Loading...
HomeMy WebLinkAboutNC0023736_Lenoir Pretreatment PCI_20190115 (4)DocuSign Envelope ID: 4F1ADC05-2FCB-4C37-AD58-EBECE3187F8C ROY COOPER (:&wOrnor K41C-IAEL S. R.EGAN Secrerary LINDA CULPEPPER Directar Alisa Triplett City of Lenoir PO Box 958 Lenoir, NC 28645-0958 NORTH CAROLINA Environmental Quad" January 14, 2019 SUBJECT: Pretreatment Compliance Inspection Report Gunpowder Creek WWTP NPDES WW Permit No. NCO023736 Caldwell County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Gunpowder Creek WWTP on 1/09/2019. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0023736. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". The following items were noted during the inspection: The same individual is currently serving as the WWTP Superintendent, Lab Manager and Pretreatment Coordinator. This is a large and diverse workload for a single person. Consider appointing the Pretreatment Coordinator as a new and distinct position from the other roles currently being performed by the WWTP Superintendent. • Excela has been identified as an IU in the most recent IWS. The Long Form has been completed and submitted to PERCS, and they have been identified as a CIU. Continue to coordinate with PERCS to develop an IUP for Excela and begin regulating/inspecting/sampling them accordingly. N"NCarokisDepartment ofEnvironmentalQaslay I OivisionofWater Resourres Ashevil ie Regional Off. 2090 U.S_ 70 ftimay I Sw nanoa, North Carolaa 23773 Q 32S 29C-0500 DocuSign Envelope ID: 4F1ADC05-2FCB-4C37-AD58-EBECE3187F8C If you should have any questions, please do not hesitate to contact Timothy Heim with the Water Quality Regional Operations Section in the Asheville Regional Office at 828-296-4500 or via email at tim.heim@ncdenr.gov. Sincerely, DocuSigned by: 7E617 38285848C... G. Landon Davidson, P.G., Regional Supervisor Water Quality Regional Operations Section Asheville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Cc: WQS Asheville Regional Office - Enforcement File NPDES Compliance/Enforcement Unit - Enforcement File G:\WR\WQ\Caldwell\Wastewater\Municipal\Gunpowder Creek 23736\Pretreatment\2019 PCI\20190114_NC0023736_PCI Ltr.Docx N"NCaroiinsDepartmentofEnvironmentalQuality I OivistnofWaterResources Ashevil ie Regnnal Office 2090 U.S_ 70 }f� imay I Sw nsnoa, North CamZL 23773 Q 32S 29C-0500 DocuSign Envelope ID: 4F1ADC05-2FCB-4C37-AD58-EBECE3187F8C NORTH CAROLINA DIVISION OF WATER RESOURCES PRETREATMENT COMPLIANCE INSPECTION (PCI) REPORT BACKGROUND INFORMATION [Complete Prior To PCI; Review Program Info Database Sheet(s)l I. Control Authority (POTW) Name: _City of Lenoir 2. Control Authority Representative(s): Alisa Triplett 3. Title(s): WWTP Supervisor, Lab Manager, Pretreatment Coordinator 4. Last Inspection Date: _7/30/14 Inspection Type (Check One): x PCI ❑ Audit 5. Has Program Completed All Requirements from the Previous Inspection and Program Info Sheet(s)? x YES ❑ NO 6. Is POTW under an Order That Includes Pretreatment Conditions? ❑ YES x NO Order Type, Number, Parameters: —NA PCS CODING Trans.Code Main Program Permit Number I—N-J I NICIO 10 12 131918 111 Are Milestone Dates Being Met? ❑ YES ❑ NO MM/DD/YY Inspec.Type 1 01 111 1 19 1 L P (DTIA) (TYPI) Inspector Fac. Type L —SJ LLJ (INSP) (FACC) 7. Current Number Of Significant Industrial Users (SIUs)? 4 SILTS 8. Current Number Of Categorical Industrial Users (CIUs)? 1 CIUS 9. Number of SIUs Not Inspected By POTW in the Last Calendar Year? 1 10. Number of SIUs Not Sampled By POTW in the Last Calendar Year? 1 11. Enter the Higher Number of 9 or 10 1 NOIN 12. Number of SIUs With No IUP, or With an Expired IUP 0 NOCM 13. Number of SIUs in SNC for Either Reporting or Limits Violations During Either of the Last 2 Semi -Annual Periods Total Number of SIUs in SNC 0 PSNC 14. Number of SIUs in SNC For Reporting During Either of the Last 2 Semi -Annual Periods 3 MSNC 15. Number of SIUs In SNC For Limits Violations DuringEither of the Last 2 Semi -Annual Periods 2 JkSNPS 16. Number of SIUs In SNC For Both Reporting and Limits Violations During Either of the Last 2 Semi-annual Periods 0 POTW INTERVIEW 17. Since the Last PCI, has the POTW had any NPDES Limits Violations? If Yes, What are the Parameters and How are these Problems Being Addressed? 18. Since the Last PCI, has the POTW had any Problems Related to an Industrial Discharge (Interference, Pass -Through, Blockage, Citizens' Complaints, Increased Sludge Production, Etc.)? If Yes, How are these Problems Being Addressed? 19. Which Industries have been in SNC for Limits or Reporting during SNC for either of the Last 2 Semi -Annual Periods? Not Been Published for SNC for Public Notice?(May refer to PAR if Excessive SIUs in SNC) Not Pul 20. Which Industries are on Compliance Schedules or Orders? For all SIUs on an Order, Has a Signed Copy of the Order been sent to the Division? 21. Are Any Permits Or Civil Penalties Currently Under Adjudication? If Yes, Which Ones? ❑ YES ®NO ❑ YES ®NO Limits: 1 — Beocare: Chromium Reporting:0 dished: Public Notice Published None. ❑ YES x NO LTMP/STMP FILE REVIEW: 22. Is LTMP/STMP Monitoring Being Conducted at Appropriate Locations and Frequencies? x YES ❑ NO 23. Are Correct Detection Levels being used for all LTMP/STMP Monitoring? x YES ❑ NO 24. Is LTMP/STMP Data Maintained in a Table or Equivalent? x YES ❑ NO Is Table Adequate? x YES ❑ NO 25. All LTMP/STMP effluent data reported on Discharge Monitoring Report? x YES ❑ NO 26. If NO to 23 - 26, list violations 27. Should any Pollutants of Concern be Eliminated from or Added to LTMP/STMP? ❑ YES x NO 28. PRETREATMENT PROGRAM ELEMENTS REVIEW— Please review POTW files, verify POTW has copy of Program Element in their files, complete with supporting documents and copy of PERCS Approval Letter, and dates consistent with Program Info: NC DWQ Pretreatment Compliance Inspection (PCI) Form Updated 7/25/07 Page 1 DocuSign Envelope ID: 4F1ADC05-2FCB-4C37-AD58-EBECE3187F8C Program Element Last Submittal Date In file? Last Approval Date In file Date Next Due, If Applicable Headworks Analysis (HWA) 3/31/2022 x Yes ❑ No 11/30/2018 x Yes ❑ No 12/01/2021 Industrial Waste Survey (IWS) 08/08/2018 x Yes ❑ No 11/08/2012 ❑ Yes x No Sewer Use Ordinance SUO 10/11/12 x Yes ❑ No 10/05/15 x Yes ❑ No Enforcement Response Plan (ERP) 08/20/2015 x Yes ❑ No 12/20/95 x Yes ❑ No Long Term Monitoring Plan (LTMP) 10/21/04 x Yes ❑ No 10/29/04 x Yes ❑ No INDUSTRIAL USER PERMIT (IUP) FILE REVIEW (3 IUP FILE REVIEWS OR 1 FILE REVIEW AND 1 IU INSPECTION) 29. User Name 1.Beocare 2. 3. 30. IUP Number 0008 31. Does File Contain Current Permit? x Yes ❑ 1 ❑ Yes ❑ No ❑ Yes ❑ No 32. Permit Expiration Date 12/21/2022 33. Categorical Standard Applied (I.E. 40 CFR, Etc.) Or N/A NA 34. Does File Contain Permit Application Completed Within One Year Prior x Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No to Permit Issue Date? *Greer First Permit* 35. Does File Contain an Inspection Completed Within Last Calendar Year? x Yes ❑ No ❑Yes ❑ No ❑Yes ❑ No 36. a. Does the File Contain a Slug/Spill Control Plan? a. ❑Yes xNo a. []Yes ❑No a. ❑Yes []No b. If No, is One Needed? See Inspection Form from POTW b. ❑Yes xNo b. ❑Yes ❑No b. ❑Yes ❑No 37. For 40 CFR 413 and 433 TTO Certification, Does File Contain a Toxic ❑Yes❑NoxN/A ❑Yes❑No❑N/A ❑Yes❑No❑N/A Organic Management Plan (TOMP)? 38. a. Does File Contain Original Permit Review Letter from the Division? a. xYes [:]No a. ❑Yes ❑No a. ❑Yes []No b. All Issues Resolved? *Retro date was fixed.* b.❑Yes❑No❑N/A b.❑Yes❑No❑N/A b.❑Yes❑No❑N/A 39. During the Most Recent Semi -Annual Period, Did the POTW Complete x Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No its Sampling as Required by IUP, including flow? Flow -Water Meter 40. Does File Contain POTW Sampling Chain -Of -Custody Forms? x Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No 41. During the Most Recent Semi -Annual Period, Did the SIU Complete its ❑Yes❑NoxN/A ❑Yes❑No❑N/A ❑Yes❑No❑N/A Sampling as Required by IUP, including flow? 41b. During the Most Recent Semi -Annual Period, Did SIU submit all reports ❑Yes❑NoxN/A ❑Yes❑No❑N/A ❑Yes❑No❑N/A on time? 42a. For categorical IUs with Combined Wastestream Formula (CWF), does ❑Yes❑NoxN/A ❑Yes❑No❑N/A ❑Yes❑No❑N/A file includeprocess/dilution flows as Required by IUP? 42b. For categorical IUs with Production based limits, does file include xYes❑No❑N/A ❑Yes❑No❑N/A ❑Yes❑No❑N/A production rates and/or flows as Required by IUP? 43a. During the Most Recent Semi -Annual Period, Did the POTW Identify ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No All Limits Non -Compliance from Both POTW and SIU Sampling? No Violations 43b. During the Most Recent Semi -Annual Period, Did the POTW Identify ❑Yes❑NoxN/A ❑Yes❑No❑N/A ❑Yes❑No❑N/A All Re porting_Non-Compliance from SIU Sampling? 44. a. Was the POTW Notified by SIU (Within 24 Hours) of All Self- a.❑Yes❑NoxN/A a.❑Yes❑No❑N/A a.❑Yes❑No❑N/A Monitoring Violations? b. Did Industry Resample and submit results to POTW Within 30 Days? b.❑Yes❑NoxN/A b.❑Yes❑No❑N/A b.❑Yes❑No❑N/A c. If applicable, Did POTW resample within 30 days of becoming aware ❑ c.Yes❑NoxN/A of SIU limit violations in the POTW's sampling of the SIU? c.❑Yes❑No❑N/A c.❑Yes❑No❑N/A 46. During the Most Recent Semi -Annual Period, Was the SIU in SNC? ❑ Yes x No ❑ Yes ❑ No I ❑ Yes ❑ No 47. During the Most Recent Semi -Annual Period, Was Enforcement Taken xYes❑No❑N/A ❑Yes❑No❑N/A ❑Yes❑No❑N/A as Specified in the POTW's ERP (NOVs, Penalties, timing, etc.)? Due to delayed Consent Order. 48. Does the File Contain Penalty Assessment Notices? ❑Yes❑NoxN/A ❑Yes❑No❑N/A ❑Yes❑No❑N/A 49. Does The File Contain Proof Of Penalty Collection? ❑Yes❑NoxN/A ❑Yes❑No❑N/A ❑Yes❑No❑N/A 50. a. Does the File Contain Any Current Enforcement Orders? a.xYes❑No❑N/A a.❑Yes❑No❑N/A a.❑Yes❑No❑N/A b. Is SIU in Compliance with Order? b.xYes❑No❑N/A b.❑Yes❑No❑N/A b.❑Yes❑No❑N/A 51. Did the POTW Representative Have Difficulty in Obtaining Any of This ❑ Yes x No ❑ Yes ❑ No El Yes ❑ No Requested Information For You? F11 FILE REVIEW COMMENTS: NC DWQ Pretreatment Compliance Inspection (PCI) Form Updated 7/25/07 Page 2 DocuSign Envelope ID: 4F1ADC05-2FCB-4C37-AD58-EBECE3187F8C INDUSTRY INSPECTION PCS CODING: Trans.Code Main Program Permit Number I -NJ INIC10 101213171316 MM/DD/YY Inspec.Type Inspector Fac. Type 01 110 1 09 1 L1—j L S j L 2 (DTIA) (TYPI) (IINSP) (FACC) 1. Industry Visited: Beocare 2. Industry Address:_1905 International Drive, Hudson, NC 3. Type of Industry/Product:_Medical undergarments with dye process. 4. Industry Contact:_JR McCormick Title:Operations Manager Phone: 828-449-6082 Fax: 5. Does the POTW Use the Division Model Inspection Form or Equivalent? ® YES ❑ NO 6. Did the POTW Contact Conduct the Following Parts of the Industrial Inspection Thoroughly? Comments: A. Initial Interview ® YES ❑ NO B. Plant Tour ® YES ❑ NO C. Pretreatment Tour ® YES ❑ NO D. Sampling Review ® YES ❑ NO E. Exit Interview ® YES ❑ NO Industrial Inspection Comments: A complete inspection was conducted as part of the PCI. The IU reports they have resolved the Cr issue and sampling results reflect this. The IU needs to respond to the NOV in a formal, written manner. OVERALL SUMMARY AND COMMENTS: Comments: 1) Ms. Triplett is currently serving as the WWTP Superintendent, Lab Manager and Pretreatment Coordinator. This is a large and diverse workload for a single individual. 2) Excela has been identified as an IUP in the most recent IWS. The Long Form has been completed and submitted to PERCS, and they have been identified as a CIU. Requirements: _IU must complete written response to NOV. Recommendations: 1) Appoint a Pretreatment Coordinator as a new and distinct position from the other roles currently being performed by the WWTP Superintendent. 2) Coordinate with PERCS to develop and IUP for Excela and being regulating/inspecting/sampling them accordingly. NOD: ❑ YES x NO NOV: ❑ YES x NO QNCR: ❑ YES x NO POTW Rating: Satisfactory X Marginal UnSatisfactory DocuSigned by: fi� (�uw. PCI COMPLETED BY: DATE: 01/11/2019 082B1105A3CA418... NC DWQ Pretreatment Compliance Inspection (PCI) Form Updated 7/25/07 Page 3 DocuSign Envelope ID: 4F1ADC05-2FCB-4C37-AD58-EBECE3187F8C United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN I 2 IF I 3 I NCO023736 111 12 I 19/01/09 I17 18 L o j 19 L G] 201 I 2111111111111111111III1111I111111_11111111111 f6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 671 70 I I 71 I I 72 I r I u I� 73 I I 174 751 I I I I I I I80 I I i Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES oermit Number) 09:30AM 19/01/09 14/07/01 Gunpowder Creek WWTP 450 Pine Mtn Rd Exit Time/Date Permit Expiration Date Hudson NC 28638 01:00PM 19/01/09 19/03/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Elisa Robbins Triplett/ORC/828-757-2198/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Monte L Wall,PO Box 958 Lenoir NC 286450958//828-757-2198/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Pretreatment Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Timothy H Heim ARO WQ//828-296-4665/ D S'g dby: C. (M6 f�Uwt 1/15/2019 Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date D... Sig—d bY: 1/15/2019 EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# DocuSign Envelope ID: 4F1ADC05-2FCB-4C37-AD58-EBECE3187F8C NPDES yr/mo/day Inspection Type (Cont.) NCO023736 I11 121 19/01/09 117 18 1 p I Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Tim Heim of the Asheville Regional Office performed a Pretreatment Compliance Inspection on January 10th, 2019. Lisa Triplett (Lenoir WWTP Manager, Lab Supervisor & Pretreatment Coordinator) and Matthew Mackie assisted with the inspection and with records and sampling results review. An inspection of Industrial User Beocare (IUP # 0008) was performed as part of the inspection. JR McCormick, The Operations Manager, was present during the IU inspection component. The pretreatment program, associated record keeping, and the relationship with the IU were in good order at the time of the inspection and compliant with permit conditions. The IU needs to respond in written form to the NOV related to chromium exceedances that has since been reported to be resolved. A new Industrial User: Excela, has been identified during a recent IWS and sampling data of the wastestream has been analyzed. The associated long form has been completed and submitted to PERCs, the town is coordinating with PERCS to develop an IUP for this CIU. See attached NC DEQ Pretreatment Compliance Audit form for details. Page# DocuSign Envelope ID: 4F1ADC05-2FCB-4C37-AD58-EBECE3187F8C Permit: NC0023736 Inspection Date: 01/09/2019 Owner - Facility: Gunpowder Creek WWTP Inspection Type: Pretreatment Compliance Yes No NA NE Page#