Loading...
HomeMy WebLinkAboutWQ0040542_Application (FTSE)_201901237774 77 1 Central Files- APS SVVP 12/21/2018 Permit Number WQ0040542 Permit Tracking Slip Program Category Status Project Type Non -discharge In review New Project Permit Type Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions A Individual Primary Reviewer Permit Contact Affiliation dean.hunkele - Coastal SWRulle Permitted Flow Facility Facility Name Major/Minor Region 2218 Barnett Avenue Sewer minor Wilmington Location Address County New Hanover Owner Owner Name Cape Fear Public Utility Authority Dates/Events Facility Contact Affiliation Owner Type Government - Municipal Owner Affiliation James R. Flechtner PE 235 Government Center Dr Wilmington NC 28403 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 12/21/2018 Regulated Activities Requested /Received Events Additional information requested Additional information received : PORT CITY CONSULTING ENGINEERS, PLLC 6216 STONEBRIDGE ROAD WILMINGTON, NORTH CAROLINA. 28409 (910) 599-1744 TO: Dean Hunkele NCDWQ 127 Cardinal Drive Wilmington, NC 28405 WE ARE SENDING YOU ❑ Shop Drawings D Copy of Letter E�En (OF MuHgkonAd DATE 1 2/2 1 / 1 $ JOB NO. ATTENTION PHONE # RE: 2218 Barnett Avenue Sewer Permit Submittal Public Sewer E Attached F-] Under separate cover ❑ Prints ❑Plans R samples [:1 Change order [:] Diskette R _ the following items: ❑ Specifications COPIES DATE NO. DESCRIPTION 1 Check for $480 each for application fee 2 One Original &one copy of: Fast Track Application and Flow Tracking Form 1 USGS Quad Sheet I Sewer Narrative 1 Copy of email from Christyn Fertenbaugh approving the variance request THESE ARE TRANSMITTED as checked below: F-1 copies for � For approval ❑Approved as submitted Resubmit approval copies for ❑ For your use El Approved as noted ❑Submit distribution ❑ As requested ❑Returned for corrections ❑Return corrected prints ❑ For review and comment ❑ R FOR BIDS DUE 20 ❑PRINTS RETURNED AFTER LOAN TO US REMARKS: RECEIVEDINCDENRDWR COPY TO: File D E C 2-1 1 2018 Operations Section Wiirnin cat- Regionai Office SIGNED: //Uj2-Ni, If enclosures are not as noted, kindly notify us at once.M.,1 20 18 State of North Carolina Department of Environmental Quality Division of Water Resources DWR 15A NCAC 02T .0300 —FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 &SUPPORTING DOCUMENTATION Application Number: w&G6 H 0 �ziox(to be completed by DWx) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Cape Fear Public Utility Authority (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility Federal State/Coup Municipal ® OtherAO�Vk �o ❑ ❑ State/County ❑ p i 3. Signature authority's name: Matthew Tribett, PE per 15A NCAC 02T .0106�b) Title: Engineering Manager 4. Applicant's mailing address: 235 Government Center Drive City: Wih-n on State: NC Zip: 28403- t� > L, 5. Applicant's contact information:';>� )` SEC 212018Phone number: 910 332-6415 Email Address: matthew.tribett c ua.or , II. PROJECT INFORMATION: 1. Project name: 2218 Barnett Avenue 2. Application/Project status: Z Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: New Hanover 4. Approximate Coordinates (Decimal Degrees): Latitude: 34.23' Longitude:-77.92' 5. Parcel ID (if applicable): R05407-024-023-000 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Mark N. Hggoove License Number: 019742 Firm: Port City Consulting Engineers, PLLC Mailing address: 6216 Stonebridge Road City: Wilmington State: NC Zip: 28409- Phone number: (910) 599-1744 Email Address: mhargrove@ec.rr.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: James A. McLaughlin NSWWTF Permit Number: NC 0023965 Owner Name: Cape Fear Public Utility Authority V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Numbers . W O Q *fu V A 8A CLAP. System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): CFPUA FORM: FTA 04-16 Page 1 of 5 V1. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes [:]No []N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? El Yes ❑No ZN/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: HOA) been attached? ❑ Yes [-]No EIN/A 4. Origin of wastewater: (check all that apply): Z Residential Owned ❑Retail (stores, centers, malls) ❑ Car Wash D Residential Leased ❑Retail with food preparation/service ❑Hotel and/or Motels ❑ School /preschool /day care ❑Medical /dental /veterinary facilities ❑Swimming Pool /Clubhouse ❑ Food and drink facilities ❑Church ❑Swimming Pool/Filter Backwash ❑ Businesses /offices /factories ❑Nursing Home ❑Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic/Commercial % Commercial % Industrial (See 15A NCAC 02T .0103 (20)) Is there a Pretreatment Program in effect? ❑ Yes ® No 6. Has a flow reduction been approved under 15A NCAC 02T .0114(f)? ❑ Yes No ➢ If yes,, provide a copy of flow reductioapproval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow a'b No. of Units Flow Dwelling Unit 360 gal/day 1 360 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 360 GPD a See 15A NCAC 02T .0114(b)(d)(e)(1) and e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 360 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 6 20 DIP ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIH. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC(Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: 0Longitude: - ° 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .03 05(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B).* ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .03 05 (h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 Ix. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T.0305(f)): 1. Does the project comply with all separations found in 15A NCAC 02T .0305(f) & (g.) ➢ 15A NCAC 02T.0305(f) contains minimum senarations that shall be provided for sewer systems_ Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet "Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet "Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item IX.2) 50 feet "Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimmingpools 10 feet Final earth grade (vertical) 36 inches ➢ 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage ➢ If noncompliance with 02T.0305(f) or g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) Yes [:]No ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with all setbacks found in the river basin rules per 15A NCAC 02B .0200? Yes ❑ No ➢ This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project comply with an individual 404 Permit or any 401 Certifications? E Yes ❑ No ➢ Wetland -related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes 0 No ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting. of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest versionZ as applicable? 0 Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval o_ the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: 19 tAek ek. A) I �k r (Professional Engineer `r ov `e name from Application Item III.1.) attest that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. .....................................................................................y i North Carolina Professional Engineer's seal, signature, and date: 19742 GI N EEC % ................................ ................................... 3. Applicant's Certification per 15A NCAC 02T .0106(b): attest that this application for (Signature Authority's name title from `Application Item I.3.) QN has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: � Date: FORM: FTA 04-16 Page 5 of 5 �} fi i- ' �r t+. .� tt of �• k. E Division of Water Re-soulrces State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: H & L Mag, LLC Project Name for which flow is being requested: 2218 Barnett Avenue More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: James A. Loughlin (Northside) WWTP b. WWTP Facility Permit #: NPDES NC 0023965 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All f Zows are in MGD 16.000 2.690 10.661 0.0003 60 13.351 83.4% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: Pump Pump Station Station (Name or Permit Number) No. 10 N/A (A) (B) Design Average Approx. Firm Daily Flow** Current Capacity, * (Firm / pf), Avg. Daily MGD MGD Flow, MGD 14 RII? 5 91111 1.47? (C) (D)=(B+C) (E)=(A-D) Obligated, Not Yet Total Current Tributary Flow Plus Daily Flow, Obligated Available MGD Flow Capacity*** n IIR? 11 R 54 7_ 079 The Firm Capacity (design flow) of any pump station is defined as the maximum pumpea now that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Cape Fear Public Utility Authority Downstream Permit Number: Not Available Page 1 of 6 FTSE 10-18 III. Certification Statement: I Matthew Tribett, CFPUA Eng. Mgr certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. / � / S-// 2) Signing Official Signature Date C LW Title of Signing Official ` Page 2of6 FTSE 10-18 SEWER NARRATIVE 2218 BARNETT AVENUE SEWER DESCRIPTION The proposed sewer extension if to extend the existing 6" sewer main to serve one lot that currently does not have gravity sewer available in Wilmington, NC. Only 20 if of main is required such that a service can be extended over to the vacant lot located at 2218 Barnett Avenue in Wilmington, NC. _ R MICHAEU R. Secretary LINDA CULPEPPE Direaor I December 17, 2018 Matthew Tribett., P.E.., Engineering Manager Cape Fear Public Utility Authority 235 Government Center Drive Wilmington, NC 28403 Subject: Variance Request Approval 2218 Barnett Avenue Cape Fear Public Utility Authority (WQCS00012) New Hanover County Dear Mr. Tribett: The Division of Water Resources (Division) has reviewed the submitted variance request as received on November 61 2018 for the subject project. The Division will grant the variance request for the installation of approximately 20 linear feet of 6-inch public gravity sewer to extend the existing sewer to serve an undeveloped lot at 2218 Barnett Avenue in lieu of the minimum of 8-inch as required for public gravity sewer lines per 15A NC4CO2T.0305(i)(1),, in accordance with the provisions for alternative design under 15A NC4CO2T.0105(n). - Regardless of the variance approval,, in the event that the wastewater collection facilities fall to perform satisfactorily, including the creation of nuisance conditions.. the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. All other elements of this project shall be constructed in accordance with all applicable rules and statues including, 15A NCAC 2T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12,. 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1,, 2000 as applicable. Approval of the variance request does not constitute approval of the permit. If you need additional information concerning, this matter, please contact Christyn Fertenbaugh at (919) 707-3625 or via e-mail at Christ yn. Fertenbaug,h,@.ncdenr.g:0 Sitt,erely, X. V X-1 for Linda Culpepper Director., Division of Water Resources by Deborah Gore, Supervisor Pretreatment, Emergency Response, Collection System Unit cc: Mark N. Hargrove,, P.E.., Port City Consulting Engineers, PLLC (.M.har9r*ove,0a:ec.rr.coM.) Wilmington Regional Office., Water Quality Section Regional Operations Water Resources Central Files: WQCS00012 PERCS, (electronic copy) .................... North Carolina Department of Environmental Quality I Division of Water Resources 512 No-li Salisbury Street 11617 Mail Service Center I Raleigh, North Carolina 27699-1617 919.707.9000