15A NCAC 02T .0300 - FAST TRACK SEWER SYSTEM EXTENSION APPLICATION
Division of Water Resources INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION
This application is for sewer extensions involving gravity sewers, pump stations and force mains, or any combination that has been
certified by a professional engineer and the applicant that the project meets the requirements of 15A NCAC 02T and the Division's
Minimum Design Criteria and that plans, specifications and supporting documents have been prepared in accordance with, 15A
NCAC 02T, 15A NCAC 02T .0300, Division policiLs and good eneineerine practices.
While no upfront engineering design documents are required for submittal, in accordance with 15A NCAC 02T .0305(b), design
documents must be prepared prior to submittal of a fast track permit application to the Division. This would include plans, design
calculations, and project specifications referenced in I SA NCAC 02T .0305 and the applicable minimum design criteria. These
documents shall be available upon request by the Division.
Projects that are deemed permitted (do not require a permit from the Division) are explained in 15A NCAC 02T.0303.
ot
le
Projects Projecgsbhatrequire an environmental the
track assessmerocess nt insaccordancsubmitted
with I SAfull
NCAC I C 0lOC Dcpf of Environmental Quality
Projects that do not meet any part of the minimum design criteria (MDC) document;
r Projects that involve a variance from the requirements of 15A NCAC 2T; OCT 2 2 2018
r Pressure sewer systems utilizing septic tank -effluent pumps (STEPs) or simplex grinder pumps;
STEP or simplex grinder pumps connecting to pressurized systems (e.g. force mains);
Vacuum sewer systems. Raleigh Regional office
General - When submitting an application, please use the following instructions as a checklist in order to ensure all required items
are submitted. Adherence to these instructions and checking the provided boxes will help produce a quicker review time and
reduce the amount of requested additional information. Failure to submit all required items will necessitate additional
processing and review time, and may result in return of the application. Unless otherwise noted, the Applicant shall submit
one original and one copy of the application and supporting documentation.
A. One Original and One Copy of Application and Supporting Documents
® Required unless otherwise noted
B. Cover Letter (Required for All Application Packages):
® List all items included in the application package, as well as a brief description of the requested permitting action.
Be specific as to the system type, number of homes served, flow allocation required, etc.
If necessary for clarity, include attachments to the application form.
C. Application Fee (All New and Major Modification Application Packages):
® Submit a check or money order in the amount of S480.00 dated within 90 days of application submittal.
D Payable to North Carolina Department of Environmental Quality (NCDEQ)
D. Fast Track (Form: FTA 04-16) Application (Required for All Application Packages):
® Submit the completed and appropriately executed application.
➢ If necessary for clarity or due to space restrictions, attachments to the application may be made.
® If the Applicant Type in Item 1.2 is a corporation or company, provide documentation it is registered for business with
the North Carolina Secretary of State.
® If the Applicant Type in Item I.2 is a partnership or d/b/a, enclose a copy of the certificate filed with the Register of
Deeds in the county of business.
® The Project Name in Item 11.1 shall be consistent with the project name on the flow acceptance letters, agreements, etc.
® The Professional Engineer's Certification on Page 5 of the application shall be signed, sealed and dated by a North
Carolina licensed Professional Engineer
® The Applicant's Certification on Page 5 of the application shall be signed in accordance with 15A NCAC 02T .0106(b).
Per I5A NCAC 02T .0106(c), an alternate person may be designated as the signing official if a delegation letter is
provided from a person who meets the criteria in 15A NCAC 02T .0106(b).
INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page I of
E. Flow Tracking/Acceptance Form (Form: FTSE 04-16) (If Applicable):
® Submit the completed and executed FTSE form from the owners of the downstream sewers and treatment facility.
Multiple forms maybe required where the downstream sewer owner and wastewater treatment facility are different.
The flow acceptance indicated in form FTSE must not expire prior to permit issuance and must be dated less than one
year prior to the application date.
Submittal of this application and form FTSE indicates that owner has adequate capacity and will not violate G.S. 143-
215,6Jal.
D Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific FTSE.
F. Site Maps (All Application Packages):
® Submit an 8.5-inch x I 1-inch color copy of a USGS Topographic Map of sufficient scale to identify the entire project
area and closest surface waters.
Location of the project (gravity sewer, pump stations & force main)
Downstream connection points and permit number (if known) for the receiving sewer
® Include a street level map (aerial) showing general project area so that Division staff can easily locate it in the field.
G. Existing Permit (All Modification Packages):
❑ Submit the most recently issued existing permit.
❑ Provide a list of any items within the permit the Applicant would like the Division to address during the permit
modification (i.e., permit description, flow allocation, treatment facility, etc.).
H. Power Reliability Plan (Required if portable reliability option utilized for Pump Station):
❑ Per 15A NCAC' 02'T .0305(h)(1), submit documentation of power reliability for pumping stations.
> This alternative is only available for average daily flows less than 15,000 gallons per day
t It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant and is compatible
with the station. The Division will accept a letter signed by the applicant (see ISA NCAC 02T .0106(b)) or proposed
contractor, stating that "the portable power generation unit or portable, independently -powered pumping units, associated
appurtenances and personnel are available for distribution and operation of this pump station."
If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump
stations' storage capacities and the rotation schedule of the portable power source or pump, including travel
timeframes, shall be provided in the case of a multiple station power outage. (Required at time of certification)
I. Certificate of Public Convenience and Necessity (All Application Packages for Privately -Owned Public Utilities):
❑ Per 15A NCAC 02T .01 I5 a 1 provide the Certificate of Public Convenience and Necessity from the North Carolina
Utilities Commission demonstrating the Applicant is authorized to hold the utility franchise for the area to be served by
the sewer extension, or
❑ Provide a letter from the North Carolina Utilities Commission's Water and Sewer Division Public Staff stating an
application for a franchise has been received and that the service area is contiguous to an existing franchised area or that
franchise approval is expected.
J. Operational Agreements (Applications from HOAIPOA and Developers for lots to be sold):
❑ Home/Property Owners' Associations
❑ Per 15A NCAC 02T .01 15(c). submit the properly executed Operational Agreement FORM: HOA .
❑ Per 15A NCAC 02T .0115(c), submit a copy of the Articles of Incorporation, Declarations and By-laws.
❑ Developers of lots to be sold
❑ Per 15A NCAC 02T .0115(b), submit the properly executed Operational Agreement FORM: DEV .
For more information, visil the Division's collection syslems websile
INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 2 of 3
THE COMPLETED APPLICATION PACKAGE INCLDING ALL SUPPORTING INFORMATION AND
MATERIALS, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE:
REGIONAL, OFFICE
ADDRESS
COUNTIES SERVED
Asheville Regional Office
2090 US Highway 70
Avery, Buncombe, Burke, Caldwell, Cherokee,
Water Quality Section
Swannanoa, North Carolina 28778
Clay, Graham, Haywood, Henderson, Jackson,
(828) 2964500
Macon, Madison, McDowell, Mitchell, Polk,
(828) 299-7043 Fax
Rutherford, Swain, Transylvania, Yancey
Favetteville Regional Office
225 Green Street Suite 714
Anson, Bladen, Cumberland, Hamett, Hoke,
Water Quality Section
Fayetteville, North Carolina 28301-5094
Montgomery, Moore, Robeson, Richmond,
(910) 433-3300
Sampson, Scotland
(910) 486-0707 Fax
Mooresville Regional Office
610 E. Center Avenue
Alexander, Cabarrus, Catawba, Cleveland,
Water Quality Section
Mooresville, North Carolina 28115
Gaston, Iredell, Lincoln, Mecklenburg, Rowan,
(704) 663-1699
Stanly, Union
(704) 663-6040 Fax
Raleigh Regional Office
1628 Mail Service Center
Chatham, Durham, Edgecombe, Franklin,
Water Quality Section
Raleigh, North Carolina 27699-1628
Granville, Halifax, Johnston, Lee, Nash,
(919) 791-4200
Northampton, Orange, Person, Vance, Wake,
(919) 788-7159 Fax
Warren, Wilson
Washington Regional Office
943 Washington Square Mall
Beaufort, Bertie, Camden, Chowan, Craven,
Water Quality Section
Washington, North Carolina 27889
Currituck, Dare, Gates, Greene, Hertford, Hyde,
(252) 946-6481
Jones, Lenoir, Martin, Pamlico, Pasquotank,
(252) 975-3716 Fax
Perquimans, Pitt, Tyrrell, Washington, Wayne
Wilmington Regional Office
127 Cardinal Drive Extension
Brunswick, Carteret, Columbus, Duplin, New
Water Quality Section
Wilmington, North Carolina 28405
Hanover, Onslow, Pander
(910) 796-7215
(910) 350-2004 Fax
Winston-Salem Regional Office
450 W. Hanes Mill Road
Alamance, Alleghany, Ashe, Caswell, Davidson,
Water Quality Section
Suite 300
Davie, Forsyth, Guilford, Rockingham, Randolph,
Winston-Salem, North Carolina 27105
Stokes, Surry, Watauga, Wilkes, Yadkin
(336) 776-9800
INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 3 of
State of North Carolina
DWR
Department of Environmental Quality
Division of Water Resources
15A NCAC 02T .0300 - FAST TRACK SEWER SYSTEM EXTENSION APPLICATION
Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION
Application Number: u i 1 r = (to be completed by DWR)
All items must be completed or the m31211cation will be returned
I. APPLICANT INFORMATION:
I. Applicant's name: Town of Fu ua - arina (company, municipality, HOA, utility, etc.)
2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility
❑ Federal ❑ State/County ® Municipal ❑ Other
3. Signature authority's name: Jav T. Mevem, PE per 15A NCAC„02T .0106(b)
Title: Public Utilities Director
4. Applicant's mailing address: 401 Old Honeycutt Road
City: Fu ua-Varina State: NC Zip: 27526-
5. Applicant's contact information:'
c�
Phone number: (2 D 5G-19.1 l Email Address: jmeyers@fuguay-varina.org fuc uay-varina.ors d
O
co
H. PROJECT INFORMATION: � c G
I. Project name: Arnold Park E ¢
2. Application/Project status: ® Proposed (New Permit) El Existing Permit/Project o •�
C
If a modification, provide the existing permit number: WQ00 and issued date: tL -�
If new construction but part of a master plan, provide the existing permit number: WQ00
3. County where project is located: Wake
4. Approximate Coordinates (Decimal Degrees): Latitude: 35.568572° Longitude:-78.$964¢° Z
5. Parcel ID (if applicable): .2�25
(or Parcel ID to closest downstream sewer)
III. CONSULTANT INFORMATION:
1. Professional Engineer: Thomas Spauidine License Number. 019375
Firm: Spaulding & Norris. PA
Mailing address: 972 Trinity_Rd
City: Ralei0i State: NC Zip: 27607-
Phone number: L9J 954-7990 Email Address: tom spauldingnorris.com
IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION:
1. Facility Name: Harnett Courtly WTTP Permit Number: Wt3900786w-- NCGroZ! 636
Owner Name: Harnett County IV. 4ar-ev A o f f, ( 41 to- -r,( Sr, e e VL C,
V. RECEIVING DOWN T� AI,� , R INFORMATION (if different than WWTF): J r
1. Permit Number(s): Downstream (Receiving) Sewer Size: 8 inch
System Wide Collection System Permit Number(s) (if applicable): WQC$ O1 3
Owner Name(s): -reWil of- rl' wryarl4cI—
FORM: FTA 04-16 Page I of 5
V1. GENERAL REQUIREMENTS
1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached?
❑ Yes ❑No ®NIA
2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational -Agreement (FORM: DEV) been attached?
❑ Yes ❑No ®N/A
3. If the Applicant is a Mome/Prooerty. Owners' Association, has an Operational Agreement (FORM: BOA) been attached?
❑ Yes ❑No ®NIA
4. Origin of wastewater: (check all that apply)-
® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash
❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels
❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse
❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash
❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment)
5. Nature of wastewater: 1.Q_% Domestic/Commercial % Commercial
% Industrial (See 15A NCAC 02T .0103(20
�Is there a Pretreatment Program in effect? ❑ Yes ❑ No
6. Has a flow reduction been approved under 15A NCAC 02T .0114(j)? ❑ Yes ® No4 Nif ?ht f VW4hVMes
If yes, vrovide a copy of flow reduction anproval letter
7. Summarize wastewater generated by project:
Establishment Type (see 011.01140
Daily Design Flow p.t,
No. of Units
Flow
Single Family Units
!l$Q al/day
92
24L, t7Z;pD
gaU
GPD
gal/
GPD
gal/
GPD
gal/
GPD
gal/
GPD
HY� lof�_
}T�
Toth! W-,IUU GPD
a See 15A NCAC 02T .0114(b). (d). (e)(1),and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per
dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas;
and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined
in G.S. 42A4].
b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be
determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data.
S. Wastewater generated by project: 27_,60_ GPD (per 15A NCAC 02T .0114
D Do not include future flows or previously permitted allocations
If permitted flow is zero, indicate why:
❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line
❑ Flow has already been allocated in Permit Number: _
❑ Rehabilitation or replacement of existing sewer with no new flow expected
❑ Other (Explain):
FORM: FTA 04 -16 Page 2 of 5
I
VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC_(Grayity Sewers);
1. Summarize gravity sewer to be permitted:
Size (inches) Length (feet) Material
8 2,076 PVC
➢ Section 11 & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria
➢ Section III contains information related to minimum slopes for gravity sewer(s)
➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC
VHI. PUMP STATION DESIGN CRITERIA (If Applicable) — Z .0305 & MDC (Pump Stations/Force Mains):
COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT
1. Pump station number or name:
2. Approximate Coordinates (Decimal Degrees): Latitude: . alongitude: - °
3. Design flow of the pump station: millions gallons per day (firm capacity)
4. Operational point(s) of the pump(s): _._ _gallons per minute at feet total dynamic head (TDH)
5. Summarize the force main to be permitted (for this Pump Station):
Size (inches) Length (feet) Material
6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1):
❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(l)(B);
➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day
➢ Must be permanent to facility
Or if the pump station has an average daily flow less than 15,000 gallons per day:
❑ Portable power source with manual activation, quick -connection receptacle and telemetry - I5A NCAC 02T
.0305(h)(1)(C)
or
❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C):
➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement)
and is compatible with the station.
➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage
capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided
in the case of a multiple station power outage.
FORM: FTA 04-16 Page 3 of 5
IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(i)):
1. Does the project comply with all separations found in 15A NCAC 02T.0305(f) & (g) ® Yes ❑ No
➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems:
Setback Parameter*
Separation Required
Storm sewers and other utilities not listed below vertical
24 inches
Water mains vertical -water over sewer including in benched trenches
18 inches
Water mains horizontal
10 feet
Reclaimed water lines vertical - reclaimed over sewer
18 inches
Reclaimed water lines horizontal - reclaimed over sewer
2 feet
**Any private or public water supply source, including any wells, WS-1 waters of Class I or
Class I1 impounded reservoirs used as a source of drinking water
100 feet
**Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal
high water or tide elevation and wetlands see item IX.2
50 feet
"Any other stream, lake, impoundment, or ground water lowering and surface drainage
ditches
10 feet
Any building foundation
5 feet
AnX basement
10 feet
Top slope of embankment or cuts of 2 feet or more vertical height
10 feet
Drainage systems and interceptor drains
5 feet
My swimming pools
10 feet
Final earth de vertical
36 inches
D 15A NCAC 02T.0305(e) contains alternatives where separations in 02T.0305(f) cannot be achieved.
➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpaee
➢ If noncompliance with 02T.0305(f) or (e). see Section X of this application
2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ❑ No ® NIA
➢ See the Division's draft separation requirements for situations where separation cannot be meet
➢ No variance is required if the alternative design criteria specified is utilized in design and construction
➢ As built documents should reference the location of areas effected
3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02D .0200? ❑ Yes ❑ No ® NIA
➢ This would include Trout Buffered Streams per 15A NCAC 2B.0202
4. Does the project require coverage/authorization under a 404 Nationwide or ® Yes [:]No
individual permits or 401 Water Quality Certifications?
➢ Information can be obtained from the 401 & Buffer Permitting Branch
5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes [:]No
Per 15A NCAC 02T.0105(c)(6). directly related environmental permits or certification applications are being prepared, have
been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and
sedimentation control plans, stormwater management plans, etc.).
6. Does this project include any sewer collection lines that are deemed "high -priority?"
Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer
positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer.
❑ Yes ® No ❑ NIA
➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location).
High priority lines shall be inspected by the permitteeor its representative at least once every six -months and inspections
documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit.
FORM: FTA 04-16 Page 4 of 5
X. CFRTIFICATIONS:
1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump_Slations
and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable?
® Yes ❑ No
If No, complete and submit the Variance/Altemative Design Request application (VADC 10-14) and supporting documents for
review. Approval of the request is required prior to submittal of the Fast Track Application and sul2aorting documents.
2. Professional Engineer's Certification:
I, 6 C, j ?4 UG 1D1 A1W 1 PE attest that this application for
(Professional Engineer's name from Application Item 111.1.)
has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications,
engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best
of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer
Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting
of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this
submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and
have judged it to be consistent with the proposed design.
NOTE In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation.
p►1t►►iiltapf lrrN�i�� ...._._._...
North Carolina Professional Engineer's seal, signature, and date: ..............
.`oQ;.•��ss y !y'o
O %
o- SEAL—
=0 5
',fill ti i'►►►► (S�u
3. Applicant's Certification per 15A NCAC 02T .0106(b):
I,
v
name & title from E
Item 1.3.)
that this application for
has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of
this application are not completed and that if all required supporting documentation and attachments are not included, this
application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -
discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties,
injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition
of this permit be violated. I also understand that if all required parts of this application package are not completed and that if
all required supporting information and attachments are not included, this application package will be returned to me as
incomplete.
NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation.
Signature:
Date: d ®Gf IX
NORM: FTA 04-16 Page 5 of
State of North Carolina
Department of Environment and Natural Resources
Division of Water Quality
Flow Tracking/Acceptance for Sewer Extension Permit Applications
(FTSE 06-13)
Project Applicant Name: Town of Fuquay-Varina
Project Name for which flow is being requested: Arnold Park
More than one FTSE may be required for a single project If the owner of the WWTP is not responsible for all pump
stations along the route of the proposed wastewater flow.
I. Complete this section only if you are the owner of the wastewater treatment plant.
a. WWTP Facility Name: North Harnett Regional WWTP
0
b. WWTP Facility Permit M NCO021636
AlI flows are in MGD _.
O
c. WWTP facility's permitted flow
2.60
c
d. Estimated obligated flow not yet tributary to the WWTP
0.564
E �
e. WWTP facility's actual avg. flow
1.204 _
b c1
.00
f. Total flow for this specific request
0.044
�—
g. Total actual and obligated flows to the facility
1.812
j
I Percent of permitted flow used
69.7%
11. Complete this section for each pump station you are responsible for along the route of th
proposed wastewater flow. IR
List pump stations located between the project connection point and the WWTP:
(A)
(13)
(C)
(D)=(B+C)
(E)=(A D)
Design
Obligated,
Pump
Average Daily
Approx.
Not Yet
Total Current
Station
Firm
Flow**
Current Avg,
Tributary
Flow Plus
(Name or
Capacity,*
(Firm / pt),
Daily FIow,
Daily FIow,
Obligated
Available
Number)
MGD
MGD
MGD
MGD
FIow
Capacity***
S. Oaks
no
1.263
0.505
0.219
0.156
0.375
0.130
* The Firm Capacity of any pump station is defined as the maximum pumped flow that
can be achieved with the largest pump taken out of service.
** Design Average Daily Flow is the firm capacity of the pump station divided by a peakiag
factor (pt) not less than 2.5.
*** A Planning Assessment Addendum shall be attached for each pump station located
between the project connection point and the WWTP where the Available Capacity is -� 0.
Page 1 of 7
FTSE 06-13
Certification Statement:
I Jay T. Meyers, PE, Public Utilities certify to the best of my knowledge that the addition of
Director
the volume of wastewater to he permitted in this project has been evaluated along the route to the
receiving wastewater treatment facility and that the flow from this project is not anticipated to
cause any capacity related sanitary sewer overflows or overburden any downstream pump station
en route to the receiving treatment plant under normal circumstances, given the implementation
of the planned improvements identified in the planning assessment where applicable. This
analysis has been performed in accordance with local established policies and procedures using
the best available data. This certification applies to those items listed above in Sections I and H
plus all attached planning assessment addendums for which I am the responsible party.
Signature of this form indicates acceptance of this wastewater flow.
l7�
Date
Page 2 of 7
FTSE 06-13
OF WArF9 State of North Carolina
Department of Environment and Natural Resources
vJ r Division of Water Quality
o -r Flow Tracking/Acceptance for Sewer Extension Permit Applications
(FTSE 06-13)
Project Applicant Name: Town of Fu ua-Varina
Project Name for which flow is being requested: Arnold Park
More than one ME may be required for a single project if the owner of the K WTP is not responsible for all pump
stations along the route oftheproposed waste►vaterflow
I. Complete this section only if you are the owner of the wastewater treatment plant.
a.
WWTP Facility Name: North Harnett Regional WWTP
b.
WWTP Facility Permit M NCO021636
A11 lows are in MGD
c.
WWTP facility's permitted flow
7.5 MGD
Fuquay Varina Allocated Flow
2.60 MGD
Lillington Allocated Flow
1.20 MGD
Angier Allocated Flow
1.008 MGD
d.
Estimated obligated flow not yet tributary to the WWTP
1.069 MGD
FV Obligated Flow NYT
0.564 MGD
Lillington Obligated Flow NYT
0.113 MGD
HC Obligated Flow NYT
0.326 MGD
Angier Obligated Flow NYT
0.066 MGD
e.
WWTP facility's actual avg. flow
3.776 MGD
FV Actual Flow
1.204 MGD
Lillington Actual Flow
0.616 MGD
HC Actual Flow
1.538 MGD
Angier Actual Flow
0.418 MGD
£
Total flow for this specific request
0.044 MGD
g.
Total actual and obligated flows to the facility
4.889 MGD
FV Actual Avg. + Obligated Flow
1.812 MGD
Lillington Actual Avg. + Obligated Flow
0.729 MGD
HC Actual Avg. + Obligated Flow
LW MGD
Angier Actual + Obligated Flow
0.484 MGD
h.
Percent of permitted flow used
65.18%
Page 1 of 6
FTSE 06-13
Il. Complete this section for each pump station you are responsible for along the route of this
proposed wastewater flow.
List pump stations located between the project connection point and the WWTP:
(A)
(B)
(C)
(D)=(B+C)
(E)=(A-D)
Design
Obligated,
Average Daily
Approx.
Not Yet
Total Current
Firm Flow**
Current Avg,
Tributary
Flow Pius
Pump Station Capacity,* (Firm I p0,
Daily Flow,
Daily Flow,
Obligated
Available
(Name or Number) MGD MGD
MGD
MGD
Flow
Capacity***
SLS 120 14.4 5.76
2.747
0.896
3.643
2.117
* The Firm Capacity of any pump station is defined as the maximum pumped flow that
can be achieved with the largest pump taken out of service.
** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking
factor (pf) not less than 2.5.
*** A Planning Assessment Addendum shall be attached for each pump station located
between the project connection point and the WWTP where the Available Capacity is < 0.
III.
Certification Statement:
I Steve Ward — Director of Public Utilities certify to the best of my knowledge that the addition of
the volume of wastewater to be permitted in this project has been evaluated along the route to the
receiving wastewater treatment facility and that the flow from this project is not anticipated to
cause any capacity related sanitary sewer overflows or overburden any downstream pump station
en route to the receiving treatment plant under normal circumstances, given the implementation of
the planned improvements identified in the planning assessment where applicable. This analysis
has been performed in accordance with local established policies and procedures using the best
available data. This certification applies to those items listed above in Sections I and II plus all
attached planning assessment addendums for which I am the responsible party. Signature of this
form indicates acceptance of thAastewater flow.
to -rY=! ,?
Signing Official Signature Dare
FTSE PLANNING ASSESSMENT ADDENDUM (PAA)
Submit a planning assessment addendum for each pump station listed in Section II where Available
Capacity is < 0.
Pump Station (Name or Number):
Given that:
Page 2 of 6
FTSE 06-13
i
e
N
k\{
r
r
NYC
"gym
amb
KENNJETH
CR K
CID
H
PARK PREPARED FOR-
ARNOLD
WiL80N PROPERTIES, LLC
FUQUAY-VARINA, WAKE COUNTY, NORTH CAROLINA
SEWER PERMIT DATE : 02/05/2018
USGS QUAD 'FUQUAY-VARINA' S&N FIRM CERT. 0: C-1875
SPAt TL,DJ�TG & PROJECT ENGINEER:
THOMAS J. SPAULDING
S4& NORM, PA PROJECT CARD DESIGNER:
Design Consultants BD
972 Trinity Road
Raleigh, Norih Carolina 27607 PROJECT SURVEYOR:
Phone (919) 135�-7990 Fax (9f9) 854-7925 MAULDIN WATKINS
T'r ,, I ` ♦ - T" 1t2J 1-G11 _ i] lug+'; `��
i i � � �`♦/ 1 -. � t'..k' r Y� � �-'"?\ � !._ � } TT� -j`-_ `T--���7 �+1 r--_._ }�-� � -i
�. t' _,
i `F-
i^..{Ll
rY+Ti Y"1 l���J F--i
_ -, -- C�-.i _1 t-�
,�,; C�� ;' I `-_ z , i �� E : JUDD PARKWAY --a
`_.-_,'Yi''� �� Y•.� f_``yi_t' ` 5 , }! -'T» "--------------- :..^_J
III
-," �-------SOUTH PART(
RECREATIONAL y
�._-_ i.• / ��-,:.J 4; Y '�`. YY �� f
`♦ ixY`,_�♦(�ii-_-�_ •.. ' A`r.'i�.'`.�f's,` ��`` r`' Y�,Y,',x r• • /,YY �'f,�Y'/rx`'c`,ry''.ii i'r�Xi'�.� �i i' i�,.' •f� �` yY `,ir;.��/Y" ,`,,'`- � r•y�I f FACIL Ti l S Q
.tJ.- _.f._r___.J�__ri�_TT�_�I T_T__I_Tr
r.F--iSOUTHER
OAKSx6D
-------"_-----„------- r
xx
'oJ
'� Y',' >,Y a ,�' K ',a. `♦ 1 r I 1 r 1` y OPEN ' '__'_- F-'•.- #^F+Jr �r�rt
SPACE
1 I TTTT •-L �..1i YY''. �` Y�; `, �y :� -_t i��81Q, I, -_ ' _ �_-•__» !I 1 TTT'T
1 I
_A r SITE
k---� F-i .v'. , k.' .� . '1 �_ _ CAXRUIGE - y'1 r^` /�•( r
^ KENNETH
i��'���/♦ CREEK y,l �'�_�'=7 -�-�'' ,•��``�^� i `_-__
✓ Y IT �T Y WCPSS SCHOOLS SITE
, r
CAROLL 0 RO
JOHNSON A
ENVIRONMENTAL
I , ,
f_______________ THEYSMILL
v CD
1 , JF. ,�'.� . r I - I _ i FUTURE RYAN PLACEo
`
it I I •y 1 . r`�F
J
T---T r ^__ 1 1♦ , -T- -
�
i I i r r 1 r FUTURE
Y i
_ -� r , 1 t' f i HIGHLAND FOREST'`
VICINITY MAP
1" = 500'
FORM WSCAS-12/07 _0 d WAr$9?
WATERSHED CLASSIFICATION ATTACHMENT
o -c
FOR SEWER SYSTEMS
Applicant Nam
Pro ect Name
Town of Fuquay-Varina
Arnold Park Development
Professional Engineer Name
Engineering Firm Name
Thomas Spaulding
Spaulding & Norris
Raleigh Regional O
ivality
xce
Location
ID
Name of Waterbody'
Coun
River
Basin
Waterbody Stream
index No.
Waterbody
Classification
1
Kenneth Creek
Wake
Cape Fear
18-16-1-(1)
C
I If unnamed, indicate "unnamed tributary to X", where X is the named waterbody to which the unnamed tributary joins.
! certify that as a Registered Professional Engineer in the State of
North Carolina that l have diligently followed the Division's instructions
for classifying waterbodies and that the above classifications are
inclusive of the stated project, complete and correct to the best of my
knowledge and belief.
PE Seal, Signature and Date
*** END OF FORM WSCAS-12107 ***
FORM: WSCAS-12107 Page 1 of 1
S4&7,-
_zV
Project Narrative:
SPAULDING & NURRIS PA
Planning • Civil Engineering
Arnold Park
The proposed Arnold Park Development is located at 202 Wagstaff Road, Fuquay -
Varina, NC 27526. The site is approximately 1,5001f west of the intersection of USHWY
401 and Wagstaff Road. The project includes infrastructure construction 80 Townhomes
and 12 Single Family Units equaling 92 total residential units. The homes will be served
by 2,0671f of PVC sewer mains. The sewer mains will connect to an existing manhole in
the adjacent Carriage Heights Subdivision. The proposed sewer lines will be public mains
with a proposed flow of 27,600 GPD. Please see enclosed Utility Plan.
Project Schedule:
Construction of Arnold Park is anticipated to begin in November of 20I8. Infrastructure
construction is estimated to be complete by February 2019. Complete build -out of the
phase and issuance of certificates of occupancy for all lots expected by January 2021.
NC Dept efEnvironmental Quality
OCT 2 2 2ni8
Raleigh Regional Office
S�CVC SPAULDING & NGRRIS, PA
Planning • Civil EngineeringIV
a
TRANSMITTAL
To:
NCDENR- Water Quality
Raleigh Regional Office
3800 Barrett Drive
Raleigh, NC 276og
Sending.
® Attached
❑ Shop Drawings
❑ Copy of Letter
❑ TotalOuantity
Date: 10/19/2o18
Attention: Jason Robinson
a
Job Number: 894 A
Re: Arnold Park Subdivision 2
Fuquay-Varina, Wake County
Fast -Track Application PKG
❑ Under Separate Cover via:
❑ Prints ❑ Plans ❑ Other:
❑ Change Order ❑ Samples
❑ Reuroducible ❑ Specification
Copies
Date
Description
1
10-19-2018
S480.00 Review Fee
2
9-21-2018
Project Narrative, Cover Letter
2
10-04-2018
Fast Track Application for Gravity Sewers
2
10-15-2018
FTSE (Fuquay-Varina and Harnett County)
2
8-14-2018
USGS Map (Color)
2
8-14-2018
Vicinity Map
2
10-18-2018
1 Watershed Classification Form
Transmitted for:
® Your use
❑ As Requested
❑ Review and Comment
Comments:
Mr. Robinson,
❑ Approved as Submitted
❑ Approved as Noted
❑ Returned for Corrections
❑ Copies for Approval
❑ Distribution Copies
❑ Corrected Prints
Please see enclosed Fast Track Application (FTA 10-14) and accompanying documents for review
And approval. Please contactme with any questions. Thank you.
Copy to:
Tom Spaulding, PE
Phone: (919) 854-7990 • Fax: (919) 854-7925 9 972 Trinity Road 9 Raleigh. North Carolina 27607
F
Robinson, Jason
From: Jay T. Meyers, PE <jmeyers@fuquay-varina.org>
Sent: Thursday, December 13, 201811:20 AM
To: Robinson, Jason; Tom Spaulding; brian@spauldingnorris.com
Cc: Cashion, Ted; Deck, Erin M.
Subject: Re: [External] RE: Arnold Park Sewer Extension Application.
you have my permission and thank you
E _.. --
Jay T. Meyers, PE I Public Utilities Director
Town of Fuquay-Varina
401 Old Honeycutt Road
Fuquay-Varina, NC 27526
me ers fu ua-varina.or
919-567-3911
www.fuquay-varina.org
From: Robinson, Jason cjason.t.robinson@ncdenr.gov>
Sent: Thursday, December 13, 201810:15 AM
To: Tom Spaulding; Jay T. Meyers, PE; brian@spauldingnorris.com
Cc: Cashion, Ted; Deck, Erin M
Subject: RE: [External] RE: Arnold Park Sewer Extension Application.
Thanks Tom,
Since Mr. Meyers is the permittee, we'll need his permission to make the revisions to the permit proposed in
items 2-4 in my email below.
-Jason
------------
Jason T. Robinson, P.E.
Raleigh Regional Office
Water Quality Regional Operations
Division of Water Resources, DEQ
919-791-4200
"Subscribe to Collection System & Sewer Permitting Updates"
Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to
third parties.
From: Torn Spaulding <tom@spauldingnorris.com>
Sent: Wednesday, December 12, 2018 5:42 PM
To: Robinson, Jason <jason.t.robinson@ncdenr.gov>; jmeyers@Fuquay-varina.org;
brian@spauldingnorris.com
Cc: Cashion, Ted <ted.cashion@ncdenr.gov>; Deck, Erin M <erin.deck@ncdenr.gov>
Subject: [External] RE: Arnold Park Sewer Extension Application.
Jason, we will work on the applications irk the future. I am okay with making the revisions and the flow
amount is 44,160 GPD.
Thank you and Sorry for the confusion.
Tom
Tom Spaulding, PE, CFM
Principal Engineer
ORRIS. PA
972 Trinity Rd
Raleigh, NC 27607
Phone: (919) 854-7990
Fax: (919) 854-7925
From: Robinson, Jason <lason.t.robi_nson@ncdenr.eov>
Sent: Wednesday, December 12, 2018 11:59 AM
To: imeyers@Fuauav-varina.ors; tom(@spauldingnorris.com
Cc: Cashion, Ted <ted.cash ion ncdenr. ov>; Deck, Erin M <erin.deck@ncdenr.eov>
Subject: Arnold Park Sewer Extension Application.
We are reviewing the referenced sewer extension application and have the following comments/questions:
1. There are multiple cross -outs and rewrites on the application. In the future, if revisions are made to
the application before submittal, please create a new application to be submitted.
2. Section IVA states that the wastewater will go to the Harnett County WWTP. I believe the actual name
is the North Harnett Regional WWTP. With your permission, we'll make this change to the
application.
3. Section IV.1 also states the permit number for the receiving WWTP is WQ007066, which is a land
application permit, and not the WWTP permit #. I think the correct number is NC0021636. With your
aermission, we will make this change to the application.
4. The narratives states the proposed flow is 27,600 GPD, but the application has this number crossed -out
and 44,160 written -in. Please confirm that this application is requesting 44,160 GPD.
Thanks,
Jason
------------
Jason T. Robinson, P.E.
Raleigh Regional Office
Water Quality Regional Operations
Division of Water Resources, DEQ
919-791-4200
"Subscribe to Collection System & Sewer Permitting Updates"
6 mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to
third parties.