Loading...
HomeMy WebLinkAboutNC0021644_Compliance Evaluation Inspection_20181212ROYCOOPER Gaauarxon miciiAEL S_ REGAN Sa��st�z� LPSTDA CULPEPPER Tr:ta hn Diingewr. John P Craft Town of LaGrange PO Box 368 La Grange, NC 28551 NORTH CAROLINA December 12, 2018 SUBJECT: Compliance Inspection Report La Grange WWTP NPDES WW Permit No. NCO021644 Lenoir County Dear Mr. Craft: RECEIVE /DE' WR REGEI ip 14� �1 Water Resources Permitting Section �". ��.atictcx �v—•• . The North Carolina -Division-of Water Resources conducted an inspection of the La Grange WWTP on. 12/10/2018. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0021644. The findings and comments noted during this inspection are provided in- the enclosed copy of the inspection report entitled "Compliance Inspection Report". Please respond in writing to this office within 10 days of your receipt of this letter regarding -your plans or measures to be taken to address the,following issue: • Flow, in conduit or thru treatment plant exceeds .750 MGD permitted capacity If you should have any questions, please do not hesitate to contact Stewart White with the Water Quality Regional Operations Section in the Washington Regional Office at 252-948-3940 or via email at stewart.white@ncdenr.gov. Sincerely, Stewart White, Environmental Specialist I Water Quality Regional Operations Section Washington .Regional Office Division of Water Resources, NCDEQ North Carolina Department of Environmental Quality I Division of Water Resources 943 Washington Square Mall, Washington, NC 27889 252-946-6481 ATTACHMENTS n Cc: WQS Washington Regional Office - Enforcement File NPDES Compliance/Enforcement Unit - Enforcement File -. V-IFw Q North Carolina Department of Environmental Quality I Division of Water Resources 943 Washington Square Mall, Washington, NC 27889 252-946-6481 United States Environmental. Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 15 I 3 I N00021644 I11 12 18/12/10 _ 17 18 ,, 19 1 G 20. Ll . 21111111 111111111111111 I I Iliiii I I I I I I I I I I I f6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 67 70 L_I �, � 71 L 72 L N J 73 L I ]74- 751 I I I 1 I �80 LJ I Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date P.OTW name and NPDES permit Number) 01:25PM 18/12110 13I07/01 La Grange WWTP 700 E King St Exit Time/Date Permit Expiration Date La Grange NC 285510368 02:50PM 18/12/10 18/01/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data James Wesley Sutton/ORC/252-566-3295/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted John P Craft, PO Box 368 La Grange NC 28551/Town Manager/252-566-3186/2525662201 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports . Sludge Handling Disposal Facility Site Review Pretreatment Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and'Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Stewart White WARO WQ//252-948-3940/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type I 31 NCO021644 I11 121 18/12/10 117 18 ICI Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessaryy ORC Wesley Sutton was present for inspection. ORC stated that they have recieved approximately 80 inches of rainfall this year. The WWTP is -having some issues meeting flow limits. The Effluent coming out of the plant looks good. Reviewed eDMR's for August 2018 and October 2018. Records were neatly kept and organized. Page# Permit NCO021644 Owner - Facility: La Grange WWTP Inspection Date: 12/10/2018 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ® ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable M ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ❑ application? Is the facility as described in the permit? ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ❑ ❑ ❑ Comment: Permit Expired January 31, 2018. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ❑ ❑ ❑ Is all required information readily available, complete and current? 0 ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? ❑ ❑ ❑ Is the chain -of -custody complete? ❑ ❑ ❑ Dates, times and location of sampling ❑ Name of individual performing the sampling ❑ Results of analysis and calibration ❑ Dates of analysis ❑ Name of person performing analyses ❑ Transported COCs ❑ Are DMRs complete: do they include all permit parameters? ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ M ❑ on each shift? Is the ORC visitation log available and current? M ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? 0 ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? i ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? M ❑ ❑ ❑ Page# 3 Permit: NC0021644 Owner - Facility: La Grange wVVfP Inspection Date: 12/10/201 S Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Facility has copy of previous year's Annual Report on file for review? N ❑ ❑ ❑ Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? ❑ ❑ ❑ If. effluent (diffuser pipes are required) are they operating properly? ❑ ❑ M ❑ Comment: Flow Measurement - Influent Yes No NA NE # Is flow meter used for reporting? ❑ M ❑ ❑ Is flow meter calibrated annually? 0 ❑ ❑ ❑ Is the flow meter operational? N ❑ ❑ ❑ . (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ M ❑ . Comment: Influent Meter calibrated 7/3/18 Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? E ❑ ❑ ❑ Is flow meter calibrated annually? ❑ ❑ ❑ Is the flow meter operational? ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ N ❑ Comment: Effluent Meter calibrated 7/3/18 Aerobic Digester Yes No NA NE Is the capacity adequate? E ❑ ❑ ❑ Is the mixing adequate? 0 ❑ ❑ ❑ Is the site free of excessive foaming in the tank? E ❑ ❑ ❑ # Is the odor acceptable? 0 ❑ ❑ ❑ # Is tankage available for properly waste sludge? E ❑ ❑ ❑ Comment: Synagrow hauls once / year. Pump Station - Influent. Yes No NA NE Is the pump wet well free of bypass lines or structures? 0 ❑ ❑ ❑ Page# 4 Permit: NC0021644 Owner - Facility: La Grange WWTP Inspection Date: 12/10/2016 Inspection Type: Compliance Evaluation Pump Station - Influent Yes No NA NE Is the wet well free of excessive grease? ■ ❑ ❑ ❑ Are all pumps present? ■ ❑ ❑ ❑ Are all,pumps operable? ■ ❑ ❑ ❑ Are float controls operable? ❑ ❑ ❑ ■ Is SCADA telemetry available and operational? ❑ . ❑ ❑ IS audible and visual alarm available and operational? Comment: SCADA down since June per ORC Bar Screens _ Yes No NA NE Type of bar screen a.Manual ■ bNechanical ■ Are the bars adequately screening debris? ■ ❑ ❑ ❑ Is the screen free of excessive debris? ■ ❑ ❑ ❑ Is disposal of screening in compliance? ■ ❑ ❑ ❑ Is the unit in good condition? ■ ❑ ❑ ❑ Comment: Grit Removal Yes No NA NE Type of grit removal a.Manual ❑ b.Mechanical ■ Is the grit free of excessive organic matter,? ■ ❑ ❑ ❑ Is the grit free of excessive odor? ■ El 0 ❑ # Is disposal of grit in compliance? ■ ❑ ❑ ❑ Comment.- Garbage Truck picks up containers Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? ■ ❑, ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? ❑ ❑ ❑ Are weirs level? ❑ ❑ ❑ Is the site free of weir blockage? ■ ❑ ❑ ❑ Is the site free of evidence of short-circuiting? ■ ❑ ❑ ❑ Page# 5 Owner - Facility: La Grange VNNTP Permit: NC0021644 Inspection Type: Compliance Evaluation Inspection Date: 12I10/2018 Yes No NA NE Secondary Clarifier Is scum removal adequate? M El❑ ❑ Is the site free of excessive floating sludge? • ❑ ❑ ❑ Is the drive unit operational? . M El ❑ ❑ Is the return rate acceptable (low turbulence)? El ❑ ❑ -Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately '/< of the sidewall depth) ❑ ❑ ❑ M Comment: Yes No NA NE Oxidation Ditches ■ ❑ ❑ ❑ Are the aerators operational? ■ ❑ ❑ ❑ Are the aerators free of excessive solids build up? # Is the foam the proper color for the treatment process? M. ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? N ❑ ❑ ❑ ■ ❑ ❑ ❑ Is the DO level acceptable? ❑ ❑ Are settleometer results acceptable (> 30 minutes)? N ❑ ❑ ❑ Is the DO level acceptable?(1.0 to 3.0 mg/1) Are settelometer results acceptable?(400 to 800 ml/I in 30 minutes) ❑ ❑ ❑ 0 Comnrient: Filtration (High Rate Tertiary) Yes No NA NE Type of operation: ❑ El 110 Is the filter media present? ❑ ❑ ❑ ■ Is the filter surface free of clogging? ❑ ❑ ❑ ■ Is the filter free of growth? ■ ❑ ❑ ❑ Is the air scour operational? ❑ ❑ ❑ ■ Is the scouring acceptable? ❑ ❑ ❑ M Is the clear well free of excessive solids 'and filter media? Comment: Effluent looks good coming out of filter. Disinfection -Gas Yes No NA NE Are cylinders secured adequately? ❑ ❑ ❑ El ❑ Are cylinders protected from direct sunlight? 0 ❑ ❑ Is there adequate reserve supply of disinfectant? Page# 6 Permit: NCO021644 Owner - Facility: La Grange WWrP Inspection Date: 12/10/2018 Inspection Type: Compliance Evaluation Disinfection -Gas Yes No NA NE Is the level of chlorine residual acceptable? ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? 0 ❑ ❑ ❑ Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? ❑ ❑ N ❑ If yes, then is there a Risk Management Plan on site? ❑ ❑ N ❑ If yes, then what is the EPA twelve digit ID Number? (1000- - ) If yes, then when was the RMP last updated? Comment: Uses Sulfur Dioxide for de -chlorination. Standby Power Yes No NA NE Is automatically activated standby power available? E ❑ ❑ ❑ Is the generator tested by interrupting primary power source? 0 ❑ ❑ ❑ Is the generator tested under load? ❑ ❑ ❑ Was generator tested & operational during the inspection? ❑ 0 ❑ ❑ Do the generator(s) have adequate capacity to operate the entire wastewater site? 0 ❑ ❑ ❑ Is there an emergency agreement with a fuel vendor for extended run on back-up power? ❑ ❑ ❑ N Is the generator fuel level monitored? ❑ ❑ ❑ Comment: Generator comes on every Monday 10am Pumps-RASMAS Yes No NA NE Are pumps in place? ❑ ❑ ❑ Are pumps operational? 0 ❑ ❑ ❑ Are there adequate spare parts and supplies on site? 0 ❑ ❑ ❑ Comment: Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? N ❑ ❑ ❑ # Is the -facility using a contract lab? N ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ ❑ Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? ❑ ❑ M ❑ Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? ❑ ❑ N ❑ Page# 7 Permit: NC0021644 Inspection Date: 12/10/2018 Laboratory Owner - Faciliity: La Grange VV TP Inspection Type: Compliance Evaluation Comment: Lab was clean. The facility uses Environment 1, Inc. Yes No NA NE Page#