Loading...
HomeMy WebLinkAboutNC0079057_Compliance Evaluation Inspection_20190130 p A. -,1"'„',..sart:\ "0,4 ,,,,,,,,,,..„.,44* ROY COOPER t .•,-. MICHAEL So REGAN > .,e secretary - .. ° �t LINDA CULPEPPER NORTH CAROLINA Direaar Environmental Quality January 30, 2019 Josh O'Brien Town of Manteo ' PO Box 246 Manteo, NC 27954-0246 SUBJECT: Compliance Inspection Report Manteo WWTP NPDES WW Permit No. N00079057 Dare County Dear Mr. O'Brien: -------------------------- The North Carolina Division of Water Resources conducted an inspection of the ManteoWWTP on 1/29/2019. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0079057. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". j There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. If you should have any questions, please do not hesitate to contact Stewart White with the Water Quality Regional Operations Section in the Washington Regional Office at 252-946-6481 or via email at stewart.white@ncdenr.gov. - Sincerely, -- Stewart White, Environmental Specialist I Water Quality Regional Operations Section Washington Regional Office Division of Water Resources, NCDEQ 1E $ tQrth , s D psrtn tof Enrar r er-talQ &ty Lk,ess a cf Water Res_«r s lt� `sue gtn:11:.e rYsiOff a yr 037 a:;t:a.t .sr_I:1) i 1S'_c.ft.toera,North mars+,>x 27888 • VI . 1 ATTACHMENTS Cc: WQS Washington Regional Office NPDES Compliance/Enforcement Unit - . - , . i , 1 - 1 1 1 , 1 I 1 i , 1 1 . I , ! 1 „ . ' . - ! . . ! „ _ 1 . , . . .2, vN:rthh,Caetmi,n_,a 0,eps ft,orrff.e.rtt If ET.,c7r7nta:gt:a±tyr I mi-d's-vs1.7,"fhW7r Rriescith jurcer: ,rt a. 2issa, D. ...40------11/4 ,,,„,..„........-...„-\..„.„ 2524148-6A61 United States Environmental Protection Agency Form Approved E PA Washington,D C 20460 OMB No 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A National Data System Coding(i.e,PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 1ti 1 2 15 1 3 I NC0079057 111 121 19/01/29 117 18 r. 19 W 201 I 21 I I I I I I I I I I I I 1 1 l l l I I I I I I I I ,I I I I I I I I I I I I I I I I I r6 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA -Reserved 67I I 70I5 I 71I I 72 1 I1 731 I 174 "I I I I I I I 1 l80 Section B Facility Data �J Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 10 15AM 19/01/29 13/04/01 Manteo WWTP 710 Bowsertown Rd Exit Time/Date Permit Expiration Date Manteo NC 27954 12 05PM 19/01/29 17/12/31 Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /// Joshua J O'Brien/ORC/252-473-3513/ Name,Address of Responsible Official/Title/Phone and Fax Number ------------ ---------------- ------------------------ ----- -- --� Contacted- ---- —�- -� Nathan_Pharr,PO Box 246_Manteo NO 279540246//252-305-3491/ No Section C Areas Evaluated During Inspection(Check only those areas evaluated) El Permit II Flow Measurement Operations&Maintenance MI Records/Reports IN Sludge Handling Disposal III Facility Site Review Effluent/Receiving Waters Section D Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) , • Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date Stewart White WARO WQ//252-948-3940/ ) Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3(Rev 9-94)Previous editions are obsolete • Page# 1 NPDES yr/mo/day Inspection Type (Cont) 1 31 NC0079057 Ill 121 19/01/29 117 18 u . Section D Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) The Facility was built in 1992 and has been well maintained Stewart White, Sarah Toppen,and Robert Tankard from the Washington Regional Office along with Emily Phillips from Raleigh Central Office met with ORC Josh O'Brien,Back-up ORC Victor Quick and Walter Liverman operator.The Inspection went very well and the final Effluent looks very good The WWTP was clean and well operated. See questions attached for details Atlantic Sewage Control was hauling sludge Arabic Digester was almost empty Environmental Chemists, Inc Leases the Lab from the Town of Manteo at this facility. Permit#NC0079057 was found to be compliant. . - ---- -- -------- --- --- ---------- --- Page# 2 Permit: NC0079057 Owner-Facility Manteo WWTP Inspection Date: 01/29/2019 Inspection Type. Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less) Has the permittee submitted a new • ❑ ❑ ❑ application? Is the facility as described in the permit? • ❑ El El #Are there any special conditions for the permit? ❑ ❑ E El Is access to the plant site restricted to the general public? • ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? • ❑ El ❑- Comment Permit Expired December 31,2017 Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? • 0 0 ❑ Is all required information readily available, complete and current? • ❑ 0 El l Are all records maintained for 3 years(lab. reg required 5 years)? • ❑ 0 0 Are analytical results consistent with data reported on DMRs? ■ 0 0 0 Is the chain-of-custody complete? II El ❑ 0 — — Dates,times and location of sampling ❑ Name of individual performing the sampling ❑ Results of analysis and calibration El Dates of analysis 0 Name of person performing analyses 0 Transported COCs ❑ Are DMRs complete do they include all permit parameters? • El ❑ 0 Has the facility submitted its annual compliance report to users and DWQ? • ❑ 0 ❑ (If the facility is=or>5 MGD permitted flow)Do they operate 24/7 with a certified operator ❑ El ■ El on each shift? Is the ORC visitation log available and current? - • ❑ ❑ 0 Is the ORC certified at grade equal to or higher than the facility classification? U ❑ ❑ El Is the backup operator certified at one grade less or greater than the facility classification? IN 0 El ❑ Is a copy of the current NPDES permit available on site? e ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? • ❑ El El Comment Reviewed eDMRs April 2018 and October 2018 with Lab Results Facility records are neat and well maintained ORC DMR Log book and operators record were reviewed Bar Screens Yes No NA NE Type of bar screen Page# 3 i ) Permit: NC0079057 - Owner-Facility: Manteo VVVVfP Inspection Date: 01/29/2019 Inspection Type: Compliance Evaluation Bar Screens Yes No NA NE a Manual b.Mechanical • Are the bars adequately screening debris'? 11 ❑ ❑ ❑ Is the screen free of excessive debris'? II ❑ ❑ ❑ Is disposal of screening in compliance'? • ❑ ❑ ❑ Is the unit in good condition? • ❑ ❑ ❑ Comment: 1 Grit Removal Yes No NA NE Type of grit removal • a Manual ❑ i b Mechanical • Is the grit free of excessive organic matter'? • ❑ ❑ ❑ Is the grit free of excessive odor? __ ___ • 0 ❑ ❑ #Is disposal of grit in compliance'? • 0 0 ❑ Comment Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory'? ❑ ❑ 0 Are all other parameters(excluding field parameters)performed by a certified lab'? II ❑ ❑ 0 #Is the facility using a contract lab? • ❑ 0 ❑ ) #Is proper temperature set for sample storage(kept at less than or equal to 6 0 degrees • ❑ ❑ ❑ Celsius)? Incubator(Fecal Coliform)set to 44 5degrees Celsius+/-0 2 degrees'? ❑ ❑ ❑ • Incubator(BOD)set to 20 0 degrees Celsius+/-1.0 degrees'? ❑ ❑ ❑ Comment. Facility has contract Lab on site Envirochem Services, Inc Influent and Effluent samplers were both 4 degrees celsius Oxidation Ditches Yes No NA NE Are the aerators operational? - • ❑ ❑ ❑ Are the aerators free of excessive solids build up? • ❑ 0 ❑ #Is the foam the proper color for the treatment process'? • ❑ ❑ ❑ Does the foam cover less thah 25%of the basin's surface? • ❑ ❑ ❑ Is the DO level acceptable'? • ❑ ❑ ❑ Page# 4 - 1/ f Permit: NC0079057 Owner-Facility: Manteo WWTP Inspection Date: 01/29/2019 Inspection Type: Compliance Evaluation Oxidation Ditches Yes No NA NE Are settleometer results acceptable(>30 minutes)? ❑ ❑ ❑ • Is the DO level acceptable?(1 0 to 3 0 mg/I) • ❑ ❑ ❑ Are settelometer results acceptable?(400 to 800 ml/I in 30 minutes) ❑ ❑ ❑ Comment DO Probe set 1'8-2.6 DO Range MLSS 3400 mg/I/ORC SCADA linked to Rotating Aeration Basin Pumps-RAS-WAS Yes No NA NE Are pumps in place? • ❑ ❑ 0 Are pumps operational? • 0 0 0 Are there adequate spare parts and supplies on site'? • ❑ ❑ ❑ Comment: Sludge was being hauled by Atlantic Sewage Control The Sludge is haul twice/year Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater'? ■ ❑ ❑ ❑ Is-the-site-free-of-excessive-burldup-of-Solids-in-center well-of-circular clarifier'?_ - —r❑-❑—❑- ---- I Are weirs level? _ � ❑___- ❑ ❑_ _ _ -- -- -- -------------____ Is the site free of weir blockage? 0 ❑ ❑ ❑ Is the site free of evidence of short-circuiting'? • ❑ ❑ ❑ Is scum removal adequate'? • ❑ 0 0 Is the site free of excessive floating sludge? ❑ • ❑ ❑ Is the drive unit operational'? • ❑ ❑ 0 Is the return rate acceptable(low turbulence)? III ❑ ❑ 0 Is the overflow clear of excessive solids/pin floc'? • ❑ ❑ ❑ Is the sludge blanket level acceptable?(Approximately'/4 of the sidewall depth) • 0 0 0 Comment. 2 Feet# 1 Clarifier and 4 Feet#2 Clarifier Clarifiers had some scum floating on surface of clarifiers but the Effluent going over the weirs looked very good going to filters Flow Measurement- Effluent Yes No NA NE #Is flow meter used for reporting'? • ❑ ❑ ❑ Is flow meter calibrated annually'? • 0 0 ❑ Is the flow meter operational'? • ❑ ❑ ❑ (If units are separated)Does the chart recorder match the flow meter'? ❑ ❑ MI ❑ Page# 5 } Permit: NC0079057 Owner-Facility: Manteo VVWTP Inspection Date. 01/29/2019 Inspection Type: Compliance Evaluation Flow Measurement-Effluent Yes No NA NE Comment Ultrasonic Flow meter calibrated by Delta Systems 10/8/18 133 qpm flow at time of inspection Effluent has probe monitoring pH, Temp , and DO 10.50am Displayed pH 7.05,Temp 12.6 deqrre celsius, and 9.87 DO Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? • ❑ ❑ 0 Are the receiving water free of foam other than trace amounts and other debris? • 0 0 0 If effluent (diffuser pipes are required) are they operating properly? 0 ❑ • 0 Comment. Outfall line is offshore and has a marker about 300-400 yards offshore Sand Filters (Low rate) Yes No NA NE (If pumps are used)Is an audible and visible alarm Present and operational? • 0 0 0 Is the distribution box level and watertight? - • 0 0 ❑ Is sand filter free of priding? 0 ❑ MI 0 Is the sand filter effluent re-circulated at a valid ratio? ❑ ❑ • ❑ - ----------#Is-the sand-filter surface-free of algae-or excessive vegetation? -❑---❑--❑--------- --- #Is the sand filter effluent re-circulated at a valid ratio?(Approximately 3 to 1) 0 ❑ ❑ • Comment. Sand Filter is a High Rate. ORC turn filter on manually to see it backwash Effluent looks great { Standby Power Yes No NA NE Is automatically activated standby power available? 111 ❑ 0 ❑ Is the generator tested by interrupting primary power source? ❑ ❑ ❑ I Is the generator tested under load? IM ❑ 0 ❑ Was generator tested&operational during the inspection? ❑ ❑ ❑ • Do the generator(s)have adequate capacity to operate the entire wastewater site? ❑ U 0 ❑ Is there an emergency agreement with a fuel vendor for extended run on back-up power? • ❑ ❑ 0 Is the generator fuel level monitored? i ❑ ❑ 0 Comment Generator will run the essential equipmemt for VWVfP The Generator is serviced twice/year by Electric Motor Services Generator load test is monitored by SCADA according to ORC Josh Obien Disinfection-Liquid Yes No NA NE Is there adequate reserve supply of disinfectant? • ❑ ❑ ❑ (Sodium Hypochlorite)Is pump feed system operational? © ❑ ❑ ❑ Page# 6 Permit: NC0079057 Owner-Facility: Manteo'. VTP Inspection Date: 01/29/2019 Inspection Type: Compliance Evaluation Disinfection-Liquid Yes No NA NE Is bulk storage tank containment area adequate'?(free of leaks/open drains) • ❑ ❑ ❑ Is the level of chlorine residual acceptable'? • ❑ 0 0 Is the contact chamber free of growth,or sludge buildup'? • ❑ ❑ ❑ Is there chlorine residual prior to de-chlorination? • ❑ 0 0 Comment. Facility uses 12.5% Sodium Hypochlorite Operations &Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping'? • ❑ 0 ❑ Does the facility analyze process control parameters,for ex MLSS, MCRT, Settleable 1111 ❑ ❑ ❑ j Solids, pH, DO,Sludge Judge,and other that are applicable'? 1)) Comment. O&M Manual was on site VWVfP was very well maintained Aeration Basins Yes No NA NE Mode of operation Type of-aeration system - - -- - -- --- - - Is-the-basin_free of dead spots?____ ____ ❑ ❑--I--❑ Are surface aerators and mixers operational'? _ 0 0 U ❑ Are the diffusers operational'? ❑ ❑ • ❑ Is the foam the proper color for the treatment process'? ❑ ❑ II 0 Does the foam cover less than 25%of the basin's surface'? ❑ ❑ IN ❑ Is the DO level acceptable'? ❑ ❑ I ❑ Is the DO level acceptable?(1 0 to 3 0 mg/I) ❑ ❑ • 0 Comment: Oxidation Ditch De-chlorination Yes No NA NE Type of system? Liquid Is the feed ratio proportional to chlorine amount(1 to 1)? • 0 0 ❑ Is storage appropriate for cylinders'? 0 0 III ❑ #Is de-chlorination substance stored away from chlorine containers'? • ❑ 0 ❑ Comment De- Chlorination/Facility uses Sodium Biosulfite. Are the tablets the proper size and type'? 0 0 • ❑ Are tablet de-chlorinators operational'? 0 0 • ❑ Number of tubes in use'? Page# 7 Permit: NC0079057 Owner-Facility: Manteo WWfP Inspection Date: 01/29/2019 Inspection Type: Compliance Evaluation De-chlorination Yes No NA NE Comment ji } } 1 { • Page# 8