Loading...
HomeMy WebLinkAboutNCG550371_Compliance Evaluation Inspection_20181204 e. Fl ip * , -4:-1 ROY COOPER NORTH CAROLINA Governor Environmental Quality MICHAEL S.REGAN Secretary LINDA CULPEPPER _ Interim Director December 4, 2018 Larry R. Sigmon - 713 Cascade Rd • Eden, NC 27288 SUBJECT: Compliance Evaluation Inspection Report and Notice of Deficiency Certificates of Coverage NCG550371 and NCG550372 NPDES General Permit NCG550000 _ NOD Tracking Number NOD-2018-PC-0331 Facility Located at 713 Cascade Ave, Rockingham County Dear Mr. Sigmon: On October 15, 2018, Paul DiMatteo of this office conducted Compliance Evaluation Inspection on the subject wastewater treatment facilities, one for the main house (NCG550372) and one for a rental house on the same property (NCG550371). i The systems each consist of a septic tank, subsurface sand filter, chlorinator, effluent pump and shared outfall with final disposal to an unnamed tributary to Dry Creek, class C waters in the Roanoke River Basin. No sewage malfunction was observed at or around the septic tanks. The outfall was not located during the inspection. At the main system, chlorine was not present in the chlorinators and a bypass pump was set up in the effluent pump tank and terminated in the nearby field.'Please note that the Permit requires that"the Permittee shall at all times properly operate and maintain all facilities and systems of treatment and control (and related appurtenances) which are installed or used by the Permittee to achieve compliance with the conditions of this permit." (Part II, Section C.2). Therefore, the effluent pump must be repaired, and an adequate supply of wastewater strength chlorine tablets must be maintained in the chlorinators. During a follow up conversation on December 3, you said that you would have an electrician repair the control panel once the weather allowed. Please contact the inspector once the repair has been made. Please also note that the General Permit requires annual effluent monitoring as specified in Part I.C. The General Permit was renewed effective October 23, 2018.A copy of the most recent Technical Bulletin is enclosed. A copy of the General Permit is available by searching on our website ( https://deq.nc.gov/about/divisions/water-resources ) or can be obtained by contacting the inspector. You will be contacted by the Division through separate correspondence regarding the status of renewal for your Certificate of Coverage. Please review these documents carefully. £D_E NORTH.CAROLINA DoNm�mEsffitaamttltlati North Carolina Department of Environmental Quality I Division of Water Resources Winston-Salem Regional Office j 450 Hanes WU Road,Suite 300 I Winston-Salem,North Carolina 27103 336.776.9800 i s If you'should have any questions, please do not hesitate to contact Paul DiMatteo at 336-776-9691 or our office at 336-776-9800. Sincerely, . V K-� Sherri V. Knight, P.E. Regional Supervisor Water Quality Regional Operations Division of Water Resources Attachments: EPA Water Compliance Inspection Report NCG5500000 Technical Bulletin cc: WSRO NPDES Unit Page 2 of 2 , United States Environmental Protection Agency Form Approved. EPA Washington,D.C.20460 OMB No 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A National Data System Coding(i.e.,PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 Lj I 2 I5 I 3 I NCG550372 111 121 18/10/15 I17 18 I r I 19 I I 20I I 21IIII I II I I III I I I I I I I I I I I I I I I I I I I I I I III l I l I I r6 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA — Reserved 67I I 70I I 71 I I 72 LJI N I I I I74 75I I I I I I I I80 Section B Facility Data Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 12 05PM 18/10/15 13/08/01 713 Cascade Avenue residence 713 Cascade Ave Exit Time/Date Permit Expiration Date 12 25PM 18/10/15 18/07/31 Eden NC 27288 Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /// 1 Name,Address of Responsible Official/Title/Phone and Fax Number Contacted Larry R Sigmon,713 Cascade Rd Eden NC 27288//336-635-2186/ No Section C.Areas Evaluated During Inspection(Check only those areas evaluated) II Permit II Operations&Maintenance El Facility Site Review Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date Paul DiMatteo WSRO WQ//336-776-9691/ C-P4%—..2 illAASVC:=) 1 lAlk Signature of Management Q A Reviewer/ r(p� Agency/Office/Phone and Fax Numbers 0191 Date 1 I EPA Form 3560-3(Rev 9-94)Previous editions are obsolete Page#' 1 r 1 $ NPDES yr/mo/day Inspection Type (Cont) 1 3I NCG550372 I11 121 18/10/15 11 7 1 8 —i Section D Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) I spoke to Mr. Sigmon on 10/12/2018 before the inspection. During the pre-inspection interview, he said: -No recent issues -He may need to replace a pump soon -Chlorine is added periodically -Septic tank was pumped 2 years ago -He knows where the discharge is - He does see water at the discharge periodically - He does not conduct annual sampling Site visit conducted on 10/15/2018. There are 2 systems on this property-one for the main house, and _ one for the guest house. For this system (main),there was no chlorine in the chlorinators, and there was some sort of hose coming out of the effluent pump tank that led to the nearby field. I searched around the staff report's GPS coordinates for the outlet pipe and could not find it. I spoke to Mr. Sigmon after the inspection, and he said the hose was temporary to pump the wet well down since the pump had gone out. Permitted discharge point is apparently somewhere in the field. I asked him to have the pump replaced so that the effluent goes to the specified discharge location and call back, and to check the chlorinators. • Page# 2 s Permit: NCG550372 Owner-Facility: 713 Cascade Avenue residence Inspection Date: 10/15/2018 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping'? • ❑ ❑ ❑ Does the facility analyze process control parameters,for ex: MLSS, MCRT, Settleable ❑ ❑ II ❑ Solids, pH, DO, Sludge Judge, and other that are applicable'? Comment Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ I ❑ application'? Is the facility as described in the permit'? • ❑ ❑ ❑ #Are there any special conditions for the permit'? ❑ • ❑ ❑ Is access to the plant site restricted to the general public'? • ❑ ❑ ❑ • Is'the inspector granted access to all areas for inspection'? III ❑ ❑ ❑ Comment: • Pump Station -Effluent Yes No NA NE Is the pump wet well free of bypass lines or structures'? ❑ • ❑ ❑ Are all pumps present'? • ❑ ❑ ❑ Are all pumps operable'? ❑ • ❑ ❑ Are float controls operable' ❑ ❑ ❑ • Is SCADA telemetry available and operational'? ❑ ❑ U ❑ Is audible and visual alarm available and operational'? ❑ ❑ ❑ Comment: See summary. - Disinfection-Tablet Yes No NA NE Are tablet chlorinators operational'? ❑ ❑ ❑ II Are the tablets the proper size and type? ❑ ❑ ❑ • - Number of tubes in use's 2 Is the level of chlorine residual acceptable'? ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup'? ❑ ❑ ❑ • Is there chlorine residual prior to de-chlorination'? ❑ ❑ ❑ • Comment: See summary. Page# 3 , United States Environmental Protection Agency Form Approved. E PA Washington,D C 20460 OMB No 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A National Data System Coding(i.e.,PCS) ' Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN I 21.51 3 I NCG550371 111 121 18/10/15 117 18 ► 19 l G l 201 I 21I I I I I I I I I I I [ I I I I I I I I I I I I I I I I I I I I I I I I I I I I' I ► 166 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA — Reserved ` 67I I 70I I 71 I I 72 LI 731 I 174 75I1 I I I I I I 180 Section B.Facility Data I___J Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 12 05PM 18/10/15 13/08/01 713 Cascade Avenue rental house . Exit Time/Date Permit Expiration Date 713 Cascade Ave 12 25PM 18/10/15 18/07/31 Eden NC 27288 Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /// Name,Address of Responsible Official/Title/Phone and Fax Number Contacted Larry R Sigmon,713 Cascade Rd Eden NC 27288//336-635-2186/ No Section C-Areas Evaluated Dunng Inspection(Check only those areas evaluated) In Permit Facility Site Review Section D.Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date Paul DiMatteo WSRO WQ//336-776-9691/ ?0....-.a DA dit;:, /7/114? Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date •%. / la /Vie EPA Form 3560-3(Rev 9-94)Previous editions are obsolete / Page# 1 NPDES yr/mo/day Inspection Type - 1 31 NCG550371 111 121 18/10/15 I 17 18 C Section D Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) See also the summary for NCG550372 (main house, separate system on same property). I made a site visit on 10/15/2018. For this system, I could not get the lid off the chlorinators, and could not locate the outlet pipe. • • • Page# 2 Permit: NCG550371 Owner-Facility: 713 Cascade Avenue rental house Inspection Date: 10/15/2018 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ E ❑ application? Is the facility as described in the permit? • ❑ ❑ ❑ #Are there any special conditions for the permit? ❑ • ❑ ❑ Is access to the plant site restricted to the general public? • ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? • ❑ ❑ ❑ Comment • Page# 3