Loading...
HomeMy WebLinkAboutDEQ-CFW_00088149DEQ-CFW 00088149 Form D: Process Information (Page 1 of 2) Facility ID# 0900009 • North Carolina Department of Environment and Natural Resources Division of Air Quality Calendar 2000 Air Pollutant Point Source Emissions Inventory 1. Source ID No. (same as in permit) BS-1 (BS-A in Title V) 2. Process Description: Butyraldehyde Storage Tank 4, Maximum Process Rate: 4. CY 2000 Process Throughput: (Ex: gal/hr, mmcf/hr) Confidential (Ex: lb, gal) Confidential include units 5. Normal Operating Schedule: Hours per Days per Day Week 6. Typical Start & End Times For Process: Start Weeks per Year Continuous include units Hours per Year Confidential End: 7. Percentage Annual Throughput: Dec -Feb 25 Mar -May 25 June -Aug 25 Sept -Nov 25 100% 8. Capture Efficiency (% of Emissions from this Process Vented Through Control Device): 9. Control Device Descriptions Primary Brine Cooled Condenser BCD-1 (Title V BCD -A) • Secondary: Closed -loop Loading Procedure 10. Combined (Net) Control Device Efficiency (%): PM (Control efficiency is pollutant specific) PM-10 PM-2.5 SO2 NOx VOC 93% 11. ANNUAL FUEL USAGE For This Process Coal, oil, wood, natural as, etc. -Use additional sheets as needed. Type of Fuel Used in This Process/Source Amount (gal, tons, mmcf/year) % Sulfur % Ash f you do not provide annual throuchout vour inventory will be deemed incomplete and returned to you review instructions or get a new copy, go to web page: httn://daa.state.nc.us/Offices/Planning/Attainment/est.html or Information on Form D cannot be held confidential. DEQ-CFW 00088150 Form D: Process Information (Page 2 of 2) CY 2000 Facility ID# 0900009 Source ID# BS-1 Is E Actual Emissions Per Pollutant Listed for Source/Process Identified Above: Attach calculations and documentation of emission factors or other estimation methods used. "Per Ton" Pollutant: PM PM-10 PM-2.5 S02 NOX VOC CO Actual Emissions: Tons/year 1.17 ***All Other HAPs/TAPs Per Instructions (use additional sheets if necessary)*** Pollutant CAS # Emitted lbs./ r. Comments Chlorine 7782-50-5 Fluorine 7782-41-4 Hydrazine 302-01-2 Hydrogen Chloride (As weight of HCl in solutions) 7647-01-0 Hydrogen Fluoride (As weight of HF in solutions) 7664-39-3 Hydrogen Sulfide 7783-06-4 Lead (As metal or compounds -mass of total) LEADCPDS Methyl Chloroform (Not a VOC, by rule) 71-55-6 Methylene Chloride (Not a VOC, by rule) 75-09-2 Ozone (Not expected as a facility emission) 10028-15-6 Perchloroethylene (Not a VOC, by rule) 127-18-4 Phosphine 7803-51-2 List all other HAP/TAPs below IN ALPHABETICAL ORDER, Per Instructions. Use more sheets, as needed Information on Form D cannot be held confidential. DEQ-CFW 00088151 • • 11 2000 AIR EMISSIONS INVENTORY BUTYRALDEHYDE STORAGE TANK (BS-1) EMISSIONS SUMMARY PROCESS EMISSIONS: VOC EMISSIONS VOC EMISSIONS (lb/year) P BA Condenser 751 0.38 VOC VOC VOC EMISSIONS EMISSIONS EMISSIONS worst case with 67% with 67% FUGITIVE EMISSIONS: scenario based reduction for reduction for on AP-42 "Good" control "Good" control (lb/year) (lb/year) (TPY) Unloading System 2,750 908 0.45 Recirculation System 126 42 0.02 BA Storage Tank 1917 633 0.32 TOTAL EMISSIONS: 2,334 1.17 DEQ-CFW 00088152 • 2000 AIR EMISSIONS INVENTORY BUTYRALDEHYDE STORAGE TANK (BS-1) EMISSIONS DETERMINATION Butyraldehyde (BA) emissions from Storage Tank Condenser (BCD-1): BA (breathing losses) to condenser = 2,482 lb/yr BA Vapor Pressure at 71.37 °F = 1.844 psi BA Vapor Pressure at 32 °F = 0.558 psi 0 lb (O.558psi) lb BA emissions from condenser = 2,482 n X 1.844 psi = 751- (See information from Title V - Form D6 on following pages) Butyraldehyde (BA) fugitive emissions from BA Storage Tank: (See information on following pages) DEQ-CFW 00088153 BA Fugitive Emissions Page 1 of 2 20 00 BUTYRALDEHYDE FUGITIVE EMISSIONS CALCULATIONS i. FIXED LOSSES A. Unloading System Leak rate = (pump losses + liquid valve losses + gas valve losses + flange losses) x (weight fraction BA) x (total hours) = [(1)(0.109) + (9)(0.016) + (1)(0.012)+ (27)(0.0018)] (1.0) (8760 hrs.) = [0.109 + 0.144 + 0.012 + 0.0491] (1.0) (8760) = (0.314 lbs./hr) (8760 hrs/yr.) = 2,750lbs./yr. B. Vapor Return System Area average Temp. = 75°F BA Vapor Pressure = 110 mmHg (from Hercules vapor press. curve) BA mole fraction in vapor vapor pressure of BA total pressure vapor pressure of BA gauge press. + atms. pressure G 10 mmHg) 0 atm/760 mmHg) (4 inch H2O + 406.8 inch H20) (1 atm/406.8 inch H20) = 0.143 mole BA / mole of gas Leak rate = [gas valve losses + flange losses] (wt. fraction BA) (tot. operating hrs.) [ (2)(0.015) + (5)(0.0018) ] (0.143 mol BA) 721b BA) mol as) (8760 hr) ( mol BA ) (28 lb gas) ( yr. ) = (0.030 + 0.0090) (0.143) (2.57) (8760) 0 = 125.61b/yr. DEQ-CFW 00088154 BA Fugitive Emissions Page 2 of 2 C. BA Storage Tank 1. Liquid Flanges/Valves Leak rate = (liq. valve losses + flange losses) (weight fraction BA) (tot. oper. hrs.) = [(2)(0.016) + (8)(0.0018)] (1.0) (8760)] = [0.032 + 0.014] (1) (8760) = 406lbs./yr. 2. Vapor Flanges/Conservation Vents Leak Rate = (C/V losses + vapor flange losses) (weight fraction BA) (Tot. oper. hrs.) = [(2)(0.224) + (12)(0.0018)] (0.143) (2.57) (8760) = [0.448 + 0.0216] (0.143) (2.57) (8760) = 1,511lb/yr. 3. Total Leak Rate = 406 + 1,511 = 1,9171b/yr. E 1] DEQ-CFW 00088155