HomeMy WebLinkAbout20181716 Ver 1_B-175 SMP_20181218/wo pLl�
I�Il�;hw�ly North Carolina Department of Transportation /
Stormwater I��z
,,,,.,,.,, Highway Stormwater Program
STORMWATER MANAGEMENT PLAN �°"'����%
(Version 2.08; Released April 2018) FOR NCDOT PROJECTS
WBS Element: 14SP.20441.1 TIP No.: SF-430175 County(ies): Haywood Page 1 of 1
General Project Information
WBS Element: 14SP20441.1 TIP Number: SF-430175 Project Type: Bridge Replacement Date: 10/9/2018
NCDOT Contact: Marc Shown, PE Contractor / Desi ner:
Address: 1590 Mail Service Center Address:
Raleigh, NC 27699-1590
Phone: 919-707-6751 Phone:
Email: mshown ncdot. ov Email:
Cit ITown: Waterville Count ies : Ha ood
River Basin s): French Broad CAMA Count ? No
Wetlands within Project Limits? No
Pro'ect Description
Pro'ect Len th lin. miles or feet : 0.10 mi. Surrounding Land Use: Rural-Moauntainous
Proposed Pro'ect Existin Site
Pro'ect Built-Upon Area ac. 0.3 ac. 0.3 ac.
Typical Cross Section Description: 2 10 ft. lanes with 3 ft. grassed shoulders 2 9 ft. lanes with 2 ft. grassed shoulders
Annual Avg Daily Traffic (veh/hr/day): Qualit Im acts 600 Year: 2025 Existin : 440 Year: 2012
General Project Narrative: Replace Bridge 175 over Big Creek on Sr 1332 (Waterville Rd.) in Haywood County. The existing structure is a two span girder bridge. 2@ 42' OAL=84'. The replacement
(Description of Minimization of Water structure is a two span bridge 1@75' 33" box beam and 1@ 40' 21" cored slab OAL = 115' . There will be no deck drains required on the proposed structure. Existing drainage
Quality Impacts) patterns are being maintained and surface runoff is discharged as far away from stream as practicable.
Surface Water Body (1): Big Creek NCDWR Stream Index No.:
NCDWR Surface Water Classification for Water Body Primary Classification: Class C
Supplemental Classification: Trout Waters (Tr) (HQW)
Other Stream Classification:
Impairments:
Aquatic T&E Species? Comments:
NRTR Stream ID: Buffer Rules in Effect: N/A
Project Includes Bridge Spanning Water Body? Yes Deck Drains Discharge Over Buffer? No Dissipator Pads Provided in Buffer? N/A
Deck Drains Discharge Over Water Body? No (If yes, provide justification in the General Project Narrative) (If yes, describe in the General Project Narrative; if no, justify in the
(If yes, provide justification in the General Project Narrative) General Project Narrative)