Loading...
HomeMy WebLinkAboutDEQ-CFW_00088251z W DEQ-CFW 00088251 f F Form D: Process Information (Page I of 2) Facility ID# 0900009 North Carolina Department of Environment and Natural Resources Division of Air Quality Calendar 2000 Air Pollutant Point Source Emissions Inventory 1. Source ID No. (same as in permit) NS-J3 (NS-J in Title V) 2. Process Description: Nafion® Semiworks 3 Facility 4. Maximum Process Rate: 4. CY 2000 Process Throughput: (Ex: gal/hr, mmcf/hr) Confidential (Ex: lb., gal) Confidential include units 5. Normal Operating Schedule: Hours per Days per Day Week 6. Typical Start & End Times For Process: 7. Percentage Annual Throughput: Dec -Feb 25 Mar -May Start: include units Weeks Hours per per Year Year Confidential Continuous End: 25 June -Aug 25 Sept -Nov 25 8. Capture Efficiency (% of Emissions from this Process Vented Through Control Device): N/A 9. Control Device Descriptions Primary 0 Secondary: None 10. Combined (Net) Control Device Efficiency (%): (Control efficiency is pollutant specific) PM PM-10 PM-2.5 SO2 NOx VOC N/A 11. ANNUAL FUEL USAGE For This Process (Coal, oil, wood, natural as, etc.) -Use additional sheets as needed. if Type of Fuel Used in This Process/Source Amount (gal, tons, mmcf/year) % Sulfur % Ash ou do not rovide annual throu h ut our invento will be deemed incom lete and returned to you Y P g P Y rY P To review instructions or get a new copy, go to web page: htti):Hdao.state.nc.us/Offices/Planning/Attainment/est.html or http://d aa.state.nc.us/OfficesfPlanning/Attainment/ 1999/99form s.html Information on Form D cannot be held confidential. DEQ-CFW 00088252 Form 4: Process Information (Page 2 of 2) CY 2000 Facility ID# 0900009 Source ID# NS-J3 Actual Emissions per Pollutant Listed for Source/Process Identified Above: Aglbkkttach calculations and documentation of emission factors or other estimation methods used. E • "Per Ton" Pollutant: PM PM-10 PM-2.5 SO-1 Nox VOC CO Actual Emissions: Tons/year 0.0014 ***All Other HAPs/TAPS Per Instructions (use additional sheets if necessary)*** Pollutant CAS # Emitted lbs./ r. Comments Chlorine 7782-50-5 Fluorine 7782-41-4 Hydrazine 302-01-2 Hydrogen Chloride (As weight of HCl in solutions) 7647-01-0 Hydrogen Fluoride (As weight of HF in solutions) 7664-39-3 Hydrogen Sulfide 7783-06-4 Lead (As metal or compounds -mass of total) LEADCPDS Methyl Chloroform (Not a VOC, by rule) 71-55-6 Methylene Chloride (Not a VOC, by rule) 75-09-2 Ozone (Not expected as a facility emission) 10028-15-6 Perchloroethylene (Not a VOC, by rule) 127-18-4 Phosphine 7803-51-2 List all other HAP/TAPS below IN ALPHABETICAL ORDER, Per Instructions. Use more sheets, as needed Nitric Acid 7697-37-2 0 Information on Form D cannot be held confidential. DEQ-CFW 00088253 • �J 2000 Air Emissions Determination Nafion° Semiworks 3 Facility (NS-J3) Source of VOC's is exclusively dimethyl sulfoxide (DMSO) In 2000, approximately one (1) gallon of hydrolysis solution was used. This solution contains no more than 30% DMSO. Assume all DMSO was lost as a VOC. 1 gallon of solution x 30% DMSO = 0.3 gallons of DMSO 0.3 gal DMSO x 9.13 lb/gal = 2.74 lb DMSO = 0.0014 Ton DMSO (VOC) This is a extremely high estimate of the air emissions, since the vapor pressure of DMSO is 0.5 mmHg at 20°C, and therefore its evaporation rate would be minuscule. Additionally, all the hydrolysis solution is collected in a drum and pumped into the waste hydrolysis tank in the Products Area. Field tests have indicated that there is no loss of nitric acid (HNO3) to the air during normal operation. DEQ-CFW 00088254