Loading...
HomeMy WebLinkAboutNC0089052_Renewal Application_20190108 4'tseAtAt ,i,,,,...— .,,,,,*0 er, ....1.\ li. ROY COOPER NORTH CAROLINA Gore nor Environmental Quality MICHAEL S_REGAN Secretary LINDA CULPEPPER Interim Director January 08, 2019 Alec Chaplin,Jr Zooland Family Campground LLC PO Box 12187 Columbia, SC 29211 Subject: Permit Renewal Application No. NC0089052 Zooland Family Campground Randolph County Dear Applicant: The Water Quality Permitting Section acknowledges the December 31, 2018 receipt of your permit renewal application and supporting documentation. Your application will be assigned to a permit writer within the Section's NPDES WW permitting branch. Per G.S. 150B-3 your current permit does not expire until permit decision on the application is made. Continuation of the current permit is contingent on timely and sufficient application for renewal of the current permit.The permit writer will contact you if additional information is required to complete your permit renewal. Please respond in a timely manner to requests for additional information necessary to allow a complete review of the application and renewal of the permit. Information regarding the status of your renewal application can be found online using the Department of Environmental Quality's Environmental Application Tracker at: https://deq.nc.gov/permits-regulations/permit-guidance/environmental-application-tracker If you have any additional questions about the permit, please contact the primary reviewer of the application using the links available within the Application Tracker. Sincerely, ..3CINJA4-41A Wren Thedford - Administrative Assistant Water Quality Permitting Section ec: WQPS Laserfiche File w/application D_EQ -?), ,„ ,„„ ......,.\.„.,, North Carolina Department of Environmental Quality I Division of Water Resources 1617 Mail Service Center I Raleigh,North Carolina 27699-1617 919-807-6300 DIEHL & PHILLIPS, P.A. CONSULTING ENGINEERS WILLIAM C.DIEHL,P.E. 1500 Piney Plains Road,Suite 200 JOHN F.PHILLIPS,P.E. Cary,North Carolina 27518 ALAN IL KEITH,P.E. Telephone(919)467-9972—Fax(919)467-5327 RECEIVED/UENR/DWRR TRANSMITTAL JAN 0 3 2019 December 31, 2018 Water Resources TO: NC DEQ / DWR/ NPDES Permitting Section 91 FROM: John F. Phillips, P.E.,on behalf of permittee Alec H. Chaplin, Jr. RE: Renewal Application for NPDES Permit NC0089052 Zooland Family Campground No. Of Description Remarks Copies Please note the description of the existing wastewater treatment system in the current issue of this permit is incorrect. The 2 Form D 6/2017 description provided in item 9 of the enclosed application is correct, and reflects the system that was approved under the Authorization to Construct. Please contact me if you have any questions regarding the enclosed application. Cc: Mr. Alec H. Chaplin, Jr. Mr. Alan Gaddis, ORC NPDES APPLICATION - FORM D For privately-owned treatment systems treating 100%domestic wastewaters<1.0 MGD Mail the complete application to: NC DEQ/DWR/NPDES 1617 Mail Service Center, Raleigh, NC 27699-1617 NPDES Permit NC0089052 If you are completing this form in computer use the TAB key or the up—down arrows to move from one field to the next. To check the boxes, click your mouse on top of the box. Otherwise,please print or type. 1. Contact Information: Owner Name Alec H.Chaplin,Jr. Facility Name Zooland Family Campground Mailing Address P.O. Box 12187 City Columbia State/Zip Code S.C.29211 Telephone Number (803)799-9683 Fax Number ( ) e-mail Address alecjr@chaplin-co.com 2. Location of facility producing discharge: Check here if same address as above 0 Street Address or State Road 3671 Pisgah Covered Bridge Road City Asheboro State/Zip Code N.C. 27205 County Randolph 3. Operator Information: Name of the firm,public organization or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name AG Environmental Management, LLC Mailing Address 6119 Asheton Drive City Trinity State/Zip Code N.C. 27370 Telephone Number (336)5619178 Fax Number ( ) e-mail Address Arg619@northstate.net 1 of 3 Form-D 6I2017 NPDES APPLICATION -FORM D For privately-owned treatment systems treating 100%domestic wastewaters<1.0 MGD 4. Description of wastewater: Facility Generating Wastewater(check all that apply): Industrial ❑ Number of Employees Commercial ❑ Number of Employees Residential ❑ Number of Homes School ❑ Number of Students/Staff Other Explain: See below Describe the source(s)of wastewater(example:subdivision, mobile home park,shopping centers, restaurants, etc.): Source of wastewater is an RV park/campground. Design flow of the constructed treatment plant is 6,000 gpd, based on 68 gpd per campsite and a maximum of 88 campsites(design flows were based on water records). Number of persons served: NA—see flow explanation above 5. Type of collection system ® Separate(sanitary sewer only) ❑Combined (storm sewer and sanitary sewer) 6. Outfall Information: Number of separate discharge points 1 Outfall identification number(s) 001 Is the outfall equipped with a diffuser? ❑ Yes ►14 No 7. Name of receiving stream(s) (NEW applicants:Provide a map showing the exact location of each outfal): Little River 8. Frequency of Discharge: ® Continuous ❑ Intermittent If intermittent: Days per week discharge occurs: Duration: 9. Describe the treatment system List all installed components, including capacities,provide design removal for BOD, TSS,nitrogen and phosphorus. If the space provided Is not sufficient, attach the description of the treatment system in a separate sheet of paper. One 8,000 gallon septic tank,one 2,000 gallon flow equalization tank with duplex submersible pumps, one 9,600 gallon Moving Bed Biofilm Reactor with duplex blowers and diffused aeration system,one 3,500 gallon clarifier,one 1,500 gallon filter feed tank with duplex submersible filter feed pumps, one 24- inch diameter pressure sand filter,two ultra-violet disinfection systems,one 1,500 gallon clearwell with duplex submersible filter backwash pumps and diffused post-aeration,alkalinity feed system with duplex feed pumps,and one 36 KW standby power generator and automatic transfer switch. Design removals for BOD5—99%removal;TSS—97% removal;Ammonia-N—98%;,TP reduction not required by NPDES permit 10. Flow Information: Treatment Plant Design flow 0.006 MGD 2 of 3 Form-D 612017 NPDES APPLICATION -FORM D For privately-owned treatment systems treating 100%domestic wastewaters<1.0 MGD Annual Average daily flow 0.002598 MGD (for the previous 3 years) Maximum daily flow 0.0153 MGD(for the previous 3 years) 11. Is this facility located on Indian country? ❑ Yes g3 No 12. Effluent Data NEW APPLICANTS:Provide data for the parameters listed. Fecal Coliform, Temperature and pH shall be grab samples,for all other parameters 24-hour composite sampling shall be used. If more than one analysis is reported,report daily maximum and monthly average. If only one analysis is reported,report as daily maximum. RENEWAL APPLICANTS: Provide the highest single reading(Daily Maximum)and Monthly Average over the past 36 months for parameters currently in your permit. Mark other parameters"N/A" Parameter Daily Monthly Units of Maximum Average Measurement Biochemical Oxygen Demand (BODS) 116 6.17 Mg/L Fecal Coliform 2420 108 #/100m1 Total Suspended Solids 30.30 2.77 Mg/L Temperature(Summer) 28.0 24.95 degC Temperature(Winter) 22 17.13 degC pH 8.63 8.28 Su 13. List all permits,construction approvals and/or applications: Type Permit Number Type Permit Number Hazardous Waste(RCRA) NESHAPS(CAA) UIC(SDWA) Ocean Dumping(MPRSA) NPDES 0089052 Dredge or fill(Section 404 or CWA) PSD(CAA) Other Non-attainment program(CM) 14. APPLICANT CERTIFICATION I certify that I am familiar with the information contained In the application and that to the best of my knowledge and belief such information Is true,complete,and accurate. Alec H.Chaplin.Jr. Owner Printed name of Person Signing Title 4- 44° 2_ /2 ( C2//j3 Signature of Applicant �� Date North Carolina General Statute 143-215.6 )(2)states: Any person who knowingly makes any false statement representation,or certification in any application,record,report,plan,or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article,or who falsifies,tampers with,or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article,shall be guilty of a misdemeanor punishable by a fine not to exceed$25,000,or by imprisonment not to exceed six months,or by both. (18 U.S.C.Section 1001 provides a punishment by a fine of not more than$25,000 or imprisonment not more than 5 years,or both,for a similar offense.) 3 of 3 Form-D 612017