Loading...
HomeMy WebLinkAbout20190083 Ver 1_SW Impact Analysis, O&M and add info_20190219Staff Review Does this application have all the attachments needed to accept it into the review process? r Yes r No ID#* Version* 1 20190083 Is this project a public transportation project?* r Yes r No Reviewer List:* Alan Johnson:eads\adjohnson1 Select Reviewing Office:* Mooresville Regional Office - (704) 663-1699 Submittal Type:* Application Attachments Does this project require a request for payment to be sent?* r Yes r No Project Submittal Form Please note: fields marked with a red asterisk below are required. You will not be able to submit the form until all mandatory questions are answered. Project Type: r New Project r Pre -Application Submittal r More Information Response r Other Agency Comments r For the Record Only (Courtesy Copy) New Project - Please check the new project type if you are trying to submit a new project that needs an official approval decision. Pre -Application Submittal - Please check the pre -application submittal if you just want feedback on your submittal and do not have the expectation that your submittal will be considered a complete application requiring a formal decision. More Information Response - Please check this type if you are responding to a request for information from staff and you have and ID# and version for this response. Other Agency Comments - Please check this if you are submitting comments on an existing project. Project Contact Information Name: Jennifer Burdette Who is subrritting the information? Email Address: burdette@mcadamsco.com Project Information Existing ID #: Existing Version: 20190083 1 20170001 (no dashes) Project Name: Brookside Residential Subdivision Is this a public transportation project? r Yes r No Is the project located within a NC DCM Area of Environmental Concern (AEC)? r Yes r No r Unknown County (ies) Iredell Please upload all files that need to be submited. Click the upload button or drag and drop files here to attach docurrent 2019-02-13 Stormwater Impact Analysis.pdf 25.32MB 2019-02-19 SCM Supplement Forms.pdf 693.13KB 2019-01-30 SCM O&M Agreement.pdf 112.7KB Brookside SMP CDs.pdf 47.09MB Only pdf or lore files are accepted. Describe the attachments: SMP components (stormwater impact analysis, supplemental forms, O&M agreement, & construction drawings) V By checking the box and signing box below, I certify that: • I have given true, accurate, and complete information on this form; • I agree that submission of this form is a "transaction" subject to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act) • I agree to conduct this transaction by electronic means pursuant to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act'); • I understand that an electronic signature has the same legal effect and can be enforced in the same way as a written signature; AND • I intend to electronically sign and submit the online form." Signature: Submittal Date: STORMWATER CONTROL MEASURE 'A' CONSTRUCTION SPECIFICATIONS GENERAL NOTES 1. PRIOR TO CONSTRUCTION, ANY DISCREPANCIES IN THE PLANS AND NOTES SHALL BE BROUGHT TO THE DESIGN ENGINEER'S ATTENTION IMMEDIATELY. 2. THE FINAL CERTIFICATION FOR THIS FACILITY WILL INCLUDE A CERTIFICATION BY THE ON-SITE GEOTECHNICAL ENGINEER THAT THE PROJECT WAS CONSTRUCTED PER THE APPROVED PLANS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE ON-SITE GEOTECHNICAL ENGINEER FOR OBSERVATION AND TESTING SUCH THAT THE ON-SITE GEOTECHNICAL ENGINEER CAN CERTIFY THE CONSTRUCTION. 3. ALL CONSTRUCTION ACTIVITY RELATED TO THE PROPOSED STORMWATER MANAGEMENT FACILITY SHALL BE PER THE DETAILS AND SPECIFICATIONS SHOWN IN THESE DRAWINGS. SOILS COMPACTION AND OTHER MISCELLANEOUS DETAILS AND SPECIFICATIONS MAY BE MODIFIED PER THE RECOMMENDATIONS OF THE ON-SITE GEOTECHNICAL ENGINEER. HOWEVER, PRIOR TO IMPLEMENTATION, THE DESIGN ENGINEER SHALL BE NOTIFIED OF ANY DEVIATION FROM THESE DESIGN DRAWINGS, INCLUDING SHOP DRAWINGS FOR ANY PROPOSED MODIFICATION. 4. THE CONTRACTOR SHALL REFER TO THE LANDSCAPE PLAN FOR THE PERMANENT PLANTING PLAN/SCHEDULE. PLEASE NOTE THAT NO TREES/SHRUBS OF ANY TYPE MAY BE PLANTED ON THE PROPOSED DAM EMBANKMENT (FILL AREAS). 5. DURING THE INITIAL STAGES OF CONSTRUCTION THE STORMWATER MANAGEMENT FACILITY MAY BE USED AS A SEDIMENT BASIN FOR EROSION CONTROL PURPOSES. IF SO, THE CONTRACTOR SHALL FOLLOW THE GENERAL CONSTRUCTION SEQUENCE BELOW: 5.1. THE CONTRACTOR SHALL CONSTRUCT THE ENTIRE FACILITY (PERMANENT OUTLET STRUCTURE, DAM, ETC.) WITH THE EXCEPTION OF THE INTERIOR FINE GRADING FOR THE FACILITY. THE INTERIOR FINE GRADING WILL BE CONSTRUCTED ONCE THE EROSION CONTROL PHASE IS COMPLETE. 5.2. THE TEMPORARY DRAW DOWN RISER (OR SKIMMER) SHALL BE CONNECTED TO THE PERMANENT 8"0 DIP DRAIN PIPE. 5.3. ONCE THE UPSTREAM DRAINAGE AREA IS STABILIZED AND THE EROSION CONTROL INSPECTOR APPROVES THE REMOVAL OF THE SEDIMENT BASIN, THE CONTRACTOR SHALL REMOVE THE TEMPORARY DRAW DOWN RISER (OR SKIMMER) AND CLEAN-OUT THE BASIN. ALL SEDIMENT, TRASH, ETC. SHALL BE DISPOSED OF PROPERLY (I.E. - PLACED IN A LANDFILL) AND NOT STOCKPILED IN AN AREA WHERE WATER QUALITY COULD BE ADVERSELY AFFECTED. 5.4. ONCE THE BASIN IS CLEANED OUT, AND ALL EROSION CONTROL DEVICES REMOVED, THE CONTRACTOR SHALL CONSTRUCT THE INTERIOR GRADING SHOWN ON THIS SHEET. 5.5. ONCE THE GRADING IS COMPLETE, THE CONTRACTOR SHALL REQUEST AN ON-SITE INSPECTION AND AN AS -BUILT SURVEY PRIOR TO INSTALLATION OF THE STORMWATER MANAGEMENT FACILITY PLANTS. IF THE CONTRACTOR PLANTS THE PROPOSED VEGETATION PRIOR TO AN AS -BUILT SURVEY (AND SUBSEQUENT APPROVAL), ANY CHANGES TO THE GRADING / RE -PLANTING OF PLANTS WILL BE AT THE CONTRACTOR'S EXPENSE. 5.6. ONCE THE ENGINEER HAS APPROVED THE AS -BUILT GRADING, THE CONTRACTOR SHALL PLANT THE PROPOSED STORMWATER MANAGEMENT FACILITY PLANTS SHOWN ON THE LANDSCAPE PLAN FOR THE FACILITY. AFTER COMPLETION OF THE PLANTING, THE LANDSCAPE CONTRACTOR SHALL PROVIDE A LETTER TO THE ENGINEER CERTIFYING THAT THE PLANTS HAVE BEEN INSTALLED PER THE APPROVED STORMWATER MANAGEMENT FACILITY PLANTING PLAN. 6. THE GRADES SHOWN ON THIS PLAN ARE FINISHED GRADES. IF THE EXISTING SOIL LAYER ALONG THE FOREBAY BERM IN THE PROPOSED WET POND AFTER CONSTRUCTION / COMPACTION IS NOT DETERMINED SUITABLE BY A LANDSCAPE PROFESSIONAL FOR THE WETLAND PLANTINGS, THEN THE CONTRACTOR SHALL AMEND THE PLANTING AREA OF THE WET POND AS DIRECTED BY A LANDSCAPE PROFESSIONAL. 7. ANY REMOVED TOPSOIL SHALL BE STOCKPILED FOR USE IN PLANTING (SEEDING) ON THE DAM EMBANKMENT ONCE FINAL GRADES (AS SHOWN ON THE GRADING PLAN) HAVE BEEN ESTABLISHED WITH COMPACTED FILL. PRIOR TO TOPSOIL INSTALLATION, THE CONTRACTOR SHALL SCARIFY THE THE TOP 2"-3" OF THE BERM SECTION TO PROMOTE BONDING OF THE TOPSOIL WITH THE COMPACTED FILL. THE TOPSOIL DEPTH SHALL RANGE FROM 3"-4" ON THE DAM EMBANKMENT. PLEASE NOTE THE STOCKPILED TOPSOIL SHALL BE AMENDED, AS DIRECTED BY A LANDSCAPE PROFESSIONAL, PRIOR TO INSTALLATION ON THE EMBANKMENT. 8. IT IS ANTICIPATED THAT DEWATERING WILL BE NECESSARY IN THE EXCAVATION AREAS (E.G. - EMBANKMENT SUB GRADE, INTERIOR PORTIONS OF THE STORMWATER FACILITY, KEY TRENCH, ETC.). THEREFORE, THE CONTRACTOR SHALL FURNISH, INSTALL, OPERATE, AND MAINTAIN ANY PUMPING EQUIPMENT, ETC.. NEEDED FOR REMOVAL OF WATER FROM VARIOUS PARTS OF THE STORMWATER FACILITY SITE. DURING PLACEMENT OF FILL WITHIN THESE AREAS THE CONTRACTOR SHALL KEEP THE WATER LEVEL BELOW THE BOTTOM OF THE EXCAVATION / CONSTRUCTION AREAS. THE MANNER IN WHICH THE WATER IS REMOVED SHALL BE SUCH THAT THE EXCAVATION BOTTOM AND SIDE SLOPES ARE STABLE WITH NO SEDIMENT DISCHARGED FROM THE SITE (I.E. PUMPED WATER MAY NEED TO BE DIRECTED TO AN APPROVED EROSION CONTROL DEVICE SUCH AS A DIRT BAG (ACF ENVIRONMENTAL), OR ENGINEER APPROVED EQUIVALENT, PRIOR TO DISCHARGE). 9. THE RETAINING WALL ALIGNMENT SHOWN ON THESE PLANS DEPICTS THE LOCATION OF THE FRONT FACE OF THE RETAINING WALL AT THE BOTTOM. 10. THE RETAINING WALL IS TO BE A DESIGN -BUILD PROJECT(S) BY THE CONTRACTOR. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN FINAL CONSTRUCTION DRAWINGS FROM A REGISTERED PROFESSIONAL ENGINEER AND GAIN ALL REQUIRED PERMITS NECESSARY FOR THE CONSTRUCTION OF THE RETAINING WALL. 11. THE RETAINING WALL SHALL BE ASSUMED TO BE BACKFILLED WITH OFF-SITE BORROW MATERIAL OR PROCESSED FILL UNLESS CONTRACTOR CAN PROVIDE OWNER WITH CONFIRMATION FROM THE GEOTECHNICAL ENGINEER AND THE RETAINING WALL DESIGNER THAT READILY AVAILABLE ON-SITE SOILS CAN BE USED. 12. THE TOP AND BOTTOM OF WALL ELEVATIONS SHOWN ON THESE PLANS IDENTIFY FINISHED GRADE ELEVATIONS ONLY. THE EXTENT THAT THE RETAINING WALL WILL BE EXTENDED BELOW GRADE TO THE FOOTING SHALL BE IDENTIFIED ON THE RETAINING WALL CONSTRUCTION DRAWINGS. BERM AND SOIL COMPACTION SPECIFICATIONS 1. PRIOR TO CONSTRUCTION, THE ON-SITE GEOTECHNICAL ENGINEER SHALL IDENTIFY BORROW / FILL AREAS AND VERIFY THEIR SUITABILITY FOR USE WITHIN THE DAM EMBANKMENT. ALSO, THE ON-SITE GEOTECHNICAL ENGINEER SHALL PERFORM STANDARD PROCTORS ON THE PROPOSED BORROW MATERIAL TO ENSURE THAT OPTIMUM MOISTURE CONTENT AND COMPACTION CAN BE ACHIEVED/ CONTROLLED DURING CONSTRUCTION. 2. ALL FILL MATERIALS TO BE USED FOR THE DAM EMBANKMENT SHALL BE TAKEN FROM BORROW AREAS APPROVED BY THE ON-SITE GEOTECHNICAL ENGINEER. THE FILL MATERIAL SHALL BE FREE FROM ROOTS, STUMPS, WOOD, STONES GREATER THAN 6", AND FROZEN OR OTHER OBJECTIONABLE MATERIAL. THE FOLLOWING SOIL TYPES ARE SUITABLE FOR USE AS FILL WITHIN THE DAM EMBANKMENT AND KEY TRENCH: ML AND CL. 3. FILL PLACEMENT FOR THE EMBANKMENT SHALL NOT EXCEED A MAXIMUM 8" LIFT (UNCOMPACTED). EACH LIFT SHALL BE CONTINUOUS FOR THE ENTIRE LENGTH OF EMBANKMENT. BEFORE PLACEMENT OF FILL FOR THE BERM SECTION, ALL UNSUITABLE MATERIAL SHALL BE REMOVED AND THE SURFACE PROPERLY PREPARED FOR FILL PLACEMENT. FILL MATERIAL ADJACENT TO ALL SPILLWAY AND DRAINAGE STRUCTURES SHALL BE PLACED IN 4 -INCH (UNCOMPACTED) LIFTS AND HAND -COMPACTED TO THE SAME COMPACTION AND MOISTURE REQUIREMENTS AS THE ENTIRE EMBANKMENT. 4. ALL FILL SOILS USED IN THE EMBANKMENT CONSTRUCTION SHALL BE COMPACTED TO AT LEAST 95% OF THE STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM -698). THE FILL SOILS SHALL BE COMPACTED AT A MOISTURE CONTENT WITHIN -1 TO +3 PERCENT OF ITS OPTIMUM MOISTURE CONTENT. COMPACTION TESTS SHALL BE PERFORMED BY THE ON-SITE GEOTECHNICAL ENGINEER DURING CONSTRUCTION TO VERIFY THAT THE PROPER COMPACTION LEVEL HAS BEEN REACHED. THE FILL SHOULD BE COMPACTED USING A SHEEPSFOOT TYPE COMPACTOR. IN ORDER TO PREVENT DAMAGE TO THE PIPE, NO COMPACTION EQUIPMENT SHALL CROSS ANY PIPE UNTIL MINIMUM COVER IS ESTABLISHED ALONG THE PIPE. 5. THE DESIGN ENGINEER SHALL BE PROVIDED WITH REPORTS AND CERTIFICATION, BY THE ON-SITE GEOTECHNICAL ENGINEER, THAT THE GEOTECHNICAL ASPECTS OF THE FACILITY HAVE BEEN CONSTRUCTED PER PLAN. THESE REPORTS AND CERTIFICATION WILL BE NEEDED DURING THE AS -BUILT CERTIFICATION PROCESS FOR THIS STORMWATER FACILITY. THEREFORE, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE TESTING AND OBSERVATION WITH THE ON-SITE GEOTECHNICAL ENGINEER. 6. TESTING OF THE NEW FILL MATERIALS SHALL BE PERFORMED TO VERIFY THAT THE RECOMMENDED LEVEL OF COMPACTION IS ACHIEVED DURING CONSTRUCTION. THEREFORE, ONE DENSITY TEST SHALL BE PERFORMED FOR EVERY 2,500 SQUARE FEET OF AREA FOR EVERY LIFT OF FILL OR AS RECOMMENDED BY THE ON-SITE GEOTECHNICAL ENGINEER. 7. TESTING WILL BE REQUIRED ALONG THE 24"0 RCP OUTLET BARREL AT A FREQUENCY OF ONE TEST PER 25 LF OF PIPE PER VERTICAL FOOT OF FILL OR AS DIRECTED BY THE ON-SITE GEOTECHNICAL ENGINEER. STATEMENT OF RESPONSIBILITY 1. ALL REQUIRED MAINTENANCE AND INSPECTIONS OF THE STORMWATER MANAGEMENT FACILITIES SHALL BE THE RESPONSIBILITY OF THE OWNER, PER THE EXECUTED OPERATION AND MAINTENANCE AGREEMENT FOR THIS FACILITY. CONSTRUCTION SEQUENCE 1. PRIOR TO CONSTRUCTION, THE OWNER SHALL OBTAIN A LAND DISTURBING (GRADING) PERMIT AND AN "APPROVAL TO CONSTRUCT" FROM THE TOWN OF TROUTMAN AND ALL OTHER NECESSARY PERMITS FROM APPLICABLE AGENCIES (E.G. 404 / 401 PERMITS) 2. INSTALL ALL SEDIMENT AND EROSION CONTROL MEASURES PER THE APPROVED SEDIMENT AND EROSION CONTROL PLAN. THE CONTRACTOR SHALL MAINTAIN ALL APPROVED SEDIMENT AND EROSION CONTROL MEASURES THROUGHOUT THE ENTIRE PROJECT, AS REQUIRED. THE CONTRACTOR SHALL RECEIVE APPROVAL FROM THE EROSION CONTROL INSPECTOR, AS REQUIRED BY GOVERNING AGENCIES, PRIOR TO ANY CLEARING. 3. CLEAR AND GRUB AREA WITHIN THE LIMITS OF THE PROPOSED DAM CONSTRUCTION. ALL TREES AND THEIR ENTIRE ROOT SYSTEMS MUST BE REMOVED FROM THE DAM FOOTPRINT AREA AND BACKFILLED WITH SUITABLE SOIL MATERIAL. THE BACKFILLED AREAS SHALL BE COMPACTED TO THE SAME STANDARDS AS THE DAM EMBANKMENT. THE REMAINING AREA OF THE EMBANKMENT SHALL BE STRIPPED TO A SUITABLE DEPTH AS DIRECTED BY THE ON-SITE GEOTECHNICAL ENGINEER. ANY RESIDUAL SOILS TO BE LEFT IN PLACE MUST BE WELL SCARIFIED TO PROMOTE BONDING OF THE NEW EMBANKMENT FILL. NO EMBANKMENT MATERIAL SHALL BE PLACED FOR THE DAM OR KEY TRENCH UNTIL APPROVAL OF THE DAM SUBGRADE / TRENCH IS OBTAINED FROM THE ON-SITE GEOTECHNICAL ENGINEER. 4. EXCAVATE FOR THE NEW KEY TRENCH ALONG THE CENTERLINE OF THE PROPOSED DAM EMBANKMENT. THE TRENCH SHALL EXTEND A MINIMUM OF 5 FT BELOW EXISTING GRADE OR 2 FT BELOW THE CONCRETE CRADLE AND SHALL HAVE A MINIMUM BOTTOM WIDTH OF 5 FEET. THE KEY TRENCH SIDESLOPES SHALL BE A MINIMUM OF 1:1 (H:V). THE KEY TRENCH SHALL BE COMPACTED TO THE SAME SPECIFICATION LISTED IN ITEM 4 OF THE SECTION TITLED "BERM AND SOIL COMPACTION SPECIFICATIONS." DEPENDING UPON ON-SITE SOIL CONDITIONS ENCOUNTERED DURING EXCAVATION, THE ON-SITE GEOTECHNICAL ENGINEER MAY VARY THE DEPTH AND DIMENSIONS OF THE KEY TRENCH AS DEEMED NECESSARY. THE ON-SITE GEOTECHNICAL ENGINEER SHALL RETAIN DOCUMENTATION OF ANY VARIATION FOR FUTURE AS -BUILT SUBMITTALS TO THE TOWN OF TROUTMAN. 5. BEGIN PLACEMENT OF BACKFILL WITHIN THE KEY TRENCH. THE KEY TRENCH SHALL BE COMPACTED TO THE SPECIFICATIONS LISTED ITEM 4 OF THE SECTION TITLED "BERM AND SOIL COMPACTION SPECIFICATIONS." THE KEY TRENCH SHALL BE TESTED PER THE SPECIFICATIONS LISTED IN THAT SECTION. 6. PRIOR TO INSTALLATION, SUBGRADE CONDITIONS ALONG THE SPILLWAY PIPES SHOULD BE EVALUATED BY THE ON-SITE GEOTECHNICAL ENGINEER TO ASSESS WHETHER SUITABLE BEARING CONDITIONS EXIST AT THE SUBGRADE LEVEL. SHOULD SOFT OR OTHERWISE UNSUITABLE CONDITIONS BE ENCOUNTERED ALONG THE PIPE ALIGNMENTS, THESE MATERIALS SHOULD BE UNDERCUT AS DIRECTED BY THE GEOTECHNICAL ENGINEER. THE UNDERCUT MATERIALS SHALL BE REPLACED WITH ADEQUATELY COMPACTED STRUCTURAL FILL, LEAN CONCRETE OR FLOWABLE FILL AS DIRECTED BY THE ON-SITE GEOTECHNICAL ENGINEER. 7. IN ORDER TO HELP PROTECTTHE SOIL SUBGRADE FROM DETERIORATION (DUE TO EXPOSURE, RAINFALL, SEEPAGE, AND RUNOFF) BEFORE THE CRADLE CAN BE POURED, IT IS STRONGLY RECOMMENDED THAT A 3" TO 4" THICK CONCRETE MUD MAT BE POURED OVER THE SUBGRADE ONCE IT IS APPROVED BY THE ON-SITE GEOTECHNICAL ENGINEER. THE MUD MAT WILL ALSO PROVIDE BEARING FOR THE BLOCKS THAT TEMPORARILY SUPPORT THE SPILLWAY PIPE UNTIL THE CRADLE CAN BE POURED. THE METHOD OF BLOCK SUPPORT FOR THE PIPE PROPOSED BY THE CONTRACTOR SHOULD BE SUBMITTED TO THE JOHN R. MCADAMS COMPANY FOR REVIEW. 8. BEGIN CONSTRUCTION OF THE NEW EMBANKMENT. FILL MATERIALS SHALL BE PLACED IN MAXIMUM 8 THICK LIFTS PRIOR TO COMPACTION, UNLESS DIRECTED OTHERWISE BY THE ON-SITE GEOTECHNICAL ENGINEER. FILL LIFTS SHALL BE CONTINUOUS OVER THE ENTIRE LENGTH OF FILL. IF IT IS NECESSARY, THE EMBANKMENT FILL MATERIAL WILL BE OVERBUILT IN HORIZONTAL LIFTS AND CUT BACK TO FINAL GRADE IN ORDER TO ACHIEVE PROPER COMPACTION. 9. AS CONSTRUCTION OF THE EMBANKMENT MOVES FORWARD, IT WILL BE NECESSARY TO INSTALL THE CONCRETE CRADLE. THIS MAY BE CONSTRUCTED USING ONE OF THE FOLLOWING METHODS: 9.1. IF THE PROPOSED STRUCTURAL FILL MATERIAL IS UTILIZED AS THE FORMWORK FOR THE CONCRETE CRADLE THEN THE STRUCTURAL FILL SHOULD BE INSTALLED AND COMPACTED UP TO THE TOP OF CONCRETE CRADLE ELEVATION. ONCE THE STRUCTURAL FILL REACHES THE NEXT DOWNSTREAM JUNCTION BOX OR HEADWALL AND IS COMPACTED TO THE ELEVATION OF THE TOP OF THE CONCRETE CRADLE, EXCAVATE THE CONCRETE CRADLE TRENCH PER THE PROVIDED DETAILS AND CONSTRUCT THE CONCRETE CRADLE AS PER THE PROVIDED CONCRETE CRADLE DETAIL. 9.2. IF THE PROPOSED STRUCTURAL FILL IS NOT UTILIZED AS THE FORMWORK FOR THE CONCRETE CRADLE, THEN PRIOR TO CONSTRUCTING THE STRUCTURAL FILL EMBANKMENT, THE FORMWORK FOR THE CONCRETE CRADLE SHOULD BE INSTALLED ON EXISTING GROUND AND / OR THE MUD MAT. THE CONCRETE CRADLE SHALL BE CONSTRUCTED PER THE PROVIDED DETAILS. 10. INSTALL RISER / BARREL ASSEMBLY, ALONG WITH THE EMERGENCY DRAIN SYSTEM. THE DRAIN VALVE LOCATED WITHIN THE RISER BOX SHALL BE KEPT OPEN UNTIL AN AS -BUILT CERTIFICATION HAS BEEN COMPLETED BY THE ENGINEER AND AN APPROVAL TO IMPOUND HAS BEEN ISSUED BY ALL APPLICABLE AGENCIES. 11. INSTALL 24" RCP OUTLET BARREL SPILLWAY FILTER FROM THE DETAILS SHOWN ON SHEET SHEET SW -A4. 12. CONSTRUCT EMBANKMENT PER SPECIFICATIONS LISTED IN THE SECTION TITLED "BERM AND SOIL COMPACTION SPECIFICATIONS" AND REQUIREMENTS OF THE ON-SITE GEOTECHNICAL ENGINEER. ALL CHARACTERISTICS OF THE EMBANKMENT FILL MATERIAL SHALL MEET THE STANDARDS SET FORTH IN "BERM AND SOIL COMPACTION SPECIFICATIONS", INCLUDING COMPACTION AND MOISTURE REQUIREMENTS. IF NECESSARY TO ACHIEVE PROPER COMPACTION, THE EMBANKMENT FILL MATERIAL WILL BE OVERBUILT IN HORIZONTAL LIFTS AND CUT BACK TO PROPER FINAL GRADE. ANY HAND COMPACTION ACTIVITIES AROUND SPILLWAY OR DRAIN STRUCTURES SHALL BE CONDUCTED IN 4 -INCH LOOSE LIFTS AND BE TO THE SAME COMPACTION AND MOISTURE REQUIREMENTS AS THE ENTIRE EMBANKMENT. ALL COMPACTION AND MOISTURE TESTING SHALL BE CARRIED OUT AS DIRECTED BY THE ON-SITE GEOTECHNICAL ENGINEER AND AS LISTED IN THE SECTION TITLED "BERM AND SOIL COMPACTION SPECIFICATIONS". 13. UPON COMPLETION OF DAM EMBANKMENT, PROMPTLY STABILIZE AND SEED DAM EMBANKMENT PER SEEDING SCHEDULE. 14. SCHEDULE A FINAL AS -BUILT INSPECTION AND AS -BUILT SURVEY WITH THE ENGINEER. AN AS -BUILT INSPECTION SHOULD BE SCHEDULED A MINIMUM OF 60 DAYS BEFORE A PERMIT TO IMPOUND IS REQUIRED. ANY COMMENTS OR DEFICIENCIES IN THE DAM CONSTRUCTION MUST BE CORRECTED TO THE SATISFACTION OF THE ENGINEER AND OWNER BEFORE CERTIFICATION SHALL BE GRANTED. UPON FINAL APPROVAL FROM THE TOWN OF TROUTMAN, CLOSE THE 8"0 BOTTOM DRAIN VALVE IN THE RISER BOX AND BEGIN IMPOUNDING WATER. NO WATER SHALL BE IMPOUNDED BEFORE AN APPROVAL TO IMPOUND IS ISSUED FROM THE TOWN OF TROUTMAN. OUTLET STRUCTURE MATERIAL SPECIFICATIONS \ / 63 / J =867.00 / BW= \ \ \ 56 �0 =8590 �59,50 /w// / 0 �W TW=860.00 / 84 8 r7 0 BW=858.00 i / I / / SEDIMENT 7 \/ / J V A0 \ � v / � / 1 v INV = 852.00 \ / / FOREBAY \ \/§ , / �/ / // I A I I I\ 111 V A \ \\ \ \ RETAINING WALL (TYP.) (DESIGN \ BY OTHERS) FOREBAY , , WEIR SPILLWAY \ CREST = 9 LF V \ TOP OF RIP RAP (CREST) = 851.50 LINER = NCDOT CLASS "B" RIPRAP \ \ \ / 8 � 15" MIN. DEPTH (D50 = 8) I \ \ I I ( / / 848 NOTE: A FILTER BLANKET IS TO BE IIII , INSTALLED BETWEEN THE RIP RAP AND SOIL / FOUNDATION. THE FILTER BLANKET WILL /CONSIST OF A MINIMUM 4" THICK LAYER OF STONE (#57) UNDERLAIN WITH MIRAFI FILTER //STONE 700 OR APPROVED EQUIVALENT / FOREBAY BERM EL. = 852.00 /MINIMUM IBE S FT COMPACTED O i PER "BERM AND SOIL / COMPACTION SPECIFICATIONS" / /CIDco00 CID /TOP OF BANK (TYP.) 100 STREAM BUFFER TYP.) BR .,( TW 6 .00 BW 8 8.0 I / I I I l I h l o/ / l \ I I I I / I I' / STORMWATER CONTROL MEASURE /0 o \ I I I / / MAINTENANCE ACCESS EASEMENT 41 '�I I II I I I ROM EL. /8 51.50 /TO/�852.50 SC�/ o //6 -FT AQUATIC SHELF F S�3 ®6:1 SLOPE (TO BE INSTALLED 0PF / / I / I I I / / / AROUND SWMF PERIMETER)/ / / I I III I I I�I II II \ \ I / I I \ \ / MAIN\ POOL / \ \ PRECAST RISER OUTLET STRUCTURE SHAPE = SQUARE INTERNAL DIMENSIONS = 4 FT. x 4 FT. TOP OF RISER = 856.00 1.0"0 ORIFICE = 853.00 2.25"0 ORIFICE (INVERTED SIPHON) = 852.00 INVERT OUT (24"0 0 -RING RCP) = 846.00 I (SEE DETAIL ON SHEET SW -A2) V \ I I I// 97 LF 24"0 CLASS III O-RING CONCRET ® W� CRADLE '00 I o 1 1 1 (JOINTS WRAPPED WRAPIPED IN 3:1I 3:1 GEOTEXTILE FABRIC)SLOPE SLOPE ENDWAILL PER N/ C/D/OT /S/TD. 8/3 880 / �o M / O I w I I Ivco N wcn CID I v >II A I INV. OUT (24-0 RCP) = 845.00 46 � cn n (SEE DETAIL ON SHEET SW -A3) ao n> 411, 0) oono m � i / C: 00 00 coo r o I I I I I I I \\ I I ro 1Lo 00 I I I I '0 II I� II► � v VELOCITY DISSIPATOR NCDOT CLASS 'B'RIPRAP 84 I / 1121 X 6'W X 22 THICK D50 = 8 ( SEE DETAIL SHEET SW -A4) II I I I I \ \ \ \ \ \ 10, / I O / � ASPHALT \ \ / GREENWAY 1 \ i - 851150 852 CONTRACTOR SHALL LINE OUT CHANNEL WITH NCDOT CLASS 'B' RIPRAP. THERE SHALL BE NO DISTURBANCE TO \ a 848 M� ` / I \ \ FOREBAY WEIR SPILLWAY \ \ ANY EXISTING CHANNEL BANk. A FILTER ` I I CREST = 9 LF \ \ \ \ BLANKET SHOULD BE INSTALLED BETWEEN \ \ TOP OF RIP RAP (CREST) = 851.50 RIPRAP & SOIL FOUNDATION. FILTER H „ BLANKET SHALL CONSIST OF A MINIMUM I � LINER = NCDOT CLASS B RIPRAP / / SEDIMENT I H 4" THICK LAYER OF NCDOT 57 STONE FOREBAY I 15 MIN. DEPTH (D50 = 8) ( UNDERDRAIN WITH MIRAFI FILTER WEAVE \I I I I h \ # I IA /I NOTE: A FILTER BLANKET IS TO BE \ 700 OR APPROVED EQUIVALENT. / INSTALLED BETWEEN THE RIP RAP AND SOIL- / I 1I FOUNDATION. THE FILTER BLANKET WILL CONSIST OF A MINIMUM 4" THICK LAYER OF STONE (#57) UNDERLAIN WITH MIRAFI FILTER \ WEAVE 700 OR APPROVED EQUIVALENT \ / \ FOREBAY BERM EL. = 852.00 8�I MINIMUM WIDTH = 5 FTTO E BERM COMPACTED �AND PERSOIL II / COMPACTION SPECIFICATIONS" �I IINV = 852.00 \ \ \ \1 GRAPHIC SCALE 0 10 20 40 STORMWATER CONTROL MEASURE 'A' PLAN VIEW 1" = 20' 1 inch = 20 ft. FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER (vI�I V � z�00 W UDC) LU 1. THE 24"0 RCP OUTLET BARREL SHALL BE CLASS III RCP, MODIFIED BELL AND SPIGOT, MEETING THE REQUIREMENTS OF Z)ca W ASTM C76 -LATEST. THE PIPES SHALL HAVE CONFINED O-RING RUBBER GASKET JOINTS MEETING ASTM C -443 -LATEST. THE \ \ QN PIPE JOINTS SHALL BE TYPE R-4. / \ 2. THE STRUCTURAL DESIGN FOR THE 4'X 4' INTERNAL DIMENSIONS RISER BOX WITH EXTENDED BASE SHALL BE BY J OTHERS. PRIOR TO ORDERING THE STRUCTURES THE CONTRACTOR SHALL PROVIDE TO THE DESIGN ENGINEER FOR \ v,or- REVIEW, SHOP DRAWINGS AND SUPPORTING STRUCTURAL CALCULATIONS SEALED BY A P.E. REGISTERED IN NORTH \ z``'U CAROLINA DEMONSTRATING THE PERTINENT VERTICAL LOADS ARE SUPPORTED BY THE CONCRETE RISER STRUCTURE. \ O \ 3. THE RISER BOX OUTLET STRUCTURE SHALL BE PROVIDED WITH STEPS 16" ON CENTER. STEPS SHALL BE PROVIDED ON THE INNER WALL OF THE RISER BOX. STEPS SHALL BE IN ACCORDANCE WITH NCDOT STD. 840.66. PLEASE REFER TO SHEET = SW -A2 FOR LOCATION OF THE RISER STEPS. 4. THE CONCRETE ANTI -FLOTATION BLOCKS SHALL BE PRECAST AS THE EXTENDED BASE OF THE RISER BOX DURING FABRICATION. THE PRECAST BASE SHALL BE INCLUDED AS PART OF THE SHOP DRAWINGS THAT WILL BE SUBMITTED TO \ THE ENGINEER FOR REVIEW SEE ITEM 2 ABOVE). IN LIEU OF A PRE -CAST BASE THE CONTRACTOR MAY OPT TO CAST -IN-PLACE THE ANTI -FLOTATION BLOCK IN THE FIELD. HOWEVER, PRIOR TO CONSTRUCTING THE CAST -IN-PLACE BASE, THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE ENGINEER FOR REVIEW DENOTING THE FOLLOWING: A. STEEL REINFORCEMENT B. THE CONNECTION MECHANISM TO JOIN THE ANTI -FLOTATION BLOCK WITH THE RISER SECTION 5. IF THE ANTI -FLOTATION BLOCK IS PRECAST AS PART OF THE RISER BASE SECTION, THE ENTIRE PRECAST RISER BOX STRUCTURE SHALL HAVE A SHIPPING WEIGHT OF 31,340 LBS. THE STRUCTURE WEIGHT SHALL BE THE SHIPPING WEIGHT AND SHALL BE DETERMINED BY SUBTRACTING THE WEIGHT OF THE FACTORY BLOCK OUTS FROM THE GROSS STRUCTURE I WEIGHT. THIS INFORMATION SHALL BE SHOWN ON THE SHOP DRAWINGS SUBMITTED TO THE ENGINEER FOR REVIEW. IF THE CONTRACTOR OPTS TO CAST -IN-PLACE THE ANTI -FLOTATION BLOCK, THE CONTRACTOR SHALL ENSURE THE WEIGHT I \ OF THE ENTIRE RISER STRUCTURE IS EQUAL TO THE MINIMUM LISTED ABOVE. 6. THE RISER BOX JOINTS SHALL BE SEALED USING BUTYL RUBBER SEALANT CONFORMING TO ASTM -C990 -LATEST. IF NECESSARY, THE CONTRACTOR SHALL INCORPORATE A WATERSTOP INTO THE RISER BOX JOINT TO ENSURE A WATERTIGHT CONNECTION. THE CONTRACTOR SHALL PARGE JOINTS ON BOTH THE INSIDE AND OUTSIDE WITH NON -SHRINK GROUT. 7. PRIOR TO ORDERING, THE CONTRACTOR SHALL SUBMIT TRASH RACK SHOP DRAWINGS TO THE ENGINEER FOR REVIEW. / CONTRACTOR SHALL ENSURE THAT AN ACCESS HATCH IS PROVIDED WITHIN THE TRASH RACK(SEE DETAIL FOR LOCATION) THAT WILL ALLOW FOR FUTURE MAINTENANCE ACCESS. CONTRACTOR SHALL ALSO PROVIDE A CHAIN AND / LOCK FOR SECURING THE ACCESS HATCH. NOTE THE ACCESS HATCH SHALL LINE UP WITH THE ACCESS STEPS AFTER I / INSTALLATION. / 8. ALL POURED CONCRETE SHALL MEET THE FOLLOWING SPECIFICATIONS UNLESS OTHERWISE NOTED: I / -MINIMUM 3000 PSI (28 DAY) -SLUMP = 3" - 5" -ENTRAINED AIR = 5%- 7% PLEASE NOTE NO CONCRETE SHALL BE POURED WHEN THE AMBIENT AIR TEMPERATURES ARE EXPECTED TO BE ABOVE 85°F OR BELOW 40°F. CAST -IN-PLACE CONCRETE SHALL BE "WET CURED" AFTER FINISHING FOR A MINIMUM OF 48 HOURS. 9. GEOTEXTILE FABRIC FOR THE 24"0 RCP OUTLET BARREL JOINTS SHALL BE MIRAFI 18ON OR ENGINEER APPROVED EQUAL / \ (NON -WOVEN FABRIC) 10. STORMWATER FACILITY EMERGENCY DRAW DOWN IS VIA AN 8"0 PLUG VALVE. THE VALVE SHALL BE A M&H STYLE 1820 X -CENTRIC VALVE OR APPROVED EQUAL. THIS VALVE IS IN ACCORDANCE WITH AWWA C-517, AND SHALL BE OPERABLE FROM TOP OF OUTLET STRUCTURE VIA A HAND WHEEL (SEE DETAIL SHEET SW -A3). THE CONTRACTOR SHALL PROVIDE A REMOVABLE VALVE WRENCH WITH A HAND WHEEL ON TOP FOR OPERATION OF THE 8110 PLUG VALVE. A CHAIN AND LOCK SHALL ALSO BE PROVIDED FOR SECURING THE WRENCH TO THE TRASH RACK. I I / J =867.00 / BW= \ \ \ 56 �0 =8590 �59,50 /w// / 0 �W TW=860.00 / 84 8 r7 0 BW=858.00 i / I / / SEDIMENT 7 \/ / J V A0 \ � v / � / 1 v INV = 852.00 \ / / FOREBAY \ \/§ , / �/ / // I A I I I\ 111 V A \ \\ \ \ RETAINING WALL (TYP.) (DESIGN \ BY OTHERS) FOREBAY , , WEIR SPILLWAY \ CREST = 9 LF V \ TOP OF RIP RAP (CREST) = 851.50 LINER = NCDOT CLASS "B" RIPRAP \ \ \ / 8 � 15" MIN. DEPTH (D50 = 8) I \ \ I I ( / / 848 NOTE: A FILTER BLANKET IS TO BE IIII , INSTALLED BETWEEN THE RIP RAP AND SOIL / FOUNDATION. THE FILTER BLANKET WILL /CONSIST OF A MINIMUM 4" THICK LAYER OF STONE (#57) UNDERLAIN WITH MIRAFI FILTER //STONE 700 OR APPROVED EQUIVALENT / FOREBAY BERM EL. = 852.00 /MINIMUM IBE S FT COMPACTED O i PER "BERM AND SOIL / COMPACTION SPECIFICATIONS" / /CIDco00 CID /TOP OF BANK (TYP.) 100 STREAM BUFFER TYP.) BR .,( TW 6 .00 BW 8 8.0 I / I I I l I h l o/ / l \ I I I I / I I' / STORMWATER CONTROL MEASURE /0 o \ I I I / / MAINTENANCE ACCESS EASEMENT 41 '�I I II I I I ROM EL. /8 51.50 /TO/�852.50 SC�/ o //6 -FT AQUATIC SHELF F S�3 ®6:1 SLOPE (TO BE INSTALLED 0PF / / I / I I I / / / AROUND SWMF PERIMETER)/ / / I I III I I I�I II II \ \ I / I I \ \ / MAIN\ POOL / \ \ PRECAST RISER OUTLET STRUCTURE SHAPE = SQUARE INTERNAL DIMENSIONS = 4 FT. x 4 FT. TOP OF RISER = 856.00 1.0"0 ORIFICE = 853.00 2.25"0 ORIFICE (INVERTED SIPHON) = 852.00 INVERT OUT (24"0 0 -RING RCP) = 846.00 I (SEE DETAIL ON SHEET SW -A2) V \ I I I// 97 LF 24"0 CLASS III O-RING CONCRET ® W� CRADLE '00 I o 1 1 1 (JOINTS WRAPPED WRAPIPED IN 3:1I 3:1 GEOTEXTILE FABRIC)SLOPE SLOPE ENDWAILL PER N/ C/D/OT /S/TD. 8/3 880 / �o M / O I w I I Ivco N wcn CID I v >II A I INV. OUT (24-0 RCP) = 845.00 46 � cn n (SEE DETAIL ON SHEET SW -A3) ao n> 411, 0) oono m � i / C: 00 00 coo r o I I I I I I I \\ I I ro 1Lo 00 I I I I '0 II I� II► � v VELOCITY DISSIPATOR NCDOT CLASS 'B'RIPRAP 84 I / 1121 X 6'W X 22 THICK D50 = 8 ( SEE DETAIL SHEET SW -A4) II I I I I \ \ \ \ \ \ 10, / I O / � ASPHALT \ \ / GREENWAY 1 \ i - 851150 852 CONTRACTOR SHALL LINE OUT CHANNEL WITH NCDOT CLASS 'B' RIPRAP. THERE SHALL BE NO DISTURBANCE TO \ a 848 M� ` / I \ \ FOREBAY WEIR SPILLWAY \ \ ANY EXISTING CHANNEL BANk. A FILTER ` I I CREST = 9 LF \ \ \ \ BLANKET SHOULD BE INSTALLED BETWEEN \ \ TOP OF RIP RAP (CREST) = 851.50 RIPRAP & SOIL FOUNDATION. FILTER H „ BLANKET SHALL CONSIST OF A MINIMUM I � LINER = NCDOT CLASS B RIPRAP / / SEDIMENT I H 4" THICK LAYER OF NCDOT 57 STONE FOREBAY I 15 MIN. DEPTH (D50 = 8) ( UNDERDRAIN WITH MIRAFI FILTER WEAVE \I I I I h \ # I IA /I NOTE: A FILTER BLANKET IS TO BE \ 700 OR APPROVED EQUIVALENT. / INSTALLED BETWEEN THE RIP RAP AND SOIL- / I 1I FOUNDATION. THE FILTER BLANKET WILL CONSIST OF A MINIMUM 4" THICK LAYER OF STONE (#57) UNDERLAIN WITH MIRAFI FILTER \ WEAVE 700 OR APPROVED EQUIVALENT \ / \ FOREBAY BERM EL. = 852.00 8�I MINIMUM WIDTH = 5 FTTO E BERM COMPACTED �AND PERSOIL II / COMPACTION SPECIFICATIONS" �I IINV = 852.00 \ \ \ \1 GRAPHIC SCALE 0 10 20 40 STORMWATER CONTROL MEASURE 'A' PLAN VIEW 1" = 20' 1 inch = 20 ft. FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER (vI�I V � z�00 W O UDC) LU r4 cc Z)ca W z DATE QN DC z G = J ^ � v,or- z / �iC z``'U O O ° U �C = O UDC) CHECKED BY JAA cc Z)ca LU z DATE 11. 26. 2018 SHEET G un ,i ^ � z W 0 O F_ U CARP '�.. <,L.........� 6 oFESS/C SEAL 33782 4 REVISIONS N0. DATE PLAN INFORMATION PROJECT NO. RYN-17010 FILENAME RYN17010-SWA CHECKED BY JAA DRAWN BY JSM/LK SCALE 1" = 20' DATE 11. 26. 2018 SHEET STORMWATER CONTROL MEASURE'A' PLAN VIEW SW -A1 TOP OF DAM EL. = 858.00 100 -YEAR STORM EL. = 856.67 10 -YEAR STORM EL. = 856.04 TOP OF RISER EL. = 856.00 2 -YEAR STORM EL. = 854.54 WQV STORM EL. = 852.95 NORMAL WATER SURFACE EL. (NWSE) = 852.00 `J CONCRETE -� ANTI -FLOTATION BLOCK 8"0 EMERGENCY DIP DRAIN WITH TRASH RACK (SEE DETAIL SHEET SW -A3) 0 0 0 0 O I -t yl6- AP,- d d d 4"0 GRADE 8 STAINLESS STEEL ° CONCRETE LAG SCREW 0 12"X4"X" GALVANIZED STEEL ° STRAP (4 PER RISER JOINT) 3.0 RISER JOINT CONNECTION DETAIL N.T.S. TOP OF HANDWHEEL TO EXTEND NOTES: 1 -FOOT ABOVE TRASH RACK 10 FT. WIDEMINIMUM COMPACTED BERM SECTION 1. REMOVED TOPSOIL SHALL BES! OCKPILED FOR USE IN PLANTING (SEEDING) THE DAM EMBANKMENT TRASH RACK LOCATOION OF (SEE BERM AND SOIL CET SW-Al) TE � SPECIFICATIONS ON SHEET SW -A1 ONCE FINAL GRADES (AS SHOWN ON THE GRADING PLAN) HAVE BEEN ESTABLISHED WITH COMPACTED FILL. PRIOR TO TOPSOIL INSTALLATION, THE CONTRACTOR SHALL SCARIFY THE TOP 2- TO 3 -INCHES OF (SEE DETAIL) EXISTING GROUND = _ _ _ _ _ _ THE BERMN SECTION TO PROMOTE BONDING OF THE TOPSOIL WITH THE COMPACTED FILL. THE PROPOSED GRADE _ I=III=1 I 1=1 I I=1 I=1 I I=1 I I=I I 1=1 II=I II=I 11=1 II I= TOPSOIL DEPTH SHALL RANGE FROM 3 -TO 4 -INCHES ON THE DAM EMBANKMENT. I=11�r--�_ 1.0"0 ORIFICE - I=1 I I=1 I I=1 I I=1 I I=1 I I=1 I I=1 I=I I I=1 I I=1 I I=1 11=1 11=1 I MI I I-1 I I-1 I I -I I I'M Imo.-, = 853.00 -11 I =III=III=1 I I=I I 1=1 I I=I 11=I I I=I I I I I I=I I I=I 11=1 11=1 11=1 I I=I I I=I I=1 I I=I I I=-1 1 I I VELOCITY DISSIPATOR _I=1 I I=1 I I=III=11 I=III=I I I=I I 1=1 I I=1 1=1 I I=III=I I I=I 11=1 11=1I1=1 I I=1 I I=1 I I=III-I I I -I I I -I -� 3 NCDOT CLASS B RIPRAP SIPHON W/ 2.25"0 DRILLED ORIFICE 1 �- _ _ _ _ _ _ MINIMUM DIMENSIONS INV. = 852.00 = 1= I I=1 III=III=1 I I=1 11=1 I I=III=1I1=1 I I=1I1 III=III=III=III=III=III=III=III=III=III=III=III=1 -III-I 11�'I�' 12'L X 6'W X 22" THICK (SEE DETAIL SHEET SW -A3) _- I=III=III=III=I III=III=III=III-III-III=III-I I I -I I -I 11=III=III-III-III=III=III-III-III=III=III d -III=III=III=I il'=1�,� - D50 = 6" _- I=111=I I I=1 I I=I I I=III=� III=1 I I=I I I=1 I I=1 I I=III=III=S;O (MIN) --I I I=1 I I=I1=I I =I I I=I I I= I I=III d I I=III=I -11 I=I I I=III=I I I=III=I TO BE LINED WITH GEOTEXTILE CONCRETE COLLAR = I=III=III=III=I I I =III=III=III= II1=I I I=I I I=1 11=I I I=I 11=II1=I I=I I I=I I I=I I I=I I I=III d I I=III=I I I=I I Ed I I=I iffiI I I=III=III=I I I=I I I=III=III=1 _= - - FABRIC OR EQUIVALENT (TO BE CONSTRUCTED IN __ 1=III=III=III=III=III=III=III=III=III III=III=III=III=III=11 I=III III=III=1 I I=11 I=1 11=1 I I=I I I=1 I I=III=1 i t=1 1=III=111=III=I 11-I 11-1 I I -I 11 -III -ISI_'-' rl�-. (SEE DETAIL SHEET SW -A4) THE FIELD BY THE I=1 I I=1 I I=1 11=1 I I=1 I I=1 11= 1 I I=I I I=II1=I 11=1 -I I I -=I I I=I I I=I I I=III EI 11=1 1=I I IEI I I=I 11=1 11=1 11=1 I Ed 11=1 11=1 I IE -1 I lE III=I 11=I 11=1 I I=I I I=1 11=1 I I -I I I -I 11=1 I I-1 I I�rI CONTRACTOR, SEE DETAIL) _ _ _ _ _ _ _ _ _ _ _ _ _ _1 III=1 I I=III=1 I I=III=III III=1 I =III=III=1 I I=1 I I=III=III=III=1 -III=III=I I I=1 i i=III=III=1 I I=1II=1 I I=111=III=I I 1=III=111'=n,, ENDWALL PER NCDOT STD. 838.80 _- I -III -I I I -I I I-1 I I -I I I -i I I -I I I-1 I I-1 I MI I I-III=III-III _ - - - - - - _ _ _ _ _ _ (SEE ETAIL ON SHEET SW -A3) -\ -= I=1 I I=1 I I=1 I I=1 I I=1 I I=1 I I=1 I I=1 I I=1 I I=1 I I=1 i i=1 I I=1 11=1 11=1 11=1 I I =1 11=1 11=1 11=1 11=1 1=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 -I 11=1 1=III=111=111=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 I I 'r I- _ _ TIN _ _ _ _ _ _ = 1=111III=III=III=1 -III=III=III=III=III=III=III=111,,2" COVER (II-III-III-III-IIIIII-III-III II III=11I=III=I -I I 1=III=I I 1=i 1 I=III=I i I=III=III=II=III EIII=III=III=III=III=III=III=III=III=I I '- _ _ ---------------------------------------- I - _ I I -III -III -I i I -III -III -III -I I I_I I I -I I i-1 I I -III -I III -III -III -III -III -III I11 111 r Ill- 11 Ill- 1=1 =1 11=1 11=I 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11= I -I 97 LF CLASS III 24"0 0 -RING RCP- ------- -------------- -------------------- - - - - =Aq C 4 FLOW --�� - - - - - - - - - - - - - - - - - - - - - - - (ASTM C76 -LATEST) ® 1.039 - - - o 0 ° d d ° 4 ° a ° °a ° ° ° A ° - -- -- - - -^ - °d d - - - - - - - - - - - - - -. - - - - - - 9- = - = - - - - - - d 4 I 4 d d° - - - - - - - - - - - °- - - ° d d 4 ° ° d d -zl .�\ \\\ \2.0� (MIN / \ \ 24 CLASS IIID -RING RCP,' ////////////////////////////////////////////////// \INV. = 846.00 \\ \\ \\ \\ \\ \\ \\\ \\\ \\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\\ THICK JpTINT / / / / / / / / //\/\/\/\/\/\/\/\/\/\/\/\/\ \ 5 FT. WIDE MINIMUM \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\x \\ \\ \\ \\ \\ \\\ \\\ \\\ \\\ \\\ \\\ \ \\\ \\\ \\\ \ \\\ \\\ \\\ \\ \\ \\ \\ \ `FILLER MATERIAL \ \\ \\ \\ \\ \\\ \\\ \\\ \\\ \\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\/\\/\\/\\/\\/\\/ \/ \/ \/ \/ \/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\ \/\/\/ / A DOUBLE LAYER OF NON -WOVEN //\//\ (SEE BERM AND SOIL COMPACTION ///\//\//\//\//\//\//\//\//\//\//\//\//\//\//\//\//\/\/\/\/\/\\/\\/\\/\\/\\ \ GEOTEXTI LE FABRIC SHALL BE PLACED \/\\/\\ \/�\ SPECIFICATIONS, DETAIL SHEET SW-A1)i\/\\/\\/\\/\\/\\/\\/\\/\\//\\//\\//\\//\\//\\//\\//\\//\//%\//\ AROUND EACH JOINT OF EACH 24"us O-RING RCP //\//i //i ,, CONCRETE CRADLE \ KEY TRENCH TO BE PROVIDED PER THE ` `����\\\ �\ �\ �\ �\ �� / BARREL IN 2' WIDE STRIPS CENTERED ON JOINT. (SEE DE AIL ON SHEET SW -A4) CONTRACTOR SHALL FORM INVERT OF DIRECTION OF THE SITE GEOTECHNICAL ENGINEER RISER STRUCTURE TO DRAIN POSITIVELY TO INVERT OF OUTLET BARREL USING PERMANENT DAM CROSS SECTION NON -SHRINK GROUT N.T.S. NOTES: 1. CONCRETE ANTI -FLOTATION BLOCK TO BE PROVIDED WITH MINIMUM TEMPERATURE AND SHRINKAGE STEEL REINFORCEMENT. 2. TRASH RACKS NOT SHOWN FOR CLARITY. 3. THE NUMBER OF GUIDES FOR THE VALVE STEM SHALL BE DETERMINED IN THE FIELD BY THE CONTRACTOR. THE VALVE STEM MUST BE OPERABLE FROM THE TOP OF THE RISER VIA THE HANDWHEEL WITH AN INSIGNIFICANT AMOUNT OF PLAY IN THE VALVE STEM. 4. CONTRACTOR SHALL PROVIDE A JOINT IN THE OUTLET BARREL NO MORE THAN 5 -FT FROM THE RISER. 1.0"0 ORIFICE INV. = 853.00 SIPHON W/ 2.25"0 DRILLED ORIF INV. = 852 (SEE DETAIL SHEET SW-, 8" DIP DRAIN W/ TRASH RACK (SEE DETAIL SHEET SW -A3; 25" CONCRETE ANTI -FLOTATION I CONTRACTOR SHALL FORM 1.. , RISER STRUCTURE TO DRAIN POSITIVELY TO INVERT OF OUTLET BARREL USING NON -SHRINK GROUT 8.00' PRECASTER SHALL PROVIDE A BLOCK OUT FOR THE 24"0 0 -RING RCP d- d[1 ° CONCRETE COLLAR °. a d (TO BE CONSTRUCTED IN THE 1.50' 1.50' ° 5.00' 4 1'5� 1 FIELD E CNTRACTOR SEE DETAIL) - d „ °. ° °_.�- CONCRETE CRADLE 8 DIP DRAIN W/ TRASH RACK (SEE: DETAIL SHEET SW -A3) d d ° .a a (SEE DETAIL ON SHEET SW -A4) 0 d - - - - - - - - - 4° 8.00' 5.00' ° d 24"0 0 -RING RCP d FLOW -�- ° SIPHON W/ 2.25"0 DRILLED ORIFICE d ° 4,1 INV. 852.00 -------- (SEE DETAIL SHEET SW -A3) ° 4 a . 1.0"0 ORIFICE ° ° INV. = 853.00 4 .v 1.50' d 4 .Q ° . ° ° _ d d a ° 1" THICK JOINT FILLER MATERIAL ° . d (TYP.) ° 4 8"0 PLUG VALVE. THE VALVE SHALL BE A M&H _j STYLE 820 X -CENTRIC VALVE OR APPROVED EQUAL. THIS VALVE SHALL BE IN ACCORDANCE WITH AWWA C-504 SEC. 5.5, AND SHALL BE OPERABLE FROM TOP OF HANDWHEEL TO EXTEND TOP OF OUTLET STRUCTURE VIA A HANDWHEEL. 1 -FOOT ABOVE TRASH RACK CONTRACTOR SHALL PROVIDE STEPS IN nnKITonrTOR SHALL PROVIDE STEPS IN ACCORDANCE WITH NCDOT STD. 840.66. JCE WITH NCDOT STD. 840.66. STEPS SHALL BE PLACED AT 16" O.C. CONTRACTOR SHALL PROVIDE STEPS IN ALL BE PLACED AT 16" O.C. (SEE DETAIL ON SHEET SW -A3) ACCORDANCE WITH NCDOT STD. 840.66. STEPS SHALL BE PLACED AT 16" O.C. IIIL ON SHEET SW -A3) TOP OF RISER EL. = 856.00 (SEE DETAIL ON SHEET SW -A3) VALVE STEM GUIDE (SEE NOTE #3) a_ 10.00' 12.58' 1.0"0 ORIFICE INV. = 853.00 SIPHON W/ 2.25"0 DRILLED ORIFICE INV. = 852.00 (SEE DETAIL SHEET SW -A3) rA PRECASTER SHALL PROVIDE A BLOCK OUT FOR THE 24"0 0 -RING RCP CONCRETE COLLAR 4 d (TO BE CONSTRUCTED IN THE FIELD BY ° THE CONTRACTOR - SEE DETAIL) o ° ° d r------- - - - - - - - - - a, ° 24"0 0 -RING RCP 4 FLOW -� 8" DIP DRAIN W/ TRASH RACK ° (SEE DETAIL SHEET SW -A3) ° d INVERT OUT EL. = 846.00 a - _ 4- 0.50' 4 . ° ° -f ° d 4 ° a 2.08'4 ° ° 4 d a d ° CONCRETE CRADLE ° .4 d d (SEE DETAIL ON ° ° 4 SHEET SW -A4) CONCRETE ANTI -FLOTATION BLOCK ° 1 " THICK JOINT FILLER MATERIAL CONTRACTOR SHALL FORM INVERT OF RISER STRUCTURE TO DRAIN POSITIVELY TO INVERT OF OUTLET BARREL USING NON -SHRINK GROUT PERMANENT OUTLET STRUCTURE DETAILS N.T.S. 7.0' 5.0' 3.0' 7.0' 1.0' (TYP.) D 9.9 LF J 2"x2"x1/4" ANGLE THE BOLD / DASHED LINETYPE DENOTES THE ACCESS HATCH TO BE PROVIDED BY THE TRASH RACK FABRICATOR PER OUTLET STRUCTURE MATERIAL SPECIFICATIONS (SHEET SW -81) NOTES: 1. ALL REBAR TO BE #4 REBAR. 3" CLEARANCE - TO OUTSIDE OF #4 REBAR) 3.625' 0.5' ANCHOR DEPTH 5.0' 3" CLEARANCE TO OUTSIDE OF #4 REBAR) .d d ° ° ° ° d I 24" 0 -RING RCP ° CONCRETE ANCHOR BOLT (TYP., SEE NOTE #4) 9.9 LF 2"x2"x1/4" ANGLE 2.0' �/- CONCRETE ANCHOR BOLT (TYP., SEE NOTE #4) FABRICATED HINGES FOR THE 2'x3' ACCESS HATCH. ACCESS HATCH SHALL BE POSITIONED OVER STEPS. 9.9 LF 2"x2"x1/4" ANGLE RISER TRASH RACK DETAIL N.T.S. 3" CLEARANCE TO OUTSIDE OF #4 REBAR) 4" 3.8' 4" (CENTER TO (CENTER TO (CENTER CENTER) CENTER) CENTEF ANTI -FLOTATION BLOCK 1.0' / 24" CLASS III O-RING RCP / INVERT EL. 845.00 SPILLWAY FILTER (SEE DETAIL SHEET SW -A3) 0.7' 2.0' (TYP) NOTES: 1. ALL REBAR TO E E #4 REBAR. 2. ALL REBAR AND ANGLES TO BE HOT -DIPPED GALVANIZED AND BE PROVIDED WITH AN EPDXY COATING. 3. THE HOT -DIPPED, GALVANIZED 2"x2"x1/4" ANGLES SHALL BE WELDED TO THE REBAR TRASH RACK. ONCE WELDED, THE ENTIRE ASSEMBLY SHALL BE PLACED ONTO THE RISE I WITH ANGLES SITTING DIRECTLY ON TOP OF RISER. 4. CONTRACTOR SHALL ANCHOR THE TRASH RACK TO MANHOLE WALL WITH FOUR 4"x1/4" CONCRETE ANCHOR BOLTS THROUGH ANGLES. 5. CONTRACTOR SHALL OMIT OR ADJUST REBAR AS NECESSARY TO ALLOW FOR CONCRETE COLR. 6. ACCESS HATCH SHALL ALIGN WITH STEPS IN RISER. 3" ANCHOR DEPTH 1' DEPTH PRECAST STRUCTURE WALL 3000 PSI CONCRETE COLLAR (MIN. 28 DAY STRENGTH) 3" CLEARANCE TO OUTSIDE OF #4 REBAR) #4 REBAR ANCHORS.---/ - - - - CONTRACTOR SHALL DRILL INTO PRECAST STRUCTURE WALL AND SET ANCHORS USING ° 24" 0 -RING EPDXY GROUT RCP 5.5" CENTER TO T4 JCENTER ° 6" ANCHOR DEPTH 4 d4 a d #4 REBAR ANCHORS. 3" CLEARANCE CONTRACTOR SHALL DRILL TO OUTSIDE OF INTO PRECAST BASE AND SET #4 REBAR) ANCHORS USING EPDXY GROUT CONCRETE COLLAR DETAIL N.T.S. SIDE VIEW J The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER RYN17010-SWA CHECKED BY JAA DRAWN BY d SCALE N.T.S. DATE z�00 SHEET 4 Uj r4Uj W Q OC z Q ° a Uj Q �z-U o0�= d 4 0 U0z 4" 3.8' 4" (CENTER TO (CENTER TO (CENTER CENTER) CENTER) CENTEF ANTI -FLOTATION BLOCK 1.0' / 24" CLASS III O-RING RCP / INVERT EL. 845.00 SPILLWAY FILTER (SEE DETAIL SHEET SW -A3) 0.7' 2.0' (TYP) NOTES: 1. ALL REBAR TO E E #4 REBAR. 2. ALL REBAR AND ANGLES TO BE HOT -DIPPED GALVANIZED AND BE PROVIDED WITH AN EPDXY COATING. 3. THE HOT -DIPPED, GALVANIZED 2"x2"x1/4" ANGLES SHALL BE WELDED TO THE REBAR TRASH RACK. ONCE WELDED, THE ENTIRE ASSEMBLY SHALL BE PLACED ONTO THE RISE I WITH ANGLES SITTING DIRECTLY ON TOP OF RISER. 4. CONTRACTOR SHALL ANCHOR THE TRASH RACK TO MANHOLE WALL WITH FOUR 4"x1/4" CONCRETE ANCHOR BOLTS THROUGH ANGLES. 5. CONTRACTOR SHALL OMIT OR ADJUST REBAR AS NECESSARY TO ALLOW FOR CONCRETE COLR. 6. ACCESS HATCH SHALL ALIGN WITH STEPS IN RISER. 3" ANCHOR DEPTH 1' DEPTH PRECAST STRUCTURE WALL 3000 PSI CONCRETE COLLAR (MIN. 28 DAY STRENGTH) 3" CLEARANCE TO OUTSIDE OF #4 REBAR) #4 REBAR ANCHORS.---/ - - - - CONTRACTOR SHALL DRILL INTO PRECAST STRUCTURE WALL AND SET ANCHORS USING ° 24" 0 -RING EPDXY GROUT RCP 5.5" CENTER TO T4 JCENTER ° 6" ANCHOR DEPTH 4 d4 a d #4 REBAR ANCHORS. 3" CLEARANCE CONTRACTOR SHALL DRILL TO OUTSIDE OF INTO PRECAST BASE AND SET #4 REBAR) ANCHORS USING EPDXY GROUT CONCRETE COLLAR DETAIL N.T.S. SIDE VIEW J The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER �N CAR04�'�'% 9. i 2 o •FESS% _ SEAL _ 33782 'ygAt A. REVISIONS N0. DATE PLAN INFORMATION PROJECT NO. RYN-17010 FILENAME RYN17010-SWA CHECKED BY JAA DRAWN BY V SCALE N.T.S. DATE z�00 SHEET Uj r4Uj W Q OC z Q Q cc Uj Q �z-U o0�= 0 U0z Z W Q G V z o O U �N CAR04�'�'% 9. i 2 o •FESS% _ SEAL _ 33782 'ygAt A. REVISIONS N0. DATE PLAN INFORMATION PROJECT NO. RYN-17010 FILENAME RYN17010-SWA CHECKED BY JAA DRAWN BY JSM SCALE N.T.S. DATE 11. 26. 2018 SHEET CONCRETE ANTI -FLOTATION BLOCK STORMWATER CONTROL MEASURE 'A' DETAILS SWmA FINAL DRAWING -NOT RELEASED FOR CONSTRUCTION z J L Y ct 0 m 0 #6 REBAR PERIMETER FRAME 4" x 4" 6/6 WELDED WIRE FABRIC (EACH SIDE & TOP OF CAGE) 18" (TYP.) 2.03' 2 LF 8"0 DIP a u ° 4 a a 4" ANCHOR DEPTH CONTRACTOR SHALL DRILL INTO PRECAST ° EXTENDED BASE AND SET ANCHORS USING EPDXY GROUT 0.86' (CENTER TO CENTER) V 4" x 4" 6/6 WELDED WIRE--, FABRIC (EACH SIDE & TOP OF CAGE) CONTRACTOR SHALL SEAL THE PIPE PENETRATION USING A RUBBER BOOT AND STAINLESS STEEL HARDWARE ° ��-8" PLUG VALVE. THE VALVE SHALL BE A M&H STYLE 1820 X -CENTRIC VALVE OR ° ENGINEER APPROVED EQUAL. a THIS VALVE SHALL BE IN ACCORDANCE WITH AWWA C-517, AND SHALL BE d� a OPERABLE FROM TOP OF 2.00' OUTLET STRUCTURE VIA A HANDWHEEL. #6 REBAR PERIMETER FRAME 8"0 DIP DRAIN PIPE CONTRACTOR SHALL CORE -DRILL THE HOLE FOR THE 8"0 DIP IN THE FIELD. PRECASTER SHALL OMIT REINFORCEMENT IN THIS AREA. 8"0 EMERGENCY DIP DRAIN TRASHRACK DETAILS NOTES: 1. CONTRACTOR SHALL PROVIDE A JOINT IN THE OUTLET BARREL. NO MORE THAN 5 -FT FROM THE RISER. 1" THICK JOINT FILER; MATERIAL ° a d. 4 d Q a 4 d d ® 4 a a' 4 Q. fid. 24"0 0 -RING RCP FLOW Q d N.T.S. J a NOTES: INSTALL ALL STEPS PROTRUDING 4 FROM INSIDE FACE OF STRUCTURE WALL. STEPS DIFFERING IN DIMENSIONS, CONFIGURATION, OR MATERIALS FROM THOSE SHOWN MAY ALSO BE USED PROVIDED THE CONTRACTOR HAS FURNISHED Z O Q ° a THE ENGINEER WITH DETAILS OF THE PROPOSED STEPS AND HAS RECEIVED WRITTEN APPROVAL FROM THE ENGINEER FOR �a. Q 3 77�pp MIN./MAX. MIN./MAX. "pC(DU ° PIPE DIA. BAR a U_ _j � Z rmiZ -I= D D (FT.) W1 W2 0 co Occz - F,= @ 8" 1' d ° a a 1 8"0 DIP DRAIN PIPE CONTRACTOR SHALL CORE -DRILL THE HOLE FOR THE 8"0 DIP IN THE FIELD. PRECASTER SHALL OMIT REINFORCEMENT IN THIS AREA 6" MIN. WALL 8" PLUG VALVE. THE VALVE THICKNESS SHALL BE A M&H STYLE 1820 X -CENTRIC VALVE OR APPROVED EQUAL. THIS VALVE SHALL BE IN ACCORDANCE WITH AWWA C-517, AND SHALL BE OPERABLE FROM TOP OF OUTLET STRUCTURE M n VIA A HANDWHEEL. CONCRETE COLLAR (SEE DETAIL SHEET SW -A2) - 2 LF 8"0 DIP CONTRACTOR SHALL SEAL THE PIPE PENETRATION USING A RUBBER BOOT AND STAINLESS STEEL HARDWARE 24"0 0 -RING RCP FLOW -� a d d p d Q THICK 1" THICK JOINT FILLER MATERIAL FILLER MATERIAL CONCRETE ANTI -FLOTATION/ TOP VIEW BLOCK SIDE VIEW CONCRETE _/ ANTI -FLOTATION BLOCK RISER BARREL/CRADLE CONNECTION DETAIL N.T.S. 4" PVC CAF SCREW TYPE TOP EL. = 853.00 INVERT THROUGH RISER EL. = 852.00 BOTTOM EL. = 851.50 4" PVC CAP WITH 2.25"0 DRILLED ORIFICE SIPHON OUTLET DETAIL N.T.S. RISER OUTLET STRUCTURE L' 4 d 4"0 PVC SIPHON INVERT EL. = 852.00 (NWSE) vm NOTES: INSTALL ALL STEPS PROTRUDING 4 FROM INSIDE FACE OF STRUCTURE WALL. STEPS DIFFERING IN DIMENSIONS, CONFIGURATION, OR MATERIALS FROM THOSE SHOWN MAY ALSO BE USED PROVIDED THE CONTRACTOR HAS FURNISHED Z O Q H ' Z THE ENGINEER WITH DETAILS OF THE PROPOSED STEPS AND HAS RECEIVED WRITTEN APPROVAL FROM THE ENGINEER FOR THE USE OF SUCH STEPS. Q 3 77�pp MIN./MAX. MIN./MAX. "pC(DU F- O Cn PIPE DIA. BAR SIZE U_ _j � Z rmiZ -I= D D (FT.) W1 W2 0 co Occz - ?�1Z>m @ 8" 1' 2.00/3.75 ¢V��►�+ =C/15O "n 1 1.25 #5 F-= Zw :a" a r- c�G)O" - 1.25/2.00 m C/3 LL 0 _j ".< p0CD CC 1.50 #5 @ B" 1.25/2.00 3.00/4.25 (/y • r„i" -� tl�"j 6.50/6.75 d � r w O z I 4.00/4.75 � 4.00/4.25 7.50/8.25 2.5 #5 1.' 1. - PLAN SIDE 2.00/3.00 4.50/5.50 10.00/11.50 3.0 ELEVATION @ 8" 3.00/3.50 PLAN SIDE 2.75/3.50 - 11.50/11.75 3.5 ELEVATION @ 8" 3.25/4.50 6.00/6.75 3.25/3.50 6.00/6.75 12.00/13.25 4.0 #5 @ B" 8" 6.5017.00 3.25/3.50 N 13.00/13.25 4.5 #5 @ 8" 0. 0 -4 3.25/4.00 141t 13.50/15.75 Uj w H Z 1 > G7 1 ° CAST IRON 4.50/5.00 CAST IRON z N L7 = ELEVATION ELEVATION #5 LU cc M� 7.50/8.50 3.25/4.00 7.25/9.25 14.00/15.75 Z 1g° @ 8" 4.50/5.00 p ci D#6 7.75/9. - BAR OR w v -�' #6 BAR GALV D. o z JAW :~/� _1 T�a LTJ M� z CA POLYPROPYLENE J N 4 .,1 PLAN SIDE PLASTIC ELEVATION SIDE ELEVATION c7 w N �- : �� COMPOSITE PLAN 7/ n REINFORCING STEEL 12" ELEVATION #3 DEFORMED 12 NOTE: DO NOT USE IN STEEL ROD SECTION A -A ELEVATION SANITARY SEWER MANHOLES. SHEET 1 OF 1 SHEET 1 OF 1 840.66 840.66 'a m z M 0 Znr M Cl) = N (n D = O z C=ZD -400 v N M 'q vM -UM> m M z Z � �aQ Cj) r m r 838.80 W1 FT.) r I 1 I 1-0" PLAN CA MAINTENANCE ACCESS STEPS N.T.S. z 0� H � NOTES: Q 3 . D 6" cjo * THIS PRECAST ENDWALL MAY BE USED FOR THE FOLLOWING H STANDARDS: 8II1,8 838.11, 838.21, 838.27, 838.33, 0 J a :r 838.39, 838.51, 838.57, 838.63 AND 838.69. O lx 07 = * INSTALL PRECAST ENDWALLS WITH WINGS AND PAY w << LL:r FOR IN ACCORDANCE WITH SPECIFICATION SECTION 638. ,~S V = H USE 4000 PSI CONCRETE. F- S ~ Z w - * PROVIDE ALL REINFORCING STEEL WHICH MEETS ASTM A615 � O O 0 a FOR GRADE 60 AND WELDED WIRE FABRIC CONFORMING O I TO ASTM A185 WITH 2" MIN. CLEARANCE. Z H H2 * PLACE LIFT HOLES OR PINS IN ACCORDANCE WITH H OSHA STANDARD 1926.704. , W H1 I PIPE TO BE GROUTED INTO HEADWALL AT JOB SITE BY C) CONTRACTOR ALL ELEMENT PRECAST TO MEET ASTM C913. WELDED WIREFABRIC MAY BE SUBSTITUTED FOR REBAR AS LONG A3 THE SAME AREA OF STEEL IS PROVIDED. * CHAMFER ALL ORNERS 1" OR HAVE A RADIUS OF 1". B" O.C.(TYP.) REFER TO CHART W FOR BAR SIZE NOTE: THE MINIMUM BAR SIZE SHALL BE #5 BARS �Y AT 8" CTS.THE CONTRACTOR WILL HAVE THE OPTION SIDE TO INCREASE THIS BAR SIZE AS NEEDED. LL Q H Z OUTLET ENDWALL DETAILS N.T.S. 25 14.75(16.75 Q W a cc o W a 0 LU cm F- = h � V � Q Z H O 47 N = H cn Cl) w CD J 'd► Ly' Z w W i 0 LL J s The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER ENDWALL DIMENSIONS V FT. MINIMUM MIN./MAX. MIN./MAX. MIN./MAX. MIN./MAX. MIN./MAX. PIPE DIA. BAR SIZE H1 (FT.) H2(FT.) D (FT.) W1 W2 1.0 #5 @ 8" 1.25/2.00 2.00/3.75 1.25/1.75 3.0013.75 5.50/6.00 1.25 #5 @ 8" 1.2512.00 3.00/3.75 1.25/2.00 3.50/3.75 6.50/6.75 1.50 #5 @ B" 1.25/2.00 3.00/4.25 1.50/2.50 3.50/3.75 6.50/6.75 2.0 #5 @ 8" 1.50/2.50 4.00/4.75 1.75/2.50 4.00/4.25 7.50/8.25 2.5 #5 @ 8" 2.5013.50 4.00/6.00 2.00/3.00 4.50/5.50 10.00/11.50 3.0 #5 @ 8" 3.00/3.50 5.0016.00 2.75/3.50 5.25/5.75 11.50/11.75 3.5 #5 @ 8" 3.25/4.50 6.00/6.75 3.25/3.50 6.00/6.75 12.00/13.25 4.0 #5 @ B" 3.50/4.50 6.5017.00 3.25/3.50 6.50/6.75 13.00/13.25 4.5 #5 @ 8" 4.00/5.00 6.50/8.50 3.25/4.00 7.00/9.25 13.50/15.75 5.0 #5 @ 8" 4.50/5.00 7.0018.50 3.25/4.00 7.25/9.25 13.75/15.75 5.5 #5 @ 8" 4.50/5.00 7.50/8.50 3.25/4.00 7.25/9.25 14.00/15.75 6.0 #5 @ 8" 4.50/5.00 7.50/8.50 3.2514.00 7.75/9. OUTLET ENDWALL DETAILS N.T.S. 25 14.75(16.75 Q W a cc o W a 0 LU cm F- = h � V � Q Z H O 47 N = H cn Cl) w CD J 'd► Ly' Z w W i 0 LL J s The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER REVISIONS NO. DATE PLAN INFORMATION PROJECT NO. RYN-17010 SHEET 1 OF 1 1838.80 FILENAME RYN17010-SWA CHECKED BY IAA DRAWN BY JSM SCALE N.T.S. DATE 11. 26. 2018 SHEET STORMWATER CONTROL MEASURE 'A' DETAILS FINAL DRAWING -NOT RELEASED FOR CONSTRUCTION V Q00 00 W N W 3 Q Q DC z Q N O - LU Q z U _ O O S o X00 r W Q z W O U REVISIONS NO. DATE PLAN INFORMATION PROJECT NO. RYN-17010 SHEET 1 OF 1 1838.80 FILENAME RYN17010-SWA CHECKED BY IAA DRAWN BY JSM SCALE N.T.S. DATE 11. 26. 2018 SHEET STORMWATER CONTROL MEASURE 'A' DETAILS FINAL DRAWING -NOT RELEASED FOR CONSTRUCTION NOTES: 1. A FILTER BLANKET IS TO BE INSTALLED BETWEEN THE RIPRAP AND SOIL FOUNDATION. THE FILTER BLANKET WILL CONSIST OF A MINIMUM 4" THICK LAYER OF STONE (NCDOT #57) UNDERLAIN WITH MIRAFI FILTER WEAVE 700 OR APPROVED EQUIVALENT ENDW/ NCDOT STD. 24"0 0–RING RCP A} 12' PLAN NCDOT CLASS "B" RIPRAP 121 x 6'W x 22" THICK JA FILTER BLANKET (SEE NOTE) OUTLET BARREL VELOCITY DISSIPATOR N.T.S. (2) 4" PERFORATED, CORRUGATED HDPE PIPE (ADS N-12 OR APPROVED EQUIVALENT) 24"0 0–RING RCP ENDWALL PER NCDOT STD. 838.80 SECTION A -A NOTE: 1. AS AN ALTERNATE TO A CONCRETE CRADLE UNDER THE BARREL PIPE (THIS DETAIL), THE CONTRACTOR MAY CHOOSE TO ELIMINATE THE CONCRETE CRADLE AND USE COMPACTED BACKFILL IF THE ON-SITE GEOTECHNICAL ENGINEER WILL PROVIDE A NC PE SEALED LETTER CERTIFYING THAT THE COMPACTION UNDER, AROUND, AND ABOVE THE BARREL MEETS THE SPECIFICATIONS OF THE EMBANKMENT COMPACTION REQUIREMENTS AND MOISTURE CONTENT. THIS CERTIFICATION LETTER MUST BE SUBMITTED TO THE DESIGN ENGINEER BEFORE AS -BUILT CERTIFICATION OF THE FACILITY. THIS SEPARATE CERTIFICATION MUST BE SPECIFIC TO THE BARREL PIPE FOR THE FACILITY, AND MUST CLEARLY STATE THAT ALL SOIL MATERIAL UNDER, AROUND, AND ABOVE THE BARREL PIPE MEETS THE BERM AND SOIL COMPACTION SPECIFICATIONS STATED ON SHEET SW -A1. THIS CERTIFICATION IS TO INCLUDE REFERENCE TO BOTH MATERIAL AND COMPACTION, AND MUST STATE THAT ALL MATERIALS UNDER, AROUND, AND ABOVE THE BARREL HAVE BEEN COMPACTED PER THE BERM MATERIAL SPECIFICATIONS (AT LEAST 95% OF MAXIMUM DRY DENSITY USING ASTM D698 STANDARD PROCTOR) WITH NO VOID SPACES PRESENT. THE CONTRACTORS INTENT TO UTILIZE THIS ALTERNATIVE MUST BE STATED PRIOR TO CONSTRUCTION TAKING PLACE. THIS CONTRACTORS CERTIFICATION MUST BE PRESENTED TO THE DESIGN ENGINEER BEFORE AN AS -BUILT CERTIFICATION CAN BE ISSUED FOR THIS FACILITY. BARREL PIPE FLOWABLE FILL CRADLE CONSTRUCTION SEQUENCE 1. CONSTRUCT FORMWORK FOR FLOWABLE FILL CRADLE ON EXISTING GRADE. 2. EXCAVATE TRENCH FOR CRADLE AND BARREL PER DIMENSIONS ON DRAWINGS. 3. PLACE BARREL PIPE ON CONCRETE BLOCKS TO GRADE. CONTRACTOR SHALL WRAP JOINTS WITH 2 -FT WIDE STRIPS OF FABRIC AT THIS STEP. T22" LAYER OF 4. PLACE PLOWABLE FILL FOR CRADLE FOR EACH SECTION FROM ONE SIDE OF THE TRENCH. ALLOW PLOWABLE CLASS B" RIPRAP FILL TO FILL ENTIRE AREA UNDER PIPE AND PIPE HAUNCHES AS TO LEAVE NO VOIDS UNDER THE PIPE BEFORE 4 FILTER BLANKET PLACING FLOWABLE FILL ON THE OPPOSITE SIDE OF THE TRENCH. PLACE ENTIRE CRADLE AS ONE LIFT (VERTICALLY) PER DRAWINGS. 5. FLOWABLE FILL CRADLE MAY BE ELIMINATED PER RECOMMENDATION FROM THE ON-SITE GEOTECHNICAL ENGINEER. ANY DEVIATION FROM THIS DETAIL SHALL BE SUBMITTED TO AND REVIEWED BY THE DESIGN ENGINEER PRIOR TO IMPLEMENTATION. IF THE CRADLE IS ELIMINATED, THEN A LETTER FROM AN NC PE CERTIFYING THAT ALL SOIL MATERIAL UNDER, AROUND, AND ABOVE THE BARREL PIPE MEETS THE BERM MATERIAL SPECIFICATIONS STATED ON SHEET SW -A1 IS REQUIRED. 6. ALLOW CRADLE TO CURE FOR A MINIMUM OF 7 DAYS BEFORE ANY VIBRATING COMPACTION EQUIPMENT IS USED IN THE VICINITY OF THE BARREL PIPE. 7. TRENCH TO BE BACKFILLED IN 5" LIFTS WHEN COMPACTION IS BY HAND. BACKFILL IS IN 811 LIFTS WHEN CONDUCTED BY MACHINE. MINIMUM OF 2 FEET COVER MUST BE PRESENT ON 24110 RCP BEFORE DRIVING OVER WITH HEAVY EQUIPMENT. ENDWALL PER NCDOT STD. 00� 838.80 NOTE: 4" WEEPHOLES TO BE PROVIDED WITH VARMIT GUARD ON DOWNSTREAM SIDE AND GALVANIZED HARDWARE CLOTH ON UPSTREAM SIDE (Y4" MAXIMUM OPENINGS) rvv. ci rvr�anw Jlvrv� ENCASED IN NON–WOVEN FILTER FABRIC (MIRAFI 180N OR EQUIVALENT) JDWALL PER CDOT STD. 838.80 D, PIPE IY—IL WIN APPROVED EQUIVALENT) ENDWALL PER NCDOT STD. 838.80 40. 67 WASHED STONE ENCASED IN NON–WOVEN GEOTEXTILE FABRIC (MIRAFI 180N OR EQUIVALENT) SPILLWAY FILTER DETAIL N.T.S. ULU I tX I ILt tAUKK: kMIKAI-I 18ON OR EQUIVALENT) `G/ T 1 LI\1 VI\111 LV, CORRUGATED HDPE PIPE (ADS N-12 OR APPROVED EQUIVALENT) 4.5' MIN. 66" MIN. 24" CONCRETE CRADLE DETAIL N.T.S. 1 (MIN.) 1 750 PSI FLOWABLE FILL FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION McADAMS___..�. The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER (vi) or -01V Z LLI �wN C5 –o JAA DRAWN BY 2'-6" O.D. SCALE N.T.S. DATE yo 1 C)1� i i i 24.0 O–RING RCP J �Il Q �G Z OO�coDO� �O�O o jo�� o� o B ° o�o�o�o� 000 o�o�O�o�j z m C? ��o ���o o —� 0 ENDWALL PER NCDOT STD. 00� 838.80 NOTE: 4" WEEPHOLES TO BE PROVIDED WITH VARMIT GUARD ON DOWNSTREAM SIDE AND GALVANIZED HARDWARE CLOTH ON UPSTREAM SIDE (Y4" MAXIMUM OPENINGS) rvv. ci rvr�anw Jlvrv� ENCASED IN NON–WOVEN FILTER FABRIC (MIRAFI 180N OR EQUIVALENT) JDWALL PER CDOT STD. 838.80 D, PIPE IY—IL WIN APPROVED EQUIVALENT) ENDWALL PER NCDOT STD. 838.80 40. 67 WASHED STONE ENCASED IN NON–WOVEN GEOTEXTILE FABRIC (MIRAFI 180N OR EQUIVALENT) SPILLWAY FILTER DETAIL N.T.S. ULU I tX I ILt tAUKK: kMIKAI-I 18ON OR EQUIVALENT) `G/ T 1 LI\1 VI\111 LV, CORRUGATED HDPE PIPE (ADS N-12 OR APPROVED EQUIVALENT) 4.5' MIN. 66" MIN. 24" CONCRETE CRADLE DETAIL N.T.S. 1 (MIN.) 1 750 PSI FLOWABLE FILL FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION McADAMS___..�. The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER (vi) or -01V Z LLI �wN wQ JAA DRAWN BY Qpt=z SCALE N.T.S. DATE yo 1 C)1� J �Il Q �G Z U 00 OU B ° cc Z) (D z m � �-� Q Z 0 o U CARO< _ SEAL ��•' _ 33782 "11.1110 ►"O,,,,�r 1 REVISIONS N0. DATE PLAN INFORMATION PROJECT NO. RYN-17010 FILENAME RYN17010-SWA CHECKED BY JAA DRAWN BY JSM SCALE N.T.S. DATE 11. 26. 2018 SHEET STORMWATER CONTROL MEASURE 'A' DETAILS SW -A4 STORMWATER CONTROL MEASURE 'A' LANDSCAPE SPECIFICATIONS LEGEND QTY. SYM. SCIENTIFIC NAME COMMON NAME HATCH TYPE SPACING SHALLOW LAND 1. CHISEL COMPACTED AREAS AND SPREAD TOPSOIL 3 INCHES DEEP OVER ADVERSE SOIL CONDITIONS, IF AVAILABLE. 2. RIP THE ENTIRE AREA TO 6 INCHES DEPTH. 3. REMOVE ALL LOOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING SURFACE REASONABLY SMOOTH AND UNIFORM. 4. PER ONE TIME ONLY, APPLY AGRICULTURAL LIME, FERTILIZER, AND SUPERPHOSPHATE UNIFORMLY AND MIX WITH SOIL. 5. CONTINUE TILLAGE UNTIL A WELL -PULVERIZED, FIRM REASONABLY UNIFORM SEEDBED IS PREPARED 4 TO 6 INCHES DEEP. 6. SEED ON A FRESHLY PREPARED SEEDBED AND COVER. 7. MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH. 8. INSPECT ALL SEEDED AREAS AND MAKE NECESSARY REPAIRS OR RESEEDINGS WITHIN THE PLANTING SEASON, IF POSSIBLE. AFTER PERMANENT COVER IS ESTABLISHED. 9. CONSULT CONSERVATION INSPECTOR ON MAINTENANCE TREATMENT PERMANENT SEEDING SCHEDULE (DAM EMBANKMENTS) SEEDING DATE SEEDING MIXTURE APPLICATION RATE APRIL 15 - JUNE 30 BERMUDAGRASS 25 LBS/AC SOIL AMENDMENTS APPLY LIME AND FERTILIZER FOLLOWING RECOMMENDATIONS OF SOIL TESTS OR APPLY 3,000 LB/AC GROUND AGRICULTURE LIMESTONE AND 500 LB/AC 10-10-10 FERTILIZER. MULCH APPLY 4000 LB/AC STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE REFERTILIZE THE FOLLOWING APRIL WITH 50 LB/AC NITROGEN. REPEAT AS GROWTH CONTINUES. MAY BE MOWED ONLY ONCE PER YEAR. SEEDING NOTES USE BERMUDAGRASS ONLY ON ISOLATED SITES WHERE IT CANNOT BECOME A PEST. NOTE: PERMANENT SEEDING SCHEDULE IS FOR SLOPES OF THE BASIN, TOP OF BERM, AND BASIN FLOOR. PLANTING INSTRUCTIONS TEMPORARY SEEDING SCHEDULE SEEDING DATE SEEDING MIXTURE APPLICATION RATE JAN 1 - MAY 1 RYE (GRAIN) 120 LBS/AC KOBE LESPEDEZA 50 LBS/AC MAY 1 - AUG 15 GERMAN MILLET 40 LBS/AC AUG 15 - DEC 31 RYE (GRAIN) 120 LBS/AC SOILAMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/AC GROUND AGRICULTURE LIMESTONE AND 750 LB/AC 10-10-10 FERTILIZER (FROM AUG 15 - DEC 31, INCREASE 10-10-10 FERTILIZER TO 1000 LB/AC). MULCH APPLY 4000 LB/AC STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE JAN 1 - AUG 15: REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE, AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. AUG 15 - DEC 31: REPAIR AND REFERTILIZE DAMAGED AREAS IMMEDIATELY. TOP DRESS WITH 50 LB/AC OF NITROGEN IN MARCH. IF IT IS NECESSARY TO EXTEND TEMPORARY COVER BEYOND JUNE 15, OVERSEED WITH 50 LB/AC KOBE LESPEDEZA IN LATE FEBRUARY OR EARLY MARCH. NOTE: USE THE TEMPORARY SEEDING SCHEDULE ONLY WHEN DATE IS NOT CORRECTTO USE THE PERMANENT SEEDING SCHEDULE. II PLANTING TECHNIQUES I A. INSURE THAT ROOTS, ONCE REMOVED FROM POT, ARE STRAIGHTENED AND FACE DOWNWARD. B. CREATE PLANTING AREA FOR EACH PLANT AND EXCAVATE PIT. \ C. PLACE PLANTS IN PIT INSURING ROOTS ARE FACING COMPLETELY DOWNWARD. \ D. HEEL IN SOIL AROUOND PLANT AND PROCEED TO NEXT PLANTING LOCATION. / E. NEWLY PLANTED PLANTS NEED TO BE FASTENED TO THE SUBSTRATE FOR THE ESTABLISHMENT OF NEW ROOTS. F. ROOTS SHALL BE SPREAD IN THEIR NORMAL POSITION. ALL BROKEN OR FRAYED ROOTS HALL BE CUT OFF CLEANLY. G. THE DIAMETER OF THE PITS FOR ALL VEGETATIVE STOCK SHALL BE AT LEAST THREE TIMES THE DIAMETER OF THE ROOT MASS. PLANT PIT WALL SHALL BE \ SCARIFIED PRIOR TO PLANT INSTALLATION. I H. SET THE PLANTS UPRIGHT, IN THE CENTER OF THE PIT. THE BOTTOM OF THE ROOT MASS SHOULD BE RESTING ON UNDISTURBED SOIL. l I. PLACE THE BACKFILL AROUND THE BASE AND SIDES OF THE ROOT MASS, AND WORK EACH LAYER TO SETTLE BACKFILL AND TO ELIMINATE VOIDS AND AIR \ POCKETS. WHEN PIT IS APPROXIMATELY 2/3 FULL, WATER THOROUGHLY BEFORE PLACING REMAINDER OF THE BACKFILL. WATER AGAIN AFTER PLACING I FINAL LAYER OF BACKFILL. I J. BROKEN OR DAMAGED PARTS WILL BE CUT BACK TO UNDAMAGED TISSUE, LEAVING AS MUCH GREEN BASAL TISSUE AS POSSIBLE ABOVE THE ROOTS. IF MORE THAN FIFTY PERCENT (50%) OF THE PLANT IS DAMAGED THEN CONTRACTOR SHALL REPLACE THE PLANT. CONTAINER STOCK / BARE ROOT A. STOCK SHALL HAVE BEEN GROWN IN A CONTAINER LONG ENOUGH FOR THE ROOT SYSTEM TO HAVE DEVELOPED SUFFICIENTLY TO HOLD ITS SOIL TOGETHER ONCE REMOVED FROM THE CONTAINER. I B. CONTAINER PLANTS WILL NEED TO BE WATERED REGULARLY AND PLACED IN SHADY CONDITIONS UNTIL PLANTING OCCURS. I C. BARE ROOT PLANTS ARE FOR IMMEDIATE PLANTING, OTHERWISE SEE D) BELOW. D. IF BARE ROOTS SPECIMENS ARE NOT TO BE PLANTED WITHIN FOUR (4) DAYS, TEMPORARY HOLDING OF BARE ROOT SPECIMENS ARE TO BE COVERED ENTIRELY BY A SUITABLE MEDIUM (ETC. SOIL, SAWDUST, MULCH OR THE LIKE) AND WATERED REGULARLY SO AS TO NOT DRY OUT. PLANT LOCATIONS A. NEW PLANTINGS SHALL BE LOCATED WHERE SHOWN ON PLAN EXCEPT WHERE CHANGES HAVE BEEN MADE IN PROPOSED CONSTRUCTION. B. NECESSARY ADJUSTMENTS SHALL BE MADE ONLY AFTER APPROVAL BY THE OWNER OR THE OWNER'S REPRESENTATIVE. I WATER / WATER SHALL BE POTABLE AND SHALL NOT CONTAIN ELEMENTS TOXIC TO PLANT LIFE. I I I / I / I I =867.00 BW= 8 I / =860.00 =859.0 k / I I I l II 100' STREAM BUFFER (TYP.) ISTORMWATER CONTROL MEASURE MAINTENANCE/ACCESS EASEMENT i %/I III 1111 I I I I IIII I I I I I I I I 11 I II 1, 11 11 I II I I I I S I I S / / I 1 II I I I I II I I I I I 11 I I I I I I IIII (IIIIIIII 11\ I I I I I I I I I IIII 1 1 VA �/ STORMWATER CONTROL MEASURE W LANDSCAPE PLAN 1" = 20' ASPHALT GREENWAY / GRAPHIC SCALE 0 10 20 40 1 inch = 20 ft. FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER (vI�I V � z�00 W UDC) LU r4 cc 392 Al ASCLEPIAS INCARNATE SWAMP MILKWEED z 4 -INCH CONTAINER 24" O.C. DC z G 209 EF EUPATORIADELPHUS JOE PYE WEED D 4 -INCH CONTAINER 24" O.C. FISTULOSUS z 0 0 v 0 0 0 = 214 LC LOBELIA CARDINALIS CARDINAL FLOWER 4 -INCH CONTAINER 24" O.C. SHALLOW WATER 187 IV IRIS VIRGINIANA BLUE FLAG IRIS 4 -INCH CONTAINER 24" O.C. 231 PC PONTEDERIA CORDATA PICKERELWEED ++++ + + + 4 -INCH CONTAINER 24" O.C. 189 ST SCHOENOPLECTUS SOFT -STEM BULRUSH (QD 4 -INCH CONTAINER 24" O.C. TABERNAEMONTANI SEEDBED PREPARATION 1. CHISEL COMPACTED AREAS AND SPREAD TOPSOIL 3 INCHES DEEP OVER ADVERSE SOIL CONDITIONS, IF AVAILABLE. 2. RIP THE ENTIRE AREA TO 6 INCHES DEPTH. 3. REMOVE ALL LOOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING SURFACE REASONABLY SMOOTH AND UNIFORM. 4. PER ONE TIME ONLY, APPLY AGRICULTURAL LIME, FERTILIZER, AND SUPERPHOSPHATE UNIFORMLY AND MIX WITH SOIL. 5. CONTINUE TILLAGE UNTIL A WELL -PULVERIZED, FIRM REASONABLY UNIFORM SEEDBED IS PREPARED 4 TO 6 INCHES DEEP. 6. SEED ON A FRESHLY PREPARED SEEDBED AND COVER. 7. MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH. 8. INSPECT ALL SEEDED AREAS AND MAKE NECESSARY REPAIRS OR RESEEDINGS WITHIN THE PLANTING SEASON, IF POSSIBLE. AFTER PERMANENT COVER IS ESTABLISHED. 9. CONSULT CONSERVATION INSPECTOR ON MAINTENANCE TREATMENT PERMANENT SEEDING SCHEDULE (DAM EMBANKMENTS) SEEDING DATE SEEDING MIXTURE APPLICATION RATE APRIL 15 - JUNE 30 BERMUDAGRASS 25 LBS/AC SOIL AMENDMENTS APPLY LIME AND FERTILIZER FOLLOWING RECOMMENDATIONS OF SOIL TESTS OR APPLY 3,000 LB/AC GROUND AGRICULTURE LIMESTONE AND 500 LB/AC 10-10-10 FERTILIZER. MULCH APPLY 4000 LB/AC STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE REFERTILIZE THE FOLLOWING APRIL WITH 50 LB/AC NITROGEN. REPEAT AS GROWTH CONTINUES. MAY BE MOWED ONLY ONCE PER YEAR. SEEDING NOTES USE BERMUDAGRASS ONLY ON ISOLATED SITES WHERE IT CANNOT BECOME A PEST. NOTE: PERMANENT SEEDING SCHEDULE IS FOR SLOPES OF THE BASIN, TOP OF BERM, AND BASIN FLOOR. PLANTING INSTRUCTIONS TEMPORARY SEEDING SCHEDULE SEEDING DATE SEEDING MIXTURE APPLICATION RATE JAN 1 - MAY 1 RYE (GRAIN) 120 LBS/AC KOBE LESPEDEZA 50 LBS/AC MAY 1 - AUG 15 GERMAN MILLET 40 LBS/AC AUG 15 - DEC 31 RYE (GRAIN) 120 LBS/AC SOILAMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/AC GROUND AGRICULTURE LIMESTONE AND 750 LB/AC 10-10-10 FERTILIZER (FROM AUG 15 - DEC 31, INCREASE 10-10-10 FERTILIZER TO 1000 LB/AC). MULCH APPLY 4000 LB/AC STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE JAN 1 - AUG 15: REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE, AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. AUG 15 - DEC 31: REPAIR AND REFERTILIZE DAMAGED AREAS IMMEDIATELY. TOP DRESS WITH 50 LB/AC OF NITROGEN IN MARCH. IF IT IS NECESSARY TO EXTEND TEMPORARY COVER BEYOND JUNE 15, OVERSEED WITH 50 LB/AC KOBE LESPEDEZA IN LATE FEBRUARY OR EARLY MARCH. NOTE: USE THE TEMPORARY SEEDING SCHEDULE ONLY WHEN DATE IS NOT CORRECTTO USE THE PERMANENT SEEDING SCHEDULE. II PLANTING TECHNIQUES I A. INSURE THAT ROOTS, ONCE REMOVED FROM POT, ARE STRAIGHTENED AND FACE DOWNWARD. B. CREATE PLANTING AREA FOR EACH PLANT AND EXCAVATE PIT. \ C. PLACE PLANTS IN PIT INSURING ROOTS ARE FACING COMPLETELY DOWNWARD. \ D. HEEL IN SOIL AROUOND PLANT AND PROCEED TO NEXT PLANTING LOCATION. / E. NEWLY PLANTED PLANTS NEED TO BE FASTENED TO THE SUBSTRATE FOR THE ESTABLISHMENT OF NEW ROOTS. F. ROOTS SHALL BE SPREAD IN THEIR NORMAL POSITION. ALL BROKEN OR FRAYED ROOTS HALL BE CUT OFF CLEANLY. G. THE DIAMETER OF THE PITS FOR ALL VEGETATIVE STOCK SHALL BE AT LEAST THREE TIMES THE DIAMETER OF THE ROOT MASS. PLANT PIT WALL SHALL BE \ SCARIFIED PRIOR TO PLANT INSTALLATION. I H. SET THE PLANTS UPRIGHT, IN THE CENTER OF THE PIT. THE BOTTOM OF THE ROOT MASS SHOULD BE RESTING ON UNDISTURBED SOIL. l I. PLACE THE BACKFILL AROUND THE BASE AND SIDES OF THE ROOT MASS, AND WORK EACH LAYER TO SETTLE BACKFILL AND TO ELIMINATE VOIDS AND AIR \ POCKETS. WHEN PIT IS APPROXIMATELY 2/3 FULL, WATER THOROUGHLY BEFORE PLACING REMAINDER OF THE BACKFILL. WATER AGAIN AFTER PLACING I FINAL LAYER OF BACKFILL. I J. BROKEN OR DAMAGED PARTS WILL BE CUT BACK TO UNDAMAGED TISSUE, LEAVING AS MUCH GREEN BASAL TISSUE AS POSSIBLE ABOVE THE ROOTS. IF MORE THAN FIFTY PERCENT (50%) OF THE PLANT IS DAMAGED THEN CONTRACTOR SHALL REPLACE THE PLANT. CONTAINER STOCK / BARE ROOT A. STOCK SHALL HAVE BEEN GROWN IN A CONTAINER LONG ENOUGH FOR THE ROOT SYSTEM TO HAVE DEVELOPED SUFFICIENTLY TO HOLD ITS SOIL TOGETHER ONCE REMOVED FROM THE CONTAINER. I B. CONTAINER PLANTS WILL NEED TO BE WATERED REGULARLY AND PLACED IN SHADY CONDITIONS UNTIL PLANTING OCCURS. I C. BARE ROOT PLANTS ARE FOR IMMEDIATE PLANTING, OTHERWISE SEE D) BELOW. D. IF BARE ROOTS SPECIMENS ARE NOT TO BE PLANTED WITHIN FOUR (4) DAYS, TEMPORARY HOLDING OF BARE ROOT SPECIMENS ARE TO BE COVERED ENTIRELY BY A SUITABLE MEDIUM (ETC. SOIL, SAWDUST, MULCH OR THE LIKE) AND WATERED REGULARLY SO AS TO NOT DRY OUT. PLANT LOCATIONS A. NEW PLANTINGS SHALL BE LOCATED WHERE SHOWN ON PLAN EXCEPT WHERE CHANGES HAVE BEEN MADE IN PROPOSED CONSTRUCTION. B. NECESSARY ADJUSTMENTS SHALL BE MADE ONLY AFTER APPROVAL BY THE OWNER OR THE OWNER'S REPRESENTATIVE. I WATER / WATER SHALL BE POTABLE AND SHALL NOT CONTAIN ELEMENTS TOXIC TO PLANT LIFE. I I I / I / I I =867.00 BW= 8 I / =860.00 =859.0 k / I I I l II 100' STREAM BUFFER (TYP.) ISTORMWATER CONTROL MEASURE MAINTENANCE/ACCESS EASEMENT i %/I III 1111 I I I I IIII I I I I I I I I 11 I II 1, 11 11 I II I I I I S I I S / / I 1 II I I I I II I I I I I 11 I I I I I I IIII (IIIIIIII 11\ I I I I I I I I I IIII 1 1 VA �/ STORMWATER CONTROL MEASURE W LANDSCAPE PLAN 1" = 20' ASPHALT GREENWAY / GRAPHIC SCALE 0 10 20 40 1 inch = 20 ft. FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER (vI�I V � z�00 W O UDC) LU r4 cc Z)ca W z SCALE Q DC z G J (� D Z �C z LU v 0 0 0 = O UDC) FILENAME RYN17010-SWA cc Z)ca LU z SCALE 1" = 20' DATE 11. 26. 2018 G un i ^ D Z W 0 O F_ U �N CARO '�.. .........� oFESS/0' '.� SEAL 33782 N A �nnn REVISIONS N0. DATE PLAN INFORMATION PROJECT NO. RYN-17010 FILENAME RYN17010-SWA CHECKED BY JAA DRAWN BY JSM SCALE 1" = 20' DATE 11. 26. 2018 SHEET STORMWATER CONTROL MEASURE 'A' LANDSCAPE PLAN SW -ALS STORMWATER CONTROL MEASURE '6' CONSTRUCTION SPECIFICATIONS GENERAL NOTES 1. PRIOR TO CONSTRUCTION, ANY DISCREPANCIES IN THE PLANS AND NOTES SHALL BE BROUGHT TO THE DESIGN ENGINEER'S ATTENTION IMMEDIATELY. 2. THE FINAL CERTIFICATION FOR THIS FACILITY WILL INCLUDE A CERTIFICATION BY THE ON-SITE GEOTECHNICAL ENGINEER THAT THE PROJECT WAS CONSTRUCTED PER THE APPROVED PLANS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE ON-SITE GEOTECHNICAL ENGINEER FOR OBSERVATION AND TESTING SUCH THAT THE ON-SITE GEOTECHNICAL ENGINEER CAN CERTIFY THE CONSTRUCTION. 3. ALL CONSTRUCTION ACTIVITY RELATED TO THE PROPOSED STORMWATER MANAGEMENT FACILITY SHALL BE PER THE DETAILS AND SPECIFICATIONS SHOWN IN THESE DRAWINGS. SOILS, COMPACTION, AND OTHER MISCELLANEOUS DETAILS AND SPECIFICATIONS MAY BE MODIFIED PER THE RECOMMENDATIONS OF THE ON-SITE GEOTECHNICAL ENGINEER. HOWEVER, PRIOR TO IMPLEMENTATION, THE DESIGN ENGINEER SHALL BE NOTIFIED OF ANY DEVIATION FROM THESE DESIGN DRAWINGS, INCLUDING SHOP DRAWINGS FOR ANY PROPOSED MODIFICATION. 4. THE CONTRACTOR SHALL REFER TO THE LANDSCAPE PLAN FOR THE PERMANENT PLANTING PLAN/SCHEDULE. PLEASE NOTE THAT NO TREES/SHRUBS OF ANY TYPE MAY BE PLANTED ON THE PROPOSED DAM EMBANKMENT (FILL AREAS). 5. DURING THE INITIAL STAGES OF CONSTRUCTION, THE STORMWATER MANAGEMENT FACILITY MAY BE USED AS A SEDIMENT BASIN FOR EROSION CONTROL PURPOSES. IF SO, THE CONTRACTOR SHALL FOLLOW THE GENERAL CONSTRUCTION SEQUENCE BELOW: 5.1. THE CONTRACTOR SHALL CONSTRUCT THE ENTIRE FACILITY (PERMANENT OUTLET STRUCTURE, DAM, ETC.) WITH THE EXCEPTION OF THE INTERIOR FINE GRADING FOR THE FACILITY. THE INTERIOR FINE GRADING WILL BE CONSTRUCTED ONCE THE EROSION CONTROL PHASE IS COMPLETE. 5.2. THE TEMPORARY DRAW DOWN RISER (OR SKIMMER) SHALL BE CONNECTED TO THE PERMANENT 8"0 DIP DRAIN PIPE. 5.3. ONCE THE UPSTREAM DRAINAGE AREA IS STABILIZED AND THE EROSION CONTROL INSPECTOR APPROVES THE REMOVAL OF THE SEDIMENT BASIN, THE CONTRACTOR SHALL REMOVE THE TEMPORARY DRAW DOWN RISER (OR SKIMMER) AND CLEAN-OUT THE BASIN. ALL SEDIMENT, TRASH, ETC. SHALL BE DISPOSED OF PROPERLY (I.E. - PLACED IN A LANDFILL) AND NOT STOCKPILED IN AN AREA WHERE WATER QUALITY COULD BE ADVERSELY AFFECTED. 5.4. ONCE THE BASIN IS CLEANED OUT, AND ALL EROSION CONTROL DEVICES REMOVED, THE CONTRACTOR SHALL CONSTRUCT THE INTERIOR GRADING SHOWN ON THIS SHEET. 5.5. ONCE THE GRADING IS COMPLETE THE CONTRACTOR SHALL REQUEST AN ON-SITE INSPECTION AND AN AS -BUILT SURVEY PRIOR TO INSTALLATION OF THE STORMWATER MANAGEMENT FACILITY PLANTS. IF THE CONTRACTOR PLANTS THE PROPOSED VEGETATION PRIOR TO AN AS -BUILT SURVEY (AND SUBSEQUENT APPROVAL), ANY CHANGES TO THE GRADING / RE -PLANTING OF PLANTS WILL BE AT THE CONTRACTOR'S EXPENSE. 5.6. ONCE THE ENGINEER HAS APPROVED THE AS -BUILT GRADING, THE CONTRACTOR SHALL PLANT THE PROPOSED STORMWATER MANAGEMENT FACILITY PLANTS SHOWN ON THE LANDSCAPE PLAN FOR THE FACILITY. AFTER COMPLETION OF THE PLANTING, THE LANDSCAPE CONTRACTOR SHALL PROVIDE A LETTER TO THE ENGINEER CERTIFYING THAT THE PLANTS HAVE BEEN INSTALLED PER THE APPROVED STORMWATER MANAGEMENT FACILITY PLANTING PLAN. 6. THE GRADES SHOWN ON THIS PLAN ARE FINISHED GRADES. IF THE EXISTING SOIL LAYER ALONG THE FOREBAY BERM IN THE PROPOSED WET POND AFTER CONSTRUCTION / COMPACTION IS NOT DETERMINED SUITABLE BY A LANDSCAPE PROFESSIONAL FOR THE WETLAND PLANTINGS, THEN THE CONTRACTOR SHALL AMEND THE PLANTING AREA OF THE WET POND AS DIRECTED BY A LANDSCAPE PROFESSIONAL. 7. ANY REMOVED TOPSOIL SHALL BE STOCKPILED FOR USE IN PLANTING (SEEDING) ON THE DAM EMBANKMENT ONCE FINAL GRADES (AS SHOWN ON THE GRADING PLAN) HAVE BEEN ESTABLISHED WITH COMPACTED FILL. PRIOR TO TOPSOIL INSTALLATION, THE CONTRACTOR SHALL SCARIFY THE THE TOP 2"-3" OF THE BERM SECTION TO PROMOTE BONDING OF THE TOPSOIL WITH THE COMPACTED FILL. THE TOPSOIL DEPTH SHALL RANGE FROM 3"-4" ON THE DAM EMBANKMENT. PLEASE NOTE THE STOCKPILED TOPSOIL SHALL BE AMENDED, AS DIRECTED BY A LANDSCAPE PROFESSIONAL, PRIOR TO INSTALLATION ON THE EMBANKMENT. 8. IT IS ANTICIPATED THAT DEWATERING WILL BE NECESSARY IN THE EXCAVATION AREAS (E.G. - EMBANKMENT SUB GRADE, INTERIOR PORTIONS OF THE STORMWATER FACILITY, KEY TRENCH, ETC.). THEREFORE, THE CONTRACTOR SHALL FURNISH, INSTALL, OPERATE, AND MAINTAIN ANY PUMPING EQUIPMENT, ETC.. NEEDED FOR REMOVAL OF WATER FROM VARIOUS PARTS OF THE STORMWATER FACILITY SITE. DURING PLACEMENT OF FILL WITHIN THESE AREAS, THE CONTRACTOR SHALL KEEP THE WATER LEVEL BELOW THE BOTTOM OF THE EXCAVATION / CONSTRUCTION AREAS. THE MANNER IN WHICH THE WATER IS REMOVED SHALL BE SUCH THAT THE EXCAVATION BOTTOM AND SIDE SLOPES ARE STABLE, WITH NO SEDIMENT DISCHARGED FROM THE SITE (I.E. PUMPED WATER MAY NEED TO BE DIRECTED TO AN APPROVED EROSION CONTROL DEVICE SUCH AS A DIRT BAG (ACF ENVIRONMENTAL), OR ENGINEER APPROVED EQUIVALENT, PRIOR TO DISCHARGE). 9. THE RETAINING WALL ALIGNMENT SHOWN ON THESE PLANS DEPICTS THE LOCATION OF THE FRONT FACE OF THE RETAINING WALL AT THE BOTTOM. 10. THE RETAINING WALL IS TO BE A DESIGN -BUILD PROJECT(S) BY THE CONTRACTOR. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN FINAL CONSTRUCTION DRAWINGS FROM A REGISTERED PROFESSIONAL ENGINEER AND GAIN ALL REQUIRED PERMITS NECESSARY FOR THE CONSTRUCTION OF THE RETAINING WALL. 11. THE RETAINING WALL SHALL BE ASSUMED TO BE BACKFILLED WITH OFF-SITE BORROW MATERIAL OR PROCESSED FILL UNLESS CONTRACTOR CAN PROVIDE OWNER WITH CONFIRMATION FROM THE GEOTECHNICAL ENGINEER AND THE RETAINING WALL DESIGNER THAT READILY AVAILABLE ON-SITE SOILS CAN BE USED. 12. THE TOP AND BOTTOM OF WALL ELEVATIONS SHOWN ON THESE PLANS IDENTIFY FINISHED GRADE ELEVATIONS ONLY. THE EXTENT THAT THE RETAINING WALL WILL BE EXTENDED BELOW GRADE TO THE FOOTING SHALL BE IDENTIFIED ON THE RETAINING WALL CONSTRUCTION DRAWINGS. BERM AND SOIL COMPACTION SPECIFICATIONS 1. PRIOR TO CONSTRUCTION, THE ON-SITE GEOTECHNICAL ENGINEER SHALL IDENTIFY BORROW / FILL AREAS AND VERIFY THEIR SUITABILITY FOR USE WITHIN THE DAM EMBANKMENT. ALSO, THE ON-SITE GEOTECHNICAL ENGINEER SHALL PERFORM STANDARD PROCTORS ON THE PROPOSED BORROW MATERIAL TO ENSURE THAT OPTIMUM MOISTURE CONTENT AND COMPACTION CAN BE ACHIEVED / CONTROLLED DURING CONSTRUCTION. 2. ALL FILL MATERIALS TO BE USED FOR THE DAM EMBANKMENT SHALL BE TAKEN FROM BORROW AREAS APPROVED BY THE ON-SITE GEOTECHNICAL ENGINEER. THE FILL MATERIAL SHALL BE FREE FROM ROOTS, STUMPS, WOOD, STONES GREATER THAN 6", AND FROZEN OR OTHER OBJECTIONABLE MATERIAL. THE FOLLOWING SOIL TYPES ARE SUITABLE FOR USE AS FILL WITHIN THE DAM EMBANKMENT AND KEY TRENCH: ML AND CL. 3. FILL PLACEMENT FOR THE EMBANKMENT SHALL NOT EXCEED A MAXIMUM 8" LIFT (UNCOMPACTED). EACH LIFT SHALL BE CONTINUOUS FOR THE ENTIRE LENGTH OF EMBANKMENT. BEFORE PLACEMENT OF FILL FOR THE BERM SECTION, ALL UNSUITABLE MATERIAL SHALL BE REMOVED AND THE SURFACE PROPERLY PREPARED FOR FILL PLACEMENT. FILL MATERIAL ADJACENT TO ALL SPILLWAY AND DRAINAGE STRUCTURES SHALL BE PLACED IN 4 -INCH (UNCOMPACTED) LIFTS AND HAND -COMPACTED TO THE SAME COMPACTION AND MOISTURE REQUIREMENTS AS THE ENTIRE EMBANKMENT. 4. ALL FILL SOILS USED IN THE EMBANKMENT CONSTRUCTION SHALL BE COMPACTED TO AT LEAST 95% OF THE STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM -698). THE FILL SOILS SHALL BE COMPACTED AT A MOISTURE CONTENT WITHIN -1 TO +3 PERCENT OF ITS OPTIMUM MOISTURE CONTENT. COMPACTION TESTS SHALL BE PERFORMED BY THE ON-SITE GEOTECHNICAL ENGINEER DURING CONSTRUCTION TO VERIFY THAT THE PROPER COMPACTION LEVEL HAS BEEN REACHED. THE FILL SHOULD BE COMPACTED USING A SHEEPSFOOT TYPE COMPACTOR. IN ORDER TO PREVENT DAMAGE TO THE PIPE, NO COMPACTION EQUIPMENT SHALL CROSS ANY PIPE UNTIL MINIMUM COVER IS ESTABLISHED ALONG THE PIPE. 5. THE DESIGN ENGINEER SHALL BE PROVIDED WITH REPORTS AND CERTIFICATION, BY THE ON-SITE GEOTECHNICAL ENGINEER, THAT THE GEOTECHNICAL ASPECTS OF THE FACILITY HAVE BEEN CONSTRUCTED PER PLAN. THESE REPORTS AND CERTIFICATION WILL BE NEEDED DURING THE AS -BUILT CERTIFICATION PROCESS FOR THIS STORMWATER FACILITY. THEREFORE, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE TESTING AND OBSERVATION WITH THE ON-SITE GEOTECHNICAL ENGINEER. 6. TESTING OF THE NEW FILL MATERIALS SHALL BE PERFORMED TO VERIFY THAT THE RECOMMENDED LEVEL OF COMPACTION IS ACHIEVED DURING CONSTRUCTION. THEREFORE, ONE DENSITY TEST SHALL BE PERFORMED FOR EVERY 2,500 SQUARE FEET OF AREA FOR EVERY LIFT OF FILL OR AS RECOMMENDED BY THE ON-SITE GEOTECHNICAL ENGINEER. 7. TESTING WILL BE REQUIRED ALONG THE 24"0 RCP OUTLET BARREL AT A FREQUENCY OF ONE TEST PER 25 LF OF PIPE PER VERTICAL FOOT OF FILL OR AS DIRECTED BY THE ON-SITE GEOTECHNICAL ENGINEER. STATEMENT OF RESPONSIBILITY 1. ALL REQUIRED MAINTENANCE AND INSPECTIONS OF THE STORMWATER MANAGEMENT FACILITIES SHALL BE THE RESPONSIBILITY OF THE OWNER, PER THE EXECUTED OPERATION AND MAINTENANCE AGREEMENT FOR THIS FACILITY. CONSTRUCTION SEQUENCE 1. PRIOR TO CONSTRUCTION, THE OWNER SHALL OBTAIN A LAND DISTURBING (GRADING) PERMIT AND AN "APPROVAL TO CONSTRUCT" FROM THE TOWN OF TROUTMAN AND ALL OTHER NECESSARY PERMITS FROM APPLICABLE AGENCIES (E.G. 404 / 401 PERMITS) 2. INSTALL ALL SEDIMENT AND EROSION CONTROL MEASURES PER THE APPROVED SEDIMENT AND EROSION CONTROL PLAN. THE CONTRACTOR SHALL MAINTAIN ALL APPROVED SEDIMENT AND EROSION CONTROL MEASURES THROUGHOUT THE ENTIRE PROJECT, AS REQUIRED. THE CONTRACTOR SHALL RECEIVE APPROVAL FROM THE EROSION CONTROL INSPECTOR, AS REQUIRED BY GOVERNING AGENCIES, PRIOR TO ANY CLEARING. 3. CLEAR AND GRUB AREA WITHIN THE LIMITS OF THE PROPOSED DAM CONSTRUCTION. ALL TREES AND THEIR ENTIRE ROOT SYSTEMS MUST BE REMOVED FROM THE DAM FOOTPRINT AREA AND BACKFILLED WITH SUITABLE SOIL MATERIAL. THE BACKFILLED AREAS SHALL BE COMPACTED TO THE SAME STANDARDS AS THE DAM EMBANKMENT. THE REMAINING AREA OF THE EMBANKMENT SHALL BE STRIPPED TO A SUITABLE DEPTH AS DIRECTED BY THE ON-SITE GEOTECHNICAL ENGINEER. ANY RESIDUAL SOILS TO BE LEFT IN PLACE MUST BE WELL SCARIFIED TO PROMOTE BONDING OF THE NEW EMBANKMENT FILL. NO EMBANKMENT MATERIAL SHALL BE PLACED FOR THE DAM OR KEY TRENCH UNTIL APPROVAL OF THE DAM SUBGRADE / TRENCH IS OBTAINED FROM THE ON-SITE GEOTECHNICAL ENGINEER. 4. EXCAVATE FOR THE NEW KEY TRENCH ALONG THE CENTERLINE OF THE PROPOSED DAM EMBANKMENT. THE TRENCH SHALL EXTEND A MINIMUM OF 5 FT BELOW EXISTING GRADE OR 2 FT BELOW THE CONCRETE CRADLE AND SHALL HAVE A MINIMUM BOTTOM WIDTH OF 5 FEET. THE KEY TRENCH SIDESLOPES SHALL BE A MINIMUM OF 1:1 (H:V). THE KEY TRENCH SHALL BE COMPACTED TO THE SAME SPECIFICATION LISTED IN ITEM 4 OF THE SECTION TITLED "BERM AND SOIL COMPACTION SPECIFICATIONS." DEPENDING UPON ON-SITE SOIL CONDITIONS ENCOUNTERED DURING EXCAVATION, THE ON-SITE GEOTECHNICAL ENGINEER MAY VARY THE DEPTH AND DIMENSIONS OF THE KEY TRENCH AS DEEMED NECESSARY. THE ON-SITE GEOTECHNICAL ENGINEER SHALL RETAIN DOCUMENTATION OF ANY VARIATION FOR FUTURE AS -BUILT SUBMITTALS TO THE TOWN OF TROUTMAN. 5. BEGIN PLACEMENT OF BACKFILL WITHIN THE KEY TRENCH. THE KEY TRENCH SHALL BE COMPACTED TO THE SPECIFICATIONS LISTED ITEM 4 OF THE SECTION TITLED "BERM AND SOIL COMPACTION SPECIFICATIONS." THE KEY TRENCH SHALL BE TESTED PER THE SPECIFICATIONS LISTED IN THAT SECTION. 6. PRIOR TO INSTALLATION, SUBGRADE CONDITIONS ALONG THE SPILLWAY PIPES SHOULD BE EVALUATED BY THE ON-SITE GEOTECHNICAL ENGINEER TO ASSESS WHETHER SUITABLE BEARING CONDITIONS EXIST AT THE SUBGRADE LEVEL. SHOULD SOFT OR OTHERWISE UNSUITABLE CONDITIONS BE ENCOUNTERED ALONG THE PIPE ALIGNMENTS, THESE MATERIALS SHOULD BE UNDERCUT AS DIRECTED BY THE GEOTECHNICAL ENGINEER. THE UNDERCUT MATERIALS SHALL BE REPLACED WITH ADEQUATELY COMPACTED STRUCTURAL FILL, LEAN CONCRETE OR FLOWABLE FILL AS DIRECTED BY THE ON-SITE GEOTECHNICAL ENGINEER. 7. IN ORDER TO HELP PROTECT THE SOIL SUBGRADE FROM DETERIORATION (DUE TO EXPOSURE, RAINFALL, SEEPAGE, AND RUNOFF) BEFORE THE CRADLE CAN BE POURED, IT IS STRONGLY RECOMMENDED THAT A 3" TO 4" THICK CONCRETE MUD MAT BE POURED OVER THE SUBGRADE ONCE IT IS APPROVED BY THE ON-SITE GEOTECHNICAL ENGINEER. THE MUD MAT WILL ALSO PROVIDE BEARING FOR THE BLOCKS THAT TEMPORARILY SUPPORT THE SPILLWAY PIPE UNTIL THE CRADLE CAN BE POURED. THE METHOD OF BLOCK SUPPORT FOR THE PIPE PROPOSED BY THE CONTRACTOR SHOULD BE SUBMITTED TO THE JOHN R. McADAMS COMPANY FOR REVIEW. 8. BEGIN CONSTRUCTION OF THE NEW EMBANKMENT. FILL MATERIALS SHALL BE PLACED IN MAXIMUM 8" THICK LIFTS PRIOR TO COMPACTION, UNLESS DIRECTED OTHERWISE BY THE ON-SITE GEOTECHNICAL ENGINEER. FILL LIFTS SHALL BE CONTINUOUS OVER THE ENTIRE LENGTH OF FILL. IF IT IS NECESSARY, THE EMBANKMENT FILL MATERIAL WILL BE OVERBUILT IN HORIZONTAL LIFTS AND CUT BACK TO FINAL GRADE IN ORDER TO ACHIEVE PROPER COMPACTION. 9. AS CONSTRUCTION OF THE EMBANKMENT MOVES FORWARD, IT WILL BE NECESSARY TO INSTALL THE CONCRETE CRADLE. THIS MAY BE CONSTRUCTED USING ONE OF THE FOLLOWING METHODS: 9.1. IF THE PROPOSED STRUCTURAL FILL MATERIAL IS UTILIZED AS THE FORMWORK FOR THE CONCRETE CRADLE, THEN THE STRUCTURAL FILL SHOULD BE INSTALLED AND COMPACTED UP TO THE TOP OF CONCRETE CRADLE ELEVATION. ONCE THE STRUCTURAL FILL REACHES THE NEXT DOWNSTREAM JUNCTION BOX OR HEADWALL AND IS COMPACTED TO THE ELEVATION OF THE TOP OF THE CONCRETE CRADLE, EXCAVATE THE CONCRETE CRADLE TRENCH PER THE PROVIDED DETAILS AND CONSTRUCT THE CONCRETE CRADLE AS PER THE PROVIDED CONCRETE CRADLE DETAIL. 9.2. IF THE PROPOSED STRUCTURAL FILL IS NOT UTILIZED AS THE FORMWORK FOR THE CONCRETE CRADLE, THEN PRIOR TO CONSTRUCTING THE STRUCTURAL FILL EMBANKMENT, THE FORMWORK FOR THE CONCRETE CRADLE SHOULD BE INSTALLED ON EXISTING GROUND AND / OR THE MUD MAT. THE CONCRETE CRADLE SHALL BE CONSTRUCTED PER THE PROVIDED DETAILS. 10, INSTALL RISER / BARREL ASSEMBLY, ALONG WITH THE EMERGENCY DRAIN SYSTEM. THE DRAIN VALVE LOCATED WITHIN THE RISER BOX SHALL BE KEPT OPEN UNTIL AN AS -BUILT CERTIFICATION HAS BEEN COMPLETED BY THE ENGINEER AND AN APPROVAL TO IMPOUND HAS BEEN ISSUED BY ALL APPLICABLE AGENCIES. 11. INSTALL 24" RCP OUTLET BARREL SPILLWAY FILTER FROM THE DETAILS SHOWN ON SHEET SHEET SW -134. 12. CONSTRUCT EMBANKMENT PER SPECIFICATIONS LISTED IN THE SECTION TITLED "BERM AND SOIL COMPACTION SPECIFICATIONS" AND REQUIREMENTS OF THE ON-SITE GEOTECHNICAL ENGINEER. ALL CHARACTERISTICS OF THE EMBANKMENT FILL MATERIAL SHALL MEET THE STANDARDS SET FORTH IN "BERM AND SOIL COMPACTION SPECIFICATIONS", INCLUDING COMPACTION AND MOISTURE REQUIREMENTS. IF NECESSARY TO ACHIEVE PROPER COMPACTION, THE EMBANKMENT FILL MATERIAL WILL BE OVERBUILT IN HORIZONTAL LIFTS AND CUT BACK TO PROPER FINAL GRADE. ANY HAND COMPACTION ACTIVITIES AROUND SPILLWAY OR DRAIN STRUCTURES SHALL BE CONDUCTED IN 4 -INCH LOOSE LIFTS AND BE TO THE SAME COMPACTION AND MOISTURE REQUIREMENTS AS THE ENTIRE EMBANKMENT. ALL COMPACTION AND MOISTURE TESTING SHALL BE CARRIED OUT AS DIRECTED BY THE ON-SITE GEOTECHNICAL ENGINEER AND AS LISTED IN THE SECTION TITLED "BERM AND SOIL COMPACTION SPECIFICATIONS". 13. UPON COMPLETION OF DAM EMBANKMENT, PROMPTLY STABILIZE AND SEED DAM EMBANKMENT PER SEEDING SCHEDULE. 14. SCHEDULE A FINAL AS -BUILT INSPECTION AND AS -BUILT SURVEY WITH THE ENGINEER. AN AS -BUILT INSPECTION SHOULD BE SCHEDULED A MINIMUM OF 60 DAYS BEFORE A PERMIT TO IMPOUND IS REQUIRED. ANY COMMENTS OR DEFICIENCIES IN THE DAM CONSTRUCTION MUST BE CORRECTED TO THE SATISFACTION OF THE ENGINEER AND OWNER BEFORE CERTIFICATION SHALL BE GRANTED. UPON FINAL APPROVAL FROM THE TOWN OF TROUTMAN, CLOSE THE 8"0 BOTTOM DRAIN VALVE IN THE RISER BOX AND BEGIN IMPOUNDING WATER. NO WATER SHALL BE IMPOUNDED BEFORE AN APPROVAL TO IMPOUND IS ISSUED FROM THE TOWN OF TROUTMAN. OUTLET STRUCTURE MATERIAL SPECIFICATIONS 1. THE 24"0 RCP OUTLET BARREL SHALL BE CLASS III RCP, MODIFIED BELL AND SPIGOT, MEETING THE REQUIREMENTS OF ASTM C76 -LATEST. THE PIPES SHALL HAVE CONFINED O-RING RUBBER GASKETJOINTS MEETING ASTM C -443 -LATEST. THE PIPE JOINTS SHALL BE TYPE R-4. 2. THE STRUCTURAL DESIGN FOR THE 4'X 4' (INTERNAL DIMENSIONS) RISER BOX WITH EXTENDED BASE SHALL BE BY OTHERS. PRIOR TO ORDERING THE STRUCTURES, THE CONTRACTOR SHALL PROVIDE, TO THE DESIGN ENGINEER FOR REVIEW, SHOP DRAWINGS AND SUPPORTING STRUCTURAL CALCULATIONS SEALED BY A P.E. REGISTERED IN NORTH CAROLINA DEMONSTRATING THE PERTINENT VERTICAL LOADS ARE SUPPORTED BY THE CONCRETE RISER STRUCTURE. 3. THE RISER BOX OUTLET STRUCTURE SHALL BE PROVIDED WITH STEPS 16" ON CENTER. STEPS SHALL BE PROVIDED ON THE INNER WALL OF THE RISER BOX. STEPS SHALL BE IN ACCORDANCE WITH NCDOT STD. 840.66. PLEASE REFER TO SHEET SW -B2 FOR LOCATION OF THE RISER STEPS. 4. THE CONCRETE ANTI -FLOTATION BLOCKS SHALL BE PRECAST AS THE EXTENDED BASE OF THE RISER BOX DURING FABRICATION. THE PRECAST BASE SHALL BE INCLUDED AS PART OF THE SHOP DRAWINGS THAT WILL BE SUBMITTED TO THE ENGINEER FOR REVIEW (SEE ITEM 2 ABOVE). IN LIEU OF A PRE -CAST BASE, THE CONTRACTOR MAY OPT TO CAST -IN-PLACE THE ANTI -FLOTATION BLOCK IN THE FIELD. HOWEVER, PRIOR TO CONSTRUCTING THE CAST -IN-PLACE BASE, THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE ENGINEER FOR REVIEW DENOTING THE FOLLOWING: A. STEEL REINFORCEMENT B. THE CONNECTION MECHANISM TO JOIN THE ANTI -FLOTATION BLOCK WITH THE RISER SECTION 5. IF THE ANTI -FLOTATION BLOCK IS PRECAST AS PART OF THE RISER BASE SECTION, THE ENTIRE PRECAST RISER BOX STRUCTURE SHALL HAVE A SHIPPING WEIGHT OF 28,547 LBS. THE STRUCTURE WEIGHT SHALL BE THE SHIPPING WEIGHT AND SHALL BE DETERMINED BY SUBTRACTING THE WEIGHT OF THE FACTORY BLOCK OUTS FROM THE GROSS STRUCTURE WEIGHT. THIS INFORMATION SHALL BE SHOWN ON THE SHOP DRAWINGS SUBMITTED TO THE ENGINEER FOR REVIEW. IF THE CONTRACTOR OPTS TO CAST -IN-PLACE THE ANTI -FLOTATION BLOCK, THE CONTRACTOR SHALL ENSURE THE WEIGHT OF THE ENTIRE RISER STRUCTURE IS EQUAL TO THE MINIMUM LISTED ABOVE, 6. THE RISER BOX JOINTS SHALL BE SEALED USING BUTYL RUBBER SEALANT CONFORMING TO ASTM -C990 -LATEST. IF NECESSARY, THE CONTRACTOR SHALL INCORPORATE A WATERSTOP INTO THE RISER BOX JOINT TO ENSURE A WATERTIGHT CONNECTION. THE CONTRACTOR SHALL PARGE JOINTS ON BOTH THE INSIDE AND OUTSIDE WITH NON -SHRINK GROUT. 7. PRIOR TO ORDERING, THE CONTRACTOR SHALL SUBMIT TRASH RACK SHOP DRAWINGS TO THE ENGINEER FOR REVIEW. CONTRACTOR SHALL ENSURE THAT AN ACCESS HATCH IS PROVIDED WITHIN THE TRASH RACK (SEE DETAIL FOR LOCATION) THAT WILL ALLOW FOR FUTURE MAINTENANCE ACCESS. CONTRACTOR SHALL ALSO PROVIDE A CHAIN AND LOCK FOR SECURING THE ACCESS HATCH. NOTE THE ACCESS HATCH SHALL LINE UP WITH THE ACCESS STEPS AFTER INSTALLATION. 8. ALL POURED CONCRETE SHALL MEET THE FOLLOWING SPECIFICATIONS UNLESS OTHERWISE NOTED: -MINIMUM 3000 PSI (28 DAY) -SLUMP = 3" - 5" -ENTRAINED AIR = 5%- 7% PLEASE NOTE NO CONCRETE SHALL BE POURED WHEN THE AMBIENT AIR TEMPERATURES ARE EXPECTED TO BE ABOVE 85'F OR BELOW 40°F. CAST -IN-PLACE CONCRETE SHALL BE "WET CURED" AFTER FINISHING FOR A MINIMUM OF 48 HOURS. 9. GEOTEXTILE FABRIC FOR THE 24"0 RCP OUTLET BARREL JOINTS SHALL BE MIRAFI 18ON OR ENGINEER APPROVED EQUAL (NON -WOVEN FABRIC) 10. STORMWATER FACILITY EMERGENCY DRAW DOWN IS VIA AN 8"0 PLUG VALVE. THE VALVE SHALL BE A M&H STYLE 1820 X -CENTRIC VALVE OR APPROVED EQUAL. THIS VALVE IS IN ACCORDANCE WITH AWWA C-517, AND SHALL BE OPERABLE FROM TOP OF OUTLET STRUCTURE VIA A HAND WHEEL (SEE DETAIL SHEET SW -63). THE CONTRACTOR SHALL PROVIDE A REMOVABLE VALVE WRENCH WITH A HAND WHEEL ON TOP FOR OPERATION OF THE 8"0 PLUG VALVE. A CHAIN AND LOCK SHALL ALSO BE PROVIDED FOR SECURING THE WRENCH TO THE TRASH RACK. TW=1 71.75 LL_j_'848.00 II I I I I I I I 868. 5 / W=84.0 TW 71. B 048. 5 // /_- N E=841 00 T- / PRECAST RISER OUTLET STRUCTURESHAPE = SQUARE / 3. / // / I I / INTERNAL DIMENSIONS = 4 FT. x 4 FT. / \ SLOpE l l 3� I / I TOP OF RISER = 845.00 Stop I I I I / 1.0"0 ORIFICE = 842.00 00 q ry /^ E / / 1 I I I / 2.25"0 ORIFICE (INVERTED SIPHON) = 841.00 / d o / \ INVERT OUT (24"0 O-RING RCP) 836.00CO \ (SEE DETAIL ON SHEET SW -B2) \ �/CO / / 74 LF 24"0 CLASS III MAIN POOL I I / / I O-RING RCP ® 2.70% W/ CONCRETE CRADLE \ \ (JOINTS WRAPPED IN \ I I \ J I GEOTEXTILE FABRIC) ENDWALL PER II I NCDOT STD. 838.80 INV. OUT (24"0 RCP) = 834.00 I CONTRACTOR SHALL LINE OUTLET Q/ / // / / / / / / / / CHANNEL WITH NCDOT CLASS 'B' RIPRAP. i i /' // // v / v� / / I / / THERE SHALL BE NO DISTURBANCE TO I / i / / / / / // / // ANY EXISTING CHANNEL BANk. A FILTER BLANKET SHOULD BE INSTALLED BETWEEN RIPRAP & SOIL FOUNDATION. FILTER VELOCITY DISSIPATOR / BLANKET SHALL CONSIST OF A MINIMUM NCDOT CLASS B RIPRAP - / / / � � � " � / / / I 4" THICK LAYER OF NCDOT #57 STONE � 12 L X 6 W X 22 THICK UNDERDRAIN WITH MIRAFI FILTER WEAVE / 1 / / / / /o / / / D50 = 8" I / I 700 OR APPROVED EQUIVALENT. (SEE DETAIL SHEET SW -B4)00 / =870.00 6 -FT AQUATIC SHELF I / // / /BW=847.00 i / / / ( 3' /4� �6 of FROM EL. 840.50 TO 841.50 I / S4 pp Cb o ® 6:1 SLOPE (TO BE INSTALLED I / �a * > AROUND SWMF PERIMETER) RETAINING WALL / / / 4 7 (TYP.) (DESIGN I T � BY OTHERS) \ CO/ / / / / � /TOP OF BANK (EYP.) \ i I � / �/ STORMWATER CONTROL MEASURE MAINTENANCE ACCESS EASEMENT / v8�0/ I l l / A 8A7 AjOQ / 40' TEMPORARY SEWER EASEMENT 77� / / / - \/ / INV = 841.00 / / I OQ / \ / / / �� \ / \ / SEWER EASEMENT \ I SEDIMENT FOREBAY T ,\ 1 / I V EBAY wEIR FOR PI LWAY s L / CREST = 9 LF =8 7.0 / / / / / / / ' TOP F RIP RAP T LINERNCDOT CLASS B" RIPRAP 15" MIN. DEPTH (D50 = 8") NOTE: A FILTER BLANKET IS TO BE INSTALLED BETWEEN THE RIP RAP AND SOIL FOUNDATION. THE FILTER BLANKET WILL CONSIST OF A MINIMUM 4" THICK LAYER OF / I 6 / / I STONE (#57) UNDERLAIN WITH MIRAFI FILTER WEAVE 700 OR APPROVED EQUIVALENT / \ 38 � 42 FOREBAY BERM EL. = 841\00 l 844 / / / / / / / / / // MINIMUM WIDTH = 5 FT TO BE COMPACTED 4 / / / / / / /`� /PER "BERM AND SOIL 8COMPACTION SPECIFICATIONS' 4 \ � 850 100' STREAM BUFFER (TYP.) -� � �\ � / / I / / / / / /' / / \ Ap I 10' ASPHALT GREENWAY GRAPHIC SCALE 0 10 20 40 /� -- - 1 inch = 20 ft. STORMWATER CONTROL MEASURE W PLAN VIEW 1" = 20' FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER (vI�I V � z�00 O UDC) CHECKED BY JAA W ?:wN LU 1" = 20' 0z Q DC z J (� Z �C zLU U 0 0 0 = O UDC) CHECKED BY JAA cc Z) SCALE 1" = 20' 0z W SHEET Z W 0 O F_ U -A.'-\A CARO '�.. ESS/0• '•� SEAL 1 33782 % S 4 •'/VG I NE�•�pQ REVISIONS N0. DATE PLAN INFORMATION PROJECT NO. RYN-17010 FILENAME RYN17010-SWB CHECKED BY JAA DRAWN BY JSM SCALE 1" = 20' DATE 11. 26. 2018 SHEET STORMWATER CONTROL MEASURE'S' PLAN VIEW SW -B1 APPROXIMATE LOCATION OF NOTES: � EXISTING GROUND \ 1. REMOVED TOPSOIL SHALL BE STOCKPILED FOR USE IN PLANTING (SEEDING) THE DAM EMBANKMENT ONCE FINAL GRADES (AS SHOWN ON THE GRADING PLAN) HAVE BEEN ESTABLISHED WITH COMPACTED \ COMPACTED BERM SECTION FILL. PRIOR TO TOPSOIL INSTALLATION, THE CONTRACTOR SHALL SCARIFY THE TOP 2- TO 3 -INCHES OF 10 FT. WIDE MINIMUM THE BERMN SECTION TO PROMOTE BONDING OF THE TOPSOIL WITH THE COMPACTED FILL. THE TOP OF HANDWHEEL TO EXTEND (SEE BERM AND SOIL COMPACTION TOPSOIL DEPTH SHALL RANG FROM 3- TO 4 -INCHES ON THE DAM EMBANKMENT. TOP OF DAM EL. = 847.00 1 -FOOT ABOVE TRASH RACK - - - - - - � SPECIFICATIONS ON SHEET SW -B1 PROPOSED GRADE _ -_ - - - 100 -YEAR STORM EL. = 845.63 TRASH RACK _- I=III=1 i t=1 I I=1 I=I I I=I 11=I I I=i I I=I I I=1 I M I Il' TrT 10 -YEAR STORM EL = 845.04 (SEE DETAIL) I=III=III-� I=III= III=I 1=III=III=III I I I II I II 11I I IIIA 11h1 i� VELOCITY DISSIPATOR TOP OF RISER EL. = 845.00 _ I=I I I=I I I=I I I=I I I=1 I I=1 I I=1 I=I I I=1 I IE 1 I I=1 I I=1 I=_=_= ____-�, NCDOT CLAS 'B' RIPRAP 1.0"0 ORIFICE _ _ INV. = 842.00 =1 I I=III=1 I I=1 I =1 I I=III=III=III I I=1 I I=1 I I=III=1 I I=1 I I=1 I ={ I I=III-III-III-I MINIMUM DIMENSIONS 2 -YEAR STORM EL. = 843.62 INW. (SEE DETAIL SHEET SW -B4) 3 _ 3 12'L X 6'W 22" THICK _- I I I=1 I I=III=I I I=I I I=I I I=111=III=III=1 1=III=III=III=III=III=III=III=III-{II-III-III-III I� D50 = 6" SIPHON W/ 2.2!5"0 DRILLED ORIFICE 1 �- _ _ _ -� 1 INV. = 841.00 = 1=III=III I I=III=1 I I=III=III=III=III=III=III III=III=III=III=III=III=III=III=� i -II{ -III -Ili �-III=m= TO BE LINED WITH GEOTEXTILE (SEE DETAIL SHEET SW -B3) _- I=III=III=III=III I I=1 I I=I I I=I I I=I 11=I I I=1 I I=III=1 I=I I I=I 11=1 I I=II1=1 I I=I 11=1 I I=I 11=I I I=I 11=1II 1=1 I I=I I I=I I I� I FABRIC OR EQUIVALENT WQV STORM EL. = 841.98 CONCRETE col_u�R = 1=III=III=III=III=III=III I I=III=III=II1=1 I Ed I I=1II=III III III=III=1II=1I1=1 I I=III=1 I I=II=III=III �=III=I I I=I I I=III=1�1�,, (SEE DETAIL SH ET SW -B4) NORMAL WATER SURFACE EL. (IvwsE) = 841.00 0 (To BE CONSTRUCTED IN _-_= 1=III=III=III=III=III=III=III=III I I=1 I I=III=1 I I=III=III-II15.0j (MIN) I I -I I I -I I I -I I I -I I I -I I I -III -III -III -III k -III -III -III -III -III -I I I_� (1� THE FIELD BY THE _ = I I=III=III=III=III=III=III=III=III =III=III = I I=III=III=III=III=III=I i I I I=III=1 I I=1 I I=III=III=III=III=III=III = III=III=Ili=III=III=III=III=III �R ►� ENDWALL PER NCDOTSTD. 838.80 CONTRACTOR, SE DETAIL) (SEE DETAIL ON HEET SW -B3) 111=1 I I=1 11=1 I I=1 11=1 I I=111=III=1 11=1 11=1 11=1 I I=1 11=1 11=i I I 11=1 11=1 11=1 11=1 11=1 11=1 1=1 11=1 11=1 I I=1 11=1 I i=1 11=1 11=1 11=1 I I- 1= 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=mom - =1 11=1 11=1 11=1 11=1 I I=I 11=I 11=1 11=1 11=1 11=1 11=I I I-1 11=1 11=1 11-I 11=1 I I i 1=1 I I -I 11=1 11=1 11=1 I I I i 1=1 11=1 11=1 I I -I 11=1 11=1 11=1 I I -III I_I 11=1 11=1 I I-{ 11=1 I I_I 11=1 11=1 I I -I 11=1 I I -III -I I I� "--- -_ __-__ =1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 I I 11=1 11=1 11=1 11=1 11=1 1=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 I I- 1=1 11=1 11=1 11=1 I I=1 11=1 I I_I I -III -I I i=1 I I -I 11=1 I I -I 11=1 ITS_ 12 COVER (MIN.) _ -III-III-III-III-III-III-III 111 = -- 1�11_L_ _- I I-III-III-III-III=III=III-III-� I=III=III=III=III=III=III I I=III=III=III=III III=III=I I I=1 I I=III=III=III=III- �=III=III=III=III=III=111=III=1 I I=1 I I=III=III=III=1 I I=1 I I=III=1 Ili -- I =1 1=III=1 I {=III=I I i=1 I I=I 11=III- �=III-I 11-I 11-I 1 I -III -1 { 1-1 11-I I I-1 I I -I I I -I I I -I I I=I I I=III=1 11=III=III= I-= _ -- ------ --------------- (------>------------------------_--__ = = = _ - _ _ - -11=III=III=III=III=III=III=III=III=III=1 III o FLOW -- 74 LF CLASS III 24"0 0 -RING RCP ASTM C76 -LATEST ®2.70 - - - - - - - d- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - O 24"0 RCP INV. OUT EL. = 836.00 ° . ' ' d 4 ° ° d d d ----a = -- ---d - --=� ° -- �------�4=-----'-d-------- �_°d o 0 0 0 / \ \ \ \ \ \ \ \ \ \ \ \ \7-\777-7---- //\// \ \ \ 24"0 CLASS III 0 -RING RCP\//\//\//\//\//\//\//\//\//\//\//\//\//\//\//\/// 2.0' (MIN °. ° d 4 0 0 0 \/ /\ \ \\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\ I III \ \ \ \ \ \ \ \ \ \ \ \ \INV. 836.00 \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\/\\/\\/\\/\\/\\/\\ /\\/\ d/ / \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \ 1 THICK PpINT \\ \\ \\ \\ \\ \\ \\ \ \ \ \ \ \ \ \ \ \ \ \ \ \\ \\ \\ \\ \\\/\//\ 'i / // // // // // // // // // // / // // // // // // // // // / „ CONCRETE i�/ / / / / / / / / / ,/ ,/ ,/ ,/ // // // // // // // // // // // // // // // // // // // // // /\/\/\/\/\/\/\/\//\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\ /\/\/\/\/\/\/\/\/\ \ \\ \\ \\ \\ \\ \ \\ \\ \\ \\ \\ \\ \\ \\ \ \\ \\ \\ \\ \ 24 CLASS III - CK\�\\�\/\\�\\�\\�\\,\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ \ \ \ \ \ \ \ \ \ \ \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\�\//�\//�//�//�/\/\/\ \/\/\/\/\/ /\/\/\/\ \/\/\/\/\/O-RING RCP ANTI FLOTATION BLOCK \ \ \ �\ i\ /� /� /�//� //\ //%//\//\//\//\//\//\//\//\//\/i�/i�/i�/i�/i�/i�/i�/i�/i�/i�/i�/i�//\ / \\\\// // // // // // // // // // // // // // \\\i\\\ \\ \\ \\ \\i\\i\\ TRENCH (SEE BERM AND SOIL COMPACTION\\\\\\\\\\\\\\\\�\\\\�\\\\\\\\\\\\\\\\�\\/\ GEOE DOUBLE ILE LAYER OF ° SHALL BE PLACED /� i 0 CRETE CRADLE /\\/\\/\\ \ \ \ \ \\ INVERT EL. = 834.00 8"0 EMERGENCY DIP DRAIN CONTRACTOR SHALL FORM INVERT OF SPECIFICATIONS, DETAIL SHEET SW -B1) " SPILLWAY FILTER WITH TRASH RACK RISER STRUCTURE: TO DRAIN POSITIVELY AROUND EACH JOINT OF EACH 24"0 O-RING RCP (SEE DETAIL ON SHEET SW -B4) (SEE DETAIL SHEET SW -B3) TO INVERT OF OUTLET BARREL USING KEY TRENCH TO BE PROVIDED PER THE SEE DETAIL NON -SHRINK GROUT DIRECTION OF THE SITE GEOTECHNICAL ENGINEER PERMANENT DAM CROSS SECTION BARREL IN 2' WIDE STRIPS CENTERED ON JOINT. ( N.T.S. SHEET SW -B4) J"0 GRADE 8 STAINLESS STEEL ° CONCRETE LAG SCREW 0 12" X 4" X J" GALVANIZED STEEL ° STRAP (4 PER RISER JOINT) 3.0" RISER JOINT CONNECTION DETAIL N.T.S. NOTES: 1. CONCRETE ANTI -FLOTATION BLOCK TO BE PROVIDED WITH MINIMUM TEMPERATURE AND SHRINKAGE STEEL REINFORCEMENT. 2. TRASH RACKS NOT SHOWN FOR CLARITY. 3. THE NUMBER OF GUIDES FOR THE VALVE STEM SHALL BE DETERMINED IN THE FIELD BY THE CONTRACTOR. THE VALVE STEM MUST BE OPERABLE FROM THE TOP OF THE RISER VIA THE HANDWHEEL WITH AN INSIGNIFICANT AMOUNT OF PLAY IN THE VALVE STEM. 4. CONTRACTOR SHALL PROVIDE A JOINT IN THE OUTLET BARREL NO MORE THAN 5 -FT FROM THE RISER. 1.0"0 OR INV. = 84 SIPHON W/ 2.25"0 DRILLED OR INV. = 84 (SEE DETAIL SHEET SW. i i I 8 DIP DRAIN W/ TRASH RACK " (SEE DETAIL SHEET SW -B3, i 3 0 23" s CONCRETE ANTI -FLOTATION I i CONTRACTOR SHALL FORM Iry vL ix..o S RISER STRUCTURE TO DRAIN POSITIVELY TO INVERT OF OUTLET BARREL USING NON -SHRINK GROUT L s L .00 8.00' PRECASTER SHALL PROVIDE A BLOCK OUT FOR THE 24"0 0 -RING RCP dm ° CONCRETE COLLAR ° . d d (TO BE CONSTRUCTED IN THE 1.50' 1.50' 01- ° 5.00' 4 - 1.5 d FIELD BY THE CONTRACTOR - SEE DETAIL) ° °4 ° ° d 8" DIP DRAIN W/ TRASH RACK ° ° 4 -•� -= CONCRETE CRADLE ° (SEE DETAIL SHEET SW -B3) d d ° ? ° d (SEE DETAIL ON ° SHEET SW -B4) ❑ d- - - - - - - - - 4° 8.00' 5.00' d d 24"0 0 -RING RCP 4" FLOW SIPHON W/ 2.25"0 DRILLED ORIFICE 7� d ° ' INV. = 841.00 -------- (SEE DETAIL SHEET SW -B3) a ° d 4 1.0"0 ORIFICE ° INV. = 842.00 d . d ° ° ° d v 1.50' d 4 a ° ° ° d ° d d a d 1" THICK JOINT FILLER MATERIAL ° . d (TYP.) ° 4 8"0 PLUG VALVE. THE VALVE SHALL BE A M&H STYLE 820 X -CENTRIC VALVE OR APPROVED EQUAL. THIS VALVE SHALL BE IN ACCORDANCE WITH AWWA C-504 SEC. 5.5, AND SHALL BE OPERABLE FROM TOP OF OUTLET STRUCTURE VIA A HANDWHEEL. CONTRACTOR SHALL PROVIDE STEPS IN ACCORDANCE WITH NCDOT STD. 840.66. TOP OF HANDWHEEL TO EXTEND STEPS SHALL BE PLACED AT 16" O.C. 1 -FOOT ABOVE TRASH RACK (SEE DETAIL ON SHEET SW -B3) rnKiTonrTOR SHALL PROVIDE STEPS IN NCE WITH NICDOT STD. 840.66. ALL BE PLACED AT 16" O.C. 41L ON SHEET SW -B3) TOP OF RISER EL. = 845.00 VALVE STEM GUIDE (SEE NOTE #3) 1.0"0 ORIFICE INV. = 842.00 11.42' SIPHON W/ 2.25"0 DRILLED ORIFICE INV. = 841.00 (SEE DETAIL SHEET SW -B3) 8" DIP DRAIN W/ TRASH RACK -� (SEE DETAIL SHEET SW -B3) INVERT OUT EL. = 836.00 C 4 ° d CONTRACTOR SHALL PROVIDE STEPS IN ACCORDANCE WITH NCDOT STD. 840.66. STEPS SHALL BE PLACED AT 16" O.C. (SEE DETAIL ON SHEET SW -B3) O d ° NOTES: a o d ° ANGLES TO BE HOT -DIPPED GALVANIZED AND BE PROVIDED WITH AN EPO ° 3. THE HOT -DIPPED, GALVANIZED 2"x2"x1/4" ANGLES SHALL BE WELDED TO THE d. 0 ONTO THE RISE 4 O• ANCHOR THE TRASH RACK TO MANHOLE WALL WITH FOUR 4"x1/4" CONCRETE ANCHOR BOLTS THROUGH ANGLES. 5. CONTRACTOR d 0.50' 4 . 14 ° d d ° d ° a 1.92' ° ° 4. . CONCRETE ANTI -FLOTATION BLOCK CONTRACTOR SHALL FORM INVERT OF RISER STRUCTURE TO DRAIN POSITIVELY TO INVERT OF OUTLET BARREL USING NON -SHRINK GROUT PERMANENT OUTLET STRUCTURE DETAILS PRECASTER SHALL PROVIDE A BLOCK OUT FOR THE 24"0 0 -RING RCP CONCRETE COLLAR (TO BE CONSTRUCTED IN THE FIELD BY THE CONTRACTOR - SEE DETAIL) 24"0 0 -RING RCP FLOW N.T.S. CONCRETE CRADLE (SEE DETAIL ON SHEET SW -B4) to THICK JOINT FILLER MATERIAL 7.0' 5.0' 3.0' ❑ 7.0' ' (TYP.) 9.9 LF 2"x2"x1/4" ANGLE THE BOLD / DASHED LINETYPE DENOTES THE ACCESS HATCH TO BE PROVIDED BY THE TRASH RACK FABRICATOR PER OUTLET STRUCTURE MATERIAL SPECIFICATIONS (SHEET SW -B1) NOTES: 1. ALL REBAR TO BE #4 REBAR. 3" CLEARANCE TO OUTSIDE OF #4 REBAR) 5.0' CONCRETE ANCHOR (TYP., SEE NOTE # 9.9 LF 2"x2"x1/4" ANGLE 2.0' �- CONCRETE ANCHOR BOLT (TYP., SEE NOTE #4) FABRICATED HINGES FOR THE 2'x3' ACCESS HATCH. ACCESS HATCH SHALL BE POSITIONED OVER STEPS. 9.9 LF 2"x2"x1/4" ANGLE RISER TRASH RACK DETAIL N.T.S. 3" CLEARANCE TO OUTSIDE OF #4 REBAR) RYN-17010 NOTES: RYN17010-SWB 1. ALL REBAR TO BE #4 REBAR. ° ANGLES TO BE HOT -DIPPED GALVANIZED AND BE PROVIDED WITH AN EPO COATING. 3. THE HOT -DIPPED, GALVANIZED 2"x2"x1/4" ANGLES SHALL BE WELDED TO THE REBAR TRASH RACK. ONCE WELDED, THE ENTIRE ASSEMBLY SHALL BE PLACED ONTO THE RISE WITH ANGLES SITTING DIRECTLY ON TOP OF RISER. 4. CONTRACTOR SHALL ANCHOR THE TRASH RACK TO MANHOLE WALL WITH FOUR 4"x1/4" CONCRETE ANCHOR BOLTS THROUGH ANGLES. 5. CONTRACTOR HALL OMIT OR ADJUST REBAR AS NECESSARY TO ALLOW FOR CONCRETE CO AR. 6. ACCESS HATCH SHALL ALIGN WITH STEPS IN RISER. d J 0 N.T.S. CONCRETE CRADLE (SEE DETAIL ON SHEET SW -B4) to THICK JOINT FILLER MATERIAL 7.0' 5.0' 3.0' ❑ 7.0' ' (TYP.) 9.9 LF 2"x2"x1/4" ANGLE THE BOLD / DASHED LINETYPE DENOTES THE ACCESS HATCH TO BE PROVIDED BY THE TRASH RACK FABRICATOR PER OUTLET STRUCTURE MATERIAL SPECIFICATIONS (SHEET SW -B1) NOTES: 1. ALL REBAR TO BE #4 REBAR. 3" CLEARANCE TO OUTSIDE OF #4 REBAR) 5.0' CONCRETE ANCHOR (TYP., SEE NOTE # 9.9 LF 2"x2"x1/4" ANGLE 2.0' �- CONCRETE ANCHOR BOLT (TYP., SEE NOTE #4) FABRICATED HINGES FOR THE 2'x3' ACCESS HATCH. ACCESS HATCH SHALL BE POSITIONED OVER STEPS. 9.9 LF 2"x2"x1/4" ANGLE RISER TRASH RACK DETAIL N.T.S. 3" CLEARANCE TO OUTSIDE OF #4 REBAR) 3" ANCHOR DEPTH 3" CLEARANCE TO OUTSIDE OF PRECAST #4 REBAR) STRUCTURE WALL d A d ° ° ° d / 3.625' / \ 24" O-RING ` 3.83' RCP I � - i 0.5' ANCHOR DEPTH RYN-17010 NOTES: RYN17010-SWB 1. ALL REBAR TO BE #4 REBAR. 2. ALL REBAR AND ANGLES TO BE HOT -DIPPED GALVANIZED AND BE PROVIDED WITH AN EPO COATING. 3. THE HOT -DIPPED, GALVANIZED 2"x2"x1/4" ANGLES SHALL BE WELDED TO THE REBAR TRASH RACK. ONCE WELDED, THE ENTIRE ASSEMBLY SHALL BE PLACED ONTO THE RISE WITH ANGLES SITTING DIRECTLY ON TOP OF RISER. 4. CONTRACTOR SHALL ANCHOR THE TRASH RACK TO MANHOLE WALL WITH FOUR 4"x1/4" CONCRETE ANCHOR BOLTS THROUGH ANGLES. 5. CONTRACTOR HALL OMIT OR ADJUST REBAR AS NECESSARY TO ALLOW FOR CONCRETE CO AR. 6. ACCESS HATCH SHALL ALIGN WITH STEPS IN RISER. 3" ANCHOR DEPTH 3" CLEARANCE TO OUTSIDE OF PRECAST #4 REBAR) STRUCTURE WALL d A d ° ° ° d / 3.625' / \ 24" O-RING ` 3.83' RCP I � - i 0.5' ANCHOR DEPTH 4" 3.8' 4on " (CENTER TO (CENTER TO (CENTER TO CENTER) CENTER) CENTER) FRONT VIEW CONCRETE ANTI -FLOTATION BLOCK #4 REBAR ANCHORS. - CONTRACTOR SHALL DRILL INTO PRECAST STRUCTURE WALL AND SET ANCHORS USING EPDXY GROUT 3" CLEARANCE TO OUTSIDE OF #4 REBAR) CONCRETE COLLAR DETAIL N.T.S. d 1' DEPTH 3000 PSI CONCRETE COLLAR (MIN. 28 DAY STRENGTH) 3" CLEARANCE TO OUTSIDE OF #4 REBAR) ° 24" 0 -RING RCP .4 ° 6" AN DEPTH d 5.5" CENTER TO CENTER �- #4 REBAR ANCHORS. CONTRACTOR SHALL DRILL INTO PRECAST BASE AND SET ANCHORS USING EPDXY GROUT SIDE VIEW CONCRETE ANTI -FLOTATION BLOCK FINAL DRAWING -NOT RELEASED FOR CONSTRUCTION J ,f } The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER RYN-17010 FILENAME RYN17010-SWB CHECKED BY d. DRAWN BY � SCALE Z �. 00 9 "' a W ° W Q Q cro z Q d J 0 Zwa d d 0 4" 3.8' 4on " (CENTER TO (CENTER TO (CENTER TO CENTER) CENTER) CENTER) FRONT VIEW CONCRETE ANTI -FLOTATION BLOCK #4 REBAR ANCHORS. - CONTRACTOR SHALL DRILL INTO PRECAST STRUCTURE WALL AND SET ANCHORS USING EPDXY GROUT 3" CLEARANCE TO OUTSIDE OF #4 REBAR) CONCRETE COLLAR DETAIL N.T.S. d 1' DEPTH 3000 PSI CONCRETE COLLAR (MIN. 28 DAY STRENGTH) 3" CLEARANCE TO OUTSIDE OF #4 REBAR) ° 24" 0 -RING RCP .4 ° 6" AN DEPTH d 5.5" CENTER TO CENTER �- #4 REBAR ANCHORS. CONTRACTOR SHALL DRILL INTO PRECAST BASE AND SET ANCHORS USING EPDXY GROUT SIDE VIEW CONCRETE ANTI -FLOTATION BLOCK FINAL DRAWING -NOT RELEASED FOR CONSTRUCTION J ,f } The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER lq�' \A CAR04 y: SEAL At A•pIV"t,•`I-2�-v� REVISIONS N0. DATE PLAN INFORMATION PROJECT NO. RYN-17010 FILENAME RYN17010-SWB CHECKED BY fV) V DRAWN BY � SCALE Z �. 00 SHEET "' N W 5 W Q Q cro z Q J 0 Zwa U 00 0 U 0 z Uj (V/ 1•'j z V) i ^ D z W 0 0 U lq�' \A CAR04 y: SEAL At A•pIV"t,•`I-2�-v� REVISIONS N0. DATE PLAN INFORMATION PROJECT NO. RYN-17010 FILENAME RYN17010-SWB CHECKED BY JAA DRAWN BY JSM SCALE N.T.S. DATE 11.26. 2018 SHEET STORMWATER CONTROL MEASURE 'B' DETAILS #6 REBAR CONTRACTOR! SHALL CORE -DRILL PERIMETER FRAME THE HOLE FOR THE 8"0 DIP IN THE FIELD. PRECASER SHALL OMIT REINFORCEMENT IN THIS ° AREA 4" x 4" 6/6 WELDED WIRE 4" x 4" 6/6 WELDED WIRE FABRIC (EACH SIDE & TOP OF FABRIC (EACH SIDE &TOP OF ° 6" MIN. WALL 8" PLUG VALVE. THE VALVE CAGE) ° CAGE) THICKNESS SHALL BE A M&H STYLE 1820 X -CENTRIC VALVE OR 4.. APPROVED EQUAL. THIS VALVE CONTRACTOR SHALL SEAL THE PIPE SHALL BE IN ACCORDANCE a ° PENETRATION USING A RUBBER BOOT WITH AWWA C-517, AND 18" (TYP.) AND STAINLESS STEEL HARDWARE A SHALL BE OPERABLE FROM TOP OF OUTLET STRUCTURE VIA A HANDWHEEL. 2.03' 2 LF O a o 2.00' 8"0 DIP O N° 4 a ❑ O O 18" (TYP.) ° ° `8" PLUG VALVE. THE VALVE ° d 2 LF 8"0 DIP ° SHALL BEAM&H STYLE 1820 X -CENTRIC VALVE OR ° 4 ENGINEER APPROVED EQUAL. ° THIS VALVE SHALL BE IN 4" ANCHOR DEPTH ° ° CONTRACTOR SHALL SEAL THE PIPE IL CONTRACTOR SHALL 4. ° ACCORDANCE WITH AWWA d 4 ° C-517, AND SHALL BE AND ESTAINLESS USING EEL HARDWARE OOT DRILL INTO PRECAST ° d ° OPERABLE FROM TOP OF EXTENDED BASE AND OUTLET STRUCTURE VIA A ° SET ANCHORS USING HANDWHEEL. EPDXY GROUT 0.86' #6 REBAR PERIMETER FRAME (CENTER TO CENTER) '_8"O DIP DRAIN PIPE CONTRACTOR SHALL CORE -DRILL THE HOLE FOR THE 8"0 DIP IN THE FIELD. PRECASTER SHALL OMIT REINFORCEMENT IN THIS AREA. 8"0 EMERGENCY DIP DRAIN TRASHRACK DETAILS N.T.S. NOTES: 0 aM -0 NOTES: INSTALL ALL STEPS PROTRUDING 4" FROM INSIDE FACE OF STRUCTURE WALL. ENDWALL DIMENSIONS Z O C13< ;i Z STEPS DIFFERING IN DIMENSIONS, CONFIGURATION, OR MATERIALS FROM THOSE SHOWN MAY ALSO BE USED PROVIDED THE CONTRACTOR HAS FURNISHED Q Q H 0 0 THE ENGINEER WITH DETAILS OF THE PROPOSED STEPS AND HAS RECEIVED WRITTEN APPROVAL FROM THE ENGINEER FOR THE USE OF SUCH STEPS. 1- N 0 SIZE H1(FT.) H2(FT.) D (FT.) Z S ¢ 0 o --� 1.0 #5 @ B" 1.25/2.00 2.00/3.75 o 00�n� 5.50/6.00 #5 @ B" 1.25/2.00 " =mzM .50/3.75 I 1., #5 @ 8" W <<LL� 3.00/4.25 1.50/2.50 3.50/3.75 6.50/6.75 2.0 #5 f-U�O .2-- _00-n 1" 1.75/2.50 .00/4.25 7.50/8.25 2.5 F--=~ZW @ B" 2.50/3.50 4.00/6.00 2.00/3.00 .50/5.50 10.00/11.50 3.0 #5 @ B" 3.00/3.50 5.00/6.00 2.75/3.50 .25/5.75 11.50/11.75 (f0) 0 #5 §/8" ---►{ 3.25/4.50 6.0016.75 �� I T 1 Cil 0- T � Z 4.0 #5 @ 8" 3.50/4.50 i � W T .50/6.75 13.00/13.25 4.5 #5 1� PLAN 6.50/8.50 SIDE .00/9.25 13.50/15.75 PLAN SIDE @ 8" 4.50/5.00 ELEVATION 3.25/4.00 .25/9.25 13.75/15.75 ELEVATIONOf - @ B" 4.50/5.00 7.50/8.50 3.25/4.00 .25/9.25 14.00/15.75 6.0 #5 @ 8" �1 z I I 3.25/4.00 1 7.75/9.25 14.75/16.75 cc CL 8 H 0 W W r- I„ 1 0 ( 14 N _ ' CAST IRON CAST IRON z ELEVATION ELEVATION W M N (A > cc p 0 Q 1" 0A 1 #8 BAR OR Q fi 1 GALV'D. Z N C mz _ r� 0 T =¢ Z (A M 0 PLAN 3/2" POLYPROPYLENE SIDE PLASTIC SIDE M CD �B„ ELEVATION COMPOSITE PLAN ELEVATION w G r 1� n 1 REINFORCING STEEL 12` ELEVATION NOTE: #3 DEFORMED 12" DO NOT USE IN STEEL ROD SECTION A -A ELEVATION SANITARY SEWER MANHOLES. SHEET 1 OF 1 SHEET 1 OF 1 840.66 840.66 1. CONTRACTOR SHALL PROVIDE A JOINT IN THE OUTLET BARREL NO MORE THAN 5 -FT FROM THE RISER. 1" THICK JOINT CONCRETE COLLAR FILLER MATERIAL (SEE DETAIL ° ° SHEET SW -62) MAINTENANCE ACCESS STEPS d ° d ° N.T.S. 4 a °a 4 Q 24"0 O-RING RCP 4 4 4 '. d FLOW 24"0 O-RING RCP FLOW 4 d ------ a--s-.-a - ° ,4' d d d Q4. Q ° 4 ° ° d 4 ° 4 °'° 4 d d a q4 v Z 4. M ° ° ° O� oC0 1" THICK JOINT H • z NOTES: Q d $ . 1" THICK JOINT Cn O 1- FILLER MATERIAL > F -i O W1 FT.) D g * THIS PRECAST ENDWALL MAY BE USED FOR THE FOLLOWING rz„i GC x o FILLER MATERIALr-ANTI-FLOTATION m - Z iI =i STANDARDS: 838.01 , 838.11 , 838.21 , 838.27, 838.33, U_ _j a "Z BLOCK DI � F 838.39, 838.51, 838.57, 638.63 AND 838.69. O O GO = CONCRETE TOP VIEW SIDE VIEW = O > m * FORINSPRECAST S WITH WINGS 838. F- U cc O C'3 ANTI -FLOTATION = cn 0 0 1-O" 1 -o ` * ¢ BLOCK Z H O r -n USE 4000 PSI CONCRETE. F- = Z W • 00" * PROVIDE ALL REINFORCING STEEL WHICH MEETS ASTM A615 O I- LL O J C7 I D - FOR GRADE 60 AND WELDED WIRE FABRIC CONFORMING 0 O (j Q D O I TO ASTM A185 WITH 2" MIN. CLEARANCE. Z �--�� RISER BARREL/CRADLE CONNECTION DETAIL <H H2 H2 * PLACE LIFT HOLES OR PINS IN ACCORDANCE WITH CL O CS/RCP I OSHA STANDARD 1926.704. LLLJ O N.T.S. z H1 H1 I * PIPE TO BE OR UTED INTO HEADWALL AT JOB SITE BY ' I CONTRACTOR fO * ALL ELEMENTS RECAST TO MEET ASTM C913. 1' 0" ------ * WELDED WIRE FABRIC MAY BE SUBSTITUTED FOR REBAR il- AS LONG AS TH SAME AREA OF STEEL IS PROVIDED. * CHAMFER ALL CORNERS 1" OR HAVE A RADIUS OF 1". 8"0 C.(TYP.)6" B" O.C.(TYP.) _1 REFER TO CHART REFER TO CHART 0 .0 m FOR BAR SIZE FOR BAR SIZE NOTE: THE MIN MUM BAR SIZE SHALL BE #5 BARS Y '� Z ELEVATION AT 8" CTS.THE CONTRACTOR WILL HAVE THE OPTION 0 J U) Gi SIDE TO INCREASE THIS BAR SIZE AS NEEDED. M U- 4; 0 CD 3� RISER OUTLET STRUCTURE m > y z Z s cn 4" PVC CAP WITH d N D w2 (FT.) SCREW TYPE PLUGCl) z TOP EL. = 842.00 _ D M M 4 p „ H m D 1 10 2 M R, m r Z Z D o ° 4"0 PVC SIPHON 0 M1 INVERT THROUGH RISER EL. = 841.00 INVERT EL. = 841.00 (NWSE)cn � 6` Q M r PLAN i d � 8" r BOTTOM EL. = 840.50 4 SHEET i OF 1 SHEET 1 OF 1 v - 838.80 1838.80 v m 3 m 01 4" PVC CAP WITH 2.25"0 DRILLED ORIFICE U .8. l 1 OUTLET ENDWALL DETAILS 11 SIPHON OUTLET DETAIL ' N.T.S. Z N.T.S. z } FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION tl�lavv'_" ww� ,k The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER r� V 1Z z�or-01 W�wN �N d W a W ENDWALL DIMENSIONS ® Q FT. MINIMUM MIN./MAX. MIN./MAX. MIN./MAX. AIIN./MAX. MIN./MAX. PIPE DIA. BAR SIZE H1(FT.) H2(FT.) D (FT.) W1 W2 1.0 #5 @ B" 1.25/2.00 2.00/3.75 1.25/1.75 .00/3.75 5.50/6.00 1.25 #5 @ B" 1.25/2.00 3.00/3.75 1.2512.00 .50/3.75 6.50/6.75 1.50 #5 @ 8" 1.25/2.00 3.00/4.25 1.50/2.50 3.50/3.75 6.50/6.75 2.0 #5 @ 8" 1.50/2.50 4.00/4.75 1.75/2.50 .00/4.25 7.50/8.25 2.5 #5 @ B" 2.50/3.50 4.00/6.00 2.00/3.00 .50/5.50 10.00/11.50 3.0 #5 @ B" 3.00/3.50 5.00/6.00 2.75/3.50 .25/5.75 11.50/11.75 3.5 #5 @ B" 3.25/4.50 6.0016.75 3.25/3.50 .00/6.75 12.00/13.25 4.0 #5 @ 8" 3.50/4.50 6.50/7.00 3.25/3.50 .50/6.75 13.00/13.25 4.5 #5 @ 8" 4.00/5.00 6.50/8.50 3.25/4.00 .00/9.25 13.50/15.75 5.0 #5 @ 8" 4.50/5.00 7.00/8.50 3.25/4.00 .25/9.25 13.75/15.75 5.5 #5 @ B" 4.50/5.00 7.50/8.50 3.25/4.00 .25/9.25 14.00/15.75 6.0 #5 @ 8" 4.50/5.00 7.50/8.50 3.25/4.00 1 7.75/9.25 14.75/16.75 BOTTOM EL. = 840.50 4 SHEET i OF 1 SHEET 1 OF 1 v - 838.80 1838.80 v m 3 m 01 4" PVC CAP WITH 2.25"0 DRILLED ORIFICE U .8. l 1 OUTLET ENDWALL DETAILS 11 SIPHON OUTLET DETAIL ' N.T.S. Z N.T.S. z } FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION tl�lavv'_" ww� ,k The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER r� V 1Z z�or-01 W�wN �N d W a W JAA ® Q OC o W °- DATE 0 ~ J [� r / 0 (V LU CC r z U O0 Z 0 Q 0 C U Z) LU ( I"j N M x Q O CoW z (D V z O Z LUW W CL er 0 LL BOTTOM EL. = 840.50 4 SHEET i OF 1 SHEET 1 OF 1 v - 838.80 1838.80 v m 3 m 01 4" PVC CAP WITH 2.25"0 DRILLED ORIFICE U .8. l 1 OUTLET ENDWALL DETAILS 11 SIPHON OUTLET DETAIL ' N.T.S. Z N.T.S. z } FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION tl�lavv'_" ww� ,k The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER r� V 1Z z�or-01 W�wN �N RYN17010-SWB W JAA ® Q OC _z DATE 0 F- v,Q J [� r / LU �C z U O0 0 U Z) LU ( I"j Z z M `/ Q z o O U CARO< SEAL REVISIONS NO. DATE PLAN INFORMATION PROJECT NO. RYN-17010 FILENAME RYN17010-SWB CHECKED BY JAA DRAWN BY JSM SCALE N.T.S. DATE 11. 26. 2018 SHEET STORMWATER CONTROL MEASURE 'B' DETAILS SW -63 �J I The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER V) V � z�00 NOTE: NOTES: Q 1. AS AN ALTERNATE TO A CONCRETE CRADLE UNDER THE BARREL PIPE (THIS DETAIL), THE CONTRACTOR z 1. A FILTER BLANKET IS TO BE INSTALLED BETWEEN THE RIPRAP AND SOIL FOUNDATION. THE FILTER BLANKET F- MAY CHOOSE TO ELIMINATE THE CONCRETE CRADLE AND USE COMPACTED BACKFILL IF THE ON-SITE WILL CONSIST OF A MINIMUM 4" THICK LAYER OF STONE (NCDOT #57) UNDERLAIN WITH MIRAFI FILTER Q GEOTECHNICAL ENGINEER WILL PROVIDE A NC PE SEALED LETTER CERTIFYING THAT THE COMPACTION WEAVE 700 OR APPROVED EQUIVALENT 00�� UNDER, AROUND, AND ABOVE THE BARREL MEETS THE SPECIFICATIONS OF THE EMBANKMENT COMPACTION REQUIREMENTS AND MOISTURE CONTENT. THIS CERTIFICATION LETTER MUST BE 66" MIN. ou00 CC SUBMITTED TO THE DESIGN ENGINEER BEFORE AS -BUILT CERTIFICATION OF THE FACILITY. THIS SEPARATE LLJ in CERTIFICATION MUST BE SPECIFIC TO THE BARREL PIPE FOR THE FACILITY, AND MUST CLEARLY STATE THAT ALL SOIL MATERIAL UNDER, AROUND, AND ABOVE THE BARREL PIPE MEETS THE BERM AND SOIL 0 NCDOT CLASS "B" RIPRAP 121 6'W 22" THICK 240 O-RING RCP COMPACTION SPECIFICATIONS STATED ON SHEET SW -131. THIS CERTIFICATION IS TO INCLUDE REFERENCE TO BOTH MATERIAL AND COMPACTION, AND MUST STATE THAT ALL MATERIALS UNDER, AROUND, AND U x x ABOVE THE BARREL HAVE BEEN COMPACTED PER THE BERM MATERIAL SPECIFICATIONS (AT LEAST 95% OF - MAXIMUM DRY DENSITY USING ASTM D698 STANDARD PROCTOR) WITH NO VOID SPACES PRESENT. THE ENDWALL PER CONTRACTORS INTENT TO UTILIZE THIS ALTERNATIVE MUST BE STATED PRIOR TO CONSTRUCTION TAKING NCDOT STD. 838.80 PLACE. THIS CONTRACTORS CERTIFICATION MUST BE PRESENTED TO THE DESIGN ENGINEER BEFORE AN 1 - AS -BUILT CERTIFICATION CAN BE ISSUED FOR THIS FACILITY. / (MIN.) ENDWALL PER 18" TYP. \ NCDOT STD. 838.80 a0 a� BARREL PIPE FLOWABLE FILL CRADLE 24"0 O-RING RCP . .Q + •. • ••,. .a. .a. _ 24"0 0 -RING RCP CONSTRUCTION SEQUENCE - -------------- A O a0� O 1. CONSTRUCT FORMWORK FOR PLOWABLE FILL CRADLE ON EXISTING GRADE.JA .,��••• "'.':.• : , \ • ° � '+`' I� 6�------------- O O 2. EXCAVATE TRENCH FOR CRADLE AND BARREL PER DIMENSIONS ON DRAWINGS. 15 ; . �• ' ' •d • d . --------------- 3. PLACE BARREL PIPE ON CONCRETE BLOCKS TO GRADE. CONTRACTOR SHALL WRAP JOINTS WITH 2 -FT WIDE °:. _ t •• O� O ---__----_ ---- - 22" LAYER OF ` j STRIPS OF FABRIC AT THIS STEP. "- '" "•, • • M .• y P P P P4nlO _ P — "B" CLASS "B" RIPRAP , 4. PLACE FLOWABLE FILL FOR CRADLE FOR EACH SECTION FROM ONE SIDE OF THE TRENCH. ALLOW FLOWABLE .'.� A -• .. - " 41' +�' .a :' _ '••'•!'. ' •' + ' '' 75O PSI PLOWABLE FILL 'd •' _I , FILTER BLANKET FILL TO FILL ENTIRE AREA UNDER PIPE AND PIPE HAUNCHES AS TO LEAVE NO VOIDS UNDER THE PIPE BEFORE ,. ,A A , • PLACING PLOWABLE FILL ON THE OPPOSITE SIDE OF THE TRENCH. PLACE ENTIRE CRADLE AS ONE LIFTI• - s a• „ . (VERTICALLY) PER DRAWINGS. 12" MIN.' . a•d f .' d . " .° ' d '.• d 9 .. •• . ° d: ' FILTER BLANKET (SEE NOTE) a 5. FLOWABLE FILL CRADLE MAY BE ELIMINATED PER RECOMMENDATION FROM THE ON-SITE GEOTECHNICAL _ + ` ' d•''' ENGINEER. ANY DEVIATION FROM THIS DETAIL SHALL BE SUBMITTED TO AND REVIEWED BY THE DESIGN • 6. ENGINEER PRIOR TO IMPLEMENTATION. IF THE CRADLE IS ELIMINATED, THEN A LETTER FROM AN NC PE - - CERTIFYING THAT ALL SOIL MATERIAL UNDER, AROUND, AND ABOVE THE BARREL PIPE MEETS THE BERM 12' MATERIAL SPECIFICATIONS STATED ON SHEET SW -61 IS REQUIRED. 6. ALLOW CRADLE TO CURE FOR A MINIMUM OF 7 DAYS BEFORE ANY VIBRATING COMPACTION EQUIPMENT IS PLAN SECTION A -A USED IN THE VICINITY OF THE BARREL PIPE. 7. TRENCH TO BE BACKFILLED IN 5" LIFTS WHEN COMPACTION IS BY HAND. BACKFILL IS IN 8" LIFTS WHEN CONDUCTED BY MACHINE. MINIMUM OF 2 FEET COVER MUST BE PRESENT ON 24"0 RCP BEFORE DRIVING OVER WITH HEAVY EQUIPMENT. OUTLET 13ARREL VELOCITY DISSIPATOR 24" CONCRETE CRADLE DETAIL N.T.S. N.T.S. 8'-6- 2'-6" O.D. (2) 4" PERFORATED, CORRUGATED HDPE PIPE (ADS N•-12 OR APPROVED EQUIVALENT) 1 24"0 0 -RING RCP 1 I KUA)I O�O�O�O o O O o O O O O CID D C000�o 0000 P P O P P PP O 00000000 O P P O 4'-0" O�o0�0�0� �OO� P aa�o�o�o ��o O�O�OOaO� a a a a P a P P o�o�JUa�o o o a a oa�o�o�a �o�a cO�ocO� ENDWALL PER NCDOT STD. 838.80 NOTE: 4" WEEPHOLES TO BE PROVIDED WITH VARMIT GUARD ON DOWNSTREAM SIDE ES WASHED STONE ENCASED IN NON -WOVEN NCA AND GALVANIZED HARDWARE CLOTH ON UPSTREAM SIDE (Y4" MAXIMUM OPENINGS) GEOTEXTILE FABRIC (MIRAFI 180N OR EQUIVALENT) PROPOSED GRADE 3' MIN. 3' MIN. 6" MIN. III _ _ I I 1-1 I I -I I I I 1-1 11-1 11-1 11-1 I I-1 I I -I I III -11- ENDWALL PER NCDOT STD. 838.80 oo0ooao O �ooaooa ooaoo , O O O P O II1= I I-1MIN. 111-10 0 0 0 o III -III -III a a a o 0 --------- -- - - - - ENDWALL PER NCDOT STD. 838.80 O�O O O� Pa a --- P oao� 24"0 O-RING RCP 4.5' MIN. FLOW Oa oa oa oa oa I O O Oo 1 24» 0 0 -RING RCP I Do '�., aOoO O� �a aO�o 000aa o00o ao ,,� ,' MIN. aO O O O O O O O P O o%a�a oO oa oa (2) 4" PERFORATED, CORRUGATED HDPE PIPE NO. 67 WASHED STONE (ADS N-12 OR NO. 67 WASHED STONE ENCASED IN NON -WOVEN FILTER FABRIC (MIRAFI 180N APPROVED EQUIVALENT) ENCASED IN NON -WOVEN GEOTEXTILE FABRIC (MIRAFI (2) 4" PERFORATED, OR EQUIVALENT) 180N OR EQUIVALENT) CORRUGATED HDPE PIPE (ADS N-12 OR APPROVED EQUIVALENT) SPILLWAY FILTER DETAIL N.T.S. FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION �J I The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER V) V � z�00 CAI? 04 FESS/p• ' SEAL - 3 REVISIONS N0. DATE PLAN INFORMATION PROJECT NO. RYN-17010 FILENAME RYN17010-SWB CHECKED BY JAA DRAWN BY JSM SCALE N.T.S. DATE 11. 26. 2018 SHEET STORMWATER CONTROL MEASURE 'B' DETAILS SW -B4 W�wN WQ Q z F- J W Q Z U 00�� ou00 CC :Dz LLJ in Q Z 0 O U CAI? 04 FESS/p• ' SEAL - 3 REVISIONS N0. DATE PLAN INFORMATION PROJECT NO. RYN-17010 FILENAME RYN17010-SWB CHECKED BY JAA DRAWN BY JSM SCALE N.T.S. DATE 11. 26. 2018 SHEET STORMWATER CONTROL MEASURE 'B' DETAILS SW -B4 STORMWATER CONTROL MEASURE '6' LANDSCAPE SPECIFICATIONS LEGEND QTY. SYM. SCIENTIFIC NAME COMMON NAME HATCH TYPE SPACING SHALLOW LAND SEEDBED PREPARATION 1. CHISEL COMPACTED AREAS AND SPREAD TOPSOIL 3 INCHES DEEP OVER ADVERSE SOIL CONDITIONS, IF AVAILABLE. 2. RIP THE ENTIRE AREA TO 6 INCHES DEPTH. 3. REMOVE ALL LOOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING SURFACE REASONABLY SMOOTH AND UNIFORM. 4. PER ONE TIME ONLY, APPLY AGRICULTURAL LIME, FERTILIZER, AND SUPERPHOSPHATE UNIFORMLY AND MIX WITH SOIL. 5. CONTINUE TILLAGE UNTIL A WELL -PULVERIZED, FIRM REASONABLY UNIFORM SEEDBED IS PREPARED 4 TO 6 INCHES DEEP. 6. SEED ON A FRESHLY PREPARED SEEDBED AND COVER. 7. MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH. 8. INSPECT ALL SEEDED AREAS AND MAKE NECESSARY REPAIRS OR RESEEDINGS WITHIN THE PLANTING SEASON, IF POSSIBLE. AFTER PERMANENT COVER IS ESTABLISHED. 9. CONSULT CONSERVATION INSPECTOR ON MAINTENANCE TREATMENT PERMANENT SEEDING SCHEDULE (DAM EMBANKMENTS) SEEDING DATE SEEDING MIXTURE APPLICATION RATE APRIL 15 -JUNE 30 BERMUDAGRASS 25 LBS/AC SOILAMENDMENTS APPLY LIME AND FERTILIZER FOLLOWING RECOMMENDATIONS OF SOIL TESTS OR APPLY 3,000 LB/AC GROUND AGRICULTURE LIMESTONE AND 500 LB/AC 10-10-10 FERTILIZER. MULCH APPLY 4000 LB/AC STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE REFERTILIZE THE FOLLOWING APRIL WITH 50 LB/AC NITROGEN. REPEAT AS GROWTH CONTINUES. MAY BE MOWED ONLY ONCE PER YEAR. SEEDING NOTES USE BERMUDAGRASS ONLY ON ISOLATED SITES WHERE IT CANNOT BECOME A PEST. NOTE: PERMANENT SEEDING SCHEDULE IS FOR SLOPES OF THE BASIN, TOP OF BERM, AND BASIN FLOOR. PLANTING INSTRUCTIONS PLANTING TECHNIQUES A. INSURE THAT ROOTS, ONCE REMOVED FROM POT, ARE STRAIGHTENED AND FACE DOWNWARD. B. CREATE PLANTING AREA FOR EACH PLANT AND EXCAVATE PIT. C. PLACE PLANTS IN PIT INSURING ROOTS ARE FACING COMPLETELY DOWNWARD. D. HEEL IN SOIL AROUOND PLANT AND PROCEED TO NEXT PLANTING LOCATION. E. NEWLY PLANTED PLANTS NEED TO BE FASTENED TO THE SUBSTRATE FOR THE ESTABLISHMENT OF NEW ROOTS. F. ROOTS SHALL BE SPREAD IN THEIR NORMAL POSITION. ALL BROKEN OR FRAYED ROOTS HALL BE CUT OFF CLEANLY. G. THE DIAMETER OF THE PITS FOR ALL VEGETATIVE STOCK SHALL BE AT LEAST THREE TIMES THE DIAMETER OF THE ROOT MASS. PLANT PIT WALL SHALL BE SCARIFIED PRIOR TO PLANT INSTALLATION. H. SET THE PLANTS UPRIGHT, IN THE CENTER OF THE PIT. THE BOTTOM OF THE ROOT MASS SHOULD BE RESTING ON UNDISTURBED SOIL. I. PLACE THE BACKFILL AROUND THE BASE AND SIDES OF THE ROOT MASS, AND WORK EACH LAYER TO SETTLE BACKFILL AND TO ELIMINATE VOIDS AND AIR POCKETS. WHEN PIT IS APPROXIMATELY 2/3 FULL, WATER THOROUGHLY BEFORE PLACING REMAINDER OF THE BACKFILL. WATER AGAIN AFTER PLACING FINAL LAYER OF BACKFILL. J. BROKEN OR DAMAGED PARTS WILL BE CUT BACK TO UNDAMAGED TISSUE, LEAVING AS MUCH GREEN BASAL TISSUE AS POSSIBLE ABOVE THE ROOTS. IF MORE THAN FIFTY PERCENT (50%) OF THE PLANT IS DAMAGED THEN CONTRACTOR SHALL REPLACE THE PLANT. CONTAINER STOCK/ BARE ROOT A. STOCK SHALL HAVE BEEN GROWN IN A CONTAINER LONG ENOUGH FOR THE ROOT SYSTEM TO HAVE DEVELOPED SUFFICIENTLY TO HOLD ITS SOIL TOGETHER ONCE REMOVED FROM THE CONTAINER. B. CONTAINER PLANTS WILL NEED TO BE WATERED REGULARLY AND PLACED IN SHADY CONDITIONS UNTIL PLANTING OCCURS. C. BARE ROOT PLANTS ARE FOR IMMEDIATE PLANTING, OTHERWISE SEE D) BELOW. D. IF BARE ROOTS SPECIMENS ARE NOT TO BE PLANTED WITHIN FOUR (4) DAYS, TEMPORARY HOLDING OF BARE ROOT SPECIMENS ARE TO BE COVERED ENTIRELY BY A SUITABLE MEDIUM (ETC. SOIL, SAWDUST, MULCH OR THE LIKE) AND WATERED REGULARLY SO AS TO NOT DRY OUT. PLANT LOCATIONS A. NEW PLANTINGS SHALL BE LOCATED WHERE SHOWN ON PLAN EXCEPT WHERE CHANGES HAVE BEEN MADE IN PROPOSED CONSTRUCTION. B. NECESSARY ADJUSTMENTS SHALL BE MADE ONLY AFTER APPROVAL BY THE OWNER OR THE OWNER'S REPRESENTATIVE. WATER WATER SHALL BE POTABLE AND SHALL NOT CONTAIN ELEMENTS TOXIC TO PLANT LIFE. TEMPORARY SEEDING SCHEDULE SEEDING DATE SEEDING MIXTURE APPLICATION RATE JAN 1 - MAY 1 RYE (GRAIN) 120 LBS/AC KOBE LESPEDEZA 50 LBS/AC MAY 1 - AUG 15 GERMAN MILLET 40 LBS/AC AUG 15 - DEC 31 RYE (GRAIN) 120 LBS/AC SOIL AMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/AC GROUND AGRICULTURE LIMESTONE AND 750 LB/AC 10-10-10 FERTILIZER (FROM AUG 15 - DEC 31, INCREASE 10-10-10 FERTILIZER TO 1000 LB/AC). MULCH APPLY 4000 LB/AC STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE JAN 1 - AUG 15: REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE, AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. AUG 15 - DEC 31: REPAIR AND REFERTILIZE DAMAGED AREAS IMMEDIATELY. TOP DRESS WITH 50 LB/AC OF NITROGEN IN MARCH. IF IT IS NECESSARY TO EXTEND TEMPORARY COVER BEYOND JUNE 15, OVERSEED WITH 50 LB/AC KOBE LESPEDEZA IN LATE FEBRUARY OR EARLY MARCH. NOTE: USE THE TEMPORARY SEEDING SCHEDULE ONLY WHEN DATE IS NOT CORRECT TO USE THE PERMANENT SEEDING SCHEDULE. I I I / 79 lb A / � � / / / / I � / / IIII IIII Ili 11/11/ TW= 71.75 I i BW=848.00 - _ 868. s \ ► I W=84 0 I / / / / // 40 871. (1 j/ //// / lb/ I B X848. / � / I k 200 PC i � II 1111 11 ,11` 11 1\ � ' k i J W=847.007.00 / RETAINING WALL / (TYP.) (DESIGN _ BY OTHERS) —// I l l -l- - - - � �o 40' TEMPORARY SEWER EASEMENT 20' PERMANENT SEWER EASEMENT >< I BTW= , 0 � BW 844, 0 —86 .00 B =82.5/ 100 STREAM BUFFER (TYP.) i /10'ASPHALT GREENWAY STORMWATER CONTROL MEASURE MAINTENANCE/ACCESS EASEMENT / / GRAPHIC SCALE /r- - //// / 0 10 20 40 1 inch = 20 ft. STORMWATER CONTROL MEASURE 'B' LANDSCAPE PLAN 1" = 20' FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER (vI�I V � z�� �Do FILENAME RYN17010-SWB W ?:wN LU 228 Al ASCLEPIAS INCARNATE SWBMP MILKWEED z 4 -INCH CONTAINER 24" O.C. J Z o �C 213 EF EUPATORIADELPHUS JOE PYE WEED D D 4 -INCH CONTAINER 24" O.C. FISTULOSUS 0 0 225 LCLOBELIA CARDINALIS CARDINAL FLOWER 4 -INCH CONTAINER 24" O.C. SHALLOW WATER 172 IV IRIS VIRGINIANA BLUE FLAG IRIS 4 -INCH CONTAINER 24" O.C. 200 PC PONTEDERIA CORDATA PICKERELWEED ++++ + + + 4 -INCH CONTAINER 24" O.C. 207 ST SCHOENOPLECTUS SOFT -STEM BULRUSH 4 -INCH CONTAINER 24" O.C. TABERNAEMONTANI SEEDBED PREPARATION 1. CHISEL COMPACTED AREAS AND SPREAD TOPSOIL 3 INCHES DEEP OVER ADVERSE SOIL CONDITIONS, IF AVAILABLE. 2. RIP THE ENTIRE AREA TO 6 INCHES DEPTH. 3. REMOVE ALL LOOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING SURFACE REASONABLY SMOOTH AND UNIFORM. 4. PER ONE TIME ONLY, APPLY AGRICULTURAL LIME, FERTILIZER, AND SUPERPHOSPHATE UNIFORMLY AND MIX WITH SOIL. 5. CONTINUE TILLAGE UNTIL A WELL -PULVERIZED, FIRM REASONABLY UNIFORM SEEDBED IS PREPARED 4 TO 6 INCHES DEEP. 6. SEED ON A FRESHLY PREPARED SEEDBED AND COVER. 7. MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH. 8. INSPECT ALL SEEDED AREAS AND MAKE NECESSARY REPAIRS OR RESEEDINGS WITHIN THE PLANTING SEASON, IF POSSIBLE. AFTER PERMANENT COVER IS ESTABLISHED. 9. CONSULT CONSERVATION INSPECTOR ON MAINTENANCE TREATMENT PERMANENT SEEDING SCHEDULE (DAM EMBANKMENTS) SEEDING DATE SEEDING MIXTURE APPLICATION RATE APRIL 15 -JUNE 30 BERMUDAGRASS 25 LBS/AC SOILAMENDMENTS APPLY LIME AND FERTILIZER FOLLOWING RECOMMENDATIONS OF SOIL TESTS OR APPLY 3,000 LB/AC GROUND AGRICULTURE LIMESTONE AND 500 LB/AC 10-10-10 FERTILIZER. MULCH APPLY 4000 LB/AC STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE REFERTILIZE THE FOLLOWING APRIL WITH 50 LB/AC NITROGEN. REPEAT AS GROWTH CONTINUES. MAY BE MOWED ONLY ONCE PER YEAR. SEEDING NOTES USE BERMUDAGRASS ONLY ON ISOLATED SITES WHERE IT CANNOT BECOME A PEST. NOTE: PERMANENT SEEDING SCHEDULE IS FOR SLOPES OF THE BASIN, TOP OF BERM, AND BASIN FLOOR. PLANTING INSTRUCTIONS PLANTING TECHNIQUES A. INSURE THAT ROOTS, ONCE REMOVED FROM POT, ARE STRAIGHTENED AND FACE DOWNWARD. B. CREATE PLANTING AREA FOR EACH PLANT AND EXCAVATE PIT. C. PLACE PLANTS IN PIT INSURING ROOTS ARE FACING COMPLETELY DOWNWARD. D. HEEL IN SOIL AROUOND PLANT AND PROCEED TO NEXT PLANTING LOCATION. E. NEWLY PLANTED PLANTS NEED TO BE FASTENED TO THE SUBSTRATE FOR THE ESTABLISHMENT OF NEW ROOTS. F. ROOTS SHALL BE SPREAD IN THEIR NORMAL POSITION. ALL BROKEN OR FRAYED ROOTS HALL BE CUT OFF CLEANLY. G. THE DIAMETER OF THE PITS FOR ALL VEGETATIVE STOCK SHALL BE AT LEAST THREE TIMES THE DIAMETER OF THE ROOT MASS. PLANT PIT WALL SHALL BE SCARIFIED PRIOR TO PLANT INSTALLATION. H. SET THE PLANTS UPRIGHT, IN THE CENTER OF THE PIT. THE BOTTOM OF THE ROOT MASS SHOULD BE RESTING ON UNDISTURBED SOIL. I. PLACE THE BACKFILL AROUND THE BASE AND SIDES OF THE ROOT MASS, AND WORK EACH LAYER TO SETTLE BACKFILL AND TO ELIMINATE VOIDS AND AIR POCKETS. WHEN PIT IS APPROXIMATELY 2/3 FULL, WATER THOROUGHLY BEFORE PLACING REMAINDER OF THE BACKFILL. WATER AGAIN AFTER PLACING FINAL LAYER OF BACKFILL. J. BROKEN OR DAMAGED PARTS WILL BE CUT BACK TO UNDAMAGED TISSUE, LEAVING AS MUCH GREEN BASAL TISSUE AS POSSIBLE ABOVE THE ROOTS. IF MORE THAN FIFTY PERCENT (50%) OF THE PLANT IS DAMAGED THEN CONTRACTOR SHALL REPLACE THE PLANT. CONTAINER STOCK/ BARE ROOT A. STOCK SHALL HAVE BEEN GROWN IN A CONTAINER LONG ENOUGH FOR THE ROOT SYSTEM TO HAVE DEVELOPED SUFFICIENTLY TO HOLD ITS SOIL TOGETHER ONCE REMOVED FROM THE CONTAINER. B. CONTAINER PLANTS WILL NEED TO BE WATERED REGULARLY AND PLACED IN SHADY CONDITIONS UNTIL PLANTING OCCURS. C. BARE ROOT PLANTS ARE FOR IMMEDIATE PLANTING, OTHERWISE SEE D) BELOW. D. IF BARE ROOTS SPECIMENS ARE NOT TO BE PLANTED WITHIN FOUR (4) DAYS, TEMPORARY HOLDING OF BARE ROOT SPECIMENS ARE TO BE COVERED ENTIRELY BY A SUITABLE MEDIUM (ETC. SOIL, SAWDUST, MULCH OR THE LIKE) AND WATERED REGULARLY SO AS TO NOT DRY OUT. PLANT LOCATIONS A. NEW PLANTINGS SHALL BE LOCATED WHERE SHOWN ON PLAN EXCEPT WHERE CHANGES HAVE BEEN MADE IN PROPOSED CONSTRUCTION. B. NECESSARY ADJUSTMENTS SHALL BE MADE ONLY AFTER APPROVAL BY THE OWNER OR THE OWNER'S REPRESENTATIVE. WATER WATER SHALL BE POTABLE AND SHALL NOT CONTAIN ELEMENTS TOXIC TO PLANT LIFE. TEMPORARY SEEDING SCHEDULE SEEDING DATE SEEDING MIXTURE APPLICATION RATE JAN 1 - MAY 1 RYE (GRAIN) 120 LBS/AC KOBE LESPEDEZA 50 LBS/AC MAY 1 - AUG 15 GERMAN MILLET 40 LBS/AC AUG 15 - DEC 31 RYE (GRAIN) 120 LBS/AC SOIL AMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/AC GROUND AGRICULTURE LIMESTONE AND 750 LB/AC 10-10-10 FERTILIZER (FROM AUG 15 - DEC 31, INCREASE 10-10-10 FERTILIZER TO 1000 LB/AC). MULCH APPLY 4000 LB/AC STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE JAN 1 - AUG 15: REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE, AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. AUG 15 - DEC 31: REPAIR AND REFERTILIZE DAMAGED AREAS IMMEDIATELY. TOP DRESS WITH 50 LB/AC OF NITROGEN IN MARCH. IF IT IS NECESSARY TO EXTEND TEMPORARY COVER BEYOND JUNE 15, OVERSEED WITH 50 LB/AC KOBE LESPEDEZA IN LATE FEBRUARY OR EARLY MARCH. NOTE: USE THE TEMPORARY SEEDING SCHEDULE ONLY WHEN DATE IS NOT CORRECT TO USE THE PERMANENT SEEDING SCHEDULE. I I I / 79 lb A / � � / / / / I � / / IIII IIII Ili 11/11/ TW= 71.75 I i BW=848.00 - _ 868. s \ ► I W=84 0 I / / / / // 40 871. (1 j/ //// / lb/ I B X848. / � / I k 200 PC i � II 1111 11 ,11` 11 1\ � ' k i J W=847.007.00 / RETAINING WALL / (TYP.) (DESIGN _ BY OTHERS) —// I l l -l- - - - � �o 40' TEMPORARY SEWER EASEMENT 20' PERMANENT SEWER EASEMENT >< I BTW= , 0 � BW 844, 0 —86 .00 B =82.5/ 100 STREAM BUFFER (TYP.) i /10'ASPHALT GREENWAY STORMWATER CONTROL MEASURE MAINTENANCE/ACCESS EASEMENT / / GRAPHIC SCALE /r- - //// / 0 10 20 40 1 inch = 20 ft. STORMWATER CONTROL MEASURE 'B' LANDSCAPE PLAN 1" = 20' FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER (vI�I V � z�� 0 �Do FILENAME RYN17010-SWB W ?:wN LU z W Q DC z SHEET J Z o �C zLU U 0 0 02 0 �Do FILENAME RYN17010-SWB cc Z) LU z W 1" = 20' DATE G SHEET Z o O F_ U Bill," �N CARO '�.. .� SEAL � _ 33782 :4 REVISIONS N0. DATE PLAN INFORMATION PROJECT NO. RYN-17010 FILENAME RYN17010-SWB CHECKED BY JAA DRAWN BY JSM SCALE 1" = 20' DATE 11. 26. 2018 SHEET STORMWATER CONTROL MEASURE 'B' LANDSCAPE PLAN SW -BLS STORMWATER CONTROL MEASURE 'C' CONSTRUCTION SPECIFICATIONS 6ENERAL NU I ES 1. PRIOR TO CONSTRUCTION, ANY DISCREPANCIES IN THE PLANS AND NOTES SHALL BE BROUGHT TO THE DESIGN ENGINEER'S ATTENTION IMMEDIATELY. 2. THE FINAL CERTIFICATION FOR THIS FACILITY WILL INCLUDE A CERTIFICATION BY THE ON-SITE GEOTECHNICAL ENGINEER THAT THE PROJECT WAS CONSTRUCTED PER THE APPROVED PLANS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE ON-SITE GEOTECHNICAL ENGINEER FOR OBSERVATION AND TESTING SUCH THAT THE ON-SITE GEOTECHNICAL ENGINEER CAN CERTIFY THE CONSTRUCTION. 3. ALL CONSTRUCTION ACTIVITY RELATED TO THE PROPOSED STORMWATER MANAGEMENT FACILITY SHALL BE PER THE DETAILS AND SPECIFICATIONS SHOWN IN THESE DRAWINGS. SOILS, COMPACTION, AND OTHER MISCELLANEOUS DETAILS AND SPECIFICATIONS MAY BE MODIFIED PER THE RECOMMENDATIONS OF THE ON-SITE GEOTECHNICAL ENGINEER. HOWEVER, PRIOR TO IMPLEMENTATION, THE DESIGN ENGINEER SHALL BE NOTIFIED OF ANY DEVIATION FROM THESE DESIGN DRAWINGS, INCLUDING SHOP DRAWINGS FOR ANY PROPOSED MODIFICATION. 4. THE CONTRACTOR SHALL REFER TO THE LANDSCAPE PLAN FOR THE PERMANENT PLANTING PLAN/SCHEDULE. PLEASE NOTE THAT NO TREES/SHRUBS OF ANY TYPE MAY BE PLANTED ON THE PROPOSED DAM EMBANKMENT (FILL AREAS). 5. DURING THE INITIAL STAGES OF CONSTRUCTION, THE STORMWATER MANAGEMENT FACILITY MAY BE USED AS A SEDIMENT BASIN FOR EROSION CONTROL PURPOSES. IF SO, THE CONTRACTOR SHALL FOLLOW THE GENERAL CONSTRUCTION SEQUENCE BELOW: 5.1. THE CONTRACTOR SHALL CONSTRUCT THE ENTIRE FACILITY (PERMANENT OUTLET STRUCTURE, DAM, ETC.) WITH THE EXCEPTION OF THE INTERIOR FINE GRADING FOR THE FACILITY. THE INTERIOR FINE GRADING WILL BE CONSTRUCTED ONCE THE EROSION CONTROL PHASE IS COMPLETE. 5.2. THE TEMPORARY DRAW DOWN RISER (OR SKIMMER) SHALL BE CONNECTED TO THE PERMANENT 8"0 DIP DRAIN PIPE. 5.3. ONCE THE UPSTREAM DRAINAGE AREA IS STABILIZED AND THE EROSION CONTROL INSPECTOR APPROVES THE REMOVAL OF THE SEDIMENT BASIN, THE CONTRACTOR SHALL REMOVE THE TEMPORARY DRAW DOWN RISER (OR SKIMMER) AND CLEAN-OUT THE BASIN. ALL SEDIMENT, TRASH, ETC. SHALL BE DISPOSED OF PROPERLY (I.E. - PLACED IN A LANDFILL) AND NOT STOCKPILED IN AN AREA WHERE WATER QUALITY COULD BE ADVERSELY AFFECTED. 5.4. ONCE THE BASIN IS CLEANED OUT, AND ALL EROSION CONTROL DEVICES REMOVED, THE CONTRACTOR SHALL CONSTRUCT THE INTERIOR GRADING SHOWN ON THIS SHEET. 5.5. ONCE THE GRADING IS COMPLETE, THE CONTRACTOR SHALL REQUEST AN ON-SITE INSPECTION AND AN AS -BUILT SURVEY PRIOR TO INSTALLATION OF THE STORMWATER MANAGEMENT FACILITY PLANTS. IF THE CONTRACTOR PLANTS THE PROPOSED VEGETATION PRIOR TO AN AS -BUILT SURVEY (AND SUBSEQUENT APPROVAL), ANY CHANGES TO THE GRADING / RE -PLANTING OF PLANTS WILL BE AT THE CONTRACTOR'S EXPENSE. 5.6. ONCE THE ENGINEER HAS APPROVED THE AS -BUILT GRADING, THE CONTRACTOR SHALL PLANT THE PROPOSED STORMWATER MANAGEMENT FACILITY PLANTS SHOWN ON THE LANDSCAPE PLAN FOR THE FACILITY. AFTER COMPLETION OF THE PLANTING, THE LANDSCAPE CONTRACTOR SHALL PROVIDE A LETTER TO THE ENGINEER CERTIFYING THAT THE PLANTS HAVE BEEN INSTALLED PER THE APPROVED STORMWATER MANAGEMENT FACILITY PLANTING PLAN. 6. THE GRADES SHOWN ON THIS PLAN ARE FINISHED GRADES. IF THE EXISTING SOIL LAYER ALONG THE FOREBAY BERM IN THE PROPOSED WETLAND AFTER CONSTRUCTION / COMPACTION IS NOT DETERMINED SUITABLE BY A LANDSCAPE PROFESSIONAL FOR THE WETLAND PLANTINGS, THEN THE CONTRACTOR SHALL AMEND THE PLANTING AREA OF THE WETLAND AS DIRECTED BY A LANDSCAPE PROFESSIONAL. 7. ANY REMOVED TOPSOIL SHALL BE STOCKPILED FOR USE IN PLANTING (SEEDING) ON THE DAM EMBANKMENT ONCE FINAL GRADES (AS SHOWN ON THE GRADING PLAN) HAVE BEEN ESTABLISHED WITH COMPACTED FILL. PRIOR TO TOPSOIL INSTALLATION, THE CONTRACTOR SHALL SCARIFY THE THE TOP 2"-3" OF THE BERM SECTION TO PROMOTE BONDING OF THE TOPSOIL WITH THE COMPACTED FILL. THE TOPSOIL DEPTH SHALL RANGE FROM 3"-4" ON THE DAM EMBANKMENT. PLEASE NOTE THE STOCKPILED TOPSOIL SHALL BE AMENDED, AS DIRECTED BY A LANDSCAPE PROFESSIONAL, PRIOR TO INSTALLATION ON THE EMBANKMENT. 8. IT IS ANTICIPATED THAT DEWATERING WILL BE NECESSARY IN THE EXCAVATION AREAS (E.G. - EMBANKMENT SUB GRADE, INTERIOR PORTIONS OF THE STORMWATER FACILITY, KEY TRENCH, ETC.). THEREFORE, THE CONTRACTOR SHALL FURNISH, INSTALL, OPERATE, AND MAINTAIN ANY PUMPING EQUIPMENT, ETC.. NEEDED FOR REMOVAL OF WATER FROM VARIOUS PARTS OF THE STORMWATER FACILITY SITE. DURING PLACEMENT OF FILL WITHIN THESE AREAS, THE CONTRACTOR SHALL KEEP THE WATER LEVEL BELOW THE BOTTOM OF THE EXCAVATION / CONSTRUCTION AREAS. THE MANNER IN WHICH THE WATER IS REMOVED SHALL BE SUCH THAT THE EXCAVATION BOTTOM AND SIDE SLOPES ARE STABLE, WITH NO SEDIMENT DISCHARGED FROM THE SITE (I.E. PUMPED WATER MAY NEED TO BE DIRECTED TO AN APPROVED EROSION CONTROL DEVICE SUCH AS A DIRT BAG (ACF ENVIRONMENTAL), OR ENGINEER APPROVED EQUIVALENT, PRIOR TO DISCHARGE). BERM AND SOIL COMPACTION SPECIFICATIONS 1. PRIOR TO CONSTRUCTION, THE ON-SITE GEOTECHNICAL ENGINEER SHALL IDENTIFY BORROW / FILL AREAS AND VERIFY THEIR SUITABILITY FOR USE WITHIN THE DAM EMBANKMENT. ALSO, THE ON-SITE GEOTECHNICAL ENGINEER SHALL PERFORM STANDARD PROCTORS ON THE PROPOSED BORROW MATERIAL TO ENSURE THAT OPTIMUM MOISTURE CONTENT AND COMPACTION CAN BE ACHIEVED / CONTROLLED DURING CONSTRUCTION. 2. ALL FILL MATERIALS TO BE USED FOR THE DAM EMBANKMENT SHALL BE TAKEN FROM BORROW AREAS APPROVED BY THE ON-SITE GEOTECHNICAL ENGINEER. THE FILL MATERIAL SHALL BE FREE FROM ROOTS, STUMPS, WOOD, STONES GREATER THAN 6", AND FROZEN OR OTHER OBJECTIONABLE MATERIAL. THE FOLLOWING SOIL TYPES ARE SUITABLE FOR USE AS FILL WITHIN THE DAM EMBANKMENT AND KEY TRENCH: ML AND CL. 3. FILL PLACEMENT FOR THE EMBANKMENT SHALL NOT EXCEED A MAXIMUM 8" LIFT (UNCOMPACTED). EACH LIFT SHALL BE CONTINUOUS FOR THE ENTIRE LENGTH OF EMBANKMENT. BEFORE PLACEMENT OF FILL FOR THE BERM SECTION, ALL UNSUITABLE MATERIAL SHALL BE REMOVED AND THE SURFACE PROPERLY PREPARED FOR FILL PLACEMENT. FILL MATERIAL ADJACENT TO ALL SPILLWAY AND DRAINAGE STRUCTURES SHALL BE PLACED IN 4 -INCH (UNCOMPACTED) LIFTS AND HAND -COMPACTED TO THE SAME COMPACTION AND MOISTURE REQUIREMENTS AS THE ENTIRE EMBANKMENT. 4. ALL FILL SOILS USED IN THE EMBANKMENT CONSTRUCTION SHALL BE COMPACTED TO AT LEAST 95% OF THE STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM -698). THE FILL SOILS SHALL BE COMPACTED AT A MOISTURE CONTENT WITHIN -1 TO +3 PERCENT OF ITS OPTIMUM MOISTURE CONTENT. COMPACTION TESTS SHALL BE PERFORMED BY THE ON-SITE GEOTECHNICAL ENGINEER DURING CONSTRUCTION TO VERIFY THAT THE PROPER COMPACTION LEVEL HAS BEEN REACHED. THE FILL SHOULD BE COMPACTED USING A SHEEPSFOOT TYPE COMPACTOR. IN ORDER TO PREVENT DAMAGE TO THE PIPE, NO COMPACTION EQUIPMENT SHALL CROSS ANY PIPE UNTIL MINIMUM COVER IS ESTABLISHED ALONG THE PIPE. 5. THE DESIGN ENGINEER SHALL BE PROVIDED WITH REPORTS AND CERTIFICATION, BY THE ON-SITE GEOTECHNICAL ENGINEER, THAT THE GEOTECHNICAL ASPECTS OF THE FACILITY HAVE BEEN CONSTRUCTED PER PLAN. THESE REPORTS AND CERTIFICATION WILL BE NEEDED DURING THE AS -BUILT CERTIFICATION PROCESS FOR THIS STORMWATER FACILITY. THEREFORE, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE TESTING AND OBSERVATION WITH THE ON-SITE GEOTECHNICAL ENGINEER. 6. TESTING OF THE NEW FILL MATERIALS SHALL BE PERFORMED TO VERIFY THAT THE RECOMMENDED LEVEL OF COMPACTION IS ACHIEVED DURING CONSTRUCTION. THEREFORE, ONE DENSITY TEST SHALL BE PERFORMED FOR EVERY 2,500 SQUARE FEET OF AREA FOR EVERY LIFT OF FILL OR AS RECOMMENDED BY THE ON-SITE GEOTECHNICAL ENGINEER. 7. TESTING WILL BE REQUIRED ALONG THE 24"O RCP OUTLET BARREL AT A FREQUENCY OF ONE TEST PER 25 LF OF PIPE PER VERTICAL FOOT OF FILL OR AS DIRECTED BY THE ON-SITE GEOTECHNICAL ENGINEER. STATEMENT OF RESPONSIBILITY 1. ALL REQUIRED MAINTENANCE AND INSPECTIONS OF THE STORMWATER MANAGEMENT FACILITIES SHALL BE THE RESPONSIBILITY OF THE OWNER, PER THE EXECUTED OPERATION AND MAINTENANCE AGREEMENT FOR THIS FACILITY. CONSTRUCTION SEQUENCE 1. PRIOR TO CONSTRUCTION, THE OWNER SHALL OBTAIN A LAND DISTURBING (GRADING) PERMIT AND AN "APPROVAL TO CONSTRUCT" FROM THE TOWN OF TROUTMAN AND ALL OTHER NECESSARY PERMITS FROM APPLICABLE AGENCIES (E.G. 404 / 401 PERMITS) 2. INSTALL ALL SEDIMENT AND EROSION CONTROL MEASURES PER THE APPROVED SEDIMENT AND EROSION CONTROL PLAN. THE CONTRACTOR SHALL MAINTAIN ALL APPROVED SEDIMENT AND EROSION CONTROL MEASURES THROUGHOUT THE ENTIRE PROJECT, AS REQUIRED. THE CONTRACTOR SHALL RECEIVE APPROVAL FROM THE EROSION CONTROL INSPECTOR, AS REQUIRED BY GOVERNING AGENCIES, PRIOR TO ANY CLEARING. 3. CLEAR AND GRUB AREA WITHIN THE LIMITS OF THE PROPOSED DAM CONSTRUCTION. ALL TREES AND THEIR ENTIRE ROOT SYSTEMS MUST BE REMOVED FROM THE DAM FOOTPRINT AREA AND BACKFILLED WITH SUITABLE SOIL MATERIAL. THE BACKFILLED AREAS SHALL BE COMPACTED TO THE SAME STANDARDS AS THE DAM EMBANKMENT. THE REMAINING AREA OF THE EMBANKMENT SHALL BE STRIPPED TO A SUITABLE DEPTH AS DIRECTED BY THE ON-SITE GEOTECHNICAL ENGINEER. ANY RESIDUAL SOILS TO BE LEFT IN PLACE MUST BE WELL SCARIFIED TO PROMOTE BONDING OF THE NEW EMBANKMENT FILL. NO EMBANKMENT MATERIAL SHALL BE PLACED FOR THE DAM OR KEY TRENCH UNTIL APPROVAL OF THE DAM SUBGRADE /TRENCH IS OBTAINED FROM THE ON-SITE GEOTECHNICAL ENGINEER. 4. EXCAVATE FOR THE NEW KEY TRENCH ALONG THE CENTERLINE OF THE PROPOSED DAM EMBANKMENT. THE TRENCH SHALL EXTEND A MINIMUM OF 5 FT BELOW EXISTING GRADE OR 2 FT BELOW THE CONCRETE CRADLE AND SHALL HAVE A MINIMUM BOTTOM WIDTH OF 5 FEET. THE KEY TRENCH SIDESLOPES SHALL BE A MINIMUM OF 1:1 (H:V). THE KEY TRENCH SHALL BE COMPACTED TO THE SAME SPECIFICATION LISTED IN ITEM 4 OF THE SECTION TITLED "BERM AND SOIL COMPACTION SPECIFICATIONS." DEPENDING UPON ON-SITE SOIL CONDITIONS ENCOUNTERED DURING EXCAVATION, THE ON-SITE GEOTECHNICAL ENGINEER MAY VARY THE DEPTH AND DIMENSIONS OF THE KEY TRENCH AS DEEMED NECESSARY. THE ON-SITE GEOTECHNICAL ENGINEER SHALL RETAIN DOCUMENTATION OF ANY VARIATION FOR FUTURE AS -BUILT SUBMITTALS TO THE TOWN OF TROUTMAN. 5. BEGIN PLACEMENT OF BACKFILL WITHIN THE KEY TRENCH. THE KEY TRENCH SHALL BE COMPACTED TO THE SPECIFICATIONS LISTED ITEM 4 OF THE SECTION TITLED "BERM AND SOIL COMPACTION SPECIFICATIONS." THE KEY TRENCH SHALL BE TESTED PER THE SPECIFICATIONS LISTED IN THAT SECTION. 6. PRIOR TO INSTALLATION, SUBGRADE CONDITIONS ALONG THE SPILLWAY PIPES SHOULD BE EVALUATED BY THE ON-SITE GEOTECHNICAL ENGINEER TO ASSESS WHETHER SUITABLE BEARING CONDITIONS EXIST AT THE SUBGRADE LEVEL. SHOULD SOFT OR OTHERWISE UNSUITABLE CONDITIONS BE ENCOUNTERED ALONG THE PIPE ALIGNMENTS, THESE MATERIALS SHOULD BE UNDERCUT AS DIRECTED BY THE GEOTECHNICAL ENGINEER. THE UNDERCUT MATERIALS SHALL BE REPLACED WITH ADEQUATELY COMPACTED STRUCTURAL FILL, LEAN CONCRETE OR FLOWABLE FILL AS DIRECTED BY THE ON-SITE GEOTECHNICAL ENGINEER. 7. IN ORDER TO HELP PROTECT THE SOIL SUBGRADE FROM DETERIORATION (DUE TO EXPOSURE, RAINFALL, SEEPAGE, AND RUNOFF) BEFORE THE CRADLE CAN BE POURED, IT IS STRONGLY RECOMMENDED THAT A 3" TO 4" THICK CONCRETE MUD MAT BE POURED OVER THE SUBGRADE ONCE IT IS APPROVED BY THE ON-SITE GEOTECHNICAL ENGINEER. THE MUD MAT WILL ALSO PROVIDE BEARING FOR THE BLOCKS THAT TEMPORARILY SUPPORT THE SPILLWAY PIPE UNTIL THE CRADLE CAN BE POURED. THE METHOD OF BLOCK SUPPORT FOR THE PIPE PROPOSED BY THE CONTRACTOR SHOULD BE SUBMITTED TO THE JOHN R. McADAMS COMPANY FOR REVIEW. 8. BEGIN CONSTRUCTION OF THE NEW EMBANKMENT. FILL MATERIALS SHALL BE PLACED IN MAXIMUM 8" THICK LIFTS PRIOR TO COMPACTION, UNLESS DIRECTED OTHERWISE BY THE ON-SITE GEOTECHNICAL ENGINEER. FILL LIFTS SHALL BE CONTINUOUS OVER THE ENTIRE LENGTH OF FILL. IF IT IS NECESSARY, THE EMBANKMENT FILL MATERIAL WILL BE OVERBUILT IN HORIZONTAL LIFTS AND CUT BACK TO FINAL GRADE IN ORDER TO ACHIEVE PROPER COMPACTION. 9. AS CONSTRUCTION OF THE EMBANKMENT MOVES FORWARD, IT WILL BE NECESSARY TO INSTALL THE CONCRETE CRADLE. THIS MAY BE CONSTRUCTED USING ONE OF THE FOLLOWING METHODS: 9.1. IF THE PROPOSED STRUCTURAL FILL MATERIAL IS UTILIZED AS THE FORMWORK FOR THE CONCRETE CRADLE, THEN THE STRUCTURAL FILL SHOULD BE INSTALLED AND COMPACTED UP TO THE TOP OF CONCRETE CRADLE ELEVATION. ONCE THE STRUCTURAL FILL REACHES THE NEXT DOWNSTREAM JUNCTION BOX OR HEADWALL AND IS COMPACTED TO THE ELEVATION OF THE TOP OF THE CONCRETE CRADLE, EXCAVATE THE CONCRETE CRADLE TRENCH PER THE PROVIDED DETAILS AND CONSTRUCT THE CONCRETE CRADLE AS PER THE PROVIDED CONCRETE CRADLE DETAIL. 9.2. IF THE PROPOSED STRUCTURAL FILL IS NOT UTILIZED AS THE FORMWORK FOR THE CONCRETE CRADLE, THEN PRIOR TO CONSTRUCTING THE STRUCTURAL FILL EMBANKMENT, THE FORMWORK FOR THE CONCRETE CRADLE SHOULD BE INSTALLED ON EXISTING GROUND AND / OR THE MUD MAT. THE CONCRETE CRADLE SHALL BE CONSTRUCTED PER THE PROVIDED DETAILS. 10. INSTALL RISER / BARREL ASSEMBLY, ALONG WITH THE EMERGENCY DRAIN SYSTEM. THE DRAIN VALVE LOCATED WITHIN THE RISER BOX SHALL BE KEPT OPEN UNTIL AN AS -BUILT CERTIFICATION HAS BEEN COMPLETED BY THE ENGINEER AND AN APPROVAL TO IMPOUND HAS BEEN ISSUED BY ALL APPLICABLE AGENCIES. 11. INSTALL 24" RCP OUTLET BARREL SPILLWAY FILTER FROM THE DETAILS SHOWN ON SHEET SHEET SW -C4. 12. CONSTRUCT EMBANKMENT PER SPECIFICATIONS LISTED IN THE SECTION TITLED "BERM AND SOIL COMPACTION SPECIFICATIONS" AND REQUIREMENTS OF THE ON-SITE GEOTECHNICAL ENGINEER. ALL CHARACTERISTICS OF THE EMBANKMENT FILL MATERIAL SHALL MEET THE STANDARDS SET FORTH IN "BERM AND SOIL COMPACTION SPECIFICATIONS", INCLUDING COMPACTION AND MOISTURE REQUIREMENTS. IF NECESSARY TO ACHIEVE PROPER COMPACTION, THE EMBANKMENT FILL MATERIAL WILL BE OVERBUILT IN HORIZONTAL LIFTS AND CUT BACK TO PROPER FINAL GRADE. ANY HAND COMPACTION ACTIVITIES AROUND SPILLWAY OR DRAIN STRUCTURES SHALL BE CONDUCTED IN 4 -INCH LOOSE LIFTS AND BE TO THE SAME COMPACTION AND MOISTURE REQUIREMENTS AS THE ENTIRE EMBANKMENT. ALL COMPACTION AND MOISTURE TESTING SHALL BE CARRIED OUT AS DIRECTED BY THE ON-SITE GEOTECHNICAL ENGINEER AND AS LISTED IN THE SECTION TITLED "BERM AND SOIL COMPACTION SPECIFICATIONS". 13. UPON COMPLETION OF DAM EMBANKMENT, PROMPTLY STABILIZE AND SEED DAM EMBANKMENT PER SEEDING SCHEDULE. 14. SCHEDULE A FINAL AS -BUILT INSPECTION AND AS -BUILT SURVEY WITH THE ENGINEER. AN AS -BUILT INSPECTION SHOULD BE SCHEDULED A MINIMUM OF 60 DAYS BEFORE A PERMIT TO IMPOUND IS REQUIRED. ANY COMMENTS OR DEFICIENCIES IN THE DAM CONSTRUCTION MUST BE CORRECTED TO THE SATISFACTION OF THE ENGINEER AND OWNER BEFORE CERTIFICATION SHALL BE GRANTED. UPON FINAL APPROVAL FROM THE TOWN OF TROUTMAN, CLOSE THE 8"O BOTTOM DRAIN VALVE IN THE RISER BOX AND BEGIN IMPOUNDING WATER. NO WATER SHALL BE IMPOUNDED BEFORE AN APPROVAL TO IMPOUND IS ISSUED FROM THE TOWN OF TROUTMAN. OUTLET STRUCTURE MATERIAL SPECIFICATIONS 1. THE 24"0 RCP OUTLET BARREL SHALL BE CLASS III RCP, MODIFIED BELL AND SPIGOT, MEETING THE REQUIREMENTS OF ASTM C76 -LATEST. THE PIPES SHALL HAVE CONFINED O-RING RUBBER GASKET JOINTS MEETING ASTM C -443 -LATEST. THE PIPE JOINTS SHALL BE TYPE R-4. 2. THE STRUCTURAL DESIGN FOR THE 4'X 4' (INTERNAL DIMENSIONS) RISER BOX WITH EXTENDED BASE SHALL BE BY OTHERS. PRIOR TO ORDERING THE STRUCTURES, THE CONTRACTOR SHALL PROVIDE, TO THE DESIGN ENGINEER FOR REVIEW SHOP DRAWINGS AND SUPPORTING STRUCTURAL CALCULATIONS SEALED BY A P.E. REGISTERED IN NORTH CAROLINA DEMONSTRATING THE PERTINENT VERTICAL LOADS ARE SUPPORTED BY THE CONCRETE RISER STRUCTURE. 3. THE RISER BOX OUTLET STRUCTURE SHALL BE PROVIDED WITH STEPS 16" ON CENTER. STEPS SHALL BE PROVIDED ON THE INNER WALL OF THE RISER BOX. STEPS SHALL BE IN ACCORDANCE WITH NCDOT STD. 840.66. PLEASE REFER TO SHEET SW -C2 FOR LOCATION OF THE RISER STEPS. 4. THE CONCRETE ANTI -FLOTATION BLOCKS SHALL BE PRECAST AS THE EXTENDED BASE OF THE RISER BOX DURING FABRICATION. THE PRECAST BASE SHALL BE INCLUDED AS PART OF THE SHOP DRAWINGS THAT WILL BE SUBMITTED TO THE ENGINEER FOR REVIEW (SEE ITEM 2 ABOVE). IN LIEU OF A PRE -CAST BASE, THE CONTRACTOR MAY OPTTO CAST -IN-PLACE THE ANTI -FLOTATION BLOCK IN THE FIELD. HOWEVER, PRIOR TO CONSTRUCTING THE CAST -IN-PLACE BASE, THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE ENGINEER FOR REVIEW DENOTING THE FOLLOWING: A. STEEL REINFORCEMENT B. THE CONNECTION MECHANISM TO JOIN THE ANTI -FLOTATION BLOCK WITH THE RISER SECTION 5. IF THE ANTI -FLOTATION BLOCK IS PRECAST AS PART OF THE RISER BASE SECTION, THE ENTIRE PRECAST RISER BOX STRUCTURE SHALL HAVE A SHIPPING WEIGHT OF 25,116 LBS. THE STRUCTURE WEIGHT SHALL BE THE SHIPPING WEIGHT AND SHALL BE DETERMINED BY SUBTRACTING THE WEIGHT OF THE FACTORY BLOCK OUTS FROM THE GROSS STRUCTURE WEIGHT. THIS INFORMATION SHALL BE SHOWN ON THE SHOP DRAWINGS SUBMITTED TO THE ENGINEER FOR REVIEW, IF THE CONTRACTOR OPTS TO CAST -IN-PLACE THE ANTI -FLOTATION BLOCK, THE CONTRACTOR SHALL ENSURE THE WEIGHT OF THE ENTIRE RISER STRUCTURE IS EQUAL TO THE MINIMUM LISTED ABOVE. 6. THE RISER BOX JOINTS SHALL BE SEALED USING BUTYL RUBBER SEALANT CONFORMING TO ASTM -C990 -LATEST. IF NECESSARY, THE CONTRACTOR SHALL INCORPORATE A WATERSTOP INTO THE RISER BOX JOINT TO ENSURE A WATERTIGHT CONNECTION. THE CONTRACTOR SHALL PARGE JOINTS ON BOTH THE INSIDE AND OUTSIDE WITH NON -SHRINK GROUT. 7. PRIOR TO ORDERING, THE CONTRACTOR SHALL SUBMIT TRASH RACK SHOP DRAWINGS TO THE ENGINEER FOR REVIEW. CONTRACTOR SHALL ENSURE THAT AN ACCESS HATCH IS PROVIDED WITHIN THE TRASH RACK (SEE DETAIL FOR LOCATION) THAT WILL ALLOW FOR FUTURE MAINTENANCE ACCESS. CONTRACTOR SHALL ALSO PROVIDE A CHAIN AND LOCK FOR SECURING THE ACCESS HATCH. NOTE THE ACCESS HATCH SHALL LINE UP WITH THE ACCESS STEPS AFTER INSTALLATION. 8. ALL POURED CONCRETE SHALL MEET THE FOLLOWING SPECIFICATIONS UNLESS OTHERWISE NOTED: -MINIMUM 3000 PSI (28 DAY) -SLUMP = 3" - 5" -ENTRAINED AIR = 5% - 7% PLEASE NOTE NO CONCRETE SHALL BE POURED WHEN THE AMBIENT AIR TEMPERATURES ARE EXPECTED TO BE ABOVE 85°F OR BELOW 40°F. CAST -IN-PLACE CONCRETE SHALL BE "WET CURED" AFTER FINISHING FOR A MINIMUM OF 48 HOURS. 9. GEOTEXTILE FABRIC FOR THE 24"O RCP OUTLET BARREL JOINTS SHALL BE MIRAFI 18ON OR ENGINEER APPROVED EQUAL (NON -WOVEN FABRIC) 10. STORMWATER FACILITY EMERGENCY DRAW DOWN IS VIA AN 8"O PLUG VALVE. THE VALVE SHALL BE A M&H STYLE 1820 X -CENTRIC VALVE OR APPROVED EQUAL. THIS VALVE IS IN ACCORDANCE WITH AWWA C-517, AND SHALL BE OPERABLE FROM TOP OF OUTLET STRUCTURE VIA A HAND WHEEL (SEE DETAIL SHEET SW -C3). THE CONTRACTOR SHALL PROVIDE A REMOVABLE VALVE WRENCH WITH A HAND WHEEL ON TOP FOR OPERATION OF THE 8"0 PLUG VALVE. A CHAIN AND LOCK SHALL ALSO BE PROVIDED FOR SECURING THE WRENCH TO THE TRASH RACK. //-,\ v : y �� � I I 1� - - I I I I I I I l I � I• / /I III � I I I I I' 1 / I I / / // I 1, / / \ h 11 I I III / // I / // I\ I I I II I I I I I / // / / / / / / / / / / I � � \� I I IIII//1 11 l/ I S I I I I I I I I I I I/ l// , I l l / / l l / �_ � � � I I 1 III `\ \\ � I I I I I � -->� � � \�� �� I \ 1 IIII\\\ \\ \ t\ V I I I /I I I I I ,� I \ I I I I / � � �/ � � � / � I \ I III 1\\ \111 \ \ � � I III I I I I I ' I l �--; � \ : /1_� /� ) I I III\\\ I\ \ I IIII I I I I I � �� � / / I\ \ \I I \\II II I\ \ V I I I I I I I I I I - -� )� /� / `i 11\ III I \ I \ I I I I) III I I 1 1 I �\ � 1A � I % / � /\, ) \I 1 I \\ III I I \ \ I I III I I I I 1 I - � � � � � / '' / � /� , I I I I I I \ I I I � I I`I I I I I 1 �� � � // � /� �/ / IIIIII II \ \ \ I I// / // 1 I I / I I / /� � \ / / / I I ��/// ////, I y I �l �////// l/ l/ 1/ - //� : \\ - / / / \/ / / / / / / ' \I I I/ / /////C3 1'1/ // / I/ / // // / \ EX. WETLAND \ / / / / / / co / / � �- / � \ � / / / I I / I &I I / // /I / I / / / / / / / / I SEWER EASEMENT I I 1 I I / ' / I I I /' ' I I / / / / ( �i- - �� � � I� : 1 \ I I I / V I I I I I i t /I I I I IIII 1 l /l /' l l' � c / / � I I I I / / I I I I/ I I I I I I I I/ I/ / 1// // � / / � � - -\ 1� III \ \ I / I I I I I I IIII/III // / / / / / / l -� \\ I\\\ I/ I I� I /I III I I I/ I, 1/ � � ��/ � __-� ) v4v I� 1 I 1\ I I/ I/, I I'T 1 1 1 I I I I I I I I /� II j I I I I � \� � \ \I I I I I/ /// // /I I I i I I III I I I' l /l I I I '' l ,� '�l � �/ �) I//////// I I II �I II/ I/ / / I 4 � 1 � \ \_ � / SII / / / / I / I �1 I / /l // , /l /l / / I I / 1 1 l I I I I �� l 1 � \ l \ l 11////// / / I ' 1, 'llll '/ 111/' I , I I � � \ � �/ I I I I I I I /I I/ /// l/ l/ l 1 1 1 I I/ )4 �/ I 4\ � � I � I I I I I I 1 / III // ///// //// / I I I / 4 � \� � I� I I I I I I I I / I I I/ IIII Il ,/ // / I I I I I /� I �\ � � 1 S I I ( I I I I) I/' / / I/ I I /// /// l/ l I I I I I/ l � //I � \I � � \� I I I I I' ''' I � I' I �' l 1il Il1// I III I�� �l IIII/I l I 11I, I1' I � / I � \ � � / , ' / / / / / // I I / I I , INV = 854.00 ' I / / l ) lI I I lI I I I I �� �l / �� �\, � / � , / /, 1, l/l // I I l r II 1, I I , I // 1__/ � * � \ / // l l / l // � , I/ /'''/III 'IIIIII I � �// � /� / � / /��/l/llll/l 1 ////I// IIIIIIIIIIII II � : //��//I /- /// //l/l 11/l I§ , 'll /�lll�'I I' I ' I I ' � / I � I � � /� �� I /� � // / /'/' l/'/'� l / /)l/ �/' l / / 11 I I I I / � I I � � � /�I �__��� l/// /,l/l/// l l l/////////,l,',I�II II ,�� � / 4 � J ,4) // / // / // // / / /// / // //'//// / / /// / 1 , I I � I/ � /� r / / / / / / / l //� � / / / l /l/ l l /// / / I I I I I I / II I II �/ I� 4 / / /// // // �' I /I I l' l/ // ////// l/ l I I I I 14 1 I I � I � I �� - // / / ,-- / // / / / // // /// // / � �� / // / /' / / / // , / I I I I I I I I� I I/ / / / / // / I/ � // // � /11 / / / I I I III AOR I: �) / I ,/ I/ / / / ,� , // / , I I / / / / / // STORMWATER CONTROL / / 1 1 I I I I I �)I I � / I I / / / / / / / /�/ MEASURE MAINTENANCE / / / I I 1 I I II / � 1 � / I I / / / / /// / /// / /ACCESS EASEMENT / / / / I I I \ \ \ I\ / 4 l 4l I '`/ / / // //,1 / / / II/�,�//// I I I I I \ \ \ I I \\\ _ / � � / I / / / / /// / / / / 11 //I' / I I 1\ 1 \ \ \ �\ \� / �/ / I // / / // / / / / /// I / /I j I 1 II I I I � � A, v /vv j j v � / l I / l 1 1/ll / t? / �I I I v �o - A �� / / / / / / / / / / / / / / �/ I I / / ' I I \ 1 II A -� \ � A \ I I\+853.7 V / / / / / / / / / / ENDWALL PER I I I I I \ / z/ 3: 1 IV I 1 / // I / // /' / / /' I I ( I / , NCDOT STD. 838.80 1 I I I / l / pa /SLOPE �' I//// // / / � \ / / / I I I I I INV. OUT (24.0 RCP) = 850.00 / / I I / / / /� g/ /� � / /853 � - - � 1V I / / �' / / I / I I I / - ' I / '/ / 1 I I I / / // o� / C', Ni / /+ / \ I / / I I I I I I VELOCITY DISSIPATOR' / / / / I / ' / // // / / m"����\ / / V \ 1 / / I I I I NCDOT CLASS 'C' RIPRAP / I I / / / / / 0-,2/ / V V / / ) \ I I I I I / I 12'L X 6'W X 22" THICK ,% / I I / / / / /' // I-/ / / / j �/ /+� 75 - I / I I I� D50 = 8" �l I / / / / / / / / / / f - - oo / �� / I I I I 1 (SEE DETAIL SHEET SW -C4) / I / / / / / / / / / / // -_ g5h' �,/ / I I ° / I I // I I I I // / / / / // / / / // �/ io - 1-1 ,�, I__ � // I / I I I I I / ° l I I I/1 ///////// /// / / /// /, 11 - �----� / I / ) / / I I I / / / / / / / / / A +853.50 / - / / I / / // / / /'// / / / / // / / / / / / / �/ // / // / / VA1 / / I I I I l / / / /// J/l� 1 // / l l l l /I l / � l/ / �/ \I\\ / I / I / // //� / / /// //// / /// // I / / / / / / / / / / • / / / / / // / .L , /\ / \ I I ( I i / // I / l l l / l / / / l / / / / /l / / / / l l / / /l // / / )/l / A /\ I I \ CONTRACTOR SHALL LINE OUTLET / , / / / / / // / / / / / / / / / / / / A �// / / � � V A ) \ CHANNEL WITH NCDOT CLASS 'B' RIPRAP. I / / // / / / / / / / / / / / / / / / / I / �/� J( \ \\ / \ THERE SHALL BE NO DISTURBANCE TO / / / / / / / / / / MI�CROI II VA V / ANY EXISTING CHANNEL BANk. A FILTER 1 I / I / / / / / / / l l l / l �/ POOL \ / A BLANKET SHOULD BE INSTALLED BETWEEN / / / / / / / / / / / / � / / / / / / / / I I / / � / I \ \ \ ° / I RIPRAP & SOIL FOUNDATION. FILTER / / / // / „ / BLANKET SHALL CONSIST OF A MINIMUM / % / / / / 57 LF 24 CLASS III / / / / / I / ,� \I \ \\___�- 14" THICK LAYER OF NCDOT #57 STONE /, / / / / / / / / 0 -RING RCP ® 1.75 / / / / \/ < _//8 �,L \ \ \ I UNDERDRAIN WITH MIRAFI FILER WEAVE // / / I // / / W/ CONCRETE CRADLE / / \ 0 / V � V A I 700 OR APPROVED EQUIVALENT. / ' / I // /// / / (JOINTS WRAPPED IN / / / I / I / /- g�I \ I / i I i / l L? / �� EOE TI E F BRC / l / I ��I__L_ . I- ) 1 I / / \ / / / /�/ / / / / /// / / / / //,/ /� , / c x L A I ) / / / / I I 8S31.so 1k. , / e I /11 ' I Ill/ / / / // / / / // / / / l/// / / /r/ ,// / / l l l / / / I/ I / / / $6/ /$� I / / I I // / � �_� / // / / / / / / ///� PRECAST RISER OUTLET STRUCTURE \ / g0 / / / / / I v / / / e / SHAPE =SQUARE v / // I I / / v / ) I / r / / / / / / // INTERNAL DIMENSIONS = 4 FT. x 4 FT. / / / / �( -� / / / I \ \ I / // / / / / TOP OF RISER = 858.50 / / / I / \\\ \ \ I / / / / / / / / / / I / // " 1.0"0 ORIFICE = 855.25, / / / I 1 I / I / I I l \ - -- \ / / / / / / / L7 // 1.5 O ORIFICE ((INVERTED SIPHON) = 854.00 I / / / / / / ' / / \ �� � I / / / / / / / I � / // /, INVERT OUT (24"41 0 -RING RCP) = 851.00 / I / / / / I � / / V / \ � \ \ \ TOP OF BANK (TYP.)� / / / / / / // (SEE DETAIL ON SHEET SW -C3) / / I / / Jl �' / / / \ /-� �� vv v\ I I /' // // // / // / / // / //// / // / / /" / / // I / / / / I <o:� 11 / I / / / \\ \\ \\ \ I / / / / / // / / / / / / lt? /// / /, / / / / / / / / / / / / / / I � I / I ' / \ \ \\ V / / / / / / � / / / / / / / / / / / / / / / / I i I / / \ � / \ `\ \\ \� �\ \ / / / , / / �,/ / // / //i / /\ / /// / / / / / / / /, / / / / / / / / I 1 / ! / I I ) \ I \ \ \\ \ \\ \ / // / / / // ////�/ /// /�/ / / / / // / / / / / / / / I I \ / / \ 1 I \ \ \ \ 1 I / / / / // / / / / / / 17 1 // // / / / / / / / / / / / / / / / / i / / / / / / / I \ I I I / // / / /� / / / / / / / // // // / / / / / / i / / / / / / I / I / / // / / / STORMWATER CONTROL MEASURE, ) I A / / / / /' l/ ) / / / / I l / / / / / / / l/ / 17 / / /// // / / / MAINTENANCE/ACCESS EASEMENT / / / / / / / / / I �� / / I I I \ / ////�/ / /' / l I II I l I l �// / / / ////// //l / / / / / /I � / / / // / /' / / / l I I I/ I I I /x 11 �_, / /// / / I I I I I I I I / ��/ /�// ///// / / / / / / / / / / / / ' / / / / / / I / �� / / I \ // / �� / / / I II I I / g / // // // / / / / / / / / / / I I i / / ��� �/// I I I 1 I I 1 1 I I / /// //// / / / / / / ' / / / ' / / \ i I / I I 1 I I / \ /ry / ' / / / I I I I I / /// / / / / / / / / / / / / / / I ) /I//I / // I // \�--- / I III I I I I I / / / // / / // / / / / / / ' I I / / / ' / / / l I I I / / I I / / /,/� -/ ' ' ' ' I I I I III I// � //// //// / / / / / / / / / / I / / / / / / / / / / / / / / / / / I I //I -/ �, // J , / / I I III IIII I / / '/'/ / //' / / / / / / / I I ' � ' / / / / / / / / / / / / / / / / //� /�//II�j,/ /�///////////// /',)////// '' /// I / / / / /) IIII/ I,/ / // //// / / ' / / / / / / / / / / / / / I //� \ \ l I ) Il I II I11 I I 'l / 1 I / ' l l / / ' l � / I l l l / / / / � \_ ///I \ l l l ' / / / l l / /l1 / ' / l y / / / / / / / / / / / p / / I �°j / / / / / / / \ PROPERTY LINE / // i" / / / /// // / I/ // I/ I / / / / / / / / / / / / / / / / , CO / / / , / I 1 I /I � � /'//' I /' I / ' / / / // / / /�, / / I I / / / / / I I / / / / / / / I / / / / / // / / / / / / / / p // /J \ �' � �/ l / I l / / / /// / l l / l )/ l / Ill I l / l l l 1 / I I I I l l l I I w / / \ // \__- , �� \ ' �S' I I 1 'I /'////�//� '////'/'l / ' / / / / / ' I I I / / / / / / ' / / I / I 1 // / // /� / ' I I I I / /// / // jq0� / // / �/ l / / 1 / I I I 1 1 I / / / / / / / 1 I \ 1 / / /�//j I / / / I I I / I //// / t / / l // / / / /// / l / / / / I I I I I l / , l / / l / / l / / / / / \ I// -_ // /// I // / // I I/// // / r/ // 1 1 1 I I 1 1 1 l I ) I I I I I l l l /l // I /% /-// /"% �1I // ,,_/ // /r / / / / / / / / / / I /_ / � / / / I I / / / / / / / I / / / / / / / I / / / / / / / -/ / / / \�' / / I it ////// /,t? / l/J) 1/ l / / / l / I I I I , ' / l ' l l l / // /-/ l� / --///� / / /// // / /// / / //// /- / / / / / I / / / / / / /I- �� /, ////' / I / / / / / / // /// / / / / / , / / / / / / / / / / / � %/ / �' _ / �/% I / � �885� - / I II ' l l l / / 1 / 25' PERIMETER BUFFER / / / / / I / / \ �', // /// / L? ///// / / / / / / / / / / / / / / / / / / / / / / /�// // I/ l / �/ //� �l /114 � � �/ fi / l V I /// / / // / / / / / / / / / / / / / / / //// � L � / // X / ,/ I ///// / / / / / / / / / / \ -/ I / v // A / /� / / / / / / / / / / / ' / / / / / "/ // V -�� /// / I I GRAPHIC SCALE L? ' // / / / / / / / / / / / / / ' / / / / / C / / / // / \ \� 0 10 20 40 / � l l , it / / / / / l i / � / 7 / , / / /� - � // I k \- \ i STORMWATER CONTROL MEASURE 'C' PLAN VIEW 1 inch = 20 ft. 1" = 20' FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER L/) 0 k.D (.0 z�__00 Ou RYN17010-SWC LU JAA W �N W z z m Q Of z = � J U; 0 L/)or = �iC z``'U �-- O O = or_ Ou RYN17010-SWC JAA CC Z) 0 z z m � qzj- 2 V) i ^ Z W = O �-- U REVISIONS N0. DATE PLAN INFORMATION PROJECT NO. RYN-17010 FILENAME RYN17010-SWC CHECKED BY JAA DRAWN BY JSM/LK SCALE 1" = 20' DATE 11. 26. 2018 SHEET STORMWATER CONTROL MEASURE 'C' PLAN VIEW sw-ci TOP OF DAM EL. = 860.00 100 -YEAR STORM EL. = 858.92 10 -YEAR STORM EL. = 858.53 TOP OF RISER EL. = 858.50 W Q 2 -YEAR STORM EL. = 856.99 IWQV STORM EL. = 855.26 NORMAL WATER SURFACE EL. (NWSE) = 854.00 24"0 RCP INV. OUT EL. = 851.00 CONCRETE J ANTI -FLOTATION BLOCK 8"0 EMERGENCY DIP DRAIN WITH TRASH RACK (SEE DETAIL SHEET SW -C3) WIM APPROXIMATE LOCATION OF EXISTING GROUND COMPACTED BERM SECTION �► (SEE BERM AND SOIL COMPACTION TOP OF HANDWIHEEL TO EXTEND SPECIFICATIONS ON SHEET SW -C1) 1 -FOOT ABOVE TRASH RACK TRASH RACK 10 FT. WIDE MINIMUM (SEE DETAIL) PROPOSED GRADE 1.0"0 ORIFICE M-1 I I -I I -I I -III -III -I I I -I I I= INV. = 855.30 =III=III=1 I=III III=III=III=III=III=III=I I I___E ,- _- I=IIII I I=1 I I=I I I=I I I=I I=I I I=I I I=III=III=I 1-11 I=I I I=I i MI I1! 1 3 SIPHON w/ 1.5"0 DRILLED ORIFICE 1► I=I I I=I I I=I I I ==I I I=I II=I I I=I I I I I I=1 I I=III=1 I I=1 I I=I I I=I I I=1 II=I 1 1EI I h11 (SEE DETA L) _- I I I=III=III=1 I I=III=III=III=III=1 1=III=III=III=III=III=III=III=III=III=III=III _- CONCRETE COLLAR _ I -I I I -I I I -I I I -I I I -I 11=1 �, II-III=III-III-III-III-III-I I I -I I NEI I I -I I I I- I (TO BE CONSTRUCTED IN = 1=III=III=III=1 I I, I 1=III=1 I- 1=1 I=I I I_01 (MIN) I I=III=III=III=III=III=III=III=III=III I=I I=III='11'x,, THE FIELD BY THE _- I=1 I I=I I Ed I I=III=I I i =I "I I I=I I I=1 I I=I I I=I I I=III=I I I I=I I=I I I=I I I=I I I=I 11=1 I I=I I I=I I I=I I I I I=I I=I I=I I I=111� CONTRACTOR, SEE DETAIL) 1=III=III=1 I I=1 I I=I I I=III=I 11-' 1 I EI I I=I I I=I I I=I I I=III=I I=I I I=I I I=I I I=I I I=I I I=I I I=I I I=I i I=I I I_ r I=I I FE1 I I=I 11=1 I I=I 1 I�1' I� I I -I I I -III -I I -I i -I I -I I -I I -I I -I I I I -I I i -I I I -i I I -I 11-11 I I 1 I-1 I I -I I -I I -I I -I I -I I -I I- EEEI � I I -I I -I 11-I I IEEEI I -I I I -I I I -I I I-III-n,� 2" COVER (MIN.) -- I -I I I=I 11=I I F1 I I=I I I=I I I=III=III=I I I_= 1 I I=1 I I I I EI I I=I i I=I I=1 11= I=1 I I=I 11=I 1=I 11=I 1 I=I I=I 11=i 1 1=1 I=I I=III=I 1=1 I=i 1=I 11=1 I=I 11=1 I �� - -- _=III= I I I7 I I I_ I I I- I I=11 1-1 I -I I -I I I I 1-I I I -I I I -I I I -I I I -I I I -I I I -I I I -i I I -I I-1 1-1 I I -I I -III -I I-1 I -I I -III -I i l l777 --------------- ---- 0 1 -- FLOW -�` 57 LF CLASS III 24"s� 0 -RING RCP (ASTM C76 -LATEST) ®1.75 - - - - - -' - - - - - - - - - - - - - - - - - - a 4 d a -- a a d d 4 - -d - -�-d - d -'--.d -- .,p ---Z-- -- a -d- ----d-4 .- -- --- -a ----° ---°=4-od � - ° .4\\/\/\/\/\/\/\ \ \ v\ \ \ \ \ a ° ° 4 o 0 \\\,\\,\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ \ \ \ \ \ \ \ \\\\\ 24"0 CLASS III 0 -RING RCP'\/ \/ \/ \/ \/\//\//\//\//\//\//\//\//\//\//\//\\//\//\//\ I -I (I 12.0 (MIN) // // // // // // // // // �/ // // %/ // / / / / / / \\/INV. - 851.00 \ �\ �\ �\ �\ X\ X/\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \ III \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ \\\\\\\\\\\\\\\\\\\�\\\\\\\\ // // // // // // // // //// // // \\\\\\\\\\\\\ \\\ /\ /\ \\\ \\\/ 5 FT. WIDE MINIMUM \\\\\\\\\\\\\\\\\\\\\\\\ /// /// /// / /// // // �/ �/ �/ �/ �/ /// /// /// /// /// /// /// /// /// /// /// /// /// /// /// / \CONCRETE . \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ CRADLE //\/ (SEE DETAIL ON SHEET SW -C4) i KEY TRENCH (SEE BERM AND SOIL COMPACTION\\\\\�\\�\\�\\�\\�\\�\\�\\\\\\\\\\ \\\\\\\\\\\\\\\\\ \ CONTRACTOR SHALL FORM INVERT OF RISER STRUCTURE TO DRAIN POSITIVELY SPECIFICATIONS, DETAIL SHEET SW -C1) TO INVERT OF OUTLET BARREL USING KEY TRENCH TO BE PROVIDED PER THE A DOUBLE LAYER OF NON -WOVEN NON -SHRINK GROUT DIRECTION OF THE SITE GEOTECHNICAL ENGINEER GEOTEXTILE FABRIC SHALL BE PLACED AROUND EACH JOINT OF EACH 24"0 0 -RING RCP BARREL IN 2' WIDE STRIPS CENTERED ON JOINT. PERMANENT DAM CROSS SECTION N.T.S. -I 11 113 I S�OpF WQV WATER SURFACE EL. = 855.26 V 7 15" MAXIMUM PONDING NORMAL POOL EL. = 854.00 0 -IIII - I _-III I- i FOREBAY MICRO POOL 2.5' DEPTH - 2,5 DEPTH _ I I 1 I- I I I I I I I III ,E - 1 3-1 I I I -i I III i I II I I I I I I� I I -E 31 i I- II I I II -III I I 1 i- I I I I ► ►-� I ► I _ I I II l I� ► ► ► ► ►� _III-► ► II ► I -I _ i I ► ► I _III I_► ► I_ II I -III I Ii I II II I IIII II BOTTOM EL. = 851.00 11=IIII I- I - I I I I -I I -I I - I I- II I IIII I =BOTTOM EL. = 851.00 = 1-I I I I iI i I IIIA I -I I._I I I I II I- I- -11 I I II I IIII i I -I I I I I II _III -I 111 I VIII I II I I I I- I I-1111 I I -III _ I 1I I I I I I I I I I I I 6" MINIMUM I -I -I -III- I -I I I I I I I I -I I I- 6" MINIMUM III- SEDIMENT STORAGE- SEDIMENT STORAGE - =1 II i 1=-1 I I I I I1 1 11 1 11 II I I I I-1 - 1 I I I 1 I �� ►� 1 11 I- I Ed I F1 EIII I X1-1 �111,�1 Ii, 11= 1 I =III=11= 1= I 1=III I ,il-ll�,lI[-=I 1 � I�wE1 I�111�1 �I�I �Iii►IIII�I-1►�I� I�IIIII�IIIII�11111M = 1=II 1 I -I SII= I .. I1 � II ILII I1 = , �� � -1 1 H - CONCRETE ANCHOR ^^'T (TYP., SEE NOTE # NOTES: 1. REMOVED TOPSOIL SHALL BE STOCKPILED FOR USE IN PLANTING (SEEDING) THE DAM EMBANKMENT ONCE FINAL GRADES (AS SHOWN ON THE GRADING PLAN) HAVE BEEN ESTABLISHED WITH COMPACTED FILL. PRIOR TO TOPSOIL INSTALLATION, THE CONTRACTOR SHALL SCARIFY THE TOP 2- TO 3 -INCHES OF THE BERMN SECTION TO PROMOTE BONDING OF THE TOPSOIL WITH THE COMPACTED FILL. THE TOPSOIL DEPTH SHALL RANGE FROM 3- TO 4 -INCHES ON THE DAM EMBANKMENT. ENDWALL PER NCDOT STD. 838.80 (SEE DETAIL ON SHEET SW -C3) LOCITY DISSIPATOR CDOT CLASS 'C' RIPRAP MINIMUM DIMENSIONS 121 X 6'W X 22" THICK D50 = 6" TO BE LINED WITH GEOTEXTILE FABRIC OR EQUIVALENT (SEE DETAIL SHEET SW -C4) 24" CLASS III ' \\O-RING RCP / INVERT EL. = 850.00' SPILLWAY FILTER (SEE DETAIL SHEET SW -C4) 7.0' 1.0' (TYP.) I 0 9.9 LF -� 2"x2"x1 /4" ANGLE THE BOLD / DASHED LINETYPE DENOTES THE ACCESS HATCH TO BE PROVIDED BY THE TRASH RACK FABRICATOR PER OUTLET STRUCTURE MATERIAL SPECIFICATIONS (SHEET SW -C1) 9.9 LF 2"x2"x1/4" ANGLE 9.9 LF 2"x2"x1/4" ANGLE 2.0' 4" PVC CAI SCREW TYPE TOP EL. = 855.00 INVERT THROUGH RISER EL. = 854.00 NOTES: d 1. ALL REBAR TO BE #4 REBAR. CONCRETE 2. ALL REBAR AND ANGLES TO BE HOT -DIPPED GALVANIZED AND BE PROVIDED ANCHOR BOLT WITH AN EPDXY COATING. BOTTOM EL. = 853.50 (TYP., SEE 3. THE HOT-DIPPIED, GALVANIZED 2"x2"x1/4" ANGLES SHALL BE WELDED TO THE NOTE #4) REBAR TRASH RACK. ONCE WELDED, THE ENTIRE ASSEMBLY SHALL BE PLACED ONTO THE RISER WITH ANGLES SITTING DIRECTLY ON TOP OF RISER. 4. CONTRACTOR SHALL ANCHOR THE TRASH RACK TO MANHOLE WALL WITH FOUR 4"x1/4" CONCRETE ANCHOR BOLTS THROUGH ANGLES. 5. CONTRACTOR SHALL OMIT OR ADJUST REBAR AS NECESSARY TO ALLOW FOR 4" PVC CAP WITH CONCRETE COLLAR. 1.5"0 DRILLED ORIFICE FABRICATED HINGES FOR THE 6. ACCESS HATCH SHALL ALIGN WITH STEPS IN RISER. 2'x3' ACCESS HATCH. ACCESS HATCH SHALL BE POSITIONED OVER STEPS. RISER TRASH RACK DETAIL WETLAND CROSS SECTION N.T.S. SIPHON OUTLET DETAIL N.T.S. N.T.S. RISER OUTLET STRUCTURE n 4 d 2� _ 4"0 PVC SIPHON INVERT EL. = 854.00 (NWSE) n NOTES: 1. ALL REBAR TO BE #4 REBAR. 3" CLEARANCE - TO OUTSIDE OF #4 REBAR) 3.625' 0.5' ANCHOR DEPTH 5.0' 3" CLEARANCE TO OUTSIDE OF #4 REBAR) ° d d a a d - / 24" 0 -RING ` RCP f 4 4" 3.8' 4" (CENTER TO (CENTER TO (CENTER CENTER) CENTER) CENTEF FRONT VIEW 3" ANCHOR DEPTH 3" CLEARANCE TO OUTSIDE OF #4 REBAR) PRECAST STRUCTURE WALL #4 REBAR ANCHORS. - CONTRACTOR SHALL DRILL INTO PRECAST STRUCTURE WALL AND 3.83' SET ANCHORS USING EPDXY GROUT 4 A 6 d S" CLEARANCE FO OUTSIDE OF �4 REBAR) ANTI -FLOTATION BLOCK CONCRETE COLLAR DETAIL 1' DEPTH 3000 PSI CONCRETE COLLAR (MIN. 28 DAY STRENGTH) 3" CLEARANCE TO OUTSIDE OF #4 REBAR) 24" 0 -RING RCP 6" ANCHOR DEPTH d SIDE VIEW 5.5" CENTER TO CENTER #4 REBAR ANCHORS. CONTRACTOR SHALL DRILL INTO PRECAST BASE AND SET ANCHORS USING EPDXY GROUT CONCRETE ANTI -FLOTATION BLOCK FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION l€GADAN�� The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER (V // V Z 00 RYN-17010 FILENAME RYN17010-SWC W�wN d. W Q SCALE Q � z 4 V d a 4 Q Z d d O �0° DG � LU 7 m U_ a 4" 3.8' 4" (CENTER TO (CENTER TO (CENTER CENTER) CENTER) CENTEF FRONT VIEW 3" ANCHOR DEPTH 3" CLEARANCE TO OUTSIDE OF #4 REBAR) PRECAST STRUCTURE WALL #4 REBAR ANCHORS. - CONTRACTOR SHALL DRILL INTO PRECAST STRUCTURE WALL AND 3.83' SET ANCHORS USING EPDXY GROUT 4 A 6 d S" CLEARANCE FO OUTSIDE OF �4 REBAR) ANTI -FLOTATION BLOCK CONCRETE COLLAR DETAIL 1' DEPTH 3000 PSI CONCRETE COLLAR (MIN. 28 DAY STRENGTH) 3" CLEARANCE TO OUTSIDE OF #4 REBAR) 24" 0 -RING RCP 6" ANCHOR DEPTH d SIDE VIEW 5.5" CENTER TO CENTER #4 REBAR ANCHORS. CONTRACTOR SHALL DRILL INTO PRECAST BASE AND SET ANCHORS USING EPDXY GROUT CONCRETE ANTI -FLOTATION BLOCK FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION l€GADAN�� The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER (V // V Z 00 SS '� SEAL ��•� 33782 14. REVISION N0. DATE PLAN INFORMATION PROJECT NO. RYN-17010 FILENAME RYN17010-SWC W�wN JAA W Q SCALE Q � z SHEET V J (� LU Q Z o�F_ O �0° DG � LU 7 m U_ a ��D Z o o U SS '� SEAL ��•� 33782 14. REVISION N0. DATE PLAN INFORMATION PROJECT NO. RYN-17010 FILENAME RYN17010-SWC CHECKED BY JAA DRAWN BY JSM SCALE N.T.S. DATE 11. 26. 2018 SHEET STORMWATER CONTROL MEASURE 'C' DETAILS #6 REBAR PERIMETER FRAME 4" x 4" 6/6 WELDED WIRE FABRIC (EACH SIDE & TOP OF CAGE) 18" (TYP.) 2.03' 4" ANCHOR DEPTH CONTRACTOR SHALL DRILL INTO PRECAST EXTENDED BASE AND SET ANCHORS USING EPDXY GROUT 4"0 GRADE 8 STAINLESS STEEL 4 CONCRETE LAG SCREW 12" X 4" X" GALVANIZED STEEL ° STRAP (4 PER RISER JOINT) 3.0" v 2 LF 8"0 DIP ' 4 ° 4 d 4 4 d da d 0.86' (CENTER TO CENTER) RISER JOINT CONNECTION DETAIL N.T.S. 4" x 4" 6/6 WELDED WIRE FABRIC (EACH SIDE & TOP OF CAGE) CONTRACTOR SHALL SEAL THE PIPE PENETRATION USING A RUBBER BOOT AND STAINLESS STEEL HARDWARE �"--8" PLUG VALVE. THE VALVE a. SHALL BE A M&H STYLE 1820 X -CENTRIC VALVE OR d ENGINEER APPROVED EQUAL. 4 THIS VALVE SHALL BE IN ACCORDANCE WITH AWWA C-517, AND SHALL BE d4' 4 OPERABLE FROM TOP OF OUTLET STRUCTURE VIA A HANDWHEEL. #6 REBAR PERIMETER FRAME 8"0 DIP DRAIN PIPE CONTRACTOR SHALL CORE -DRILL THE HOLE FOR THE 8"0 DIP IN THE FIELD. PRECASTER SHALL OMIT REINFORCEMENT IN THIS AREA. 2.00' NOTES: 1. CONCRETE ANTI -FLOTATION BLOCK TO BE PROVIDED WITH MINIMUM TEMPERATURE AND SHRINKAGE STEEL REINFORCEMENT. 2. TRASH RACKS NOT SHOWN FOR CLARITY. 3. THE NUMBER OF GUIDES FOR THE VALVE STEM SHALL BE DETERMINED IN THE FIELD BY THE CONTRACTOR. THE VALVE STEM MUST BE OPERABLE FROM THE TOP OF THE RISER VIA THE HANDWHEEL WITH AN INSIGNIFICANT AMOUNT OF PLAY IN THE VALVE STEM. 4. CONTRACTOR SHALL PROVIDE A JOINT IN THE OUTLET BARREL NO MORE THAN 5 -FT FROM THE RISER. CONTRACTOR SHALL PRC -- STEPS IN ACCORDANCE NCDOT STD. 840.66. S SHALL BE PLACED AT 16" (SEE DE 1.0"0 OR INV. = 8t L Y a SIPHON W/ 1.5"0 DRILLED OR LO INV. = 8`. 5; (SEE DETAIL SHEET SW 0 ti 0 M N c\i 8" DIP DRAIN W/ TRASH RACK (SEE DETAIL 21" CONCRETE ANTI -FLOTATION I CONTRACTOR SHALL FORM RISER STRUCTURE TO DRAIN POSITIVELY TO INVERT OF OUTLET BARREL USING NON -SHRINK GROUT 8"0 EMERGENCY DIP DRAIN TRASHRACK DETAILS 80 DIP DRAIN PIPE CONTRACTOR SHALL CORE -DRILL THE HOLE FOR THE 8"0 DIP IN THE FIELD. PRECASTER SHALL OMIT REINFORCEMENT IN THIS 4 AREA 4 6" MIN. WALL 8" PLUG VALVE. THE VALVE THICKNESS SHALL BE A M&H STYLE 1820 X -CENTRIC VALVE OR 4. APPROVED EQUAL. THIS VALVE SHALL BE IN ACCORDANCE WITH AWWA C-517, AND SHALL BE OPERABLE FROM TOP OF OUTLET STRUCTURE M n VIA A HANDWHEEL. d ° v v a. . ° 4 d 2 LF 8"0 DIP ° CONTRACTOR SHALL SEAL THE PIPE 4 ° PENETRATION USING A RUBBER BOOT AND STAINLESS STEEL HARDWARE v OM v NOTES: INSTALL ALL STEPS PROTRUDING 4" FROM INSIDE FACE OF STRUCTURE WALL. �HE 0 O G ;I STEPS DIFFERING IN DIMENSIONS, CONFIGURATION, OR MATERIALS FROM THOSE SHOWN MAY ALSO BE USED PROVIDED CONTRACTOR HAS FURNISHED Q QCn z0 THE ENGINEER WITH DETAILS OF THE PROPOSED STEPS AND HAS RECEIVED WRITTEN APPROVAL FROM THE ENGINEER FOR THE USE OF SUCH STEPS. Z F = DH070 MIN./MAX. HIm a PIPE DIA. BAR SIZE �- Hz�=D _ W1 W2 000=Z DC =OC>DZ/9>m @ 8" 1..m 2.00/3.75 LU z1=4 OF= 1 4 #5 ¢0�0r�I,i �H Ow 00MZ 3.00/3.75 1.25/2.00 - \ LL �A�'' > \ @ 8" °1 Z HOC .� Cn 1-40- cri_ 6.50/6.75 2.0 N 0- O w O z I 4.00/4.75 .� a 7.50/8.25 2.5 #5 1 I �-- ►I PLAN SIDE 2.00/3.00 4.50/5.50 10.00/11.50 3.0 ELEVATION @ B" 3.00/3.50 PLAN SIDE 2.75/3.50 5.25/5.75 11.50/11.75 3.5 ELEVATION - 3.25/4.50 6.00/6.75 3.25/3.50 6.00/6.75 �d• cR N #5 M rn -., 6.50/7.00 3.25/3.50 N Cc CL Z G7 4.5 #5 @ 8" 0 LV W F.. r 1 D 141^2 13.50/15.75 z N #5 CAST IRON 4.50/5.00 CAST IRON 3.25/4.00 � ELEVATION ELEVATION #5 @ B" m 7.50/8.50 3.25/4.00 7.25/9.25 OWC 6.0 #5 @ 8" 4.50/5.00 o� Z 7.75/9.25 14.75/16.75 D 8 #6 BAR OR BARv GALV'D. Q#8 N 11/4 1/4 CA r ` � U) LU rn a G7 POLYPROPYLENE PLAN = H z m 1� SIDE PLASTIC SIDE z Q ELEVATION PLAN ELEVATION w DC CA COMPOSITE REINFORCING STEEL ELEVATION #3 DEFORMED 12 I DO NOT USE IN STEEL ROD SECTION A -A _jNOTE: ELEVATION SANITARY SEWER MANHOLES. SHEET 1 OF 1 SHEET 1 OF 1 840.66 840.66 N.T.S. 8.00' PRECASTER SHALL PROVIDE A BLOCK OUT FOR THE 0M 24"0 0 -RING RCP r-1 d v CONCRETE COLLAR aoCn' 0 °Q d e (TO BE CONSTRUCTED IN THE >"-m _n � Cn 1.50' 1.50' ° 5.00' 1.50 FIELD BY THE CONTRACTOR - H z = y 4 SEE DETAIL SHEET SW -C2) = O y n m =(np0 44 `� v z,_,_v -n ej d �) 0 8" DIP DRAIN W/ TRASH RACK �' 4 Qom---- CONCRETE CRADLE >> (SEE DETAIL) d d ° 4 ° (SEE DETAIL ON H Id. ° SHEET SW -C4) CD z 0 d - - - - - - - - - a 4 v 8.00' 5.00' d d 24"0 0 -RING RCP A* FLOW -► v SIPHON W/ 1.5"0 DRILLED ORIFICE d m INV. = 854.00 (SEE DETAIL SHEET SW -C2) d d z M 0 Z0H 1.0"0 ORIFICE v ° a a m� Z 855.30 d i -4 Cn 4 4 N 4 4 d 0 z 0 a• C Z > 1.50' d 4'a a �=0 d 1" THICK JOINT FILLER MATERIAL Nm 4. d (TYP.) N M D v � STI m H 8"0 PLUG VALVE. THE VALVE SHALL BE A M&H 0 STYLE 820 X -CENTRIC VALVE OR APPROVED EQUAL.10 THIS VALVE SHALL BE IN ACCORDANCE WITH AWWA �► 0 C-504 SEC. 5.5, AND SHALL BE OPERABLE FROM � TOP OF OUTLET STRUCTURE VIA A HANDWHEEL. M CONTRACTOR SHALL PROVIDE STEPS IN ACCORDANCE WITH NCDOT STD. 840.66. STEPS SHALL BE PLACED AT 16" O.C. TOP OF HANDWHEEL TO EXTEND 1 -FOOT ABOVE TRASH RACK SHEET 1 OF 1 838.80 7.50' 9.75' 0.50' 1.75' TOP OF RISER EL. = 858.50 VALVE STEM GUIDE (SEE NOTE #3) 1.0"0 ORIFICE = 855.30 SIPHON W/ 1.5"0 DRILLED ORIFICE INV. = 854.00 (SEE DETAIL SHEET SW -C2) 8" DIP DRAIN W/ TRASH RACK -� (SEE DETAIL) INVERT OUT EL. = 851.00 CONTRACTOR SHALL PROVIDE STEPS IN ACCORDANCE WITH NCDOT STD. 840.66. STEPS SHALL BE PLACED AT 16" O.C. (SEE DETAIL) 4 PRECASTER SHALL PROVIDE A BLOCK OUT FOR THE 24"0 0 -RING RCP CONCRETE COLLAR o (TO BE CONSTRUCTED IN THE FIELD BY 4 THE CONTRACTOR - SEE DETAIL SW -C2) 4 0 4 d d' d 24"0 0 -RING RCP d FLOW -�- ° 4 4 O - u d u G ° d . 4 4 4 4 CONCRETE ANTI -FLOTATION BLOCK 4 ° d CONTRACTOR SHALL FORM INVERT OF RISER STRUCTURE TO DRAIN POSITIVELY TO INVERT OF OUTLET BARREL USING NON -SHRINK GROUT PERMANENT OUTLET STRUCTURE DETAILS N.T.S. 4CONCRETE CRADLE d 4 4 (SEE DETAIL ON SHEET SW -C4) 1" THICK JOINT FILLER MATERIAL W1 FT. �8" D.C.(TYP.) REFER TO CHART FOR BAR SIZE ELEVATION PLAN MAINTENANCE ACCESS STEPS N.T.S. z 000 1-4 NOTES: H Q D 6" * THIS PRECAST ENDWALL MAY BE USED FOR THE FOLLOWING F2n= = 0 STANDARDS: 838.01, 838.11, 838.21, 838.27, 838.33, LL J a H Z 838.39, 838.51, 838.57, 838.63 AND 838.69. 0 a z _ INSTALL PRECAST ENDWALLS WITH WINGS AND PAY w Q dU_ = * FOR IN ACCORDANCE WITH SPECIFICATION SECTION 838. ~Q 0 O H USE 4000 PSI CONCRETE. H = Z w * PROVIDE ALL REINFORCING STEEL WHICH MEETS ASTM A615 0 ALL OJ FOR GRADE 60 AND WELDED WIRE FABRIC CONFORMING p O F -4 Q p I TO ASTM A185 WITH 2" MIN. CLEARANCE. Z 1-i H2F- H * PLACE LIFT HOLES OR PINS IN ACCORDANCE WITH OSHA STANDARD 1926.704. �- G7 LLJ H1 I PIPE TO BE GROUTED INTO HEADWALL AT JOB SITE BY r a CONTRACTOR ALL ELEMENTS PRECAST TO MEET ASTM C913. V-01 --��- * WELDED WIRE ABRIC MAY BE SUBSTITUTED FOR REBAR AS LONG AS THE SAME AREA OF STEEL IS PROVIDED. * CHAMFER ALL CORNERS 1" OR HAVE A RADIUS OF 1". e" 0.C.(TYP.) REFER TO CHART FOR BAR SIZE w NOTE: THE MINIMUM BAR SIZE SHALL BE #5 BARS J Y SIDE 8' CTS.THE CONTRACTOR WILL HAVE THE OPTION O Zi SIDE TO INCREASE THIS BAR SIZE AS NEEDED. LL a0 Im H z ' Q W a ENDWALL DIMENSIONS 4. LN °- FT. 4 MIN./MAX. MIN./MAX. MIN./MAX. MIN./MAX. a PIPE DIA. BAR SIZE �- 4 d --- W1 W2 1.0 #5 @ 8" v 2.00/3.75 1.25/1.75 3.00/3.75 a 4 #5 @ 8" 1.25/2.00 3.00/3.75 1.25/2.00 d 4 1.50 d. @ 8" 4 d 3.00/4.25 1.50/2.50 3.50/3.75 6.50/6.75 2.0 #5 4CONCRETE CRADLE d 4 4 (SEE DETAIL ON SHEET SW -C4) 1" THICK JOINT FILLER MATERIAL W1 FT. �8" D.C.(TYP.) REFER TO CHART FOR BAR SIZE ELEVATION PLAN MAINTENANCE ACCESS STEPS N.T.S. z 000 1-4 NOTES: H Q D 6" * THIS PRECAST ENDWALL MAY BE USED FOR THE FOLLOWING F2n= = 0 STANDARDS: 838.01, 838.11, 838.21, 838.27, 838.33, LL J a H Z 838.39, 838.51, 838.57, 838.63 AND 838.69. 0 a z _ INSTALL PRECAST ENDWALLS WITH WINGS AND PAY w Q dU_ = * FOR IN ACCORDANCE WITH SPECIFICATION SECTION 838. ~Q 0 O H USE 4000 PSI CONCRETE. H = Z w * PROVIDE ALL REINFORCING STEEL WHICH MEETS ASTM A615 0 ALL OJ FOR GRADE 60 AND WELDED WIRE FABRIC CONFORMING p O F -4 Q p I TO ASTM A185 WITH 2" MIN. CLEARANCE. Z 1-i H2F- H * PLACE LIFT HOLES OR PINS IN ACCORDANCE WITH OSHA STANDARD 1926.704. �- G7 LLJ H1 I PIPE TO BE GROUTED INTO HEADWALL AT JOB SITE BY r a CONTRACTOR ALL ELEMENTS PRECAST TO MEET ASTM C913. V-01 --��- * WELDED WIRE ABRIC MAY BE SUBSTITUTED FOR REBAR AS LONG AS THE SAME AREA OF STEEL IS PROVIDED. * CHAMFER ALL CORNERS 1" OR HAVE A RADIUS OF 1". e" 0.C.(TYP.) REFER TO CHART FOR BAR SIZE w NOTE: THE MINIMUM BAR SIZE SHALL BE #5 BARS J Y SIDE 8' CTS.THE CONTRACTOR WILL HAVE THE OPTION O Zi SIDE TO INCREASE THIS BAR SIZE AS NEEDED. LL a0 Im H z ' OUTLET ENDWALL DETAILS N.T.S. NOTES: 1. CONTRACTOR SHALL PROVIDE A JOINT IN THE OUTLET BARREL NO MORE THAN 5 -FT FROM THE RISER. 1" THICK JOINT FILLER MATERIAL 4 v d d 4 v 4 4 d 4 - - - - - - - 4 v a 4- d 4 Q a .4 24"0 0 -RING RCP FLOW �. 4 4 d d d va 4 d. d 4 v 4 d 4 d. 4 d 4 d d v a Q W a ENDWALL DIMENSIONS d LN °- FT. MINIMUM MIN./MAX. MIN./MAX. MIN./MAX. MIN./MAX. MIN. IMAX. PIPE DIA. BAR SIZE H1 (FT.) H2(FT.) D (FT.) W1 W2 1.0 #5 @ 8" 1.25/2.00 2.00/3.75 1.25/1.75 3.00/3.75 5.50/6.00 1.25 #5 @ 8" 1.25/2.00 3.00/3.75 1.25/2.00 3.50/3.75 6.50/6.75 1.50 #5 @ 8" 1.25/2.00 3.00/4.25 1.50/2.50 3.50/3.75 6.50/6.75 2.0 #5 @ 8" 1.50/2.50 4.00/4.75 1.75/2.50 4.00/4.25 7.50/8.25 2.5 #5 @ B" 2.50/3.50 4.00/6.00 2.00/3.00 4.50/5.50 10.00/11.50 3.0 #5 @ B" 3.00/3.50 5.0016.00 2.75/3.50 5.25/5.75 11.50/11.75 3.5 #5 @ 8" 3.25/4.50 6.00/6.75 3.25/3.50 6.00/6.75 12.00/13.25 4.0 #5 @ B" 3.50/4.50 6.50/7.00 3.25/3.50 6.50/6.75 13.00/13.25 4.5 #5 @ 8" 4.00/5.00 6.50/8.50 3.25/4.00 7.00/9.25 13.50/15.75 5.0 #5 @ B" 4.50/5.00 7.00/8.50 3.25/4.00 7.25/9.25 13.75/15.75 5.5 #5 @ B" 4.50/5.00 7.50/8.50 3.25/4.00 7.25/9.25 14.00/15.75 6.0 #5 @ 8" 4.50/5.00 7.50/8.50 3.25/4.00 7.75/9.25 14.75/16.75 OUTLET ENDWALL DETAILS N.T.S. NOTES: 1. CONTRACTOR SHALL PROVIDE A JOINT IN THE OUTLET BARREL NO MORE THAN 5 -FT FROM THE RISER. 1" THICK JOINT FILLER MATERIAL 4 v d d 4 v 4 4 d 4 - - - - - - - 4 v a 4- d 4 Q a .4 24"0 0 -RING RCP FLOW �. 4 4 d d d va 4 d. d 4 v 4 d 4 d. 4 d 4 d d v a CONCRETE COLLAR (SEE DETAIL SHEET SW -C2) 24"0 0 -RING RCP FLOW -+- a 4'. d d 4 4 4 --4-.- - a d v a a The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER Q W a RYN17010-SWC d LN °- DRAWN BY JSM ~ z�00 C] LU N SHEET o U W Q <z� 0 Cl) V) Q N _ 1�_ .- �G c/� CO) w �a_j O C X00 z H LU w w W z cc D. o z LL CONCRETE COLLAR (SEE DETAIL SHEET SW -C2) 24"0 0 -RING RCP FLOW -+- a 4'. d d 4 4 4 --4-.- - a d v a a The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER -9. t SEAL r _ 33782 ••N •• ... PCO,,,` REVISIONS NO. DATE PLAN INFORMATION PROJECT NO. RYN-17010 FILENAME RYN17010-SWC CHECKED BY (L) V DRAWN BY JSM SCALE z�00 DATE Q0 SHEET Liu W Q oC z Cr 0 V) Q U �G z -1v O O C X00 1� W z cc z coO U -9. t SEAL r _ 33782 ••N •• ... PCO,,,` REVISIONS NO. DATE PLAN INFORMATION PROJECT NO. RYN-17010 FILENAME RYN17010-SWC CHECKED BY IAA DRAWN BY JSM SCALE N.T.S. DATE 11. 26. 2018 SHEET 1" THICK JOINT �- 1" THICK JOINT FILLER MATERIAL FILLER MATERIAL STORMWATER CONTROL BLOCK CONCRETE ANTI -FLOTATION MEASURE ' C' DETAILS CONCRETE TOP VIEW SIDE VIEW ANTI -FLOTATION BLOCK RISER BARREL/CRADLE CONNECTION DETAIL sw�c N.T.S. FINAL DRAWING -NOT RELEASED FOR CONSTRUCTION NOTE: NOTES: 1. AS AN ALTERNATE TO A CONCRETE CRADLE UNDER THE BARREL PIPE (THIS DETAIL), THE CONTRACTOR 1. A FILTER BLANKET IS TO BE INSTALLED BETWEEN THE RIPRAP AND SOIL FOUNDATION. THE FILTER BLANKET MAY CHOOSE TO ELIMINATE THE CONCRETE CRADLE AND USE COMPACTED BACKFILL IF THE ON-SITE WILL CONSIST OF A MINIMUM 4" THICK LAYER OF STONE (NCDOT #57) UNDERLAIN WITH MIRAFI FILTER GEOTECHNICAL ENGINEER WILL PROVIDE A NC PE SEALED LETTER CERTIFYING THAT THE COMPACTION WEAVE 700 OR APPROVED EQUIVALENT UNDER, AROUND, AND ABOVE THE BARREL MEETS THE SPECIFICATIONS OF THE EMBANKMENT COMPACTION REQUIREMENTS AND MOISTURE CONTENT. THIS CERTIFICATION LETTER MUST BE 66" MIN. SUBMITTED TO THE DESIGN ENGINEER BEFORE AS -BUILT CERTIFICATION OF THE FACILITY. THIS SEPARATE CERTIFICATION MUST BE SPECIFIC TO THE BARREL PIPE FOR THE FACILITY, AND MUST CLEARLY STATE THAT ALL SOIL MATERIAL UNDER, AROUND, AND ABOVE THE BARREL PIPE MEETS THE BERM AND SOIL NCDOT CLASS "B" RIPRAP COMPACTION SPECIFICATIONS STATED ON SHEET SW -C1. THIS CERTIFICATION IS TO INCLUDE REFERENCE 121 x 6'W x 22" THICK 240 O-RING RCP TO BOTH MATERIAL AND COMPACTION, AND MUST STATE THAT ALL MATERIALS UNDER, AROUND, AND ABOVE THE BARREL HAVE BEEN COMPACTED PER THE BERM MATERIAL SPECIFICATIONS (AT LEAST 95% OF - MAXIMUM DRY DENSITY USING ASTM D698 STANDARD PROCTOR) WITH NO VOID SPACES PRESENT. THE ENDWALL PER CONTRACTORS INTENT TO UTILIZE THIS ALTERNATIVE MUST BE STATED PRIOR TO CONSTRUCTION TAKING 1 NCDOT STD. 838.80 PLACE. THIS CONTRACTORS CERTIFICATION MUST BE PRESENTED TO THE DESIGN ENGINEER BEFORE AN / 1 AS -BUILT CERTIFICATION CAN BE ISSUED FOR THIS FACILITY. (MIN.) ENDWALL PER 18- NCDOT 8 NCDOT STD. 838.80 o O 1 BARREL PIPE FLOWABLE FILL CRADLE 24"0 0 -RING RCP _ 24"0 0 -RING RCP o CONSTRUCTION SEQUENCE A ------------- Oa O A 1. CONSTRUCT FORMWORK FOR FLOWABLE FILL CRADLE ON EXISTING GRADE. .�• • ^ :. `:• 62. EXCAVATE TRENCH FOR CRADLE AND BARREL PER DIMENSIONS ON DRAWINGS. 15 ° --------------- 3. PLACE BARREL PIPE ON CONCRETE BLOCKS TO GRADE. CONTRACTOR SHALL WRAP JOINTS WITH 2 -FT WIDE •" °' . ' STRIPS OF FABRIC AT THIS STEP. --------------- 22" LAYER OF •e ' :. , • 750 PSI PLOWABLE FILL 0 0 o 0 0 0 4. PLACE FLOWABLE FILL FOR CRADLE FOR EACH SECTION FROM ONE SIDE OF THE TRENCH. ALLOW FLOWABLE : • a ; .+ . •. "• ° : .. .,; ' : • ` —1- CLASS B RIPRAP ; . "d .: FILL TO FILL ENTIRE AREA UNDER PIPE AND PIPE HAUNCHES AS TO LEAVE NO VOIDS UNDER THE PIPE BEFORE ° ! •' :' ••q < III—III— I I- I w1i FILTER BLANKET PLACING PLOWABLE FILL ON THE OPPOSITE SIDE OF THE TRENCH. PLACE ENTIRE CRADLE AS ONE LIFT %• ''•O12" MIN...°. :.•°I (VERTICALLY) PER DRAWINGS. a•..4 ° :• ",• ' •. f. a d� - 5. FLOWABLE FILL CRADLE MAY BE ELIMINATED PER RECOMMENDATION FROM THE ON-SITE GEOTECHNICAL FILTER BLANKET ENGINEER. ANY DEVIATION FROM THIS DETAIL SHALL BE SUBMITTED TO AND REVIEWED BY THE DESIGN (SEE NOTE) ENGINEER PRIOR TO IMPLEMENTATION. IF THE CRADLE IS ELIMINATED, THEN A LETTER FROM AN NC PE - - CERTIFYING THAT ALL SOIL MATERIAL UNDER, AROUND, AND ABOVE THE BARREL PIPE MEETS THE BERM - 12' MATERIAL SPECIFICATIONS STATED ON SHEET SW -C1 IS REQUIRED. 6. ALLOW CRADLE TO CURE FOR A MINIMUM OF 7 DAYS BEFORE ANY VIBRATING COMPACTION EQUIPMENT IS PLAN SECTION A -A USED IN THE VICINITY OF THE BARREL PIPE. 7. TRENCH TO BE BACKFILLED IN 5" LIFTS WHEN COMPACTION IS BY HAND. BACKFILL IS IN 8" LIFTS WHEN CONDUCTED BY MACHINE. MINIMUM OF 2 FEET COVER MUST BE PRESENT ON 24,10 RCP BEFORE DRIVING OVER WITH HEAVY EQUIPMENT. OUTLET (BARREL VELOCITY DISSIPATOR 24" CONCRETE CRADLE DETAIL N.T.S. N.T.S. 8'-6- 2'- 6" '-6"2'-6" 0. D. (2) 4" PERFORATED, CORRUGATED HDPE PIPE (ADS N-12 OR i I APPROVED EQUIVALENT) i 24"0 0 -RING RCP co, C to O OO� o o Oo 0 o OaOo Oa Oa aaaaa aaa aaaaa OaoaCD CaoD Deese 4'-0" O Co CJO o Co Q �JO�O aaaacz aeases o aaaa� asao 0 0 �aaa�aa sasses ease ease o�oajo�0a �ca0 ooao�o�ca� aaao aao ENDWALL PER NCDOT STD. 838.80 NOTE: 4" WEEPHOLES TO BE PROVIDED WITH VARMIT GUARD ON DOWNSTREAM SIDE N0. 67 WASHED STONE ENCASED IN NON -WOVEN AND GALVANIZED HARDWARE CLOTH ON GEOTEXTILE FABRIC (MIRAFI UPSTREAM SIDE (Ya" MAXIMUM OPENINGS) 180N OR EQUIVALENT) PROPOSED GRADE 3' MIN. 3' MIN. 6" MIN. F_ III=III=1 I III=III=III=III=III-I I Ia ENDWALL PER III—III- NCDOT STD. 838.80 as (a, 0 0 O 0 0 i I -III -1' MIN. � �o�o 0 o a�aaa� o aa� ENDWALL PER --------- - - - - NCDOT STD. 838.80 0 0':_5�co 0C:524"0 0 -RING RCP C�'"I4.5' MIN. FLOW ooa oa oa O o Oa o 124 0 0 -RING RCP Oa�O O� oa oa oa oO a? Co g--------- a 0 1' MIN. a a a a a _ CIN 0 0 0 0 0 N Ol N (2) 4" PERFORATED, 3 CORRUGATED HDPE PIPE NO. 67 WASHED STONE (ADS N-12 OR NO. 67 WASHED STONE ENCASED IN NON -WOVEN APPROVED EQUIVALENT) ENCASED IN NON -WOVEN FILTER FABRIC (MIRAFI 180N GEOTEXTILE FABRIC (MIRAFI (2) 4" PERFORATED, OR EQUIVALENT) 180N OR EQUIVALENT) CORRUGATED HDPE PIPE (ADS N-12 OR N APPROVED EQUIVALENT) bo .3 m 0 v U to .3 o 0 0 C SPILLWAY FILTER DETAIL U N.T.S. E `2 0 0 z z r FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION JU i'e/jCADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER ry 11 V z�or-01 CARp��''%. 44 ti . SEAL �� I _ " 3378 N A. PL�.• REVISIONS N0. DATE PLAN INFORMATION PROJECT NO. RYN-17010 FILENAME RYN17010-SWC CHECKED BY IAA DRAWN BY JSM SCALE N.T.S. DATE 11. 26. 2018 SHEET STORMWATER CONTROL MEASURE 'C' DETAILS SW -C4 W�SwN W Q rvol z_ 1..1cyo � v J LU U �Cz O O 2 ou ® z z co re Q z O o0c U CARp��''%. 44 ti . SEAL �� I _ " 3378 N A. PL�.• REVISIONS N0. DATE PLAN INFORMATION PROJECT NO. RYN-17010 FILENAME RYN17010-SWC CHECKED BY IAA DRAWN BY JSM SCALE N.T.S. DATE 11. 26. 2018 SHEET STORMWATER CONTROL MEASURE 'C' DETAILS SW -C4 STORMWATER CONTROL MEASURE 'C' LANDSCAPE SPECIFICATIONS LEGEND QTY. SYM. SCIENTIFIC NAME COMMON NAME HATCH TYPE SPACING TEMPORARY INUNDATION SEEDBED PREPARATION 1. CHISEL COMPACTED AREAS AND SPREAD TOPSOIL 3 INCHES DEEP OVER ADVERSE SOIL CONDITIONS, IF AVAILABLE. 2. RIP THE ENTIRE AREA TO 6 INCHES DEPTH. 3. REMOVE ALL LOOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING SURFACE REASONABLY SMOOTH AND UNIFORM. 4. PER ONE TIME ONLY, APPLY AGRICULTURAL LIME, FERTILIZER, AND SUPERPHOSPHATE UNIFORMLY AND MIX WITH SOIL. 5. CONTINUE TILLAGE UNTIL WELL -PULVERIZED, FIRM REASONABLY UNIFORM SEEDBED IS PREPARED 4TO 6 INCHES DEEP. 6. SEED ON A FRESHLY PREPARED SEEDBED AND COVER. 7. MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH. 8. INSPECT ALL SEEDED AREAS AND MAKE NECESSARY REPAIRS OR RESEEDINGS WITHIN THE PLANTING SEASON, IF POSSIBLE. AFTER PERMANENT COVER IS ESTABLISHED. 9. CONSULT CONSERVATION INSPECTOR ON MAINTENANCE TREATMENT PERMANENT SEEDING SCHEDULE (DAM EMBANKMENTS) SEEDING DATE SEEDING MIXTURE APPLICATION RATE APRIL 15 -JUNE 30 BERMUDAGRASS 25 LBS/AC SOIL AMENDMENTS APPLY LIME AND FERTILIZER FOLLOWING RECOMMENDATIONS OF SOIL TESTS OR APPLY 3,000 LB/AC GROUND AGRICULTURE LIMESTONE AND 500 LB/AC 10-10-10 FERTILIZER. MULCH APPLY 4000 LB/AC STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE REFERTILIZE THE FOLLOWING APRIL WITH 50 LB/AC NITROGEN. REPEAT AS GROWTH CONTINUES. MAY BE MOWED ONLY ONCE PER YEAR. SEEDING NOTES USE BERMUDAGRASS ONLY ON ISOLATED SITES WHERE IT CANNOT BECOME A PEST. NOTE: PERMANENT SEEDING SCHEDULE IS FOR SLOPES OF THE BASIN, TOP OF BERM, AND BASIN FLOOR. PLANTING INSTRUCTIONS PLANTING TECHNIQUES A. INSURE THAT ROOTS, ONCE REMOVED FROM POT, ARE STRAIGHTENED AND FACE DOWNWARD. B. CREATE PLANTING AREA FOR EACH PLANT AND EXCAVATE PIT. C. PLACE PLANTS IN PIT INSURING ROOTS ARE FACING COMPLETELY DOWNWARD. D. HEEL IN SOIL AROUOND PLANT AND PROCEED TO NEXT PLANTING LOCATION. E. NEWLY PLANTED PLANTS NEED TO BE FASTENED TO THE SUBSTRATE FOR THE ESTABLISHMENT OF NEW ROOTS. F. ROOTS SHALL BE SPREAD IN THEIR NORMAL POSITION. ALL BROKEN OR FRAYED ROOTS HALL BE CUT OFF CLEANLY. G. THE DIAMETER OF THE PITS FOR ALL VEGETATIVE STOCK SHALL BE AT LEAST THREE TIMES THE DIAMETER OF THE ROOT MASS. PLANT PIT WALL SHALL BE SCARIFIED PRIOR TO PLANT INSTALLATION. H. SET THE PLANTS UPRIGHT, IN THE CENTER OF THE PIT. THE BOTTOM OF THE ROOT MASS SHOULD BE RESTING ON UNDISTURBED SOIL. I. PLACE THE BACKFILL AROUND THE BASE AND SIDES OF THE ROOT MASS, AND WORK EACH LAYER TO SETTLE BACKFILL AND TO ELIMINATE VOIDS AND AIR POCKETS. WHEN PIT IS APPROXIMATELY 2/3 FULL, WATER THOROUGHLY BEFORE PLACING REMAINDER OF THE BACKFILL. WATER AGAIN AFTER PLACING FINAL LAYER OF BACKFILL. J. BROKEN OR DAMAGED PARTS WILL BE CUT BACK TO UNDAMAGED TISSUE, LEAVING AS MUCH GREEN BASAL TISSUE AS POSSIBLE ABOVE THE ROOTS. IF MORE THAN FIFTY PERCENT (50%) OF THE PLANT IS DAMAGED THEN CONTRACTOR SHALL REPLACE THE PLANT. CONTAINER STOCK / BARE ROOT A. STOCK SHALL HAVE BEEN GROWN IN A CONTAINER LONG ENOUGH FOR THE ROOT SYSTEM TO HAVE DEVELOPED SUFFICIENTLY TO HOLD ITS SOIL TOGETHER ONCE REMOVED FROM THE CONTAINER. B. CONTAINER PLANTS WILL NEED TO BE WATERED REGULARLY AND PLACED IN SHADY CONDITIONS UNTIL PLANTING OCCURS. C. BARE ROOT PLANTS ARE FOR IMMEDIATE PLANTING, OTHERWISE SEE D) BELOW. D. IF BARE ROOTS SPECIMENS ARE NOT TO BE PLANTED WITHIN FOUR (4) DAYS, TEMPORARY HOLDING OF BARE ROOT SPECIMENS ARE TO BE COVERED ENTIRELY BY A SUITABLE MEDIUM (ETC. SOIL, SAWDUST, MULCH OR THE LIKE) AND WATERED REGULARLY SO AS TO NOT DRY OUT. PLANT LOCATIONS A. NEW PLANTINGS SHALL BE LOCATED WHERE SHOWN ON PLAN EXCEPT WHERE CHANGES HAVE BEEN MADE IN PROPOSED CONSTRUCTION. B. NECESSARY ADJUSTMENTS SHALL BE MADE ONLY AFTER APPROVAL BY THE OWNER OR THE OWNER'S REPRESENTATIVE. WATER WATER SHALL BE POTABLE AND SHALL NOT CONTAIN ELEMENTS TOXIC TO PLANT LIFE. TEMPORARY SEEDING SCHEDULE SEEDING DATE SEEDING MIXTURE APPLICATION RATE JAN 1 - MAY 1 RYE (GRAIN) 120 LBS/AC KOBE LESPEDEZA 50 LBS/AC MAY 1- AUG 15 GERMAN MILLET 40 LBS/AC AUG 15 - DEC 31 RYE (GRAIN) 120 LBS/AC SOIL AMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/AC GROUND AGRICULTURE LIMESTONE AND 750 LB/AC 10-10-10 FERTILIZER (FROM AUG 15 - DEC 31, INCREASE 10-10-10 FERTILIZER TO 1000 LB/AC). MULCH APPLY 4000 LB/AC STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED ASA MULCH ANCHORING TOOL. MAINTENANCE JAN 1 - AUG 15: REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE, AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. AUG 15 - DEC 31: REPAIR AND REFERTILIZE DAMAGED AREAS IMMEDIATELY. TOP DRESS WITH 50 LB/AC OF NITROGEN IN MARCH. IF IT IS NECESSARY TO EXTEND TEMPORARY COVER BEYOND JUNE 15, OVERSEED WITH 50 LB/AC KOBE LESPEDEZA IN LATE FEBRUARY OR EARLY MARCH. NOTE: USE THE TEMPORARY SEEDING SCHEDULE ONLY WHEN DATE IS NOT CORRECTTO USE THE PERMANENT SEEDING SCHEDULE. 132, I � Co EX. WETLAND , I / I / / / l l f I mO Illi, SEWER EASEMENT IIII I IIIIII I / III 11 1 /lll 1 1 lI I I I I l I I 1 1 l l l / I II II III I l I ISI 11 11�1II III I I I I I I I I I I I l \ l I l / Io j FOREE AY x\���A 98 PC 73 ST 1 1 \ 65AI t 1 II / / // v 75 EF 118 N TEMPORARY,- - 111 INUNDATION ZONE 66 LC ��� 109 I 00O / / i O /X0000 00 000 /opo 60 / / �� 00 03 00 00 /00 61 PC 00 00 00 /CD 00 / X / / /�/ 00 o0 123 Al // /00 /� �� I Q 106 EF MICR 9 POOLi 11 J,/ o� a STORMWATER CONTROL MEASURE/ MAINTENANCE/ACCESS EASEMENT / / // / / / / / I / I I I 1I / / / CO o l I 1 / / /�// _ PROPERTY LINE � �, l // / ' I // 25' PERIMETER BUFFER /l 11 I' l �' � // Il \ �� v / �� I x� 1 GRAPHICSCALE /l 0 10 O0 40 1 inch = 20 ft. STORMWATER CONTROL MEASURE 'C' LANDSCAPE PLAN 1" = 20' FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER (v�I V z�� UDo FILENAME RYN17010-SWC W ?:wN LU 188 Al ASCLEPIAS INCARNATE SWCMP MILKWEED z 4 -INCH CONTAINER 24" O.C. J (� Z �C 181 EF EUPATORIADELPHUS JOE PYE WEED O 4 -INCH CONTAINER 24" O.C. F_ FISTULOSUS � 0 0 175 LCLOBELIA CARDINALIS CARDINAL FLOWER 4 -INCH CONTAINER 24" O.C. SHALLOW WATER 248 IV IRIS VIRGINIANA BLUE FLAG IRIS 4 -INCH CONTAINER 24" O.C. 176 PC PONTEDERIA CORDATA PICKERELWEED ++++ + + + 4 -INCH CONTAINER 24" O.C. 159 ST SCHOENOPLECTUS SOFT -STEM BULRUSH 4 -INCH CONTAINER 24" O.C. TABERNAEMONTANI SEEDBED PREPARATION 1. CHISEL COMPACTED AREAS AND SPREAD TOPSOIL 3 INCHES DEEP OVER ADVERSE SOIL CONDITIONS, IF AVAILABLE. 2. RIP THE ENTIRE AREA TO 6 INCHES DEPTH. 3. REMOVE ALL LOOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING SURFACE REASONABLY SMOOTH AND UNIFORM. 4. PER ONE TIME ONLY, APPLY AGRICULTURAL LIME, FERTILIZER, AND SUPERPHOSPHATE UNIFORMLY AND MIX WITH SOIL. 5. CONTINUE TILLAGE UNTIL WELL -PULVERIZED, FIRM REASONABLY UNIFORM SEEDBED IS PREPARED 4TO 6 INCHES DEEP. 6. SEED ON A FRESHLY PREPARED SEEDBED AND COVER. 7. MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH. 8. INSPECT ALL SEEDED AREAS AND MAKE NECESSARY REPAIRS OR RESEEDINGS WITHIN THE PLANTING SEASON, IF POSSIBLE. AFTER PERMANENT COVER IS ESTABLISHED. 9. CONSULT CONSERVATION INSPECTOR ON MAINTENANCE TREATMENT PERMANENT SEEDING SCHEDULE (DAM EMBANKMENTS) SEEDING DATE SEEDING MIXTURE APPLICATION RATE APRIL 15 -JUNE 30 BERMUDAGRASS 25 LBS/AC SOIL AMENDMENTS APPLY LIME AND FERTILIZER FOLLOWING RECOMMENDATIONS OF SOIL TESTS OR APPLY 3,000 LB/AC GROUND AGRICULTURE LIMESTONE AND 500 LB/AC 10-10-10 FERTILIZER. MULCH APPLY 4000 LB/AC STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE REFERTILIZE THE FOLLOWING APRIL WITH 50 LB/AC NITROGEN. REPEAT AS GROWTH CONTINUES. MAY BE MOWED ONLY ONCE PER YEAR. SEEDING NOTES USE BERMUDAGRASS ONLY ON ISOLATED SITES WHERE IT CANNOT BECOME A PEST. NOTE: PERMANENT SEEDING SCHEDULE IS FOR SLOPES OF THE BASIN, TOP OF BERM, AND BASIN FLOOR. PLANTING INSTRUCTIONS PLANTING TECHNIQUES A. INSURE THAT ROOTS, ONCE REMOVED FROM POT, ARE STRAIGHTENED AND FACE DOWNWARD. B. CREATE PLANTING AREA FOR EACH PLANT AND EXCAVATE PIT. C. PLACE PLANTS IN PIT INSURING ROOTS ARE FACING COMPLETELY DOWNWARD. D. HEEL IN SOIL AROUOND PLANT AND PROCEED TO NEXT PLANTING LOCATION. E. NEWLY PLANTED PLANTS NEED TO BE FASTENED TO THE SUBSTRATE FOR THE ESTABLISHMENT OF NEW ROOTS. F. ROOTS SHALL BE SPREAD IN THEIR NORMAL POSITION. ALL BROKEN OR FRAYED ROOTS HALL BE CUT OFF CLEANLY. G. THE DIAMETER OF THE PITS FOR ALL VEGETATIVE STOCK SHALL BE AT LEAST THREE TIMES THE DIAMETER OF THE ROOT MASS. PLANT PIT WALL SHALL BE SCARIFIED PRIOR TO PLANT INSTALLATION. H. SET THE PLANTS UPRIGHT, IN THE CENTER OF THE PIT. THE BOTTOM OF THE ROOT MASS SHOULD BE RESTING ON UNDISTURBED SOIL. I. PLACE THE BACKFILL AROUND THE BASE AND SIDES OF THE ROOT MASS, AND WORK EACH LAYER TO SETTLE BACKFILL AND TO ELIMINATE VOIDS AND AIR POCKETS. WHEN PIT IS APPROXIMATELY 2/3 FULL, WATER THOROUGHLY BEFORE PLACING REMAINDER OF THE BACKFILL. WATER AGAIN AFTER PLACING FINAL LAYER OF BACKFILL. J. BROKEN OR DAMAGED PARTS WILL BE CUT BACK TO UNDAMAGED TISSUE, LEAVING AS MUCH GREEN BASAL TISSUE AS POSSIBLE ABOVE THE ROOTS. IF MORE THAN FIFTY PERCENT (50%) OF THE PLANT IS DAMAGED THEN CONTRACTOR SHALL REPLACE THE PLANT. CONTAINER STOCK / BARE ROOT A. STOCK SHALL HAVE BEEN GROWN IN A CONTAINER LONG ENOUGH FOR THE ROOT SYSTEM TO HAVE DEVELOPED SUFFICIENTLY TO HOLD ITS SOIL TOGETHER ONCE REMOVED FROM THE CONTAINER. B. CONTAINER PLANTS WILL NEED TO BE WATERED REGULARLY AND PLACED IN SHADY CONDITIONS UNTIL PLANTING OCCURS. C. BARE ROOT PLANTS ARE FOR IMMEDIATE PLANTING, OTHERWISE SEE D) BELOW. D. IF BARE ROOTS SPECIMENS ARE NOT TO BE PLANTED WITHIN FOUR (4) DAYS, TEMPORARY HOLDING OF BARE ROOT SPECIMENS ARE TO BE COVERED ENTIRELY BY A SUITABLE MEDIUM (ETC. SOIL, SAWDUST, MULCH OR THE LIKE) AND WATERED REGULARLY SO AS TO NOT DRY OUT. PLANT LOCATIONS A. NEW PLANTINGS SHALL BE LOCATED WHERE SHOWN ON PLAN EXCEPT WHERE CHANGES HAVE BEEN MADE IN PROPOSED CONSTRUCTION. B. NECESSARY ADJUSTMENTS SHALL BE MADE ONLY AFTER APPROVAL BY THE OWNER OR THE OWNER'S REPRESENTATIVE. WATER WATER SHALL BE POTABLE AND SHALL NOT CONTAIN ELEMENTS TOXIC TO PLANT LIFE. TEMPORARY SEEDING SCHEDULE SEEDING DATE SEEDING MIXTURE APPLICATION RATE JAN 1 - MAY 1 RYE (GRAIN) 120 LBS/AC KOBE LESPEDEZA 50 LBS/AC MAY 1- AUG 15 GERMAN MILLET 40 LBS/AC AUG 15 - DEC 31 RYE (GRAIN) 120 LBS/AC SOIL AMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/AC GROUND AGRICULTURE LIMESTONE AND 750 LB/AC 10-10-10 FERTILIZER (FROM AUG 15 - DEC 31, INCREASE 10-10-10 FERTILIZER TO 1000 LB/AC). MULCH APPLY 4000 LB/AC STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED ASA MULCH ANCHORING TOOL. MAINTENANCE JAN 1 - AUG 15: REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE, AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. AUG 15 - DEC 31: REPAIR AND REFERTILIZE DAMAGED AREAS IMMEDIATELY. TOP DRESS WITH 50 LB/AC OF NITROGEN IN MARCH. IF IT IS NECESSARY TO EXTEND TEMPORARY COVER BEYOND JUNE 15, OVERSEED WITH 50 LB/AC KOBE LESPEDEZA IN LATE FEBRUARY OR EARLY MARCH. NOTE: USE THE TEMPORARY SEEDING SCHEDULE ONLY WHEN DATE IS NOT CORRECTTO USE THE PERMANENT SEEDING SCHEDULE. 132, I � Co EX. WETLAND , I / I / / / l l f I mO Illi, SEWER EASEMENT IIII I IIIIII I / III 11 1 /lll 1 1 lI I I I I l I I 1 1 l l l / I II II III I l I ISI 11 11�1II III I I I I I I I I I I I l \ l I l / Io j FOREE AY x\���A 98 PC 73 ST 1 1 \ 65AI t 1 II / / // v 75 EF 118 N TEMPORARY,- - 111 INUNDATION ZONE 66 LC ��� 109 I 00O / / i O /X0000 00 000 /opo 60 / / �� 00 03 00 00 /00 61 PC 00 00 00 /CD 00 / X / / /�/ 00 o0 123 Al // /00 /� �� I Q 106 EF MICR 9 POOLi 11 J,/ o� a STORMWATER CONTROL MEASURE/ MAINTENANCE/ACCESS EASEMENT / / // / / / / / I / I I I 1I / / / CO o l I 1 / / /�// _ PROPERTY LINE � �, l // / ' I // 25' PERIMETER BUFFER /l 11 I' l �' � // Il \ �� v / �� I x� 1 GRAPHICSCALE /l 0 10 O0 40 1 inch = 20 ft. STORMWATER CONTROL MEASURE 'C' LANDSCAPE PLAN 1" = 20' FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER (v�I V z�� O UDo FILENAME RYN17010-SWC W ?:wN LU z SCALE Q DC z SHEET J (� Z �C zLU U O O U F_ � O UDo FILENAME RYN17010-SWC CHECKED BY � LU z SCALE W DATE 11. 26. 2018 SHEET Z W 0 O F_ U ,N CARO '�.. '•� SEAL 33782 IR7. 40 •'--tiC I NES ��p REVISIONS N0. DATE PLAN INFORMATION PROJECT NO. RYN-17010 FILENAME RYN17010-SWC CHECKED BY JAA DRAWN BY JSM SCALE 1" = 20' DATE 11. 26. 2018 SHEET STORMWATER CONTROL MEASURE 'C' LANDSCAPE PLAN SW -CLS SUPPLEMENT -EZ FORM COVER PAGE Please indicate the types, quantities and locations of SCMs that will be used on this project: Quantity Location(s) Infiltration System Bioretention Cell Wet Pond 2 SCM A, SCM B Stormwater Wetland 1 SCM C Permeable Pavement Sand Filter Rainwater Harvesting Green Roof Level Spreader -Filter Strip Disconnected Impervious Surface Treatment Swale Dry Pond Designer information for this project: !Name and Title: Jon Aldridge, Senior Project Manager Organization: McAdams 'Street address: 3430 Toringdon Way, Suite 110 City, State, Zip: Charlotte, NC 28277 Phone number(s): 704. 527. 0800 x316 Email: Designer OX R UL SEAL 0 33732 r � Sign tune f Designer Date Project Name: Brookside Address 674 Georgie Street City / Town Troutman Applicant: pany: Nass Cross LLC act: Matthew Wilson ng Address: 7620 Red Bay Lane State, Zip: Parkland, Florida 33076 ie number(s): 609.903.9400 Certification Statement: I certify, under penalty of law: that this Supplement -EZ form and all supporting information were prepared under my direction or supervision; - that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and - that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. I am aware that there are significant penalties for submitting false information including the possibility of fines and imprisonment for knowing violations as well as a report being made to my professional board. frn an ., o, all Cover Page 1 10:17 AM 2/19/2019 WET POND Brookside THE DRAINAGE AREA 7 Drainage area number Sub 2 To SCM A Break down of BUA in the drainage area (both new and existing): Total coastal wetlands area (sq ft) Parking / driveway (sq ft) Total surface water area (sq ft) Sidewalk (sq ft) Total drainage area (sq ft) 781099 sf Roof (sq ft) BUA associated with existing development (sq ft) 5932 sf Roadway (sq ft) Proposed new BUA (sq ft) 297851 sf Other, please specify in the comment box below (sq ft) Percent BUA of drainage area 39% ITotal BUA (sq ft) 303783 sf COMPLIANCE WITH THE APPLICABLE STORMWATER PROGRAM Stormwater program(s) that apply (please specify): Design rainfall depth (in) 1.0 in Minimum Design Criteria standards set forth in the NC DEQ Stormwater Manual Minimum volume required (cu ft) 26038 cf Design volume of SCM (cu ft) 80708 cf GENERAL MDC FROM 02H.1050 #1 Is the SCM sized to treat the SW from all surfaces at build -out? No #7 If applicable, with the SCM be cleaned out after construction? Yes #2 Is the SCM located on or near contaminated soils? No #8 Does the mainetenance access comply with General MDC (8)? Yes #3 What are the side slopes of the SCM (H:V)? 3:1 #9 Does the drainage easement comply with General MDC (9)? Yes #3 Does the SCM have retaining walls, gabion walls or other engineered side slopes? Yes #10 If the SCM is on a single family lot, does the plat comply with General MDC (10)? Yes #4 Are the inlets, outlets, and receiving stream protected from erosion (10 -year storm)? Yes #11 Is there an O&M Agreement that complies with General MDC (11)? Yes #5 Is there a a bypass for flows in excess of the design flow? No 1#12 Is there an O&M Plan that complies with General MDC (12)? Yes #6 What is the method for dewatering the SCM for maintenance? Drawdown Orifice #13 Was the SCM designed by an NC licensed professional? Yes WET POND MDC FROM 02H.1053 #1 Method used SA/DA #6 Width of the vegetated shelf (feet) 6 ft #1 Surface area of the main permanent pool (square feet) 24199 sf #6 Location of vegetated shelf @ Normal Pool #1 Volume of the main permanent pool (cubic feet) 80708 cf #6 Elevation of top of shelf (fmsl) 852.50 it #2 Average depth of the main pool (feet) 3.3 ft #6 Elevation of bottom of shelf (fmsl) 851.50 it #2 Was the vegetated shelf included in the calculation of average depth? Yes #6 Slope of vegetated shelf (H:V) 6:1 #2 Elevation of the bottom of the permanent pool (fmsl) 846 ft #7 Diameter of drawdown orifice (inches) 2.25 in #2 Elevation of the top of the permanent pool (fmsl) 852.00 ft #7 Drawdown time for the temporary pool (hours) 87 hrs #2 Elevation of the top of the temporary pool (fmsl) 852.95 ft #7 Does the orifice drawdown from below the top surface of the permanent pool? Yes #3 Depth provided for sediment storage (inches) 6 in #8 Does the pond minimize impacts to the receiving channel from the 1 -yr, 24 -hr storm? Yes #4 Are the inlet(s) and outlet located in a manner that avoids short-circuiting? Yes #9 Are fountains proposed? No #4 Describe any measures, such as berms or baffles, that will be taken to improve the flow path: #9 If yes, is documentation provided per Wet Pond MDC (9)? #10 Is a trash rack or other device provided to protect the outlet system? Yes #5 Volume of the forebay (cubic feet) 13660 #11 Are the dam and embankment planted in non -clumping turf grass? Yes #5 Is this 15-20% of the volume in the main pool? Yes #11 Species of turf that will be used on the dam and embankment Bermudagrass #5 Depth of forebay at entrance (inches) 48 in #11 Describe the planting plan for the vegetated shelf: #5 Depth of forebay at exit (inches) #5 Does water flow out of the forebay in a non-erosive manner? #5 Clean-out depth for forebay (inches) #5 Will the forebay be cleaned out when the depth is reduced to less than the above? 48 in Yes 6 in Yes Three shallow land species and three shallow water species are specified. Detailed planting instructions are included. ADDITIONAL INFORMATION Please use this space to provide any additional information about this wet pond that you think is relevant to the review: Wet Pond 2 10:17 AM 2/19/2019 WET POND Brookside THE DRAINAGE AREA 2 Drainage area number Sub 2 to SCM B Break down of BUA in the drainage area (both new and existing): Total coastal wetlands area (sq ft) Parking / driveway (sq ft) Total surface water area (sq ft) Sidewalk (sq ft) Total drainage area (sq ft) 663305 sf Roof (sq ft) BUA associated with existing development (sq ft) Roadway (sq ft) Proposed new BUA (sq ft) 318617 sf Other, please specify in the comment box below (sq ft) Percent BUA of drainage area 148% ITotal BUA (sq ft) 318617 sf COMPLIANCE WITH THE APPLICABLE STORMWATER PROGRAM SA/DA Stormwater program(s) that apply (please specify): Design rainfall depth (in) 1.0 in Minimum Design Criteria standards set forth in the NC DEQ Stormwater Manual IMinimurn volume required (cu ft) 26660 cf Is the SCM sized to treat the SW from all surfaces at build -out? No Is the SCM located on or near contaminated soils? No What are the side slopes of the SCM (H:V)? 3:1 Does the SCM have retaining walls, gabion walls or other engineered side slopes? Yes Are the inlets, outlets, and receiving stream protected from erosion (10 -year storm)? Yes Is there a a bypass for flows in excess of the design flow? No What is the method for dewatering the SCM for maintenance? Drawdown Orific 7 POND MDC FROM 02H.1053 Method used SA/DA Surface area of the main permanent pool (square feet) 24506 sf Volume of the main permanent pool (cubic feet) 85164 cf Average depth of the main pool (feet) 3.5 ft Was the vegetated shelf included in the calculation of average depth? Yes Elevation of the bottom of the permanent pool (fmsl) 836 ft Elevation of the top of the permanent pool (fmsl) 841.00 ft Elevation of the top of the temporary pool (fmsl) 841.98 ft Depth provided for sediment storage (inches) 6 in Are the inlet(s) and outlet located in a manner that avoids short-circuiting? Yes Describe any measures, such as berms or baffles, that will be taken to improve the flow path: 0 Is a trash rack or other device provided to protect the outlet system? Yes Volume of the forebay (cubic feet) 14077 Is this 15-20% of the volume in the main pool? Yes Depth of forebay at entrance (inches) 60 in Depth of forebay at exit (inches) 60 in Does water flow out of the forebay in a non-erosive manner? Yes Clean-out depth for forebay (inches) 6 in Will the forebay be cleaned out when the depth is reduced to less than the above? Yes DITIONAL INFORMATION ase use this space to provide any additional information about this wet pond that you think is relevant to the review: If applicable, with the SCM be cleaned out after construction? Yes Does the mainetenance access comply with General MDC (8)? Yes Does the drainage easement comply with General MDC (9)? Yes 0 If the SCM is on a single family lot, does the plat comply with General MDC (10)? Yes 1 Is there an O&M Agreement that complies with General MDC (11)? Yes 2 Is there an O&M Plan that complies with General MDC (12)? Yes 3 Was the SCM designed by an NC licensed professional? Yes Width of the vegetated shelf (feet) 6 ft Location of vegetated shelf @ Normal Pool Elevation of top of shelf (fmsl) 841.50 ft Elevation of bottom of shelf (fmsl) 840.50 ft Slope of vegetated shelf (H:V) 6:1 Diameter of drawdown orifice (inches) 2.25 in Drawdown time for the temporary pool (hours) 88 hrs Does the orifice drawdown from below the top surface of the permanent pool? Yes Does the pond minimize impacts to the receiving channel from the 1 -yr, 24 -hr storm? Yes Are fountains proposed? No If yes, is documentation provided per Wet Pond MDC (9)? 0 Is a trash rack or other device provided to protect the outlet system? Yes 1 Are the dam and embankment planted in non -clumping turf grass? Yes 1 Species of turf that will be used on the dam and embankment Bermudagrass 1 Describe the planting plan for the vegetated shelf: ree shallow land species and three shallow water species are specified. Detailed planting instructions are included Wet Pond 3 10:17 AM 2/19/2019 STORMWATER WETLAND Brookside THE DRAINAGE AREA Drainage area number Total coastal wetlands area (sq ft) Total surface water area (sq ft) 2 To SCM C Break down of BUA in the drainage area (both new and existing): Parking / driveway (sq ft) Sidewalk (sq ft) 7 Total drainage area (sq ft) 378683 sf Roof (sq ft) BUA associated with existing development (sq ft) 4697 sf Roadway (sq ft) Proposed new BUA (sq ft) 101632 sf Other, please specify in the comment box below (sq ft) Percent BUA of drainage area 128% ITotal BUA (sq ft) 106329 sf COMPLIANCE WITH THE APPLICABLE STORMWATER PROGRAM Stormwater program(s) that apply (please specify): IDesign rainfall depth (in) 1.0 in Minimum Design Criteria standards set forth in the NC DEQ Stormwater Manual iminimum volume required (cu ft) 9553 cf Design volume of SCM (cu ft) GENERAL MDC FROM 02H.1050 #1 Is the SCM sized to treat the SW from all surfaces at build -out? No #7 If applicable, with the SCM be cleaned out after construction? Yes #2 Is the SCM located on or near contaminated soils? No #8 Does the mainetenance access comply with General MDC (8)? Yes #3 What are the side slopes of the SCM (H:V)? 3:1 #9 Does the drainage easement comply with General MDC (9)? Yes #3 Does the SCM have retaining walls, gabion walls or other engineered side slopes? No #10 If the SCM is on a single family lot, does the plat comply with General MDC (10)? Yes #4 Are the inlets, outlets, and receiving stream protected from erasion (10 -year storm)? Yes #11 Is there an O&M Agreement that complies with General MDC (11)? Yes #5 Is there a a bypass for Flows in excess of the design flow? No #12 Is there an O&M Plan that complies with General MDC (12)? Yes #6 What is the method for dewatering the SCM for maintenance? Drawdown Orifice #13 Was the SCM designed by an NC licensed professional? Yes STORMWATER WETLAND MDC FROM 02H.1054 #1 Permanent pool elevation (fmsl) 854 ft #8 Total surface area of the shallow water zone at temporary pool (square feet) 2789 sf #1 Temporary pool elevation (fmsl) 855.28 ft #8 SW wetland surface area comprised of shallow water zone at temporary pool (%) 35% #1 Ponding depth (inches) 15.39 in #8 Depth of the shallow water zone below permanent pool (inches) 6 in #2 Is the SW wetland designed for peak attenuation? Yes #8 Elevation of bottom of the shallow water zone (fmsl) 853.50 ft #2 If so, peak attenuation depth (inches) 72.00 in #9 Total surface area of the temporary inundation zone at temporary pool (square feet) 3288 sf #3 Surface area of SW wetland at temporary pool (square feet) 8078 sf #9 SW wetland surface area comprised of temp inundation zone at temp pool (%) 41% #4 Depth of soil amendment (inches) #9 Height of the temporary inundation zone above permanent pool (inches) 9 in #4 Describe how the soil is being amended to promote plant growth: #9 Elevation of bottom of the temporary inundation zone (fmsl) 854 ft #10 Drawdown time for the temporary pool (hours) #10 Does the orifice drawdown from below the top surface of the permanent pool? #11 Does the pond minimize impacts to the receiving channel from the 1 -yr, 24 -hr storm? 77 hrs Yes Yes #6 Are the inlet(s) and outlet located in a manner that avoids short-circuiting? Yes #12 Has a landscaping plan that meets SW Wetland MDC (12) been provided? Yes #6 Describe any measures, such as berms or baffles, that will be taken to improve the flow path: #13 Number of plants per 200 square feet (#) in the shallow water zone: 50 #6 Surface area of the forebay at temporary pool (square feet) #6 Overall SW wetland surface area comprised of forebay at temporary pool (%) 909 sf 11% #13 Describe the planting plan for the shallow water zone: Three shallow water species are specified. Detailed planting instructions are included. #6 Depth of forebay below permanent pool (inches) 36 in #14 Does planting for the temporary inundation zone comply with SW Wetland MDC (14)? Yes #6 Elevation of bottom of forebay (fmsl) 851 ft #14 Describe the planting plan for the temporary inundation zone: #6 Will the forebay be cleaned out when depth is reduced to 15 inches or less? #7 Total surface area of the non-forebay deep pools at temporary pool (square feet) Yes 1092 sf Three temporary inundation species are specified. Detailed planting instructions are included. #7 SW wetland surface area comprised of non-forebay deep pools at temporary pool (%) 14% #15 Are the dam structure and temporary fill slopes planted in non -clumping turfgrass? Yes #7 Depth of non-forebay deep pools below permanent pool (inches) 36 in #16 Will cattails be planted in the wetland? 1#17 No #7 Elevation of bottom of non-forebay deep pools (fmsl) 851 ft Is a trash rack or other device provided to protect the outlet system? Yes ADDITIONAL INFORMATION Please use this space to provide any information about this stormwater wetland that you think is relevant to the review: Wetland 4 10:17 AM 2/19/2019 Operation & Maintenance Agreement Project Name: Project Location: Brookside (Troutman, NC Cover Page Maintenance records shall be kept on the following BMP(s). This maintenance record shall be kept in a log in a known set location. Any deficient BMP elements noted in the inspection will be corrected, repaired, or replaced These deficiencies can affect the integrity of structures, safety of the public, and the pollutant removal efficiency of the BMP(s). The BMP(s) on this project include (check all that apply & correspo Bioretention Cell Quantity: c Dry Detention Basin Quantity: Expires May 11, 2022 Grassed Swale Quantity: Green Roof Quantity: Infiltration Basin Quantity: Infiltration Trench Quantity: Level Spreader/VFS Quantity: Permeable Pavement Quantity: Proprietary System Quantity: Rainwater Harvesting Quantity: Sand Filter Quantity: Stormwater Wetland Quantity: 1 Wet Detention Basin Quantity: 2 Disconnected Impervious Area Present: No User Defined BMP Present: No g O&M tables will Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): Location(s): De aaaea automancali SCM C _ SCM A, SCM B I acknowledge and agree by my signature below that I am responsible for the performance of the maintenance procedures listed for each BMP above, and attached O&M tables. I agree to notify NCDENR of any problems with the system or prior to any changes to the system or responsible party. Responsible Party: Title & Organization: Street address: City, state, zip: Phone number(s): Email: Matthew Wilson Managing Member Nass Crossing LLC 7620 Red Bay Lane Parkland, Florida 33076 609.903.9400 mattwilson9599@gmaii.com Signature: _��/l�,I ��VU�� Date: i 1 27 Zvi s 1. a Notary Public for the State of County of do hearby cer6ify thata 4w W iSOA personally appeared before me this --b day of 1 and acknowledge the due execution of Witness my hand and official seal, ST09RAZ Version 1.4 My commission expires �rw1Z� 11/26/2018 O&M M ual Page 1 of 9 ANITAJTAYLOR c Commission # GG 21542 Expires May 11, 2022 �fFCFF�UQ' Bonded Thrusudp ftbrySiryk ST09RAZ Version 1.4 My commission expires �rw1Z� 11/26/2018 O&M M ual Page 1 of 9 4EW "" ." -N BROOKSIDE Stormwater Impact Analysis & Final Design of Stormwater Control Measures '1 WADAMs BROOKSIDE Troutman, North Carolina Stormwater Impact Analysis & Final Design of Stormwater Control Measures Project Number: Designed By, Date: Revised RYN-17010 Jon Aldridge, PE Kelli Gallt Lauryn Kabrich, EI November 2018 February 2019 .,a<<ff1111����+, .�• N CAR 4r, SEAL r o 33732 i WADAMS r@- ��r °v A 3430 Toringdon Way, Suite 110 Charlotte, North Carolina 28277 NC Lic. # C-0293 2111111 9 MCADAMS STORMWATER IMPACT ANALYSIS GENERAL DESCRIPTION Located northwest of the intersection of Georgie Street and Massey Street in Troutman, North Carolina, is the proposed development known as Brookside. Proposed development on this site will consist of the construction of over 100 residential homes and road extension of York Road along with the associated parking, sidewalks, utility improvements and stormwater control measures The proposed development is located within the Catawba River basin with stormwater runoff from the proposed development draining into an unnamed tributary of Hicks Creek. Per Town of Troutman regulations, stormwater management on this site shall conform to the stormwater management performance standards for development set forth in the Town of Troutman Unified Development Ordinance. The site is required to provide peak runoff control for the 10- year storm. The applicable design requirements are as follows: Sec. 8.11.1 Comprehensive Stormwater Management Plan D. High-density projects shall use wet detention ponds or other structural BMP's, in accordance with the NC DEQ Stormwater BMP Design Manual, to control and treat runoff from the development. If the development also lies within the Watershed Overlay District, additional requirements may apply as to stormwater management (reference Section 3.5). To address applicable stormwater management requirements, three stormwater control measures are proposed to treat runoff and manage peak runoff rates. Please refer to the appropriate section of this report for additional information. CALCULATION METHODOLOGY > Rainfall data for the analysis was taken from the NOAA Atlas 14. Please reference the precipitation information section within this report for additional information. > Using maps contained within the NRCS Web Soil Survey, the on-site soils were determined to be hydrologic soil group (HSG) 'B' soils. Since the method chosen to compute post -development peak flow rates and runoff volumes is dependent upon the soil type, care was taken when selecting the appropriate Soil Conservation Service Curve Number (SCS CN). > A composite SCS Curve Number was calculated for both the pre- and post -development condition for each subbasin using SCS curve numbers and land cover conditions. Land cover conditions for the pre -development condition were taken from available survey and GIS information. Land cover conditions for the post -development condition were taken from the proposed development plan. > The time of concentration was calculated using SCS TR -55 (Segmental Approach, 1986). The Tc flow path was divided into three segments: overland flow, concentrated flow, and channel creating experiences through experience 3430 Toringdon Way, Suite 110, Charlotte, NC 28277 / 704. 527. 0800 9 MCADAMS STORMWATER IMPACT ANALYSIS flow. The travel time was then computed for each segment, from which the overall time of concentration was determined by taking the sum of each segmental time. > PondPack Version V8i was used in determining the pre- & post -development peak flow rates for the 2- and 10 -year storm events, as well as routing calculations for the proposed stormwater management facilities. > The proposed stormwater management facilities are designed in accordance with the Minimum Design Criteria (MDC) standards set forth in the NC DEMLR Stormwater Design Manual. PR1d011-11010[6]2.4:149AV Peak Runoff Control Requirements: The proposed project will result in a significant increase in peak flow rates to downstream properties. To mitigate these impacts, the proposed stormwater management facilities have been sized such that post -development peak flow rates are no greater than pre -development levels in the 10 -year storm event on site. Peak control for the 2 -year storm event was designed to the maximum extent practicable due to grading restrictions and in order to avoid the existing stream buffer; however, a negligible increase in post -development peak flow from pre -development is present. Water Quality Requirements: The proposed facilities are designed in accordance with the NC DEQ Stormwater BMP Design Manual and shall meet applicable water quality requirements. CONCLUSION If the development on this tract is built as proposed within this report, then the requirements set forth in Town of Troutman regulations will be met. However, modifications to the proposed development may require that this analysis be revised. Some modifications that would require this analysis to be revised include: > The proposed site impervious surface exceeds the amount accounted for in this report. > The post -development watershed breaks change significantly from those used to prepare this report. The above modifications may result in the assumptions within this report becoming invalid. The computations within this report will need to be revisited if any of the above conditions become apparent as development of the proposed site moves forward. creating experiences through experience 2 of 2 1 SUMMARY OF RESULTS 2 MISCELANEOUS SITE INFORMATION 3 WATERSHED SOILS INFORMATION A PRECIPITATION DATA 5 CPRE -DEVELOPMENT HYDROLOGIC CALCULATIONS 6 POST -DEVELOPMENT HYDROLOGIC CALCULATIONS 7 STORMWATER CONTROL MEASURE 'A' DESIGN 1 FILES STORMWATER CONTROL MEASURE'B' DESIGN 8 FILES 9 STORMWATER CONTROL MEASURE 'C' DESIGN FILES 10 CULVERT DESIGN CALCULATIONS SUMMARY OF RESULTS BROOKSIDE SUBDIVISION RYN-17010 21MCADAms SUMMARY OF RESULTS Project Name: Brookside Project Numbei RYN-17010 RELEASE RATE MANAGEMENT RESULTS POINT OF ANALYSIS #1 Pre-Dev Post-Dev Return Period [cfs] [cfs] % Increase 2 -Year 1.84 0.98 -47% 10 -Year 9.22 2.80 -70% POINT OF ANALYSIS #2 Pre-Dev Post-Dev Return Period [cfs] [cfs] % Increase 2 -Year 6.12 5.91 -3% 10 -Year 25.10 19.38 -23% Date: 2/13/2019 Calculated By: K. Gallt 21MCADAms SUMMARY OF RESULTS Project Name: Brookside Project Numbei RYN-17010 STORMWATER CONTROL MEASURE'A' SUMMARY Design Impervious Area =7 Design Drainage Area =E26,038 % Impervious =% Water Quality Volume = 3 acres acres cf Main Pool SA Provided = 24,199 Isf Top of Dam = 858.00 ft NWSE = 852.00 ft Average Depth = 3.34 ift Main Pool SA Required = 11,396 sf Main Pool SA Provided = 24,199 Isf Siphon Diameter = 2.25 in Siphon Elevation = 852.00 ft WQV Elevation = 852.97 ft Drawdown Time = 3.63 days Secondary Orifice - Orifice Elevation =P=853.00 853.00Riser Riser = Riser Crest = 856.00 ft Barrel Diameter = 24 in Invert In = 846.00 ft Invert Out =1 845.00 Ift Length = 1 97 Ift % Slope =1 1.03° STORMWATER CONTROL MEASURE'A' ROUTING RESULTS Return Period Inflow [cfs] Outflow [cfs] Max WSE [ft] Freeboard [ft] 2 -Year 37.40 0.24 854.56 3.44 10 -Year 66.79 1.70 856.04 1.96 100 -Year 104.58 27.99 856.67 1.33 Date: 2/13/2019 Calculated By: K. Gallt 21MCADAms SUMMARY OF RESULTS Project Name: Brookside Project Numbei RYN-17010 STORMWATER CONTROL MEASURE'B' SUMMARY Design Drainage Area = 15.23 acres Design Impervious Area = 7.30 acres Impervious = 48.0% Water Quality Volume = 26,622 cf D Top of Dam = NWSE = Average Depth = 10,107 ft ft ft Main Pool SA Provided = 24,506 847.00 841.00 3.48 Main Pool SA Required = 10,107 sf Main Pool SA Provided = 24,506 sf Siphon Diameter =W368 0.24 in Siphon Elevation =ft 10 -Year 65.19 WQV Elevation =ft 845.04 1.96 Drawdown Time =days 96.85 24.60 Secondary Orifice = 1" Orifice Elevation = 842.00 ft Riser = Riser Crest = 845.00 ft Barrel Diameter =W74 in Invert In =ft Invert Out =ft Length =ft % Slope = 2.70% STORMWATER CONTROL MEASURE'B' ROUTING RESULTS Return Period Inflow [cfs] Outflow [cfs] Max WSE [ft] Freeboard [ft] 2 -Year 39.17 0.24 843.62 3.38 10 -Year 65.19 1.54 845.04 1.96 100 -Year 96.85 24.60 845.63 1.37 Date: 2/13/2019 Calculated By: K. Gallt 21MCADAms SUMMARY OF RESULTS Project Name: Brookside Project Numbei RYN-17010 STORMWATER CONTROL MEASURE'C' SUMMARY Design Drainage Area = 8.69 acres Design Impervious Area = z.44 acres Impervious = 28.7% Water Quality Volume = 26,392 cf D Inflow 858.50 ft 24 in 851.00 ft 850.00 ft 57 ft [cfs] [ft] Top of Dam = 860.00 ft NWSE = 854.00 ft Siphon Diameter =W319 26.42 in Siphon Elevation =ft 1.47 100 -Year WQV Elevation =ft 15.96 858.97 Drawdown Time =days Secondary Orifice = 1" Orifice Elevation = 855.30 ft Riser = Riser Crest = Barrel Diameter = Invert In = Invert Out = Length = Inflow 858.50 ft 24 in 851.00 ft 850.00 ft 57 ft % Slope = 1.75% STORMWATER CONTROL MEASURE'C' ROUTING RESULTS Date: 2/13/2019 Calculated By: K. Gallt Inflow Outflow Max WSE Freeboard Return Period [cfs] [cfs] [ft] [ft] 2 -Year 13.30 0.14 857.07 2.93 10 -Year 26.42 1.31 858.53 1.47 100 -Year 44.63 15.96 858.97 1.03 Date: 2/13/2019 Calculated By: K. Gallt MISCELLANEOUS SITE INFORMATION BROOKSIDE SUBDIVISION RYN-17010 2 , l% J�Lr • �n ; ­LWinchester•Rd xr (� z SIl r� y •- i -' WeN 1 :�• ,; , 'r;• "West Ave W W Thomas St E Tho +w♦ , + 16 4. PlcadNy Ln � d � r ,� } • r t .„ ,� ki. zp . "IF -, �~ ss ,tom - Y.�������,' �,� t •.� , Y0., .��1�` E-sri, HERE, Garmin, ©• penStreertMap contrib tors, ource: Esri, • 5 , �,. � DigitaiGlobe, U�GS, AeroGRdD, GeoEye, Earths4ar Geographies, CNE /Airb s D , U DA, IGN, and the GI User Community -- ti. ; �~ SITE • - _ - $ ; ( - �1 c �• �l I Copyright.0.2013N MKa'LGeographic Society, i'cubed, N BROOKSIDE SUBDIVISION " USGS TOPO MAP J 0 1,000 2,000 4,000 PROJECT #: RYN-17010 Feet I inch =2,000 feet TROUTMAN, NORTH CAROLINA 1V1C:ADAM. NC DENR - DIVISON OF WATER RESOURCES .0308 CATAWBA RIVER BASIN 2B .0300 Name of Stream Description Class Class Date Index No. Terrapin Creek From a point 0.5 mile upstream of WS-IV;CA 08/03/92 11-81-(2) mouth to Lake Norman, Catawba River Norwood Creek From source to a point 0.2 mile WS -IV 08/03/92 11-82-(0.5) upstream of Iredell County SR 1328 Bass Creek From source to Norwood Creek WS -IV 08/03/92 11-82-1 Powder Spring Branch From source to Norwood Creek WS -IV 08/03/92 11-82-2 Norwood Creek From a point 0.2 mile upstream of WS-IV;CA 08/03/92 11-82-(3) Iredell County SR 1328 to Lake Norman, Catawba River Hicks Creek From source to a point 0.6 mile WS -IV 08/03/92 11-83-(0.5) upstream of mouth Big Branch From source to a point 0.4 mile WS -IV 08/03/92 11-83-1-(1) upstream of mouth Big Branch From a point 0.4 mile upstream of WS-IV;CA 08/03/92 11-83-1-(2) mouth to Hicks Creek Hicks Creek From a point 0.6 mile upstream of WS-IV;CA 08/03/92 11-83-(2) mouth to Lake Norman, Catawba River Rocky Creek (Youngs Creek) From source to a point 0.6 mile WS -IV 08/03/92 11-84-(1) upstream of mouth Rocky Creek (Youngs Creek) From a point 0.6 mile upstream of WS-IV;CA 08/03/92 11-84-(2) mouth to Lake Norman, Catawba River Stumpy Creek From source to a point 0.5 mile WS -IV 08/03/92 11-85-(1) upstream of mouth Stumpy Creek From a point 0.5 mile upstream of WS-IV;CA 08/03/92 11-85-(2) mouth to Lake Norman, Catawba River Mill Branch From source to Lake Norman, WS-IV,B;CA 08/03/92 11-86 Catawba River Hobbs Creek From source to a point 0.5 mile WS-IV,B 08/03/92 11-87-(1) upstream of mouth Hobbs Creek From a point 0.5 mile upstream of WS-IV,B;CA 08/03/92 11-87-(2) mouth to Lake Norman, Catawba River Cornelius Creek From source to a point 1.1 mile WS -IV 08/03/92 11-88-(1) upstream of mouth Cornelius Creek From a point 1.1 mile upstream of WS-IV;CA 08/03/92 11-88-(2) mouth to Lake Norman, Catawba River Byers Creek From source to 1-77 WS -IV 08/03/92 11-89-(1) Byers Creek From 1-77 to Lake Norman, Catawba WS-IV;CA 08/03/92 11-89-(2) R. Holdsclaw Creek From source to point 0.6 mile WS-IV,B 08/03/92 11-90-(1) upstream of earthen dam Holdsclaw Creek From a point 0.6 mile upstream of WS-IV,B;CA 08/03/92 11-90-(2) earthen dam to Lake Norman, Catawba River McCrary Creek From source to Lake Norman, WS-IV,B;CA 08/03/92 11-91 Catawba River Hobbs Creek From source to Lake Norman, WS-IV,B;CA 08/03/92 11-92 Catawba River 20 1430000 FEET 1440000 FEET 720000 FEET 80°55'0"W 80°54'30"W 80°54'0"W 80°53'30"W 720000 FEET f •j t rya 30 ^, +� M1 Goodman Rd ZONE AE 35°42'30"N ` �g1 35°42'30"N udlr+�,w mal.,, des I -L y Zion Wesley Rd 5� °� Creek �'' TOO WN OO F a � _ ' ,- _' 370► 626 �r° ' °�S Utah Ln � w J N � TOO WN OO F � y �rJ�4r � � ROU MAN ye •o ue 370626 �S�r W Rd 35°42'0"N Winchester Pine Grove Ln IIREDELL COUNTY cardery st y r T T�IMITIXTrnM mnn 4 35°42'0"N vLvl�lv�,viu vi��iLL miu�r�ra a � _ 370313 °� r- - = West Ave ,� �, � ' ���' ����, .+ i ■ r r it r' ��ip► ,. ' ` Sides e4c�i N A , } t h 9h r W Thomas Std E Thomas St yw Picadilly Ln � o� TROUTMAN � Q st u y F°� mor ��� .►�� ,. �� rf� r -, r... Powra'er Elliott Ur eh���i• Tallejt Rd Fr York Rd Bch o A a TOO WN OO F m 5` '�TMROUTMAN ETJ Q4eensbury Ur Fia 370626 S` Barndale U4.r :.� a'� �iC► *r � � eS'Qy `st Caiyih .t`. ... �3 R°bi 0 800 �y�,iii 35°41'30"N ;• `yw � � ROU MAN ETJ °`� 370626 r �m 35°41'30"N F 725 796.4 t Massey ;;t ^h - Gt T�aoe a r ��o Cir h�OhP - '.Av, dE i1r '84 0 Weda�n9tO^�. 710000 FEET 710000 FEET 80°55'0"W 80°54'30"W 80°54'0"W 80°53'30"W 1430000 FEET 1440000 FEET FEMA'S COOPESATING 1W TECHNICAL PASTNEFI This digital Flood Insurance Rate Map (FIRM) was produced through a unique cooperative partnership between the State of North Carolina and the Federal Emergency Management Agency (FEMA). The State of North Carolina has implemented a long term approach to floodplain management to decrease the costs associated with flooding. This is demonstrated by the State's commitment to map flood hazard areas at the local level. As a part of this effort, the State of North Carolina has joined in a Cooperating Technical State agreement with FEMA to produce and maintain this digital FIRM. FLOOD HAZARD INFORMATION NOTES TO USERS SCALE SEE FIS REPORT FOR ZONE DESCRIPTIONS AND INDEX MAP THE INFORMATION DEPICTED ON THIS MAP AND SUPPORTING DOCUMENTATION ARE ALSO AVAILABLE IN DIGITAL FORMATAT HTTP://FRIS.NC.GOV/FRIS Without Base Flood Elevation (BFE) Zone A, V, Hy With BFE or Depth zone AE, AO, AH, VE, AR SPECIAL FLOOD HAZARD AREAS OTHER AREAS OF FLOOD HAZARD 0TH ER AREAS GENERAL STRUCTURES 0TH ER FEATURES Regulatory Floodway -- -- - Coastal Transect Baseline Profile Baseline Hydrographic Feature Limit of Study Jurisdiction Boundary For information and questions about this map, available products associated with this FIRM including historic versions of this FIRM, how to order products or the National Flood Insurance Program in general, please call the FEMA Map Information eXchange at 1 -877 -FEMA -MAP (1-877-336-2627) or visit the FEMA Map Service Center website at http://msc.fema.gov. An accompanying Flood Insurance Study report, Letter of Map Revision (LOMR) or Letter of Map Amendment (LOMA) revising portions of this panel, and digital versions of this FIRM may be available. Visit the North Carolina Floodplain Mapping Program website at http://www.ncfloodmaps.c( or contact the FEMA Map Service Center. Communities annexing land on adjacent FIRM panels must obtain a current copy of the adjacent panel as well as the current FIRM Index. These may be ordered directly from the Map Service Center at the number listed above. For community and countywide map dates refer to the Flood Insurance Study report for this jurisdiction. To determine if flood insurance is available in the community, contact your Insurance agent or call the National Flood Insurance Program at 1-800-638-6620. Base map information shown on this FIRM was provided in digital format by the North Carolina Floodplain Mapping Program (NCFMP). The source of this information can be determined from the metadata available in the digital FLOOD database and in the Technical Support Data Notebook (TSDN). ACCREDITED LEVEE NOTES TO USERS: If an accredited levee note appears on this panel check with your local community to obtain more information, such as the estimated level of protection provided (which may exceed the 1 -percent -annual -chance level) and Emergency Action Plan, on the levee system(s) shown as providing protection. To mitigate flood risk in residual risk areas, property owners and residents are encouraged to consider flood insurance and floodproofing or other protective measures. For more information on flood insurance, interested parties should visit the FEMA Website at http://www.fema.gov/business/nfip/index.shtm. PROVISIONALLY ACCREDITED LEVEE NOTES TO USERS: If a Provisionally Accredited Levee (PAL) note appears on this panel, check with your local community to obtain more information, such as the estimated level of protection provided (which may exceed the 1 -percent -annual -chance level) and Emergency Action Plan, on the levee system(s) shown as providing protection. To maintain accreditation, the levee owner or community is required to submit the data and documentation necessary to comply with Section 65.10 of the NFIP regulations. If the community or owner does not provide the necessary data and documentation or if the data and documentation provided indicates the levee system does not comply with Section 65.10 requirements, FEMA will revise the flood hazard and risk information for this area to reflect de -accreditation of the levee system. To mitigate flood risk in residual risk areas, property owners and residents are encouraged to consider flood insurance and floodproofing or other protective measures. For more information on flood insurance, interested parties should visit the FEMA Website at http://www.fema.gov/business/nfip/index.shtm. LIMIT OF MODERATE WAVE ACTION NOTES TO USERS: For some coastal flooding zones the AE Zone category has been divided by a Limit of Moderate Wave Action (LiMWA). The LiMWA represents the approximate landward limit of the 1.5 -foot breaking wave. The effects of wave hazards between the VE Zone and the LiMWA (or between the shoreline and the LiMWA for areas where VE Zones are not identified) will be similar to, but less severe than those in the VE Zone. Limit of Moderate Wave Action (LiMWA) Map Projection: North Carolina State Plane Projection Feet (Zone 3200) Datum: NAD 1983 (Horizontal), NAVD 1988 (Vertical) 1 inch = 500 feet 1:6,000 0 250 500 1,000 Feet Meters 0 75 150 300 PANEL LO CATO R WILKES COUNTY I YADKIN COUNTY 4804- 4824 14844 4864 4884 \ ----- ------------------ ----------- ±A'8034813 -- ----- -- ---- f f' 4803 4813 4823 4833 4843 4853 4863 4873 4883 4893 \r r- 4802 4812 4822 4832 4842 4852 4862 4872 4882 4892 r /1 4841485148614871 1 1 4800 4820 4880 4840 4850 4860 4870 + ALEXANDER COUNTY 4749 47594769 4779 j DAVIE COUNTY 3788 ' 4708 4728 4788 i 4748 4758 4768 4778 COASTAL BARRIER RESOURCES SYSTEM (CBRS) NOTE L This map may include approximate boundaries of the CBRS for informational purposes only. Flood insurance is not CATAWBA COUNTY available within CBRS areas for structures that are newly built or substantially improved on or after the date(s) indicated on the map. For more information see http://www.fws.gov/habitatconservation/coastal_barrier.html, the FIS Report, or call the U.S. Fish and Wildlife Service Customer Service Center at 1 -800 -344 -WILD. CBRS Area Otherwise Protected Area LINCOLN COUNTY 4766 4786.E "7 06 4716 4726 4736 4746 4756 j i 4725 4735 4745 4755 4765 4775 / u`L'\ 4704 4784 IN 4724 4734 4744 4754 4764 4774 / 4723 4733 4743 4753 4763 4773 4783 4702 4722 4732 4742 4752 4762 4772 4782 01 4711 4721 4731 1 4740 4760,/ 4710 4720 4730 4619 4629 4639 4649 4659 4669 4679 ROWAN COUNTY 4628 4638 4648 4658 4668 4678 4617 4 4637 4647 4657 4667 4677 4686 4616 4626 4636 4646 4656 4666 4676 4615 4,625 4635 4645 4655 4665 4675 4685 4614 4624 4634 4644 465 4 466-4 46.7.4 4.68.4 _--------_ — _ _-_-_ 46134623 1 CABARRUS COUNTY 1 � r 0.2% Annual Chance Flood Hazard, Areas cc of 1% Annual Chance Flood with Average Depth Less Than One Foot or With Drainage NORTH CAROLINA Areas of Less Than One Square Mile zone x Future Conditions 1% Annual Chance Flood Hazard zone x Area with Reduced Flood Risk due to Levee See Notes zone x PANEL 4731 Areas Determined to be Outside the 0.2% Annual Chance Floodplain zone x ------------- Channel, Culvert, or Storm Sewer v) Accredited or Provisionally Accredited FEMA Levee, Dike, or Floodwall 1111111111111 Non -accredited Levee, Dike, or Floodwall BM5510 X North Carolina Geodetic Survey bench mark BM5510 ® National Geodetic Survey bench mark BM5510� Contractor Est. NCFMP Survey bench mark COMMUNITY CID Cross Sections with 1% Annual Chance M Water Surface Elevation (BFE) a- - - - - Coastal Transect -- -- - Coastal Transect Baseline Profile Baseline Hydrographic Feature Limit of Study Jurisdiction Boundary For information and questions about this map, available products associated with this FIRM including historic versions of this FIRM, how to order products or the National Flood Insurance Program in general, please call the FEMA Map Information eXchange at 1 -877 -FEMA -MAP (1-877-336-2627) or visit the FEMA Map Service Center website at http://msc.fema.gov. An accompanying Flood Insurance Study report, Letter of Map Revision (LOMR) or Letter of Map Amendment (LOMA) revising portions of this panel, and digital versions of this FIRM may be available. Visit the North Carolina Floodplain Mapping Program website at http://www.ncfloodmaps.c( or contact the FEMA Map Service Center. Communities annexing land on adjacent FIRM panels must obtain a current copy of the adjacent panel as well as the current FIRM Index. These may be ordered directly from the Map Service Center at the number listed above. For community and countywide map dates refer to the Flood Insurance Study report for this jurisdiction. To determine if flood insurance is available in the community, contact your Insurance agent or call the National Flood Insurance Program at 1-800-638-6620. Base map information shown on this FIRM was provided in digital format by the North Carolina Floodplain Mapping Program (NCFMP). The source of this information can be determined from the metadata available in the digital FLOOD database and in the Technical Support Data Notebook (TSDN). ACCREDITED LEVEE NOTES TO USERS: If an accredited levee note appears on this panel check with your local community to obtain more information, such as the estimated level of protection provided (which may exceed the 1 -percent -annual -chance level) and Emergency Action Plan, on the levee system(s) shown as providing protection. To mitigate flood risk in residual risk areas, property owners and residents are encouraged to consider flood insurance and floodproofing or other protective measures. For more information on flood insurance, interested parties should visit the FEMA Website at http://www.fema.gov/business/nfip/index.shtm. PROVISIONALLY ACCREDITED LEVEE NOTES TO USERS: If a Provisionally Accredited Levee (PAL) note appears on this panel, check with your local community to obtain more information, such as the estimated level of protection provided (which may exceed the 1 -percent -annual -chance level) and Emergency Action Plan, on the levee system(s) shown as providing protection. To maintain accreditation, the levee owner or community is required to submit the data and documentation necessary to comply with Section 65.10 of the NFIP regulations. If the community or owner does not provide the necessary data and documentation or if the data and documentation provided indicates the levee system does not comply with Section 65.10 requirements, FEMA will revise the flood hazard and risk information for this area to reflect de -accreditation of the levee system. To mitigate flood risk in residual risk areas, property owners and residents are encouraged to consider flood insurance and floodproofing or other protective measures. For more information on flood insurance, interested parties should visit the FEMA Website at http://www.fema.gov/business/nfip/index.shtm. LIMIT OF MODERATE WAVE ACTION NOTES TO USERS: For some coastal flooding zones the AE Zone category has been divided by a Limit of Moderate Wave Action (LiMWA). The LiMWA represents the approximate landward limit of the 1.5 -foot breaking wave. The effects of wave hazards between the VE Zone and the LiMWA (or between the shoreline and the LiMWA for areas where VE Zones are not identified) will be similar to, but less severe than those in the VE Zone. Limit of Moderate Wave Action (LiMWA) Map Projection: North Carolina State Plane Projection Feet (Zone 3200) Datum: NAD 1983 (Horizontal), NAVD 1988 (Vertical) 1 inch = 500 feet 1:6,000 0 250 500 1,000 Feet Meters 0 75 150 300 PANEL LO CATO R WILKES COUNTY I YADKIN COUNTY 4804- 4824 14844 4864 4884 \ ----- ------------------ ----------- ±A'8034813 -- ----- -- ---- f f' 4803 4813 4823 4833 4843 4853 4863 4873 4883 4893 \r r- 4802 4812 4822 4832 4842 4852 4862 4872 4882 4892 r /1 4841485148614871 1 1 4800 4820 4880 4840 4850 4860 4870 + ALEXANDER COUNTY 4749 47594769 4779 j DAVIE COUNTY 3788 ' 4708 4728 4788 i 4748 4758 4768 4778 COASTAL BARRIER RESOURCES SYSTEM (CBRS) NOTE L This map may include approximate boundaries of the CBRS for informational purposes only. Flood insurance is not CATAWBA COUNTY available within CBRS areas for structures that are newly built or substantially improved on or after the date(s) indicated on the map. For more information see http://www.fws.gov/habitatconservation/coastal_barrier.html, the FIS Report, or call the U.S. Fish and Wildlife Service Customer Service Center at 1 -800 -344 -WILD. CBRS Area Otherwise Protected Area LINCOLN COUNTY 4766 4786.E "7 06 4716 4726 4736 4746 4756 j i 4725 4735 4745 4755 4765 4775 / u`L'\ 4704 4784 IN 4724 4734 4744 4754 4764 4774 / 4723 4733 4743 4753 4763 4773 4783 4702 4722 4732 4742 4752 4762 4772 4782 01 4711 4721 4731 1 4740 4760,/ 4710 4720 4730 4619 4629 4639 4649 4659 4669 4679 ROWAN COUNTY 4628 4638 4648 4658 4668 4678 4617 4 4637 4647 4657 4667 4677 4686 4616 4626 4636 4646 4656 4666 4676 4615 4,625 4635 4645 4655 4665 4675 4685 4614 4624 4634 4644 465 4 466-4 46.7.4 4.68.4 _--------_ — _ _-_-_ 46134623 1 CABARRUS COUNTY 1 � r MAP NUMBER 3710473100J MAP REVISED 3/18/2008 NORTH CAROLINA FLOODPLAIN MAPPING PROGRAM NATIONAL FLOOD INSURANCE PROGRAM cc FLOOD INSURANCE RATE MAP NORTH CAROLINA ^F� 0 y. PANEL 4731 v 0. a+vo SEG�a v) FEMA cc Panel Contains: L COMMUNITY CID PANEL SUFFIX M IREDELL COUNTY 370313 4731 J TROUTMAN, TOWN OF 370626 4731 J i rrrr� 0 _0 U. co r0 MAP NUMBER 3710473100J MAP REVISED 3/18/2008 WATERSHED SOILS INFORMATION BROOKSIDE SUBDIVISION RYN-17010 3 508BOO 35' 41'47'N 35° 41'25" N Hydrologic Soil Group—Iredell County, North Carolina (Brookside Subdivision) 508900 509000 509100 509200 509300 509400 509500 505800 508900 509000 509100 509200 509300 3 Map Scale: 1:4,830 if printed on A landscape (11"x8.5") sheet. Meters N 0 50 100 200 300 Feet 0 200 400 800 1200 Map projection: Web Mercator Comer coordinates: WGS84 Edge tics: UTM Zone 17N WGS84 G}DA Natural Resources Web Soil Survey Conservation Service National Cooperative Soil Survey 509400 509500 509600 509700 3 N 5091800 i 35° 41'47'N T- 35° 41'25" N 509800 3 N 11/8/2018 Page 1 of 4 Hydrologic Soil Group—Iredell County, North Carolina (Brookside Subdivision) MAP LEGEND Area of Interest (AOI) Area of Interest (AOI) Soils Soil Rating Polygons 0 A 0 A/D 0 B 0 B/D C 0 C/D 0 D Not rated or not available Soil Rating Lines r r A r r A/D r B B/D r r C 0 C/D r r D r r Not rated or not available Soil Rating Points 0 A 0 A/D ■ B ■ B/D MAP INFORMATION p C The soil surveys that comprise your AOI were mapped at 1:12,000. 0 C/D 0 D Warning: Soil Map may not be valid at this scale. p Not rated or not available Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil Water Features line placement. The maps do not show the small areas of Streams and Canals contrasting soils that could have been shown at a more detailed scale. Transportation §_§_+ Rails Please rely on the bar scale on each map sheet for map #%-0 Interstate Highways measurements. US Routes Source of Map: Natural Resources Conservation Service Web Soil Survey URL: Major Roads Coordinate System: Web Mercator (EPSG:3857) Local Roads Maps from the Web Soil Survey are based on the Web Mercator Background projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the ® Aerial Photography Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as of the version date(s) listed below. Soil Survey Area: Iredell County, North Carolina Survey Area Data: Version 23, Sep 10, 2018 Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Apr 8, 2015—Nov 28, 2017 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. UUP Natural Resources Web Soil Survey 11/8/2018 � Conservation Service National Cooperative Soil Survey Page 2 of 4 Hydrologic Soil Group—Iredell County, North Carolina Hydrologic Soil Group Brookside Subdivision USDA Natural Resources Web Soil Survey 11/8/2018 Conservation Service National Cooperative Soil Survey Page 3 of 4 Map unit symbol Map unit name Rating Acres in AOI Percent of AOI CeB2 Cecil sandy clay loam, 2 B 12.4 20.2% to 6 percent slopes, moderately eroded CeC2 Cecil sandy clay loam, 6 B 7.3 11.9% to 10 percent slopes, moderately eroded CgC Cecil -Urban land B 1.5 2.5% complex, 2 to 10 percent slopes CgE Cecil -Urban land B 0.7 1.1% complex, 10 to 25 percent slopes ChA Chewacla loam, 0 to 2 B/D 6.8 11.1% percent slopes, frequently flooded LcB2 Lloyd clay loam, 2 to 6 B 6.3 10.2% percent slopes, moderately eroded LcC2 Lloyd clay loam, 6 to 10 B 4.8 7.8% percent slopes, moderately eroded LcD2 Lloyd clay loam, 10 to B 1.7 2.7% 15 percent slopes, moderately eroded LuC Lloyd -Urban land B 2.7 4.4% complex, 2 to 10 percent slopes MdB Masada fine sandy B 1.8 3.0% loam, 2 to 6 percent slopes PaE Pacolet sandy loam, 15 B 7.0 11.5% to 25 percent slopes PcD2 Pacolet sandy clay B 3.7 5.9% loam, 10 to 15 percent slopes, moderately eroded PcE2 Pacolet sandy clay B 4.8 7.7% loam, 15 to 25 percent slopes, moderately eroded Totals for Area of Interest 61.5 100.0% USDA Natural Resources Web Soil Survey 11/8/2018 Conservation Service National Cooperative Soil Survey Page 3 of 4 Hydrologic Soil Group—Iredell County, North Carolina Description Hydrologic soil groups are based on estimates of runoff potential. Soils are assigned to one of four groups according to the rate of water infiltration when the soils are not protected by vegetation, are thoroughly wet, and receive precipitation from long -duration storms. The soils in the United States are assigned to four groups (A, B, C, and D) and three dual classes (A/D, B/D, and C/D). The groups are defined as follows: Group A. Soils having a high infiltration rate (low runoff potential) when thoroughly wet. These consist mainly of deep, well drained to excessively drained sands or gravelly sands. These soils have a high rate of water transmission. Group B. Soils having a moderate infiltration rate when thoroughly wet. These consist chiefly of moderately deep or deep, moderately well drained or well drained soils that have moderately fine texture to moderately coarse texture. These soils have a moderate rate of water transmission. Group C. Soils having a slow infiltration rate when thoroughly wet. These consist chiefly of soils having a layer that impedes the downward movement of water or soils of moderately fine texture or fine texture. These soils have a slow rate of water transmission. Group D. Soils having a very slow infiltration rate (high runoff potential) when thoroughly wet. These consist chiefly of clays that have a high shrink -swell potential, soils that have a high water table, soils that have a claypan or clay layer at or near the surface, and soils that are shallow over nearly impervious material. These soils have a very slow rate of water transmission. If a soil is assigned to a dual hydrologic group (A/D, B/D, or C/D), the first letter is for drained areas and the second is for undrained areas. Only the soils that in their natural condition are in group D are assigned to dual classes. Rating Options Aggregation Method: Dominant Condition Component Percent Cutoff. None Specified Tie-break Rule: Higher Brookside Subdivision usDA Natural Resources Web Soil Survey 11/8/2018 Conservation Service National Cooperative Soil Survey Page 4 of 4 PRECIPITATION DATA BROOKSIDE SUBDIVISION RYN-17010 10/9/2018 Precipitation Frequency Data Server NOAA Atlas 14, Volume 2, Version 3 -, Location name: Troutman, North Carolina, USA* Latitude: 35.7029°, Longitude: -80.8897° Elevation: 937.52 ft** source: ESRI Maps m y� ** source: USGS POINT PRECIPITATION FREQUENCY ESTIMATES G.M. Bonnin, D. Martin, B. Lin, I Parzybok, M.Yekta, and D. Riley NOAA, National Weather Service, Silver Spring, Maryland PF tabular I PF graphical I Maps & aerials PF tabular PDS -based point precipitation frequency estimates with 90% confidence intervals (in inches)' Average recurrence interval (years) Duration 1 2 5 10 25 50 100 200 500 1000 5 -min 0.378 0.447 0.524 0.580 0.645 0.690 0.733 0.772 0.816 0.849 (0.348-0.411) (0.412-0.488) (0.482-0.571) (0.532-0.630) (0.587-0.701) (0.625-0.751) (0.659-0.799) (0.687-0.843) (0.718-0.898) (0.738-0.938) 10 -min 0.604 0.716 0.840 0.928 1.03 1.10 1.16 1.22 1.29 1.34 (0.556-0.657) (0.660-0.780) (0.772-0.915) (0.850-1.01) (0.936-1.12) (0.996-1.20) 1 (1.05-1.27) 1 (1.09-1.34) 1 (1.14-1.42) 1 (1.16-1.48) 1.39 (1.26-1.51) 0.755 0.900 1.06 1.17 1.30 15 -min 2.72 1 (2.36-3.00) 1 (2.79-3.34) 1 (3.09-3.73) 1 (3.38-4.12) 11 (3.66-4.52) 1 (4.03-5.07) 1(0.696-0.821)]1(0.829-0.980) 9.51 (0.977-1.16) 1 (1.08-1.27) 1 (1.19-1.42) F 4.164.59 1.03 1.24 1.51 1.70 1.93 30 -min (4.07-5.03) ( 4.51-5.71) 1 (4.85-6.25) (0.954-1.13) fl (1.15-1.35) 1 (1.39-1.64) 1 (1.56-1.85) 1 (1.76-2.10) 1.39 (1.26-1.51) 1.47 1.54 1 (1.32-1.60) 11 (1.38-1.69) 1.63 1.68 1 (1.43-1.79) 11 (1.46-1.85) 2.10 (1.90-2.28) 2.25 1 (2.03-2.46) 2.40 1 (2.14-2.63) 2.59 1 (2.28-2.85) 2.72 1 (2.36-3.00) 60 -min 1.29 1.56 1.94 2.21 2.57 2.84 3.11 3.37 3.71 3.97 (1.19-1.40) 1 (1.44-1.70) 1 (1.78-2.11) 1 (2.57-3.09) (2.79-3.38) 11 (3.00-3.68) 1 (3.27-4.08) 11 (3.45-4.38) 2 -hr 1.50 1.81 2.27 (1.38-1.63) 1 (1.67-1.98) 1 (2.08-2.47) 3 -hr 1.60 1.94 2.43 (1.48-1.75) 1 (1.79-2.12) 1 (2.24-2.66) 2.61 3.07 3.42 3.77 4.13 4.60 4.97 (2.39-2.84) 1 (2.79-3.34) 1 (3.09-3.73) 1 (3.38-4.12) 11 (3.66-4.52) 1 (4.03-5.07) (4.29-5.50) 9.51 2.81 3.33 F 4.164.59 5.18 5.64 (2.58-3.07) (3.03-3.63) (3.38-4.09) (3.73-4.55) (4.07-5.03) ( 4.51-5.71) 1 (4.85-6.25) 6 -hr 1.97 2.38 2.98 3.46 4.10 4.62 5.14 5.68 6.43 7.02 (1.82-2.14) 1 (2.20-2.59) 1 (2.75-3.24) 1 (3.18-3.75) 11 (3.75-4.44) 1 (4.19-5.00) 11 (4.62-5.58) 11 (5.05-6.18) 1 (5.62-7.02) 1 (6.06-7.70) 12 -hr 2.36 2.86 3.59 (2.19-2.57) 1 (2.65-3.11) 1 (3.32-3.90) 24 -hr 2.82 3.42 4.32 (2 .62-3.05) (3.17-3.70) ( 4.01-4.68) 4.17 4.96 5.60 6.26 6.95 7.91 8.66 (3.84-4.51) (4.54-5.37) (5.08-6.05) (5.63-6.76) (6.17-7.50) (6.91-8.55) (7.46-9.39) 9.51 10.4 5.03 6.00 6.77 7.57 8.38 (4.64-5.44) (5.52-6.49) (6.22-7.32) (6.92-8.18) (7.64-9.07) (8.62-10.3) (9.38-11.3 ) 2 -day 3.32 4.01 5.02 5.80 ) 6.87 7.71 8.57 9.45 10.6 11.6 (3.08-3.58) (3.72-4.34) (4.65-5.42) (5.37-6.27 (6.34-7.42) (7.10-8.33) (7.86-9.26) 11 (8.64-10.2) 1 (9.69-11.5) 1 (10.5-12.6) 3 -day 3.53 4.25 5.29 (3.29-3.80) fl (3.96-4.59) 1 (4.92-5.71) 4 -day 3.74 4.49 5.56 (3.49 4.02)1 (4.19-4.84) 1 (5.18-5.99) 6.10 7.20 8.07 8.96 9.86 11.1 F 12.1 (5.66-6.57) 11 (6.65-7.76) 7.53 1 (7.44-8.70) 1 (8.23-9.66) 9.34 1 (9.04-10.6) 10.3 1 (10.1-12.0) 1 (11.0-13.1) 6.40 8.43 11.5 12.5 (5.94-6.88) (6.97-8.10) (7.78-9.07) (8.60-10.1) (9.43-11.1) ( 10.6-12.5) 1 (11.4-13.5) 7 -day 4.31 5.15 6.28 7.15 (4.05-4.61) (4.84-5.51) 1 (5.89-6.71) 1 (6.69-7.64) F10 -day 4.95 5.89 7.08 7.99 (4.66-5.27) (5.55-6.27) 1 (6.66-7.53) 1 (7.51-8.50) 8.33 9.25 10.2 11.1 12.4 13.4 (7.77-8.90) (8.61-9.89) 10.1 (9.45-10.9) (10.3-11.9) (11.4-13.3) 11 (12.3-14.4) 9.19 11.1 12.0 13.3 14.2 (8.62-9.79) 1 (9.48-10.8) (10.3-11.8) (11.2-12.8) (12.3-14.2) 1 (13.2-15.2) 20 -day 6.64 7.84 9.26 10.4 ) ( 11.8 ) 13.0 ) ( 14.1 ) ( 15.3 ) ( 16.8 18.0 ) (6.30-6.99) (7.44-8.26) (8.78-9.75) (9.81-10.9 11.2-12.5 (12.2-13.7 13.2-14.9 14.3-16.1 15.7-17.8) (16.7-19.0 30 -day 8.21 9.65 11.1 12.3 (7.84-8.60) (9.22-10.1) 1 (10.6-11.7) 1 (11.7-12.9) 45 -day 10.3 12.1 13.7 14.9 (9.91-10.8) (11.6-12.6) 1 (13.1-14.3) 1 (14.3-15.6) 60 -day 12.3 14.3 16.1 17.5 11 (11.8-12.8) 1 (13.8-14.9) (15.5-16.8) 11 (16.8-1f 13.7 14.8 15.9 17.0 18.4 19.4 (13.1-14.4) 1 (14.1-15.6) 1 (15.1-16.7) 1 (16.1-17.8) 1 (17.3-19.3) 1 (18.3-20.5) 16.5 17.7 18.8 19.9 21.3 22.3 (15.8-17.2) 1 (17.9-19.6) 1 (18.9-20.8) 1 (21.1-23.4) 19.2 20.5 21.7 22.9 24.4 25.6 .4-20.0) (19.6-21.3) (20.8-22.6) (21.9-23.9) (23.3-25.5) 1 (24.3-2E 1 Precipitation frequency (PF) estimates in this table are based on frequency analysis of partial duration series (PDS). umbers in parenthesis are PF estimates at lower and upper bounds of the 90% confidence interval. The probability that precipitation frequency estimates (for a ven duration and average recurrence interval) will be greater than the upper bound (or less than the lower bound) is 5%. Estimates at upper bounds are not iecked against probable maximum precipitation (PMP) estimates and may be higher than currently valid PMP values. refer to NOAA Atlas 14 document for more information. Back to Top PF graphical https:Hhdsc.nws.noaa.gov/hdsc/pfds/pfds_printpage.htmI?lat=35.7029&Ion=-80.8897&data=depth&units=engIish&series=pds 1/4 10/9/2018 Precipitation Frequency Data Server PDS -based depth -duration -frequency (DDF) curves Latitude: 35.70291, Longitude: -80-88971 30 25 --- -- --- --- -- -- 20 c � d CL 'E 10 CL y S 30 25 c = 20 iz m 15 9 CL .� l0 a 5 = -� 0 1 2 5 10 25 50 100 20D 500 1000 Average recurrence interval (years) NDAAAtlas 14, Valu me 2, Version 3 Created {GMT}: Tue Oct 9 19:29:21 2018 Back to Top Maps & aerials Small scale terrain Average recurrence interval (years) — 1 2 — 5 — 1Q 25 50 100 200 500 1000 Duration — "in — 2 -day — 16 -min — 3 -day 15 -min — 4 -day — 30�-min — 7 -day — 60 -min — 10�-eay — 2-nr — 20 -day — 3 -hr — 34 -clay — 6 -hr — 45-tlay — 12 -hr — L L L L L rp rq r4 M rR rR ra M r4 O O O N A4b H A 4 V � O O O Ln O i r I m LQ ry rn v n Duration 30 25 c = 20 iz m 15 9 CL .� l0 a 5 = -� 0 1 2 5 10 25 50 100 20D 500 1000 Average recurrence interval (years) NDAAAtlas 14, Valu me 2, Version 3 Created {GMT}: Tue Oct 9 19:29:21 2018 Back to Top Maps & aerials Small scale terrain Average recurrence interval (years) — 1 2 — 5 — 1Q 25 50 100 200 500 1000 Duration — "in — 2 -day — 16 -min — 3 -day 15 -min — 4 -day — 30�-min — 7 -day — 60 -min — 10�-eay — 2-nr — 20 -day — 3 -hr — 34 -clay — 6 -hr — 45-tlay — 12 -hr — 6o -day — 24 -hr https://hdsc.nws.noaa.gov/hdsc/pfds/pfds_printpage.html?lat=35.7029&Ion=-80.8897&data=depth&units=english&series=pds 2/4 10/9/2018 Precipitation Frequency Data Server 3km In 2mi Large scale terrain nysport' Bristol ohnson City sti Winston-Salem • . [iurham 4, Greensboro • i 1.1.11 Mitchell I •AsheAle NORTH CAROLINA Charlotte Fa}et J 100km f f S 60mi C I1 1 1 T U r' a n n T T TO d Large scale map JSings# .. era Johnson S } instonlem Greensboro North f. Ca Follna arlotte �le — 100km 6 Large scale aerial https://hdsc.nws.noaa.gov/hdsc/pfds/pfds_printpage.html?lat=35.7029&Ion=-80.8897&data=depth&units=english&series=pds 3/4 10/9/2018 Precipitation Frequency Data Server f O 4 Back to Top US Department of Commerce National Oceanic and Atmospheric Administration National Weather Service National Water Center 1325 East West Highway Silver Spring, MD 20910 Questions?: HDSC.Questions@noaa.gov Disclaimer https://hdsc.nws.noaa.gov/hdsc/pfds/pfds_printpage.html?lat=35.7029&Ion=-80.8897&data=depth&units=english&series=pds 4/4 'J MCADAMS Element Details ID 30 Notes Label Troutman 2 year Label 2 year Increment 5.000 min Return Event 2 years End Time 1,440.000 min Start Time 0.000 min Storm Event Depth Type Cumulative 2 year Time Depth Depth Depth Depth Depth (min) (in) (in) (in) (in) (in) 0.000 0.000 0.004 0.007 0.011 0.015 25.000 0.018 0.022 0.026 0.029 0.033 50.000 0.037 0.040 0.044 0.048 0.052 75.000 0.055 0.059 0.063 0.066 0.070 100.000 0.074 0.077 0.081 0.085 0.088 125.000 0.092 0.096 0.099 0.103 0.107 150.000 0.110 0.114 0.118 0.121 0.125 175.000 0.129 0.133 0.136 0.140 0.144 200.000 0.147 0.151 0.155 0.158 0.162 225.000 0.166 0.169 0.173 0.177 0.180 250.000 0.184 0.188 0.191 0.195 0.199 275.000 0.202 0.206 0.210 0.213 0.217 300.000 0.221 0.225 0.228 0.232 0.236 325.000 0.239 0.243 0.247 0.250 0.254 350.000 0.258 0.261 0.265 0.272 0.278 375.000 0.285 0.291 0.298 0.304 0.311 400.000 0.317 0.324 0.330 0.337 0.343 425.000 0.350 0.356 0.363 0.369 0.376 450.000 0.382 0.389 0.396 0.402 0.409 475.000 0.415 0.422 0.428 0.435 0.441 500.000 0.448 0.454 0.461 0.467 0.474 525.000 0.480 0.487 0.493 0.500 0.512 550.000 0.524 0.537 0.549 0.561 0.573 575.000 0.586 0.598 0.610 0.622 0.634 600.000 0.647 0.659 0.671 0.683 0.696 625.000 0.708 0.720 0.730 0.740 0.750 650.000 0.760 0.770 0.780 0.802 0.823 675.000 0.845 0.867 0.888 0.910 0.983 700.000 1.056 1.130 1.203 1.429 1.877 725.000 2.104 2.177 2.250 2.324 2.397 750.000 2.470 2.492 2.513 2.535 2.557 775.000 2.578 2.600 2.610 2.620 2.630 800.000 2.640 2.650 2.660 2.672 2.684 825.000 2.697 2.709 2.721 2.733 2.746 850.000 2.758 2.770 2.782 2.794 2.807 875.000 2.819 2.831 2.843 2.856 2.868 900.000 2.880 2.887 2.893 2.900 2.906 925.000 2.913 2.919 2.926 2.932 2.939 HOWARD K. GALLT RYN 18000.ppc 10/4/2018 'J MCADAMS 2 year Time Depth Depth Depth Depth Depth (min) (in) (in) (in) (in) (in) 950.000 2.945 2.952 2.958 2.965 2.971 975.000 2.978 2.984 2.991 2.998 3.004 1,000.000 3.011 3.017 3.024 3.030 3.037 1,025.000 3.043 3.050 3.056 3.063 3.069 1,050.000 3.076 3.082 3.089 3.095 3.102 1,075.000 3.108 3.115 3.119 3.122 3.126 1,100.000 3.130 3.133 3.137 3.141 3.144 1,125.000 3.148 3.152 3.155 3.159 3.163 1,150.000 3.167 3.170 3.174 3.178 3.181 1,175.000 3.185 3.189 3.192 3.196 3.200 1,200.000 3.203 3.207 3.211 3.214 3.218 1,225.000 3.222 3.225 3.229 3.233 3.236 1,250.000 3.240 3.244 3.248 3.251 3.255 1,275.000 3.259 3.262 3.266 3.270 3.273 1,300.000 3.277 3.281 3.284 3.288 3.292 1,325.000 3.295 3.299 3.303 3.306 3.310 1,350.000 3.314 3.317 3.321 3.325 3.328 1,375.000 3.332 3.336 3.340 3.343 3.347 1,400.000 3.351 3.354 3.358 3.362 3.365 1,425.000 3.369 3.373 3.376 3.380 (N/A) 10 year Label 10 year Increment 5.000 min Return Event 10 years End Time 1,440.000 min Start Time 0.000 min Storm Event Depth Type Cumulative 10 year Time Depth Depth Depth Depth Depth (min) (in) (in) (in) (in) (in) 0.000 0.000 0.006 0.011 0.017 0.023 25.000 0.028 0.034 0.039 0.045 0.051 50.000 0.056 0.062 0.068 0.073 0.079 75.000 0.084 0.090 0.096 0.101 0.107 100.000 0.113 0.118 0.124 0.129 0.135 125.000 0.141 0.146 0.152 0.158 0.163 150.000 0.169 0.174 0.180 0.186 0.191 175.000 0.197 0.202 0.208 0.214 0.219 200.000 0.225 0.231 0.236 0.242 0.248 225.000 0.253 0.259 0.264 0.270 0.276 250.000 0.281 0.287 0.293 0.298 0.304 275.000 0.309 0.315 0.321 0.326 0.332 300.000 0.338 0.343 0.349 0.354 0.360 325.000 0.366 0.371 0.377 0.382 0.388 350.000 0.394 0.399 0.405 0.415 0.424 375.000 0.434 0.444 0.454 0.463 0.473 400.000 0.483 0.492 0.502 0.512 0.522 HOWARD K. GALLT RYN 18000.ppc 10/4/2018 'J MCADAMS 10 year Time Depth Depth Depth Depth Depth (min) (in) (in) (in) (in) (in) 425.000 0.531 0.541 0.551 0.561 0.570 450.000 0.580 0.590 0.599 0.609 0.619 475.000 0.629 0.638 0.648 0.658 0.667 500.000 0.677 0.687 0.697 0.706 0.716 525.000 0.726 0.736 0.745 0.755 0.773 550.000 0.791 0.808 0.826 0.844 0.862 575.000 0.879 0.897 0.915 0.933 0.951 600.000 0.968 0.986 1.004 1.022 1.039 625.000 1.057 1.075 1.092 1.108 1.125 650.000 1.142 1.158 1.175 1.208 1.242 675.000 1.275 1.308 1.342 1.375 1.491 700.000 1.606 1.722 1.837 2.132 2.712 725.000 3.007 3.123 3.238 3.354 3.469 750.000 3.585 3.618 3.652 3.685 3.718 775.000 3.752 3.785 3.802 3.818 3.835 800.000 3.852 3.868 3.885 3.903 3.921 825.000 3.938 3.956 3.974 3.992 4.009 850.000 4.027 4.045 4.063 4.081 4.098 875.000 4.116 4.134 4.152 4.169 4.187 900.000 4.205 4.215 4.224 4.234 4.244 925.000 4.254 4.263 4.273 4.283 4.293 950.000 4.302 4.312 4.322 4.331 4.341 975.000 4.351 4.361 4.370 4.380 4.390 1,000.000 4.399 4.409 4.419 4.429 4.438 1,025.000 4.448 4.458 4.468 4.477 4.487 1,050.000 4.497 4.506 4.516 4.526 4.536 1,075.000 4.545 4.555 4.561 4.566 4.572 1,100.000 4.578 4.583 4.589 4.594 4.600 1,125.000 4.606 4.611 4.617 4.623 4.628 1,150.000 4.634 4.639 4.645 4.651 4.656 1,175.000 4.662 4.668 4.673 4.679 4.684 1,200.000 4.690 4.696 4.701 4.707 4.713 1,225.000 4.718 4.724 4.729 4.735 4.741 1,250.000 4.746 4.752 4.758 4.763 4.769 1,275.000 4.774 4.780 4.786 4.791 4.797 1,300.000 4.803 4.808 4.814 4.819 4.825 1,325.000 4.831 4.836 4.842 4.848 4.853 1,350.000 4.859 4.864 4.870 4.876 4.881 1,375.000 4.887 4.893 4.898 4.904 4.909 1,400.000 4.915 4.921 4.926 4.932 4.938 1,425.000 4.943 4.949 4.954 4.960 (N/A) 25 year Label 25 year Increment 5.000 min Return Event 25 years End Time 1,440.000 min Start Time 0.000 min Storm Event Depth Type Cumulative HOWARD K. GALLT RYN 18000.ppc 10/4/2018 'J MCADAMS 25 year Time Depth Depth Depth Depth Depth (min) (in) (in) (in) (in) (in) 0.000 0.000 0.007 0.013 0.020 0.027 25.000 0.034 0.040 0.047 0.054 0.061 50.000 0.067 0.074 0.081 0.088 0.094 75.000 0.101 0.108 0.115 0.121 0.128 100.000 0.135 0.141 0.148 0.155 0.162 125.000 0.168 0.175 0.182 0.189 0.195 150.000 0.202 0.209 0.216 0.222 0.229 175.000 0.236 0.242 0.249 0.256 0.263 200.000 0.269 0.276 0.283 0.290 0.296 225.000 0.303 0.310 0.317 0.323 0.330 250.000 0.337 0.344 0.350 0.357 0.364 275.000 0.370 0.377 0.384 0.391 0.397 300.000 0.404 0.411 0.418 0.424 0.431 325.000 0.438 0.445 0.451 0.458 0.465 350.000 0.472 0.478 0.485 0.497 0.509 375.000 0.520 0.532 0.544 0.556 0.568 400.000 0.579 0.591 0.603 0.615 0.627 425.000 0.638 0.650 0.662 0.674 0.686 450.000 0.698 0.709 0.721 0.733 0.745 475.000 0.757 0.768 0.780 0.792 0.804 500.000 0.816 0.827 0.839 0.851 0.863 525.000 0.875 0.886 0.898 0.910 0.931 550.000 0.953 0.974 0.996 1.017 1.038 575.000 1.060 1.081 1.103 1.124 1.145 600.000 1.167 1.188 1.209 1.231 1.252 625.000 1.274 1.295 1.317 1.338 1.360 650.000 1.382 1.403 1.425 1.467 1.508 675.000 1.550 1.592 1.633 1.675 1.815 700.000 1.955 2.095 2.235 2.564 3.207 725.000 3.535 3.675 3.815 3.955 4.095 750.000 4.235 4.277 4.318 4.360 4.402 775.000 4.443 4.485 4.507 4.528 4.550 800.000 4.572 4.593 4.615 4.636 4.658 825.000 4.679 4.701 4.722 4.743 4.765 850.000 4.786 4.808 4.829 4.850 4.872 875.000 4.893 4.914 4.936 4.957 4.979 900.000 5.000 5.012 5.024 5.035 5.047 925.000 5.059 5.071 5.083 5.094 5.106 950.000 5.118 5.130 5.142 5.153 5.165 975.000 5.177 5.189 5.201 5.213 5.224 1,000.000 5.236 5.248 5.260 5.272 5.283 1,025.000 5.295 5.307 5.319 5.331 5.342 1,050.000 5.354 5.366 5.378 5.390 5.401 1,075.000 5.413 5.425 5.432 5.438 5.445 1,100.000 5.452 5.459 5.465 5.472 5.479 1,125.000 5.486 5.492 5.499 5.506 5.513 1,150.000 5.519 5.526 5.533 5.540 5.546 1,175.000 5.553 5.560 5.566 5.573 5.580 HOWARD K. GALLT RYN 18000.ppc 10/4/2018 'J MCADAMS 25 year Time Depth Depth Depth Depth Depth (min) (in) (in) (in) (in) (in) 1,200.000 5.587 5.593 5.600 5.607 5.614 1,225.000 5.620 5.627 5.634 5.641 5.647 1,250.000 5.654 5.661 5.668 5.674 5.681 1,275.000 5.688 5.694 5.701 5.708 5.715 1,300.000 5.721 5.728 5.735 5.742 5.748 1,325.000 5.755 5.762 5.769 5.775 5.782 1,350.000 5.789 5.795 5.802 5.809 5.816 1,375.000 5.822 5.829 5.836 5.843 5.849 1,400.000 5.856 5.863 5.870 5.876 5.883 1,425.000 5.890 5.897 5.903 5.910 (N/A) 100 year Label 100 year Increment 5.000 min Return Event 100 years End Time 1,440.000 min Start Time 0.000 min Storm Event Depth Type Cumulative 100 year Time Depth Depth Depth Depth Depth (min) (in) (in) (in) (in) (in) 0.000 0.000 0.008 0.017 0.025 0.034 25.000 0.042 0.050 0.059 0.067 0.076 50.000 0.084 0.092 0.101 0.109 0.118 75.000 0.126 0.134 0.143 0.151 0.160 100.000 0.168 0.176 0.185 0.193 0.202 125.000 0.210 0.218 0.227 0.235 0.244 150.000 0.252 0.260 0.269 0.277 0.286 175.000 0.294 0.303 0.311 0.319 0.328 200.000 0.336 0.345 0.353 0.361 0.370 225.000 0.378 0.387 0.395 0.403 0.412 250.000 0.420 0.429 0.437 0.445 0.454 275.000 0.462 0.471 0.479 0.487 0.496 300.000 0.504 0.513 0.521 0.529 0.538 325.000 0.546 0.555 0.563 0.571 0.580 350.000 0.588 0.597 0.605 0.620 0.636 375.000 0.651 0.667 0.682 0.698 0.713 400.000 0.728 0.744 0.759 0.775 0.790 425.000 0.805 0.821 0.836 0.852 0.867 450.000 0.883 0.898 0.913 0.929 0.944 475.000 0.960 0.975 0.990 1.006 1.021 500.000 1.037 1.052 1.068 1.083 1.098 525.000 1.114 1.129 1.145 1.160 1.187 550.000 1.214 1.242 1.269 1.296 1.323 575.000 1.351 1.378 1.405 1.432 1.459 600.000 1.487 1.514 1.541 1.568 1.596 625.000 1.623 1.650 1.683 1.717 1.750 650.000 1.783 1.817 1.850 1.904 1.958 HOWARD K. GALLT RYN 18000.ppc 10/4/2018 'J MCADAMS 100 year Time Depth Depth Depth Depth Depth (min) (in) (in) (in) (in) (in) 675.000 2.013 2.067 2.121 2.175 2.356 700.000 2.537 2.718 2.899 3.265 3.994 725.000 4.359 4.541 4.722 4.903 5.084 750.000 5.265 5.319 5.373 5.428 5.482 775.000 5.536 5.590 5.623 5.657 5.690 800.000 5.723 5.757 5.790 5.817 5.844 825.000 5.872 5.899 5.926 5.953 5.981 850.000 6.008 6.035 6.062 6.089 6.117 875.000 6.144 6.171 6.198 6.226 6.253 900.000 6.280 6.295 6.311 6.326 6.342 925.000 6.357 6.373 6.388 6.403 6.419 950.000 6.434 6.450 6.465 6.480 6.496 975.000 6.511 6.527 6.542 6.558 6.573 1,000.000 6.588 6.604 6.619 6.635 6.650 1,025.000 6.665 6.681 6.696 6.712 6.727 1,050.000 6.743 6.758 6.773 6.789 6.804 1,075.000 6.820 6.835 6.843 6.852 6.860 1,100.000 6.869 6.877 6.885 6.894 6.902 1,125.000 6.911 6.919 6.927 6.936 6.944 1,150.000 6.953 6.961 6.969 6.978 6.986 1,175.000 6.995 7.003 7.011 7.020 7.028 1,200.000 7.037 7.045 7.053 7.062 7.070 1,225.000 7.079 7.087 7.095 7.104 7.112 1,250.000 7.121 7.129 7.138 7.146 7.154 1,275.000 7.163 7.171 7.180 7.188 7.196 1,300.000 7.205 7.213 7.222 7.230 7.238 1,325.000 7.247 7.255 7.264 7.272 7.280 1,350.000 7.289 7.297 7.306 7.314 7.322 1,375.000 7.331 7.339 7.348 7.356 7.364 1,400.000 7.373 7.381 7.390 7.398 7.406 1,425.000 7.415 7.423 7.432 7.440 (N/A) HOWARD K. GALLT RYN 18000.ppc 10/4/2018 'J MCADAMS I see SolM 100 year 25 year 10 year — 2 year I HOWARD K. GALLT RYN 18000. ppc 10/4/2018 PRE -DEVELOPMENT HYDROLOGIC CALCULATIONS BROOKSIDE SUBDIVISION RYN-17010 TI MCADAMS PRE DEVELOPMENT HYDROLOGIC SUMMARY Project Name: Brookside Date: 11/15/2018 Project Numbe RYN-17010 Calculated By: K. Gallt INPUT SUMMARY Onsite Area [acres] Offsite Area [acres] Total Area Subbasin ID Impervious Open 1 Wooded 1 Pond Total Impervious Open 1 Wooded 1 PondTotal [acres] SCS CN Tc [min] 1 1 0.00 1 0.26 1 13.34 1 0.00 1 13.60 1 0.03 1 0.52 1 0.32 11 0.00 0.87 14.47 55 19.82 'J MCADAMs PRE DEVELOPMENT HYDROLOGIC CALCULATIONS Project Name: Brookside Date: 11/15/2018 Project Numbei RYN-17010 Calculated By: K. Gallt Subbasin ID: 1 SCS CURVE NUMBER (REF: TR -55 and NRCS Web Soil Survey). HSG Impervious Open Wooded Pond A 98 39 30 100 B 98 61 55 100 C 98 74 70 100 D 98 80 77 100 HSG 'A' = 0% HSG 'B' = 100% HSG 'C' = 0% HSG 'D' = 0% Cover Composite Condition SCS CN Comments Impervious 98 Open 61 Assume good condition Wooded 55 Assume good condition Pond 100 WATERSHED BREAKDOWN Composite Area Area Contributing Area SCS CN [sf] [acres] Comments Onsite Impervious 98 0 0.00 ft ft ft ft ft/ft ft/sec minutes Onsite Open 61 11,199 0.26 Assume good condition Onsite Wooded 55 581,147 13.34 Assume good condition Onsite Pond 100 0 0.00 17.66 Offsite Impervious 98 1,176 0.03 Offsite Open 61 22,829 1 0.52 Assume good condition Offsite Wooded 55 13,853 6_._321 Assume good condition Offsite Pond 100 0 0.00 1 - Total Area = 630,204 sf = 14.47 acres Composite SCS CN = 55 % Impervious = 0.19% TIME OF CONCENTRATION (REF: SCS Segmental Approach, TR -55). Segment 1: Overland Flow Length = Upstream Elevation = Downstream Elevation = Height = Slope = Manning's n = P (2-year/24-hour) = Segment Time = Segment 2: Concentrated Flow ft Length = ft Upstream Elevation = ft Downstream Elevation = ft Height = ft/ft Slope = wooded -light underbrush Paved? inches (Troutman, NC) Velocity = minutes Segment Time = ft ft ft ft ft/ft ft/sec minutes 100 617 887.50 884.50 884.50 830.50 3.00 54.00 0.0300 0.0875 0.40 No 3.42 4.77 17.66 2.15 Time of Concentration = 19.82 minutes SCS Lag Time = 11.89 minutes 'J MCADAMs PRE DEVELOPMENT HYDROLOGIC CALCULATIONS Project Name: Brookside Project Numbe RYN-17010 Subbasin ID: 2 SCS CURVE NUMBER (REF: TR -55 and NRCS Web Soil Survey). HSG Impervious Open Wooded Pond A 98 39 30 100 B 98 61 55 100 C 98 74 70 100 D 98 80 77 100 HSG 'A' =WO% Composite HSG 'B' = Condition HSG 'C' = Comments HSG 'D' = 98 Cover Composite 1,928 Condition SCS CN Comments Impervious 98 2.82 Oen 61 Assume good condition Wooded 55 Assume good condition Pond 100 0 WATERSHED BREAKDOWN Date: 11/28/2018 Calculated By: K. Gallt Composite Area Area Contributinq Area SCS CN fsfj facresl Comments Onsite Impervious 98 1,928 0.04 100 Onsite Open 61 122,851 2.82 Assume good condition Onsite Wooded 55 1,800,750 41.34 Assume good condition Onsite Pond 100 0 0.00 0.40 Offsite Impervious 98 17,505 0.40 Segment Time = 1 Offsite Open 61 79,096 1.82 Assume good condition Offsite Wooded 55 26,596 0.61 Assume good condition Offsite Pond 100 0 0.00 Total Area = 2,048,726 sf = 47.03 acres Composite SCS CN = 56 % Impervious = 0.95% TIME OF CONCENTRATION (REF: SCS Segmental Approach, TR -55). Segment 1: Overland Flow Segment 2: Concentrated FI( Length = 100 ft Length = Upstream Elevation = 900.00 ft Upstream Elevation = Downstream Elevation = 898.00 ft Downstream Elevation = Height = 2.00 ft Height = Slope = 0.0200 ft/ft Slope = Manning's n = 0.40 wooded -light underbrush Paved? P (2-year/24-hour) = 3.42 linches (Troutman, NC) Velocity = Segment Time = 1 20.77 Iminutes Segment Time = 856.00 ft 42.00 ft 0.0545 ft/ft No 3.77 ft/sec 3.41 minutes Segment 3: Channel Flow Length = Upstream Elevation = Downstream Elevation = Height = Slope = Manning's n = Flow Area = Wetted Perimeter = Channel Velocity = Segment Time = Time of Concentration = SCS Lag Time =1 Segment 4: Channel Flow ft Length = ft Upstream Elevation = ft Downstream Elevation = ft Height = ft/ft Slope = natural channel Manning's n = sf (assume 1'x1' channel) Flow Area = If (assume 1'x1' channel) Wetted Perimeter = ft/sec Channel Velocity = minutes Segment Time = minutes Iminutes 2132 836.00 817.50 18.50 0.0087 0.045 49 21 5.43 6.55 ft ft ft ft ft/ft major stream sf (assume 7'x7' channel) If (assume 7'x7' channel) ft/sec minutes 177 856.00 836.00 20.00 0.1130 0.045 1 3 5.35 0.55 31.28 18.77 'J MCADAMS Scenario: Pre 2 year BROOKSIDE K. GALLT RYN 17010.ppc 11/14/2018 'J MCADAMS Subsection: Master Network Summary Catchments Summary Label Scenario Return Hydrograph Time to Peak Peak Flow Event Volume (min) (ft3/s) (years) (ac -ft) SUB 1 Pre 2 year 2 0.365 753.000 1.84 SUB 1 Pre 10 year 10 1.147 734.000 9.22 SUB 2 Pre 2 year 2 1.300 758.000 6.12 SUB 2 Pre 10 year 10 3.941 749.000 25.10 Node Summary Label Scenario Return Hydrograph Time to Peak Peak Flow Event Volume (min) (ft3/s) (years) (ac -ft) POA 1 Pre 2 year 2 0.365 753.000 1.84 POA 1 Pre 10 year 10 1.147 734.000 9.22 POA 2 Pre 2 year 2 1.300 758.000 6.12 POA 2 Pre 10 year 10 3.941 749.000 25.10 BROOKSIDE K. GALLT RYN 17010.ppc 11/14/2018 P� OA I –AVON AVE- k.a. ONCHESTER ROAD - PB PG 34) 50'.�BLIC RAW �] - __j_ — I r■■■■■■■■■■■■ I I <�_ � I ■■■ ■■ ■■■■ ■ �0, ■■I■�■■■was ■■.�L■■■■.� \ I 'I •~• L \ IIIA \ � — l • � / _)/ / J --�� / ♦i'♦ \ � \ \ � IIII/ \\111111111 111111 �i \ 1 � \ \ \ \ --,--, \�► lI ( // � f J _— _" >i -(\ \ ' I \ II(/ I1 IIIIIIIIIII( �\ \ -4 j7T77 FITI-17 \11 I II Ip �1 I� > S1 �( I S2 ^\ Il \ \ 1 � / \ _ • \ � > r I( Illi �\ I I ((/ \\ ) �/ )III/IIIIIIIIIIIIIIIIII 11\ / I � -- \ � l � 1 • / � 1 I � � I I I 1 l l 1 \ �� � � //^ �1 /- / �\ / / \ r��/l I /�i�, 1/te�(IIIIIIIIIII11111\I `1111 II I 11111 \\ l 111 1 (� 1 �,; ` �� / / I • ( / ( I� — \ J\ J r 5� / 1 � / ! � - _ f --5 t/ // �. � ��li� / IIII \ t \, \ �� 1 �� � \ �J- •/L J�l" � � /� � // Y0 KSS 0 SUB 1l/� / PU CR \ cJ — / I • ,1 // / )r/ —i ='J/i//i//�/jlr)I�IIII\ 111 IIII 1 l 1// I\—c' AREA = 14.47 AC ( ) jam/ \/ /�/ J�ii'/ /�j ��%'(J / /J�ll l(��� J� ///�r�/�//�_/ IIS/111\ �(/J VIII (J 1/l , L II I 1 V_ ) / > ( �) • / ^ / / /1 / / / — J---1, (/ r i / J /J /l ( J/ I( I �/ ��/�// /(— � ��(I/C / / ✓ J1�(//JL \ I I ( 1 C /V ( ((,(J/�/llll S ( \ \ l I ■ /i / �' ) ,�' /(III/ sl( ) IJ J^ J II (/ ■ �� / I I / — r / / / �J ti / 1(/111I�\I IIIQI I1 �I �j, / / (1�� 1111// f ( / �)�,I � J���lllll Iljl//(c V I� / I v v V A \ ■�/ Ill(I II 1 v//II IIII S3:�rIII r I IIII`— 111 III ���� \��� J\ / / � �� _-�� � =� II1J �I� \ �\ \\l\I II T/ (�• / �r ) / � ) l l ( ��\\ l ) l l // /(it ��� JJ� c— _—�����J�J�I/�/�%�// I II 1111111/ //IF \f � -'�/ J ( ii/1/ f//// �� mfr _j Ji ��i�/// I \ \ /alt ) •L/ — /�� > l rf/ I// // /// r / Q E N 1 1/ (/ / / /� / \ ) • /!>I� PU LIC \ \ 1 > (/ ),, l / I ( ) ) \ • /(� // S / J / i%j/ii ���� ( I / /J / I �W \ \ 1 11 J // J < > / / I ♦�°'� / ( SUB 2 / r /� / / / / �� - lJ)l/ 1111 �� / /ll I \ / l l / I SS S -// / l � \ � � //r / ( >/� � I ♦ � ��L �' / J l/// /r) /I j/ AREA = 47 03 AC \ �� J / t \ _ / ll /// lJ( , ♦ /-1 —. II 1 /� / /// � j / l / 1 ti \ `� � � l � / < • -- � I �, � � / � � / \ �/ 1 \ • �/ / / �� �/ / //�//� 1) 1 � � I I I 1 / / l J < < ♦` / / / / / / /// ) r /ice ( l l l I I I l > / // /// / / 1111 f �' J � n / �' / / / / / / / / %/ /%// /// _ / // / r I � iii ) /1�� \LfS2 1 /J % i / / /// j�� ////l \\ 1 \1 \ \ \ \ \1 1 \ I I \ / 1 r✓°� / / / / 1111// ///�/ �`//, ,"� \\ 1\\\\�\ll I VIII) \\ 1 \ ) I \� / ) I �� �1 ■ / �,.////� (�/i�l\\\\ \ l//i/l�� II ll -1 / �S \ \\ \� `I ( 1 1 ■ / / / l J— // / i/�/� 1/ fir/ // /// �� ���\ \ l / // // LEy \ \ 1 l I /44/ /// / �� // / p 1111\ \\ \\ VIII\ � �) 1 I I I � � 1 ■ J J / I / � /////� �j // /// �/C //Jsl(I 1111 Il I)\\ \ \\J�\ll [�1 � \ I )1 \I�� > ■ � � ��( / 5 r —// J / / ///�'/// G.1 11111\ 1////�////(/��J ,�l // l 1 I \ I 1 \ (\ c / �� < ■ / / — / i i JJJI VIII j/i/iii \ = 1 1 \ ( \ ( \ l ■ / i J J / /, — / // /� J / /i/ iJ/ //r S4 r- \\\\\ /r/�/// �! /i/% t��/i%��%i �� / / //i//�/ / //��//�/ ///( J 1111 III \ 1\ I ( 111 >I I l < 1 l )) _j \, 111(1\I\\t�i11 �I \� �) J 1 1 / (II \ ) 11 ) I / ` 1 I I l ♦ / l / / // 1111 / ///� /l/ (// (/ //� =�ii��� ��ll / /J // / / �/ / // / / // /tel/ ////jlJlllll/r f����=,� / /� i/�\ // ( r /// / / /(// /�// ,T/SJII(ll 46 \ \ \ \ lv 11 1( I l ( I /l ) ) j � ♦ / /I � J///i/// r//�/) i//// ��j�j�/_//%/�l / \ \ 11111 \ 1 \ I /� I) I / 1) / / / / / > / / > ♦� ��// (� �r / / ; / � �� ,� I I \ \ III\1 (I/ //I J� ♦ ,� /////J t/ %v��_��\\\��i \III \ / ////l/jl/ /// �/ \ \ I ll�lll/// /�J/�� `` �-'/ //i/ r 1\\ \ \ \ \ I /// 1111///\\\�� _ _ 1111// I / I II J I J( / ♦ /02 //iii IIII/11/ / l 1 // �)) / ♦ �� / ��/ �J/ /'' �/ // // 1111 /// / \\\ �\1�\ \ \ \ \\\ ///J r� ��// moi/ r�� \ I / //—'�/ t I / / / I �I� / / I I / \ ♦ / � �/ / /i / //�,///JJI l _ �—/ //--� � 1 1\\\\\\\\; �� // / / ��//i 11 r� ��/ /// / //� -- \� �/l II l t/ (( \\ ) \\\\\\\ \ 1 /// 1 (J �// l / I I I I ! I \ / �►��� / f'�j //�// j� �/ �J/�i,���1_ \Ill/ /ice= /ii� l I ) �( ✓ ���� r ! /� ��/ti //�// / ��/�i�/%�\�/l i 5 ) / � � -- � � � _, i --/„J //�//moi/> J > \II1 ((� / \ ■ �\_— // ///�� /� /-� / /, / //J / %i/�i�%�;;��I N ) > \ j//(( / J 1\ ( /i /J / ♦ // /// // \ I I 1\1 / / J i 1111 // /////� j // /// / / / // / / i /l l� ✓ %— L��� J > I I ` 1 �♦ s �� / / /ill jai/ (! �// /// I l of ♦ / % / i / / / / / 1111/ //� I l // / / /i / / %%1111/ //� i �/ / / / _ / / / \ / igr 55 / / / 1111 l/� / / \ 1111 / / //////%// i // / /�/ J �S� / /1lr�es� \v�\\�� (a 0 i / _ j — © /%D//// / .�A��/i/�\��I\\���/..////�/� POA 2 OS / �J J 10 M SSEY SF RIA LE- IDTH PUB W PB 61, PG 64 I J— IO PROPERTY LINE SITE AREA = 57.80 AC FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION MICADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT LAND PARTNERS OF AMERICA, LLC 235 APOLLO BEACH BLVD, SUITE 307 APOLLO BEACH, FL 33572 M, lD z�00 OFU- 00 N W 3:w LI 1 Q Q DC z Z J U z W U 0 0 (D 2 OFU- 00 � � z W Q Z 0 U REVISIONS N0. DATE PLAN INFORMATION PROJECT NO. RYN-17010 FILENAME RYN17010-PRE CHECKED BY JAA DRAWN BY KRG SCALE 1"=100' DATE 11. 26. 2018 SHEET PRE -DEVELOPMENT DRAINAGE AREA MAP PRE POST -DEVELOPMENT HYDROLOGIC CALCULATIONS BROOKSIDE SUBDIVISION RYN-17010 'J MCADAMs POST DEVELOPMENT HYDROLOGIC SUMMARY Project Name: Brookside Project Numbei RYN-17010 INPUT SUMMARY Date: 2/13/2019 Calculated By: K. Gallt Onsite Area [acres] i Offsite Area [acres] I Total Area Subbasin ID Impervious Open I Wooded I Pond I Total I Impervious I Open I Wooded I Pond Total [acresl SCS CN I Tc [minl 1 0.15 0.99 0.70 0.00 1.83 0.00 0.00 0.00 0.00 0.00 1.83 62 9.96 2 -To SCM A 6.84 8.25 0.00 0.56 15.64 0.14 1.36 0.79 0.00 2.29 17.93 76 5.00 2 -To SCM B 7.31 7.35 0.00 0.56 15.23 0.00 0.00 0.00 0.00 0.00 15.23 80 5.00 2 -To SCM C 2.33 4.83 0.76 0.11 8.03 0.11 0.48 0.07 0.00 0.66 8.69 71 5.00 2 -Bypass 0.99 6.45 9.63 0.00 17.07 0.20 0.55 0.00 0.00 0.75 17.82 60 16.99 Totals 17.62 27.86 11.09 1.23 57.80 0.44 2.39 0.86 0.00 3.70 61.50 91MCADAMS POST DEVELOPMENT HYDROLOGIC CALCULATIONS Project Name: Brookside Project Numbei RYN-17010 Subbasin ID: 1 SCS CURVE NUMBER (REF: TR -55 and NRCS Web Soil Survey). HSG Imnervinus Onan Wnnded Pnnd A 98 39 30 100 B 98 61 55 100 C 98 74 70 100 D 98 80 77 100 HSG 'A' =ffl0% 98 HSG 'B' = 61 Assume good condition HSG'C'= 55 Assume good condition HSG'D'= 100 Cover Composite Cnnditinn SCS (;N (nmmPntc Impervious 98 Oen 61 Assume good condition Wooded 55 Assume good condition Pond 100 ONSITE IMPERVIOUS BREAKDOWN Imp per Lot Imp Area Contributing Area # of Lots [SfI Isf! Lot Impervious 1.75 3,650 6,388 Measured Impervious - - 0 Total Onsite Impervious Area = 6,388 sf WATERSHED BREAKDOWN Date: 2/13/2019 Calculated By: K. Gallt Composite Area Area Cnntrihutinn Area SCS CN fcfl larrecl Cnmmentc Onsite Impervious 98 6,388 0.15 Onsite Open 61 43,088 0.99 Assume good condition Onsite Wooded 55 30,323 0.70 Assume good condition Onsite Pond 100 0 0.00 Offsite Impervious 98 0 0.00 Offsite Open 61 0 0.00 Assume good condition Offsite Wooded 55 0 0.00 Assume good condition Offsite Pond 100 0 0.00 Total Area =a8d sf =acres Composite SCS CN = % Impervious = TIME OF CONCENTRATION (REF: SCS Segmental Approach, TR -55). Segment 1: Overland Flow Length = Upstream Elevation = Downstream Elevation = Height = Slope = Manning's n = P (2-year/24-hour) = Segment Time = 56 Segment 2: Concentrated Flow ft Length = ft Upstream Elevation = ft Downstream Elevation = ft Height = ft/ft Slope = dense grass Paved? inches (Troutman, NC) Velocity = minutes Segment Time = Upstream Elevation = ft ft ft ft ft/ft ft/sec minutes 100 206 865.50 860.00 860.00 832.00 5.50 28.00 0.0550 0.1359 0.24 No 3.42 5.95 9.21 0.58 Segment 3: Channel Flow Length = 56 ft Upstream Elevation = 832.00 ft Downstream Elevation = 830.50 ft Height = 1.50 ft Slope = 0.0268 ft/ft Manning's n = 0.045 natural channel Flow Area = 9 sf (assume 3'x3' channel) Wetted Perimeter = 9 If (assume 3'x3' channel) Channel Velocity = 5.42 ft/sec Segment Time = 0.17 minutes Time of Concentration = 9.96 minutes SCS Lag Time =1 5.98 Iminutes 21MCADAMS POST DEVELOPMENT HYDROLOGIC CALCULATIONS Project Name: Brookside Project Numbei RYN-17010 Subbasin ID: 2 -To SCM A SCS CURVE NUMBER (REF: TR -55 and NRCS Web Soil Survey). HSG Imnervious Onen Wooded Pond A 98 39 30 100 B 98 61 55 100 C 98 74 70 100 D 98 80 77 100 HSG 'A' =WO% HSG 'B' = HSG 'C' = HSG 'D' = Cover Composite Condition SCS CN Comments Impervious 98 1 - Open 61 Assume good condition Wooded 55 Assume good condition Pond 100 ONSITE IMPERVIOUS BREAKDOWN Imp per Lot Imp Area Contributing Area # of Lots [sfj [sfj Lot Impervious 52.00 3,650189,800 61 Measured Impervious - 108,051 Total Onsite Impervious Area = 297,85T sf WATERSHED BREAKDOWN Date: 2/13/2019 Calculated By: K. Gallt Composite Area Area Contributing Area SCS CN rsfl facresl Comments Onsite Impervious 98 297,851 6.84 Onsite Open 61 359,209 8.25 Assume good condition Onsite Wooded 55 0 0.00 Assume good condition Onsite Pond 100 24,199 0.56 Offsite Impervious 98 5,932 0.14 Offsite Open 1 61 59,404 1 1.36 1 Assume good condition Offsite Wooded 55 34,504 0.79 Assume good condition Offsite Pond 100 0 0.00 Total Area = 781,099 sf = 17.93 acres Composite SCS CN = 76 % Impervious = 38.89% TIME OF CONCENTRATION (REF: SCS Segmental Approach, TR -55). Time of Concentration = 5.00 minutes SCS Lag Time = 3.00 minutes 21MCADAMS POST DEVELOPMENT HYDROLOGIC CALCULATIONS Project Name: Brookside Project Numbei RYN-17010 Subbasin ID: 2 -To SCM B SCS CURVE NUMBER (REF: TR -55 and NRCS Web Soil Survey). HSG Impervious Oen Wooded Pond A 98 39 30 100 B 98 61 55 100 C 98 74 70 100 D 98 80 77 100 HSG 'A' = Imp Area HSG 'B' = HSG 'C' = TO% HSG 'D' = Cover Composite Condition SCS CN Comments Impervious 98 1 - Open 61 Assume good condition Wooded 55 Assume good condition Pond 100 ONSITE IMPERVIOUS BREAKDOWN Imp per Lot Imp Area Contributing Area # of Lots [sf] [sf] Lot Impervious 59.25 3,650216,263 61 Measured Impervious - 102,354 Total Onsite Impervious Area = 318,617 sf WATERSHED BREAKDOWN Date: 2/13/2019 Calculated By: K. Gallt Composite Area Area Contributing Area SCS CN [sf] [acres] Comments Onsite Impervious 98 318,617 7.31 Onsite Open 61 320,183 7.35 Assume good condition Onsite Wooded 55 0 0.00 Assume good condition Onsite Pond 100 24,506 0.56 Offsite Impervious 98 0 0.00 Offsite Open 61 0 0.00 Assume good condition Offsite Wooded 55 0 0.00 Assume good condition Offsite Pond 100 0 0.00 Total Area = 663,305 sf = 15.23 acres Composite SCS CN = 80 % Impervious = 48.03% TIME OF CONCENTRATION (REF: SCS Segmental Approach, TR -55). Time of Concentration = 5.00 minutes SCS Lag Time = 3.00 minutes 21MCADAMS POST DEVELOPMENT HYDROLOGIC CALCULATIONS Project Name: Brookside Project Numbei RYN-17010 Subbasin ID: 2 -To SCM C SCS CURVE NUMBER (REF: TR -55 and NRCS Web Soil Survey). HSG Imnervious Onen Wooded Pond A 98 39 30 100 B 98 61 55 100 C 98 74 70 100 D 98 80 77 100 HSG 'A' =WO% HSG 'B' = HSG 'C' = HSG 'D' = Cover Composite Condition SCS CN Comments Impervious 98 1 - Open 61 Assume good condition Wooded 55 Assume good condition Pond 100 ONSITE IMPERVIOUS BREAKDOWN Imp per Lot Imp Area Contributing Area # of Lots [sfj [sfj Lot Impervious 18.50 3,65067,525 61 Measured Impervious 1 34,107 Total Onsite Impervious Area =1 101,632 sf WATERSHED BREAKDOWN Date: 2/13/2019 Calculated By: K. Gallt Composite Area Area Contributing Area SCS CN rsfl facresl Comments Onsite Impervious 98 101,632 2.33 Onsite Open 61 210,346 4.83 Assume good condition Onsite Wooded 55 33,221 0.76 Assume good condition Onsite Pond 100 4,790 0.11 Offsite Impervious 98 4,697 0.11 Offsite Open 1 61 21,074 1 0.48 Assume good condition Offsite Wooded 55 2,923 0.07 Assume good condition Offsite Pond 100 0 0.00 Total Area = 378,683 sf = 8.69 acres Composite SCS CN = 71 % Impervious = 28.08% TIME OF CONCENTRATION (REF: SCS Segmental Approach, TR -55). Time of Concentration = 5.00 minutes SCS Lag Time = 3.00 minutes 91MCADAMS POST DEVELOPMENT HYDROLOGIC CALCULATIONS Project Name: Brookside Project Number RYN-17010 SubbasinID: 2 -Bypass SCS CURVE NUMBER (REF: TR -55 and NRCS Web Soil Survey). HSG Imnervinus Onan Wnnded Pnnd A 98 39 30 100 B 98 61 55 100 C 98 74 70 100 D 98 80 77 100 HSG 'A' =ffl0% 98 HSG 'B' = 61 Assume good condition HSG'C'= 55 Assume good condition HSG'D'= 100 Cover Composite Cnnditinn SCS (;N (nmmPntc Impervious 98 Oen 61 Assume good condition Wooded 55 Assume good condition Pond 100 ONSITE IMPERVIOUS BREAKDOWN Imp per Lot Imp Area Contributing Area # of Lots [SfI Isf! Lot Impervious 5.50 3,650 20,075 Measured Impervious - 23,052 Total Onsite Impervious Area = 43,127 sf WATERSHED BREAKDOWN Date: 2/13/2019 Calculated By: K. Gallt Composite Area Area Cnntrihutinn Area SCS CN fcfl larrecl Cnmmentc Onsite Impervious 98 43,127 0.99 17.82 Onsite Open 61 280,796 6.45 Assume good condition Onsite Wooded 55 419,619 9.63 Assume good condition Onsite Pond 100 0 0.00 Offsite Impervious 98 8,678 0.20 Offsite Open 61 23,841 0.55 Assume good condition Offsite Wooded 55 0 0.00 Assume good condition Offsite Pond 100 0 0.00 Total Area = 776,061 sf = 17.82 acres Composite SCS CN = 60 % Impervious = 6.68% TIME OF CONCENTRATION (REF: SCS Segmental Approach, TR -55). Segment 1: Overland Flow Length = Upstream Elevation = Downstream Elevation = Height = Slope = Manning's n = P (2-year/24-hour) = Segment Time = 2199 Segment 2: Concentrated Flow ft Length = ft Upstream Elevation = ft Downstream Elevation = ft Height = ft/ft Slope = wooded -light underbrush Paved? inches (Troutman, NC) Velocity = minutes Segment Time = Upstream Elevation = ft ft ft ft ft/ft ft/sec minutes 100 121 869.00 856.00 856.00 836.00 13.00 20.00 0.1300 0.1653 0.40 No 3.42 6.56 9.82 0.31 Segment 4: Channel Flow Length = 2199 ft Upstream Elevation = 836.00 ft Downstream Elevation = 817.50 ft Height = 18.50 ft Slope = 0.0084 ft/ft Manning's n = 0.045 major stream Flow Area = 49 sf (assume 7'x7' channel) Wetted Perimeter = 21 If (assume 7'x7' channel) Channel Velocity = 5.34 ft/sec Segment Time = 6.86 minutes Time of Concentration = 16.99 minutes SCS Lag Time =1 10.19 Iminutes 'J MCADAMS Scenario: Post 2 year TSUB2TSCMA SUB 2 T SCM B SUB 2 T SCM C SC C SC B POA A POA C SUB POA B / BROOKSIDE K. GALLT RYN 17010.ppc 11/14/2018 9 MCADAMS Subsection: Master Network Summary Catchments Summary Label Scenario Return Hydrograph Time to Peak Peak Flow Event Volume (min) (ft3/s) (years) (ac -ft) SUB 1 Post 2 year 2 0.085 727.000 0.98 SUB 1 Post 10 year 10 0.215 725.000 2.80 SUB 2 To SCM A Post 2 year 2 1.908 722.000 37.40 SUB 2 To SCM A Post 10 year 10 3.734 721.000 66.79 SUB 2 To SCM B Post 2 year 2 1.954 721.000 39.17 SUB 2 To SCM B Post 10 year 10 3.622 721.000 65.19 SUB 2 To SCM C Post 2 year 2 0.714 722.000 13.30 SUB 2 To SCM C Post 10 year 10 1.508 721.000 26.42 SUB 2 BYPASS Post 2 year 2 0.708 732.000 5.58 SUB 2 BYPASS Post 10 year 10 1.884 730.000 18.84 Node Summary Label Scenario Return Hydrograph Time to Peak Peak Flow Event Volume (min) (ft3/s) (years) (ac -ft) POA 1 Post 2 year 2 0.085 727.000 0.98 POA 1 Post 10 year 10 0.215 725.000 2.80 POA 2 Post 2 year 2 1.275 732.000 5.91 POA 2 Post 10 year 10 4.131 730.000 19.38 POA A Post 2 year 2 0.221 1,440.000 0.24 POA A Post 10 year 10 0.906 1,072.000 1.70 POA B Post 2 year 2 0.226 1,440.000 0.24 POA B Post 10 year 10 0.813 1,072.000 1.54 POA C Post 2 year 2 0.124 1,440.000 0.14 POA C Post 10 year 10 0.544 887.000 1.31 Pond Summary Label Scenario Return Hydrograph Time to Peak Peak Flow Event Volume (min) (ft3/s) (years) (ac -ft) Maximum Maximum Water Pond Storage Surface (ac -ft) Elevation (N/A) (ft) Post 2 year SCM A (IN) Post 2 year 2 1.908 722.000 37.40 (N/A) (N/A) SCM A Post 2 year 2 0.221 1,440.000 0.24 854.56 1.686 (OUT) SCM A (IN) Post 10 year 10 3.734 721.000 66.79 (N/A) (N/A) SCM A Post 10 year 10 0.906 1,072.000 1.70 856.04 2.845 (OUT) SCM B (IN) Post 2 year 2 1.954 721.000 39.17 (N/A) (N/A) SCM B Post 2 year 2 0.226 1,440.000 0.24 843.62 1.726 (OUT) SCM B (IN) Post 10 year 10 3.622 721.000 65.19 (N/A) (N/A) SCM B Post 10 year 10 0.813 1,072.000 1.54 845.04 2.825 (OUT) BROOKSIDE K. GALLT RYN 17010. ppc 2/13/2019 9 MCADAMS Subsection: Master Network Summary Pond Summary Label Scenario Return Hydrograph Time to Peak Peak Flow Maximum Maximum Event Volume (min) (ft3/s) Water Pond Storage (years) (ac -ft) Surface (ac -ft) Elevation (ft) SCM C (IN) Post 2 year 2 0.714 722.000 13.30 (N/A) (N/A) SCM C Post 2 year 2 0.124 1,440.000 0.14 857.07 0.589 (OUT) SCM C (IN) Post 10 year 10 1.508 721.000 26.42 (N/A) (N/A) SCM C Post 10 year 10 0.544 887.000 1.31 858.53 0.972 (OUT) BROOKSIDE K. GALLT RYN 17010. ppc 2/13/2019 \ I I I I I I I I I \ I I I I I r � /- � • l� III \ �'�-I 1 / ) \ � �/ /���� _ — -�� o / I\�\`�� \\\ 11IIIIIIIIIIIIIIIIIIIIII� j1\�\ \\SII \�-� ��i _ r �� rP/�n TPAD �, ��',��-o� 1 I V I I / I I I II�III �\ I � - 75l, 7 Ift(� 1111111 11 \1 I II I FI , � � `� �� = l I` ■" � / / IIII \��\ I I 1 /Sr_11 I 7 SUB 2- To SCM A — — r -I-1— AREA = 17.93 AC111111111) I � T - l �ll�lll/�IiIl _ l, yv 40101/ �J - / �!/ /�SUB 2- To Bypass J AREA = 8.60 AC l 1 )I l�1 I � Y \ 1! n 1 ll I I �I�� 52 �� I I SZ I � � _ �• 01 f 11 SS — ��) "Jill(v J /� ��J f 1 I ,>)✓\l�/ ///� )ILI `T lit ell _� II I( ��J�/�%%////�/ n91P� l��I �r � ��d� // Illi �j /�j \ II III 11/// _j / �� 1 VA I ll�lll/ l 111 Jfll� �/�lll�l/ llll 771 11) J % / l I Illlll I II I�\7�\� ' I �� I IIII III �I/ \Ill Tc PATH I\� t DA ��l / / � � / �/� SU B 2- To SCM B / K s //, /%/ -/r� i15,1(1 > l ,, l I 0/ POA 1 _ / v 11w v v I AREA - 15.23.. C / /iceAV/t//� /TO "o, ffiffifflm SUB 1 \ Z \ IIIc I \� // /,� /�// / //i�j�////�Jl ��/ •��:;�;"a;; •'���� III � \ 1\�� �/ /////l AREA = 1.83 AC 1 / / �///////1 11/ �� :�•• / / rrr / /r- v PROPERTY LINE SUB 2- To SCM C �i ��`1 II \ ) J �� / �/ < / // �% ,? l �l /IIII '�';�:; •1:r•-/i/l�ril l r/�/r, /\ I /�( SITE AREA = 57.80 AC AREA = 8.69 AC10- li©�/� _ l l / / / � � � i / /��/i/ ��! / — % / / // //�� /�'� /�//moi / � _ _ � � ..� l 1/I •• /P/ // / r/ / // �/ r/� / / I /� //i /� /iii � / _--_ � ��/ / � •� /// � / i r Bypass SUB 2- To B ass AREA = 0.99 AC 7a 7 POA 2 _j \ � J I I I SUB 2- To Bypass AREA = 8.23 AC � � I FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION I 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER REVISIONS NO. DATE PLAN INFORMATION PROJECT NO. RYN-17010 w N W JAA LU LK SCALE Q OC z SHEET Q J O LU U �C z O 0 O U O O z CC --J( z W ILL. zoo O U REVISIONS NO. DATE PLAN INFORMATION PROJECT NO. RYN-17010 FILENAME RYN17010-POST CHECKED BY JAA DRAWN BY LK SCALE V=100' DATE 02.13.2019 SHEET POST -DEVELOPMENT DRAINAGE AREA MAP POST DESIGN OF STORMWATER CONTROL MEASURE A BROOKSIDE SUBDIVISION RYN-17010 'J McADAMs STAGE -STORAGE FUNCTION - ABOVE NORMAL POOL Project Name: Brookside Project Number: RYN-17010 Facility ID: SCM A ABOVE NORMAL POOL Date: 2/13/2019 Calculated By: K. Gallt Average Incremental Accumulated Calculated Contour Stage Contour Area Contour Area Contour Vol Contour Vol Stage rftl rftl rsfl rsfl rcfl rcfl rftl 852.00 0.00 24,199 852.50 0.50 26,783 25,491 12,746 12,746 0.51 854.00 2.00 30,653 28,718 43,077 55,823 1.94 856.00 4.00 36,070 33,362 66,723 122,546 3.95 858.00 6.00 41,714 38,892 77,784 200,330 6.17 Storage vs. Stage 250,000 200,000 U 150,000 d rn 0 100,000 50,000 y = 26905x',1033 R1 = 0.9994 0 I i i 0.00 1.00 2.00 Stage (feet) b = 1.1033 Ks = 26905 'J McADAMs STAGE -STORAGE FUNCTION - BELOW NORMAL POOL Project Name: Brookside Project Number: RYN-17010 Facility ID: SCM A MAIN POOL Date: 2/13/2019 Calculated By: K. Gallt Average Incremental Accumulated Calculated Contour Stage Contour Area Contour Area Contour Vol Contour Vol Stage rftl rftl rsfl rsfl rcfl rcfl rftl 846.00 0.00 6,236 848.00 2.00 9,364 7,800 15,600 15,600 2.01 850.00 4.00 12,696 11,030 22,060 37,660 3.92 851.50 5.50 15,556 14,126 21,189 58,849 5.50 852.00 6.00 17,242 16,399 8,200 67,049 6.07 80,000 70,000 60,000 V 50,000 m 40,000 ° 30,000 20,000 10,000 Storage vs. Stage y = 6184.3x'.3214 R2 = 0.9993 0 1 i i i i 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 Stage (feet) b = 1.3214 Ks = 6184 NORTH FOREBAY Average Incremental Accumulated Calculated Contour Stage Contour Area Contour Area Contour Vol Contour Vol Stage fftl fftl fsfl fsfl fcfl fcfl fftl 848.00 0.00 718 850.00 2.00 1,571 1,145 2,289 2,289 2.00 851.50 3.50 2,365 1,968 2,952 5,241 3.47 852.00 4.00 2,890 2,628 1,314 6,555 4.03 7,000 6,000 5,000 4,000 3,000 2,000 1,000 0 4- 0.00 Storage vs. Stage y = 803.55x'.5068 R2 = 0.9996 1.00 2.00 3.00 4.00 Stage (feet) b = 1.5068 KS = 1 804 b.uu SOUTH FOREBAY Average Incremental Accumulated Calculated Contour Stage Contour Area Contour Area Contour Vol Contour Vol Stage fftl fftl fsfl fsfl fcfl fcfl fftl 848.00 0.00 650 850.00 2.00 1,685 1,168 2,335 2,335 2.00 851.50 3.50 2,656 2,171 3,256 5,591 3.47 852.00 4.00 3,400 3,028 1,514 7,105 4.03 8,000 7,000 6,000 5,000 4,000 3,000 2,000 1,000 0 Storage vs. Stage y = 772.27x'.5921 R2 = 0.9994 0.00 1.00 2.00 3.00 4.00 5.00 Stage (feet) b = 1.5921 KS = 1 772 'J McADAMs VOLUME CALCULATIONS Project Name: Brookside Project Number: RYN-17010 Facility ID: SCM A TOTAL VOLUME Volume of Main Pool = 67,049 cf Volume of Forebays = 13,660 cf Total Volume Below NWSE = 80,708 cf = 1.85 acre -ft Total Volume Above NWSE = 200,330 cf = 4.60 acre -ft Total Volume of Facility = 281,038 cf = 6.45 acre -ft FOREBAY CALCULATION Volum of Main Pool = 67,049 cf Volume of Forebays = 13,660 cf % Forebay = 20% AVERAGE DEPTH OF POND Total Volume Below NWSE = 80,708 cf Surface Area at NWSE = 24,199 sf Date: 2/13/2019 Calculated By: K. Gallt Foreba volume should be approximately 20% Average Depth = JAverage depth must be greater than 3.0 'J MCADAMs SURFACE AREA CALCULATION Project Name: Brookside Project Number: RYN-17010 Facility ID: SCM A DRAINAGE CHARACTERISTICS Total Drainage Area =acres Total Impervious Area = 6.97 acres % Impervious = 38.9% DETERMINATION OF REQUIRED SURFACE AREA (REF: NCDWQ BMP Handbook, 2007). Average Depth =F ft TSS Removal = 85% SAIDA table for Piedmont/Mountain region Date: 2/13/2019 Calculated By: K. Gallt Include both onsite and offsite impervious area Average Depth 3 3.34 4 Lower Boundary 30.0% 1.17 0.94 % Impervious 38.9% 1.47 1.46 1.21 Upper Boundary 40.0% 1.51 1.24 SA/DA required = 1.46 Surface Area Required = 11,396 ft = 0.26 acres Surface Area Provided = 24,199 ft TIMcADAMS WATER QUALITY VOLUME CALCULATION Project Name: Brookside Project Number: RYN-17010 Facility ID: SCM A DETERMINATION OF WATER QUALITY VOLUME (REF: Simple Method, Schueler, 1987). WQV =PxRvxA/12 where, WQV = Water Quality Volume (acre -ft) Rv = 0.05 + 0.009 x I, where I is % Impervious Cover A = Area (acres) P = Rainfall (inches) Total Drainage Area, A = 17.932 acres Total Impervious Area = 6.97 acres % Impervious, 1 = 38.9% Rainfall, P = 1.00 inches R„ =1 0.400 acres WQV=J 0.598 acre -ft 26,038 cf ASSOCIATED DEPTH IN POND WQV=J 26,038 cf Ks =1 26905 b=1 1.1033 NWSE =1 852.00 ft Date: 2/13/2019 Calculated By: K. Gallt Depth of WQV in Pond = 0.97 ft = 11.65 inches Elevation = 852.97 ft Spillway must be set above this elevation 'J MCADAMS WATER QUALITY VOLUME DRAWDOWN CALCULATION Project Name: Brookside Project Number: RYN-17010 Facility ID: SCM A DRAWDOWN DESIGN Using falling head Orifice Diameter = 2.25 inches Number of Orifices = 1 Orifice Coefficient, Cd = 0.60 0.118 Ks = 26905 20,664 b = 1.1033 0.112 NWSE = 852.00 ft WQV = 26,038 0.105 WQV Elevation in Pond = 852.97 ft Date: 2/13/2019 Calculated By: K. Gallt Average Incremental Incremental WSEL Storage Siphon Flow Flow Volume Time [ft] [cf] [cfs] [cfs] [cf] [sec] 852.97 26038 0.124 852.89 23534 0.118 0.121 2,505 20,664 852.80 21054 0.112 0.115 2,480 21,590 852.72 18601 0.105 0.108 2,453 22,682 852.63 16178 0.097 0.101 2,423 23,996 852.55 13788 0.089 0.093 2,389 25,624 852.46 11437 0.080 0.085 2,351 27,720 852.38 9131 0.070 0.075 2,306 30,576 852.29 6879 0.059 0.065 2,253 34,831 852.21 4694 0.044 0.052 2,184 42,316 852.12 2604 0.021 0.033 2,090 63,968 Drawdown Time = 3.63 days DRAWDOWN DESIGN Using average head Average Head on Orifice =0.292 inches Orifice Coefficient, Cd = 0.60 Area of Orifice = 0.028 sf Flowrate, Q =F---O.-07-2--]cfs 2-5 day drawdown required Drawdown Time = 4.19 days 2-5 day drawdown required 'J MCADAMS Subsection: Elevation -Area Volume Curve Label: SCM A Elevation Planimeter Area Al+A2+sqr (ft) (ft2) (acres) (Al*A2) (acres) Return Event: 2 years Storm Event: 2 year Volume Volume (Total) (ac -ft) (ac -ft) 852.00 0.0 0.556 0.000 0.000 0.000 852.50 0.0 0.615 1.755 0.292 0.292 854.00 0.0 0.704 1.976 0.988 1.281 856.00 0.0 0.828 2.295 1.530 2.811 858.00 0.0 0.958 2.676 1.784 4.595 BROOKSIDE RYN17010.ppc K. GALLT 2/13/2019 'J MCADAMS Subsection: Outlet Input Data Label: Composite Outlet Structure - SCM A Requested Pond Water Surface Elevations Minimum (Headwater) 852.00 ft Increment (Headwater) 0.50 ft Maximum (Headwater) 858.00 ft Outlet Connectivity Structure Type Outlet ID Direction Outfall El E2 (ft) (ft) Orifice -Circular Orifice A Forward Culvert 853.00 858.00 Inlet Box Riser Forward Culvert 856.00 858.00 Orifice -Circular WQ Orifice Forward Culvert 852.00 858.00 Culvert -Circular Culvert Forward TW 846.00 858.00 Tailwater Settings Tailwater (N/A) (N/A) BROOKSIDE RYN17010.ppc Return Event: 2 years Storm Event: 2 year K. GALLT 2/13/2019 'J MCADAMS Subsection: Outlet Input Data Label: Composite Outlet Structure - SCM A Structure ID: Riser Structure Type: Inlet Box Number of Openings 1 Elevation 856.00 ft Orifice Area 16.0 ft2 Orifice Coefficient 0.600 Weir Length 16.00 ft Weir Coefficient 3.00 (ft^0.5)/s K Reverse 1.000 Manning's n 0.000 Kev, Charged Riser 0.000 Weir Submergence False Orifice H to crest False BROOKSIDE RYN17010.ppc Return Event: 2 years Storm Event: 2 year K. GALLT 2/13/2019 'J MCADAMS Subsection: Outlet Input Data Label: Composite Outlet Structure - SCM A Structure ID: Culvert Structure Type: Culvert -Circular Number of Barrels 1 Diameter 24.0 in Length 97.00 ft Length (Computed Barrel) 97.01 ft Slope (Computed) 0.010 ft/ft Outlet Control Data Manning's n 0.013 Ke 0.500 Kb 0.012 Kr 0.000 Convergence Tolerance 0.00 ft Inlet Control Data Equation Form Form 1 K 0.0098 M 2.0000 C 0.0398 Y 0.6700 Tl ratio (HW/D) 0.000 T2 ratio (HW/D) 1.302 Slope Correction Factor -0.500 Use unsubmerged inlet control 0 equation below T1 elevation. Use submerged inlet control 0 equation above T2 elevation In transition zone between unsubmerged and submerged inlet control, interpolate between flows at T1 & T2... Tl Elevation 846.00 ft Tl Flow 15.55 ft3/s T2 Elevation 848.60 ft T2 Flow 17.77 ft3/s Return Event: 2 years Storm Event: 2 year BROOKSIDE K. GALLT RYN 17010. ppc 2/13/2019 'J MCADAMS Subsection: Outlet Input Data Return Event: 2 years Label: Composite Outlet Structure - SCM A Storm Event: 2 year Structure ID: WQ Orifice Structure Type: Orifice -Circular Number of Openings 1 Elevation 852.00 ft Orifice Diameter 2.3 in Orifice Coefficient 0.600 Structure ID: Orifice A Structure Type: Orifice -Circular Number of Openings 1 Elevation 853.00 ft Orifice Diameter 1.0 in Orifice Coefficient 0.600 Structure ID: TW Structure Type: TW Setup, DS Channel Tailwater Type Free Outfall Convergence Tolerances Maximum Iterations 30 Tailwater Tolerance 0.01 ft (Minimum) Tailwater Tolerance 0.50 ft (Maximum) Headwater Tolerance 0.01 ft (Minimum) Headwater Tolerance 0.50 ft (Maximum) Flow Tolerance (Minimum) 0.001 ft3/s Flow Tolerance (Maximum) 10.000 ft3/s BROOKSIDE K. GALLT RYN 17010. ppc 2/13/2019 'J MCADAMS Subsection: Composite Rating Curve Label: Composite Outlet Structure - SCM A Composite Outflow Summary Return Event: 2 years Storm Event: 2 year Water Surface Flow Tailwater Elevation Convergence Error Contributing Structures Elevation (ft3/s) (ft) (ft) (ft) 852.00 0.00 (N/A) 0.00 (no Q: Orifice A,Riser,WQ Orifice,Culvert) 852.50 0.08 (N/A) 0.00 WQ Orifice,Culvert (no Q: Orifice A,Riser) 853.00 0.13 (N/A) 0.00 WQ Orifice,Culvert (no Q: Orifice A,Riser) 853.50 0.17 (N/A) 0.00 Orifice A,WQ Orifice,Culvert (no Q: Riser) 854.00 0.21 (N/A) 0.00 Orifice A,WQ Orifice,Culvert (no Q: Riser) 854.50 0.24 (N/A) 0.00 Orifice A,WQ Orifice,Culvert (no Q: Riser) 855.00 0.26 (N/A) 0.00 Orifice A,WQ Orifice,Culvert (no Q: Riser) 855.50 0.28 (N/A) 0.00 Orifice A,WQ Orifice,Culvert (no Q: Riser) 856.00 0.31 (N/A) 0.00 Orifice A,WQ Orifice,Culvert (no Q: Riser) 856.50 17.29 (N/A) 0.00 Orifice A,Riser,WQ Orifice,Culvert 857.00 48.07 (N/A) 0.00 Orifice A,Riser,WQ Orifice,Culvert 857.50 49.68 (N/A) 0.00 Riser,Culvert (no Q: Orifice A,WQ Orifice) 858.00 50.85 (N/A) 0.00 Riser,Culvert (no Q: Orifice A,WQ Orifice) BROOKSIDE K. GALLT RYN 17010. ppc 2/13/2019 'J MCADAMS Subsection: Level Pool Pond Routing Summary Label: SCM A (IN) Infiltration 854.56 ft Infiltration Method No Infiltration (Computed) 1.686 ac -ft Initial Conditions Elevation (Water Surface, 852.00 ft Initial) 1.908 ac -ft Volume (Initial) 0.000 ac -ft Flow (Initial Outlet) 0.00 ft3/s Flow (Initial Infiltration) 0.00 ft3/s Flow (Initial, Total) 0.00 ft3/s Time Increment 1.000 min Inflow/Outflow Hydrograph Summary Flow (Peak In) 37.40 ft3/s Time to Peak (Flow, In) 722.000 min Flow (Peak Outlet) 0.24 ft3/s Time to Peak (Flow, Outlet) 1,440.000 min Elevation (Water Surface, 854.56 ft Peak) Volume (Peak) 1.686 ac -ft Mass Balance (ac -ft) Volume (Initial) 0.000 ac -ft Volume (Total Inflow) 1.908 ac -ft Volume (Total Infiltration) 0.000 ac -ft Volume (Total Outlet 0.221 ac -ft Outflow) Volume (Retained) 1.686 ac -ft Volume (Unrouted) -0.001 ac -ft Error (Mass Balance) 0.1 % Return Event: 2 years Storm Event: 2 year BROOKSIDE K. GALLT RYN 17010. ppc 2/13/2019 'J MCADAMS Subsection: Level Pool Pond Routing Summary Label: SCM A (IN) Infiltration 856.04 ft Infiltration Method No Infiltration (Computed) 2.845 ac -ft Initial Conditions Elevation (Water Surface, 852.00 ft Initial) 3.734 ac -ft Volume (Initial) 0.000 ac -ft Flow (Initial Outlet) 0.00 ft3/s Flow (Initial Infiltration) 0.00 ft3/s Flow (Initial, Total) 0.00 ft3/s Time Increment 1.000 min Inflow/Outflow Hydrograph Summary Flow (Peak In) 66.79 ft3/s Time to Peak (Flow, In) 721.000 min Flow (Peak Outlet) 1.70 ft3/s Time to Peak (Flow, Outlet) 1,072.000 min Elevation (Water Surface, 856.04 ft Peak) Volume (Peak) 2.845 ac -ft Mass Balance (ac -ft) Volume (Initial) 0.000 ac -ft Volume (Total Inflow) 3.734 ac -ft Volume (Total Infiltration) 0.000 ac -ft Volume (Total Outlet 0.906 ac -ft Outflow) Volume (Retained) 2.826 ac -ft Volume (Unrouted) -0.002 ac -ft Error (Mass Balance) 0.0% Return Event: 10 years Storm Event: 10 year BROOKSIDE K. GALLT RYN 17010. ppc 2/13/2019 'J MCADAMS Subsection: Level Pool Pond Routing Summary Label: SCM A (IN) Infiltration 856.67 ft Infiltration Method No Infiltration (Computed) 3.383 ac -ft Initial Conditions Elevation (Water Surface, 852.00 ft Initial) 6.941 ac -ft Volume (Initial) 0.000 ac -ft Flow (Initial Outlet) 0.00 ft3/s Flow (Initial Infiltration) 0.00 ft3/s Flow (Initial, Total) 0.00 ft3/s Time Increment 1.000 min Inflow/Outflow Hydrograph Summary Flow (Peak In) 104.58 ft3/s Time to Peak (Flow, In) 721.000 min Flow (Peak Outlet) 27.99 ft3/s Time to Peak (Flow, Outlet) 752.000 min Elevation (Water Surface, 856.67 ft Peak) Volume (Peak) 3.383 ac -ft Mass Balance (ac -ft) Volume (Initial) 0.000 ac -ft Volume (Total Inflow) 6.941 ac -ft Volume (Total Infiltration) 0.000 ac -ft Volume (Total Outlet 4.097 ac -ft Outflow) Volume (Retained) 2.841 ac -ft Volume (Unrouted) -0.003 ac -ft Error (Mass Balance) 0.0% Return Event: 100 years Storm Event: 100 year BROOKSIDE K. GALLT RYN 17010. ppc 2/13/2019 'J MCADAMs RIPRAP OUTLET PROTECTION Project Name: Brookside Project Number: RYN-17010 Facility ID: SCM A DESIGN OF RIPRAP OUTLET PROTECTION Calculations based on NY DOT method - Pages 8.06.05 through 8.06.06 in NC Erosion Control Manual. Flow, Q,o_n=V2.O Outlet pipe diameter = cfs Slope =% Outlet flowrate = Pipe Diameter, Do=in Thickness = =feet 4.29 ft/sec Number of pipes =Pipe Material = Class A separation =feet 3x Do Zone Manning's n = 1 Date: 11/27/2018 Calculated By: K. Gallt Pipe diameter (ft) Zone from graph above =FM 1 8.00 ft Outlet pipe diameter = 24 in Outlet flowrate = 1.70cfs Thickness = Outlet velocity = 4.29 ft/sec Length Material = Class A 4xDa 3x Do Zone Material Diameter 1 Class A 3 2 Class B 6 3 Class 1 13 4 Class 1 13 5 Class 11 23 6 Class 11 23 7 Study Required Length = 8.00 ft Width = 6.00 ft Stone diameter = 3.00 in Thickness = 9.00 in Thickness Length Width 9 4xDa 3x Do 22 6xDa 3x Do 22 8x Da 3x Do 22 8x Da 3x Do 27 10xDa 3x Do 27 10xDa 3x Do DESIGN OF STORMWATER CONTROL MEASURE B BROOKSIDE SUBDIVISION RYN-17010 'J McADAMs STAGE -STORAGE FUNCTION - ABOVE NORMAL POOL Project Name: Brookside Project Number: RYN-17010 Facility ID: SCM B ABOVE NORMAL POOL Date: 2/13/2019 Calculated By: K. Gallt Average Incremental Accumulated Calculated Contour Stage Contour Area Contour Area Contour Vol Contour Vol Stage rftl rftl rsfl rsfl rcfl rcfl rftl 841.00 0.00 24,506 841.50 0.50 26,856 25,681 12,841 12,841 0.51 842.00 1.00 28,052 27,454 13,727 26,568 0.99 844.00 3.00 32,979 30,516 61,031 87,599 2.92 846.00 5.00 38,132 35,556 71,111 158,710 5.01 847.00 6.00 40,794 39,463 39,463 198,173 6.13 Storage vs. Stage 250,000 200,000 y = 26983x' 0994 LL R2 = 0.9996 v 150,000 d m 0 100,000 N 50,000 0 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 Stage (feet) b = 1.0994 KS = 26983 STAGE -STORAGE FUNCTION - BELOW NORMAL POOL Project Name: Brookside Date: 2/13/2019 Project Number: RYN-17010 Calculated By: K. Gallt Facility ID: SCM B MAIN POOL FOREBAY Average Incremental Accumulated Calculated Contour Stage Contour Area Contour Area Contour Vol Contour Vol Stage rffl rffl W1 W1 rrf1 rrf1 rffl 836.00 0.00 10,230 y = 10211x 1 2111 60,000 R' = 0.9998 838.00 2.00 13,288 11,759 23,518 23,518 2.00 840.00 4.00 16,605 14,947 29,893 53,411 3.97 840.50 4.50 17,473 17,039 8,520 61,931 4.49 841.00 5.00 19,152 18,313 9,156 71,087 5.04 80,000 70,000 Storage vs. Stage 1,187 y = 10211x 1 2111 60,000 R' = 0.9998 V 50,000 2.00 2,364 rn 40,000 m 3,551 3,551 y 30,000 20,000 10,000 0 0.00 840.00 4.00 1.00 2.00 3.00 4.00 5.00 6.00 Stage (feet) b = 1 1.2001 Ks = 1 10211 Average Incremental Accumulated Calculated Contour Stage Contour Area Contour Area Contour Vol Contour Vol Stage rffl rffl rcfl rcfl rrfl rrfl rffl 836.00 0.00 1,187 838.00 2.00 2,364 1,776 3,551 3,551 2.01 840.00 4.00 3,831 3,098 6,195 9,746 3.95 840.50 4.50 4,241 4,036 2,018 11,764 4.49 841.00 5.00 5,012 4,627 2,313 14,077 5.06 Storage vs. Stage 16,000 14,000 Y = 1258.8x1.4111 12,000 R1 = 0.9994 tLLi 10,000 rn 8,000 E ° 6,000 N 4,000 2,000 0 0.00 1.00 2.00 3.00 4.00 5.00 6.00 Stage (feet) b = 1 1.4891 KS = 1 1259 'J MCADAMS VOLUME CALCULATIONS Project Name: Brookside Project Number: RYN-17010 Facility ID: SCM B TOTAL VOLUME Volume of Main Pool =W196 cf Volume of Forebays =cf Total Volume Below NWSE =cf =acre -ft Total Volume Above NWSE = 198,173 cf = 4.55 acre -ft Total Volume of Facility = 283,337 cf = 6.50 acre -ft FOREBAY CALCULATION Volum of Main Pool = 71,087 cf Volume of Forebays = 14,077 cf % Forebay = 20% AVERAGE DEPTH OF POND Total Volume Below NWSE = 85,164 cf Surface Area at NWSE = 24,506 sf Date: 2/13/2019 Calculated By: K. Gallt Foreba volume should be approximately 20% Average Depth = JAverage depth must be greater than 3.0 'J MCADAMs SURFACE AREA CALCULATION Project Name: Brookside Project Number: RYN-17010 Facility ID: SCM B DRAINAGE CHARACTERISTICS Total Drainage Area = 1 5.23 acres Total Impervious Area =1 7.31 Jacres % Impervious = 48.0% DETERMINATION OF REQUIRED SURFACE AREA (REF: NCDWQ BMP Handbook, 2007). Average Depth =F ft TSS Removal = 85% SAIDA table for Piedmont/Mountain region Date: 2/13/2019 Calculated By: K. Gallt Include both onsite and offsite impervious area Average Depth 3 3.48 4 Lower Boundary 40.0% 1.51 1.24 % Impervious 48.0% 1.73 1.53 1.46 Upper Boundary 50.0% 1.79 1.51 SA/DA required = 1.53 Surface Area Required = 10,121 ft = 0.23 acres Surface Area Provided = 24,506 ft TIMcADAMS WATER QUALITY VOLUME CALCULATION Project Name: Brookside Project Number: RYN-17010 Facility ID: SCM B DETERMINATION OF WATER QUALITY VOLUME (REF: Simple Method, Schueler, 1987). WQV =PxRvxA/12 where, WQV = Water Quality Volume (acre -ft) Rv = 0.05 + 0.009 x I, where I is % Impervious Cover A = Area (acres) P = Rainfall (inches) Total Drainage Area, A = 15.227 acres Total Impervious Area = 7.31 acres % Impervious, 1 = 48.0% Rainfall, P = 1.00 inches R„ =1 0.482 acres WQV=J 0.612 acre -ft 26,660 cf ASSOCIATED DEPTH IN POND WQV=J 26,660 cf Ks =1 26983 b=1 1.0994 NWSE =1 841.00 ft Date: 2/13/2019 Calculated By: K. Gallt Depth of WQV in Pond = 0.99 ft = 11.87 inches Elevation = 841.99 ft Spillway must be set above this elevation 'J MCADAMS WATER QUALITY VOLUME DRAWDOWN CALCULATION Project Name: Brookside Project Number: RYN-17010 Facility ID: SCM B DRAWDOWN DESIGN Using falling head Orifice Diameter = 2.25 inches Number of Orifices = 1 Orifice Coefficient, Cd = 0.60 0.119 Ks = 26983 20,890 b = 1.0994 0.113 NWSE = 841.00 ft WQV = 26,660 0.106 WQV Elevation in Pond = 841.99 ft Date: 2/13/2019 Calculated By: K. Gallt Average Incremental Incremental WSEL Storage Siphon Flow Flow Volume Time [ft] [cf] [cfs] [cfs] [cf] [sec] 841.99 1 26660 0.126 841.90 24101 0.119 0.122 2,559 20,890 841.82 21567 0.113 0.116 2,534 21,833 841.73 19060 0.106 0.109 2,508 22,945 841.64 16582 0.098 0.102 2,478 24,283 841.56 14137 0.090 0.094 2,445 25,940 841.47 11730 0.081 0.086 2,407 28,074 841.38 9367 0.071 0.076 2,363 30,979 841.30 7057 0.060 0.065 2,310 35,302 841.21 4815 0.045 0.052 2,242 42,890 841.12 2666 0.021 0.033 2,149 64,798 Drawdown Time = 3.68 days DRAWDOWN DESIGN Using average head Average Head on Orifice = 0.298 inches Orifice Coefficient, Cd = 0.60 Area of Orifice = 0.028 sf Flowrate, Q = 0.073 cfs 2-5 day drawdown required Drawdown Time = 4.25 days 2-5 day drawdown required 'J MCADAMS Subsection: Elevation -Area Volume Curve Label: SCM B Elevation Planimeter Area Al+A2+sqr (ft) (ft2) (acres) (Al*A2) (acres) Return Event: 2 years Storm Event: 2 year Volume Volume (Total) (ac -ft) (ac -ft) 841.00 0.0 0.563 0.000 0.000 0.000 841.50 0.0 0.617 1.768 0.295 0.295 842.00 0.0 0.644 1.891 0.315 0.610 844.00 0.0 0.757 2.099 1.400 2.009 846.00 0.0 0.875 2.447 1.631 3.640 847.00 0.0 0.937 2.717 0.906 4.546 BROOKSIDE RYN17010.ppc K. GALLT 2/13/2019 'J MCADAMS Subsection: Outlet Input Data Label: Composite Outlet Structure - SCM B Requested Pond Water Surface Elevations Minimum (Headwater) 841.00 ft Increment (Headwater) 0.50 ft Maximum (Headwater) 847.00 ft Outlet Connectivity Structure Type Outlet ID Direction Outfall El E2 (ft) (ft) Orifice -Circular Orifice B Forward Culvert 842.00 847.00 Inlet Box Riser Forward Culvert 845.00 847.00 Orifice -Circular WQ Orifice Forward Culvert 841.00 847.00 Culvert -Circular Culvert Forward TW 836.00 847.00 Tailwater Settings Tailwater (N/A) (N/A) BROOKSIDE RYN17010.ppc Return Event: 2 years Storm Event: 2 year K. GALLT 2/13/2019 'J MCADAMS Subsection: Outlet Input Data Label: Composite Outlet Structure - SCM B Structure ID: Riser Structure Type: Inlet Box Number of Openings 1 Elevation 845.00 ft Orifice Area 16.0 ft2 Orifice Coefficient 0.600 Weir Length 16.00 ft Weir Coefficient 3.00 (ft^0.5)/s K Reverse 1.000 Manning's n 0.000 Kev, Charged Riser 0.000 Weir Submergence False Orifice H to crest False BROOKSIDE RYN17010.ppc Return Event: 2 years Storm Event: 2 year K. GALLT 2/13/2019 'J MCADAMS Subsection: Outlet Input Data Label: Composite Outlet Structure - SCM B Structure ID: Culvert Structure Type: Culvert -Circular Number of Barrels 1 Diameter 24.0 in Length 74.00 ft Length (Computed Barrel) 74.03 ft Slope (Computed) 0.027 ft/ft Outlet Control Data Manning's n 0.013 Ke 0.500 Kb 0.012 Kr 0.000 Convergence Tolerance 0.00 ft Inlet Control Data Equation Form Form 1 K 0.0098 M 2.0000 C 0.0398 Y 0.6700 Tl ratio (HW/D) 1.147 T2 ratio (HW/D) 1.293 Slope Correction Factor -0.500 Use unsubmerged inlet control 0 equation below T1 elevation. Use submerged inlet control 0 equation above T2 elevation In transition zone between unsubmerged and submerged inlet control, interpolate between flows at T1 & T2... Tl Elevation 838.29 ft Tl Flow 15.55 ft3/s T2 Elevation 838.59 ft T2 Flow 17.77 ft3/s Return Event: 2 years Storm Event: 2 year BROOKSIDE K. GALLT RYN 17010. ppc 2/13/2019 'J MCADAMS Subsection: Outlet Input Data Return Event: 2 years Label: Composite Outlet Structure - SCM B Storm Event: 2 year Structure ID: WQ Orifice Structure Type: Orifice -Circular Number of Openings 1 Elevation 841.00 ft Orifice Diameter 2.3 in Orifice Coefficient 0.600 Structure ID: Orifice B Structure Type: Orifice -Circular Number of Openings 1 Elevation 842.00 ft Orifice Diameter 1.0 in Orifice Coefficient 0.600 Structure ID: TW Structure Type: TW Setup, DS Channel Tailwater Type Free Outfall Convergence Tolerances Maximum Iterations 30 Tailwater Tolerance 0.01 ft (Minimum) Tailwater Tolerance 0.50 ft (Maximum) Headwater Tolerance 0.01 ft (Minimum) Headwater Tolerance 0.50 ft (Maximum) Flow Tolerance (Minimum) 0.001 ft3/s Flow Tolerance (Maximum) 10.000 ft3/s BROOKSIDE K. GALLT RYN 17010. ppc 2/13/2019 'J MCADAMS Subsection: Composite Rating Curve Label: Composite Outlet Structure - SCM B Composite Outflow Summary Return Event: 2 years Storm Event: 2 year Water Surface Flow Tailwater Elevation Convergence Error Contributing Structures Elevation (ft3/s) (ft) (ft) (ft) 841.00 0.00 (N/A) 0.00 (no Q: Orifice B,Riser,WQ Orifice,Culvert) 841.50 0.08 (N/A) 0.00 WQ Orifice,Culvert (no Q: Orifice B,Riser) 842.00 0.13 (N/A) 0.00 WQ Orifice,Culvert (no Q: Orifice B,Riser) 842.50 0.18 (N/A) 0.00 Orifice B,WQ Orifice,Culvert (no Q: Riser) 843.00 0.21 (N/A) 0.00 Orifice B,WQ Orifice,Culvert (no Q: Riser) 843.50 0.24 (N/A) 0.00 Orifice B,WQ Orifice,Culvert (no Q: Riser) 844.00 0.26 (N/A) 0.00 Orifice B,WQ Orifice,Culvert (no Q: Riser) 844.50 0.29 (N/A) 0.00 Orifice B,WQ Orifice,Culvert (no Q: Riser) 845.00 0.31 (N/A) 0.00 Orifice B,WQ Orifice,Culvert (no Q: Riser) 845.50 17.31 (N/A) 0.00 Orifice B,Riser,WQ Orifice,Culvert 846.00 46.41 (N/A) 0.00 Riser,Culvert (no Q: Orifice B,WQ Orifice) 846.50 47.73 (N/A) 0.00 Riser,Culvert (no Q: Orifice B,WQ Orifice) 847.00 49.01 (N/A) 0.00 Riser,Culvert (no Q: Orifice B,WQ Orifice) BROOKSIDE K. GALLT RYN 17010. ppc 2/13/2019 'J MCADAMS Subsection: Level Pool Pond Routing Summary Label: SCM B (IN) Infiltration 843.62 ft Infiltration Method No Infiltration (Computed) 1.726 ac -ft Initial Conditions Elevation (Water Surface, 841.00 ft Initial) 1.954 ac -ft Volume (Initial) 0.000 ac -ft Flow (Initial Outlet) 0.00 ft3/s Flow (Initial Infiltration) 0.00 ft3/s Flow (Initial, Total) 0.00 ft3/s Time Increment 1.000 min Inflow/Outflow Hydrograph Summary Flow (Peak In) 39.17 ft3/s Time to Peak (Flow, In) 721.000 min Flow (Peak Outlet) 0.24 ft3/s Time to Peak (Flow, Outlet) 1,440.000 min Elevation (Water Surface, 843.62 ft Peak) Volume (Peak) 1.726 ac -ft Mass Balance (ac -ft) Volume (Initial) 0.000 ac -ft Volume (Total Inflow) 1.954 ac -ft Volume (Total Infiltration) 0.000 ac -ft Volume (Total Outlet 0.226 ac -ft Outflow) Volume (Retained) 1.726 ac -ft Volume (Unrouted) -0.002 ac -ft Error (Mass Balance) 0.1 % Return Event: 2 years Storm Event: 2 year BROOKSIDE K. GALLT RYN 17010. ppc 2/13/2019 'J MCADAMS Subsection: Level Pool Pond Routing Summary Label: SCM B (IN) Infiltration 845.04 ft Infiltration Method No Infiltration (Computed) 2.825 ac -ft Initial Conditions Elevation (Water Surface, 841.00 ft Initial) 3.622 ac -ft Volume (Initial) 0.000 ac -ft Flow (Initial Outlet) 0.00 ft3/s Flow (Initial Infiltration) 0.00 ft3/s Flow (Initial, Total) 0.00 ft3/s Time Increment 1.000 min Inflow/Outflow Hydrograph Summary Flow (Peak In) 65.19 ft3/s Time to Peak (Flow, In) 721.000 min Flow (Peak Outlet) 1.54 ft3/s Time to Peak (Flow, Outlet) 1,072.000 min Elevation (Water Surface, 845.04 ft Peak) Volume (Peak) 2.825 ac -ft Mass Balance (ac -ft) Volume (Initial) 0.000 ac -ft Volume (Total Inflow) 3.622 ac -ft Volume (Total Infiltration) 0.000 ac -ft Volume (Total Outlet 0.813 ac -ft Outflow) Volume (Retained) 2.808 ac -ft Volume (Unrouted) -0.001 ac -ft Error (Mass Balance) 0.0 % Return Event: 10 years Storm Event: 10 year BROOKSIDE K. GALLT RYN 17010. ppc 2/13/2019 'J MCADAMS Subsection: Level Pool Pond Routing Summary Label: SCM B (IN) Infiltration 845.63 ft Infiltration Method No Infiltration (Computed) 3.317 ac -ft Initial Conditions Elevation (Water Surface, 841.00 ft Initial) 6.468 ac -ft Volume (Initial) 0.000 ac -ft Flow (Initial Outlet) 0.00 ft3/s Flow (Initial Infiltration) 0.00 ft3/s Flow (Initial, Total) 0.00 ft3/s Time Increment 1.000 min Inflow/Outflow Hydrograph Summary Flow (Peak In) 96.85 ft3/s Time to Peak (Flow, In) 721.000 min Flow (Peak Outlet) 24.60 ft3/s Time to Peak (Flow, Outlet) 752.000 min Elevation (Water Surface, 845.63 ft Peak) Volume (Peak) 3.317 ac -ft Mass Balance (ac -ft) Volume (Initial) 0.000 ac -ft Volume (Total Inflow) 6.468 ac -ft Volume (Total Infiltration) 0.000 ac -ft Volume (Total Outlet 3.645 ac -ft Outflow) Volume (Retained) 2.821 ac -ft Volume (Unrouted) -0.002 ac -ft Error (Mass Balance) 0.0 % Return Event: 100 years Storm Event: 100 year BROOKSIDE K. GALLT RYN 17010. ppc 2/13/2019 0 MCADAMs RIPRAP OUTLET PROTECTION Project Name: Brookside Date: 11/27/2018 Project Number: RYN-17010 Calculated By: K. Gallt Facility ID: SCM B DESIGN OF RIPRAP OUTLET PROTECTION Calculations based on NY DOT method - Pages 8.06.05 through 8.06.06 in NC Erosion Control Manual. Flow, Q10_n= 1.54 cfs Slope = 2.70 % Pipe Diameter, Do= 24 in 2.00 feet Number of pipes = 1 Pipe separation = 0.00 feet Manning's n = 0.013 Figure 8.06.6.1 Zone from graph above =FM 2 12.00 ft Outlet pipe diameter =24 Width = in Outlet flowrate = 1.54 cfs Thickness = Outlet velocity = 5.84 ft/sec Length Material = Class B 4x Do 3x Do Zone Material Diameter 1 Class A 3 2 Class B 6 3 Class 1 13 4 Class 1 13 5 Class 11 23 6 Class 11 23 7 Study Required Length = 12.00 ft Width = 6.00 ft Stone diameter = 6.00 in Thickness = 22.00 in Thickness Length Width 9 4x Do 3x Do 22 6x Do 3x Do 22 8x Do 3x Do 22 8x Do 3x Do 27 10xDo 3x Do 27 10xDo 3x Do DESIGN OF STORMWATER CONTROL MEASURE C BROOKSIDE SUBDIVISION RYN-17010 'J McADAMS STAGE -STORAGE FUNCTION - ABOVE NORMAL POOL Project Name: Brookside Project Number: RYN-17010 Facility ID: SCM C ABOVE NORMAL POOL Date: 2/13/2019 Calculated By: K. Gallt Average Incremental Accumulated Calculated Contour Stage Contour Area Contour Area Contour Vol Contour Vol Stage rftl rftl rsfl rsfl rcfl rcfl rftl 854.00 0.00 4,790 854.25 0.25 6,892 5,841 1,460 1,460 0.26 855.25 1.25 8,078 7,485 7,485 8,945 1.21 856.00 2.00 9,005 8,542 6,406 15,351 1.92 857.00 3.00 10,291 9,648 9,648 24,999 2.91 858.00 4.00 11,634 1 10,963 1 10,963 1 35,962 1 3.97 859.00 5.00 13,032 1 12,333 1 12,333 1 48,295 1 5.10 860.00 6.00 14,488 1 13,760 1 13,760 1 62,055 1 6.32 Storage vs. Stage 70,000 60,000 • y = 7131.5x1.1735 50,000 R1 = 0.9989 LL v 40,000 rn 0 30,000 U) 20,000 10,000 0 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 Stage (feet) b = 1.1735 KS = 1 7132 TIMCADAMS STAGE -STORAGE FUNCTION - BELOW NORMAL POOL Project Name: Brookside Project Number: RYN-17010 Facility ID: SCM C ABOVENORMALPOOL Normal Water Surface Elevation = 854.00 Temporary Ponding Elevation = 855.25 Wetland Surface Area = 8,078 Date: 2/13/2019 Calculated By: K. Gallt Elevation Measured Area % of Wetland Zone rftl rsfl Surface Area Deep Pool - Forebay 853.50 to 851.00 909 11% Deep Pool - Non Forebay 853.50 to 851.00 1,092 14% Shallow Water 854.00 to 853.50 2,789 35% Temporary Inundation 855.25 to 854.00 3,288 41% TIMcADAMS WATER QUALITY VOLUME CALCULATION Project Name: Brookside Project Number: RYN-17010 Facility ID: SCM C DETERMINATION OF WATER QUALITY VOLUME (REF: Simple Method, Schueler, 1987). WQV =PxRvxA/12 where, WQV = Water Quality Volume (acre -ft) Rv = 0.05 + 0.009 x I, where I is % Impervious Cover A = Area (acres) P = Rainfall (inches) Total Drainage Area, A =WVOYI. acres Total Impervious Area =acres % Impervious, 1 = Rainfall, P =inches R„ =1 0.303 acres WQV=J 0.219 acre -ft 9,553 cf ASSOCIATED DEPTH IN POND WQV=J 9,553 cf Ks =1 7132 b=1 1.1735 NWSE =1 854.00 ft Date: 2/13/2019 Calculated By: K. Gallt Depth of WQV in Pond = 1.28 ft = 15.39 inches Elevation = 855.28 ft Spillway must be set above this elevation 'J MCADAMS WATER QUALITY VOLUME DRAWDOWN CALCULATION Project Name: Brookside Project Number: RYN-17010 Facility ID: SCM C DRAWDOWN DESIGN Using falling head Orifice Diameter = 1.25 inches Number of Orifices = 1 Orifice Coefficient, Cd = 0.60 0.043 Ks = 7132 21,529 b = 1.1735 0.041 NWSE = 854.00 ft WQV = 9,553 0.039 WQV Elevation in Pond = 855.28 ft Date: 2/13/2019 Calculated By: K. Gallt Average Incremental Incremental WSEL Storage Siphon Flow Flow Volume Time [ft] [cf] [cfs] [cfs] [cf] [sec] 855.28 1 9553 0.045 855.17 8596 0.043 -.044 956 21,529 855.06 7656 0.041 0.042 941 22,251 854.95 6732 0.039 0.040 924 23,082 854.84 5827 0.036 0.038 905 24,055 854.73 4942 0.034 0.035 885 25,220 854.62 4080 0.031 0.032 862 26,655 854.51 3244 0.028 0.029 836 28,493 854.40 2439 0.024 0.026 805 30,986 854.29 1672 0.020 0.022 767 34,701 854.18 955 0.015 0.017 717 41,349 Drawdown Time = 3.22 days DRAWDOWN DESIGN Using average head Average Head on Orifice = 0.410 inches Orifice Coefficient, Cd = 0.60 Area of Orifice = 0.009 sf Flowrate, Q = 0.026 cfs 2-5 day drawdown required Drawdown Time = 4.21 days 2-5 day drawdown required 'J MCADAMS Subsection: Elevation -Area Volume Curve Label: SCM C Elevation Planimeter Area Al+A2+sqr (ft) (ft2) (acres) (Al*A2) (acres) Return Event: 2 years Storm Event: 2 year Volume Volume (Total) (ac -ft) (ac -ft) 854.00 0.0 0.110 0.000 0.000 0.000 854.25 0.0 0.158 0.400 0.033 0.033 855.25 0.0 0.185 0.515 0.172 0.205 856.00 0.0 0.207 0.588 0.147 0.352 857.00 0.0 0.236 0.664 0.221 0.573 858.00 0.0 0.267 0.755 0.252 0.825 859.00 0.0 0.299 0.849 0.283 1.108 860.00 0.0 0.333 0.947 0.316 1.424 BROOKSIDE RYN17010.ppc K. GALLT 2/13/2019 'J MCADAMS Subsection: Outlet Input Data Label: Composite Outlet Structure - SCM C Requested Pond Water Surface Elevations Minimum (Headwater) 860.00 ft Increment (Headwater) 0.50 ft Maximum (Headwater) 866.00 ft Outlet Connectivity Structure Type Outlet ID Direction Outfall El E2 (ft) (ft) Orifice -Circular Orifice C Forward Culvert 855.30 860.00 Inlet Box Riser Forward Culvert 858.50 860.00 Orifice -Circular WQ Orifice Forward Culvert 854.00 860.00 Culvert -Circular Culvert Forward TW 851.00 860.00 Tailwater Settings Tailwater (N/A) (N/A) BROOKSIDE RYN17010.ppc Return Event: 2 years Storm Event: 2 year K. GALLT 2/13/2019 'J MCADAMS Subsection: Outlet Input Data Label: Composite Outlet Structure - SCM C Structure ID: Riser Structure Type: Inlet Box Number of Openings 1 Elevation 858.50 ft Orifice Area 16.0 ft2 Orifice Coefficient 0.600 Weir Length 16.00 ft Weir Coefficient 3.00 (ft^0.5)/s K Reverse 1.000 Manning's n 0.000 Kev, Charged Riser 0.000 Weir Submergence False Orifice H to crest False BROOKSIDE RYN17010.ppc Return Event: 2 years Storm Event: 2 year K. GALLT 2/13/2019 'J MCADAMS Subsection: Outlet Input Data Label: Composite Outlet Structure - SCM C Structure ID: Culvert Structure Type: Culvert -Circular Number of Barrels 1 Diameter 24.0 in Length 57.00 ft Length (Computed Barrel) 57.01 ft Slope (Computed) 0.018 ft/ft Outlet Control Data Manning's n 0.013 Ke 0.500 Kb 0.012 Kr 0.000 Convergence Tolerance 0.00 ft Inlet Control Data Equation Form Form 1 K 0.0098 M 2.0000 C 0.0398 Y 0.6700 Tl ratio (HW/D) 1.151 T2 ratio (HW/D) 1.298 Slope Correction Factor -0.500 Use unsubmerged inlet control 0 equation below T1 elevation. Use submerged inlet control 0 equation above T2 elevation In transition zone between unsubmerged and submerged inlet control, interpolate between flows at T1 & T2... Tl Elevation 853.30 ft Tl Flow 15.55 ft3/s T2 Elevation 853.60 ft T2 Flow 17.77 ft3/s Return Event: 2 years Storm Event: 2 year BROOKSIDE K. GALLT RYN 17010. ppc 2/13/2019 'J MCADAMS Subsection: Outlet Input Data Return Event: 2 years Label: Composite Outlet Structure - SCM C Storm Event: 2 year Structure ID: WQ Orifice Structure Type: Orifice -Circular Number of Openings 1 Elevation 854.00 ft Orifice Diameter 1.5 in Orifice Coefficient 0.600 Structure ID: Orifice C Structure Type: Orifice -Circular Number of Openings 1 Elevation 855.30 ft Orifice Diameter 1.0 in Orifice Coefficient 0.600 Structure ID: TW Structure Type: TW Setup, DS Channel Tailwater Type Free Outfall Convergence Tolerances Maximum Iterations 30 Tailwater Tolerance 0.01 ft (Minimum) Tailwater Tolerance 0.50 ft (Maximum) Headwater Tolerance 0.01 ft (Minimum) Headwater Tolerance 0.50 ft (Maximum) Flow Tolerance (Minimum) 0.001 ft3/s Flow Tolerance (Maximum) 10.000 ft3/s BROOKSIDE K. GALLT RYN 17010. ppc 2/13/2019 'J MCADAMS Subsection: Composite Rating Curve Label: Composite Outlet Structure - SCM C Composite Outflow Summary Return Event: 2 years Storm Event: 2 year Water Surface Flow Tailwater Elevation Convergence Error Contributing Structures Elevation (ft3/s) (ft) (ft) (ft) 854.00 0.00 (N/A) 0.00 (no Q: Orifice C,Riser,WQ Orifice,Culvert) 854.50 0.04 (N/A) 0.00 WQ Orifice,Culvert (no Q: Orifice C,Riser) 855.00 0.06 (N/A) 0.00 WQ Orifice,Culvert (no Q: Orifice C,Riser) 855.30 0.07 (N/A) 0.00 WQ Orifice,Culvert (no Q: Orifice C,Riser) 855.50 0.08 (N/A) 0.00 Orifice C,WQ Orifice,Culvert (no Q: Riser) 856.00 0.10 (N/A) 0.00 Orifice C,WQ Orifice,Culvert (no Q: Riser) 856.50 0.12 (N/A) 0.00 Orifice C,WQ Orifice,Culvert (no Q: Riser) 857.00 0.13 (N/A) 0.00 Orifice C,WQ Orifice,Culvert (no Q: Riser) 857.50 0.15 (N/A) 0.00 Orifice C,WQ Orifice,Culvert (no Q: Riser) 858.00 0.16 (N/A) 0.00 Orifice C,WQ Orifice,Culvert (no Q: Riser) 858.50 0.17 (N/A) 0.00 Orifice C,WQ Orifice,Culvert (no Q: Riser) 859.00 17.14 (N/A) 0.00 Orifice C,Riser,WQ Orifice,Culvert 859.50 42.19 (N/A) 0.00 Riser,Culvert (no Q: Orifice C,WQ Orifice) 860.00 43.63 (N/A) 0.00 Riser,Culvert (no Q: Orifice C,WQ Orifice) BROOKSIDE K. GALLT RYN 17010. ppc 2/13/2019 'J MCADAMS Subsection: Level Pool Pond Routing Summary Label: SCM C (IN) Infiltration 857.07 ft Infiltration Method No Infiltration (Computed) 0.589 ac -ft Initial Conditions Elevation (Water Surface, 854.00 ft Initial) 0.714 ac -ft Volume (Initial) 0.000 ac -ft Flow (Initial Outlet) 0.00 ft3/s Flow (Initial Infiltration) 0.00 ft3/s Flow (Initial, Total) 0.00 ft3/s Time Increment 1.000 min Inflow/Outflow Hydrograph Summary Flow (Peak In) 13.30 ft3/s Time to Peak (Flow, In) 722.000 min Flow (Peak Outlet) 0.14 ft3/s Time to Peak (Flow, Outlet) 1,440.000 min Elevation (Water Surface, 857.07 ft Peak) Volume (Peak) 0.589 ac -ft Mass Balance (ac -ft) Volume (Initial) 0.000 ac -ft Volume (Total Inflow) 0.714 ac -ft Volume (Total Infiltration) 0.000 ac -ft Volume (Total Outlet 0.124 ac -ft Outflow) Volume (Retained) 0.589 ac -ft Volume (Unrouted) -0.001 ac -ft Error (Mass Balance) 0.1 % Return Event: 2 years Storm Event: 2 year BROOKSIDE K. GALLT RYN 17010. ppc 2/13/2019 'J MCADAMS Subsection: Level Pool Pond Routing Summary Label: SCM C (IN) Infiltration 858.53 ft Infiltration Method No Infiltration (Computed) 0.972 ac -ft Initial Conditions Elevation (Water Surface, 854.00 ft Initial) 1.508 ac -ft Volume (Initial) 0.000 ac -ft Flow (Initial Outlet) 0.00 ft3/s Flow (Initial Infiltration) 0.00 ft3/s Flow (Initial, Total) 0.00 ft3/s Time Increment 1.000 min Inflow/Outflow Hydrograph Summary Flow (Peak In) 26.42 ft3/s Time to Peak (Flow, In) 721.000 min Flow (Peak Outlet) 1.31 ft3/s Time to Peak (Flow, Outlet) 887.000 min Elevation (Water Surface, 858.53 ft Peak) Volume (Peak) 0.972 ac -ft Mass Balance (ac -ft) Volume (Initial) 0.000 ac -ft Volume (Total Inflow) 1.508 ac -ft Volume (Total Infiltration) 0.000 ac -ft Volume (Total Outlet 0.544 ac -ft Outflow) Volume (Retained) 0.964 ac -ft Volume (Unrouted) -0.001 ac -ft Error (Mass Balance) 0.0% Return Event: 10 years Storm Event: 10 year BROOKSIDE K. GALLT RYN 17010. ppc 2/13/2019 'J MCADAMS Subsection: Level Pool Pond Routing Summary Label: SCM C (IN) Infiltration 858.97 ft Infiltration Method No Infiltration (Computed) 1.097 ac -ft Initial Conditions Elevation (Water Surface, 854.00 ft Initial) 2.963 ac -ft Volume (Initial) 0.000 ac -ft Flow (Initial Outlet) 0.00 ft3/s Flow (Initial Infiltration) 0.00 ft3/s Flow (Initial, Total) 0.00 ft3/s Time Increment 1.000 min Inflow/Outflow Hydrograph Summary Flow (Peak In) 44.63 ft3/s Time to Peak (Flow, In) 721.000 min Flow (Peak Outlet) 15.96 ft3/s Time to Peak (Flow, Outlet) 731.000 min Elevation (Water Surface, 858.97 ft Peak) Volume (Peak) 1.097 ac -ft Mass Balance (ac -ft) Volume (Initial) 0.000 ac -ft Volume (Total Inflow) 2.963 ac -ft Volume (Total Infiltration) 0.000 ac -ft Volume (Total Outlet 1.995 ac -ft Outflow) Volume (Retained) 0.966 ac -ft Volume (Unrouted) -0.001 ac -ft Error (Mass Balance) 0.0 % Return Event: 100 years Storm Event: 100 year BROOKSIDE K. GALLT RYN 17010. ppc 2/13/2019 'J MCADAMs RIPRAP OUTLET PROTECTION Project Name: Brookside Date: 2/13/2019 Project Number: RYN-17010 Calculated By: K. Gallt Facility ID: SCM C cfs DESIGN OF RIPRAP OUTLET PROTECTION 3.00 in Calculations based on NY DOT method - Pages 8.06.05 through 8.06.06 in NC Erosion Control Manual. Flow, Qio_N= w 1.31 cfs Slope = 1.75 % Pipe Diameter, D.— 24 in = 2.00 feet Number of pipes = 1 13 Pipe separation = 0.00 feet Manning's n =1 0.013 23 Zone from graph above =1 1 Figure 8.06.6.1 4 5 6 7 8 9 10 Pipe diameter (ft) Outlet pipe diameter =g4..78 4 in Outlet flowrate =31 6.00 ft cfs Outlet velocity = 3.00 in ft/sec Material =s A Zone Material Diameter 1 Class A 3 2 Class B 6 3 Class 1 13 4 Class 1 13 5 Class 11 23 6 Class 11 23 7 Study Required Length = 8.00 ft Width = 6.00 ft Stone diameter = 3.00 in Thickness = 9.00 in Thickness Length Width 9 4x Da 3xDo 22 6x Da 3xDo 22 8x Da 3xDo 22 8x Da 3xDo 27 10xD. 3xDo 27 10xD. 3xDo CULVERT DESIGN CALCULATIONS BROOKSIDE SUBDIVISION RYN-17010 uo '16 _ y } CgC � " . • ,. 0� o UmF 0 CgE + M }# . CD w. N cE - ' � ' • '- LuC CeC�2 PGD2 4 r -� Cg r-- L Md6 n- CeB2 ChA� LCD Ce62 Hydrologic Soil Group—Iredell County, North Carolina (IJoCulvert) MAP LEGEND Area of Interest (AOI) Area of Interest (AOI) Soils Soil Rating Polygons 0 A 0 A/D 0 B 0 B/D C 0 C/D 0 D Not rated or not available Soil Rating Lines r r A r r A/D r B B/D r r C 0 C/D r r D r r Not rated or not available Soil Rating Points 0 A 0 A/D B B/D MAP INFORMATION p C The soil surveys that comprise your AOI were mapped at 1:12,000. 0 C/D Please rely on the bar scale on each map sheet for map 0 D measurements. p Not rated or not available Source of Map: Natural Resources Conservation Service Water Features Web Soil Survey URL: Streams and Canals Coordinate System: Web Mercator (EPSG:3857) Transportation Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts Rails distance and area. A projection that preserves area, such as the #%-0 Interstate Highways Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. US Routes This product is generated from the USDA-NRCS certified data as Major Roads of the version date(s) listed below. Local Roads Soil Survey Area: Iredell County, North Carolina Background Survey Area Data: Version 23, Sep 10, 2018 ® Aerial Photography Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Apr 8, 2015—Nov 28, 2017 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. UUP Natural Resources Web Soil Survey 11/12/2018 Conservation Service National Cooperative Soil Survey Page 2 of 4 Hydrologic Soil Group—Iredell County, North Carolina Hydrologic Soil Group 1 J Culvert USDA Natural Resources Web Soil Survey 11/12/2018 Conservation Service National Cooperative Soil Survey Page 3 of 4 Map unit symbol Map unit name Rating Acres in AOI Percent of AOI CeB2 Cecil sandy clay loam, 2 B 6.8 2.2% to 6 percent slopes, moderately eroded CeC2 Cecil sandy clay loam, 6 B 12.2 4.0% to 10 percent slopes, moderately eroded CgC Cecil -Urban land B 143.3 46.6% complex, 2 to 10 percent slopes CgE Cecil -Urban land B 23.8 7.7% complex, 10 to 25 percent slopes ChA Chewacla loam, 0 to 2 B/D 6.2 2.0% percent slopes, frequently flooded LcB2 Lloyd clay loam, 2 to 6 B 5.2 1.7% percent slopes, moderately eroded LcC2 Lloyd clay loam, 6 to 10 B 8.1 2.6% percent slopes, moderately eroded LcD2 Lloyd clay loam, 10 to B 0.8 0.3% 15 percent slopes, moderately eroded LuC Lloyd -Urban land B 16.8 5.5% complex, 2 to 10 percent slopes MdB Masada fine sandy B 1.8 0.6% loam, 2 to 6 percent slopes PaE Pacolet sandy loam, 15 B 3.1 1.0% to 25 percent slopes PcD2 Pacolet sandy clay B 8.3 2.7% loam, 10 to 15 percent slopes, moderately eroded PcE2 Pacolet sandy clay B 7.5 2.4% loam, 15 to 25 percent slopes, moderately eroded UmF Udorthents-Urban land C 63.8 20.7% complex, 0 to 45 percent slopes Totals for Area of Interest 307.7 100.0% USDA Natural Resources Web Soil Survey 11/12/2018 Conservation Service National Cooperative Soil Survey Page 3 of 4 Hydrologic Soil Group—Iredell County, North Carolina Description Hydrologic soil groups are based on estimates of runoff potential. Soils are assigned to one of four groups according to the rate of water infiltration when the soils are not protected by vegetation, are thoroughly wet, and receive precipitation from long -duration storms. The soils in the United States are assigned to four groups (A, B, C, and D) and three dual classes (A/D, B/D, and C/D). The groups are defined as follows: Group A. Soils having a high infiltration rate (low runoff potential) when thoroughly wet. These consist mainly of deep, well drained to excessively drained sands or gravelly sands. These soils have a high rate of water transmission. Group B. Soils having a moderate infiltration rate when thoroughly wet. These consist chiefly of moderately deep or deep, moderately well drained or well drained soils that have moderately fine texture to moderately coarse texture. These soils have a moderate rate of water transmission. Group C. Soils having a slow infiltration rate when thoroughly wet. These consist chiefly of soils having a layer that impedes the downward movement of water or soils of moderately fine texture or fine texture. These soils have a slow rate of water transmission. Group D. Soils having a very slow infiltration rate (high runoff potential) when thoroughly wet. These consist chiefly of clays that have a high shrink -swell potential, soils that have a high water table, soils that have a claypan or clay layer at or near the surface, and soils that are shallow over nearly impervious material. These soils have a very slow rate of water transmission. If a soil is assigned to a dual hydrologic group (A/D, B/D, or C/D), the first letter is for drained areas and the second is for undrained areas. Only the soils that in their natural condition are in group D are assigned to dual classes. Rating Options Aggregation Method: Dominant Condition Component Percent Cutoff. None Specified Tie-break Rule: Higher 1 -To Culvert uSDA Natural Resources Web Soil Survey 11/12/2018 Conservation Service National Cooperative Soil Survey Page 4 of 4 'J MCADAMs POST DEVELOPMENT HYDROLOGIC CALCULATIONS Project Name: Brookside Subdivision Date: 11/27/2018 Project Numbei RYN-17010 Calculated By: K. Gallt Subbasin ID: 1 -To Culvert SCS CURVE NUMBER (REF: TR -55 and NRCS Web Soil Survey). HSG'A' _ HSG'B' = HSG 'C' = HSG 'D' = Cover Composite Condition SCS CN Comments 1/4 acre lots 77 1/2 acre lots 72 Multi -family 86 Industrial 89 Assume good condition Commercial 92 Assume good condition WATERSHED BREAKDOWN Composite Area Area Contributina Area SCS CN Isfl tacresl Comments Onsite 1/4 acre lots 77 1,172,174 26.91 Offsite Multi -family 86 164,053 3.77 Offsite 1/4 acre lots 77 10,184,707 233.81 Offsite 1/2 acre lots 70 114,558 2.63 Assume 100% HSG B Offsite Industrial 89 503,895 11.57 - Offsite Commercial 92 1,259,538 28.92 Total Area = = Composite SCS CN = % Impervious = 13,398,925 sf acres 307.60 79 43.92% TIME OF CONCENTRATION Segment 1: Overland Flow Segment 2: Concentrated Flow Length = 100 ft Length = 859 ft Upstream Elevation = 952.00 ft Upstream Elevation = 947.00 ft Downstream Elevation = 947.00 ft Downstream Elevation = 906.00 ft Height = 5.00 ft Height = 41.00 ft Slope = 0.0500 ft/ft Slope = 0.0477 ft/ft Manning's n = 0.40 wooded -light underbrush Paved? No P (2-year/24-hour) = 3.42 inches (Troutman, NC) Velocity = 3.52 ft/sec Segment Time = 1 14.40 Iminutes Segment Time = 4.06 minutes Segment 3: Channel Flow Length = 4417 ft Upstream Elevation = 906.00 ft Downstream Elevation = 833.00 ft Height = 73.00 ft Slope = 0.0165 ft/ft Manning's n = 0.045 natural channel Flow Area = 16 sf (assume 4'x4' channel) Wetted Perimeter =12 If (assume 4'x4' channel) Channel Velocity = 5.16 ft/sec Segment Time = 14.28 minutes Time of Concentration = 32.74 minutes SCS Lag Time =1 19.64 Iminutes 7i 00 -1 1 1 1 N� \ I N, N' IN 1 1z ------------------------ - - ------------- fIN, ----------------- IN - -------------- -- -------- --------- - IN, J, - - - -------------- ------------ N, IN - - ----- --- ---------------------- - ---------- - --------- -- ---- ----------- It 000 > ---------- ",, 'N, -- ------------- it N, \\�"'X', ---------- ---------------- -------------- -- --------------- ------ ------------------------ 41N ------------------ was - --------- *to ------- - -- - ------ 'N N,, ------ - i f X// --- ---- -------- ------- N, - ---- ---------- ---------- - ------------- - ------------- ------- -- ------------- ------------ ------------------- - ----- - ---------------- ---------- IN --------------- ---: , " ------------------- ------ ---- --------------- -------------------------------------- ------- ----- - ----------- ----------------- ------------ ----- ------ ---- ----------- -------------- ------------- ------- --- -------- -------------- NN, - ----- IN IN 'N\ -- ------ -- ---- it IN ----------- ------------ IN "N __: ---------- ---- ------ N, ----- --- --- --- N, ---- ---- ----------- N� --------------- ----------- ----------- - - -------- --- --- ---- --- N\ IN, N,,:", NII\ J --------------- ----------- -- ------------ ------ - --- - ------ -- ----- NN -------- . � NN, - ----- -- IN N NIN -- --------- N,\ IN, I " N� IN, ---------- N� ----- ---- --------- -- --- ----------------- z ----- ----- ------ . ........ ---- -- -------- -- - -------- - ---- -N' -- , , , , , / - ____ ___ _- ___- __ - \� I\ - -_ - , :: ----- "' i, ""', � 1 I� /, , -- , \ " I -------------- - -------- ------ - _1 ---------- ------------- ---- -- --- - ------ ------ -------- --- -------------- ----------------- ------- ------ - ----------- ------------ - ------------ ------------ ------------------------- -------------------------- --------- - -- ---- ---------- --------------------- X -- ------ --- ----- --------- - -- - - --- . . . ------- ---------- N' IN N, ---------- --- --------------- ----------- : ---- --- ------------ :: - -------------- - ------------------- ------------------- - - IN, 'N, - - ------------ - ---- _­ MIV ------- N, iN r ------ -------------- N N,N, ------- ------- --------------- ---:: -------- --------- - ----- - ------------------- ---- ----- ----- ---- - -------- - ------------- - -------- ------ J I /Z ------- --- ----- ------- fli------ ---- ---------- ___ - ___ , ", / -- - - ----------- --- - -------- - - -- -------- - - - ----------- -- - -------- - ------------------ -------------------- \N, ------------ ------------ -- IN, \,NNN\'\1,:1 - - ----------------- --- - ----- ------ -- - ------ Z-3 --- -------------- ---------------- -- IN, j ------------ ---- ---- -- .... - -- ---- z - ------- 7 ""X ------- `N N, -- ---- ------- ----- --- - - --------------------- ---- - - , / , \' , __ \ I \� , " - -------- ---------- " \ ., I \ - / I ", \,\ \" 'v, -- --------- - IN I N, ---- ---------------- -------- - -- - ------ `N\ N\ f- ------- --- it ,NN, ------ - -- ///Z, ------------- ------- N, IN IN, ........ ------- j);) f1h, --------- "N - ------------ ----------- Z -- - ---- -------- IN, IN IN IN, ------------ - > if It ::: ) I ` , , , z; IN\ NL < ---------- N) if N, --- ---- -- - ------------------ -- - --------- If - ------ --- ------------- IN, -------------- ------------ r --j - -- -------- - ---------------------------------- ---------- it --- - --------------------- -- IN, ---------- IN N IN, ------- --- ------ IN IN, Q IN ------------- 0 -- - -------- ------- - ------ N, N IN N\ I'if// If if if t 1 IN lif ------------- 11P - --- ------ --- --- ----------- N `N, 1 1 'Y"( L� "I ... / "", // / --- , , , , , / , , "I'll, 11 11 1 1 \ \ `\ IN \ I, IN, ------------- -------------- ", ", ", 11 1 , /"" , , , I - --------------- -- N, if it, ft if IN, (6 ----- - - ---- --- - - ------ ---------- ------- ----------- / , , , , ­, "i � 1 `� \, IN, of, -------------- -- --- :: Vf/, '/lb" ------ ------- ------------------- -- -- x" - ----------- N`111 IN \ I IN, ", `� �� \ ", i 1 l i ) J "I'll "IN IN ------------------ ------------- --- -------- --- ------- IN N, J/ - ------- J i Uill' # --------- - It , it N\ ----------- "I ON If ------------- `NN\ ------------- .. ....... - ----- N\ - ----------- ------------ N, IN ---------- ------ Z z z -- --------------- ---------- ---- M A "N, / " ", �/// 11 / 11 It i// ---------------- - ---------- ------------- ---- lit I Oil, N, IN, -- -------- ----- IN N\ ---------- ---- VNV"Ni C ----------- -------- z-- - ----------- N", --------------- ------------- :::::-- - - ---------- - - -------------- ----------------- ------- It il --- ---------- -- z � "N'' , , i i \ \, ,, ) / , N, IN 0 --- ------ --------- --------------- --- -- - ---------- ----- - IN IN IL ------ --------------- Z, IN ------ --------- - - ----------- - - N1 `NN , \ \� �N. -- --- ----- "N N);, 1 j ---------- N� ------ -------- ---- < ------- ---- ---------- t/,/_ X it "', If / ,, /,/ "i i --- z it NNN "N' Nk---------- --------------- - - -- --- ---------- -- -- -- --------- IN ------------ N N, N, ------ --- - ---------------------------- ----- ---- 0 -------------- -- - --- - -------- it fit ---------- N"I" ..... I N, N\ , 0, - -------- - -- ------- - - ------------- z` ',I'N'\\'N\`I I NNN,\""\\-\\` N; , N� IN, ------ ------ - -------- IN '0 ----------------- N� ---- "I I ", ", ---- z ------ ------------ Ni ----- --- ----- -- z A- -------- if 11, ;I;!( �IIIIWANNMI N\ V\, IN, IN X:, N �,i, ....... IN-------------- N, -- --------- ''Al -- ------------------------ ------------------- - --------- IN ---------------------- it 'N\ ------ ----------------- -------------- I � i i ! . . . -- - ------ - ---------- ___ --- I I , , " " \ , \, 11 \ \ �, , \ , N, -------- - IN --------------------- - ------ -------------- J, Z "":", J/ ------ - --------- ------- --------- \ " ,, , \­\"� J, - "'i ". i N., IN,\ "N\ ------ ---------------- J, _:�� ----- - -- ------ ------ IN ----------- ----------- 41 , , , , j , - ,, "/ �<�_ , -,, , N, It ----------- ----- ------- - ---------- `N ----------- N-------- ------- IN ------ ------------ I ------- I if ------------------- ------- - ------------------ "VI N, - - -------- -- ------------- ------- V, I/ IN NI IN, gg,�,, N, N' - ------ )IN N\,\ - -------------------- --- -- - -------- ------ - - ------- ---------- --------------- ------ ------- - \N,\ N, 4" N, V\ 'N' 'IN 1 xl� j ---- ----- - ----------- ltW0'\NN\ it N\ -------------- I ""vilp""'N' I N� Z --------- N, "'A 1" X IN iN i t f 1 - -------------- olmlh i 1 i i J) l I I IN,\ " %, , - Z,z IN N, ----- ------ A\ N N i A N\ - ----- "'XV, - - --- 1, " X'i, MW""A" ------ --- IN * \ ___ ____ __ ____ \ /" I /, ------------ ---------- -, ,- 1 "', ", I , , , , j - - : \�', l�,Z -Z IN, --- - - ---------- N, ", \ N, " \\ ", , \ \N_ 1, 4t# N, `0 \ \v, N' ----------- ---------- - . ......... Nl IN ---- --- --- ---- N, N" ---------- - - ------ --- ----------- ------------------------------- - , , 1 1 1 � - / ( �\\ ---------------- : ------------- J- ---------------- --------------- -- ------------ 1 ---------------------------- --------------- W, ----- ----- fill 'i'li, 'N", X/ I N) ------------------- --------------------- ------ C\\ --- - ------------- - - -- - ----- - --- -------------------- N\ N\ 1, N, -------- -------- ----- -------- ------ ----------- IN ----- ------------------- -- ---------- -- --------- N, --------- -------------- -- --------------- ------------ r N, IN, 307.60 AC,,, - -------------- `INN\",\N' SUB 1- To Culvert 1 � (h., (I ------------------- ----------- ... '61 111",""OH11 NN, ------------- ---- ------ --- ------- . . ... ..... N, z r ... :NN NI, ------ --------- -------------- ----------------- ----------- - ---------------- ------- ----- -------- ---- - ------------ IN, ------- --------- - ----- ---------- ------ ------------------------ -------- ---- -- .. NN .............. .. ------ --- ---- ----------- - - - - -- - --------- it ------------- ---- 0 N, ) I , ) N`_ > IN -NN, N) "(11 1 N -------------------- lN`Olo -- ------------------------- --------------------- IN If N, N, if I it ------------ N\ ') ) ) , "' �/' " \ I I. ) 1 1 ) j , I ) " 1'� , " I" I __ -------------- N IN, N' -------------- , \ V , `Q\ IN, ------------- I i i i 1 ! ------------ N) It - -------- --------------- # 44P --------- 'X If --- - -------- IN, ---------------------------- * zt, IN ----------------- \N ------ ------------------------- ----------- N, ---------- jr) ------------- ------- 1 1 N Z ---------- I - ------------- Vv, N�, N, N'i, � , , " \ --- i IN\, I :it i fN - ----- ----------- x\ N\ 'IN A ------------ ------------ All % 'Z --------------- - ---- ----- IN l,J) ----------- ------ --------------- :7 J)", ------------ - ---------- 1� J., -- - ----- --- ------------------------------------------ --------------- IN, ------------- NN, "',N"", ON,\ A 1W, ---------- --------- - N, NN - --- ------- ----------- - - --------- N, v -- - ----- N, ------ --- - l'N f ------ :--: ------------------ - ----------- 1\ N, IN, ------------------------- IN N\ "IN ---------- N\ --- ----------- IN --- ----- ------------ X IN, -- ----------- - --- - ---------- - - ------------ ------- it N I ------- IN - -------------- - ----- ------- ---- - ------------- ----- ----- 7 IN ---------- N 'IN - --------- - --------------- N, ----------- ----------- - N\ N --------- -- ------- ---- - --- ------ N. if - ------- t IN, ------ N,\ IN ------ - -------- if ---------- ;:­,, --------------- N, -- ----- -- ------------ - ----- ------- - - ---------------------------- - \N, ------ lit, ---------- IN I M! 1/h, f I - ----- - ------ ---------------- IN- ------------------------------ --- --------- --------------- ------------ -- ------------------------------- - ----------- ------------ __ \,\ - " , I ... 1 1 1 lll ! ,, I, / ,,, , , , 'N, ------- - ---- \,\NNN:N,,:N, h' IN r - I / , I"// , / /, �/ "I "I 1 -1 1, " N, it �/ i I iiii ! i i z t N;\,, -------- --------------- - ------ f IN ---- --- ---- ---------- N \N, IN Z11 - --------- ----- --------- "Z ---------------- ------ IN, j - -- --------- I IN --------------- X"'I'N" if ----------------- ------------ N, ---------------------------- ------- ....... If N,, --------------- 'N, ------- IN \ \,---____--� -,' -- -:�:: -------- IN, if 'N" ----- --- i: --------------- -- --------- - ----------- N, -------------------- ----------- IN------------------------------- ------- N I - ------ i i i IN 'N' 'A IN N, - --------------- -)`NN, :: ----------- , I- ",_1 0 -, -- I I I --------- N, - - - -------- - -- :-\ \ \, _­ "' ---: __ i 1, NN N, X - ------------- - ---- ------------------------ - --------------------------------- --- - - ------------------- - N, I � l - ---- - ------ , I \ , , --------------- ------------- -- - ----------------- - ----------------- :: -- --- --------------------------- ,,,\,�NN'IN\A N' ------------ N`NN -------- - - ----------- --------------- ------ IN, - - ----------- ----------------- - J IN ------------ - : I, - __ , ! ., I li ---- ------------- z --------------- 1 1 ­__ I I I I , , ) , -- - - __ " NN ------------- ------------------- - -------------- -------------- _::_ __ 1 If , , '' "'' \ --------- -- Z ----------- ------- ------- NVAN, �\i N, I -- -- - ------ X -------- - - Z, -------- # -------- ------ / . . . . . . . . J, --------------------- / " " / / ,, " i " ", it ------- it IN, ---- -- r z ------ it ---------- \N ------ A/ IN, ------ - ------- -- 5 - -- ---------- :: ------ -------------- If ----------- ------- ------- 7 IN " \ I i I - , 'I, --------------- ------- -:-:: --- ----- N, - --------- ---------------------- - ----------- ------- - - ----- -- ----- ----- - -- ------------- - --------- -------------- --- ------- -- -:: " � �! - - -------- - N, \ , \ , /1 1, 1 ,, \ - --- : - 'J" -------------- -- ------- -------- -------- if 0 --- - ------- �:! if �­"',N\ INN - --- ------- - - - ---------- - ------------- N\ N, 4V -- ---------- Z, ---- -------- - ---- -- ---------- Ml!!Wli 1 - -- --------- --- ------------- --------- ---------- ------ --- - - ---- --------------------------- ------------- - --------- j ------ ----- ::Z� ',NN\\<\, 0 --- --------------------- --- " --- I - - -- ------ ------------ N, -11F ----------------------------- - ------ il it if I' --------------- " i ! � ---------- fN IN ---------------- llillil�o, "', "" --------------- ------- Z - -------------- - - ---- : - ------ -------- - -------------- - J 4# " t k ", k", "N N\ "x :,",""N"N" N\ IN, W N ----------------------- -- --- 'N, IN IN, ",/I __NINN,\`, --------------------- it IN V., --- ------- - z�, --- ------------------------------ ---- ---------- - ----------------- ------- i if t --------------------- - --------------- V- ---------- ------------ I IN - --------- ---------- IN , , I \ I ; ! I ", / " " i , , /� 1\ \1 ll i1N ',I \1�, N\ i (, , , , , IN -------- - - , , , " , \ -, N, - I -- -------- X// " " " I, ,; I ", , , , , 1 1 1 , , , / I I - I" -, � � 11 ", ", // ,, "; / ", " " -1 " 1, 1 / z - ------ V0 , , " , / \ , ---------------- f I ij Ir , - , / � ) 4 - , , '\ N, - ---------- \ --- , , , " � !N� ------- \ " � �-� 4-' v ------- -------- /z` If li XV, ------------- - -------- 'N f ------ - ---------- If If M V NL A ---------------------- --- --- - N, - ------ --------- - - ---- ------------------ A ----------- ----------- 'NN, N, it -- ----- --- - -------------- ...... -------------- - -- ------ ------------- q V", Z - , , , Ill/ I.- / ,, /,- , / , , , , , / 1 1 \ \ - , \�'il ----------- --------- ------ fo "; 1; 1, ", / -- / ---------- 01, 1 N\ VNI IN, N. ---- -------- - ----- N%, ------ - ---- J_ - / "I jot___ Al U, \\N NA � � i ,, ! NL ---------- -- - ------------ X I ----------- NN') ------ if I, it " �10(f, , -� " "w"W, I J 11 WON\\ if I I /" - 11 1 " ", 4 i ( // If / l , \NN", , \IN\, \ \ I " ---------- --------- fir fit, N\ f IN VIN it (,Vmi!� wil!Ill N' ill CI lM .... -------- ------ - ------ V\ t........... N, 1, " "", - i ii 1 if I ! 1, - // ", \�_ �' ", 1 1 !,m j"i I., � ", \ ", � H I / : 4 , U, ---- - -------- " j i i i -1 1 1 1 ", `-, i (" /, if I 1 1 1 1 IN, it 1 -4 ,,, "" \, " "�_ --------------- - N, I Z -- -------- it J11111i ill 11 P� \;\:":, , � 1;�, , "L, I \ I " , \ \ I , , , \ " '. ` . \ \",, \'�,,'­,-,� -- ---- ------------- 1A "IN "IN N, - -- - ---------------- ----- -- -------- I N, ith 1 1 " --- \ i if - ZI/11,/// ........... ---------------- --- ----------------- ----- - - ------------- J IN, --------------------- --- ---------- I N ----------- ---------- ------------------ "'N NN, ;/1;l;i:M1i1t1,, No"', - -- ---------- N, "V ------------------- l!Hl(M ____ ��// "I "' /tIW1 IN j N ------- --- ------- N N ------------ - -- IN' If J I ---------------- - - IN if ---------- Hill --------- - N,;,, N, 1, ON IN-- -------- f i 1 j I \ " " I " \ -, � - ____ - , " I - ------------ N' --------------- IN 4 IN,\ - ------------- N), --------- - N, N, ------------- if----------- ft i k ----- - -- N1, J i_ 4# ------------- - ------------- -------- I IN N If lit/11 ---------- i V� N1,\X,,, IN\ /18 ---------- I/0 --------------------- --------- ------- ---------------- - N,\ NO, it ------- ......... . . ----------- i If I z t ---- ---- ----- It --------- - ------ ----------- - it i It \NN ----------- Z ------------- J 1 x ---------------- k N, I, Ni h ; j � 1 1 \, - ---- - - - ------------ ------- 'N\A , , I , \ `N____ , 1, N, - -- -- ------- fill - -------------- ------ If III Ill --- --------- ---------- N, N� I N,N, ,I - " ,, 11 ---------- X --------- -------- It I IN 1 1, 1 1, 1, N, I -------- -1 -------------- - - - - ------------ ; --- --------- -- IN ------- - ---------- N N : -- - --------- ---------- N\ j - --------------- --- \UlM 1 _­ < )h gg I if I Z ---------- - " \ , I -_ � ­� ------------------------- N; I, I 'IN -Z"", If --------- `N\ ---------- 0� IN N, ------------------ it if - ------ ---- �_: ------- IN ,N IN, it -- -------------- it i i fl) ill N. N MON oil 1 J) )Ill! 11 W 1 / / ''., 1 !;; 1 '' V\1 A -- --------- IVNI 'N�N\ z "N' IN IN N\N`\,N`1"1'1 IN � N, " IN ,, � l \, " X 1", 11, \ \ "I I \ / / ... I, ... NVII'11"`,��Vl��li d ll�iim VIN z N, ------ It "i ft N, I, 1\ - ------ ON I, i iIi�it::111111'0 I z z-, V, "N, I --------- A� IN` , - i IN ''I ... I - ---------- N\\\ N, i NN, -------- - -------- --------- N\, 1 IN - ------- -------- - - -------- V, ---- -- N, I It I j N\ it / (",// " 1 ) � , �, \,,,\��­",", ,, ------------ - - - ----------- <: ---------- �X INX ---------------- ---- it z `N,NN� ...... - - ---------- 0 "\'IXNA, - - - ------------ V IN, ----------- ---- N, \N, \A\""',� ---------- ---- -------- ------ NN l, i, N ---------- IS ---------- N, .......... `NVNN,`, ----------- - I, IN N, X, - ----------- -------- t-7 -- --------- 0 16 10 0"Ift ij 0 0 --------- ---- ------- ------- A., IN ---------- 7� \N`N1 IN x,- , ..... ------ - ------- - ---------------- , , "I I; I I I . ; v , " I- - - - 1 i 11 �Ml 1 ........... . If ----------------- - -------------- ...... wl ------- ...... it -- - ------- z ------ ------ "'44, ------------- Nll�l, --- ----- �NI ---------- --- - ------ fit I" ---------- __ - , I, - .1 - , lM, IN ----------- ------- j, -------- ------ -- -------------- -- IN r V", X 1z NC GRID (NAD83) PROPOSED CUL'U'EKI ---------- ""I'll I if I l, 1, 1 -- -------- I- - -------------- , /, - - 1� i 11) Ill'', I --, ----------- ----- --- ----- ---- ------ --- ------------- ------ ----- - ---------- ------ --- i - ------- f l 1 '�'NIN,-, "\"X`N, jq/ll; 1 If --------- - : ---------- --- - - ----------- ------------- - , / I ! 1 1 / // , " , , / ___ , , , , - I � . , 1 1)',) " N - ----- - ------ ---------- z -------------------- PROPERTY LINE ------------- - - ------- ---- ------ - - , , , - , / , ------- - - - -------------- -------- ------ N,�,! ------------- ��j,l/ - - ------ -------- ------------- - --------------------- - ---------- - ---- -------- - - ----- -- ------ - - - ------------- --------------- -------------- -- - ----------- - N\\ ---- ----- i H! fifil - ------ ---------- AN' h., IN\ - - - -------- ------- - - -------------- i i i iiil�ll - - -- ----- -- - I - --------- '\"NNNN­ ------- it 1 lllwww­ - ----- X, - ----- ----- SITE AREA 57.80 AC GRAPHIC SCALE 11 -Z: iiiii! fit ----- -- ----- --------------- ----- -- ------------ ------- � i i ( '�, ", I, " ", \ ,�, �,\, i, i, � ­:Z�_-__- , 1 / I , - 1, 1 --- , , , / --- 1 1 / ------ 0 150 300 600 -------------- - ----- IN .......... - - ---- --- -- - ----- --------- ----- --------- - -- .......... I V - -- ----- N < N it z- ------- - --- ----------- ------- IN --------------- NN IN, I, L V,�X\", ------- ---- -------------- ----------- ------ IN, z , / I, ", I,/ I ", ", , I I t __ ____ __ -- ---- -------- -------- ---- N, IN 1 1, ::�_: --------------- �NNN,"­---- 1 inch 300 ft. I It : ------ NN, IN, - ---- ---- IN, A N IN, .... ..... ----------------- -------- ----- 1 11 i 1 1, -_ - _ , --------- _5 hit ---------- ------------- - - --------------- - IN, , , , - 1 ------- - � 6 I, NN X ;!Ild -------------- - --- ---------- -- it NN - ------- - ------------ ------------- -------- IN. NN �N It ii IN, t J FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com CLIENT NASS CROSSING, LLC 7620 RED BAY LANE PARKLAND, FL 33076 ATTN: MATTHEW WILSON, MANAGING MEMBER U) (D 1,D 00 0 � --- LLJ RYN17010-DA LOU U Z) LLJ KRG SCALE < DATE 2 SHEET U ) 0 = Z LLJ < 0 U U (D 0 � --- 00 RYN17010-DA CHECKED BY U Z) LU KRG SCALE 1"=300' DATE 2 SHEET Z 0 0 U REVISIONS NO. DATE PLAN INFORMATION PROJECT NO. RYN-17010 FILENAME RYN17010-DA CHECKED BY JAA DRAWN BY KRG SCALE 1"=300' DATE 11.26.2018 SHEET CULVERT DESIGN DRAINAGE AREA MAP DA HY-8 Culvert Analysis Report Crossing Discharge Data Discharge Selection Method: Recurrence Table 1 - Summary of Culvert Flows at Crossing: Crossing 1 Headwater Elevation (ft) Discharge Names Total Discharge (cfs) Culvert 1 Discharge (cfs) Roadway Discharge (cfs) Iterations 837.56 25 year 716.51 716.51 0.00 1 839.34 100 year 918.68 918.68 0.00 1 862.50 Overtopping 2226.22 2226.22 0.00 Overtopping Rating Curve Plot for Crossing: Crossing 1 880 876 :Z 870 866 aD 860 w a' 866 860 aD z 846 840 Total Rating Cie crossiRg: Crossing 1 Total Discharge (cfs) Table 2 - Culvert Summary Table: Culvert 1 Discharge Total Culvert Headwater Inlet Control Outlet Flow Normal Critical Outlet Depth Tailwater Outlet Names Discharge Discharge Elevation (ft) Depth (ft) Control Type Depth (ft) Depth (ft) (ft) Depth (ft) Velocity (cfs) (cfs) Depth (ft) (ft/s) 25 year 716.51 716.51 837.56 8.500 10.062 7-M2c 7.918 5.809 5.809 3.776 13.705 100 year 918.68 918.68 839.34 10.713 11.842 7-M2c 9.000 6.856 6.856 4.290 14.889 Straight Culvert Inlet Elevation (invert): 827.50 ft, Outlet Elevation (invert): 827.00 ft Culvert Length: 66.00 ft, Culvert Slope: 0.0076 Culvert Performance Curve Plot: Culvert 1 8 C, iui LJ Perfol711a11ce Curve cuh-ert: cuh.-ert 1 0 0 Inlet Control Elev Outlet Control Elev 8F10 45 aD I 840 835 D 1400 1000 Total Discharge (cfs.) Water Surface Profile Plot for Culvert: Culvert 1 860 866 -850 C _0 846 w 840 836 830 826 Crossing - Crossilig 1, Design Discharge - 918.7 efs CWvert - CWvert L. Cuh-ert Discharge - 918.7 cfs 0 0 20 40 60 8 Stati on (ft) Site Data - Culvert 1 Site Data Option: Culvert Invert Data Inlet Station: 0.00 ft Inlet Elevation: 826.50 ft Outlet Station: 66.00 ft Outlet Elevation: 826.00 ft Number of Barrels: 1 Culvert Data Summary - Culvert 1 Barrel Shape: Concrete Box Barrel Span: 9.00 ft Barrel Rise: 10.00 ft Barrel Material: Concrete Embedment: 12.00 in Barrel Manning's n: 0.0120 (top and sides) Manning's n: 0.0350 (bottom) Culvert Type: Straight Inlet Configuration: 1:1 Bevel Headwall Inlet Depression: None Table 3 - Downstream Channel Rating Curve (Crossing: Crossing 1) Flow (cfs) Water Surface Elev (ft) Depth (ft) Velocity (ft/s) Shear (psf) Froude Number 716.51 831.28 3.78 6.47 2.47 0.69 918.68 1 831.79 1 4.29 1 6.94 1 2.81 1 0.70 Tailwater Channel Data - Crossing 1 Tailwater Channel Option: Trapezoidal Channel Bottom Width: 18.00 ft Side Slope (H:V): 3.00 (_:1) Channel Slope: 0.0105 Channel Manning's n: 0.0450 Channel Invert Elevation: 827.50 ft Roadway Data for Crossing: Crossing 1 Roadway Profile Shape: Constant Roadway Elevation Crest Length: 50.00 ft Crest Elevation: 862.50 ft Roadway Surface: Paved Roadway Top Width: 40.00 ft HY-8 Energy Dissipation Report External Energy Dissipator Parameter Value Units Select Culvert and Flow Crossing Crossing 1 Culvert Culvert 1 Flow 716.51 cfs Culvert Data Culvert Width (including multiple barrels) 9.0 ft Culvert Height 10.0 ft Outlet Depth 5.81 ft Outlet Velocity 13.71 t/s Froude Number 1.00 Tailwater Depth 3.78 ft Tailwater Velocity 6.47 t/s Tailwater Slope (SO) 0.0076 External Dissipator Data External Dissipator Category Streambed Level Structures External Dissipator Type Riprap Basin Restrictions Froude Number <3 Input Data Condition to be used to Compute Basin Outlet Velocity Best Fit Curve D50 of the Riprap Mixture Note: Minimum HS/D50 = 2 is Obtained if D50 = 0.953 ft D50 of the Riprap Mixture 0.953 ft DMax of the Riprap Mixture 1.417 ft Results Brink Depth 5.809 ft Brink Velocity 13.705 t/s Depth (YE) 5.809 ft Riprap Thickness 2.126 ft Riprap Foreslope 2.8590 ft Check HS/D50 Note: OK if HS/D50 > 2.0 HS/D50 2.005 HS/D50 Check HS/D50 is OK Check D50/YE Note: OK if 0.1 < D50/YE < 0.7 Check D50/YE 0.164 D50/YE Check D50/YE is OK Basin Length (LB) 36.554 ft Basin Width 33.370 ft Apron Length 9.554 ft Pool Length 27.000 ft Pool Depth (HS) 1.911 ft TW/YE 0.650 Tailwater Depth (TW) 3.776 ft Average Velocity with TW 4.637 t/s Critical Depth (Yc) 12.314 Average Velocity with Yc 18.149 t/s 1r 01--1 UNITED IN OUR PURSUIT OF YOUR VISION, WE WILL LEVERAGE OUR KNOWLEDGE, OFFERINGS AND CULTURE TO CREArE MEANINGFUL EXPERIENCES. > Durham, NC Headquarters 2905 Meridian Parkway Durham, NC 27713 TI MCADAMS > Charlotte, NC 3430 Toringdon Way Suite 110 Charlotte, NC 28277 1. 800. 733. 5646 www.mcadamsco.com