Loading...
HomeMy WebLinkAboutNC0046728_Inspection_20190114NORTH CAROLINA DIVISION OF WATER RESOURCES PRETREATMENT COMPLIANCE INSPECTION (PCI) REPORT BACKGROUND INFORMATION: 1. Control Authority (POTW) Name: Town of Mooresville 2. Control Authority Representative(s): Jeff Campbell, Eric Brackett 3. Title(s): Environmental Compliance Supervisor, Environmental Compliance Officer 4. Last Inspection Date: 3/16/17 Inspection Type: ❑ PCI ® Audit 5. Has Program Completed All Requirements from the Previous Inspection and Program Info Sheet(s)? ® YES ❑ NO 6. Is POTW under an Order That Includes Pretreatment Conditions? ❑ YES ® NO Order Type, Number, Parameters: Are Milestone Dates Being Met? ❑ YES ❑ NO ® NA ICIS CODING Main Program Permit Number MM/DD/YY NCO046728 01/09/19 7. Current Number Of Significant Industrial Users (SIUs)? 1 3 8. Number of SIUs With No IUP, or With an Expired IUP? 0 9. Number of SIUs Not Inspected By POTW in the Last Calendar Year? 1 0 10. Number of SIUs Not Sampled By POTW in the Last Calendar Year? 0 11. Number of SIUs In SNC For Limits Violations During Either of the Last 2 Semi -Annual Periods 0 12. Number of SIUs in SNC For Reporting During Either of the Last 2 Semi -Annual Periods 0 13. Number of SIUs in SNC with Pretreatment Schedule? 0 14. Number of SIUs on Schedules? 0 15. Current Number of Categorical Industrial Users CIUs ? F 0 16. Number CIUs in SNC? 11 0 POTW INTERVIEW 17. Since the Last PCI, has the POTW had any NPDES Limits Violations? If Yes, What are the Parameters and How are these Problems Being Addressed? 18. Since the Last PCI, has the POTW had any Problems Related to an Industrial Discharge (Interference, Pass -Through, Blockage, Citizens' Complaints, Increased Sludge Production, Etc.)? If Yes, How are these Problems Being Addressed? 19. Which Industries have been in SNC for Limits or Reporting during N/A either of the Last 2 Semi -Annual Periods? Not Been Published for Not Pu Public Notice?(May refer to PAR if Excessive SIUs in SNC) 20. Which Industries are on Compliance Schedules or Orders? For all SIUs on an Order, Has a Signed Copy of the Order been sent to the Division? 21. Are Any Permits Or Civil Penalties Currently Under Adjudication? If Yes, Which Ones? ® YES ❑ NO; monthly average effluent fecal coliform violation in May 2017. ❑ YES ®NO )lished: N/A N/A ❑ YES ❑ NO LTMP/STMP FILE REVIEW: 22. Is LTMP/STMP Monitoring Being Conducted at Appropriate Locations and Frequencies? ® YES ❑ NO 23. Are Correct Detection Levels being used for all LTMP/STMP Monitoring? ® YES ❑ NO 24. Is LTMP/STMP Data Maintained in a Table or Equivalent? ® YES ❑ NO Is Table Adequate? ® YES ❑ NO 25. All LTMP/STMP effluent data reported on Discharge Monitoring Report? ® YES ❑ NO 26. If NO to 23 - 26, list violations: 27. Should any Pollutants of Concern be Eliminated from or Added to LTMP/STMP? ❑ YES ® NO If yes, which ones? Eliminated: Added: NC DWR Pretreatment Compliance Inspection (PCI) Form Updated 7/25/07 Page 1 28. PRETREATMENT PROGRAM ELEMENTS REVIEW: Program Element Last Submittal Received Date In file? Last Approval Date In file Date Next Due, If Applicable Headworks Analysis (HWA) 11/5/18 ® Yes ❑ No 1/14/14 ® Yes ❑ No In Review Industrial Waste Survey IWS 3/13/17 ® Yes ❑ No 1 5/23/17 ® Yes ❑ No 5/30/22 Sewer Use Ordinance SUO 1/2/13 ® Yes ❑ No 1/10/13 ® Yes ❑ No Enforcement Response Plan (ERP) 2/11/11 ® Yes ❑ No 3/29/11 ® Yes ❑ No Long Term Monitoring Plan (LTMP) 6/30/16 ® Yes ❑ No 9/20/16 ® Yes ❑ No INDUSTRIAL USER PERMIT (IUP) FILE REVIEW: 29. User Name = 1. Carolina Beverage Group 2. BestCo, Inc. 3. Niagra Bottling 30. IUP Number 0017 0006 F 0-018 31. Does File Contain Current Permit? ® Yes ❑ No ® Yes ❑ I ® Yes ❑ No 32. Permit Expiration Date 12/31/23 6/30/22 22/31/21 33. Categorical Standard Applied (I.E. 40 CFR, Etc.) Or N/A N/A N/A N/A 34. Does File Contain Permit Application Completed Within One Year Prior ® Yes ❑ No ® Yes ❑ No ® Yes ❑ No to Permit Issue Date? 35. Does File Contain an Inspection Completed Within Last Calendar Year? I ® Yes ❑ No ® Yes ❑ No ® Yes ❑ No 36. a. Does the File Contain aSlug/Spill Control Plan? a. EYes ❑No a. ®Yes ❑No a. ®Yes ❑No b. If No, is One Needed? See Inspection Form from POTW b. ❑Yes []No b. ❑Yes ❑No b. []Yes []No 37. For 40 CFR 413 and 433 TTO Certification, Does File Contain a Toxic ❑Yes❑NoNN/A ❑Yes❑NoNN/A ❑Yes❑NoNN/A Organic Management Plan (TOMP)? 38. a. Does File Contain Original Permit Review Letter from the Division? a. EYes ❑No a. EYes []No a. EYes ❑No b. All Issues Resolved? b.❑Yes❑No®N/A b.❑Yes❑No®N/A b.❑Yes❑No®N/A 39. During the Most Recent Semi -Annual Period, Did the POTW Complete ® Yes ❑ No ® Yes ❑ No ® Yes ❑ No its Sampling as Required by IUP, including flow? 40. Does File Contain POTW Sampling Chain -Of -Custody Forms? I ® Yes ❑ No ® Yes ❑ No ® Yes ❑ No 41a. During the Most Recent Semi -Annual Period, Did the SIU Complete its ®Yes❑No❑N/A ❑YesNNo❑N/A ❑YesNNo❑N/A Sampling as Required by IUP, including flow? 41b. During the Most Recent Semi -Annual Period, Did SIU submit all reports ®Yes❑No❑N/A ®Yes❑No❑N/A ®Yes❑No❑N/A on time? 42a. For categorical IUs with Combined Wastestream Formula (CWF), does ❑Yes❑NoEN/A ❑Yes❑NoNN/A ❑Yes❑NoEN/A file includeprocess/dilution flows as Required by IUP? 42b. For categorical IUs with Production based limits, does file include ❑Yes❑NoNN/A ❑Yes❑NoNN/A ❑Yes❑NoNN/A production rates and/or flows as Required by IUP? 43a. During the Most Recent Semi -Annual Period, Did the POTW Identify EYes❑No❑NA ❑Yes❑NoNN/A ❑Yes❑NoEN/A All Limits Non -Compliance from Both POTW and SIU Sampling? 43b. During the Most Recent Semi -Annual Period, Did the POTW Identify ❑Yes❑NoEN/A NYes❑No❑N/A ❑YesNNo❑N/A All Reporting Non -Compliance from SIU Sampling? 44. a. Was the POTW Notified by SIU (Within 24 Hours) of All Self- a.®Yes❑No❑N/A aaYes❑No❑N/A a.❑Yes❑No®N/A Monitoring Violations? b. Did Industry Resample and submit results to POTW Within 30 Days? b.❑Yes❑No®N/A b.®Yes❑No❑N/A b.❑Yes❑No®N/A c. Did POTW resample within 30 days of knowledge of SIU limit c.❑Yes❑No®N/A c.❑Yes❑No®N/A c.❑Yes❑No®N/A violations from the POTW sample event? 45. During the Most Recent Semi -Annual Period, Was the SIU in SNC? ❑ Yes ® No 11 ❑ Yes ® No ❑ Yes ® No 46. During the Most Recent Semi -Annual Period, Was Enforcement Taken EYes❑No❑N/A NYes❑No❑N/A ❑YesNNo❑N/A as Specified in the POTW's ERP (NOVs, Penalties, timing, etc.)? 47. Does the File Contain Penalty Assessment Notices? NYes❑No❑N/A ❑Yes❑NoNN/A ❑Yes❑NoNN/A 48. Does The File Contain Proof Of Penalty Collection? EYes❑No❑N/A ❑Yes❑NoNN/A ❑Yes❑NoEN/A 49. a. Does the File Contain Any Current Enforcement Orders? a.❑Yes❑No®N/A a.❑Yes❑No®N/A a.❑Yes ❑No®N/A b. Is SIU in Compliance with Order? b.❑Yes❑No®N/A b.❑Yes❑No®N/A b.❑Yes❑No®N/A 50. Did the POTW Representative Have Difficulty in Obtaining Any of This ❑ Yes ®No ❑ Yes ®No ❑Yes ® No Requested Information For You? NC DWR Pretreatment Compliance Inspection (PCI) Form Updated 7/25/07 Page 2 FILE REVIEW COMMENTS: 35. The POTW performed SIJ inspections on 3/7/18 (Carolina Beverage Group), 5/9/18 (BestCo), and 8/1/18 (Niagra). 39. The POTW's on -site lab performs analyses on conventional parameters. Pace Analytical Services, Inc. (LTMP analyses) and Prism Labs (low level mercury) have also been contracted to provide analytical support. 41a. Carolina Beverage Group and BestCo both contract Statesville Analytical, Inc. for analyses. Niagra contracts Pace Analytical Services, Inc. for analyses. Niagra completed all IUP monitoring except for aluminum (monitor only) during the second half of 2018. 46. The POTW issued a NOV to BestCo for the failure to monitor IUP parameters during the 31 quarter of 2018. Carolina Berverage Group was issued a NOV for a BOD permit limit violation in November 2018. No enforcement action per Division approved ERP was taken against Niagra for the aluminum monitoring violation during the second half of 2018. Note: The POTW has submitted a request to the PERCS Unit to drop Niagra as a SI J. SUMMARY AND COMMENTS: Records reviewed during the inspection were organized and well maintained. The POTW will submit a revised LTMP to update the TSS and cyanide detection levels. The POTW must ensure that the SIUs monitor all parameters according to their IUPs and proper enforcement (per Division approved ERP) is initiated for any monitoring/reporting violations. Overall, the POTW's Industrial Pretreatment Program was being properly implemented. NOD: ❑ YES ®NO NOV: ❑ YES ®NO QNCR: ❑ YES ®NO POTW Ratine: Satisfactory ® Marginal ❑ Unsatisfactory_ ❑ E�—"96DWCC3437 cuSigneddby: PCI COMPLETED BY: ... DATE: January 14, 2019 Wes Bell, Mooresville Regional Office DocuSigned by: �^ 1/14/2019 A14CC681AF27425... NC DWR Pretreatment Compliance Inspection (PCI) Form Updated 7/25/07 Page 3 ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Director Jeff Campbell Environmental Compliance Supervisor Town of Mooresville Post Office Box 878 Mooresville, North Carolina 28115 Dear Mr. Campbell: NORTH CAROLINA Environmental Quality 14 January 2019 Subject: Pretreatment Compliance Inspection Town of Mooresville NPDES Permit No. NCO046728 Iredell County Enclosed is a copy of the Pretreatment Compliance Inspection Report for the inspection of the Town of Mooresville's approved Industrial Pretreatment Program on January 9, 2019, by Mr. Wes Bell of this Office. The report should be self-explanatory; however, should you have any questions concerning this report, please do not hesitate to contact Mr. Bell at (704) 235-2192 or at wes.bell(c lacdenr.gov. Sincerely, DocuSigned by: A14CC681AF27425... W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ Enclosure: Inspection Report D Q � North Carolina Department of Environmental Quality I Division of Water Resources Mooresville Regional Office 1 610 East Center Avenue, Suite 301 1 Mooresville, North Carolina 28115 NORTH CAROLINA Da"MoM a enWmn�bl mwnq 704,663.1699