Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0040528_Application (FTSE)_20190115
Central Files. APS SWP 12/13/2018 Permit Number WQ004O528 Permit Tracking Slip Program Category Status Project Type Non -discharge In review New Project Permit Type Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions A Individual Primary Reviewer Permit Contact Affiliation dean.hunkele Coastal SWRule Permitted Flow Facility Facility Flame Major/Minor Region Leach Street Pump Station Capacity Expansion Minor Wilmington Location Address County 38 Leach St Columbus Facility Contact Affiliation Brunswick NC 28424 Owner Owner Name Owner Type Town of Brunswick Government - Municipal Owner Affiliation Nancy Hill PO Box 68 Dates/Events Brunswick NC 28424006 THE INC. ..."" . .. .f.v.:G� :.I� 'Y�s:� ` •! _; .".._"." � ._ Lsrtc:t»»�� Ws �z CW' " r.n: :...f.��.' _. Il:.i...:_.� ENGINEERING AND DESIGN 708 Abner Phillips Road Warsaw, NC 28398 Phone (910) 293-2770 Fax (9.10) 293-2766 Firm License No. C-4438 December 11, 2018 Dean Hunkele NCDEQ-Dept. of Water Quality Wilmington Regional Office 127 Cardinal Dr. Ext. Wilmington, NC 28405 Ref: Town of Brunswick Sewer Force Main Permit Application Dear Dean, Please find all necessary documents for the application of Sewer Permit for a force main replacement for the Town of Brunswick. This application will consist of the construction of 5,220 linear feet of 6" Force Main along Hwy. 130 that will dump into the existing manhole that belongs to the City of Whiteville. There is. no additional flow to be permitted. Enclosed please find 2 copies of the following: Fast -Track Application Narrative Flow Tracking Forms Waste. Flow Map to the Whiteville Water Reclamation Facility USES Topo Map - TDH Calculation for proposed force main and pump curve. - Check for $480.00 Please do not hesitate to call me at 910-293 -2770 if you have any questions. cerel , Bob Mitchell The Adams Company, Inc. Encl. State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 —FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 &SUPPORTING DOCUMENTATION Application Number. W6(yJ 1?6,�*! (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Town of Brunswick (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County Z Municipal ❑ Other 3. Signature authority's name: Nancy Hill per 15A NCAC 02T .0106(b) Title: Mayor r.. t' F,c , 4. Applicant's mailingaddress: P.O. Box 68 � �- ,! �a g City: Brunswick State: NC Zip: 28424- DEC 13 r A 5. Applicant's contact information: spy �� a {,r.., L�•i Phone number: (910) 642-6741 Email Address: tobrunswickgcenturylink. net II. PROJECT INFORMATION: 1. Project name: T : ,. 9*tensiatt ,, � �, , . ,1..�..�.� --- -Main)— 2. Application/Project status: Z Proposed (New Permit) [:] Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Columbus 4. Approximate Coordinates (Decimal Degrees): Latitude: 34.2939' Longitude:-78.70590 5. Parcel ID (if applicable): 003773 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: M. Floyd Adams License Number: 12273 Firm: The Adams Company Inc Mailing address: 708 Abner Phillips Rd. City: Warsaw State: NC Zip: 28398- Phone number: (910) 293-2770 Email Address: mfadamsl223(kgmail.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Whiteville Water Reclamation Facility Permit Number: NC 0021920 Owner Name: City of Whiteville V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ0034221 Downstream (Receiving) Sewer Size: 8 inch System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): Town of Brunswick FORM: FTA 04-16 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? [:]Yes [:]No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes [:]No ®N/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: HOA) been attached? El Yes E]No ®N/A 4. Origin of wastewater: (check all that apply): E Residential Owned E Retail (stores, centers, malls) El Car Wash ® Residential Leased ® Retail with food preparation/service ❑ Hotel and/or Motels ® School / preschool / day care ® Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church El Swimming Pool/Filter Backwash ® Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic/Commercial % Commercial % Industrial (See 15A NCAC 02T .0103(20)) Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(f1? ❑ Yes ® No ➢ If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow a,b No. of Units Flow gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total GPD a See 15A NCAC 02T .0114(b), (d), (e)(1) and(e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ® Rehabilitation or replacement of existing sewer with no new flow expected ® Other (Explain): Upsizing existing force main line from 4" to 6" FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: Leach Street 2. Approximate Coordinates (Decimal Degrees): Latitude: 34.29390 Longitude:-78.70590 3. Design flow of the pump station: 0.374 millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): 260 gallons per minute at 73 feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6 5220 PVC 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): Z Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B)_ ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T.0305(f)): 1. Does the project comply with all separations found in 15A NCAC 02T.0305(f) & (g) ➢ 15A NCAC 02T.0305(f) contains minimum separations that shall he nrovided for sewer systems: ❑ Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet "Waters Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305ffl cannot be achieved. ➢ "Stream Stream classifications can be identified using the Division's NC Surface Water Classifications webpage ➢ If noncompliance with 02T.0305(f) or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes [:]No ❑ N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No ❑ N/A ➢ This would include Trout Buffered Streams per 15A NCAC 213.0202 4. Does the project require coverage/authorization under a 404 Nationwide or E]Yes ® No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? Z Yes [:]No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes Z No ❑ N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? N Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting dne»mPntc 2. Professional Engineer's Certification: Flo (Pr e 6.4 AOL �-nx E ssional Engineer's name from Application Item III.1.) attest that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): (Sig Authority's name &title from Application Item 1.3.) attest that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: 7 Date: /VIC IQ FORM: FTA 04-16 Page 5 of 5 TOWN OF BRUNSWICK 2016-I CDBG LEACH ST. FORCE MAIN REPLACEMENT Brunswick, NC Columbus County 12/03/18 NARRATIVE 1. Project Title: Brunswick Sewer Line Extension 2016-I (Leach Force Main) 2. Location: Hwy 130, Brunswick, NC 3. Waste Water Treatment Facility — City of Whiteville, NC (NC 0021920) 4. Additions/Improvements : Replace existing 4" Force Main with 6" Force Main along Hwy 130 from Leach St. to the City of Whiteville manhole. Over 80% of the new line will be installed using directional bore. 5. Future service potential — Currently the Leach St. force main can only pump 108 gpm due to the restriction of approximately a mile of 4" force main. The proposed 6" force main will be able to accommodate an additional 152 gpm or up to 87,000 additional gallons per day. The current flow is approximately 29,000 gpd. 6. The proposed 6" force main from Leach Street will be laid in the NCDOT ROW will be owned and operated by the Town of Brunswick. 7. This area is located in the Waccamaw River watershed. 8. No Historic Sites are a part of this project. 9. None of the proposed facilities will be located in the 100 year flood zone. 10. None of the open cut proposed facilities will be located in wetlands. Hunkele, Dean From: Bob Mitchell <bobmitch58@gmail.com> Sent: Thursday, December 13, 2018 4:03 PM To: Hunkele, Dean Subject: [External] RE: Leach St PS capacity increase - pending WQ0040528 The pumps are not changing, 10.5 HOMA. We are upsizing the force main from a 4" to a 6" PVC. The TDH will drop from about 90 to 73. The current actual rate (from draw down test) is 108 gpm. Bob From: Hunkele, Dean[mailto:dean.hunkele@ncdenr.gov] Sent: Thursday, December 13, 2018 3:36 PM To: mfadams1223@gmail.com; Bob Mitchell (bobmitch58@gmaii.com) Subject: Leach St PS capacity increase - pending WQ0040528 Importance: High What is its current pumping capacity that is being increased to 260-gom with this project? Dean Hunkele Environmental Specialist II Water Quality Regional Operations Section Division of Water Resources Department of Environmental Quality 910.796.7215 Reception Desk 910.796.7380 Direct 910.350.2004 Fax Dean.Hunkele ncdenr. ov Wilmington Regional Office 127 Cardinal Drive Ext Wilmington, NC 28405 http:/Zdeg.nc.gov/contactZregional-offices/wilmington r s ^c d a � } 4 this � } d^ 5 = y '3 � �F � .f"e �`� L � S^ � y :°`. i'�� i +'„ rya �. y� r" � � i c � ,:r disclosed f ^t ^^e S .�,i€ ^ "e t" � t A row t?f � � ublje t �'o he N 3rth �. a li o P ubli , R � �f `s t of/ on � "� ly b i.�c se to third a.. 3.,.r s a,. i.., r r 3,.: h.8 r s E.r g...Y rya rLe The goal of the Fast Track sewer permit program is to issue a permit in no more than 30 business days from receipt of a complete application and if no additional information has to be requested upon full review. Please use the Department's Permit Application Tracker to determine the official application receipt date to allow you to estimate a date for issuance and find the reviewer's name. Once issued, the record stays on the site for 30 days. For previously issued sewer permit info or to check on sewer certification receipt status, please use the Division's Sewer Extension Permit Tracker. Using the Issue Date on top of the Engineer Certification Form is best way to ensure getting what you want especially for multi -version permits; using today's date only gives info on the latest permit version. Confirmation using this method will replace letters and emails; it is recommended that confirmation be printed and/or saved. 2olG Sr"os"tick Seftiay. 5...r��s Whitieville WWTF, NC -- FLOW MAP 9--Zq-18 tBaldwin Cie 01 B 1 7 74 6 _... O S us 1*//1 -- ii Bus Runnymeade 74 Bus Sunset Terrace 76 Vg 74 ' Bus Bus Z 74 76 r r. �. C5. Cn E �,alhouu at N6 44, Pay $t .-�.........�. WW �,� 701 C-1955 , -1-43 �, sx' :Bus Mill St � �.1.. S • �.. 130 7 Smith 411 -: T.�► '� Crossing, lit L,�t S �. Yka x >• ' , 0 ,\S.. c y h Whiteville 5Z.1irIke %4L 0; Log Rd: Rd -z "'t.. q A lit ON �;...174 130 40 .3Prunswick 701 IV 016 Copyright © and (P) 1988-2008 Microsoft Corporation and/or its suppliers All rights reserved http://www.microsoft.com/streets/ U ml 0.5 1 1.5 2 2.5 Certain mapping and direction data © 2008 NAVTEQ All rights reserved. The Data for areas of Canada includes information taken with permission from Canadian authorities. including © Her Majesty the Queen in Right of Canada, © Queen's Printer for Ontario. NAVTEQ and NAVTEQ ON BOARD are trademarks of NAVTEQ © 2008 Tele Atlas North America, Inc. All rights reserved Tele Atlas and Tele Atlas North America are trademarks of Tele Atlas, Inc. O 2008 by Applied Geographic Systems All rights reserved