantity: Quantity: Quantity: Quantity: Quantity: Quantity: Quantity.- Quantity: uantity:Quantity: Quantity: Quantity: Quantity: Quantity: Present: Present: ng O&M tables wii Location(s): Location(s): Location(s): Location(s).- Location(s): ocation(s):Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): ne aaaea autom I Below Lot #7 1 I acknowledge and agree by my signature below that I am responsible for the performance of the maintenance procedures listed for each BMP above, and attached O&M tables. I agree to notify NCDENR of any problems with the system or prior to any changes to the system or responsible party. * Responsible Party: Title & Organization: Street address: City, state, zip: Phone number(s): Email:l Signature: Rebecca Flowers President, DWF Development 4880 NC Hwy. 42 East Clayon, NC 27527 919.369.8332 reid@flowersplantation.com , a Notary Public for the State of Date: (91-3 11.ioeTu GadcoL, N � County of `F.�J�SH do hearby certify that personally appeared before me this 304!-- day of -' p,gyoAv and acknowledge the due execution of the Operatio s and Mail -len enc Agreement . Witness my hand and official seal, N STOW �Y �11R `FAQ 61-*ee ST 1/15/2019 Version 1.4 O&M Manual Pagel of 5 The wet detention basin system is defined as the wet detention basin, pretreatment including forebays and the vegetated filter if one is provided. Important maintenance procedures: Immediately after the wet detention basin is established, the plants on the vegetated shelf and perimeter of the basin should be watered twice weekly if needed, until the plants become established (commonly six weeks). No portion of the wet detention pond should be fertilized after the first initial fertilization that is required to establish the plants on the vegetated shelf. Stable groundcover should be maintained in the drainage area to reduce the sediment load to the wet detention basin. If the basin must be drained for an emergency or to perform maintenance, the flushing of sediment through the emergency drain should be minimized to the maximum extent practical. Once a year, a dam safety expert should inspect the embankment. After the wet detention pond is established, it should be inspected once a month and within 24 hours after every storm event greater than 1.0 inches (or 1.5 inches if in a Coastal County). Records of operation and maintenance should be kept in a known set location and must be available upon request. Inspection activities shall be performed as follows. Any problems that are found shall be repaired immediately. BMP element: Potential problem: How I will remediate the problem: The entire BMP Trash/debris is present. Remove the trash/debris. The perimeter of the BMP Areas of bare soil and/or Regrade the soil if necessary to remove the gully, and then plant a erosive gullies have formed. ground cover and water until it is established. Provide lime and a one- time fertilizer application. Vegetation is too short or too Maintain vegetation at a height of approximately six inches. long. The inlet device The pipe is clogged. Unclog the pipe. Dispose of the sediment off-site. The pipe is cracked or Replace the pipe. otherwise damaged. Erosion is occurring in the Regrade the swale if necessary to smooth it over and provide erosion swale. control devices such as reinforced turf matting or riprap to avoid future problems with erosion. Stone verge is clogged or Remove sediment and replace with clean stone. covered in sediment (if applicable). The forebay Sediment has accumulated to Search for the source of the sediment and remedy the problem if a depth greater than the possible. Remove the sediment and dispose of it in a location where it original design depth for will not cause impacts to streams or the BMP. sediment storage. Erosion has occurred. Provide additional erosion protection such as reinforced turf matting or riprap if needed to prevent future erosion problems, Weeds are present. Remove the weeds, preferably by hand. If pesticide is used, wipe it on the plants rather than spraying. The vegetated shelf Best professional practices Prune according to best professional practices show that pruning is needed to maintain optimal plant health. Plants are dead, diseased or Determine the source of the problem: soils, hydrology, disease, etc. dying. Remedy the problem and replace plants. Provide a one-time fertilizer application to establish the ground cover if a soil test indicates it is necessary. Weeds are present. Remove the weeds, preferably by hand. If pesticide is used, wipe it on the plants rather than spraying. STORM -EZ 1/15/2019 ,/ersion 1.4 O&M Manual Page 3 of 6 The main treatment area Sediment has accumulated to Search for the source of the sediment and remedy the problem if a depth greater than the possible. Remove the sediment and dispose of it in a location where it original design sediment will not cause impacts to streams or the BMP. storage depth. Algal growth covers over 50% Consult a professional to remove and control the algal growth. of the area. Cattails, phragmites or other Remove the plants by wiping them with pesticide (do not spray). invasive plants cover 50% of the basin surface. The embankment Shrubs have started to grow Remove shrubs immediately. on the embankment. Evidence of muskrat or Use traps to remove muskrats and consult a professional to remove beaver activity is present. beavers. A tree has started to grow on Consult a dam safety specialist to remove the tree. the embankment. An annual inspection by an Make all needed repairs. appropriate professional shows that the embankment needs repair. (if applicable) The outlet device Clogging has occurred. Clean out the outlet device. Dispose of the sediment off-site. The outlet device is damaged Repair or replace the outlet device. The receiving water Erosion or other signs of Contact the local NC Department of Environment and Natural damage have occurred at the Resources Regional Office. outlet. The measuring device used to determine the sediment elevation shall be such that it will give an accurate depth reading and not readily penetrate into accumulated sediments. STORM -EZ 1/15/2019 Jersion 1.4 O&M Manual Page 4 of 5 Wei Detention Pond Design Summary Wet Pond Diaararn STORM -EZ 1/15/2019 Version 1.4 O&M Manual Page 5 of 5 WET POND ID FOREBAY MAIN POND NA Permanent Pool EI. 262 Permanent Pool El. 262 Temporary Pool EI: 264.7 Temporary Pool EI: 264.7 Pretreatment other No Clean Out Depth: 6 Clean Out Depth: 3 than forebay? Sediment Removal El: 256 Sediment Removal EI: 259 Has Vag. Filter? No Bottom Elevation: 254 Bottom Elevation: 257 STORM -EZ 1/15/2019 Version 1.4 O&M Manual Page 5 of 5 at Flowers Plantation 4684 NC Hwy 42 Clayton, NC 27527 919-553-3084 FLOWERS PLANTATION W I K*-� �- 4 ENGINEERING 801 EAST WASHINGTON STREET P.O. BOX 1108 NASHVILLE, N.C. 27856 PHONE: (252) 459-8196 WWW. STOCKSENGIN EERI NG. COMI CARl^,! ,,�* �� Q r•ss°Qae���+gyp}/+// ' SEAL r 19343 . &A E � g WET DETENTION FOREBAY VOLUME COMPARISON FOREBAY VOLUME ELEVATION SURFACE INCREMENTAL AREA VOLUME 252 0 250 0 0.0 253 0 251 0 261.5 254 523 252 0 723.0 255 923 253 0 1,176.5 256 1430 254 0 1,735.5 257.0 2,041.0 255 0 2,399.5 258.0 2,758.0 256 0 3,169.0 259.0 3,580.0 257.0 18,187.0 4,026.5 260.0 4,473.0 258.0 19,346.0 2,484.8 261.0 5,466.0 259.0 20,530.0 SUM = 15,976.3 Forebay is 16.6% of Pond. Pond Average Depth: 3.0 Feet POND VOLUME ELEVATION SURFACE INCREMENTAL AREA VOLUME 250 0 0.0 251 0 0.0 252 0 0.0 253 0 0.0 254 0 0.0 255 0 0 0.0 256 0 9,093.5 257.0 18,187.0 18,766.5 258.0 19,346.0 19,938.0 259.0 20,530.0 21,134.5 260.0 21,739.0 11,178.0 261.0 22,973.0 SUM = 80,110.5 3.0094 X- Gv2ut Nk�,ngit2 P;ZE - DC�c��oPnrL�NT w00pZ50 tm9C-(ZUtQ-s ItkS.N9AC- P05T-►`�-Evc'LaP 67PLT Inl.tio p-�,rvD i r� 9 Cr2Y is �S Glass E° Zcl aypAsS °to 1n.3 sAL C�=�b kZ-31-t r-LaL4v" kJdw #J = l tilts �Utck.SS r42.r �4 F�r2-cM� E�vig� k A,.�1� L -OT t 815 S,, (^A?rr-eu i dss = s3� &,at sr = I. L3 + L.v'TZ %s,. ♦P-tPaca,w►s= 44,9oZsr-d LOQ' 1 as 5v ~QeQ ,A4,.js _ 33, 3Z3 SF d L -,*T S : 85-- X CA^4;1 R ,sus r `ft/ $4105c : 2.. 27 UT 2, rte s = 2'73, X0`58 SF o • Za To A -L, r I�e�Pci?_ur o,.s s = 16t. 7o A c.(S5% s4 co sr-) '�-ai�A-L t�2A-i SCA -cry = qo : Q q- 44C -7 *41 Zq7 Sr_ 'F- F2av`1 '54/1>4 = 1•79 sir = C. 7q % /ov ) -- 1,7'f�1, Z"-'} 7 s F s 4-= 3! , 223 sF Vo��q Cwt S„ S P -V -=!6.05 fn.cj -� sq►�...� ��e a.�9 = o .c -s -f- c-,. 9 4- 0.49 - n. qq G4-30 4- O -o -v 12v � A 3, (036 -#- 1 -4 6.49 -64 c0, Ac "' `7/��191F cr-s �ll � v9 CF I o- s 4 c.FS C..o A-r4h1C��,� t Watershed Model Schematic Hydraf low Hydrographs Extension for AutoCADO Civil 3D@2018 by Autodesk, Inc. v12 CD CD Project: Pre vs Post.gpw Monday, 12 / 31 / 2018 Hydrograph Return Period Rec�a�� y low Hydrographs Extension for AutoCAD® Civil 3D® 2018 by Autodesk, Inc. v12 Hyd. Hydrograph Inflow Peak Outflow (cfs) Hydrograph No. type hyd(s) Description (origin) 1 -yr 2 -yr 3 -yr 5 -yr 10 -yr 25 -yr 50 -yr 100 -yr 1 SCS Runoff ------ 48.87 75.60 ------- ------- 152.24 201.49 ------- ------- Pre Development 2 SCS Runoff ------ 8.156 14.00 ------- ------- 31.51 42.92 ------- ------- Post Bypass 3 SCS Runoff ------ 75.65 105.03 ------- ------- 183.71 231.09 ------- ------- Post into Pond 4 Reservoir 3 7.390 20.61 ------- ------- 126.50 187.18 ------- ------- Wet Pond Proj. file: Pre vs Post.gpw Monday, 12 / 31 / 2018 Hydrograph Summary Report Hydraf low Hydrographs Extension for AutoCAD® Civil 3D® 2018 by Autodesk, Inc. v12 Hyd. No. Hydrograph type (origin) Peak flow (cfs) Time interval (min) Time to Peak (min) Hyd. volume (cuft) Inflow hyd(s) Maximum elevation (ft) Total strge used (cuft) Hydrograph Description 1 SCS Runoff 48.87 2 720 116,682 ------ ------ ------ Pre Development 2 SCS Runoff 8.156 2 718 18,027 ------ ------ ------ Post Bypass 3 SCS Runoff 75.65 2 720 197,685 ------ ------ ------ Post into Pond 4 Reservoir 7.390 2 762 197,661 3 264.70 90,239 Wet Pond Pre vs Post.gpw Return Period: 1 Year Monday, 12 / 31 / 2018 4 Hydrograph Report Hydraf low Hydrographs Extension for AutoCADO Civil 3D0 2018 by Autodesk, Inc. v12 Monday, 12 / 31 / 2018 Hyd. No. 1 Pre Development Hydrograph type = SCS Runoff Peak discharge = 48.87 cfs Storm frequency = 1 yrs Time to peak = 12.00 hrs Time interval = 2 min Hyd. volume = 116,682 cuft Drainage area = 42.970 ac Curve number = 71.6 Basin Slope = 0.0% Hydraulic length = 0 ft Tc method = TR55 Time of conc. (Tc) = 9.80 min Total precip. = 2.93 in Distribution = Type II Storm duration = 24 hrs Shape factor = 484 Q (cfs) 50.00 40.00 30.00 20.00 10.00 0.00 0 2 4 Hyd No. 1 6 8 Pre Development Hyd. No. 1 -- 1 Year Q (cfs) 50.00 40.00 30.00 20.00 10.00 0.00 10 12 14 16 18 20 22 24 26 Time (hrs) 5 TR55 Tc Worksheet Hydraf low Hydrographs Extension for AutoCADO Civil 3D0 2018 by Autodesk, Inc. v12 Hyd. No. 1 Pre Development Description A B C Totals Sheet Flow Manning's n -value = 0.011 0.011 0.011 Flow length (ft) = 300.0 0.0 0.0 Two-year 24 -hr precip. (in) = 3.54 0.00 0.00 Land slope (%) = 5.00 0.00 0.00 Travel Time (min) = 1.92 + 0.00 + 0.00 = 1.92 Shallow Concentrated Flow Flow length (ft) = 1700.00 0.00 0.00 Watercourse slope (%) = 5.00 0.00 0.00 Surface description = Unpaved Paved Paved Average velocity (ft/s) =3.61 0.00 0.00 Travel Time (min) = 7.85 + 0.00 + 0.00 = 7.85 Channel Flow X sectional flow area (sqft) = 0.00 0.00 0.00 Wetted perimeter (ft) = 0.00 0.00 0.00 Channel slope (%) = 0.00 0.00 0.00 Manning's n -value = 0.015 0.015 0.015 Velocity (ft/s) =0.00 0.00 0.00 Flow length (ft) ({0})0.0 0.0 0.0 Travel Time (min) = 0.00 + 0.00 + 0.00 = 0.00 Total Travel Time, Tc.............................................................................. 9.80 min Hydrograph Report Hydraf low Hydrographs Extension for AutoCADO Civil 3D0 2018 by Autodesk, Inc. v12 Monday, 12 / 31 / 2018 Hyd. No. 2 Post Bypass Hydrograph type = SCS Runoff Peak discharge = 8.156 cfs Storm frequency = 1 yrs Time to peak = 11.97 hrs Time interval = 2 min Hyd. volume = 18,027 cuft Drainage area = 10.350 ac Curve number = 66 Basin Slope = 0.0% Hydraulic length = 0 ft Tc method = TR55 Time of conc. (Tc) = 5.20 min Total precip. = 2.93 in Distribution = Type II Storm duration = 24 hrs Shape factor = 484 Q (cfs) 10.00 m 4.00 2.00 0.00 0 2 4 Hyd No. 2 6 8 Post Bypass Hyd. No. 2 -- 1 Year Q (cfs) 10.00 M . UR 4.00 2.00 0.00 10 12 14 16 18 20 22 24 26 Time (hrs) TR55 Tc Worksheet Hydraflow Hydrographs Extension for AutoCAD® Civil 3D® 2018 by Autodesk, Inc. v12 Hyd. No. 2 Post Bypass Description A B C Totals Sheet Flow Manning's n -value = 0.011 0.011 0.011 Flow length (ft) = 300.0 0.0 0.0 Two-year 24 -hr precip. (in) = 3.54 0.00 0.00 Land slope (%) = 5.00 0.00 0.00 Travel Time (min) = 1.92 + 0.00 + 0.00 = 1.92 Shallow Concentrated Flow Flow length (ft) = 700.00 0.00 0.00 Watercourse slope (%) = 5.00 0.00 0.00 Surface description = Unpaved Paved Paved Average velocity (ft/s) =3.61 0.00 0.00 Travel Time (min) = 3.23 + 0.00 + 0.00 = 3.23 Channel Flow X sectional flow area (sqft) = 0.00 0.00 0.00 Wetted perimeter (ft) = 0.00 0.00 0.00 Channel slope (%) = 0.00 0.00 0.00 Manning's n -value = 0.015 0.015 0.015 Velocity (ft/s) =0.00 0.00 0.00 Flow length (ft) ((0})0.0 0.0 0.0 Travel Time (min) = 0.00 + 0.00 + 0.00 = 0.00 Total Travel Time, Tc.............................................................................. 5.20 min Hydrograph Report Hydraf low Hydrographs Extension for AutoCADO Civil 3D0 2018 by Autodesk, Inc. v12 Monday, 12 / 31 / 2018 Hyd. No. 3 Post into Pond Hydrograph type = SCS Runoff Peak discharge = 75.65 cfs Storm frequency = 1 yrs Time to peak = 12.00 hrs Time interval = 2 min Hyd. volume = 197,685 cuft Drainage area = 41.290 ac Curve number = 81.3 Basin Slope = 0.0% Hydraulic length = 0 ft Tc method = TR55 Time of conc. (Tc) = 12.60 min Total precip. = 2.93 in Distribution = Type II Storm duration = 24 hrs Shape factor = 484 Q (cfs) 80.00 70.00 50.00 FA� 30.00 20.00 10.00 Post into Pond Hyd. No. 3 -- 1 Year Q (cfs) 80.00 70.00 50.00 40.00 30.00 20.00 10.00 0.00 ' ' 0.00 0 2 4 6 8 10 12 14 16 18 20 22 24 26 Hyd No. 3 Time (hrs) �.1 TR55 Tc Worksheet Hydraflow Hydrographs Extension for AutoCAD® Civil 3D® 2018 by Autodesk, Inc. v12 Hyd. No. 3 Post into Pond Description A B C Totals Sheet Flow Manning's n -value = 0.011 0.011 0.011 Flow length (ft) = 300.0 0.0 0.0 Two-year 24 -hr precip. (in) = 3.54 0.00 0.00 Land slope (%) = 2.00 0.00 0.00 Travel Time (min) = 2.77 + 0.00 + 0.00 = 2.77 Shallow Concentrated Flow Flow length (ft) = 1700.00 0.00 0.00 Watercourse slope (%) = 2.00 0.00 0.00 Surface description = Paved Paved Paved Average velocity (ft/s) =2.87 0.00 0.00 Travel Time (min) = 9.86 + 0.00 + 0.00 = 9.86 Channel Flow X sectional flow area (sqft) = 0.00 0.00 0.00 Wetted perimeter (ft) = 0.00 0.00 0.00 Channel slope (%) = 0.00 0.00 0.00 Manning's n -value = 0.015 0.015 0.015 Velocity (ft/s) =0.00 0.00 0.00 Flow length (ft) ((0})0.0 0.0 0.0 Travel Time (min) = 0.00 + 0.00 + 0.00 = 0.00 Total Travel Time, Tc.............................................................................. 12.60 min 10 Hydrograph Report Hydraf low Hydrographs Extension for AutoCADO Civil 3DO 2018 by Autodesk, Inc. v12 Monday, 12 / 31 / 2018 Hyd. No. 4 Wet Pond 70.00 Hydrograph type = Reservoir Peak discharge = 7.390 cfs Storm frequency = 1 yrs Time to peak = 12.70 hrs Time interval = 2 min Hyd. volume = 197,661 cuft Inflow hyd. No. = 3 - Post into Pond Max. Elevation = 264.70 ft Reservoir name = Wet Pond Max. Storage = 90,239 cuft Storage Indication method used. Q (cfs) 80 00 Wet Pond Hyd. No. 4 -- 1 Year Q (cfs) 80 00 0 4 Hyd No. 4 8 12 Hyd No. 3 16 20 24 28 Total storage used = 90,239 cuft 32 Time (hrs) 70.00 70.00 60.00 60.00 50.00 50.00 40.00 40.00 30.00 30.00 20.00 20.00 10.00 0 00 10.00 0 00 0 4 Hyd No. 4 8 12 Hyd No. 3 16 20 24 28 Total storage used = 90,239 cuft 32 Time (hrs) Pond Report 11 Hydraf low Hydrographs Extension for AutoCAD® Civil 3D® 2018 by Autodesk, Inc. v12 Monday, 12 / 31 / 2018 Pond No. 1 - Wet Pond Weir Structures Pond Data [A] Contours -User-defined contour areas. Average end area method used for volume calculation. Begining Elevation = 262.00 ft Stage / Storage Table [A] [B] Stage (ft) Elevation (ft) Contour area (sqft) Incr. Storage (cuft) Total storage (cuft) 0.00 262.00 32,758 0 0 1.00 263.00 25,873 29,316 29,316 2.00 264.00 38,819 32,346 61,662 3.00 265.00 42,316 40,568 102,229 4.00 266.00 46,595 44,456 146,685 5.00 267.00 50,778 48,687 195,371 5.50 267.50 56,334 26,778 222,149 Culvert/ Orifice Structures Weir Structures [A] [B] [C] [PrfRsr] [A] [B] [C] [D] Rise (in) = 36.00 6.00 0.00 0.00 Crest Len (ft) = 10.00 0.00 0.00 0.00 Span (in) = 36.00 6.00 0.00 0.00 Crest EI. (ft) = 265.00 0.00 0.00 0.00 No. Barrels = 1 1 0 0 Weir Coeff. = 2.60 3.33 3.33 3.33 Invert EI. (ft) = 255.50 262.01 0.00 0.00 Weir Type = Broad --- --- --- Length (ft) = 20.00 0.25 0.00 0.00 Multi -Stage = Yes No No No Slope (%) = 1.00 1.00 0.00 n/a N -Value = .013 .013 .013 n/a Orifice Coeff. = 0.60 0.60 0.60 0.60 Exfil.(in/hr) = 0.000 (by Contour) Multi -Stage = n/a Yes No No TW Elev. (ft) = 0.00 Stage (ft) 6.00 5.00 4.00 3.00 2.00 Well 0.00 0.0 40.0 Total Q 80.0 Note: Culvert/Orifice outflows are analyzed under inlet (ic) and outlet (oc) control. Weir risers checked for orifice conditions (ic) and submergence (s). Stage / Discharge Elev (ft) 268.00 267.00 266.00 265.00 264.00 263.00 262.00 120.0 160.0 200.0 240.0 280.0 320.0 360.0 400.0 440.0 Discharge (cfs) iv Hydrograph Summary Report Hydraf low Hydrographs Extension for AutoCAD® Civil 3D® 2018 by Autodesk, Inc. v12 Hyd. No. Hydrograph type (origin) Peak flow (cfs) Time interval (min) Time to Peak (min) Hyd. volume (cuft) Inflow hyd(s) Maximum elevation (ft) Total strge used (cuft) Hydrograph Description 1 SCS Runoff 75.60 2 720 175,294 ------ ------ ------ Pre Development 2 SCS Runoff 14.00 2 718 28,957 ------ ------ ------ Post Bypass 3 SCS Runoff 105.03 2 720 272,533 ------ ------ ------ Post into Pond 4 Reservoir 20.61 2 736 272,510 3 265.38 119,147 Wet Pond Pre vs Post.gpw Return Period: 2 Year Monday, 12 / 31 / 2018 13 Hydrograph Report Hydraf low Hydrographs Extension for AutoCADO Civil 3DO 2018 by Autodesk, Inc. v12 Monday, 12 / 31 / 2018 Hyd. No. 1 Pre Development Hydrograph type = SCS Runoff Peak discharge = 75.60 cfs Storm frequency = 2 yrs Time to peak = 12.00 hrs Time interval = 2 min Hyd. volume = 175,294 cuft Drainage area = 42.970 ac Curve number = 71.6 Basin Slope = 0.0% Hydraulic length = 0 ft Tc method = TR55 Time of conc. (Tc) = 9.80 min Total precip. = 3.54 in Distribution = Type II Storm duration = 24 hrs Shape factor = 484 Q (cfs) 80.00 70.00 50.00 FA� 30.00 20.00 10.00 Pre Development Hyd. No. 1 -- 2 Year Q (cfs) 80.00 70.00 50.00 40.00 30.00 20.00 10.00 0.00 -F— �i 0.00 0 2 4 6 8 10 12 14 16 18 20 22 24 26 Hyd No. 1 Time (hrs) 14 Hydrograph Report Hydraf low Hydrographs Extension for AutoCADO Civil 3DO 2018 by Autodesk, Inc. v12 Monday, 12 / 31 / 2018 Hyd. No. 2 Post Bypass Hydrograph type = SCS Runoff Peak discharge = 14.00 cfs Storm frequency = 2 yrs Time to peak = 11.97 hrs Time interval = 2 min Hyd. volume = 28,957 cuft Drainage area = 10.350 ac Curve number = 66 Basin Slope = 0.0% Hydraulic length = 0 ft Tc method = TR55 Time of conc. (Tc) = 5.20 min Total precip. = 3.54 in Distribution = Type II Storm duration = 24 hrs Shape factor = 484 Q (cfs) 15.00 12.00 • el .M 3.00 0.00 0 2 4 Hyd No. 2 6 8 Post Bypass Hyd. No. 2 -- 2 Year Q (cfs) 15.00 12.00 • IR M 3.00 — ' 0.00 10 12 14 16 18 20 22 24 26 Time (hrs) 15 Hydrograph Report Hydraf low Hydrographs Extension for AutoCADO Civil 3D0 2018 by Autodesk, Inc. v12 Monday, 12 / 31 / 2018 Hyd. No. 3 Post into Pond Hydrograph type = SCS Runoff Peak discharge = 105.03 cfs Storm frequency = 2 yrs Time to peak = 12.00 hrs Time interval = 2 min Hyd. volume = 272,533 cuft Drainage area = 41.290 ac Curve number = 81.3 Basin Slope = 0.0% Hydraulic length = 0 ft Tc method = TR55 Time of conc. (Tc) = 12.60 min Total precip. = 3.54 in Distribution = Type II Storm duration = 24 hrs Shape factor = 484 Q (cfs) 120.00 100.00 FA� 20.00 0.00 0 2 4 Hyd No. 3 6 8 Post into Pond Hyd. No. 3 -- 2 Year Q (cfs) 120.00 100.00 40.00 20.00 "0— 1 1 1 11 1 i 0.00 10 12 14 16 18 20 22 24 26 Time (hrs) 16 Hydrograph Report Hydraf low Hydrographs Extension for AutoCADO Civil 3DO 2018 by Autodesk, Inc. v12 Monday, 12 / 31 / 2018 Hyd. No. 4 Wet Pond Hydrograph type = Reservoir Peak discharge = 20.61 cfs Storm frequency = 2 yrs Time to peak = 12.27 hrs Time interval = 2 min Hyd. volume = 272,510 cuft Inflow hyd. No. = 3 - Post into Pond Max. Elevation = 265.38 ft Reservoir name = Wet Pond Max. Storage = 119,147 cuft Storage Indication method used. JITM =Ir Q (cfs) Hyd. No. 4 -- 2 Year Q (cfs) 120.00 120.00 100.00 100.00 80.00 80.00 60.00 60.00 40.00 40.00 20.00 L20.00 0.00 0.00 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Time (hrs) Hyd No. 4 Hyd No. 3 Total storage used = 119,147 cuft `IN Hydrograph Summary Report Hydraf low Hydrographs Extension for AutoCAD® Civil 3D® 2018 by Autodesk, Inc. v12 Hyd. No. Hydrograph type (origin) Peak flow (cfs) Time interval (min) Time to Peak (min) Hyd. volume (cuft) Inflow hyd(s) Maximum elevation (ft) Total strge used (cuft) Hydrograph Description 1 SCS Runoff 152.24 2 720 348,494 ------ ------ ------ Pre Development 2 SCS Runoff 31.51 2 718 63,022 ------ ------ ------ Post Bypass 3 SCS Runoff 183.71 2 720 478,116 ------ ------ ------ Post into Pond 4 Reservoir 126.50 2 726 478,092 3 266.25 158,039 Wet Pond Pre vs Post.gpw Return Period: 10 Year Monday, 12 / 31 / 2018 18 Hydrograph Report Hydraf low Hydrographs Extension for AutoCADO Civil 3DO 2018 by Autodesk, Inc. v12 Monday, 12 / 31 / 2018 Hyd. No. 1 Pre Development Hydrograph type = SCS Runoff Peak discharge = 152.24 cfs Storm frequency = 10 yrs Time to peak = 12.00 hrs Time interval = 2 min Hyd. volume = 348,494 cuft Drainage area = 42.970 ac Curve number = 71.6 Basin Slope = 0.0% Hydraulic length = 0 ft Tc method = TR55 Time of conc. (Tc) = 9.80 min Total precip. = 5.09 in Distribution = Type II Storm duration = 24 hrs Shape factor = 484 Q (cfs) 160.00 140.00 120.00 100.00 40.00 20.00 Pre Development Hyd. No. 1 -- 10 Year Q (cfs) 160.00 140.00 120.00 100.00 40.00 20.00 0.00 ' ' ' 0.00 0 2 4 6 8 10 12 14 16 18 20 22 24 26 Hyd No. 1 Time (hrs) Hydrograph Report 19 Hydraf low Hydrographs Extension for AutoCADO Civil 3DO 2018 by Autodesk, Inc. v12 Hyd. No. 2 Post Bypass Hydrograph type = SCS Runoff Peak discharge Storm frequency = 10 yrs Time to peak Time interval = 2 min Hyd. volume Drainage area = 10.350 ac Curve number Basin Slope = 0.0% Hydraulic length Tc method = TR55 Time of conc. (Tc) Total precip. = 5.09 in Distribution Storm duration = 24 hrs Shape factor Monday, 12 / 31 / 2018 = 31.51 cfs = 11.97 hrs = 63,022 cuft = 66 = 0 ft = 5.20 min = Type II = 484 Q (cfs) 35.00 Post Bypass Hyd. No. 2 -- 10 Year Q (cfs) 35.00 30.00 30.00 25.00 25.00 20.00 20.00 15.00 15.00 10.00 10.00 5.00 5.00 0.00 0.00 0 2 4 6 8 10 12 14 16 18 20 22 Hyd No. 2 24 26 Time (hrs) Hydrograph Report 20 Hydraf low Hydrographs Extension for AutoCADO Civil 3DO 2018 by Autodesk, Inc. v12 Hyd. No. 3 Post into Pond Hydrograph type = SCS Runoff Peak discharge Storm frequency = 10 yrs Time to peak Time interval = 2 min Hyd. volume Drainage area = 41.290 ac Curve number Basin Slope = 0.0% Hydraulic length Tc method = TR55 Time of conc. (Tc) Total precip. = 5.09 in Distribution Storm duration = 24 hrs Shape factor Monday, 12 / 31 / 2018 = 183.71 cfs = 12.00 hrs = 478,116 cuft = 81.3 = 0 ft = 12.60 min = Type II = 484 Q (cfs) 210.00 Post into Pond Hyd. No. 3 -- 10 Year Q (cfs) 210.00 180.00 180.00 150.00 150.00 120.00 120.00 90.00 90.00 60.00 60.00 30.00 30.00 0.00 0 2 4 6 8 10 Hyd No. 3 12 14 16 18 20 22 0.00 24 26 Time (hrs) 21 Hydrograph Report Hydraf low Hydrographs Extension for AutoCADO Civil 3DO 2018 by Autodesk, Inc. v12 Monday, 12 / 31 / 2018 Hyd. No. 4 Wet Pond Hydrograph type = Reservoir Peak discharge = 126.50 cfs Storm frequency = 10 yrs Time to peak = 12.10 hrs Time interval = 2 min Hyd. volume = 478,092 cuft Inflow hyd. No. = 3 - Post into Pond Max. Elevation = 266.25 ft Reservoir name = Wet Pond Max. Storage = 158,039 cuft Storage Indication method used. JITM =Ir Q (cfs) Hyd. No. 4 -- 10 Year Q (cfs) 210.00 210.00 180.00 180.00 150.00 150.00 120.00 120.00 90.00 90.00 60.00 60.00 30.00 30.00 0.00 0.00 0 2 4 6 8 10 12 14 16 18 20 22 24 26 Time (hrs) Hyd No. 4 Hyd No. 3 Total storage used = 158,039 cuft 0r Hydrograph Summary Report Hydraf low Hydrographs Extension for AutoCAD® Civil 3D® 2018 by Autodesk, Inc. v12 Hyd. No. Hydrograph type (origin) Peak flow (cfs) Time interval (min) Time to Peak (min) Hyd. volume (cuft) Inflow hyd(s) Maximum elevation (ft) Total strge used (cuft) Hydrograph Description 1 SCS Runoff 201.49 2 718 460,975 ------ ------ ------ Pre Development 2 SCS Runoff 42.92 2 718 85,950 ------ ------ ------ Post Bypass 3 SCS Runoff 231.09 2 720 605,075 ------ ------ ------ Post into Pond 4 Reservoir 187.18 2 726 605,051 3 266.55 172,767 Wet Pond Pre vs Post.gpw Return Period: 25 Year Monday, 12 / 31 / 2018 Hydrograph Report 23 Hydraf low Hydrographs Extension for AutoCADO Civil 3D0 2018 by Autodesk, Inc. v12 Hyd. No. 1 Pre Development Hydrograph type = SCS Runoff Peak discharge Storm frequency = 25 yrs Time to peak Time interval = 2 min Hyd. volume Drainage area = 42.970 ac Curve number Basin Slope = 0.0% Hydraulic length Tc method = TR55 Time of conc. (Tc) Total precip. = 6.00 in Distribution Storm duration = 24 hrs Shape factor Monday, 12 / 31 / 2018 = 201.49 cfs = 11.97 hrs = 460,975 cuft = 71.6 = 0 ft = 9.80 min = Type II = 484 Q (cfs) 210.00 Pre Development Hyd. No. 1 -- 25 Year Q (cfs) 210.00 180.00 180.00 150.00 150.00 120.00 120.00 90.00 90.00 60.00 60.00 30.00 30.00 0.00 0 2 4 6 8 10 Hyd No. 1 12 14 16 18 20 22 0.00 24 26 Time (hrs) 24 Hydrograph Report Hydraf low Hydrographs Extension for AutoCADO Civil 3D0 2018 by Autodesk, Inc. v12 Monday, 12 / 31 / 2018 Hyd. No. 2 Post Bypass Hydrograph type = SCS Runoff Peak discharge = 42.92 cfs Storm frequency = 25 yrs Time to peak = 11.97 hrs Time interval = 2 min Hyd. volume = 85,950 cuft Drainage area = 10.350 ac Curve number = 66 Basin Slope = 0.0% Hydraulic length = 0 ft Tc method = TR55 Time of conc. (Tc) = 5.20 min Total precip. = 6.00 in Distribution = Type II Storm duration = 24 hrs Shape factor = 484 Q (cfs) 50.00 40.00 30.00 20.00 10.00 0.00 0 2 4 Hyd No. 2 6 8 Post Bypass Hyd. No. 2 -- 25 Year Q (cfs) 50.00 40.00 30.00 20.00 10.00 I— ' 0.00 10 12 14 16 18 20 22 24 26 Time (hrs) 25 Hydrograph Report Hydraf low Hydrographs Extension for AutoCADO Civil 3D0 2018 by Autodesk, Inc. v12 Monday, 12 / 31 / 2018 Hyd. No. 3 Post into Pond Hydrograph type = SCS Runoff Peak discharge = 231.09 cfs Storm frequency = 25 yrs Time to peak = 12.00 hrs Time interval = 2 min Hyd. volume = 605,075 cuft Drainage area = 41.290 ac Curve number = 81.3 Basin Slope = 0.0% Hydraulic length = 0 ft Tc method = TR55 Time of conc. (Tc) = 12.60 min Total precip. = 6.00 in Distribution = Type II Storm duration = 24 hrs Shape factor = 484 Q (cfs) 240.00 210.00 180.00 150.00 120.00 30.00 Post into Pond Hyd. No. 3 -- 25 Year Q (cfs) 240.00 210.00 180.00 150.00 120.00 30.00 0.00 0.00 0 2 4 6 8 10 12 14 16 18 20 22 24 26 Hyd No. 3 Time (hrs) 26 Hydrograph Report Hydraf low Hydrographs Extension for AutoCADO Civil 3D0 2018 by Autodesk, Inc. v12 Monday, 12 / 31 / 2018 Hyd. No. 4 Wet Pond Hydrograph type = Reservoir Peak discharge = 187.18 cfs Storm frequency = 25 yrs Time to peak = 12.10 hrs Time interval = 2 min Hyd. volume = 605,051 cuft Inflow hyd. No. = 3 - Post into Pond Max. Elevation = 266.55 ft Reservoir name = Wet Pond Max. Storage = 172,767 cuft Storage Indication method used. JITM =Ir Q (cfs) Hyd. No. 4 -- 25 Year Q (cfs) 240.00 240.00 210.00 210.00 180.00 180.00 150.00 150.00 120.00 120.00 90.00 90.00 60.00 60.00 30.00 30.00 0.00 0.00 0 2 4 6 8 10 12 14 16 18 20 22 24 26 Time (hrs) Hyd No. 4 Hyd No. 3 Total storage used = 172,767 cuft coor jjj..=� . .... - � 0 - -_- pp ZED SIG TIoN ter_ ---- _ _ - -+oa IN-TERSEG f-dJf sr� 1�EQl v N 47 F., t o co 0 —_— --- — Ala+oo J-�--_- `\ `\ ! j ♦ ` \ / SLEV• 305-871 _fir^ / j ? �"' t \ \\ { ♦ ` \-- / 1 Is noo !�� ��== 294 '10+ Ut 11101 doff % app I94 X \ '`'3r?5 -/� L���r t \\ ` �.\ \\ \ ♦♦ / V r! \ \ \ 1 300, O�Q� 29 � � �\ \ \ \ \ � �.\ \�\ - \ ♦ _- 0 _ / �0 289- 0/0 Try\ \ x 1.21Ac. 295---- \ � 145 Ac' ��`� -' 289 t \ \ 2 04� ., � -- � 150' �. _�-- 1 1 �n � ' r' \\ \ \ tun)� \ ♦\ -_� j \ -1291 $ 91 291- ���ti. -T 1.74 -TC 291.70 2!0 -295 Tc291.70 AI;p � �, •\ � � \\ `� \ \\ \ T�22g Pub \ J . ASP \ 7 SF r >A o � \ \ \ +48 + 5. ,38 Ac. �/J r �uTUN� �2�a \ 74 3 Z L LOPM \ \ t ,440 S \\ .�.3 6o v A AM 1=� ,PVAVV 1131, N, lzuw Orr A ASE 291 6\ \ 89\4` \ r� ` z No ` \ 2\Lai 289 r NI - \ EXISTING MM ANDS \ \ VREAM 70 REA/AIN \ (DO NOT DISTURB) \ 200 %%%744 LO LOPM 4 q7 At, - at -0 Xykoa ! 1 by y 1 �80, 78 -_ - ZZ z \ .1 \ �1� ccv / l \ 5\ \ J SCALES 1' = 60' 0 60 120 150 180 210 240 � rA -tOREMAtN l 4 CA 00 X O d5 m `r' O^ N w 0 r m O U 6 Z Ld w w z z z Z w Y U O W r to LL, LL, WV) zZ� O "-3 t— m Z CV � U <z Zw ¢� Ww5 z m z BLN—C-1874 1111 ••V. IN � CArRp�'% SE 3 '��� • . G 1 NE.E-fZ! ILL 8 / `\ QRA17/NCii PLAN NZ ZZ BYPASS1 \ \ \ _ \ 1 \ \ ti 2T�\ \ N, _-`27 � 1 TO THEN, 'FEAR NOT. FOR BEHOLD, I BRING YOU GOOD TIDINGS OF GREAT JOY, WHICH SHALL BE TO ALL PEOPLE. YOU IS BORN THIS DAY IN THE CITY OF DAVID A SAVIOR, WHO IS CHRIST THE LORD. LUKE 2: 10-11 REVISIONS FILE NO. 2018-033 HORZ. SCALE 1--60- VERT. SCALE: NONE 03 CE- Stocks Engineering, P.A. 1100 Eastern Avenue PO Box 1108 Nashville, NC 27856 PROJECT: Flowers - Publix DATE: December 18, 2018 PAGE: 1 of 1 Post -Development Tc Area ID Area (Ac.) C 1 110 Q10 (cfs) 5 I I b 0.95 0.85 7.44 6.01 15 la 2.84 0.73 5.58 11.57 5 Ib 0.21 0.70 7.44 1.09 5 Ic 1.20 0.82 7.44 7.32 5 Id 0.07 0.90 7.44 0.47 5 le 0.15 0.90 7.44 1.00 5 If 0.19 0.83 7.44 1.17 5 Ig 0.20 0.90 7.44 1.34 15 Ih 1.92 0.68 5.58 7.29 30 Ii 2.62 0.35 3.63 3.33 5 Ij 0.18 0.90 7.44 1.21 30 Ik 4.51 0.35 3.63 5.73 5 II 0.26 0.85 7.44 1.64 30 IM 0.68 0.35 3.63 0.86 30 In 3.61 0.35 3.63 4.59 5 10 0.04 0.85 7.44 0.25 5 1p 0.02 0.70 7.44 0.10 5 Iq 0.09 0.70 7.44 0.47 5 Ir 0.20 0.64 7.44 0.95 5 Is 0.56 0.62 7.44 2.58 5 It 1 2.25 1 0.80 1 7.44 13.39 15 Ila 1.60 0.87 5.58 7.77 5 I I b 0.95 0.85 7.44 6.01 5 IIc 1.00 0.85 7.44 6.32 5 lid 0.99 0.85 7.44 6.26 5 Ile 0.56 0.77 7.44 3.21 5 IIf 0.11 0.57 7.44 0.47 5 lig 0.07 0.90 7.44 0.47 5 IIh 0.01 0.22 7.44 0.02 5 Ili 0.04 0.85 7.44 0.25 5 II' 0.03 0.90 7.44 0.20 5 Ilk 0.26 0.60 7.44 1.16 5 III 0.08 0.90 7.44 0.54 5 IIm 0.14 0.58 7.44 0.60 5 lin 0.03 0.90 7.44 0.20 5 110 0.01 0.22 7.44 0.02 5 lip 0.09 0.41 7.44 0.27 5 IIq 0.10 0.90 7.44 0.67 5 lir 0.07 0.90 7.44 0.47 5 IIs 0.10 0.75 7.44 0.56 5 lit 1.18 0.90 7.44 7.90 5 Ilu 0.70 0.90 7.44 4.69 5 IIv 0.04 0.90 7.44 0.27 5 Ilw 0.08 0.57 7.44 0.34 Runoff Computations 10 -Year Storm Hydraflow Storm Sewers Extension for Autodesk® AutoCAD® Civil 3D® Plan Storm Sewers v12.00 Storm Sewer Summary Report Page 1 Line Line ID Flow Line Line Line Invert Invert Line HGL HGL Minor HGL Dns Junction No. rate Size shape length EL Dn EL Up Slope Down Up loss Junct Line Type (cfs) (in) (ft) (ft) (ft) N (ft) (ft) (ft) (ft) No. 1 CB2 to FES1 115.0 48 Cir 170.318 265.13 266.87 1.022 268.36 270.10 1.74 270.10 End Manhole 2 CB18 to CB2 66.35 48 Cir 91.184 266.97 267.41 0.483 270.10 269.87 n/a 269.87 1 Manhole 3 CB21 to CB18 49.43 42 Cir 263.456 271.68 276.52 1.837 273.14 278.72 0.94 278.72 2 Manhole 4 CB23 to CB21 48.86 36 Cir 61.444 276.62 277,20 0.944 278.72 279.47 n/a 279.47 3 Manhole 5 CB24 to CB23 44.02 36 Cir 29.155 277.30 278.23 3.190 279.47 280.39 n/a 280.39 j 4 Manhole 6 CB25 to CB24 43.16 36 Cir 322.175 278.33 280.77 0.757 280.39 282.91 n/a 282.91 5 Manhole 7 CB27 to CB25 35.79 36 Cir 208.129 280.87 283.06 1.052 282.91 285.00 n/a 285.00 j 6 Manhole 8 CB29 to CB27 31.25 36 Cir 197.510 283.16 284.31 0.582 285.00 286.12 n/a 286.12 j 7 Manhole 9 CB30 to CB29 23.96 30 Cir 57,949 284.41 2844.70 0.500 286.14 286.43 0.67 287.10 8 Manhole 10 CB31 to CB30 22.87 30 Cir 65.597 284.80 285.14 0.518 287.10 287.23 0,42 287.65 9 Manhole 11 CB42 to CB31 11.57 18 Cir 210.869 285.24 299.40 6.715 287.65 300.70 n/a 300.70 j 10 Manhole 12 CB3 to CB2 48.33 36 Cir 117.963 272.84 275.69 2.416 274.28 277.95 1.09 277.95 1 Manhole 13 CB4 to CB3 48.06 36 Cir 25.274 275.79 276.31 2.057 277.95 278.57 n/a 278.57 12 Manhole 14 CB5 to CB4 33.50 36 Cir 59.712 276.41 277.53 1.876 278.57 279.41 n/a 279.41 j 13 Manhole 15 CBS to CB5 32.68 36 Cir 109.580 277.63 279.77 1.953 279.41 281.62 0.79 281.62 14 Manhole 16 CB10 to CBS 30.98 36 Cir 240.923 279.87 281.24 0.569 281.62 283.04 n/a 283.04 15 Manhole 17 CB12 to CB10 30.53 36 Cir 92.366 281.34 281.79 0.487 283.11 283.58 0.75 283.58 16 Manhole 18 CB13 to CB12 8.26 24 Cir 25.000 281.89 282.02 0.520 283.58 283.04 nla 283.04 17 Manhole 19 CB41 to CB13 7.77 18 Cir 172.817 282.12 290.40 4.791 283.04 291.48 n/a 291.48 18 Manhole 20 CB32 to CB31 9.96 24 Cir 47.824 285.24 285.46 0.460 287.65* 287.75* 0.08 287.82 10 Manhole 21 CB38 to CB32 7.79 18 Cir 47.365 285.56 285.81 0.528 287.82* 288.08" 0.05 288.13 20 Manhole 22 CB39 to CB38 7.32 18 Cir 108.462 285.91 287.10 1.097 288.13 288.59 0.27 288.86 21 Manhole 23 CB33 to CB32 1.00 18 Cir 36.367 285.56 285.70 0.385 287.82* 287.82* 0.00 287.83 20 Manhole Project File: Storm Drain System 3.stm Number of lines: 42 Run Date: 1/10/2019 NOTES: Known Qs only ; *Surcharged (HGL above crown). ; j - Line contains hyd. jump. Storm Sewers v12.00 Storm Sewer Summary Report Page 2 Line Line ID Flow Line Line Line Invert Invert Line HGL HGL Minor HGL Dns Junction No. rate Size shape length EL Dn EL Up Slope Down Up loss Junct Line Type (cfs) (in) (ft) (ft) (ft) N R (ft) (ft) (ft) No. 24 CB28 to CB27 1.21 18 Cir 30.881 283.16 284.40 4.015 285.00 284.98 0.06 285.03 7 Manhole 25 CB43 to CB12 21.80 24 Cir 24.071 281.89 281.99 0.415 283.89* 284.11* 0.11 284.23 17 Manhole 26 CB15 to CB43 18.59 24 Cir 115.251 282.09 282.66 0.495 284.23* 285.01' 0.08 285.09 25 Manhole 27 CB16 to CB15 12.33 24 Cir 115.751 282.76 283.33 0.492 285.09* 285.43* 0.04 285.47 26 Manhole 28 CB17 to CB16 6.01 24 Cir 116.251 283.43 284.00 0.490 285.47 285.53 0.08 285.61 27 Manhole 29 CB34 to C134 14.29 24 Cir 85.364 278.84 280.46 1.898 279.79 281.82 0.61 281.82 13 Manhole 30 CB36 to CB34 1.14 18 Cir 25.305 280.56 281.86 5.137 281.82 282.26 nla 282.26 j 29 Manhole 31 CB37 to CB36 0.67 18 Cir 40.317 281.96 283.81 4.589 282.26 284.11 0.11 284.11 30 Manhole 32 CB35 to CB34 12.59 24 Cir 136.646 280.56 281.94 1.010 281.82 283.21 0.14 283.21 29 Manhole 33 CB40 to CB35 7.90 18 Cir 111.000 282.04 283.23 1.072 283.21 284.32 n/a 284.32 j 32 Manhole 34 DI14 to CB13 0.02 18 Cir 10.500 282.12 282.28 1.524 283.04 282.33 0.02 282.33 18 Manhole 35 CB26 to CB25 1.64 18 Cir 25.000 280.87 282.15 5.120 282.91 282.88 0.06 282.94 6 Manhole 36 CB11 to CB10 0.20 18 Cir 25.500 281.34 281.86 2.039 283.04 283.04 0.00 283.04 16 Manhole 37 C139 to CB8 0.54 18 Cir 25.500 279.87 280.39 2.039 281.62 281.62 0.00 281.62 15 Manhole 38 CB6 to CB5 0.22 18 Cir 28.434 277.63 278.21 2.040 279.41 279.41 0.00 279.41 14 Manhole 39 D17 to CB6 0.02 18 Cir 9.906 278.31 278.47 1.615 279.41 278.52 0.02 278.52 38 Manhole 40 CB22 to CB21 0.47 18 Cir 25.000 276.62 277.14 2.080 278.72* 278.72* 0.00 278.72 3 Manhole 41 CB19 to CB18 15.97 30 Cir 25.000 271.68 272.52 3.360 272.46 273.87 nla 273.87 2 Manhole 42 D120 to CB19 13.39 24 Cir 18.500 272.62 272.70 0.433 274.10 274.19 0.45 274.63 41 Manhole Project File: Storm Drain System 3.stm Number of lines: 42 Run Date: 1110/2019 NOTES: Known Qs only ; *Surcharged (HGL above crown). ; j - Line contains hyd. jump. Storm Sewers v12.00 Hydraulic Grade Line Computations Page 1 Line Size Q Downstream Len Upstream Check JL Minor coeff loss Invert HGL Depth Area Vel Vel EGL Sf Invert HGL Depth Area Val Vel EGL Sf Ave Enrgy elev elev head elev elev elev head elev Sf loss (in) (Cfs) (ft) (ft) (ft) (s9ft) MIS) (ft) (ft) N (ft) (ft) (ft) (ft) (Sgft) (ftls) (ft) (ft) N N (ft) (K) (ft) 1 48 115.0 265.13 268.36 3.23 10.87 10.58 1.74 270.10 0.000 170.31 266.87 270.10 3.23"* 10.88 10.57 1.74 271.84 0.000 0.000 nla 1.00 1.74 2 48 66.35 266.97 270.10 3.13 8.10 6.28 1.04 271.15 0.000 91.184 267.41 269.87 2.46** 8.10 8.20 1.04 270.91 0.000 0.000 n/a 1.00 n/a 3 42 49.43 271.68 273.14 1.46* 3.79 13.03 0.94 274.08 0.000 263.45 5276.52 278.72 2.20"* 6.35 7.78 0.94 279.66 0.000 0.000 n/a 1.00 0.94 4 36 48.86 276.62 278.72 2,10 5.27 9.27 1.12 279.84 0.000 61.444 277.20 279.47 2.27** 5.75 8.50 1.12 280.60 0.000 0.000 n/a 0.97 nla 5 36 44.02 277.30 279.47 2.17 5.45 8.02 1.02 280.49 0.000 29.155 278.23 280.39 j 2.16"* 5.45 8.08 1.02 281.40 0.000 0.000 n/a 0.88 0.89 6 36 43.16 278.33 280.39 2.06 5.17 8.34 1.00 281.39 0.000 322.17 280.77 282.91 2.14** 5.39 8.01 1.00 283.91 0.000 0.000 n/a 1.00 n/a 7 36 35.79 280.87 282.91 2.04 4.84 7.00 0.85 283.76 0.000 208.12 D283,06 285.00 j 1.94"* 4.84 7.39 0.85 285.85 0.000 0.000 nla 1.00 n/a 8 36 31.25 283.16 285.00 1.84 4.46 6.86 0.76 285.77 0.000 197.51 284.31 286.12 j 1.81** 4.46 7.01 0.76 286.88 0.000 0.000 nla 0.64 n/a 9 30 23.96 284.41 286.14 1.73* 3.63 6.60 0.68 286.82 0.500 57.949 284.70 286.43 1.73 3.62 6.61 0.68 287.11 0.502 0.501 0.290 0.99 0.67 10 30 22.87 284.80 287.10 2.30 4.73 4.84 0.36 287.47 0.270 65.597 285.14 287.23 2.09 4.38 5.22 0.42 287.65 0.301 0.285 0.187 1.00 0.42 11 18 11.57 285.24 287.65 1.50 1,62 6.55 0.67 288.32 1.214 210.86 299.40 300.70 j 1.30*" 1.62 7.13 0.79 301.49 1.118 1.166 n/a 1.00 n/a 12 36 48.33 272.84 274.28 1.44* 3.36 14.40 1.11 275.39 0.000 117.96 275.69 277.95 2.26** 5.72 8.45 1.11 279.06 0.000 0.000 n/a 0.98 1.09 13 36 48.06 275.79 277.95 2.16 5.45 8.81 1.10 279.06 0.000 25.274 276.31 278.57 2.26** 5.70 8.43 1.10 279.67 0.000 0.000 n/a 0.93 nla 14 36 33.50 276.41 278.57 2.16 4.66 6.16 0.80 279.37 0.000 59.712 277.53 279.41 j 1.88- 4.66 7.20 0.80 280.21 0.000 0.000 n/a 0.94 n/a 15 36 32.68 277.63 279.41 1.78 4.36 7.49 0.79 280.20 0.000 109.58 279.77 281.62 1.85** 4.59 7.13 0.79 282,41 0.000 0.000 n/a 1.00 0.79 16 36 30.98 279.87 281.62 1.75 4.29 7.22 0.76 282.38 0.000 240.92 3281.24 283.04 1.80** 4.44 6.98 0.76 283.80 0.000 0.000 n/a 1.00 n/a 17 36 30.53 281.34 283.11 1.77* 4.35 7.02 0.75 283.86 0.000 92.366 281.79 283.58 1.79** 4.40 6.94 0.75 284.33 0.000 0.000 n/a 1.00 0.75 18 24 8.26 281.89 283.58 1.69 1.62 2.92 0.41 283.99 0.000 25.000 282.02 283.04 1.02`"` 1.62 5.11 0.41 283.45 0.000 0.000 n/a 1.00 n/a 19 18 7.77 282.12 283.04 0.92 1.14 6.81 0.51 283.55 0.000 172.81 290.40 291.48 1.08** 1.36 5.71 0.51 291.99 0.000 0.000 n/a 1.00 n/a 20 24 9.96 285.24 287.65 2.00 3.14 3.17 0.16 287.81 0.194 47.824 285.46 287.75 2.00 3.14 3.17 0.16 287.90 0.194 0.194 0.093 0.48 0.08 21 18 7.79 285.56 287.82 1.50 1.77 4.41 0.30 288.12 0.551 47.365 285.81 288.08 1.50 1.77 4.41 0.30 288.38 0.550 0.550 0.261 0.15 0.05 Project File: Storm Drain System 3.stm Number of lines: 42 Run Date: 1/10/2019 Notes: * depth assumed; ** Critical depth.; j -Line contains hyd. jump ; c = cir e = ellip b = box Storm Sewers v12.00 Hydraulic Grade Line Computations Page 2 Line Size Q Downstream Len Upstream Check JL Minor coeff loss Invert HGL Depth Area Vel Vel EGL Sf Invert HGL Depth Area Vel Vel EGL Sf Ave Enrgy elev elev head elev elev elev head elev Sf loss (in) (cfs) (ft) (ft) (ft) (soft) (ftls) (ft) (ft) N (ft) (ft) (ft) (ft) (sgft) (ft1s) (ft) (ft) N N (ft) (K) (ft) 22 18 7.32 285.91 288.13 1.50 1.77 4.14 0.27 288.39 0.486 108.46 87.10 288.59 1.49 1.77 4.15 0.27 288.86 0.456 0.471 0.511 1.00 0.27 23 18 1.00 285.56 287.82 1.50 1.77 0.57 0.00 287.83 0.009 36.367 285.70 287.82 1.50 1.77 0.57 0.00 287.83 0.009 0.009 0.003 1.00 0.00 24 18 1.21 283.16 285.00 1.50 1.77 0.68 0.01 285.01 0.013 30.881 284,40 284.98 0.58 0.63 1.94 0.06 285.03 0.136 0.074 0.023 1.00 0.06 25 24 21.80 281.89 283.89 2.00" 3.14 6.94 0.75 284.64 0.929 24.071 281.99 284.11 2.00 3.14 6.94 0.75 284.86 0.929 0.929 0.224 0.15 0.11 26 24 18.59 282.09 284.23 2.00 3.14 5.92 0.54 284.77 0.676 115.25 282.66 285.01 2.00 3.14 5.92 0.54 285.55 0.676 0.676 0.779 0.15 0.08 27 24 12.33 282.76 285.09 2.00 3.14 3.93 0.24 285.33 0.297 115.75 283.33 285.43 2.00 3.14 3.92 0.24 285.67 0.297 0.297 0.344 0.15 0.04 28 24 6.01 283.43 285.47 2,00 3.14 1.91 0.06 285.52 0.071 116.25 284.00 285.53 1.53 2.57 2.33 0.08 285.61 0.081 0.076 0.088 1.00 0.08 29 24 14.29 278.84 279.79 0.95' 1.47 9.70 0.61 280.40 0.000 85.364 280.46 281.82 1.36** 2.28 6.28 0.61 282.43 0.000 0.000 nla 1.00 0.61 30 18 1.14 280.56 281.82 1.26 0.38 0.72 0.14 281.96 0.000 25.305 281.86 282.26 j 0.40" 0.38 3.03 0.14 282,40 0.000 0.000 n/a 0.17 0.02 31 18 0.67 281.96 282,26 0.30 0.25 2.68 0.11 282.36 0.000 40.317 283.81 284.11 0.30** 0.26 2.62 0.11 284.22 0.000 0.000 n/a 1.00 0.11 32 24 12.59 280.56 281.82 1.26 2.09 6.03 0.55 282.37 0.000 136,64 281.94 283.21 1.27'"* 2.11 5.96 0.55 283.77 0.000 0.000 n/a 0.25 0.14 33 18 7.90 282.04 283.21 1.17 1.37 5.32 0.51 283.73 0.000 111.00 D283.23 284.32 j 1.09*' 1.37 5.75 0.51 284.83 0.000 0.000 nla 1.00 0.51 34 18 0.02 282,12 283.04 0.92 0.02 0.02 0.02 283.06 0.000 10.500 282.28 282.33 0.05- 0.02 1.06 0.02 282.35 0.000 0.000 nla 1.00 0.02 35 18 1.64 280.87 282.91 1.50 1.77 0.93 0.01 282.92 0.024 25.000 282.15 282.88 0.73 0.85 1.92 0.06 282.94 0.107 0.066 0.016 1.00 0.06 36 18 0.20 281.34 283.04 1.50 1.77 0.11 0.00 283.04 0.000 25.500 281.86 283.04 1.18 1,49 0.13 0.00 283.04 0.000 0.000 0.000 1.00 0.00 37 18 0.54 279.87 281.62 1.50 1.77 0.31 0.00 281.63 0.003 25.500 280.39 281.62 1.23 1.55 0.35 0.00 281.62 0.003 0.003 0.001 1.00 0.00 38 18 0.22 277.63 279.41 1.50 1.77 0.12 0.00 279.41 0.000 28.434 278.21 279.41 1.20 1.51 0.15 0.00 279.41 0.000 0.000 0.000 0.54 0.00 39 18 0.02 278.31 279.41 1.10 0.02 0.01 0.02 279.43 0.000 9.906 278.47 278.52 0.05** 0.02 1.06 0.02 278.54 0.000 0.000 n/a 1.00 0.02 40 18 0.47 276.62 278.72 1.50 1.77 0.27 0,00 278.72 0.002 25.000 277.14 278.72 1.50 1.77 0.27 0.00 278.72 0.002 0.002 0.001 1.00 0.00 41 30 15.97 271.68 272.46 0.78* 1.31 12.16 0.54 273.01 0.000 25.000 272.52 273.87 1.35** 2.70 5.92 0.54 274.41 0.000 0.000 n/a 0.15 nla 42 24 13.39 272.62 274.10 1.48* 2.50 5.36 0.45 274.55 0.432 18.500 272.70 274.19 1.49 2.50 5.35 0.45 274.63 0.431 0.432 0.080 1.00 0.45 Project Pile: Storm Drain System 3.stm Number of lines: 42 Run Date: 1/10/2019 Notes: * depth assumed; ** Critical depth.; j -Line contains hyd. jump ; c = cir e = ellip b = box Storm Sewers v12.00 Storm Sewer Profile Elev. (ft) 295.00 288.00 281.00 274.00 267.00 Proj. file: Storm Drain System 3.stm N 25 50 75 HGL— EGL 295.00 288.00 281.00 274.00 267.00 260.00 100 125 150 175 200 225 250 275 300 Reach (ft) Storm Sewers Storm Sewer Profile Elev. (ft) 299.00 291.00 283.00 275.00 267.00 Proj. file: Storm Drain System 3.stm m N CO SCM C J pC J nC J O 50 HGL- 299.00 291.00 283.00 275.00 267.00 259.00 100 150 200 250 300 350 400 450 500 550 -- EGL Reach (ft) Storm Sewers Storm Sewer Profile Proj. file: Storm Drain System 3.stm Elev. (ft) 7 O CO — CO Iq -q-CD O r` ti r O N N N owww w >> > OS CONN Oto CO p r"NN N N N N o www m E» N > O 00 O h LOON N N o LU Fu E> 289.00 289.00 285.00 285.00 281.00 281.00 277.00 277.00 273.00 273.00 --- 0 269.00 269.00 0 10 HGL — EGL 20 30 40 50 Reach (ft) 60 70 Storm Sewers Storm Sewer Profile Proj. file: Storm Drain System 3.stm Elev. (ft) � p S O N N OOW� O N N N +O W W W @ j j C 05 W O N C 7 Os N OR'Tto CO to � CO00WW " N N N O W W W g E j j C E S S _ N � J O S �Nm 000000 M N N N O W W W .0 E>> C/) WEE N N C 00 N �� LO 0 M NW N N N W W 1=> A WE 302.00 302.00 298.00 298.00 294.00 294.00 290.00 290.00 1 286.00 Nit286.00 ° o ° 282.00 282.00 0 25 HGL 50 — EGL 75 100 125 Reach (ft) 150 175 200 225 Storm Sewers Storm Sewer Profile Proj. file: Storm Drain System 3.stm Elev. (ft) O a CO 4. �. O N— N p to UJ O N N N ) W W CuE to w s s O N -1 O S Opp N p V L CO avi CO CO N N N o Www in WE E CO N -' O ' LOO W M F - CO CO A N N o Ww to WE 298.00 298.00 295.00 295.00 292.00 292.00 289.00 289.00 286.00 286.00 283.00 o - o 47.824L4 24" 0 283.00 0 10 20 HGL—— EGL 30 40 50 60 Reach (ft) 70 80 90 100 Storm Sewers Storm Sewer Profile Elev. (ft) 322.00 313.00 304.00 295.00 286.00 277.00 0 Proj. file: Storm Drain System 3.stm 0 CO O S C O S J Q S J O S J _ Q 50 HGL 322.00 313.00 304.00 295.00 286.00 277.00 100 150 200 250 300 350 400 450 500 550 -- EGL Reach (ft) Storm Sewers Storm Sewer Profile Proj. file: Storm Drain System 3.stm Elev. (ft) 298.00 j O O O r- CO 0 000 CO CO CO O N N N p WWW C 7 —' O S N 0 00 CO CO Q N N N N W W W N •• 7 O 004 CO CO M N N N W W 298.00 294.00 294.00 290.00 290.00 286.00 282.000 286.00 282.00 __ 18"@4.02% 278.00 278.00 0 25 50 75 HGL— EGL 100 125 150 175 200 225 Reach (ft) 250 Storm Sewers Storm Sewer Profile Proj. file: Storm Drain System 3.stm Elev. (ft) 298.00 O C to OO CO (O O N N N +O w w w J OE LO V' �NO� V Ou" NNN o Www J O C O CO CO O CO N m NNN o www CO J 05 '� �rW r 0 0 0 N 00 00 00 NNN v Www LO CO O M— O N CO C, NN v ww 298.00 293.00 293.00 288.00 288.00 283.00 ----------- ----------- 283.00 278.00 6% 278.00 0OU-18"@5.12% 273.00 - o 273.00 0 50 HGL----- 100 150 EGL 200 250 300 350 400 Reach (ft) 450 Storm Sewers Storm Sewer Profile Elev. (ft) 297.00 291.00 285.00 279.00 273.00 267.00 0 Proj. file: Storm Drain System 3.stm 0 M V' 25 50 75 HGL — EGL 297.00 291.00 285.00 279.00 273.00 18" @ 2.08% 267.00 100 125 150 175 200 225 250 275 300 Reach (ft) Storm Sewers Storm Sewer Profile Elev. (ft) 303.00 298.00 293.00 288.00 283.00 278.00 0 LO N N N C J C J OE J O C Proj. file: Storm Drain System 3.stm CO N C 7 J O 303.00 25 50 75 — HGL— EGL 298.00 293.00 288.00 283.00 278.00 100 125 150 175 200 225 250 275 300 325 350 375 Reach (ft) Storm Sewers Storm Sewer Profile Elev. (ft) 307.00 301.00 295.00 289.00 283.00 277.00 0 Proj. file: Storm Drain System 3.stm r n C: J n c J 0 c J —O 25 50 75 HGL -- EGL 307.00 301.00 295.00 289.00 283.00 277.00 100 125 150 175 200 225 250 275 300 Reach (ft) Storm sewers Storm Sewer Profile Proj. file: Storm Drain System 3.stm OS ANN OHO.- OOCO OJ Elev. (ft) O N N N +, W UJ CO E > > in iY 5 lzr m O 0 N � ON O COCO O N N o w w m E> U) iY 5 299.00 299.00 1 295.00 295.00 291.00 291.0 287.00 287.0 283.0 283.00 _ o WE 279.00 279.00 0 HGL-- EGL 10 20 30 Reach (ft) Storm Sewers Storm Sewer Profile Proj. file: Storm Drain System 3.stm Elev. (ft) 299.00 O M CO 000 O00 I-� O N N N +, W W W CO E > > Chrrl- C? r-- Wer NNN WWW E » "T :t N NM OOW NNN M WWW .E » Cr) C 7 1 r0 N CO O m0 r N N M WW .�., E 299.00 294.00 294.00 289.00 289.00 284.00 284.00 _ __ _ i F7 279.00 279.00 IP 6 @ 0 p.ou -18"@2.04% 274.00 274.00 0 25 50 75 HGL EGL 100 125 150 175 200 225 250 275 300 325 350 Reach (ft) 375 400 Storm Sewers Storm Sewer Profile Proj. file: Storm Drain System 3.stm Elev. (ft) 292.00 7 O M r -co O) 6) OCO O N N N owww mE>> v)WSS M 7 J O M LO MCO O N N N o Ww CO E> 292.00 289.00 289.00 286.00 286.00 283.00 283.00 280.00 25.50 - 280.00 277.00 0 10 HGL 20 30 40 50 EGL Reach (ft) 277.00 60 70 80 Storm Sewers Storm Sewer Profile Proj. file: Storm Drain System 3.stm Elev. (ft) O CO NMS O N N N N O +o w w w mE>> <n c c J OS 0 OMM U.) toLO '7 N h I� � NNN o www c E» (n w E5 CO M J 05 0 00 cD cD W � CN o Www CO 65 R-- M M J O on OV O O W r. � NN o ww U) W- 293.00 293.00 289.00 289.00 285.00 285.00 281.00 281.00 277.00 277.00 0 An QM]f 273.00 273.00 0 10 20 HGL------- EGL 30 40 50 60 70 Reach (ft) 80 90 100 Storm sewers Storm Sewer Profile Elev. (ft) 298.00 294.00 290.00 286.00 282.00 278.00 0 N CO G 1:5 n C J O.E Proj, file: Storm Drain System 3.stm 25 50 HGL -- EGL 75 294.00 290.00 286.00 282.00 278.00 100 125 150 175 200 225 250 275 Reach (ft) Storm Sewers Storm Sewer Profile Proj. file: Storm Drain System 3.stm Elev. ft () O S N CR O N N N o W W W B E>> U)WEE ,2 O CO NMS N N N N_NN O W W W mE» U) �cc N _ C 7 -1 0E O O�iij O NNN 00 r WWW :° E>> C/) Tcc M C 'i OS CO C,CO O) 00 00 CO CO NNN CO _ WWW E>> Cn WEE M 7 00 O to o CO CO C's O NN +_ WW �o E> N WE 301.00 301.00 295.00 295.00 289.00 289.00 283.00 283.00 277.00 0 277.00 271.00 271.00 025 50 HGL------- EGL 75 100 Reach (ft) 125 150 175 200 Storm Sewers 1 TMERENGERING Skimmer Sediment Basin Project: Publix Skimmer Basin 1 Location: Flowers Planttion Date: 17 -Dec -18 Basin ID: Sediment Basin 1 Area Disturbed Runoff Area Runoff Coefficient Intensity (10 Year) Q10= Basin Volume Calculation: Volume of Sediment= '.111x'. 8.92 0.35 7.38 23.04 5.03 Acres 9,054 dCF Inch / Hr CFS X 1,800 CF Sediment / Year Surface Area Calculation: Surface Area = Q10 X 325 SF/CFS 23.04 CFS X 325 SF/CFS 7,488 SF Sediment Basin Sizinq: Bottom of Basin 110 Length Top of Basin 120 Length Sediment Basin Area: Sediment Basin Volume At a 2 :1 slope 55 Width 1 0 Depth 65 Width 2.5 Depth 7,800 SF 17,313 CF Weir Design and Velocity Check: Weir Length= 1 25 Feet Height of Water over Weir= 1 0.49 Feet Velocity Check: 1.88 FPS Skimmer Sizing: Days to Drain = 3 Days Skimmer Size = 2 Inches Orifice Size = 1.9 Inches TMERENGERING Skimmer Sediment Basin Project: Publix Skimmer Basin 2 Location: Flowers Planttion Date: 17 -Dec -18 Basin ID: Sediment Basin 2 Area Disturbed Runoff Area Runoff Coefficient Intensity (10 Year) Q10= Basin Volume Calculation: Volume of Sediment= X� 6.45 0.35 7.38 16.66 6.45 Acres 11,610 dCF Inch / Hr CFS X 1,800 CF Sediment / Year Surface Area Calculation: Surface Area = Q10 X 325 SF/CFS 16.66 CFS X 325 SF/CFS 5,415 SF Sediment Basin Sizinq: Bottom of Basin 90 Length Top of Basin 100 Length Sediment Basin Area: Sediment Basin Volume At a 2 :1 slope 45 Width 1 0 Depth 55 Width 2.5 Depth 5,500 SF 11,938 CF Weir Design and Velocity Check: Weir Length= 1 20 Feet Height of Water over Weir= 1 0.46 Feet Velocity Check: 1.82 FPS Skimmer Sizing: Days to Drain = 3 Days Skimmer Size = 2.5 Inches Orifice Size = 2.0 Inches TMERENGERING Skimmer Sediment Basin Project: Publix Skimmer Basin 3 Location: Flowers Planttion Date: 17 -Dec -18 Basin ID: Sediment Basin 3 Area Disturbed Runoff Area Runoff Coefficient Intensity (10 Year) Q10= Basin Volume Calculation: Volume of Sediment= OW 2.98 0.35 7.38 7.70 2.98 Acres 5,364 dCF Inch / Hr CFS X 1,800 CF Sediment / Year Surface Area Calculation: Surface Area = Q10 X 325 SF/CFS 7.70 CFS X 325 SF/CFS 2,502 SF Sediment Basin Sizinq: Bottom of Basin 60 Length Top of Basin 70 Length Sediment Basin Area: Sediment Basin Volume At a 2 :1 slope 30 Width 1 0 Depth 40 Width 2.5 Depth 2,800 SF 5,750 CF Weir Design and Velocity Check: Weir Length= 1 10 Feet Height of Water over Weir= 1 0.44 Feet Velocity Check: 1.77 FPS Skimmer Sizing: Days to Drain = 3 Days Skimmer Size = 2 Inches Orifice Size = 1.4 Inches }Nto porA13 Ik use Ftc OrZ6 g.© TLC" L�2yc�Tt1 -r F-: t -Z-•101 kNaw t`1 - Sys 1 t 5 cFs �x5 qA F�5 5o r V'I z r KE3 " rZCP * QSr. CLA55 fit? QAC' wc--k M iZAVI lqo N 18" v,u DE PTA , # USS rlt;urz9 S.Gr6 `L �( ''tccP • �ZS = � z. sz F"�s Mir -b _ i�Q• 3 gJ Zq USE �tk55 � fzLF iZiMl, Om�c� wi 4RAn I LIp �d LI '` i" Channel Report Hydraflow Express Extension for Autodesk@ AutoCAD® Civil 3D® by Autodesk, Inc. Drainage Ditch - Bare Soil Triangular Area (sgft) Side Slopes (z:1) = 3.00, 3.00 Total Depth (ft) = 5.00 Invert Elev (ft) = 100.00 Slope (%) = 1.10 N -Valle = 0.020 Calculations Compute by: Known Q Known Q (cfs) = 115.00 Tuesday, Jan 1 2019 Highlighted Depth (ft) = 2.19 Q (cfs) = 115.00 Area (sgft) = 14.39 Velocity (fus) = 7.99 Wetted Perim (ft) = 13.85 Crit Depth, Yc (ft) = 2.47 Top Width (ft) = 13.14 EGL (ft) = 3.18 Elev (fit) Section Depth (ft) 6.00 106.00 105.00 5.00 4.00 104.00 3.00 103.00 102.002.00 1.00 101.00 0.00 100.00 99 00 -1 00 -- 5 10 15 20 Reach (ft) 25 30 35 40 Channel Report Hydraflow Express Extension for Autodesk@ AutoCADO Civil 3DO by Autodesk, Inc, Drainage Ditch - Grassed Triangular Area (sqft) Side Slopes (z:1) = 3,00, 3.00 Total Depth (ft) = 5.00 Invert Elev (ft) = 100.00 Slope (%) = 1.10 N -Value = 0.035 Calculations Compute by: Known Q Known Q (cfs) = 115.00 Elev (ft) 106.00 105.00 104.00 103.00 102.00 101.00 100.00 99.00 0 Section Tuesday, Jan 1 2019 Highlighted Depth (ft) = 2.71 Q (cfs) = 115.00 Area (sqft) = 22.03 Velocity (ftls) = 5.22 Wetted Perim (fit) = 17.14 Crit Depth, Yc (ft) = 2.47 Top Width (ft) = 16.26 EGL (ft) = 3.13 5 10 15 20 Reach (ft) 25 30 35 Depth (ft) 6.00 5.00 4.00 3.00 2.00 1.00 0.00 -1.00 40 (Dta- v33 I �— c,,- 4E25 L- I- - - F�d�C��GS l c] l.w.i r L11CkS ^ � �' Y'Z 5 � � 4`l �'t G CL G I� j `• L7 � Z 1 cm T --Zs PIC Q -� 0--554 g . Zl * 8,!51A,- = 2 Q. tI 5cf" Q = ZN. ScFs StUPE = 2,6% a - 8.z l = S.g l hG D3S E3•ZI `k 5,91 AL [ �Itb cfs SLI -,9E: = TD 3 A e� C)53S IzS= B-ZI N- o,3s ac o,3Snc - 1.01 +-r-s -'D 621 I\= 2.67 ^1- QY O 3s 8.Z1 Z.GZAC. = -7• 53cF.s G1= �• S � c�S St-ooc � 2.39d I Channel Report Hydraflow Express Extension for AutodeskO AutoCA❑O Civil 3D@ by Autodesk, Inc TD 1 - Bare Soil Triangular Side Slopes (z:1) = 2.00, 2.00 Total Depth (ft) = 2.00 Invert Elev (ft) = 100.00 Slope (%) = 2.60 N -Value = 0.020 Calculations Compute by- Known Q Known Q (cfs) = 24.45 Tuesday, Jan 1 2M Highlighted Depth (ft) = 1.24 Q (cfs) = 24.45 Area (sqft) = 3.08 Velocity (ftls) = 7.95 Wetted Perim (ft) = 5.55 Crit Depth, Yc (ft) = 1.57 Top Width (ft) = 4.96 EGL (ft) = 2.22 Elev (ft) Section 103.00 102.50 102.00 101.50 101.00 -- 100.50 100.00 99.50 1 2 3 4 5 Reach (ft) 0 7 8 9 Channel Report Hydraflow Express Extension for Autodesk(D AutoCADO Civil 30@ by Autodesk, Inc TD 1 - Grassed Triangular Side Slopes (z:1) = 2.00, 2.00 Total Depth (ft) = 2.00 Invert Elev (ft) = 100.00 Slope (%) = 2.60 N -Value = 0.035 Calculations Compute by: Known Q Known Q (cfs) = 24.45 Elev (ft) Section 103.00 102.50 102.00 101.50 101.00 100.50 100.00 99.50 1 2 3 4 Tuesday, Jan 1 2019 Highlighted Depth (ft) = 1.52 Q (cfs) = 24.45 Area (sqft) = 4.62 Velocity (ft/s) = 5.29 Wetted Perim (ft) = 6.80 Crit Depth, Yo (ft) = 1.57 Top Width (ft) = 6.08 EGL (ft) = 1.96 5 6 Reach (ft) 7 8 9 Channel Report Hydraflow Express Extension for Autodesk® AutoCAD® Civil 3D@ by Autodesk, inc TD 2 - Bare Soil Triangular Side Slopes (z:1) = 2.00, 2.00 Total Depth (ft) = 2.00 Invert Elev (ft) = 100.00 Slope (%) = 1.90 N -Value = 0.020 Calculations Compute by: Known Q Known Q (cfs) = 16.98 Elev (ft) 103.00 102.50 102.00 101.50 101.00 100.50 100.00 99.50 0 Section Tuesday, Jan 1 2019 Highlighted Depth (ft) = 1.14 Q (cfs) = 16.98 Area (sgft) = 2.60 Velocity (ftls) = 6.53 Wetted Perim (ft) = 5.10 Crit Depth, Yc (ft) = 1.35 Top Width (ft) = 4.56 EGL. (ft) = 1.80 Depth (ft) 3.ao 2.50 2.00 1.50 1.00 0.50 0.00 -0.50 8 9 10 1 2 3 4 5 Reach (ft) 6 7 Channel Report Hydraflow Express Extension for Autodesk® AutoCAD® Civil 3D® by Autodesk, Inc. TD 2 - Grassed Q (cfs) Triangular Area (sqft) Side Slopes (z:1) = 2.00, 2.00 Total Depth (ft) = 2.00 Invert Elev (ft) = 100.00 Slope (%) = 1.90 N -Value = 0.035 Calculations Compute by- Known Q Known Q (cfs) = 16.98 Tuesday, Jan 1 2019 Highlighted Depth (ft) = 1.41 Q (cfs) = 16.98 Area (sqft) = 3.98 Velocity (ftls) = 4.27 Wetted Perim (ft) = 6.31 Crit Depth, Yc (ft) = 1.35 Top Width (ft) = 5.64 EGL (ft) = 1.69 Elev (ft) Section Depth (ft) 3.00 99 103.00 ----- - - 2.50 - — _ 102.50 102.00 - - 2.00 1.50 - -.. - - - -- -- - - 101.50 1.00 - — 101.00 0.50 100.50 0-00 100.00 50 - - -050 1 2 3 4 5 6 Reach (ft) 7 8 0 10 Channel Report Hydraf low Express Extension for AutodeskOAutoCAD® Civil 3D® by Autodesk, Inc. TD 3a - Bare Soil Q (cfs) Triangular Area (sgft) Side Slopes (z:1) = 2.00, 2.00 Total Depth (ft) = 2.00 1 nvert Elev (ft) = 100.00 Slope (%) = 3.21 N -Value = 0.020 Calculations Compute by: Known Q Known Q (cfs) = 1.01 Tuesday, Jan 1 2019 Highlighted Depth (ft) = 0.36 Q (cfs) = 1.010 Area (sgft) = 0.26 Velocity (fYs) = 3.90 Wetted Perim (ft) = 1.61 Crit Depth, Yc (ft) = 0.44 Top Width (ft) = 1.44 EGL (ft) = 0.60 Elev (ft) Depth (ft) Section 3.00 103.00 2.50 102.50 2.00 102.00 1.50 101.50 - - 1.00 _ 101.00 0.50 100.50 0.00 100.00 99 50 -- -050 1 2 3 4 5 6 Reach (ft) 7 8 9 10 Channel Report Hydraflow Express Extension for Autodesk®AutoCAD& Civil 3DO by Autodesk, Inc. TD 3a - Grassed Q (Cfs) Triangular Area (sqft) Side Slopes (z:1) = 2.00, 2.00 Total Depth (ft) = 2.00 Invert Elev (ft) = 100.00 Slope (%) = 3.21 N -Value = 0.035 Calculations Compute by: Known Q Known Q (cfs) = 1.01 Elev (ft) Section 103.00 102.50 102.00 101.50 101.00 100.50 100.00 oa r1n 1 2 3 4 Tuesday, Jan 1 2019 Highlighted Depth (ft) = 0.45 Q (Cfs) = 1.010 Area (sqft) = 0.40 Velocity (ftls) = 2.40 Wetted Perim (ft) = 2.01 Crit Depth, Yc (ft) = 0.44 Top Width (ft) = 1.80 EGL (ft) = 0.55 5 6 Reach (ft) 7 8 9 Depth (ft) 3.00 2.50 2.00 1.50 1.00 0.50 0.00 -0.50 Channel Report Hydraflow Express Extension for Autodesk® AutoCADO Civil 317® by Autodesk, Inc. TD 3b - Bare Soil Q (cfs) Triangular Area (sgft) Side Slopes (z:1) = 2.00, 2.00 Total Depth (ft) = 2.00 Invert Elev (ft) = 100.00 Slope (%) = 2.30 N -Value = 0.020 Calculations Compute by: Known Q Known Q (cfs) = 7.53 Tuesday, Jan 1 2019 Highlighted Depth (ft) = 0.82 Q (cfs) = 7.530 Area (sgft) = 1.34 Velocity (ftls) = 5.60 Wetted Perim (ft) = 3.67 Crit Depth, Yc (ft) = 0.98 Top Width (ft) = 3.28 EGL (ft) = 1.31 Elev (ft) Section Depth (ft) 3.00 103.00 - 2.50 102.50 2.00 --- 102.00 1.50 101.50 - 1.00 101.00 - 0.50 100.50 0.00 100.00 99 50 -0.50 1 2 3 4 5 6 Reach (ft) 7 8 9 10 Channel Report Hydraflow Express Extension forAutodeskp AUtoCADO Civil 3D® by Autodesk, Inc. TD 3b - Grassed Q (cfs) Triangular Area (sgft) Side Slopes (z:1) = 2.00, 2.00 Total Depth (ft) = 2.00 Invert Elev (ft) = 100.00 Slope (%) = 2.30 N -Value 0.035 Calculations Compute by: Known Q Known Q (cfs) = 7.53 Tuesday, Jan 1 2019 Highlighted Depth (ft) = 1.01 Q (cfs) = 7.530 Area (sgft) = 2.04 Velocity (ftls) = 3.69 Wetted Perim (ft) = 4.52 Crit Depth, Yc (ft) = 0.98 Top Width (fit) = 4.04 EGL (fit) = 1.22 Elev (ft) Section Depth (ft) 103.00 102.50 3.00 102.00 101.50 2.50 2.00 101.00 100.50 1.50 1.00 104.00 -- -- - - � 0.50 99.50 0.00 -050 --.--- --- 1 2 3 4 5 6 Reach (ft) 7 8 9 10 ty 42 LQ MH53 P S _ ' i r_�_�=_��� P 1_1- ED ">' --- - --- \-=�.�--� '�- + O i mm moo"-- __ --__ }-- _!-~+ r+++——.%._r --===--.�-==Y _ \ \ - -- �~~ + DIGITI \�� S4 m� �o ______ --- 14 Q + _5J z Ft G 10 # o'er = Si�__= _AKE LI `�� C 42 \ W N�Nl_ ;_ : Y _ � = - R 1 }+ is \ \ \ \\ ; \ I I 1 \ ♦`\��` \1 -- f' _-'_- _ Q - -' 1 _�'� ~= -- _! � -- ��� ��..:��----= I G 129 i l \ \\ ♦ \ \... 4 \_ --�\ \\\ PONA 5�A10 p5. 1 __ _��- - f /'�_ --�..x� ===- / / 1 f r y^ �1 \ \ \ \ \ \-__ \ \ \ \♦ I �-f-f- LEV• 3 - � �-��-`r��' / a �i 1 1 \\ j I 1 � i POND IN 1 r \ \ c \ \ �\ \ \ EROSION LEGEND '- - •! C • - _'ao -3Q5_ 29 1 1\ \ \\`` `\`` ,`�\\\\ \ \\\\ \\� \\ \ \ !•--F� SILT FENCE NN `N— _ ' ■-�■ SILT FENCE OUTLET \\ \\ \ \\ \\ \ \ \\ \\ \'' r' CONSTRUCTION ENTRANCE 300 _ / 29j _�- \ 71 / - / / / ` \ ■ - _ _ _ _ 1 1 r \ \ \ 1 \ \<l'J \ ` PERMANENT SEEDING / •/ i✓ _' /' // ■ 1 - t rL,fi '�-° �— ` • J r• \III` !!a \\ \\ \ \ / y 1 \ 1 1 \\ 11 / `TaF�L � / / _ _ + _ - 1 - _ ! _ / / 9 , ! t I = ■ r ■ r 1 \ \\ \\ 1 11 1 \I \ 1 \ I \ \ \ z � TD �TD TEMPORARY DNERSION / / l 1 _ • _ AC; - _ ■ . SIL T I / 1 \ \ \ , W/ NAG D875 EXCELSIOR MATTING \ / / / /' �' / / • • " ~ ~ $g \ - FENCEIj r I ! }1 \1 (� i.--295--� `'-~ -- �- _ . 9 \ } ,OUTLET \ , /ry /� / , 1 1 1 f 1 I \ � E] I SKIMMER SEDIMENT BASIN / al �C` �; 1 f - • ;�' V� - - �' ala l f \ I / .1 - ll 4 - _ • _ - -� ~ - _ - - _ - �_ > I 1 } r / 1 I , . • TOTAL AREA DISTURBED - 17.75 Ac. •\l ' /' _`i +`' - - 290 • ! `.I,I. �' i 1 �g5� ■ l • - / r - - _ - \ - ` _ - +� r ■ • ■ i j /` / / / // 1 1 k,� ARC FILTER INLET PROTECTION — 1 / sILr1 1/ / I,. // // 11 , 1 FENCE � � \ \ � � _ f � / ) � \ s TRUCK WASHOUT l i 1 >1 1 ► ! o� _ ¢ - r�P \ r�- \ } 1 OUTLET Iry 1 -29 � , \ \ 1 \ -- �-F` NCDOT WATTLE / 1 1 1 1' V /� _ '► 29 A • 1 1, 1 1 d •. // 1 • ...TrI CLASS B OUTLET PROTECTION ly I \� 1 �, /I / J _t - , • ''2�a _ r" 291 y \ \ ,1 1 \ \ 1 \\ \ \I t 1 \\ `\ EXCELSIOR MATTING 1 1\\ I 1 ti 1 / l 2 _ / —�P i p ` \• \ 1 ,�/ { \ \\ 1` I / 1\ E \\ \\ \ \ (NACU 75, 6' WIDE) • i \\y, ! _ � ,- ~ J : �. • /I I / \ f i i 1/I/ // / �/ �� DENTIA4 \\ /-. \ ~ \ � HARDWARE CLOTH • } / r / 1 � �� I f 1 1 I 1 / / VE OPMEN� � 1 \ \\ \ - ■ ■ � INLET PROTECTION 1 , \: ♦ 1�_ :- � \\.\\.\ Torr • Ni } i \\\ \ o / / I \ \ \� \ \ U l + $ ox\ T ~` sa S. 04III r / / \ \� \ \ \ AW 2 1 2 ` � � ■ �..rr l / jr • 4 \ I \ 1 ! 9 - ~ TOP LENGTH ;-..:100 70P- . , .90 7TOAM4 07roM •\ \\ \\ \\ 1 , I 3 ��� BASK DEPTH x,12,5 1 I \ 1 1 w X90 SKIMMER SIZE _ 2.5 • _ Q • ; 1 2 / 1\ \ \ 1 1 1 1 \ \ 1 } \ 1. �7O' ♦ i r 1 ` � _ Is ' \� %' N , 3,.1- r / 1 1 ti \ \ 1 } 1 } ` 1 1 �i \ \ ,� 2 .■■ 1 � // / �\ 1 1 11 ii 1 1 Coot lfff#5 7 SEDIMEAI BASIN 1 I l \�� ` f .'r s+� / \ • r 1 , s - y� 1, . - -Tt7P LENGTH 70 QI41FlCE SIZE = 1.4 \ I o f / ,� "_ x • < ■ 4 �r1a TOP WIDTH - 40 WE7'R WIDTH - 10, 1 I 1 �128� , - .. ■ p� BOTJW LENGTff =�i`0� WEIR DEPTH =05' II 1 1SeBENS �iN S • \ \ I \ y I Q IMM922"I BASIN� . ♦ N. �A_ c7 - - -BOTTOM WIDTH = JO -BAFFLES - 3 1 I � � \ \ \ . ¢ \ S 04 I 1 1 1 \ \ t 2 \ 1 TOP �WDTHH — 1 \ \ _ _ `� _ �' - ,, BASIN_DEPJH. _ --2.5' SIDESLQPES = 21 TSP WIDTH = 65 \\ \\ `\ _ - \ - - 1 SKIMMER SIZE =2"' _ - - I I I // / / 1 \ \ \ \ \ \ t i t • \ \ ,BOTTOM` LENGTH = 1� \ '77 \ \\ \\ \ \ \ 1\ 1 , I \ t 1 \ \ BOTTOM WDTH = 5.5 ` \ \ \ \ 1 \ BASIN DEPTFI s 25 �- j h --- - \\ • \` \\\\ \�\\ \ \ \\ \ \ 1 ��\ ` \\ `'`� SKIMMER SIZE s '2., ' ti� rye` \ � \ S& CE y� S 2g0� \• \ \ \ \ \ \ kr4 ` ORIRCE SIZE - 1 fn \ \ c✓�, 5 - r _ _ - - _ / ...v "W"11 f 1 \! \• \ \\ \ \\ \ \ $ `\ WFJR\WDTH - 25' \ ' \ 1';s;�, s \ Oil T:S -_-- ,�- ___ ~�-__ ---Woo �' , 1 \\ MUR DEP7H =0.5' \� \\ \ F�� - \\ \ 2�� �- _ _ �� _ _f 1 11 \ BAFFLE) �'� 1 �\ \'JD" G \ \ = `. — — ~ _ — — _ ` ` ~ - 2gt7 �/ 1 if < f � SIDESLOPES - 1: 1! �\ • h• \\ * %All ___-_ �I`���~✓`" / ti ~ � / ►� I J i / • \ \ \�\ \\ \ \ -285- 9- _� \NIP � t \ \ \ \ � \ \ \ \ � • \ � \ \ /' R \ \ � — ~ � fie- .�C `�' - _` i� / / � 1-1 }} �i i j , , —. \\ \'•`1 \\ \ \ — ` \` \ \� \ - \ LT �\ .,\ — � � i -- / n C'/ / � f illi / I ,/ ' / / / `- � - \•\\ FENCE \ \\ ^� \` \� i \ \ 4 c ✓ ` =/ /`/ ' 111 / / / / / // / % OUTLETS \ \7*\ A X\\ \ \ \ \ \ \\ \\ \\ �� \\ \ \ ♦ = v_ _ — /�// ,' / \_ !lir 1 // .r. r. s-� 1 Il \ y\• *� $\,� I ' y '\ `► 1` 1 \ \ \ `sem \ i 1 rza° \ 1 \ \ \ \ \ \ _ _ _ z . ! 1 1 r / 1 1 \ \ �� I 1 \ 1 1 ♦ \ \ \ 1 \ \ \\ \j \ \ -26S, i \'IN� \ \ \\ �~ �—�! _�� — \ / /J r /~— J / /f / 1 �- _/x/ j j/ AVS f 1 \ \ / \\ \ �2� \ \ \ \ \\\ \\\\ \\ / r ~ \y`\\ ` \� `/ / ,?6`� 0 l� ✓✓ // / / 7/- SILT _461 • 1 } y \ \ / \ \ \ 0` \ \ \ \ \ \ \ ` ~ !1-T •L 1 / / / > / _ \\y 1 l 1 1 \ 1 FENCE / / 1 \ \ \ \ \ \ \ ♦ \\ \ \ \ 1 OUET TL / /� 1 ` — • / / - / - % i Notification -of -Land -Resources Sediment and Erosion Control Self Inspection Program: The Sedimentation Pollution Control Act was amended in 2006 to require persons responsible for land disturbing activities inspect a project after each phase of the project to make sure that the approved erosion and sedimentation control plan is being followed. Rules detailing the documentation of these inspections took effect October 1, 2010. To simplify documentation of Self–Inspection Reports and NPDES Self–Monitoring Reports, a combination form is now availible. The new form was developed to satisfy the requirements of the Sedimentation Pollution Control Act and the NPDES Stormwater Permit for Construction Activities, NCG 010000. Beginning August 1, 2013, the Division of Energy, Mineral, and Land Resources is responsible for administering both the SPCA and the NPDES Stormwater Permit for Construction Activities, NCG 010000. The combined form should make it easier to comply with self–inspection requirements. The Combined Self–Monitoring form is avolible as a PDF and Word document from the Land Quality web site, ltff//oortal.ncdenr.orq/y r/erosion If you have questions, please contact the Land Quality Section at a DENR Regional Office. 0 60 1 - / 1 1 ! - , - ■ 1 tl I f / { i 11 \\ 1\ -_ \\ \\ \ 1 1\ \\ \ \ \ \ \\ \\ -_=_.i�// C till /- ♦ f { /—■ ■+I Y l� I 1 I / 1 \ \ \ — \ \ \ 1 1 \ \ \\ NN \\\ \\\\` 1-`i\t` fA — _ ~'�� `Awkii \ FENCE'/ - NN N, N,gum NN \\ \ . NI NN NI \ \ \ \ \ \ \ \� — — \ \ \ \ \ \ \ 2 NN NN \ SCALE, 1' = 60' \ \ \ \ \ \ \ \ \ �` —~_ �` \� \` �` \ \ \ 6S\ \ \ \ \ \ \ \ \\\ \ 21- \ NN I\\\\ "I � 120 150 180 210 240 \ �� \ \ \ �. `� `� —� �� �. \� \ \ \ \ \ \ \ \ \ \ \ \ . \ ,� \ C \\ �� �� AND THE ANGEL SAID TO THEME, "FEAR NOT: FOR BEHOLD, I BRING YOU GOOD TIDINGS OF GREAT JOY, WHICH SHALL BE TO ALL PEOPLE. FOR UNTO YOU IS BORN THIS DAY IN THE CITY OF DAVID A SAVIOR, WHO IS CHRIST THE LORD. LUKE 2: 10-11 Q0) ri00 XI O� co It O N ti N w z O x IZ �10 HORZ. SCALE: 1"=60' VERT. SCALE: NONE c3 z r� or w V w z z Z z w `n Y U Ex E O W� >� LL 3 WU rn zCO O `n 0 IN z ++w v �z Z �w W �' o¢ 00 BLN—C-1-874 1 EROSION CONTROL PLAN REVISIONS FILE NO. 2018-033 HORZ. SCALE: 1"=60' VERT. SCALE: NONE CE -09 • ENGINEERING Designing the Future... Today! Thursday, January 14, 2019 Karen Higgins NCDEQ Stormwater Engineering 1617 Mail Service Center Paleigh, NC27699 Publix @ Rowers Plantation Dear Mrs. Higgins: Induded in this package is the Stormwater Management Ran for Publix @ Rowers Rantation. I have included two (2) plans sets for Publix @ Rowers Rantation along with two (2) sets of calculations. Induded in those calculations is the signed Operation and Maintenance Agreement for the Wet Detention Pbd that will provide directions to assist with maintenance as well as guidelinesto remediate issuesthat mayarise around the Wet Detention Pbnd including around the entire BMP, the perimeter of the BMP, the inlet device, the forebay, the vegetated shelf, the main treatment area, the embankment, the outlet device and the receiving water. Sincerely, Ethan Averette Stocks Engineering, RA J. Michael Stocks, PE 252.459.8196 (voice) 801 East Washington St. 252.459.8197 (fax) PO Box 1108 252.903.6891 (mobile) Nashville, NC 27856 mstocksna stocksengineering.com