Loading...
HomeMy WebLinkAboutNC0067288_Inspection_20190226EPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NC0067288 19/02/11 S T31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Hunter's Glen WWTP US Hwy 64 Etowah NC 28729 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 09:00AM 19/02/11 16/02/01 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Vincent L Edwards/ORC/828-697-3077/ Other Facility Data 11:45AM 19/02/11 20/11/30 Name, Address of Responsible Official/Title/Phone and Fax Number Patty Carland,117 Kira Ln Hendersonville NC 28739//828-890-4810/Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports Self-Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date Linda S Wiggs ARO WQ//828-296-4500 Ext.4653/ Daniel J Boss ARO WQ//828-296-4658/ Timothy H Heim ARO WQ//828-296-4665/ Mikal Willmer Division of Water Quality//828-296-4686/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 DocuSign Envelope ID: FC9523A4-7002-40C0-A3D7-D790300D6907 2/26/2019 2/26/2019 2/26/2019 2/26/2019 2/26/2019 NPDES yr/mo/day 19/02/11 Inspection Type S3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) I, Daniel Boss, met with Vince Edwards, ORC, for a Compliance Sampling Inspection at Hunter's Glen WWTP on 2/11/2019 at 9:00am. Chris McHugh (EPA inspector), Mikal Willmer (DWR), Tim Heim (DWR), and Linda Wiggs (DWR) were also present for the inspection. Overall the plant seemed to be operating very well and samples indicate an effluent within permit limits. Vince Edwards and Chris McHugh set up separate composite samplers for flow proportional sampling. The EPA's sampler began sampling at approximately 11am on 2/11/2019 and ended at 10:30am on 2/12/2019 and Mr. Edwards had a similar time period for his composite sample. I took samples for analysis of BOD and TSS from both composite samples. Sample Analysis Results: EPA Sampler- 13 mg/L BOD, 14 mg/L TSS Facility Sampler- 13mg/L BOD, 15 mg/L TSS Mr. McHugh mentioned that the position of the transducer for the WWTP's flow meter should be closer to the water level and farther back from the weir plate. Mr. McHugh also mentioned that the facility's sampling jug should be elevated higher than the sampling point. The weir plate also seems to be to small since the plant flow sometimes rises above the top of the V-notch. The influent pump station control needs an audio alarm. The visual alarm and the autodialer were both working. The air flowing to the digester was restricted and not adequate to mix or aerate the sludge. NC0067288 17 (Cont.) Page#2 DocuSign Envelope ID: FC9523A4-7002-40C0-A3D7-D790300D6907 Permit:NC0067288 Inspection Date:02/11/2019 Owner - Facility: Inspection Type: Hunter's Glen WWTP Compliance Sampling Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Settleable solids, DO analyzed every couple monthsComment: Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain-of-custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Page#3 DocuSign Envelope ID: FC9523A4-7002-40C0-A3D7-D790300D6907 Permit:NC0067288 Inspection Date:02/11/2019 Owner - Facility: Inspection Type: Hunter's Glen WWTP Compliance Sampling Record Keeping Yes No NA NE Facility has copy of previous year's Annual Report on file for review? There were two typos on the DMRs that were reviewed, they did not make any difference in terms of compliance. Comment: Pump Station - Influent Yes No NA NE Is the pump wet well free of bypass lines or structures? Is the wet well free of excessive grease? Are all pumps present? Are all pumps operable? Are float controls operable? Is SCADA telemetry available and operational? Is audible and visual alarm available and operational? There is no audio alarm, but there is an auto-dialer.Comment: Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? Are surface aerators and mixers operational? Are the diffusers operational? Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin’s surface? Is the DO level acceptable? Is the DO level acceptable?(1.0 to 3.0 mg/l) The basin DO measured 4.6 mg/L. The settleability of the sludge was 17% in 30 minutes. Basins are operated at a time sequence of 45 min on and 15 min off. Comment: Pumps-RAS-WAS Yes No NA NE Are pumps in place? Are pumps operational? Are there adequate spare parts and supplies on site? RAS/WAS pumps are air lift pumps.Comment: Secondary Clarifier Yes No NA NE Page#4 DocuSign Envelope ID: FC9523A4-7002-40C0-A3D7-D790300D6907 Permit:NC0067288 Inspection Date:02/11/2019 Owner - Facility: Inspection Type: Hunter's Glen WWTP Compliance Sampling Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately ¼ of the sidewall depth) There are 2 clarifiers in series, the final clarifier had a blanket of 1' of 9'. The initial clarifier had a blanket of 3' of 8' depth. Comment: Aerobic Digester Yes No NA NE Is the capacity adequate? Is the mixing adequate? Is the site free of excessive foaming in the tank? # Is the odor acceptable? # Is tankage available for properly waste sludge? The air flowing to the digester was restricted and not adequate to mix or aerate the sludge. The digester is pumped out about 3 times per year according to Mr. Edwards. Comment: Disinfection-Tablet Yes No NA NE Are tablet chlorinators operational? Are the tablets the proper size and type? Number of tubes in use?3 Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de-chlorination? Comment: De-chlorination Yes No NA NE Type of system ?Tablet Page#5 DocuSign Envelope ID: FC9523A4-7002-40C0-A3D7-D790300D6907 Permit:NC0067288 Inspection Date:02/11/2019 Owner - Facility: Inspection Type: Hunter's Glen WWTP Compliance Sampling De-chlorination Yes No NA NE Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de-chlorination substance stored away from chlorine containers? Comment: Are the tablets the proper size and type? Are tablet de-chlorinators operational? Number of tubes in use?2 The Total Residual Chlorine measured less than 10 ug/L post dechlorination.Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? The flow meter program setup was incorrect. The meter was programmed for a 45 degree v-notch weir, but the weir is actually a 30 degree v-notch. This was corrected in the programming during the inspection. Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? The effluent pipe is partially submerged.Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Page#6 DocuSign Envelope ID: FC9523A4-7002-40C0-A3D7-D790300D6907 Permit:NC0067288 Inspection Date:02/11/2019 Owner - Facility: Inspection Type: Hunter's Glen WWTP Compliance Sampling Effluent Sampling Yes No NA NE Thermometer in sampler appeared to not be reading correctly. The ORC said he would fix/replace the thermometer. Mr. McHugh discovered that the flow meter was not programmed correctly and fixed the problem onsite. The meter was reading as if the facility used a 45 degree v-notch weir, when in fact the v-notch weir was 30 degrees. Mr. McHugh also recommended moving the sampler to a position at the plant where it would be elevated above the level of where the sample is being drawn from. Finally Mr. McHugh suggested a better position for transducer, farther back from the weir plate and at an elevation nearer to the wastewater. The weir plate appears to be to small for accurate flow measurement since the plant flow sometimes goes above the top of the V-notch. Comment: Page#7 DocuSign Envelope ID: FC9523A4-7002-40C0-A3D7-D790300D6907