Loading...
HomeMy WebLinkAboutWQ0040526_Application (FTSE)_20181025' State of North Carolina Department of Environmental Quality 5 DW.R Division of Water Resources 15A NCAC 02T.0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Dlvlslon of Water Resources FTA 04-I6 & SUPPORTING DOCUMENTATION Application Number: v d O �J S . (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Johnston County Public Utilities (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ IndividuaI ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ® Municipal ❑ Other 3. Signature authority's name: Chandra Farmer. PE per 15A NCAC 02!-.Q 06[bl Title: Director of Public Utilities 4. Applicant's mailing address: Post Office Box 2263 City: Smithfield State: NC Zip: 27577- 4` c 5. Applicant's contact information: °O Phone number:919 209-8333 Email Address: chandra.farmer 'ohnstonne.com O 5�- II. PROJECT INFORMATION: .> -. 1. Project name: Aspen Point 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project ce- If a modification, provide the existing permit number: WQ00and issued date: If new construction but part of a master plan, provide the existing permit number: WQ0038462 3. County where project is located: Johnston 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.6160` Longitude: -78.5630` 5. Parcel ID (if applicable): 06EO2065 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: I . Professional Engineer: Jegy T. Dalton(` License Number: 016282 Firm: Daiton Enaineering and Associates P.A. Mailing address: Post Office Box 426 City: Clayton State: NC Zip: 27528 - Phone number:919 550-4740 Email Address: 'dalton daltonen ineerin .com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Johnston Coun Regional Central Treament Plant Permit Number: NCO030716 Owner Name: Johnston Coun V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): W W 0038462 Downstream (Receiving) Sewer Size: 8 inch System Wide Collection System Permit Number(s) (if applicable): WQCS00060 Owner Name(s): Johnston County FORM: FTA 04-16 Vl. GENERAL REQUIREMENTS 1. if the Applicant is a Privately -Owned Public l itilit, , has a t= ertiticate of Public Convenience and Necessity been attached? ❑ Yes [—]No ®N:A 2. If the Applicant is a Developer of lots to be sold, has a Devclop5r'a Operatinn2}1 f «regiment F R T: DEVI been attached? ❑ Yes ❑No ®N.:A 3. If the Applicant is a HomefProe v Owners' A sociation has an O ierational Agreement tFORM: HOA) been attached? ❑ Yes ❑No ®N A 4, Origin of wastewater_ (check all that apply): ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Residential Leased ❑ Retail with food preparation?service ❑ School I preschool / day care ❑ Medical! dental: veterinary facilities ❑ Food and drink facilities ❑ Church ❑ Businesses! offices..' factories ❑ Nursing Home 5. Nature of waste%kater : 100 °-o Domestic'Commercial *f Commercial ❑ Car Wash Hotel and/or Motels ® Swimming Pool+Clubhouse ❑ Swimming Pool.Tilter Backwash ❑ Other (Explain in Attachment) I6 Industrial (See 15A NCAC 021'.0 103f 29j) ;Is there a Pretreatment Program in effect`' ❑ Yes ❑ No 6. Has a flow reduction been approved under 15A NCAC U? T .01 14LO? ® Yes ❑ No If yesProvide a copy of flow reduction a roval letter 7_ Summarize wastewater generated by project - Establishment Type (see 02T.01140 Daily Design Flow "h No. of Units Flow 1-2 BR, multi -family residential units 340 gal/day 160 38,400 GAD 3 -BR, multi -family residential units 360 gal/day 36 12,960 GPD Cabana and Pool 10 gal/day/person 50 avg peak 500 GPD gall GPD Bail GPD gall GPD Total 51,860 GPD �vl a See 15A NCAC 02TAI-I)_(dli lelt I ) and _h (2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling: proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G,S. 42.E -4F, b Per I5A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy 7oroNtion patterns, and other measured data. 8. Wastewater generated by project; 51.864 GPD (per ,15A NCAC 02.'f .01 14 .- Do not include future flows or previously permitted allocations If permitted flog is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number. ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Fxplain)-. — FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewersl: I . Summarize gravity sewer to be permitted: Size (inches) I Length (feet) I Material 1 8" I 2,565 I PVC ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria Z Section HI contains information related to minimum slopes for gravity sewer(s) Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC Vill. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T.0305 & MDC (Pump Stations/Force Mainsl: COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT I . Pump station number or name: 2, Approximate Coordinates (Decimal Degrees): Latitude: _ . Longitude: 3. Design flow of the pump station: z millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15ANCAC03T..0305fh)€€1: ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(8)_ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day D Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): Z It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. > If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 lX. SETBACKS & SEPARATIONS — (02[3.0200 & 15A NCAC 02T .0305(1)): 1. Does the project comply with all separations found in 15A NCAA' 02T .0305(# &W D I5A NCAC 02T.0305( contains minimum se arations that shall be rovided Far sewers stems- ® Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer includin in benched trenches) 18 inches Water mains (horizontal) I0 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS -1 waters of Class I or Class 11 im ounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS -I or WS -V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item IX.2) 50 feet **Any other stream, Iake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts oft feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools I0 feet Final earth grade (vertical) 36 inches D15A_NCAC 02T.0305f contains alternatives where separations in 02T.0305(f1 cannot be achieved. **Stream classifications can be identified using the Division's TUC Surfine_Water Classificstions weljpp D If noncompliance with 02T.03 5 or see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes [:]No See the Division's draft separation requirements for situations where separation cannot be meet No variance is required if the alternative design criteria specified is utilized in design and construction As built documents should reference the location of areas effected 3. Does the project comply with all setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No This would include Trout Buffered Streams per 15A NCAC 213.0202 4. Does the project comply with an individual 404 Permit or any 401 Certifications? ® Yes ❑ No z Wetland -related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters s Information can be obtained from the 401& Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits'certifications)? ® Yes ❑ No Per 15A NCAC 02T,0I05(c)f6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high-priority?" Per 15A NCAC 02T.0402. "high-priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No :- If yes, include an attachment with details for each line, including type (aerial Iine, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the. Permitting of Pum Stations an ,_Force `plains (latest version and the Gravity Sewer Minimum Desmon Criteria f latcsr version as applicable? ® Yes ❑ No If No, complete and submit the VariancefAlternative Design Request application (VADC 10-14) and supporting documents for review. Anproval of the reciuest is rc uired prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: M s name from Application Item III.1.) that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which�ey include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): (Signature Authority's name & air from Application Item 1.3.) attest that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. 1 also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-31215.6_13, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: �� Date: FORM: FTA 04-16 Page 5 of 5 Dalton Engineering and Associates, P. A.-- 10125/2018 . LETTER OF TRANSMITTAL TO: N.C.D.E.Q. - Raleigh Regional Office ATTENTION: DATE: 1012512018 INC Dept of Environmental Alia] ily OCT 2 5 2018 Meigh Regional Affilge- Jason Robinson REFERENCE: Aspen Point We are sending You: PLANS X CHECK SPECIFICATIONS COPY OF LETTER REVISED PLANS X APPLICATIONS PERMITS X OTHER Copies Date Dw . # Description 2 ea. Fast -Track Application Form, Cover Letter, Flow Tracking 1 Acceptance Form, USGS Site Map 1 Application Fee: $480.00 Ck#15101 These are transmitted as checked below: X For Approval Revisions As Requested As Requested Return Corrected Copies Review & Comment Make Corrections Needed For Your Use Other COMMENTS THANK OU Jerry Dalton Dalton Engineering and Associates, P.A. Dalton Engineering and Associates, P.A. 10/25/18 NCDEQ FAST TRACK APPLICATION ( FTA 04-16 ) Sub. Aspen Point Cleveland Township Johnston County, North Carolina Owner: United Developer, Inc. 2939 Breezewood Ave Ste 201 Fayetteville, NC 28303 NC Dept of Environmental Quality OCT 2 " 7018 Raleigh Regional Office United Developers, Inc. is proposing to develop Aspen Point Development, which is located in the Cleveland Township in northwest Johnston County. The project site is adjacent to Hwy 42 West and Interstate 40. The project includes the development of 196 multi -family apartments, water, sewer and storm drainage facilities. It also includes a pool and clubhouse. The project will consist of the construction of a roadway that will provide access to the property with storm drainage and curb and gutter, sidewalk, water system extension, and a gravity sanitary sewer system extension. If there are any questions or comments, please do not hesitate to call. Thank you. erry D On 446 East Main Street — P.O. Box 426 .. Clayton, NC 27528 � (919) 550-4740/Fax (919) 550-4741 I- o, rr C> r1 Q N a 0 z a O 1.0 m F OW N C7,R. oo� z o o� cv (11 CD p p4 fit} t+ to o 0 0 CL, o% } oO %0 oa .y q o %0 C-3 cqO m 00 Co¢ N Chi O 6C_ O�Nr C,l10 C�JrNY 41 Ol Cf 0! C1 Ol d Z O E W m H N U) 0 m CO m r- m z N M V V L L L m R. �d„ L iL O t z Z 'O N L 1- 'G 'O 'O 'a V O Q Q N as cj N N Q 0 M 0 J w LU ce J zg •W co T. J o g u Z to Q Q n v State of North Carolina Department of Environment and Natural Resources i Division of Water Resources Division Of Water lieSourie9 Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 08-13) Project Applicant Name: Johnston County Project Name for which flow is being requested: Aspen Point More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Central Johnston County WWTP b. WWTP Facility Permit #: NC0030716 All flows are in MGD c. WWTP facility's permitted flow 9.5 d. Estimated obligated flow not yet tributary to the WWTP 2.2979 + 0.34 Clayton Purchase e. WWTP facility's actual avg. flow 5.4020 (previously reserved 32,960) f Total flow for this specific request 0.5186 g. Total actual and obligated flows to the facility 2.3168 h. Percent of permitted flow used 84.8% H. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (B) (L) (A) Obligated, Design Pump Not Yet Average Daily Station Firm Flow** (Name or Capacity,* (Firm / p f), Number) MGD MGD New Swift Creek* 1.764 0.706 Josephine 3.384 1.354 (B) (L) (D)=(B+C) (E)=(A-D) Obligated, Approx. Not Yet Total Current Current Avg. Tributary Flow Plus Daily Flow, Daily Flow, Obligated Available MGD MGD Flow Capacity*** 0.595 0.5251 0.5165 0.1895 1.1200 0.2336 Lanfill EQ 1.930 1.672 0.672 0.6951 1.3669 0.3049 *WQOo39606 Under const. * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pt) not less than 2.5. Page 1 of 7 FTSE 08-13 *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. III. Certification Statement: k I Chandra C. Fanner, P.E. certify to the best of my knowledge that the addition of the volume ofwastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and H plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. Signing Official Signature Page 2 of 7 FTSE 08-13