Loading...
HomeMy WebLinkAboutWQ0007169_AROCompleteFile_20190208W. RONALD HAYNES, P. E. CONSULTING ENGINEER October 6, 2000 Stormwater And General Permits Units Division of Water Quality . 1617 Mail service Center Raleigh; NC 27699-1617 Subject: Caldwell Ready Mix, Inc. .Please find enclosed a Notice of Intent form for the above facility. Included are the check for the certificate of coverage fee and the location maps. Sincerely, .yG , oe-v,-..�Cd W. Ronald Haynes, P.E. _cc:, Michael Triplette im Reid NC DENR DWQ ARO U N LO N F— U 0 828 P.O. BOX 666 • GRANITE FALLS, NORTH CAROLINA 28630 a TEL. (p,%* 396.5978 State of North Cai Department of En and Natural Reso Division of Water Qu James B. Hunt, Jr., Bill Holman, Secret Kerr T. Stevens, Di '7 )lina ironment rces lity )vernor, for January 8, 2001 MR. MICHAEL L. TRIPLETT] CALDWELL READY MIX POST OFFICE BOX 461 GRANITE FALLS, NC 28630 Dear Mr. Triplette: j PRESIDENT Subject: / • • NCDENR. NORTH CAROLINA DEPARTMENT OF ENVIRONMENT,AND NATURAL RESOURCES f k� SAN If22001 !f ; E AmIJ Application No. WQ0007169 Additional Information Request Caldwell Ready Mix Recycle Facility Caldwell County The Non -Discharge Permitting Unit has conducted a preliminary engineering review of the subject application. Additional information is required before we can continue our review. Please address the following by February 15, 2001: ♦ Please provide more detailed information on the settling basin operation. Please include specific detail on the overflow process of the settling basin. ♦ Please provide information on the overflow drain located on the west side of the building beside the settling basin. Please clarify the source of the flow for this drain. Please note that additional comments from the Regional Office are pending at this time, and further requests may be necessary to address these comments. Please be aware` -that you are responsible for meeting; all requirements set forth in North Carolina rules and regulations. Any oversights that occurred in the review of the subject application package are still the responsibility of the applicant. In addition, any omissions made in responding to the above items may result in future requests for additional information. Please reference the 'subject permit application number when providing the requested information. Two (2) copies of the requested information should be signed, dated, and submitted to my attention at the address below. Please note .that failure to provide this additional information on or before the above requested date can result in your application being returned as incomplete. 1617 Mail Service Center, Raleigh North Carolina 27699-1617 Telephone 919-733-5083 FAX 919-733-0719 An Equal Opportunity !,Affirmative Action Employer 50% recycled/ 10% post -consumer paper I If you have any questions regarding this request, please call me at (919) 733-5083, extension 370. Thank you for your cooperation. Sincerely, _--- 1 - Sharnay E. Torrance Environmental Engineer. Non -Discharge Permitting Unit Cc: Jim Reid, Ashville Regional Office, Water Quality Permit File WQ0007169 ,+ Division of Fater Quality / Fater Quality Section NCDENRNational Pollutant Discharge Elimination System NOW" CAROUM DMVRWEWO Ewnwyor AND NAtisw. ftwup= NCG140000 to NOTICE OF INTENT National Pollutant Discharge Elimination System application for coverage under General Permit NCG140000- STORMWATER AND PROCESS WASTEWATER DISCHARGES associated with activities classified as: SIC` 3273 Ready Mixed Concrete ' Standard Industrial Classification Code i (Please print or type) 1) Mailing address' of owner/operator:. Name Caldwell Ready Mix, Inc. Street Address P O . Box 461 City Granite Falls State Nom_ ZIP Code 28630 Telephone No. 828 396-21 37 Fax:. 828 396-6141 ' Address to which all permit correspondence will be mailed 2) Location of facility producing discharge: Facility Name Caldwell Ready Mix, Facility Contact Michael L. Triplette Street Address 2823 Mission Road City Hudson County Caldwell Telephone No.. 828 396-2137 Fax: 828 396-6141 3) Physical Location Information: Please provide a narrative description of how to get to the facility (use street names, state road numbers, and distance and direction from a roadway intersection), from Lenoir, NC --take Hwy 321- south to SR 1108, turn right (west) Plant entrance on left about 300 yds (A copy of a county map or USGS quad sheet with facility clearly located on the map Is required to be submitted with this application) 4) This NPDES Permit Application applies to which, of the following ❑ New or Proposed Facility Date operation is to begin December 2000 P Existing 5) Standard Industrial Classification: Provide the 4 digit Standard Industrial Classification Code (SIC Code) that describes the primary industrial activity atthis_facility SIC Code:3 ; 2 7 3 6) Provide a brief description of the types of industrial activities and products produced at this facility (Include a site processldiagram with this submittal): Facility stores raw materials and. manufactures concrete batches for trans t in trarja.L x tsps Inc. State NC ZIP Code 28638 Page 1 of 4 SWU-229-080199 NCG140000 N.O.I. 7) Discharge points / Receiving waters: How many discharge points (ditches, pipes, channels, etc.) convey stormwater from the property? 3 What is the name of the body or bodies of water {creek, stream, river, lake, etc.) that the facility stormwater discharges end up in? Little Gunpowder Creek If the site stormwater discharges to a separate storm sewer system, name the operator of the .separate storm sewer system (e.g. City' of Raleigh municipal storm sewer . Receiving water classification (if known): "Y`' WS— Note: Discharge of process wastewater to receiving waters classified as WS -II to WS -V or SA must be approved by the N.C. Dept. of Environmental Health. If DEH does not approve, coverage under NCG140000 cannot be granted. No new discharges of process wastewater are permitted in receiving waters classified as WS -1 or freshwater. ORW 8) Does this facility have any other NPDES permits? - 1?5 No ❑ Yes If yes, list the permit numbers for all current NPDES permits for this facility: 9) Does this facility have any Non -Discharge permits (ex: recycle permits)? ❑ No 13 Yes If yes, list the permit numbers for all current Non -Discharge permits for this facility: WQ 0 0 071 6 9 10) Does this facility employ any best management practices for stormwater control? ❑ No 9 Yes If yes, please briefly describe:... Administrative measures include debris control and site will have a retention basin 11) Does this facility have a Stormwater Pollution Prevention Plan? 13 No ❑Yes' If yes, when was it implemented? 12) Are vehicle maintenance activities occurring at this facility? ❑ No 5 Yes 13) .Are discharges occurring from any of the following process wastewater generating activities? Vehicle and equipment cleaning ❑ Yes IN No Wetting of raw material stockpiles ❑ Yes M No Mixing drum cleaning ❑ Yes IN No If yes to any of the above, please describe the type of process used to treat and/or recycle the process t wastewater. Give design specifics (i.e. design volume, retention time, surface area, etc.). [Use separate sheet(s)] Note: Construction of any wastewater treatment facilities require submission of three (3) sets of plans and specifications along with this application. Design of treatment facilities must comply with requirements 15A NCAC 2H,.0138. SWPage U-229-080199 1 2 of 4 j NCG140000 N.O.I. 14) Does the facility use a recycle system? ❑ No IR Yes If yes, does the system overflow only during rainfall events exceeding the 10 -yr, 24 -hr rainfall event? ❑ Yes IR No If yes, provide plans, calculations, and supporting documentation. 15) Hazardous Waste: a) Is this facility a Hazardous Waste Treatment, Storage, or Disposal Facility? M No ❑ Yes b) Is this facility a Small Quantity Generator (less than 1000 kg. of hazardous waste generated per calendar year) of hazardous waste? M No ❑ Yes c) Is this facility a Large Quantity Generator (1000 kg. or more of hazardous waste generated per calendar year) of hazardous waste? IR No ❑ Yes d) . If you answered yes to questions b. or c., please provide the following information: Type(s) of waste: How is material stored: Where is material stored: How many disposal shipments per year: Name of transport / disposal vendor: Vendor address: 16) Certification: North Carolina General Statute 143-215.6 b (i) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan or other document filed or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with or knowingly renders inaccurate any recording or monitoring device.or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $10,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides . a punishment by a fine of not more than $10,000 or Imprisonment not more than 5 years, or both, for a similar offense.) I hereby request coverage under the referenced General Permit. I understand that coverage under this permit _ will constitute the permit requirements for the discharge(s) and is enforceable in the same manner as an individual permit. I certify that I am familia , with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed Name of Person Signing:. Michael L. Triplette Title: ! President (Signature "of Page 3 of 4 SWU-229-080199 - '�'', a -o (Date Signed) NCG 140000 N.O.I. Notice of Intent must be accompanied by a check or money order for $80.00 made payable to: i NCDENR Final Checklist This application will be returned as incomplete unless all of the following items have been included: ❑ Check for $80 made payable to NCDENR ❑ This completed application and all supporting documention ❑ Copy of county map or USGS quad sheet with location of facility clearly marked on map Mail the entire package to: Stormwater and General Permits Unit Division of Water Quality 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Note The submission of this document does not guarantee the issuance of an NPDES permit. Page 4 of 4 SWU-229-080199 :READ-'-IVV�'lX� ECLAMA.TION��SYSTEMS L EA D IN G...-,-T\H EN D,U-.,S TR -+Y ` NN --ENVIRONMENTAL PER'F'RMANCE 1 ,' t o _ + � `" a �'```• � '- ,}�t �M. e � i F W W X X w w A- M/X. RECLAMATION f 100% Recycle of Aggregates and Slurry ♦ Minimum Fresh Water Usage ♦ Ability to Handle Fiber • Above Ground Construction • High Quality Components ♦ Simplicity in Design and Operation ♦ Fully Automatic Control for Self -Cleaning SYSTEMS 1-800• ti The EwRO-POO RT 1. Returned ready -mix is poured directly into the Recycling. Sys.term intake hopper. Sand and stone is swept into the cess is performed diagonal screw conveyor while slurry is kept in suspension in the agitation tank. he following steps.. 2. Clean sand and stone is transported above slurry level where it is given a final rinse and stock piled for reuse. (Separation can be performed with optional screen deck.) i f1� 3. Slurry water is metered back to the batch plant i for reuse by way of a weigh batch system or a I� magnetic flowmeter. Specific gravity can also be monitored with optional suspended solids monitor. 4. A storm water and/or process water capture milli� basin can be added to your plant. This water can be automatically pumped into your ENVIRO-PORT system for reuse in batching. The ENVIRO-PORT system can "use up" this i� water instead of creating more. t 77 —0 AO - 4 y , l �- �Ij i:,:�.•l � J ...,�, �.9" n3 �'. _.,,_-_--,.` .:, . .. yam. _ 1 . 1 s `. r 0 ri z F 8.1.06 Main Electrical Panel with ENVIRO-PORT is a complete, above ground system that Programmable Logic is easy to transport or relocate. Controller for Automatic Equipment Operation. With the ENVIRO-PORT Ready Mix Reclamation System, you will be able to reclaim 100% of your unpoured concrete, eliminate settling ponds, recover valuable yard space, clean up your ground water, and increase your profits. ENVIRO-PORT's patented process and automatic safety features will put you in the driver's seat. Each system is a compact, self-contained unit — pre -wired, pre -plumbed, easy to transport, easy to relocate, easy to service, and easy to expand. Whatever the size of your fleet, we can build the system that is right for you. For more information, call 1-800-356-8106 today. Call 1-800-356-8106 for more information Member of: ENVIRO-PORT5 INC. 10953 Dunbarton Road P.O. Box 175 - Gratiot, WI 53541 1-800-356-8106 - 1-608-922-6264 FAX 1-608-922-3370 WON coNm`yRfADYMfXfO IONI�EIE 11 1 ASSO�i4M ENVIRO-PORT5 INC. 10953 Dunbarton Road P.O. Box 175 - Gratiot, WI 53541 1-800-356-8106 - 1-608-922-6264 FAX 1-608-922-3370 Specifications for Process Water Recycle Facility Caldwell Ready Mix, Inc. 2823 Mission Road Saw Mills, North Carolina Trigon Project # 045-00-025 October 2000 SPECIFICATIONS FOR PROCESS WATER RECYCLE FACILITY WASHOUT RECOVERY SYSTEM REVISION 2 CALDWELL READY MIX, INC. SAW MILLS, N. C. By: Trigon Engineering Consultants, Inc. Charlotte, N.C. October 6, 2000 04500025 SUL 74 53 8��ao YO NA .a• 01010 SUMMARY OF WORK Part I. General 1.1 Scope of Work This specification covers the work necessary to install a washout water recovery system for the Caldwell Ready Mix, Inc. concrete batch mixing plant. The existing sedimentation/seepage basin will be removed from operation. 1.2 System Description This system is designed to treat wastewater generated from cleaning concrete batch truck mixing drums and from washing the exterior of the batch trucks. It also receives stormwater from the process area. Return unused mix is discharged directly to an 8 ft DIA slurry tank. The drum interior is deluged and the contents are also expelled directly into the reclaim system. The sand and gravel in the return mix and washout water settle and move out from the center of the slurry tank propelled by the cyclonic flow induced by the tank agitator. At the perimeter, the sand and gravel are swept into a screw conveyor and carried up and out of the tank. The sand and gravel are washed in the conveyor to remove fines and discharged onto a screen deck where they are mechanical screened into individual stockpiles. The slurry is transferred to the 12 ft DIA agitation tank where the remaining solids are held in suspension. The slurry is periodically returned to the batch mix process for recycle to the product. The wastewater originating from cleaning the batch truck exterior discharges onto a concrete slab sloped to a shallow settling basin. Most of the solids settle in the basin, which is sloped to allow removal of the sediment with a front-end loader. The water from the basin is pumped back to the batch mixer for process use. A portion of the reclaimed water is used in the batch truck makeup tank for use in adjusting the mix off site. All stormwater from the truck washing and the process operations areas will be directed to the settling basin. During 'storm events of greater than approximately 0.50 inches the basin will overflow to an outfall on the west side of the plant. Stormwater from two other areas are not routed through the recycle system. Flow from the parking area and run-on from offsite will be directed to the east outfall. The roof drainage from the garage will be directed to a third outfall. 1.3 Project Description The project shall consist of backfilling the existing sedimentation lagoon and removing the stock pile, site grading, construction of slabs and the new sedimentation basin, installation of mechanical equipment, and site drainage grading for diversion of surface run-off. Page 1 of 5 1.4 Regulatory Requirements All work, materials, supplies, and equipment shall be in compliance with local, state and applicable federal codes and regulations. Final installation shall not commence until all necessary permits and approvals have been obtained. 1.5 Erosion Control An Erosion/Sedimentation Control Plan will not be required for the project. However, prior to construction, proper protection of the nearby stream shall be obtained by installing protective measures to prevent excessive siltation from impacting the stream. These protection measures will be maintained throughout the construction process. Any temporary sedimentation basins constructed during the construction phase shall be maintained in a manner to prevent sediment from flowing into the stream. Protection features will be removed at the completion of construction as necessary by removal and disposal of siltatious materials. All denuded areas shall be properly grassed and mulched as soon as practicable. Part II. Products 2.1 Concrete All concrete shall have a minimum of 3,000 psi compressive strength and a slump of 5 inches or less. 2.2 Equipment All equipment, pumps, conveyors, hoppers, etc. shall be consistent with the requirements of the project. The mechanical equipment shall be as manufactured by Enviro-Port, Inc., Gratiot, Wisconsin or equal. Alll mechanical equipment including pumps, shall be provided by the Owner and installed by the contractors. 2.3 Reinforcing Steel All reinforcing steel shall be intermediate grade billet steel, deformed. bar stock, clean and free of rust and corrosion. 2.4 Backfill Materials Exterior walls of the recycle facility shall be backfilled with clean, well compacted soil and/or with flowable backfill material' as manufactured by the on site concrete batch plant. Page 2 of 5 2.5 Piping All wastewater piping will be Scheduled 40 PVC pipe and made from Type 1 Polyvinyl Chloride. Service temperatures do not exceed 140 degrees F. Pipe shall conform to the requirements of ASTM D-1785. All socket type connections will be joined with primer and solvent cement complying to ASTM D-2564. 2.6 Valves & Fittings All wastewater piping valves will be true union ball valves made from PVC Type 1 Grade 1 molding compound. All fittings shall conform to ASTM D-2467 for socket type and ASTM D- 2464 for threaded type. Part III. Execution 3.1 Definitions Owner - Caldwell Ready Mix, Inc. Michael Triplette, President Engineer - Trigon Engineering Consultants, Charlotte, N.C. Contractor - Parties providing equipment, materials, supplies and/or installation of the same. Vendor - Any firm and/or party supplying materials or equipment only. 3.2 Construction Management All work will be performed under contracts, purchase orders, and/or agreements administered by the Owner. Construction, installation of equipment and start-up procedures shall be supervised and inspected by the Engineer and any other regulatory authority as required. 3.3 Site Work The existing sedimentation basin and, concrete spoil pile will be removed to allow installation of the new system. The existing sedimentation basin will be filled to design grade. 3.2 Construction Management All work will be performed under contracts, purchase orders, and/or agreements administered by the Owner. Construction, installation of equipment and start-up procedures shall be supervised and inspected by the Engineer and any other regulatory authority as required. Page 3 of 5 3.3 Site Work The existing sedimentation basin and concrete spoil pile will be removed to allow installation of the new system. The existing sedimentation basin will be filled to design grade. 3.4 Footings All footings shall be poured in level trenches cut into natural soil or flowable backfill. Footings shall contain #4 bars @ 8"o.c. continuous for length of footing trench. 3.5 Slabs All slabs shall be poured on soil compacted to 95% standard proctor or cured flowable backfill. Slabs shall be reinforced with #4 bars @ 12"o.c. both ways. 3.6 Walls All containment walls shall be poured in concrete, 12" thick to the height indicated on plans. All walls shall have #4 reinforcing bars @ 12"o.c. each way. Wall pours shall be continuous until forms are filled with nolcold joints. All walls shall be keyed to the floor slabs and to the footings. 3.7 Mechanical Equipment The mechanical system will be shipped assembled. Installation will include locating and setting the system, providing water supply and connection to return flow recycle water, and electrical wiring. The system shall be installed in conformance with the manufacturer's instructions. 3.8 Piping 3.8.1 Aboveground Piping Piping shall be installed in a neat manner with lines straight and parallel or at right angles and as shown on the drawings. Run piping so as to avoid interference with other lines and systems. All work shall be accomplished using the best methods and procedures of recognized pipe fabrication in a workmanlike manner in accordance with the latest revision of applicable ANSI Standards, ASME Codes and PPI Standards. Pipe shall be cut square, not upset, undersized, or out of round. Ends shall be carefully reamed and cleaned before being installed. Use fittings for all changes in direction. Pipe supports shall be selected as required to support the weight of the pipe, fittings, valves, weight of medium transported and weight of insulation covering used. Solvent welded fittings adequate to withstand 50 psig shall be used at all times for PVC pipe. Page 4 of 5 3.8.2 Underground Piping Underground piping shall be laid at a minimum of 18 inches below the ground surface. The trench shall be excavated to provide a firm continuous and a minimum of 4 inches of fine grained sand shall be placed to cushion the trench bottom. The pipe shall be covered by sand a minimum of 2 inches before placing additional backfill. Pressure testing of the underground piping shall be completed after backfilling and prior to any concrete being placed. Installation of the underground piping shall also follow the piping manufacturers recommendations. 3.8.3 Encapsulated Piping Aboveground piping installed within the concrete forms and covered by the concrete shall be installed as in Section 3.8.1 with supports adequate to hold the piping in place during the pour. The piping shall be located so that the structural strength of the concrete walls is not significantly impaired. Page 5 of 5 CALCULATIONS CALDWELL READY MIX Annual Production 1999 24,000 cu yd Assum;e 200 day/yr active production Assume 500 hr/yr active production Production Capacity 200 cu yd/day Production Utilization 48 cu yd/hr Maximum Average 120 cu yd/day Truck Movements 13.33 events at 9 cu yd per truck Truck Wash Water 5,333 gpd assume 300 gal per truck internal Generated 100 gal per truck external 400 gal per truck total Truck Wash Water 1333 gpd Generated -External Concrete Mix Water 4,200 gpd assume 35 gal/cu yd water in mix Required Note: All water used in truck washing is processed in the treatment system and return for use in the mix or reused as wash water. Only exterior wash water is routed through the settling basin. Flow to Settling Basin Assume truck cleaning takes 2 hrs/day Avg flow to clarification basin is 11.1 gpm with no stormwater Settling Basin Area 800 sq ft Overflow rate 0.014 gpm/sq ft OK <2 gpm/sq ft Overflow rate (daily) 1.667 gpd/sq ft OK <600 gpd/sq ft Note: During storm events the rainwater will contribute to the flow to the settling basin. See following calculations. Production will likely be curtailed during extreme storm events. Overflow of the basin will occurr during rain events greater than about 0.5 inches. CRM-RSYS.XLS 1 CALDWELL READY MIX Stormwater Contribution to settling basin Area of Drainage 40000 sq ft Annual Volume 872,667 gal Avg Storm Volume 12,467 gal Basin volume is 14,500 gal 100% paved - assume coefficient is 1.0 for paved area Assume 35 in/yr rainfall Assume 0.5 in/day rainfall Note: Depending on initial volume present the basin should retain a 0.5 inch rain event. Peak Volume 149,600 gal Assume 6 in/day rainfall Overflow Rates Settling Basin Width 20 ft Settling Basin Length 40 ft Settling Basin Area 800 sq ft Overflow w/no rain 1.7 gal/day/sq ft Overflow w/ peak volume 187.0 gal/day/sq ft CRM-RSYS.XLS 2 OK<600 gpd/sq ft OK<600 gpd/sq ft Makeup Water ....... o, Truck Wash External Truck Washout Concrete Batch Active Process and -qq- Interior �- -� Plant No Stock files 4,200 gpd leaves -site - 1,333 gpd- 5,333 gpd in batch trucks Settling Basin 14,500 gal Enviro-Port Recycle System F -A Basis: 120 cu. yd/day concrete production Note: 4,200 gpd makeup water ' required from on site well or from stormwater flows Makeup Water CALDWELL READY MIX, INC. WASHOUT RECOVERY SYSTEM PROCESS FLOW DIAGRAM 10/6/00 wrh CALDWELL READY MIX Annual Production 1999 24,000 cu yd Assum;e 200 day/yr active production Assume 500 hr/yr active production Production Capacity 200 cu yd/day Maximum Truck Movements 22.22 events at Truck Wash Water 8,889 gpd assume Generated Truck Wash Water 2222 gpd Generated -External Production Utilization 48 cu yd/hr Maximum 200 cu yd/day 9 cu yd per truck 300 gal per truck internal 100 gal per truck external 400 gal per truck total Concrete Mix Water 7,000 gpd assume 35 gal/cu yd water in mix Required Note: All water used in truck washing is processed in the treatment system and return for use in the mix or reused as wash water. Only,exterior wash water is routed through the settling basin. Flow to Settling Basin Assume truck cleaning takes 2 hrs/day Avg flow to clarification basin is 18.5 gpm with no stormwater Settling Basin Area 800 sq ft Overflow rate 0.023 gpm/sq ft OK <2 gpm/sq ft Overflow rate (daily) 2.778 gpd/sq ft OK <600 gpd/sq ft Note: During storm events the rainwater will contribute to the flow to the settling basin. See following calculations. Production will likely be curtailed during extreme storm events. Overflow of the basin will occurr during rain events greater than about 0.5 inches. CRM_MAX.XLS 1 CALDWELL READY MIX Stormwater Contribution to settling basin Area of Drainage 40000 sq ft Annual Volume 872,667 gal Avg Storm Volume 12,467 gal Basin volume is 14,500 gal 100% paved - assume coefficient is 1.0 for paved area Assume 35 in/yr rainfall Assume 0.5 in/day rainfall Note: Depending on initial volume present the basin should retain a 0.5 inch rain event. Peak Volume .149,600 gal Assume 6 in/day rainfall Overflow Rates Settling Basin Width 20 ft Settling Basin Length 40 ft Settling Basin Area 800 sq ft Overflow w/no rain 2.8 gal/day/sq ft Overflow w/ peak volume 187.0 gal/day/sq ft CRM_MAX.XLS 2 OK<600 gpd/sq ft OK<600 gpd/sq ft Makeup Water ...... ._, Truck Wash External Active Process and , 2,222 gpd Settling Basin 14,500 gal Basis: 200 cu yd/day concrete production Note: 7,000 gpd makeup water required from on site well or from stormwater flows Truck Washout Interior 8,889 gpd Enviro-Port Recycle System CALDWELL READY MIX, INC. WASHOUT RECOVERY SYSTEM PROCESS FLOW DIAGRAM Concrete Batch Plant Makeup Water 7,000 gpd leaves site in batch trucks 10/6/00 wrh MANUFACTURER'S LITERATURE TM ENVIROMPORTx Ready -Mix Reclamation ;Systems ENVIRO-PORT SYSTEM 14-2250 Basic Unit - 2,250 gallon capacity with processor control. Concrete Processing Rate:10Yds. per hour. SLURRY TANK CONSTRUCTION: Tank Walls 1/4" A-36 plate, Tank Floor 1/2" A-36 plate. Agitator Drive 10 IIP input, 8382 NORD Direct Drive Speed Reducer. SCREW CONVEYOR CONSTRUCTION: Outer Tube 14" O.D. x 3/8" Wall, Flighting 13" x 22° x 3/8" A.R. 400 Flighting, Drive Unit 10 HP input, BROWNING 215 Speed Reducer. SLURRY PUMP: 71/2 HP 1150 R.P.M. input, DEMING 3M, 10" Impeller with fresh water seal flush. SHIPPING WEIGHT:15,000 lbs. ENVIRO-PORT SYSTEM 24-2250 Basic Unit - 2,250 gallon capacity, with processor control. Concrete Processing Rate: 30+ Yds. per hour. SLURRY TANK CONSTRUCTION: Tank Walls 1/4" A-36 plate, Tank Floor 1/2" A-36 plate. Agitator Drive 10 HP input, 8382 NORD Direct Drive Speed Reducer. SCREW CONVEYOR CONSTRUCTION: Outer Tube 27" x 27" x 1/4" Wall, Flighting 23" x 22" x 1/2" A.R. 400 Flighting, Drive Unit 15 HP input, BROWNING 315 Speed Reducer. SLURRY PUMP:7 1/2 HP 1150 R.P.M. input, DEMING 3M, 10" Impeller with fresh water seal flush. SHIPPING WEIGHT: 18,800 lbs. ENVIRO-PORT 2,250 GALLON AGITATION TANK 8' Diameter x 6' High. SLURRY TANK CONSTRUCTION: Tank Wall 1/4" A-36 plate,Tank Floor 1/2" A-36 plate, 5 HP Drive Unit. SHIPPING WEIGHT: 8,500lbs. ENVIRO-PORT 5,500 GALLON AGIIAATION TANK 12' Diameter x 7' High. SLURRY TANK CONSTRUCTION: Tank Wall 1/4" A-36 plate,Tank Floor 1/2" A-36 plate, Drive Unit 7 1/2 HP input, 8382 NORD Direct Drive Speed Reducer. SHIPPING WEIGHT: 14,000 lbs. ENVIRO-PORT 6,900 GALLON AGITATION TANK 13' Diameter x 7' High. SLURRY TANK CONSTRUCTION: Tank Wall 1/4" A-36 plate,Tank Floor 1/2" A-36 plate, Drive Unit 7 1/2 HP input, 8382 NORD Direct Drive Speed Reducer. SHIPPING WEIGHT: 14,800 lbs. 10953 Dunbarton Road, P.O. Box 175, Gratiot, W1 53541 Phone: 800-356-8106 • 608-922-6264 • FAX` 608-922-3370 28'10* 5,500 GAL. AGITATION TANK j 000 0 000 000 0 000 0000000 000 0 000 000 0 000 000 0 000 < 10, > X12' OPTIONS Flush Boom System For Slurry Washout — Each boom complete with all necessary plumbing, including a 2" actuator ball valve and an on/off switch. 3" Maglite Magnetic Flowmeter — For pulse output.To control slurry pumping to batch plant. ABCO 36" x 72" Single Deck Vibrating Screen — For use with 14" auger system. ABCO 48" x 96" Single Deck Vibrating Screen — For use with 24" auger system. Automatic Back -Flushing of Slurry Line — All valves and controls to back- flush slurry line, including timers and relay box. Mass Flowmeter — With Datamate 2000 programmable keypad, for display of slurry density, solids rate, mass rate, temperature, total, volume, and flow counts. (Overall Width = 12'4") I 3-7- 7-6- (Overall '7"7'6" Factory Installed, Replaceable Kryptane Flighting Tips — For 24" auger system. Factory Installed, Replaceable A.R. 400 Flighting Tips — For 24" auger system. 12' Wide Discharge Splash Panel — In place of a 8' wide panel. Suggested for a 2 truck discharge. 17' Wide Discharge Splash Panel — In place of a 12' wide panel. Suspended Solids Monitor —To read the amount of solids in slurry being pumped to Batch Plant. Factory Installed Automatic Grease System — For Positive Lubrication. TM ENVIROmPORTu- Ready-Mix Reclamation Systems ♦ 100% Recycle of Aggregates and Slurry ♦ Minimum Fresh Water Usage ♦ Ability to Handle Fiber ♦ Above Ground Construction and Transportable ♦ High Quality Components ♦ Simplicity in Design and Operation 2. Clean sand and stone is removed from I mix and stock piled for reuse. Sand and stone can also be separated with optional ,, 'screen deck. 4. Your plant storm water and Z process water can also be metered and reused by the Enviro-Port System (It can "use up" this water instead 3. Slurry water is of creating more!). metered back to the batch plant for reuse. 6,17111-SDO-.3S6-$/06 formore informotion ppy/T/Vj! F54LUT�04/s to mixer truck woshout ondconcre to rec%imPro6/ems I. Returned concrete is poured into the Enviro-Port intake hopper. U n ENVIRO-PORT, INC. P.O. Box 175 - Gratiot,W1 5354 1-800-356-8106 1-608-922-6264 FAX 1-608-922-3370 State of North Carolin Department of Environment, Health and Natural Resources - Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director December 8, 1993 Mr. Michael L. Triplett, President Caldwell Ready Mix, Incorporated Post Office Box 461 Granite Falls, Nortli-Carolina 28630 Dear Mr. Triplett: ®[=-HNF1 Subject: Permit No. WQ0007169 Caldwell Ready Mix, Inc. Washout Recovery System Wastewater Recycle System Caldwell County In accordance with your application received October 26, 1992, we are forwarding herewith Permit No. WQ0007169, dated December. 8, 1993, to Caldwell Ready Mix, Incorporated for the subject wastewater recycle system. This permit shall be effective from the date of issuance until November 30, 1998, and.shall be subject to the conditions and limitations as specified therein. Please` pay particular attention to the monitoring requirements in this permit. Failure to establish an adequate system for collecting and maintaining the required operational information will result in future compliance problems. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North.. Carolina General Statutes; and filed with the Office of Administrative Hearings, P.O. Drawer_ 27447; Raleigh, NC 27611-7447. Unless such demands are made this permit shall be final and binding: ; One set of approved plans and specifications is being forwarded to you. If you need additional information concerning this matter, please contact Ms. Angela Y. Griffin at 919/ 733-5083. Sincerely, n �� A. Pres o Howard, Jr., P.E. cc: Caldwell County Health Department �►A�sheille+'_R-egio 11®ffice;W,�ater-Quality7Seetion� t5 Haynes Engineering Associates Training and Certification Unit DEG 1 1993 Facilities Assessment Unit P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 MAX912` n An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post=consumer paper NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT, OF ENVIRONMENT, HEALTH AND NATURAL RESOURCES RALEIGH RECYCLE SYSTEM PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Caldwell Ready Mix, Incorporated Caldwell County . FOR THE construction and operation of a 4,000 GPD wastewater recycle system -consisting of a truck wash out pad, a hopper for separating aggregates, mechanical screw screening conveyors, stockpile slabs, primary separation slab, three (3) clarification basins ( approximately 9,090 gallons, 8,525 gallons and 22,740 gallons), and all necessary pumps, valves and appurtenances to serve Caldwell Ready Mix, Incorporated's truck washing and concrete operation with no discharge of wastes to the surface waters, pursuant to the application received October 26, 1992 and in conformity with the project plan, specifications, and other supporting data subsequently filed and approved by the Department of Environment, Health and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until November 30, 1998, and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans, specifications, and other supporting data. 2. This permit is effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The facilities shall be properly maintained and operated at all times. 4. This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the. Permittee, a formal permit request must be submitted to the Division of Environmental Management accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of the request -will be considered on its merits and may or may not be approved. 5. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications. Mail the Certification to the Permits and Engineering Unit, P.O. Box 29535, Raleigh, NC 27626-0535. 6. In the event Arai Lhe facilities fail to perform satisfy_ !'. ly, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement wastewater treatment or disposal facilities. 7. The Asheville Regional Office, telephone number (704) 251-6208, shall be notified at least forty-eight (48) hours in advance of operation of the installed facilities so that an in-place inspection can be made. Such notification to the regional supervisor shall be made during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. 8. The sludge generated from these treatment facilities must be disposed of in accordance with General Statute 143-215.1 and in a manner approved by the North Carolina Division of Environmental Management. 9. The issuance of this permit shall not relieve the Permittee of the responsibility for damages to surface or groundwaters resulting from the operation of this facility. 10. The facilities shall be effectively maintained and operated as a non -discharge system to prevent the discharge of any wastewater resulting from the operation of this facility. 11. Diversion or bypassing of untreated wastewater from the treatment facilities is prohibited. 12. Any monitoring deemed necessary by the Division of Environmental Management to insure surface and ground water protection will be established and an acceptable sampling reporting schedule shall be followed. 13. Adequate inspection, maintenance, and cleaning shall be provided by the Permittee to insure proper operation of the subject facilities. 14. The Permittee or his designee shall inspect the wastewater recycle facilities to prevent malfunctions and deterioration, operator errors and discharges which may cause or lead to the release of wastes to the environment, a threat to human health, or a nuisance. The Permittee shall keep an inspection log or summary including at least the date and time of inspection, observations made, and any maintenance, repairs, or corrective actions taken by the Permittee. This log of inspections shall be maintained by the Permittee for a period of three years from the date of the inspection and shall be made available upon request to the Division. of Environmental Management or other permitting authority. 15. Any duly authorized officer, employee, or representative of the Division of Environmental Management may, upon presentation of credentials, enter and inspect any property, premises or place on or related to the recycle system at any reasonable time for the purpose of determining compliance with this permit; may inspect or copy any records that must be kept under the terms and conditions of this permit; or may obtain samples of groundwater, surface water, or leachate. 16. The annual administering and compliance fee must be paid by the Permittee within thirty (30) days after being billed by the Division. Failure to pay the fee accordingly may cause the Division to initiate action to revoke this permit as specified by.15 NCAC 2H .0205 (c)(4) 17. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to an enforcement action by the Division of Environmental Management in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. 19. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other goverment agencies (local, state, and federal) which have jurisdiction. 2 18. A set of approplans and specifications for the subj&roject must be retained by the Permittee for the life of this project. 19. Noncompliance Notification: The Permittee shall report by telephone to the Asheville Regional Office, telephone number (704) 251-6208, as soon as possible, but in no case more than 24 hours or on the next working day following the occurrence or first knowledge of the occurrence of any of the following: a. Any occurrence at the wastewater treatment facility which results in the treatment of significant amounts of wastes which are abnormal in quantity or characteristic, such as the dumping of the contents of a basin or tank; the known passage of a slug of hazardous substance through the facility; or any other unusual circumstances. b. Any process unit failure, due to known or unknown reasons, that render the facility incapable of adequate wastewater treatment such as mechanical or electrical failures of pumps, aerators, compressors, etc. c. Any failure of a pumping station, sewer line, or treatment facility resulting in a by- pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. d. Any time that self-monitoring information indicates that the facility is not in compliance with its permit limitations. Persons reporting such occurrences by telephone shall also file a written report in letter form within 15 days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. 20. Upon classification of the facility by the Certification Commission, the Permittee shall employ a certified wastewater treatment plant operator to be in responsible charge (ORC) of the wastewater treatment facilities. The operator must hold a certificate of the type and grade at least equivalent to or greater than the classification assigned to the wastewater treatment facilities by the Certification Commission. The Permittee must also employ a certified back-up operator of the appropriate type and grade to comply with the conditions of Title 15A, Chapter 8A, .0202. The ORC of the facility must visit each Class I facility at least weekly and each Class II, III, and IV facility at least daily, excluding weekends and holidays, and must properly manage and document daily operation and maintenance of the facility and must comply with all other conditions of Title 15A, Chapter 8A, .0202. Once the facility is classified, the Permittee must submit a letter to the Certification Commission which designates the operator in responsible charge within thirty days after the wastewater treatment facilities are 50% complete. 3 21. The .permittee east six 6 months prior to the ex ira hof this permit, shall request its C) P P extension. Upon receipt of the request, the Commission will review the adequacy of the facilities described therein, and if warranted, will extend the permit for such period of time and under such conditions and limitations as it may deem appropriate. 'ermit issued this the 8th day of December, 1993- NORTH 993 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT.COMMISSION A. Preston oward, Jr., $.E., Director / Q Division of -Environmental Management By Authority of the Environmental Management Commission Permit No. WQ0007169 0 ermit No. WQ0007169 december 8, 1993 3ngineer's Certification as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the )roject, for the Project Name Location Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. Signature Registration No. Date 5 Hudson. f f �. .__. _ .-..��'��;, �;��/i x..� -hest�?.u� l,"', (:;•; <c .:_�•' . - � i •l%� '!i_�Dra �,5r�,;J.:' /'i ,i ti_.- _ -Yip=:: iii ,%j .. _ :.. ���,� i `;� 1 •; ' 'I i" � +�.' �;�•��• ��! �% .' J� ;�/i� (:�`�'- �T CLL-i�_� �_ ,�+•`� , � �f- � .` .�, :.7 ����7. '�-�� .i•• r( S, "I`�,`1'.�\\"'�i.'� ` `�l`,1 '�� ,_� � � .`� ■ ,�Il'•. . -'� �> 218 9•J �IgSG , 300 i NJ ---) 240 Pll \\ '� n� 1! 11 �' •"`171 • / `\ / '� \ `i1 1 \\ r/ � �1'I • IIIIfV✓/_'.1 •Fl It 't Reg l2 I200 • O oo i 700 11 High - ♦ 1, / � '� err � r 4 � r •,'�, 1 �``\ �� � '' �� �� _ `� / /T\� i� •`'�• $ " �r"� •� \� ��`�• C/�L.vWELL �ZEl�1�il �21,�' ' 0012 urs c J ' ter Gr9Q n = 1,0 ' � -�—/-lll .•u. 1 / \% lam. (• II �.• \moi \ n • r� ( U Mtl'Lion cii' .� \ ���--�'.c. °� /200 '\l C i,l� .� •: • . �\� ✓v� II �I 1�4 ° rl\1 G•/• j 11 1161 AN It �---`� �:: '.'fit• ;-� � �: 1 1`�i( �' /. ,���� •.�.. ill ( !/+�•. �i • —, 'i°'\� - . �( l-❑ - ,l �J�\� 1 r I 1 I (i c `rir % ���•'.�.: ' '\O • •/ �c_ Ji I- - - .�1 �,,'.v \. �� /�� _ i-, -- f,.,__ I +i i .r�..' 1 JldLU UI INUI U I vaIvill I" Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Bill Holman, Secretary Kerr T. Stevens, Director 1 � • NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES 3/20/2000 CERTIFIED MAIL RETURN RECEIPT REQUESTED MICHAEL L. TRIPPLET �1%1 CALDWELL READY MIX, INC-WASHO PO BOX 461 GRANITE FALLS NC 28630 k-�: ;'' MAR 2 3 2000 SUBJECT: NOTICE OF VIOLATION AND REVOCATION FOR NON PAYMENT 6, - PERMIT NUMBER W00007169 NW zR QUA I" .CALDWELL READY MIX, INC-WASHO ��Ffr�1'fL![�f,� JG7,� ��1ON IC- CALDWELL COUNTY Dear Permittee: Payment of the required annual administering and compliance monitoring fee of $300.00 for this year has not been received for the subject permit. This fee is required by -Title 15 North Carolina Administrative Code 2H.0105, under the authority of North Carolina General Statutes 143-215.3(a)(1), (1a) and (1 b). Because this fee was not fully paid within 30 days after being billed, this letter initiates action to revoke the subject permit, pursuant to 15 ncac 2H.01 05(b) (2) (k) (4), and G.S. 143-215.1 (b) (3). Effective 60 days from receipt of this notice, subject permit is hereby revoked unless the required Annual Administering and Compliance Monitoring Fee is received within that time. Discharges without a permit are subject to the enforcement authority of the Division of Water Quality. Your payment should be sent to: N.C. Department of Environment and Natural Resources Division of Water Quality Budget Office 1617 Mail Service Center Raleigh, NC 27699-1617 If you are dissatisfied with this decision, you have the right to request an administrative hearing within Thirty (30) days following recipt of this notice, identifying the specific issues to be contended. This request must be in the form of a written petition conforming to Chapter 1506 of the North Carolina'General Statutes, and filed with the Office of Administrative Hearings, Post Office Drawer 27447, Raleigh, North Carolina, 27611-7447. Unless such request for hearing is made or payments_ received; revocation shall be final and binding. If you have any questions, please contact: �Mr. F_orrest Westall, Asheville Water Quality_Reglon-1 Supervisor, (828)_251 6208. :Sincerely, �., , Kerr T. Stevens cc: Supevisor, Water Quality Permits and Engineering Unit Asheville Regional Office County Health Department P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-5083 FAX 919-733-9919 An Equal Opportunity Affirmative Action Employer 50% recycled / 10% post -consumer paper State of North Carolina Department of Environment and Natural Resources Division of Water Quality Non -Discharge Branch Permitting James B. Hunt, Jr., Governor Wayne McDevitt, Secretary A. Preston Howard, Jr., P.E., Director MICHAEL L. TRIPPLET CALDWELL READY MIX, INC-WASHO PO BOX 461 GRANITE FALLS, NC 28630 Dear Permittee: 0 - Am E3 FEN FI February 1.9, 1998 Subject: PERMIT NO. WQ0007169 CALDWELL READY MIX, INC-WASHO CALDWELL COUNTY Our files indicate that the subject permit issued on 12/8/93 expires on 11/30/98. We have not received a request for renewal from you as of this date. A renewal request shall consist. of a letter asking for permit renewal, the appropriate permit application processing fee, and four (4) copies of a completed application. For permitted facilities with treatment works, a narrative description of the residuals management plan, which is in effect at the permitted facility, must also be submitted with the renewal application. Applications may be returned to the applicant if not accompanied by the processing fee or are incomplete. Please find attached a copy of the processing fee schedule, as found in 15 NCAC 2H .0205(c). The processing fee for your facility is based on the type of facility and/or the permitted flow. Processing fees for land application of residuals are based on the total acres of land permitted. The processing fee does not apply to any farmer who submits an application which pertains to his/her farming operation._ The check or money order should be made payable to the North Carolina Department of Environment and Natural Resources (DENR). The Environmental Management Commission adopted rules on October 1, 1990, requiring the payment of an annual fee for most permitted facilities.- You will be billed separately for that fee (if applicable) after your permit is -approved. P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone (919) 733-7015 FAX (919) 733-2496 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper 6 - % Please be advised that this permit must not be allowed to expire. You must submit the renewal request at least 180 days prior to the permit's expiration date, as required by the 15 NCAC 2H .0211. Renewal requests received less than 180 days prior to permit expiration will be required to pay the full NEW APPLICATIONS/ MODIFICATION/ LATE RENEWALS fee rather than the reduced TIMELY RENEWALS WITHOUT MODIFICATIONS fee. Failure to request a renewal at least 180 days prior to the permit expiration date and/or operation of a facility without a valid permit may result in the assessment of civil penalties. NCGS 143-215.6 allows for the assessment of Civil penalties up to $10,000 per violation per day. The letter requesting renewal, along with the completed Non -discharge Permit Application and the appropriate processing fee, must be sent to: Permits and Engineering Unit Division of Water Quality Non -Discharge Branch Permitting P. O. Box 29535 Raleigh, North Carolina 27626-0535 If you have any questions concerning this matter, please contact Ms. Nancy Owens at 919/ 733- 5083 extension 574. Sincerely, Kim . Colson, P.E., Supervisor Non -Discharge Branch Permitting Unit cc: ,.Asheville -Regional Office Central Files State of North Ca ina Department of Environment, Health and Natural Resources Division of Water Quality James B. Hunt,,Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director Mr. Michael L. Triplett, President Caldwell Ready Mix, Incorporated P. O. Box 461 Granite Falls, North Carolina 28630 A4 WWI IDEHNF1 January 14, 1997 - Subject: NPDES Stormwater Permit Application Caldwell Ready Mix Corp. Return #838 j Application No. NCG140228�, g' Caldwell County i sx t JAN i 199 Dear Mr. Triplett: I On March 14, 1996, the Division of Water Quality received your Notice of Intent for NPDES Stormwater General Permit coverage under NCG140000 for stormwater discharges from the subject facility. In discussion with Bill Mills of the Stormwater Group concerning the Notice of Intent, you advised that stormwater runoff from your facility discharges to a large basin at this facility which operates under Permit No. WQ0007169 as a non -discharging system. Our Asheville Regional Office has recently visited your plant and has advised that due to the non -discharge system which receives your stormwater, this facility does not have a direct discharge to the waters of the state and does not need 'a NPDES permit. Based upon.these factors your Notice of Intent is being returned to you without any further processing actions herewith. Your application fee of $400, is being refunded to you under a separate cover. If you have questions concerning this matter, please contact Bill Mills of our Stormwater Group (919 / 7.33-5083 ext. 548). Sincerely, 4A, Bradley Bennett, Supervisor Stormwater Group Enclosu cc: Asheville Regional Office Permits and Engineering Central Files P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 FAX 919-733-9919 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper State of North. Carolina Department of .Environment, Health and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director Asheville Regional Office MEMORANDUM TO: THROUGH: FROM: SUBJECT: EDEHNR WATER QUALITY SECTION Bil-I , Sto For Reg Jim Ash January 7, 1997 Supervisor ice Caldwell Ready Mix Concrete Hudson Caldwell County In response to your memorandum (received October 29, 1996) concerning a stormwater permit for subject facility, I visited the site on January 5, 1997. Information gathered during the inspection revealed that Caldwell Ready Mix is operating a non discharge system for stormwater. Consequently, the facility does not need a stormwater discharge permit. The facility currently holds Non -Discharge _ Permit Number WQ0007169 and appeared to be operating substantially in compliance with the Permit's requirements.. One deviation from the permit was noted; the facility's owner had not installed the recycle equipment described in the permit. The employee onsite (Mike) at the time of inspection stated that - there had never been a discharge from the basin receiving both stormwater and water from equipment rinsing. Observation revealed no -evidence.of overflows from the basin. Sand, gravel and other settled materials are reportedly dredged from the -basin approximately twice per year. Dredged materials are given t(o individuals for us on driveways and roadways. Interchange Building, 59 Woodfin Place �M FAX 704-251-6452 Asheville, North Carolina 28801 N%f CAn Equal Opportunity/Affirmative Action Employer Voice 704-251-6208'50% recycles/ 10% post -consumer paper Bill Mills January 7, 1997 Page 2 into the ground within a couple of days. Such percolation seemed possible since the area draining to the basin was small and the dikes forming the basin were above grade on three sides. Apparently, sufficient freeboard exists to handle the Company's washwater during the period required for stormwater percolation. Caldwell Ready Mix is operating in compliance with the requirements of Non -Discharge Permit Number WQ0007169 (except for having constructed recycle equipment). Since the permit will expire next year, DWQ should not force the permittee to obtain a modified non -discharge permit at this time. Regional Staff will recommend removal of references to recycle equipment at the time of permit renewal in 1998. Since the facility does not discharge stormwater, a general permit for stormwater.will not be required. Your attention to this matter is appreciated. Please contact me if additional information is required. % ft 0 t ber 22 1996 Watery Q ualit Section 9, 1 IEVI����GR11iys REGlO�,rgfC„ G� Memo To: Forrest Westall Regional Engineer, AsY eville Regional Office From: Bill Mills Stormwater Group Subject: Caldwell Ready Mix Concrete Hudson Caldwell County We have pending a NOI for a Stormwater permit from Caldwell Ready Mix, in Hudson. The NOI indicates no discharge of stormwater. I called Mr. Triplette and discussed where his stormwater drains and whether he had a point source discharge of stormwater from the existing operations. He explained that all of the runoff goes to the rear of the property into a huge basin from which there is no discharge except seepage. He also holds non -discharge permit no. WQ0007169 that describes a system of basins and pumps for treatment and reuse of the washwater from this plant. I asked him about that system and he advised that they never built that system, it all looked too complicated. He sends his washwater from the trucks and equipment to the same large basin from which there is apparently no discharge. About every year or two he sends a dragline or backhoe of some type down there and cleans the sand and stone out of the basin. If this facility needs a discharge permit for stormwater and/or washwater, the NCG1400000 permit can cover it. The GP has allowance for the discharge of both stormwater and for discharge of rinse water associated with vehicle and equipment cleaning from these ready mix plants. If he is effective operating a non -discharge system for stormwater that is not a problem, there is no permit required for the stormwater systems that operate without a point source discharge up to the 25 yr, 24 hr. storm. I would appear that some alteration to WQ0007169 may be in order for the washwater. Please advise concerning your recomendations as to whether a NPDES permit is appropriate for this facility. (He already has one permit from us he is not using, I don't want to compound things. by issuance of the incorrect permit. Your assistance in this matter is appreciated. Attachments NOI WQ0007169 cc: Carolyn McCaskill j I PPPP PPP f , '�_Xo � 4coq:�' NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM NOTICE OF INTENT. REQUESTING. COVERAGE UNDER GENERAL PERMIT NO. NCG140000 STORMWATER DISCHARGES associated with activities classified as Ready Mixed Concrete [Standard Industrial Classification Code (SIC) 3273]. Complete this Notice of Intent (NOI) and mail to the following address: North Carolina Division of Environmental Management Water Quality Section, NPDES Group P.O. Box 29535 Raleigh, North Carolina 27626-0535 The NOI must be accompanied with a general permit filing fee of $400.00 and a copy of a county map or USGS quadwith the location of the facility clearly marked on the map. The check should be made out to the North Carolina Department of Environment, Health, and Natural Resources. to Portable ready mixed concrete facilities may begin operation upon submittal of a Notice of Intent (NOI) and implementation of a stormwater pollution prevention plan. Portable plants are defined installation for the of dedicating at least 75% of all materials to a as a temporary plant purpose specific job or a plant which continuously occupies a site for a period of six months or less. New permanent installations are required to submit a NOI 90 days prior to beginning industrial ,v activities. C. cv' y I. General Facility Information 1. Answer the following questions by indicating the appropriate response (yes or no) with a check mark in the space provided to the right of each question: a. Does this facility have any NPDES Permits? Yyes no b. Does this facility have any Non -Discharge permits (ex: recycle permits)? _yes Xno c. Are vehicle maintenance activities occurring on site? _yes no . d. Are any best management practices employed for stormwater control? _ yes no e. Is this an existing facility? Xyes no f. Is this facility a Hazardous Waste Treatment, Storage, or Disposal facility? _►es apo g. Is this facility a Small Generator of Hazardous Waste? ___yes kno h. Does this facility use molds to produce cast concrete products? _yes Ino 2. List the permit numbers for all current NPDES and Non -Discharge permits for this facility. NOI 14 Page 1 of 3 Pages 3 . ' If this is a proposed facility, list the date operatianAs-sehe�uled to begin : 4. How many stormwater discharge poin"'tches, pg g, ch�(nnels, -etc. that convey stormwater .from the property) does the facility ha e? �lJ UIV 5. What is the name of the body or bodie of water c , stream, river, lake, etc.) that the facility stormwater discharges end up in? a site stormwater discharges to a separate storm sewer system, name the operator of the separate storm sewer system (e.g. City of Raleigh municipal storm sewer). II. Facility Owner/Operator Information Provide the following location information for the owner/operator of the facility. This may or may not be the. same as the facility location information. Name: Address: -1134E C'G�f',C/��' V(4 --V 1,44" City: aX14 1 /T e- State:. 41 e Zip: / 3 G Phone: ( 7 $/ Sf""; CALDWELL READY M!X INC. � III. Facility Location Information � P.D. BOX41 GRANITE FALLS, N.C. 28630 Fill in the appropriate requested facility location information in the spaces provided. Do not write "same as above" or leave any blank spaces. Facility Name: w4c� A /,Y 2' A/ e - Contact: Address: liSSicrtl City: /j s 0 ,f State: 'y e_ Zip: ae6 3� County:/j W /, L Phone( 7v oma, ) 19 Provide a narrative description of how to get to the facility (use street names, state road numbers, and distance and direction from a roadway intersection). Narrative Description of Facility Location: T /,�c�iY) �/T� y T�" J�/}iL S GN ✓ S 3'..`Z / .1/C A Tf/. ��=� M ! s. �: s To jV/7g5ZFCTllc� ni 6� /h/SS/CN /t0,4,0 Ti4, .(E r T %'!,/ AIT is o:/ IV. Industrial Activity Provide the 4 digit Standard Industrial Classification Code (SIC Code) that describes the primary industrial activity at this facility: SIC Code Nc� / yc oco NOI 14 Page 2 of 3 Pages PPPPP 7'P Provide a brief narrative description of the types of industrial activities and products manufactured at this facility: V. Certification I hereby request coverage under the referenced General Permit. I understand that coverage under this permit will constitute the permit requirements for the discharge(s) and is enforceable in the same manner as an individual permit. . . I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. Signature print or type name of person signing above date title North Carolina General Statute 143-215.6(B)(2) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained-under:Article 21 or regulations of the Environmental Management Commission implementing' .that Article, shall be guilty of a misdemeanor punishable:by a fine not to exceed $10;000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides'a punishment by a fine of not more than $10,000 or imprisonment not more than 5 years, or both, for similar offense.) NOI 14 Page 3 of 3 Pages