Loading...
HomeMy WebLinkAboutNC0003468_Other Correspondence_20190115DUKE •�, ENERGY. January 15, 2019 Mr. Jeffrey Poupart, Section Chief NC Division of Water Resources 1617 Mail Service Center Raleigh, NC 27699-1617 RECEIVED/DENWDWR JA N 31 2019 Water Resources Permitting Section Subject: Dan River Combined Cycle Request for use of Chemicals in the Dewatering Treatment Process Amendment to existing NPDES permit renewal application NC0003468 Rockingham County Dear Mr. Poupart, Dan River Combined Cycle Duke Energy Carolinas 900 South Edgewood Road Eden, NC 27288 As requested and approved previously in our Dan River Combined Cycle Station Renewal Package dated July 2016, Duke Energy (Duke) submits this letter to amend our existing NPDES application under which the plant currently operates. The amendment is to disclose the use of hydrochloric acid for use for pH adjustment in the dewatering treatment system. An updated list of chemicals is attached. Please include this with the relevant permit files. Based on discussion, it is our understanding that with this modification to the existing permit application, no permit modification would be necessary and Duke is authorized to utilize these additives to assure compliance with NPDES permit limits and keep the dewatering system operational. If you have any questions regarding this letter, please contact Mrs. Joyce Dishmon at (336) 623-0238 or ioyce.dishmonCaduke-energycom. I certify under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations Sincerely, � Michael Lanning� GM II — Regulated Stations Dan River Combined Cycle Attachment Cc: Sherri Knight, W/S Regional Office, 450 W. Hanes Mill Rd, Suite 300, Winston-Salem, NC 27105 Joyce Dishmon/Filenet, Sr Env Specialist Dana Newcomb, Lead EHS Field Support Shannon Langley, Principle Form 2C — Item VI Potential Discharges Not Covered by Analysis Location Chemical Quantity Frequency Purpose Water treatment 60% Ferric 5000 gal tank As needed Coagulant (Clarifier) Sulfate/Ferralyte 8130 Water Treatment 25% Sodium 3000 gal tank As Needed pH control (Clarifier) Hydroxide Water Treatment 12.5% Sodium 6000 gal tank As Needed disinfection (Clarifier) Hypochlorite Water Treatment Nalclear 7768 400 gal tote As Needed Flocculant (Clarifier and Thickener Tank) Water Treatment Ferralyte 8130 5000 gal tank As Needed Flocculant (Clarifier and Thickener Tank) Water Treatment PolyClean 7 5 gal pails As Needed Polymer pump (Polymer Pumps) cleaning solution Cooling Tower 31) Trasar 3DT187 2000 gals tank As needed Dispersant/corrosion (shared with Chiller inhibitor Tower) Cooling Tower 12.5% Sodium 6000 gals tank As needed Disinfection/biological (shared with Chiller Hypochlorite growth control Tower) Cooling Tower Trasar 3DT199 110 gal tote As needed Corrosion inhibitor (shared with Chiller Tower) Cooling Tower Nalco 7468 5 gal pails As needed Defoamer Chiller System DOWFROST HD 63000 gals Circulated, Cooling Agent (propylene glycol) (system) closed system Chiller System Dupont SUVA 123 2000 gals Circulate, Refrigerant closed system Chiller System NalPrep IV 200 gals 1/year Layup Chemical Closed Cooling Water 33% Propylene 21000 gals As needed Cooling Agent Glycol (system) Closed Cooling Water Nalco C-4710 5 gal pail As needed Corrosion Inhibitor Demineralizer Bldg 38% Sodium 330 gal tote As needed Dechlorination (RO and Cooling Tower bisulfite Blow down) Demineralizer Bldg 25% Sodium 330 gal tote As needed pH control (RO system) hydroxide Demineralizer Bldg 50% Citric acid 350 gal tote As needed OF acid cleaning (UF system) Demineralizer Bldg (UF 12.5% sodium 330 gal tote As needed OF bleach cleaning system) hypochlorite Demineralizer Bldg AntiscalantPC- 110 gal tote As needed Corrosion inhibitor (RO system) 191T Demineralizer Bldg RoCide DB20 150 ml 1/quarter or as Biocide (RO cleaning biocide) needed Demineralizer Bldg RoClean P303 96 Ibs 1/quarter or as RO acid cleaning (RO cleaning) needed Demineralizer Bldg RoCide IS2 1/quarter or as Biocide (RO cleaning) needed Demineralizer Bldg RoClean P111 96 Ibs 1/quarter or as RO caustic cleaning (RO cleaning) needed Aux Boiler Bldg 19% Aqueous 330 gal tote As needed pH control (HRSG Water) Ammonia Aux Boiler Bldg Eliminox 75 gal tote As needed Oxygen scavenger (HRSG Water) Unit 9 HRSG phosphate Trisodium 300 gal tank As needed Corrosion Inhibitor skid phosphate (HRSG Water) Unit 8 HRSG phosphate Trisodium 300 gal tank As needed Corrosion Inhibitor skid phosphate (HRSG water) Steam Turbine Bldg 19% Aqueous 350 gal tote As needed pH control (HRSG Water) ammonia Selective Catalytic 19% Aqueous 20000 gal tank As needed NOx emissions Reduction ammonia reduction Treated Domestic Bio-sanitizer 135 Ibs As needed Disinfection/biological Sewage Tablets growth control (Calcium Hypochlorite) Ash Basin 25-50% Sodium 250 gal tote As needed pH control hydroxide Ash Basin Sulfuric Acid 250 gal tote As needed pH control Ash Basin Compressed CO2 Cylinders I As needed pH control Ash Basin Hydrochloric Acid 250 gal tote As needed pH control