Loading...
HomeMy WebLinkAbout20190240 Ver 1_PERSON SR 1703_HYD_SMPv2.08_20180620 (Apr 2018)_20190225l ll�;fl�viiY North Carolina Department of Transportation ;7it ]�'lilLYi3it*r ....... Highway Stormwater Program .� j STORMWATER MANAGEMENT PLAN (Version 2.08; Released April 2018) FOR NCDOT PROJECTS WBS Element: 17BP.S.C.PE TIP No.: SR 1703 County(ies): Person Page 1 of 1 General Project Information WBS Element: 17BP.5.C.PE TIP Number: SR 1703 Project Type: Pipe Replacement Date: 11/27/2018 NCDOT Contact: Heather W. Monta ue Contractor / Desi ner: Wetherill En ineerin /Jer Lindse Address: 2612 North Duke Street Address: 1223 Jones Franklin Road Durham, NC 27704 Raleigh, NC 27606 Phone: 919-220-4600 Phone: 919-851-8077 Email: hwmonta ue ncdot. ov Email: 'lindse wetherillen .com Cit ITown: Roxboro Count ies : Person River Basin s: Neuse CAMA Count ? No Wetlands within Project Limits? Yes Pro'ect Description Pro'ect Len th lin. miles or feet : 100' +/- Surrounding Land Use: woods/ cultivation Proposed Pro'ect Existin Site Pro'ect Built-Upon Area ac. 0.1 ac. 0.1 ac. Typical Cross Section Description: 25' paved roadway with +/- 10" grassed shoulders. 25' paved roadway with +/- 10" grassed shoulders. Annual Avg Daily Traffic (veh/hr/day): Desi n/Future: 990 Year: 2016 Existin : 990 Year: 2016 General Project Narrative: This is a maintenance pipe replacement to replace a triple line of 84" CMP with no headwalls (+/- 72' long) with 1@ 22'-9" x 8'-10" Aluminum Box Culvert with headwalls (+/- (Description of Minimization of Water 58.5' long). Roadway drainage will be sheet flow over grasssed shoulders and roadway fill sections. There are no dissipator pads in the buffer area. There will be rip placed on Quality Impacts) the banks for bank stabilization at the culvert inlet and outlet. Waterbody Information Surface Water Body (1): Unnamed Tributary to North Flat River NCDWR Stream Index No.: 27-3-2 NCDWR Surface Water Classification for Water Body Primary Classification: Water Supply III (WS-III) Supplemental Classification: Nutrient Sensitive Waters (NSW) Other Stream Classification: None Impairments: Aquatic T&E Species? Comments: NRTR Stream ID: Buffer Rules in Effect: Neuse Project Includes Bridge Spanning Water Body? No Deck Drains Discharge Over Buffer? N/A Dissipator Pads Provided in Buffer? No Deck Drains Discharge Over Water Body? No (If yes, provide justification in the General Project Narrative) (If yes, describe in the General Project Narrative; if no, justify in the (If yes, provide justification in the General Project Narrative) General Project Narrative)