Loading...
HomeMy WebLinkAboutNC0000639_Compliance Evaluation Inspection_20190114 t+" Yci 4.0 NORTH CAROLINA ROY COOPER Environmental Quality Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Director January 14, 2019 Mr. Henry Needham Sapona Manufacturing Company P.O. Box 2464 Asheboro, NC 27204 SUBJECT: Compliance Evaluation Inspection Sapona Manufacturing Company WWTP NPDES Permit No. NC0000639 Randolph County Dear Mr. Needham: On January 10, 2019, Jenny Graznak and Kelli Park of this office, met with Arnold Allred, Operator in Responsible Charge (ORC), and Joe Walsh, Back Up ORC, to perform a Compliance Evaluation Inspection at the Sapona Manufacturing Company wastewater treatment plant. This type of inspection consists of two basic parts: an in-office file review and an on-site inspection of the treatment facility. The attached EPA inspection form details the areas that were evaluated during this inspection. Some pertinent findings from the inspection are described in the inspection summary. The inspection found the facility to be satisfactory. If you have any questions regarding the inspection • or this report, please contact Jenny Graznak or me at(336) 776-9800. Sincerely, p-Sherri V. Knight, P.E. Regional Supervisor Water Quality Regional Operations Division of Water Resources Attachments: EPA Water Compliance Inspection Report cc: Central Files WSRO L_NPDES Unit D_EC North Carolina Department of Environmental Quality I Division of Water Resources Winston-Salem Regional Office 1450 W.Hanes Mill Road,Suite 300 I Winston-Salem,North Carolina 27105 336-776-9800 United States Environmental Protection Agency Form Approved. EPA Washington,D C 20460 OMB No.2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A-National Data System Coding(i e.,PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN I 2 [ I 3 I NC0000639 111 121 19/01/10 117 18 I�. 19► G 20I 211 I-�I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I P6 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA Reserved 67 I I 70 I I 711 I 72 11....1 I 73I I 174 75IJ I I I I I I 180 Section B Facility. Data Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 11 30AM 19/01/10 17/01/01 Sapona Manufacturing Company Exit Time/Date Permit Expiration Date 2478 Cedar Falls Rd 12 30PM 19/01/10 21/09/30 Cedar Falls NC 27230 Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /// Arnold Eugene Allred/ORC/336-824-6440/ Joseph Michael Walsh/ORC/336-736-7180/ Name,Address of Responsible Official/Title/Phone and Fax Number Contacted Arnold Eugene Allred,3309 Walker Store Rd Franklinville NC No 272488375/1336-672-0892/ Section C Areas Evaluated Dunng Inspection(Check only those areas evaluated) Permit El Flow Measurement Operations&Maintenance Records/Reports Self-Monitoring Program II Sludge Handling Disposal IN Facility Site Review Effluent/Receiving Waters Section D Summary of Finding/Comments(Attach additional sheetsiof narrative and checklists as necessary) (See attachment summary) ' Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date Jennifer F Graznak szVc2sriWSRO WQ//336-771-5000/ i A 9!?'Ci 9 Signature of M gemen Reviewer Agency/Office/Phone and Fax Numbers Date I(ICI('9 EPA Form 35 (Rev 9-94)Previous editions are obsolete Page# 1 NPDES yr/mo/day Inspection Type 1 31 NC0000639 111 121 19/01/10 117 18 i i Section D Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) The inspection found the facility to be satisfactory. Please note that the facility exceeded the daily maximum limit for Total Suspended Solids in April 2018, and therefore received a Notice of Deficiency from DEQ.All parameters appear to have been sampled according to the permit requirements. • • • - Page# 2 Permit: NC0000639 Owner-Facility: Sapona Manufacturing Company Inspection Date: 01/10/2019 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new 0 0 • 0 application'? Is the facility as described in the permit'? 0 • ❑ ❑ #Are there any special conditions for the permit'? ❑ • ❑ ❑ • Is access to the plant site restricted to the general public? • 0 ❑ ❑ Is the inspector granted access to all areas for inspection'? • ❑ 0 ❑ Comment. The permit cover sheet does not include the sludge holding tank or the equalization tank with grinder pumps. These need to be added to the components list durinq the next permit renewal process. Outfall 002 only discharges when the air conditioning is used durinq the summer months. Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping'? • ❑ ❑ ❑ Does the facility analyze process control parameters,for ex MLSS, MCRT, Settleable • ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable'? Comment: Sapona does all of their own maintenance on the system.After the influent pump station,the entire system is gravity flow. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit'? • ❑ ❑ ❑ Is all required information readily available, complete and current? • ❑ ❑ ❑ Are all records maintained for 3 years(lab. reg. required 5 years)' ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? • ❑ ❑ ❑ Is the chain-of-custody complete'? • ❑ ❑ ❑ Dates,times and location of sampling III Name of individual performing the sampling • Results of analysis and calibration U Dates of analysis • Name of person performing analyses • Transported COCs • Are DMRs complete do they include all permit parameters'? • ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ • ❑ (If the facility is=or>5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ I ❑ on each shift'? Is the ORC visitation log available and current'? • ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification'? • ❑ ❑ ❑ Page# 3 Permit: NC0000639 Owner-Facility: Sapona Manufacturing Company Inspection Date: 01/10/2019 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Is the backup operator certified at one grade less or greater than the facility classification'? • ❑ ❑ ❑ • Is a copy of the current NPDES permit available on site'? • ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ❑ ❑ II ❑ Comment Mr.Allred performs pH, chlorine, and temperature using field parameter certification#5408. Envirolink and Meritech analyze all other parameters for the facility. Bar Screens Yes No NA NE Type of bar screen a Manual b Mechanical ❑ Are the bars adequately screening debris'? • ❑ ❑ ❑ Is the screen free of excessive debris'? MI ❑ ❑ ❑ Is disposal of screening in compliance'? • ❑ ❑ ❑ Is the unit in good condition'? • ❑ ❑ ❑ Comment: Flow Measurement-Effluent Yes No NA NE #Is flow meter used for reporting'? ❑ IIII ❑ ❑ Is flow meter calibrated annually'? ❑ ❑ • ❑ Is the flow meter operational'? ❑ ELM ❑ (If units are separated) Does the chart recorder match the flow meter'? ❑ ❑ • ❑ Comment The permit requires an instantaneous weekly flow measurement. Influent flow is estimated by the operators.There is an effluent flow meter, but it is not used for reporting purposes because it is set up in the treatment set-up prior to the chllorine contact and is only used for process control purposes Aeration Basins Yes No NA NE Mode of operation Ext.Air Type of aeration system Diffused Is the basin free of dead spots'? ❑ ❑ ❑ Are surface aerators and mixers operational'? ❑ ❑ • ❑ Are the diffusers operational'? • ❑ ❑ ❑ Is the foam the proper color for the treatment process'? • ❑ ❑ ❑ Does the foam cover less than 25%of the basin's surface'? • ❑ ❑ ❑ Is the DO level acceptable'? ❑ ❑ ❑ Page# 4 AP Permit: NC0000639 Owner-Facility: Sapona Manufacturing Company Inspection Date: 01/10/2019 Inspection Type: Compliance Evaluation Aeration Basins Yes No NA NE Is the DO level acceptable?(1.0 to 3.0 mg/I) 0 0 0 • Comment. Secondary Clarifier Yes No NA NE ' Is the clarifier free of black and odorous wastewater? • 0 0 0 Is the site free of excessive buildup of solids in center well of circular clarifier? 0 0 • 0 Are weirs level? • 0 0 0 Is the site free of weir blockage? • 0 0 0 Is the site free of evidence of short-circuiting? • 0 0 0 Is scum removal adequate? • 0 0 0 Is the site free of excessive floating sludge? • 0 0 0 Is the drive unit operational? • 0 0 0 Is the return rate acceptable(low turbulence)? II 0 0 0 Is the overflow clear of excessive solids/pin floc? • 0 0 ❑ Is the sludge blanket level acceptable?(Approximately'/4 of the sidewall depth) ❑ 0 0 • Comment: Disinfection-Liquid Yes No NA NE Is there adequate reserve supply of disinfectant? IN 0 0 0 (Sodium Hypochlorite) Is pump feed system operational? _ • 0 0 0 Is bulk storage tank containment area adequate?(free of leaks/open drains) • 0 0 0 Is the level of chlorine residual acceptable? 0 0 0 • Is the contact chamber free of growth, or sludge buildup? • 0 0 0 Is there chlorine residual prior to de-chlorination? 0 0 0 IN Comment. Liquid hypochlorite is now added immediately after the clarifier to allow for extra chlorine contact time.The liquid is added via timer. De-chlorination Yes No NA NE Type of system? Liquid Is the feed ratio proportional to chlorine amount(1 to 1)? 0 0 0 • Is storage appropriate for cylinders? 0 0 III 0 #Is de-chlorination substance stored away from chlorine containers? IN 0 0 0 Are the tablets the proper size and type? 0 0 0 Page# 5 Permit: NC0000639 Owner-Facility: Sapona Manufacturing Company Inspection Date: 01/10/2019 Inspection Type: Compliance Evaluation De-chlorination Yes No NA NE Comment: Liquid calcium thiosulfate is added at the end of the chlorine contact chamber. Are tablet de-chlorinators operational? ❑ ❑ ❑ II Number of tubes in use'? Comment: - Aerobic Digester Yes No NA NE Is the capacity adequate'? ❑ ❑ • ❑ Is the mixing adequate'? ❑ ❑ • ❑ Is the site free of excessive foaming in the tank'? MI ❑ ❑ ❑ #Is the odor acceptable'? • ❑ ❑ ❑ #Is tankage available for properly waste sludge'? • ❑ ❑ ❑ Comment* Sludge from the bottom of the clarifier is pumped into a sludge holding tank on a daily basis. The solids are removed from the tank as necessary by Kivett and Sons Septic Tank Service for disposal in•the Franklinville WWTP (this typically occurs once per month and is tracked on the daily logs). Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ MI ❑ Is sample collected below all treatment units' ❑ ❑ ❑ Is proper volume collected'? • ❑ ❑ ❑ Is the tubing clean'? ❑ ❑ 11 ❑ #Is proper temperature set for sample storage(kept at less than or equal to 6 0 degrees ❑ ❑ ❑ • Celsius)? Is the facility sampling performed as required by the permit(frequency,sampling type IM ❑ ❑ ❑ representative)' Comment: Grab samples are collected from the effluent trough. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained'? ❑ ❑ • ❑ Are the receiving water free of foam other than trace amounts and other debris'? • ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly'? ❑ ❑ U ❑ Comment The effluent pipe is under water in the Deep River and cannot be seen. Page# 6