Loading...
HomeMy WebLinkAboutWQ0040621_Application (FTSE)_20190206COUMPA January 15, 2019 State of North Carolina Department of Environmental Quality Division of Water Recourses 2090 US Highway 70 Swannanoa, North Carolina 28778 RE: Cummings Cove Phase IX Fast Track Sewer System Extension Permit CDC Project No. 21803 Dear Reviewer: Please find enclosed a fast track sewer system extension permit application package for the subject project for your review and approval. The Cummings Cove Phase IX subdivision will consist of 28 residential units within the overall Cumming Cove master plan development. The project is located at 299 Cummings Ridge Trail in Henderson County. Please find enclosed the following items for your review and approval: • Check in the amount of $480.00 • Set of sealed 24" x 36" plans • FTA 04-16 Fast Track Sewer Application • DEV 11-17 Developer's Operation Agreement • FTSE 04-16 Flow Tracking Acceptance Application • Site Map Please do not hesitate to call if you have any questions or need any additional information during your review. Sincerely, Mic 1 Cain, PE Civil Design Concepts, PA tVa9n neoour , JAN 2 5 2019 t Mailing Address: P.O. Box 5432, Asheville, NC 28813 168 Patton Avenue, Asheville, NC 28801 52 Walnut Street Suite 9, Waynesville, NC 28786 Phone 828-252-5388 Fax 828-252-5365 Phone: 828-452-4410 Fax: 828-456-5455 State of North Carolina DWR Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 - FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Divlslon of Water Resources INSTRUCTIONS FOR FORM: ETA 04-16 & SUPPORTING DOCUMENTATION This application is for sewer extensions involving gravity sewers, pump stations and force mains, or any combination that has been certified by a professional engineer and the applicant that the project meets the requirements of 15A NCAC 02T and the Division's Minimum Design Criteria and that plans, specifications and supporting documents have been prepared in accordance with, 15A NCAC 02T, 15A NCAC 02T.0300, Division policies and good engineering practices. While no upfront engineering design documents are required for submittal, in accordance with 15A NCAC 02T .0305(b), design documents must be prepared prior to submittal of a fast track permit application to the Division. This would include plans, design calculations, and project specifications referenced in 15A NCAC 02T .0305 and the applicable minimum design criteria. These documents shall be available upon request by the Division. Projects that are deemed permitted (do not require a permit from the Division) are explained in 15A NCAC 02T.0303. Projects not eligible for review via the fast track process (must be submitted for full technical review): ➢ Projects that require an environmental assessment in accordance with 15A NCAC 1C .0100; ➢ Projects that do not meet any part of the minimum design criteria (]!MC) document; ➢ Projects that involve a variance from the requirements of 15A NCAC 2T; ➢ Pressure sewer systems utilizing septic tank -effluent pumps (STEPS) or simplex grinder pumps; ➢ STEP or simplex grinder pumps connecting to pressurized systems (e.g. force mains); ➢ Vacuum sewer systems. General— When submitting an application, please use the following instructions as a checklist in order to ensure all required items are submitted. Adherence to these instructions and checking the provided boxes will help produce a quicker review time and reduce the amount of requested additional information. Failure to submit all required items will necessitate additional processing and review time, and may result in return of the application. Unless otherwise noted, the Applicant shall submit one original and one copy of the application and supporting documentation. A. One Original and One Copy of Application and Supporting Documents ® Required unless otherwise noted B. Cover Letter (Required for All Application Packages): ® List all items included in the application package, as well as a brief description of the requested permitting action. m Be specific as to the system type, number of homes served, flow allocation required, etc. m If necessary for clarity, include attachments to the application form. C. Application Fee (All New and Major Modification Application Packages): ® Submit a check or money order in the amount of $480.00 dated within 90 days of application submittal. A Payable to North Carolina Department of Environmental Quality (NCDEQ) D. Fast Track (Form: ETA 04-16) Application (Required for All Application Packages): M Submit the completed and appropriately executed application. A If necessary for clarity or due to space restrictions, attachments to the application may be made. M If the Applicant Type in Item I.2 is a corporation or company, provide documentation it is registered for business with the NorOl Carolina Secretary of State. 1� If the Applicant Type in Item I.2 is a partnership or d/b/a, enclose a copy of the certificate filed with the Register of Deeds in the county of business. M The Project Name in Item II.I shall be consistent with the project name on the flow acceptance letters, agreements, etc. M The Professional Engineer's Certification on Page 5 of the application shall be signed, sealed and dated by a North Carolina licensed Professional Engineer. M The Applicant's Certification on Page 5 of the application shall be signed in accordance with 15A NCAC 02T 0106(b). Per 15A NCAC 02T .0106(c), an alternate person may be designated as the signing official if a delegation letter is provided from a person who meets the criteria in 15A NCAC 02T .0106(b). INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 1 of 3 E. Flow Tracking/Acceptance Form (Form: FTSE 04-16) (If Applicable): ® Submit the completed and executed FTSE form from the owners of the downstream sewers and treatment facility. ➢ Multiple Forms maybe required where the downstream sewer owner and wastewater treatment facility are different. ➢ The flow acceptance indicated in form FTSE must not expire prior to permit issuance and must be dated less than one year prior to the application date. ➢ Submittal of this application and form FTSE indicates that owner has adequate capacity and will not violate G.S. 143- 215.67(a). ➢ Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific FTSE. F. Site Maps (All Application Packages): ® Submit an 8.5-inch x 11-inch color copy of a USGS Topographic Map of sufficient scale to identify the entire project area and closest surface waters. ➢ Location of the project (gravity sewer, pump stations & force main) Downstream connection points and permit number (if known) for the receiving sewer ® Include a street level map (aerial) showing general project area so that Division staff can easily locate it in the field. G. Existing Permit (All Modification Packages): ❑ Submit the most recently issued existing permit. ❑ Provide a list of any items within the permit the Applicant would like the Division to address during the permit modification (i.e., permit description, flow allocation, treatment facility, etc.). H. Power Reliability Plan (Required if portable reliability option utilized for Pump Station): ❑ Per 15A NCAC 02T.0305(h)(1), submit documentation of power reliability for pumping stations. This alternative is only available for average daily flows less than 15,000 gallons per day It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant and is compatible with the station. The Division will accept a letter signed by the applicant (see 15A NCAC 02T .0I06(b)) or proposed contractor, stating that "the portable power generation unit or portable, independently -powered pumping units, associated appurtenances and personnel are available for distribution and operation of this pump station." If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. (Required at time of certification) 1. Certificate of Public Convenience and Necessity (All Application Packages for Privately -Owned Public Utilities): ® Per 15A NCAC 02T .0115(a)(1) provide the Certificate of Public Convenience and Necessity from the North Carolina Utilities Commission demonstrating the Applicant is authorized to hold the utility franchise for the area to be served by the sewer extension, or ❑ Provide a letter from the North Carolina Utilities Commission's Water and Sewer Division Public Staff stating an application for a franchise has been received and that the service area is contiguous to an existing franchised area or that franchise approval is expected. J. Operational Agreements (Applications from HOA/POA and Developers for lots to be sold): ❑ Home/Property Owners' Associations ❑ Per 15A NCAC 02T .0115(0), submit the properly executed Operational Agreement (FORM, HOA). ❑ Per 15A NCAC 02T .01 15(c), submit a copy of the Articles of Incorporation, Declarations and By-laws. ® Developers of lots robe sold ® Per 15A NCAC 02T .0115(b), submit the properly executed Operational Agreement (FORM: DEV). For more information, visit the Division's collection systems website INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 2 of 3 THE COMPLETED APPLICATION PACKAGE INCLDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office 2090 US Highway 70 Avery, Buncombe, Burke, Caldwell, Cherokee, Water Quality Section Swannanoa, North Carolina 28778 Clay, Graham, Haywood, Henderson, Jackson, (828) 296-4500 Macon, Madison, McDowell, Mitchell, Polk, (828) 299-7043 Fax Rutherford, Swain, Transylvania, Yancey Fayetteville Regional Office 225 Green Street Suite 714 Anson, Glacier, Cumberland, Harnett, Hoke, Water Quality Section Fayetteville, North Carolina 28301-5094 Montgomery, Moore, Robeson, Richmond, (910)433-3300 Sampson, Scotland (910)486-0707 Fax Mooresville Reaional Office 610 E. Center Avenue Alexander, Cabarms, Catawba, Cleveland, Water Quality Section Mooresville, North Carolina 28115 Gaston, Iredell, Lincoln, Mecklenburg, Rowan, (704)663-1699 Slanly, Union (704)663-6040 Fax Raleigh Regional Office 1628 Mail Service Center Chatham, Durham, Edgecombe, Franklin, Water Quality Section Raleigh, North Carolina 27699-1628 Granville, Halifax, Johnston, Lee, Nash, (919) 791-4200 Northampton, Orange, Person, Vance, Wake, (919) 788-7159 Fax Warren, Wilson Washinaton Reaional Office 943 Washington Square Mall Beaufort, Berrie, Camden, Chowan, Craven, Water Quality Section Washington, North Carolina 27889 Curriluck, Dare, Gales, Greene, Hartford, Hyde, (252) 946-6481 Jones, Lenoir, Martin, Pamlico, Pasquotank, (252) 975-3716 Fax Perqulmans, Pitt, Tyrrell, Washington, Wayne Wilmington Regional Office 127 Cardinal Drive Extension Brunswick, Carteret, Columbus, Duplin, New Water Quality Section Wilmington, North Carolina 28405 Hanover, Onslow, Pander (910)796-7215 (910)350-2004 Fax Winston-Salem Reaionet Office 450 W. Hanes Mill Road Suite 300 Alamance, Allegheny, Ashe, Caswell, Davidson, Davie, Forsyth, Guilford, Rockingham, Randolph, Water Quality Section Winston-Salem, North Carolina 27105 Stokes, Sorry, Watauga, Wilkes, Yadkin (336)776-9800 s JAAl ? goons INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 3 of 3 State of North Carolina D� 1 ]� Department of Environmental Quality WDivision of Water Resources 15A NCAC 02T .0300 - FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: (m be completed by DWR) All items must be completed or the application will be returned L APPLICANT INFORMATION: 1. Applicant's name: FUL TRACK. LLC (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ hrdividual ® Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ Stale/County ❑ Municipal ❑ Other 3. Signatrue authority's name: GEORGE ELMORE per 15A NCAC 02T 01 O6(b) Title: MANAGER Fw- sian of avatar Flesources 4. Applicant's mailing address: 95 DEPOT STREET City: WAYNESVILLE State: NC Zip:28786-_ JAN 2 5 20195. Applicant's contact information:Phone number:(561) 704-5463 Email Address: mcam(ocdceo.com uallty Regional Operations 11. PROJECT INFORMATION: 1. Project name: Cummings Cove Phase IX 2. Application/Project sums: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQOOT and issued date: If new consurction but part of a master plan, provide the existing permit number: W000 3. County where project is located: Henderson .4. Approximate Coordinates (Decimal Degrees): Latitude: 35.3157° Longitude:-82.5557' 5- Parcel ID (if applicable): 9549-00-4242 (or Parcel ID to closest downstream sewer) IH. CONSULTANT INFORMATION: I - Professional Engineer: Michael Cain License Number: 047788 Finn: Civil Design Contents Mailing address: 168 Patton Ave City: Asheville State: NC Zip: 28801-_ Phone number: (828) 252-5388 Email Address: mcain(ncdceo.com IV- WASTEWATER TREATMENT FACILITY(WWTF) INFORMATION: 1— Facility Name: Cummins Cove Permit Number: NCO057541 Owner Name: Cummings Cave Company. LLC V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTE: 1 Permit Number(s): WQ Downstream (Receiving) Sewer Size: _ inch System Wide Collection System Permit Number(s) (if applicable): WQCS_ Owner Name(s): FOR": FTA04-16 page 1 of VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Amarnent (FORM: DEVI been attached? ® Yes [-]No ❑N/A 3. If the Applicant is a Hone/Property Owners' Association has an Operational Agreement (FORM: HOA) been attached? 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Residential Leased ❑ School / preschool / day care ❑ Food and drink facilities ❑ Businesses / offices / factories ❑ Yes ❑No ®N/A ❑ Retail (stores, centers, malls) ❑ Retail with food preparation/service ❑ Medical / dental / veterinary facilities ❑ Church ❑ Nursing Home 5. Nature of wastewater: 100 % Domestic/Commercial %Commercial ❑ Car Wash ❑ Hotel and/or Motels ❑ Swimming Pool /Clubhouse ❑ Swimming Pool/Filter Backwash ❑ Other (Explain in Attachment) I % Industrial (See 15A NCAC 02T.0103(20)) '—its there a Pretreatment Program in effect? ❑ Yes ® No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(t)7 ❑ Yes ® No ➢ If yes. Provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(fl) Daily Design Flow'•" No. of Units Flow Residential (3-bedroom units) 360 gal/unit/day 28 10080 PD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 101080 dPD a See 15A NCAC 02T .0114(b), (d) (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east ofthe Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01 I I shell be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 1Q080GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: ETA 04-16 Page 2 of VH. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 262 SDR 35 8 520 DIP �a ➢ Section lI & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related W minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Punn) Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 1 2. Approximate Coordinates (Decimal Degrees): Latitude: 35.3155' Longitude:-82.5548° 3. Design Flow of the pump station:.0112 millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): 30 gallons per minute at 117.6 feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 2 500 PVC 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(D: ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B): ➢ Required for all pump stations with an average daily Dow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ® Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations'storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): I. Does the project comply with all separations found in 15A NCAC 02T 0305(f) & (e) ® Yes ❑ No D t GA MCA n?T 01(1S(A rnnrainc minim,..,..P..nwri— tl.or h.11 I.P­4d1 d f­ eP,vrr cvcfP.me Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains (horizontal) 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet **Any private or public water supply source, including any wells, WS-1 waters of Class I or Class rI impounded reservoirs used as a source of drinking water 100 feet **Waters classified W S (except W S-I or W S-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item IX.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Amy basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feel Final earth grace vertical 36 inches ➢ 15A NCAC 02T.0305(g) contains alternatives where separations in 02T 0305(l) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webnage ➢ If noncompliance with 02T.0305(t) m(a), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ❑ No ® N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rates per l5A NCAC 02B .02009 ❑ Yes ❑ No ® N/A ➢ This would include Trout Buffered Streams per l5A NCAC 213.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.04021 "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permitter or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria frn the Perm'tfne f P p St f n and Force Mains (latest version), and, the Gravi Sewer Minimum Desien Criteria (latest version-1 as applicable? ® Yes ❑ No If No, complete and submit the VmiancdAltemative Design Request application (VADC 10-14) and supporting documents for review. Approval of the reauestis rearifired Prior tosubmittal of the FastTrack Application ad supporting documents 2. Professional Engineer's Certification: that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has bean prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria fro the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and havejudged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6E, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: SEAL 0;7750 y,,'FI'GIPd`F� c'L J G 3. Applicant's Certification per 15A NCAC 02T .0106(b): 1, Peorge T. Elmore Manager attest that this application for (Signature Authority's name & title from Application Item 1.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required Parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that my include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B. any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: GEORGET. ELMORE JAM ro 2 FORM: FTA 04-I6 Page 5 of State of North Carolina Department of Environmental Quality Division of Water Resources ' Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: FUL TRACK, LLC Project Name for which flow is being requested:. CUMMINGS COVE PHASE IX More than one FTSE tray be required for a single project ljthe owner of the WWTP la not responsible for all pump stations along the route ofthe proposed IVastewaterflow. 1. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Cummings Cove b. WWTP Facility Permit #: NCO057541 All flows are in MGD c. WWTP facility's permitted flow. 0.08 MGD d. Estimated obligated flow not yet tributary to the WWTP 0.00052 e. WWTP facility's actual avg. flow 0.035648 f. Total flow for this specific request 0.011, g. Total actual and obligated flows to the facility 0.046648 h. Percent of permitted flow used 42% �,/ 11. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow** Can ant Trib a Flow Plus (Name or Permit Capacity,* (Firm /pf), Avg. Daily Dail Flow, Obligated Available Number) No. MGD MGD Flow, MGD GD br jV(" Capacity*** 5 0.0002r--�'""'� 0.001 `JA..IV -� 0.001 U,-. Z 8 * The Firm Capacity (design Dow) of any pump station is defined as that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall he attached for each pump station located between the project connection point and the WWTP where the Available Capacity is <0. Downstream Facility Name (Sewer): Downstream Permit Number: NCO057541 Page 1 of 6 FTSE 10-18 III. Certification Statement: I JUANITA DAMES certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. 1�7 Signing Title offigning OJrcial Page 2 of 6 PTSE 10-18 VICINITY MAP FOR: NOT TO SCALE rxoxewn �... CUMMINGS COVE PHASE IX CDC01va -- Concepts, PA CDC PROJECT #21803 c.euucE.u. STATE OF NORTH CAROLINA COLJNTY0p HENDERSON permit No. DEVELOPER'S OPERATIONAL AGREEMENT This AGREEMENT made pursuant to G.S. 143-215.1 (dl) and entered into this day of by and between the North Carolina Environmental Management Commission, an agency of the State of North Carolina, hereinafter known as the COMMISSION; and FUL TRACK, LCC , a corporation/general partnership registered/licensed to do business in the State of North Carolina, hereinafter known as theDEVELOPER. WITNESSETH: 1. The DEVELOPER is the owner of the certain lands lying in H EN DERSON County, upon which it is erecting and will erect dwelling units and other improvements, said development to beknown as CUMMINGS COVE PHASE IX (hereinafter the Development). 2- The DEVELOPER desires, to construct a wastewater collection system with pumps, wastewater treatment works, and/or disposal facilities (hereinafter Disposal System) to provide sanitary sewage disposal to serve the Development on said lands. 3. The DEVELOPER has applied to the COMMISSION for the issuance of a permit pursuant to G.S. 143- 21 5.1 to construct, maintain, and operate the Disposal System. 4, The DEVELOPER has created or shall create unit ownership in said dwellings units, other improvements amid lands through filing of a Declaration of Unit Ownership (hereinafter Declaration), pursuant to Chapter 47C or47F of the North Carolina General Statutes. 5, The DEVELOPER has caused to be formed or will cause to be formed at the time of filing of the Declaration, the Unit Owners' Association (hereinafter Assodation), a non-profit corporation organized and existing under and by the virtue of the laws of the Stale Of. Nodh Carolina, for the purpose, among others, of handling the property, affairs and business of the De-'elopmem; of operating, maintaining, re -constructing and repairing the common elements of the lands and improvements subject to unit ownership, including the Disposal System; and of collecting dues and assesrcnents to provide funds for such operation, maintenance, re -construction andrepair. 6. TI3e; COMMISSION desires to assure that the Disposal System of the Development is properly constructed, "'o-4—Etimsined and operated in accordance with law and permit provisions in order to protect the quality of the wg*.o of the State and the public interest therein. NOW, TIFIEREFORE, in consideration of the promises and the benefits to be derived by each of the parties hereto, *f4tCOMMISSION and DEVELOPER do hereby mutually agree as follows: 1. and ance with the permit an T�eDEVELOPER shall construct the Disposal System in accordeCplans erate s1I�afications hereafter issued and approved by the COMMISSION, and shall thereafter prop y P a�clmaintain such systems and facilities in accordance with applicable permit provisions andlaw. 2. T'i�XeDEVELOPER shall not transfer ownership and/or control of the Disposal System to the Association u17W'I-iconstruction has been completed in accordance with the permit and approved plans, and the staff of the Division of Water Resources has inspected and approved of the facilities. In order to change the name oE�— lit permit holder, the DEVELOPER must request that the permit be reissued to the Association. The Teagast must include a copy of the Association Bylaws andDeclaration. 3' T�eDEVELOPER shall not transfer, convey, assign or otherwise relinquish or release its responsibility for tJ3L`-14z�Qperation and maintenance of its Disposal System until a permit has been reissued to the DEVELOPER's SLR*pCssor.