Loading...
HomeMy WebLinkAboutNC0021474_Pretreatment Annual Report_20190225 0/7 eai'ce February 15,2019 Vivien Zhong Environmental Engineer NC DWR-PERCS 1617 Mail Service Center Raleigh,North Carolina 27699-1617 RE: 2018 PAR—City of Mebane Dear Ms.Zhong: Please find enclosed two copies of the City of Mebane's Pretreatment Annual Report for January— December 2018. If you have any questions,please do not hesitate to contact me at 919-304-9217.Thank you for your continued cooperation and oversight in the implementation of the City of Mebane's Pretreatment Program. RECEIVED/DFNPJDWR Sin erely, _ FEB 2 5 2019 NaUj. Water Resources Amy rinoski Permitting Section Compliance Manager Cc: Dennis Hodge,Water Resources Director-City of Mebane Enclosures CITY OF MEBANE 106 E.Washineton St t Mebane.NC 27302 0 919 304 9217 919 563 6144 0 avarinos}-i citvofinehane.com www. CITYOFMEBANE. com CITY OF MEBANE WASTEWATER TREATMENT FACILITY NPDES PERMIT NO. NC 0021474 ANNUAL PRETREATMENT PROGRAM REPORT RECEWai,r�,kIr EPIPENR/®WR FEB252019 e�ource� Nrmitting Section PERIOD COVERED BY THIS REPORT: January 1, 2018 - December 31, 2018 PERSON TO CONTACT CONCERNING INFORMATION CONTAINED IN THIS REPORT: NAME: Amy Varinoski TITLE: Compliance Manager MAILING ADDRESS: 106 EAST WASHINGTON STREET MEBANE, NORTH CAROLINA 27302 TELEPHONE NUMBER 919-304-9217 I have personally examined and am familiar with the information submitted in this document and attachments. I believe that the submitted information is true, accurate and complete. I am aware that there are significant penalties for submitting false information. SIGNATURE OF OFFICIAL Dennis J. Hodge, Wastewater Director 2/%1 zP/I D to Signed City of Mebane 2018 Annual Pretreatment Report Table of Contents 1 Cover Sheet 2 Table of Contents 3-4 Section 1 - Narrative 5 Section 2 - PPS 6 Section 3 - SNCR 7 Pretreatment Program Info from DWR 8 Historical SNCR from DWR 9-16 Section 4 - IDSF 17-20 Section 5 - Current Allocation Table 21 Section 6 - Compliance Schedules 22 Section 7 - Public Notice 23 Section 8— Other Information 02/12/2019 City of Mebane Pretreatment Annual Report 2018 Page 2 of 23 1 Annual Report Narrative City of Mebane POTW— NPDES NC0021474 General Program Information The Pretreatment Program Info Database sheet has been reviewed for any necessary corrections. All due dates for Major Program Elements have been reviewed and are correct. As noted on the included Pretreatment Program Info Database sheet, please correct the following phone numbers: • Amy Varinoski from 919-727-1655 to 919-304-9217 • Amanda Hill from 919-304-9220 to 919-563-6141 x804 No other corrections are noted for the Database at this time. A Headworks Analysis was submitted by the City of Mebane on March 24, 2016 and was approved by PERCS on June 3, 2016. During 2018, Long-Term Monitoring Plan sampling continued by the POTW as outlined in the currently approved LTMP. The City of Mebane WWTP NPDES permit is scheduled to expire on May 31, 2019. In accordance with Part II.B.10. of this NPDES permit, a permit renewal application was submitted to NC DEQ on November 30, 2018. An updated Industrial Waste Survey was submitted to PERCS on January 4, 2016 and was approved by PERCS on March 7, 2016. IWS activity continued during 2018. When requested, the Public Works Director provides a listing of all new sewer taps over 3/4" (typical domestic size) that have been installed. These are reviewed for possible new permittees. Dennis Hodge, Wastewater Director, and Amy Varinoski, Compliance Manager, continue to serve as members of the City's Technical Review Committee. Meetings typically occur the second Tuesday of every month and allow for the review of plans for new construction projects and up-fit of existing facilities. Additionally, in May 2018, all existing dental facilities in Mebane were provided with a "City of Mebane 40 CFR Part 441 Fact Sheet" and a "City of Mebane One Time Compliance Report (OTCR) for Dental Dischargers". The OTCR, per 40 CFR 441, is required to be completed and submitted to the POTW on/before October 12, 2020, as applicable. All SIUs were sampled and inspected in 2018. Inspection dates for each SIU are listed below. Enforcement was issued to industries for all noted permit violations. A Pretreatment Program Inspection was performed by Jim Gonsiewski of the Winston- Salem Regional Office on June 26, 2018. No deficiencies were noted and overall the inspection showed the City's pretreatment program to be satisfactory and effective. POTW waste reduction activity is recycling. Newspapers, plastic beverage containers, cardboard, office paper, and aluminum and steel cans are recycled by Waste Industries. Biosolids are dewatered and used in the production of compost by a third party. EMA Resources was the third party contracted for dewatering in 2018. 02/12/2019 City of Mebane Pretreatment Annual Report 2018 Page 3 of 23 Industrial Connections & Solutions, LLC (formerly General Electric) —6801 Industrial Drive — Permit# 0111 —40CFR433 The facility's permit was modified effective May 15, 2018 to reflect the facility's name change from General Electric to Industrial Connections & Solutions, LLC. Annual inspection of the facility was conducted on November 9, 2018. Liggett Group LLC — 100 Maple Lane — Permit# 0132 —40CFR403 The facility's SIU permit renewal, effective January 1, 2019, was transmitted to Liggett on December 18, 2018. Annual inspection of the facility was conducted on November 7, 2018. MetoKote Corporation — 1020 Corporate Park Drive — Permit# 0133 —40CFR433 In anticipation of the facility's permit expiration on June 30, 2019, MetoKote submitted a permit renewal application on December 27, 2018. Annual inspection of the facility was conducted on November 15, 2018. _ Sandvik Machining Solutions US LLC (formerly Sandvik, Inc.) — 1483 Dogwood Court— Permit# 0118 —40CFR433 Sandvik's permit was modified effective February 1, 2018 to remove the facility's self- monitoring requirements for fluoride and selenium and effective July 1, 2018 to reflect the facility's name change to Sandvik Machining Solutions US LLC. Per telephone and email correspondence with Deborah Gore on November 27, 2018, Sandvik had an exceedance of its chromium limit on October 26, 2018. However, the cause of the exceedance was determined to be the result of an upset at the facility, further proven by bench scale testing conducted by Sandvik in conjunction with Mrs. Varinoski. This constituted an affirmative defense. As such, enforcement action was not taken for this exceedance and the exceedance was not used in either Chronic or TRC violation percentage calculations on the facility's IDSF. Annual inspection of the facility was conducted on July 27, 2018. Synergy Health — 1416 Dogwood Way— Permit# 0126—40CFR403 Annual inspection of the facility was conducted on November 7, 2018. 02/12/2019 City of Mebane Pretreatment Annual Report 2018 Page 4 of 23 Chapter 9, PAR Guidance Pretreatment Performance Summary (PPS) 1. Pretreatment Town Name: City of Mebane 2. "Primary"NPDES Number NCOO 21474 or Non Discharge Permit#if applicable=> 3. PAR begin Date,please enter 01/01/yy 3.=> 1/1/2018 4. PAR end Date, please enter 12/31/yy 4.=> 12/31/2018 5. Total number of SIUs, includes CIUs 5.=> 5 6. Number of CIUs 6.=> 3 7. Number of SIUs with no IUP, or with an expired IUP 7.=> 0 8. Number of SIUs not inspected by POTW 8.=> 0 9. Number of SIUs not sampled by POTW 9.=> 0 10. Number of SIUs in SNC due to IUP Limit violations 10.=> 0 11. Number of SIUs in SNC due to Reporting violations 11.=> 0 12. Number of SIUs in SNC due to violation of a compliance schedule,CO,AO or similar 12.=> 0 13. Number of CIUs in SNC 13.=> 0 14. Number of SIUs included in public notice 14.=> 0 15 Total number of SIUs on a compliance schedule, CO,AO or similar 15.=> 0 16. Number of NOVs,NNCs or similar assesed to SIUs 16.=> 2 17. Number of Civil Penalties assessed to SIUs 17.=> 0 18. Number of Criminal Penalties assessed to SIUs 18.=> 0 19. Total Amount of Civil Penalties Collected 19.=> $ 50 20. Number of lUs from which penalties collected 20.=> 1 Foot Notes: AO Administrative Order IUP Industrial User Pretreatment Permit POTW Publicly Owned Treatment Works CuU Categorical Industrial User NNC Notice of Non-Compliance SIU Significant Industrial User CO Consent Order NOV Notice of Violation SNC Significant Non-Compliance IU Industrial User PAR Pretreatment Annual Report revis 02/z2t120PIA7t PPS 2018 City of Mebane Pretreatment Annual Report 2018 Page 5 of 23 N Pretreatment Annual Report (PAR) PAR Covers 2018 Significant Non-Compliance Report (SNCR) Town Name City of Mebane WWTP = Wastewater Treatment Plant, use separate form for each WWTP. WWTP City of Mebane SIU = Significant Industrial User NPDES# NC0021474 SNC = Significant Non-Compliance 0. A SNCR form must be submitted, please write "None" if you had no SIUs in SNC during the calendar year. C SNC ? ( Yes / No ) = IUP Pipe Industry Name Parameter for each 6-month period. m # # or "Reporting" Jan. - June July- Dec. No industries in SNC for reporting or limits No No 3 CD 3 CD 0 N O cp Attach a copy of the Division's "SIUs in SNC Historical Report" for your POTW's SIUs behind this page . Is the database correct ? Notify the Division of any errors ! Database indicates SNC history for previous years. EVERY SNC MUST be explained in the Narrative, How was, is, or will it be resolved? REPEAT SNCs are serious matters that MUST be explained in the Narrative. P-Tdreattnilettt PrAgran lim o lataiF :Se printed on: 12/12/2018 for Program Name Mebane 4 S,fleli 117fOr%II8fi0%I=emu` IWC%at 7Q10 100.00 WWTP Name City of Mebane ow cfs/mgd 0 / 0.00 Program Approval Date 10/21/1983 1 Q 10 Flow cfs/mgd 0.00 / 0.00 Pretreatment Status Full WS-V, NSW Stream Classification Region WSRO Basin Number CPF02 County Alamance Receiving Stream Name MOADAMS CREEK NPDES Number NC0021474 NPDES Effective Date Last PAR Rec PAR Due Date 03/01/2018 mercury 07/01/2014 Current Fiscal 1631 NPDES Expire Date 05/31/2019 required Year PCI Done POTW is Primary WWTP TRUE Last Audit on 07/16/2015 Audit Year Next19/20 yes Design Flow mgd 2.5000 %Design mgd is SIU permitted 8.50 Permitted SIU flow(mgd)[Pt SIU) 2125 WWTP::: 5 Program Sills 5 3IiNVA< . °LTMP a, IWSsX SUO SuEFtPa WWTP Program CIUs 3 " �. ' �, ao, ,�5 „, 1 - "'rzs.pe 'Sv.,71;,°r.-n.,..»,�. sx,�- ,.+ -7;: _.',:fir«777,T...,r ^t^s*x 75 date Inactive � v'-t"�' �DateaNextDue 031021 °: s� 1'2101/ 0 � a°�:;'�,.:3. Date Received by DWR 03/24/2016 06/07/2004 01/04/2016 11/02/2012 11/02/2012 --non.;��;�n�__��,.�..,�,� _ ,� ri f:13:'s,.4 Date;Approved', 06% 3/2018 ,09/0 t/2004i 3%07 2p16 � 01'2, s 04%11"/20'13�'3 3. a.�ssx.........,.:,ti....,..., .., �. -_..�zh-.. ..w.;�,t."'-ivy..�,::..a.w..»az.�.� "��..a;,a,�,�� �„avk:.�t .�_.ra,...., w..����Ls.�,ar',..,��..�,.v....:a r.�.,.� Adopt Date Required q.U� j ;.'; ':Date°Adopted`r ` _"1,. =,�.,a..,.,�;,F: '-r42-,; ?: F , ', -. 09/13%260', ;.;;a"3°µ;,..1,,;�,'� f%s�..,'s r. ,sr .t; ...a...x.., sa:,aa�:�„zs"�.3i L'� .�.s:usi.� �..us„ .,..:iu'an�"»...,z..'z,ca...sd �..a� �r...,,. �.� ..vu.. tip.:a._... ti,?°a 'Info in this.Box from+Pt` Contacts}° a Aa s'°° s's i `° a Date; abate;. ;Date ;PT°Fro ,;Rt a':q Attended Attended k ,°Attended= Formal.Name _ ., x , w zF-' " .Wks". t, -x , „ g` :Pnr e° '. Phoriel, eat,.<i , Fax FIWAF ps°fp INksp.,`:PAR;Wksp' .gym m D ',N1s:•AmY Var'moski, Pnrn 727-1,055; 919-563-6144 314/2013, 'a3/19/'101 avarinoski@cityofinebane:com ;q `q,.,1 4 4111 ompliance Manager a ;°`: Ey", °Ip106 E AWashington°St.. *I27302e, Mr.Dennis Hodge `` -1 4;" 919 563-6144 6/23/200921 'dhddge@cityofineb'ane:coml , ' Waste ater.Director Amanda II01&404;3' Q. : � '(; . 015-F3/1912.�015 I 1°27/201 achill@cityofinebane:con;tliq,st coLi "" .;:tf �" J'PretreatinentRelated.NOVsfro'm4blN z ..`` `�`�°" Q� "'� DWR Central Office Contact Vivien Zhong DWR Regional Contact Jim Gonsiewski 02/12/2019 City of Mebane Pretreatment Annual Report 2018 Page 7 of 23 nost§rkA REPORT Mebane q• 2011 2012 2013 2014 2015 2016 2017 1st half I 2nd half 1st half 12nd half 1st half I 2nd half 1sthalfI2nd half 1st half 2nd half I 1st half I 2nd half 1st half I 2nd half Lifgett Group, LLC PreviousNames IUP# 0132 Pipe# 001 SIU Word Description. IUP_Status:Active Cigarette manufactunng BOD I I I XI IV okote Corporation PreviousNames: O IUP# 0133 Pipe# 001 SIU Word Description I UP_Status:Active Metal Finishing nt cp Zinc I I I I I X I I sll 3 Iy m cc. • Co CD CO co An'X'in a semi-annual period indicates snc for the period for the respective parameter. PRINTED ON:12/12/2018 This information is compiled from many sources,and has not been verified. PAGE 44 Contact the local pretreatment coordinator or state pretreatment staff if errors are noted. Pretreatment Annual Report(PAR) Control Authority, Industry Industrial Data Summary Form(IDSF) Town Name=> City of Mebane Name General Electric WWTP Name=> Mebane WWTP IUP# 0111 Use separate forms for each industry/pipe NPDES#=> NC0021474 Pipe# 001 ch Enter BDL values as<(value) 1st 6 months,dates=> 1/1/2018 to 6/30/2018 ,N 2nd 6 months,dates=> 7/1/2018 to 12/31/2018 rn a) Flow,mgd BOD TSS Ammonia m co 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months Total#of samples=> 119 112 2 N/A 2 N/A 2 N/A * Maximum (mg/I)=> 0.012078 0.010061 * or Maximum (1b/d)=> * or Average(mg/1)_> 0.007466 0.006494 * or Average Loading(lb/d)=> 13.45 N/A 5 23 N/A <0 006 N/A %violations,(chronic SNC is>=66%)=> ,, N/A N/A N/A N/A N/A N/A ao %TRC violations,(SNC is>=33%)_> A N/A N/A N/A N/A N/A N/A o Compliant Compliant %violations,(chronic SNC is>=66%)_> i N/A N/A N/A N/A N/A N/A o %TRC violations,(SNC is>=33%)=> N/A N/A N/A N/A N/A N/A m Ct Aluminum Cadmium Chromium COD -cis 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months c c Total#of samples=> 6 7 6 7 2 N/A Q * Maximum (mg/1)=> No No <0 002 0.003 0.006 0.008 m * or Maximum (lb/d)=> Monitoring Monitoring E * or Average(mg/1)=> Required Required a * or Average Loading(1b/d)=> By Permit By Permit 45.89 N/A a� %violations,(chronic SNC is>=66%)=> >. 0 0 0 0 N/A N/A d %TRC violations,(SNC is>=33%)_> 0 0 0 0 0 N/A N/A a) c %violations,(chronic SNC is>=66%)=> s N/A N/A N/A N/A N/A N/A as %TRC violations,(SNC is>=33%)=> i N/A N/A N/A N/A N/A N/A Copper Cyanide Lead Mercury °, 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 3 Total#of samples=> 6 7 6 7 6 7 6 7 * Maximum (mg/1)=> 0.015 0.031 0.007 <0.005 0.024 <0.010 <0.0002 <0.0002 * or Maximum (lb/d)=> * or Average(mg/I)=> * or Average Loading(lb/d)=> %violations,(chronic SNC is>=66%)=> ,, 0 0 0 0 0 0 N/A N/A rn %TRC violations,(SNC is>=33%)=> 00 0 0 0 0 0 N/A N/A CV %violations,(chronic SNC is>=66%)=> ,k N/A N/A N/A N/A N/A N/A N/A N/A %TRC violations,(SNC is>=33%)_> � N/A N/A N/A N/A N/A N/A N/A N/A o BDL=>Below Detection Limit mg/I=>milligrams per liter * POTW must enter at least one of these IUP=>Industrial User Permit lb/d=>pounds per day four rows, Please indicate how averages were calculated SNC=>Significant Non-Compliance mgd=>million gallons per day Avg period could be month,Qtr,or 6-month&if BDL,1/2BDL,or zero values used. TRC=>Technical Review Criteria WWTP=>wastewater treatment plant Pretreatment Annual Report (PAR) co Industry Name General Electric N Industrial Data Summary Form (IDSF) IUP# 0111 0 Use separate forms for each industry/pipe Pipe# 001 o a) t3) ca Nickel Selenium Silver Zinc a 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months Total#of samples=> 6 7 6 7 6 7 * Maximum (mg/1)_> 0.031 0.029 No No <0.005 <0.005 0.432 0.066 * or Maximum (lb/d)=> Monitoring Monitoring * or Average(mg/1)_> Required Required * or Average Loading(1b/d)=> By Permit By Permit op %violations,(chronic SNC is>=66%)_> >, 0 0 0 0 0 0 0 %TRC violations,(SNC is>=33%)_> A 0 0 0 0 0 0 N %violations,(chronic SNC is>=66%)_> j N/A N/A N/A N/A 0 0 o o. %TRC violations,(SNC is>=33%)_> i N/A N/A N/A ' N/A 0 0 ce o pH Oil& Grease Phoshorus,Total Fluoride 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months < Q Total#of samples=> 119 112 2 N/A 6 7 6 7 * Maximum (mg/1)=> 9.2 8.5 <5.0 N/A 0.59 0.43 a) * or Maximum (lb/d)=> Min-7.0 Min-6.7 iv * or Average(mg/1)=> 2 * or Average Loading(lb/d)=> 1.94 8.69 a_ %violations,(chronic SNC is>=66%)=> . 0 0 N/A N/A N/A N/A N/A N/A 0 %TRC violations,(SNC is>=33%)_> o N/A N/A N/A N/A N/A N/A N/A N/A a) c %violations,(chronic SNC is>=66%)=> . N/A N/A N/A N/A N/A N/A N/A N/A a) %TRC violations,(SNC is>=33%)_> N/A N/A N/A N/A N/A N/A N/A N/A 2 0 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months U Total#of samples=> * Maximum (mg/1)=> * or Maximum (lb/d)=> * or Average(mg/1)=> * or Average Loading(lb/d)_> _ %violations,(chronic SNC is>=66%)_> T 0) %TRC violations,(SNC is>=33%)=> ra o CV %violations,(chronic SNC is>=66%)=> . r %TRC violations,(SNC is>=33%)_> o BDL=>Below Detection Limit mg/1=>milligrams per liter * POTW must enter at least one of these IUP=>Industnal User Permit lb/d=>pounds per day four rows, Please indicate how averages were calculated SNC=>Significant Non-Compliance mgd=>million gallons per day Avg period could be month,Qtr,or 6-month&if BDL,1/2BDL,or zero values used. TRC=>Technical Review Cntena WWTP=>wastewater treatment plant Pretreatment Annual Report(PAR) Control Authority, Industry Industrial Data Summary Form (IDSF) Town Name=> City of Mebane Name Liggett Group LLC WWTP Name=> Mebane WWTP IUP# 0132 Use separate forms for each industry/pipe NPDES#=> NC0021474 Pipe# 001 N Enter BDL values as<(value) 1st 6 months,dates=> 1/1/2018 to 6/30/2018 4- 0 2nd 6 months,dates=> 7/1/2018 to 12/31/2018 Flow,mgd pH,SU BOD TSS coax 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months a_ Total#of samples=> 181 184 6 7 6 8 6 7 * Maximum (mg/1)=> 0.035521 0.035328 9.7 9.7 570 1,200 120 218 * or Maximum (lb/d)=> Min-6.6 Min-6.0 * or Average(mg/1)=> 0.015917 0.016524 * or Average Loading(lb/d)=> %violations,(chronic SNC is>=66%)=> A 0 0 0 0 0 0 co %TRC violations,(SNC is>=33%)_> A 0 0 0 0 0 0 co Compliant Compliant ' %violations,(chronic SNC is>=66%)_> $ N/A N/A 0 0 0 0 o a. %TRC violations,(SNC is>=33%)_> 1 N/A N/A 0 0 0 0 Ce Ammonia Phosphorus Mercury Zinc To 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months c Total#of samples=> 6 7 6 7 6 7 6 7 Q * Maximum (mg/1)=> <0.0002 <0.0002 0.153 0.133 m * or Maximum (lb/d)=> E its * or Average(mg/1)=> * or Average Loading(lb/d)=> 18.33 1.60 3.05 0.28 %violations,(chronic SNC is>=66%)=> . N/A N/A N/A N/A N/A N/A N/A N/A a %TRC violations,(SNC is>=33%)_> ca N/A N/A N/A N/A N/A N/A N/A N/A a) c %violations,(chronic SNC is>=66%)=> i N/A N/A N/A N/A N/A N/A N/A N/A o sa %TRC violations,(SNC is>=33%)=> N/A N/A N/A N/A N/A N/A N/A N/A M Fluoride ° 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months U Total#of samples=> 6 7 * Maximum (mg/1)=> 1.5 1.7 * or Maximum (lb/d)=> * or Average(mg/1)=> * or Average Loading(lb/d)=> %violations,(chronic SNC is>=66%)_> ,, N/A N/A 0 %TRC violations,(SNC is>=33%)_> ca N/A N/A o CV %violations,(chronic SNC is>=66%)_> i N/A N/A %TRC violations,(SNC is>=33%)=> N/A N/A o BDL=>Below Detection Limit mg/1=>milligrams per liter * POTW must enter at least one of these IUP=>Industrial User Permit lb/d=>pounds per day four rows, Please indicate how averages were calculated SNC=>Significant Non-Compliance mgd=>million gallons per day Avg penod could be month,Qtr,or 6-month&if BDL,1/2BDL,or zero values used TRC=>Technical Review Cnteria WWTP=>wastewater treatment plant Pretreatment Annual Report(PAR) Control Authority, Industry Industrial Data Summary Form(IDSF) Town Name=> City of Mebane Name MetoKote Corp WWTP Name=> Mebane WWTP IUP# 0133 Use separate forms for each industry/pipe NPDES#=> NC0021474 Pipe# 001 co Enter BDL values as<(value) 1st 6 months,dates=> 1/1/2018 to 6/30/2018 0 2nd 6 months,dates=> 7/1/2018 to 12/31/2018 N tv Flow,mgd Cadmium Chromium Copper as a. 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months Total#of samples=> 153 130 6 7 6 7 6 7 * Maximum (mg/1)_> 0.007214 0.009645 <0.002 <0.002 0.01 0.007 0.023 0.037 * or Maximum (lb/d)=> * or Average(mg/1)=> 0.003523 0.005438 - * or Average Loading(1b/d)=> %violations,(chronic SNC is>=66%)=> 0 0 0 0 0 0 co %TRC violations,(SNC is>=33%)_> Q 0 0 0 0 0 0 N — Compliant Compliant -C %violations,(chronic SNC is>=66%)_> e 0 0 0 0 0 0 o o. %TRC violations,(SNC is>=33%)_> 0 0 _ 0 0 0 0Et Lead Nickel Zinc Mercury c 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months c Total#of samples=> 6 7 6 7 6 7 6 7 c * Maximum (mg/1)=> <0.005 <0.005 0.450 0.396 0.124 0.085 <0.0002 <0.0002 a) * or Maximum (lb/d)=> its * or Average(mg/1)=> 2 * or Average Loading(1b/d)=> %violations,(chronic SNC is>=66%)=> 0 0 0 0 0 0 N/A N/A d %TRC violations,(SNC is>=33%)=> A 0 0 0 0 0 0 N/A N/A c %violations,(chronic SNC is>=66%)_> 0 . 0 0 0 0 0 N/A N/A ns m %TRC violations,(SNC is>=33%)_> 0 0 0 0 0 0 N/A N/A 2 0 Silver Cyanide Fluoride pH,SU 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months U Total#of samples=> 6 7 6 7 6 7 6 7 * Maximum (mg/1)=> <0.005 <0.005 0.011 <0.005 9.62 10.1 9.7 9.3 * or Maximum 1b/d => ( Min-8.4 Min-8.2 * or Average(mg/1)=> * or Average Loading(lb/d)=> %violations,(chronic SNC is>=66%)=> 0 0 0 0 N/A N/A 0 0 rn %TRC violations,(SNC is>=33%)=> A 0 0 0 0 N/A N/A 0 0 N %violations,(chronic SNC is>=66%)=> .� 0 0 0 0 N/A N/A N/A N/A N %TRC violations,(SNC is>=33%)=> ` 0 0 0 0 N/A N/A N/A N/A o BDL=>Below Detection Limit mg/1=>milligrams per liter * POTW must enter at least one of these IUP=>Industrial User Permit lb/d=>pounds per day four rows, Please indicate how averages were calculated SNC=>Significant Non-Compliance mgd=>million gallons per day Avg penod could be month,Qtr,or 6-month&if BDL,1/2BDL,or zero values used TRC=>Technical Review Cntena WWTP=>wastewater treatment plant Pretreatment Annual Report (PAR) (NI Industry Name MetoKote Corp Industrial Data Summary Form (IDSF) IUP# 0133 Use separate forms for each industry/pipe Pipe# 001 co a) 0) c>s Phosphorus,Total 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months Total#of samples=> 6 7 * Maximum (mg/1)=> * or Maximum (lb/d)=> * or Average(mg/1)=> * or Average Loading(lb/d)=> 0.1438 0.1945 %violations,(chronic SNC is>=66%)_> N/A N/A co %TRC violations,(SNC is>=33%)=> A N/A N/A cv %violations,(chronic SNC is>=66%)_> N/A N/A Q. %TRC violations,(SNC is>=33%)_> N/A N/A 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months Total#of samples=> * Maximum (mg/1)=> * or Maximum (lb/d)=> * or Average(mg/1)=> * or Average Loading(lb/d)=> ` %violations,(chronic SNC is>=66%)_> a_ %TRC violations,(SNC is>=33%)_> o a) %violations,(chronic SNC is>=66%)=> TRC violations,(SNC is>=33%)_> 0 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months Total#of samples=> * Maximum (mg/1)_> * or Maximum (Ib/d)=> * or Average(mg/1)=> * or Average Loading(lb/d)=> %violations,(chronic SNC is>=66%)=> %TRC violations,(SNC is>=33%)=> A o %violations,(chronic SNC is>=66%)_> s N %TRC violations,(SNC is>=33%)_> - N BDL=>Below Detection Limit mg/1=>milligrams per liter * POTW must enter at least one of these IUP=>Industnal User Permit lb/d=>pounds per day four rows, Please indicate how averages were calculated SNC=>Significant Non-Compliance mgd=>million gallons per day Avg penod could be month,Qtr,or 6-month&if BDL,1/2BDL,or zero values used TRC=>Technical Review Cntena WWTP=>wastewater treatment plant Pretreatment Annual Report(PAR) Control Authority, Industry Industrial Data Summary Form(IDSF) Town Name=> City of Mebane Name Sandvik WWTP Name=> Mebane WWTP IUP# 0118 Use separate forms for each industry/pipe NPDES#=> NC0021474 Pipe# 001 co Enter BDL values as<(value) 1st 6 months,dates=> 1/1/2018 to 6/30/2018 Ei 2nd 6 months,dates=> 7/1/2018 to 12/31/2018 Flow,mgd pH Cadmium Chromium c 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 0_ Total#of samples=> 131 134 28 37 6 7 6 7 _ * Maximum (mg/1)=> 0.001034 0.000856 10.7 10.7 <0.002 <0.002 0.263 1.520 * or Maximum (lb/d)=> Min-8.7 Min-7.4 * or Average(mg/1)=> 0.000463 0.000321 * or Average Loading(lb/d)=> %violations,(chronic SNC is>=66%)=> ? 0 0 0 0 0 0 co %TRC violations,(SNC is>=33%)_> CO 0 0 0 0 0 0 N 77, Compliant Compliant %violations,(chronic SNC is>=66%)=> 11 N/A N/A N/A N/A N/A N/A o %TRC violations,(SNC is>=33%)_> N/A N/A N/A N/A N/A N/A ce Copper Lead Nickel Zinc Tu 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months c c Total#of samples=> 6 7 6 7 6 7 6 7 Q * Maximum (mg/1)_> 0.061 0.096 <0.005 0 0.24 0.284 0.121 0.591 aci * or Maximum (lb/d)=> E * or Average(mg/1)=> ai * or Average Loading(lb/d)_> %violations,(chronic SNC is>=66%)=> .� 0 0 0 0 0 0 0 0 d %TRC violations,(SNC is>=33%)_> A 0 0 0 0 0 0 0 0 c %violations,(chronic SNC is>=66%)=> S N/A N/A N/A N/A N/A N/A N/A N/A a %TRC violations,(SNC is>=33%)_> N/A N/A N/A N/A N/A N/A N/A N/A 2 r- 0 Mercury Silver Selenium Cyanide >, 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months U Total#of samples=> 6 7 6 7 2 1 6 7 * Maximum (mg/1)=> <0.0002 <0.0002 <0.005 <0.005 <0.005 0.006 0.239 0.450 * or Maximum (1b/d)=> * or Average(mg/1)=> * or Average Loading(lb/d)=> %violations,(chronic SNC is>=66%)_> N/A N/A 0 0 0 0 0 0 rn %TRC violations,(SNC is>=33%)=> A N/A N/A 0 0 0 0 0 0 N N %violations,(chronic SNC is>=66%)=> N/A N/A N/A N/A N/A N/A 0 0 N %TRC violations,(SNC is>=33%)_> N/A N/A N/A N/A N/A N/A 0 0 0 BDL=>Below Detection Limit mg/I=>milligrams per liter * POTW must enter at least one of these IUP=>Industrial User Permit lb/d=>pounds per day four rows, Please indicate how averages were calculated SNC=>Significant Non-Compliance mgd=>million gallons per day Avg penod could be month,Qtr,or 6-month&if BDL,1/2BDL,or zero values used TRC=>Technical Review Cntena WWTP=>wastewater treatment plant Pretreatment Annual Report (PAR) co Industry Name Sandvik Industrial Data Summary Form (IDSF) IUP# 0118 Use separate forms for each industry/pipe Pipe# 001 a) 0) _ ca Fluoride 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months Total#of samples=> 2 1 * Maximum (mg/I)=> 0.621 0.67 * or Maximum (lb/d)=> * or Average(mg/1)=> * or Average Loading(lb/d)_> %violations,(chronic SNC is>=66%)_> N/A N/A co %TRC violations,(SNC is>=33%)=> N/A N/A 0 ❑. 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months Total#of samples=> * Maximum (mg/1)_> * or Maximum (lb/d)=> * or Average(mg/1)=> * or Average Loading(lb/d)=> a) %violations,(chronic SNC is>=66%)=> E %TRC violations,(SNC is>=33%)_> 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months Total#of samples=> a) * Maximum (mg/I)=> .0 * or Maximum (1b/d)=> * or Average(mg/1)=> * or Average Loading(1b/d)_> %violations,(chronic SNC is>=66%)_> —�' %TRC violations,(SNC is>=33%)_> U BDL=>Below Detection Limit mg/1=>milligrams per liter * POTW must enter at least one of these IUP=>Industrial User Permit lb/d=>pounds per day four rows, Please indicate how averages were calculated SNC=>Significant Non-Compliance mgd=>million gallons per day Avg period could be month,Qtr,or 6-month&if BDL,1/2BDL,or zero values used TRC=>Technical Review Criteria WWTP=>wastewater treatment plant O O N N Pretreatment Annual Report (PAR) Control Authority, Industry Industrial Data Summary Form (IDSF) Town Name=> City of Mebane Name SRI Surgical Express WWTP Name=> Mebane WWTP IUP# 0126 c•, Use separate forms for each industry/pipe NPDES#=>NC0021474 Pipe# 001 N Enter BDL values as<(value) 1st 6 months,dates=> 1/1/2018 to 6/30/2018 o m 2nd 6 months,dates=> 7/1/2018 to 12/31/2018 a) Flow, mgd pH COD Oil& Grease co 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months Total#of samples=> 129 129 1 1 1 1 1 1 * Maximum (mg/1)=> 0.0591 0.066 9.9 10.39 277 223 <5.0 21.9 * or Maximum (lb/d)=> * or Average(mg/1)_> 0.044524 0.044607 * or Average Loading(lb/d)=> co %violations,(chronic SNC is>=66%)=> Compliant Compliant 0 0 N/A N/A N/A N/A N %TRC violations,(SNC is>=33 %)_> 0 0 N/A N/A N/A N/A 0 o. Phosphorus Chromium Copper Lead w 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1 Total#of samples=> 1 1 1 1 1 1 1 1 c * Maximum (mg/I)=> 0.777 1.170 <0.005 <0.005 0.042 0.033 <0.005 <0.005 Q * or Maximum (lb/d)=> aa) * or Average(mg/1)=> E ra * -or Average Loading(lb/d)_> m %violations,(chronic SNC is>=66%)=> N/A N/A N/A N/A N/A N/A N/A N/A 2 %TRC violations,(SNC is>=33 %)=> N/A N/A N/A N/A N/A N/A N/A N/A a a) c Nickel Zinc Mercury Fluoride as a) 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months M Total#of samples=> 1 1 1 1 1 1 1 1 0 * Maximum (mg/1)=> 0.012 0.008 0.048 0.136 <0.0002 <0.0002 0.408 0.576 * or Maximum (lb/d)=> U * or Average(mg/1)=> * or Average Loading(lb/d)=> %violations,(chronic SNC is>=66%)=> N/A N/A N/A N/A N/A N/A N/A N/A %TRC violations,(SNC is>=33 %)=> N/A N/A N/A N/A N/A N/A N/A N/A BDL=>Below Detection Limit mg/I=>milligrams per liter rn * POTW must enter at least one of these IUP=>Industrial User Permit lb/d=>pounds per day o four rows, Please indicate how averages were calculated SNC=>Significant Non-Compliance mgd=>million gallons per day N Avg period could be month,Qtr,or 6-month&if BDL,1/2BDL,or zero values used. TRC=>Technical Review Criteria WWTP=>wastewater treatment plant N cD Workbook Name : Mebane 2016 HWAATDesign01012019, Worksheet Name: AT Printed.2/13/2019, 10:49 AM Page 1 of 4 Allocation Table - !Spreadsheet Instructions Headworks last approved- 06/03/16 1)Applicable Values should be entered in the Heavy Bordered cells Rest of worksheet is protected,password is N Allocation Table updated 12/18/18 2)Formulas are discussed in the Comprehensive Guidance,Chapter 6,Section C. Permits last modified:- 07/01/18 3)HWA and AT worksheets in this workbook are linked Pollutant Names,MAHLs,Basis,and Uncontrollable load N. in this AT worksheet are automatically entered from the HWA spreadsheet. This includes pollutant names in columns AT through BK pi PoTw=>Mebane WWTP m a NPDEs4#> NC0021474 FLOW BOD TSS Industry Type Renewal Modification Date _ _Permit Limits Permit Limits Permit Limits IUP INDUSTRY NAMES Permit Pipe of Effective Effective Permit Conc. Load Conc. Load Count (Ncasc list nlphabslcly) number number Industry Date Date Expires MGD gaUday mg/1 lbs/daL mg/1 lbs/day 1 Industrial Connections&Solutions 0111 0001 433 07/01/17 05/15/18 06/30/22 0.0140 14,000 2 Liggett Group,LLC 0132 0001 403 01/01/19 12/31/23 0.0500 50,000 1000.00 417.00 300.00 125.10 co 3 MetoKote Corporation 0133 0001 433 07/09/14 06/30/19 0.0200 20,000 N 4 Sandvik Machining Solutions US L 0118 0001 433 07/01/17 07/01/18 06/30/22 0.0035 3,500 5 Synergy Health 0126 0001 403 07/01/16 09/01/17 06/30/21 0.0750 75,000 Q 6 IY 7 8 c 9 C Q 10 c Column Totals=> 0.1625 162,500 417 125 a) E ii Basis=> NPDES Design Design N12 MAHL from HWA(lbs/day)=> NPDES Permitted Flow=> 2.5000 5213 5213 a Uncontrollable Loading(lbs/day)=> 1.2208 2545 2545 a) Total Allowable for Industry(MAIL)(lbs/day)_> 1.2792 2667 2667 c Total Permitted to Industry(lbs/day)=> 0.1625 417 125 -o a) MAIL left(lbs/day)=> 1.1167 2250 2542 2 Percent Allow.Ind.(MAIL)still available(%)=> 87.3% 84.4% 95.3% .- Percent MARL still available(%)=> 44.7% 43.2% 48.8% 2: U 5 Percent MAHL(lbs/day)=> 0.1250 261 261 0) 0 N N N 0 HWA.AT Revised:November 2005 Workbook Name : Mebane 2016 HWAATDesign01012019, Worksheet Name: AT Printed.2/13/2019, 10.49 AM Page 2 of 4 Allocation Table Headworks last approved 06/03/16 co Allocation Table updated. 12/18/18 O Permits last modified 07/01/18 00 0 PoTw=>Mebane WWTP co NPDESt#> NC0021474 Ammonia Arsenic Cadmium Chromium Copper Cyanide Industry Permit Limits Permit Limits Permit Limits Permit Limits Permit Limits Permit Limits IUP INDUSTRY NAMES Permit Pipe Conc. Load Conc. Load Conc. Load Conc. Load Conc. Load Conc. Load Count (please list alphabetcly) number J number mg/1 lbs/day mg/I lbs/day mg/1 lbs/day mg/I lbs/day mg/1 lbs/day mg/1 lbs/day 1 Industrial Connections&Solutions 0111 0001 0.0500 0.0058 1.5000 0.1751 2.0000 0.2335 0.5000 0.0584 2 Liggett Group,LLC 0132 0001 eo 3 MetoKote Corporation 0133 0001 0.0700 0.0117 1.7100 0.2852 2.0700 0.3453 0.1000 0.0167 N 4 Sandvik Machining Solutions US 0118 0001 0.0100 0.0003 1.5000 0.0438 0.6000 0.0175 0.6500 0.0190 -t 5 Synergy Health 0126 0001 0 0. 6 a, lY 7 To 8 Illin c 9 0 Q 10 Column Totals=> I 0 I I I 0.0178 1 0.50421 0.5963 , 0.09401 E AS/Nlt/TF fa Basis=> NPDES Stream Std Stream Std Stream Std inhibition Stream Std N MAHL from HWA(lbs/day)=> 762.57 0.9948 0.0663 3.0397 15.2107 0.1765 d Uncontrollable Loading(lbs/day)=> 253.52 0.0305 0.0102 0.0234 0.2973 0.0285 a) Total Allowable for Industry(MAIL)(lbs/day)_> 509.05 0.9643 0.0561 3.0163 14.9134 0.1480 c to Total Permitted to Industry(lbs/day)=> 0.00 0.0000 0 0178 0.5042 0.5963 0.0940 cl MAIL left(lbs/day)_> 509.05 0.9643 0.0383 2.5121 14.3170 0.0540 2 Percent Allow.Ind.(MAIL)still available(%)_> 100.0% 100.0% 68.3% 83.3% 96.0% 36 5% p Percent MAHL still available(%)=> 66.8% 96.9% 57.8% 82 6% 94.1% 30.6% 5 Percent MARL(lbs/day)_> 38.13 0.0497 0.0033 0.1520 0.7605 0.0088 0 0) O _ N N N O HWA.AT Revised:November 2005 Workbook Name : Mebane 2016 HWAATDesign01012019, Worksheet Name: AT Printed.2/13/2019, 10.49 AM Page 3 of 4 Allocation Table Headworks last approved 06/03/16 N Allocation Table updated 12/18/18 p Permits last modified 07/01/18 rn a) Pon W y=>Mebane WTP coo NPDESik> NC0021474 T a Lead Mercury Molybdenum Nickel Selenium Industry Permit Limits Permit Limits Permit Limits Permit Limits Permit Limits IUP INDUSTRY NAMES Permit Pipe Conc. Load Conc. Load Conc. Load Conc Load Conc. Load Count (please hst alphabehcly) number number mg/1 lbs/day mg/1 lbs/day mg/1 lbs/day mg/1 lbs/day mg/1 lbs/day 1 Industrial Connections&Solutions 0111 0001 0.4300 0.0502 1.0000 0.1168 2 Liggett Group,LLC 0132 0001 -- co 3 MetoKote Corporation 0133 0001 0.4300 0.0717 -_I 2.3800 0.3970- p 4 Sandvik Machining Solutions US L 0118 0001 0.0500 0.0015 1.0000 0.0292- N 5 Synergy Health 0126 0001 -- a 6 lr 8 ' To 9 .c'10 Column Totals=> I I 0.12341 I 0 000000 1 0.0000 0.5429 0.0000 E. E N Basis=> Stream Std Stream Std Stream Std Stream Std MAHL from HWA(lbs/day)=> 0.7015 0.0089331 1.6603 0.1094 d Uncontrollable Loading(lbs/day)=> 0.0377 0.001018 0.0815 0.0611 0.0305 N Total Allowable for Industry(MAIL)(lbs/day)=> 0.6638 0.007915 1.5992 0.0789 c Total Permitted to Industry(lbs/day)_> 0.1234 0.000000 0.0000 0.5429 0.0000 o MAIL left(lbs/day)=> 0.5404 0.007915 1.0563 0 0789 M Percent Allow.Ind.(MAIL)still available(%)_> 81.4% 100.0% #VALUE! 66.0% 100 0% p Percent MAHL still available(%)=> 77.0% 88.6% #VALUE! 63 6% 72.1% _ 5 Percent MAHL(lbs/day)_> t 0.0351 0.000447 0.0830 0.0055 0 rn Co N N N 0 HWA AT Revised November 2005 Workbook Name : Mebane 2016 HWAATDesign01012019, Worksheet Name: AT Printed 2/13/2019, 10.49 AM Page 4 of 4 Allocation Table Headworks last approved 06/03/16 N Allocation Table updated 12/18/18 a Permits last modified 07/01/18 c) N a) POTw=>Mebane WWTP m NPDESJI=> NC0021474 a. Silver Zinc Total Nitrogen Total Phos. Aluminum Fluoride Industry Permit Limits Permit Limits Permit Limits Permit Limits Pennit Limits Permit Limits IUP INDUSTRY NAMES Permit Pipe Conc. Load Conc. Load Conc. Load Conc. Load Conc. Load Conc. Load Count (pleasehst alphabcncly) number number mg/1 lbs/day mg/I lbs/day mg/I lbs/day mg/I lbs/day mg/1 lbs/day mg/1 lbs/day 1 Industnal Connections&Solutions, 0111 0001 0 2400 0.0280 1.4800 0 1728 2 Liggett Group,LLC 0132 0001 - 1.4800 -- --- co 3 MetoKote Co .oration 0133 0001 0.2400 0.0400 1 4 Sandvik Machining Solutions US 0118 0001 0.0100 0.0003 0.6000 0.0175 -- N 5 Synergy Health 0126 0001 -- a fY 67 -8 _ _ -_ -_ -_ Co 9 -- Q 10 ... Column Totals=> I 0.0683 0.4372 0.00 I 0.00I 0.0000 0.0000 aa)i E AS/Nit/TF AS/Nit/TF AS/Nit/TF Basis=> inhibition inhibition NPDES NPDES inhibition Stream Std 2 MAHL from HWA(lbs/day)=> 2.7357 38.7379 765.0776 64.25 1111/I/I//1/Illt 24.2457 Uncontrollable Loading(lbs/day)=> 0.0305 1 8734 439.8396 47.04 65 9759 4.9482 a) Total Allowable for Industry(MAIL)(lbs/day)=> 2.7052 36 8645 325.24 17.21 nn/ rrinun 19.2976 c Total Permitted to Industry(lbs/day)_> 0 0683 0.4372 0.00 0 00 0.0000 0.0000 0 MAIL left(lbs/day)=> 2 6368 36.4273 325 24 17.21 1/111/lIltlllilt 19.2976 2 Percent Allow.Ind.(MAIL)still available(%)=> 97 5% 98 8% 100.0% 100.0% 100.0% 100.0% o Percent MAHL still available(%)=> 96.4% 94.0% 42.5% 26 8% 94.9% 79.6% 5 Percent MAHL(lbs/day)=> 0.1368 1.9369 38.25 3.2123 64.5632 1.2123 U 0) 0 N N N O HWA.AT Revised:November 2005 Section 6 — Compliance Schedules No industries were on a compliance schedule in 2018 nor are any industries currently on one. 02/12/2019 City of Mebane Pretreatment Annual Report 2018 Page 21 of 23 Section 7— Public Notice No industries were in SNC during 2018 for reporting or limits violations. 02/12/2019 City of Mebane Pretreatment Annual Report 2018 Page 22 of 23 Section 8 — Other Information Mrs. Varinoski has participated in the following training events since submittal of the last PAR: • NC-PC Voluntary Pretreatment Certification, Grade 3 Instructor—April 16-20, 2018 • NC AWWA-WEA Western Biological Wastewater Operators School, Grade 3&4 Pretreatment Instructor—August 13, 2018 • NC-PC Industry Day"Pretreatment for Industrial Users", Instructor— January 17, 2019 In addition, Amy is an active member of the North Carolina Pretreatment Consortium, serves as a member of the Certification Board for the NC-PC Voluntary Pretreatment Certification Program, and is a member of the NC-PC Annual Pretreatment Conference planning committee. Amanda Hill, the City's laboratory technician, has continued on-the-job training for pretreatment related tasks. Amanda is also an active member of the North Carolina Pretreatment Consortium. 02/12/2019 City of Mebane Pretreatment Annual Report 2018 Page 23 of 23