Loading...
HomeMy WebLinkAboutWQ0040512_Application (FTSE)_20181025State of North Carolina Department of Environmental Quality DWR Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number&Q0A 0 (ta be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: I. Applicant's name: Durham County (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ IndividuaI ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ® State, -County ❑ Municipal ❑ Other 3. Signature authority's name: Stephanie Brixev per 15A NCAC 02T .0106(b) Title: Deputy Director;' POTW Director, 4. Applicant's mailing address: 5926 Highway 55 East U City: Durham State: NC Zip: 27713 Or C 5. Applicant's contact information: a� Phone number. (919) 560-9034 Email Address: sbrixeyadconc.g_ov c o tia� .a II. PROJECT INFORMATION: C.) 94 W U I . Project name: Lumley Road - Townhomes •� 2. Application/Projectstatps: ®Proposed (New Permit) El Existing Permit/Project ai A If a modification, provide the existing permit number: WQ00 and issued date: U Z If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Durham 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.923688' Longitude:-78.808568 5. Parcel ID (if applicable): 222558 (or Parcel ID to closest downstream sewer) Ill. CONSULTANT INFORMATION: 1. Professional Engineer: Preston Rooster License Number: 35003 Firm: Coulter Jewell Thames, PA Mailing address: l I I W Main Street City: Durham State: NC zip: 27701- Phone number: (919) 682-0368 Email Address: moyster(&citpa.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Triangle Wastewater Treatment Plant Permit Number: NCO026051 Owner Name: Durham County V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQBuilt Yr. 2000 Downstream (Receiving) Sewer Size: 8 inch Sys!Sn ,j Wide Collection System Permit Number(s) (if applicable): WQCS00038 Owner Name(s): Durham County FORM: FTA 04-16 Pagel of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes [:]No ®NIA 2. If the Applicant is a Developer of lots to be sold, has a Develup!r 's Ppl rational A�,,reemew (FORM: DEV) been attached? ❑ Yes [-]No EN. -'A 3. If the Applicant is a Home,'I'ronerty Owners' As.%)ci�Lion, has an OperalionaI Agreement (FORM: H{]A) been attached? ❑ Yes ❑No ON.A 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ RetaiI (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School/ preschool / day care ❑ Medical / dental J veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses offices.-' factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % DomesticlCommercial 0 % Commercial 0 % Industrial (Set 15A NCAC 02T ,0103(20)) 1 1, Is there a Pretreatment Program in effect? ❑ Yes [:]No 6. Hasa flow reduction been approved under 15A NCAC 02_T _0114(1)? [:]Yes ®No D If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T Daily Design Flow',b No. of Units Flow RESIDENTIAL 360 gat/DAY 93 33,480 GPD gall GPD gall GPD gall GPD gat/ GPD gat/ GPD Total 33,480 GPD a See l5A NCAC 02T .0l 14(b), (d),_(e)(I) and e 2 for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42AA). b Per 15A NCAC 02T Al 14(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flo�v_d�$,Qwater using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by projects GPD (per 15A NCAC 02T .0114) D Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 1,081 PVC 8 825 / DIP ;\" V� )�- Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria Section III contains information related to minimum slopes for gravity sewer(s) >r Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .0305L11j( is ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B)_ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day D Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. > If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage_ FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T d1305(f)): 1. Does the project comply with all separations found in 15A.NCAC 02T .0305(f) & tg) ➢ 15A NCAC 02T.0305(f) contains minimum separations that shall he nmvided fnr sewer systems, ® Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item IX.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade vertical 36 inches ➢ 15.A NCAC 02T.03Q5W contains alternatives where separations in 02T.03051 fl cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classif ns web ➢ If noncompliance with 02�1�.f1305 o or (a), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes ❑ No ❑ N. A ➢ See the Division's draft separation requirements for situations where separation cannot be meet D No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No ❑ N A ➢ This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 &. Buffer Permitting` Branch 5. Does project comply with 15A NCAC 0 T.0105 c 6) (additional permits/certifications)? ® Yes ❑ No Per 15A NC:_'1C 02T.0105tu 6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 021.9402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ MA ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: I. Does the submitted system comply with 15A NCAC 02T, the Minimum. Design Criteria for the Permitting of Pump Stations and Force Mains (latest vcnion), and the C',mvity Sewer Minimum Design Criteria f latest version l as applicable? ® Yes ❑ No If No, complete and submit the Variance?Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is re uired prior to submittal of the Fast Track Application and suoportinE documents. 2. Professional Engineer's Certification: gg?t �— _ .._ _attest that this application for (Professional Engineer's name from Application Item II1.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE - In accordance with General Statutes I43-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. ............... ----,;.,.,..-----.-.�.,.'....._.. ........... North Carolina Professional Engineer's seal, signature, and date: I \A CARD SEAL 35 N.g.RO��`�. .................•....... .•........ •......... _ 3. Applicant's Certification per 15A NCAC 02T .0106(b): I, tt_ r lST10 attest that this application for (Signature Authority's�n me & title from A lication Item .3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: -L.A Date: M 13) ao,6i FORM: FTA 04-16 Page 5 of 5 Coulter Jewell thames, PA M_6_IN_OFF ICE ... WEST MAIN STREET OURHAM, NC 27701 p919 662 0 36 6 1919 666 5646 Planning for the Future October 22, 2018 North Carolina Department of Environmental Quality Division of Water Resources Raleigh Regional Office 1628 Mail Service Center Raleigh, NC 27699-1628 Re: Lumley Road Townhomes Durham County To whom it may concern: NC Dept of Environmental Quality UCT 2 5 2018 Raleigh Regional Office The Lumley Road Townhome project involves the construction of a new subdivision consisting of 93 townhomes and the associated roads and infrastructure. The site is located on the south side of Lumley Road, east of the intersection of Lumley Road and Page Road just west of the Durham -Wake County line in Durham County. The proposed improvements include the construction of approximately 1,906 ft of new 8" gravity sewer main and the services for each lot that will discharge into an existing public gravity main on the west side of the site. Please find attached three full-size copies and one half-size set of plans for the project that show the proposed sewer extension. Also attached are a project narrative, the completed application form (FTA 04- 16), the completed Flow Tracking Acceptance Form (FTSE 04-16), maps of the site, and a $480 check. Please begin your review of these plans and the associated submittal documents and if you have any questions regarding this matter, please do not hesitate to call me at (919) 682-0368. We look forward to hearing from you. Sincerely, Coulter Jewell Thames, PA A4 447 Preston B. Roy ter, PE Project Engineer PROJECT NARRATIVE Lumley Road Townhomes September 25, 2018 The Lumley Road Townhome project involves the construction of a new residential development consisting of 93 townhomes and the associated public streets and infrastructure. The site is located on the south side of Lumley Road, east of its intersection with Page Rd within the City limits for the City of Durham in Durham County. Based on the 2T rules, the anticipated design sewage flow has been calculated to be 33,480 gallons/day (93 townhomes x 3 bedrooms x 120 gpd/bedroom). There is an existing public gravity main (owned and maintained by Durham County) on the west side of the site. The proposed improvements include the construction of approximately 1,906 ft of new 8" public gravity sewer main and the services for each lot. The proposed main will eventually be part of Durham County's public sewer system. �} � � �� k..� - ��.-C1,--�. _-� .�� ��--x --�_� � � �.+ fir• 1, tit '_ �- � - - -- � ~�� �, ��• .=.��r ' I � �y�.. fm a { ER Xtot Lu 59 .. 400 - `" - -~ EP'¢ Lj .. M LLI k7( f - _ _ 4 d~� �, ti W `0�7 ;�j Of- } +fj ` \ °¥ % � 5 r @m Cl � 2 / w a LL ; & ©^®� ƒ { ;2 \ \ƒ \ /« . %CU - + CL bu / Fig m )° E 2 a m 2 2 � J § §ai � _ } & h �V� k § . n 6 § a_m PH ®"d £ 'D ixU % [§ . J !\am LIJ2 L \ cd m o 0 m, 7o LM k � - m� u % U w a i E e r o %# LL « u § > � 2 ui \ I _ m e n CL BOU;_q . _\ _ ■ _w / / & ��a� _ O A 5 e State of North Carolina Department of Environmental Quality DW-K Division of Water Resources aiviston of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: Durham County Project Name for which flow is being requested: Lumley Road - Townhomes More than one FTSE may be required for a single project if the owner of the WWTP is not responsible far all pump slations along the route of the proposed wastetivaterflow. 1. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Triangle Wastewater Treatment Plant b. WWTP Facility Permit M NC0026051 All flows are in MGD c. WWTP facility's permitted flow 12 d. Estimated obligated flow not yet tributary to the WWTP 2.34844 rt e. WWTP facility's actual avg. flow 4.244 f. Total flow for this specific request 0.03348 o g. Total actual and obligated flows to the facility 6.62592 c" h. Percent of permitted flow used 55.21 a w II. Complete this section for each pump station you are responsible for along the route of his 5 proposed wastewater flow. A List pump stations located between the project connection point and the WWTP: x (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm FIow** Current Avg. Tributary Flow Plus (Name or Capacity, * (Firm / po, Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** Page Park 1.198 0.479 0.087 0.033 0.120 0.359 StirrupIron 3.540 1.416 1.142 0.337 1.479 -0.063 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < p. Downstream Facility Name (Sewer): Durham County Sewer Downstream Permit Number: WQCS00038 Page 1 of 6 FTRF ft4-16 III. Certification Statement: I Stephanie Brixey certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. Signing Official Signature Dill I I" Date Page 2 of 6 FTC F nd_ 1 F PLANNING ASSESSMENT ADDENDUM (PAA) Submit a planning assessment addendum for each pump station listed in Section II where Available Capacity is < 0. Pump Station (Name or Number): Given that: a. The proportion and amount of Obligated, Not Yet Tributary Daily Flow (C) accounts for 23.7 % and 0.337 MGD of the Available Capacity (E) in Pump Station Stirrup_ Iron Creek ; and that b. The rate of activation of this obligated, not yet tributary capacity is currently approximately 0.10 MGD per year; and that c. A funded Capital Project that will provide the required planned capacity, namely IFB 18-029: Stirrup Iron Creek Lift Station is in design or under construction with Capacity Improvements ag0039913) planned completion in May 2019 ; and/or d. The following applies: See email chain between Kyle Manning Durham Count and Jason Robinson E concerning two pume failures at the station. The current firm capacity is based upon the 160 hp bypass pumj2 being in operation with the 70 hp pump. Once the capital project is completed, the firm capacity will be 6.5 MGD. Therefore: Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted, without a significant likelihood of over -allocating capacity in the system infrastructure. I understand that this does not relieve the collection system owner from complying with G.S. 143- 215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste disposal system. C�7 Signing Of vial Signature d fla ee Page 3 of 6 FTC F Ad- i r%