Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0040504_Application (FTSE)_20181024
State of North Carolina DWR Department of Environmental Quality Division of Water Resources 15A NCAC 02T.0300 �- FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION This application is for sewer extensions involving gravity sewers, pump stations and force mains, or any combination that has been certified by a professional engineer and the applicant that the project meets the requirements of I5A NCAA: Q21 and the Division's Minimum Design Criteria and that plans, specifications and supporting documents have been prepared in accordance with, NCAC 02T, 15A NCAC 02T.0300, Division policies and zood en ineerin ractices. While no upfront engineering design documents are required for submittal, in accordance with 15A NCAC 02T .0305(b), design documents must be prepared prior to submittal of a fast track permit application to the Division. This would include plans, design calculations, and project specifications referenced in 15A NCAC 02T .0305 and the applicable minimum design criteria. These documents shall be available upon request by the Division. Projects that are deemed permitted (do not require a permit from the Division) are explained in 15A NCAC 02T.0303. le Projects rjli retrack process (must submitted 11technical )Poesthat quire an enreview via vironmental mental asessmenin accordancewih 15ANCAC1C 0100fE'�v�ronmenta1Qua1it� Projects that do not meet any part of the minimum design criteria (MDC) document; -tyCDepto D Projects that involve a variance from the requirements of 15A NCAC 2T; UC� t; 2018 Pressure sewer systems utilizing septic tank-efflucnt pumps (STEPS) or simplex grinder pumps; D STEP or simplex grinder pumps connecting to pressurized systems (e.g. force mains); geg �� O1C� D Vacuum sewer systems. 10 'alew, General - When submitting an application, please use the following instructions as a checklist in order to ensure aII required items are submitted. Adherence to these instructions and checking the provided boxes will help produce a quicker review time and reduce the amount of requested additional information. Failure to submit all required items will necessitate additional processing and review time, and may result in return of the application. Unless otherwise noted, the Applicant shall submit one original and one copy of the application and supporting documentation. A. One Original and One Copy of Application and Supporting Documents ED Required unless otherwise noted B. Cover Letter (Required for All Application Packages): ® List all items included in the application package, as well as a brief description of the requested permitting action. Be specific as to the system type, number of homes served, flow allocation required, etc. If necessary for clarity, include attachments to the application form. C. Application Fee (All New and Major Modification Application Packages): ® Submit a check or money order in the amount of $480.00 dated within 90 days of application submittal. Z Payable to North Carolina Department of Environmental Quality (NCDEQ) D. Fast Track (Form: FTA 04-16) Application (Required for All Application Packages): ® Submit the completed and appropriately executed application. D If necessary for clarity or due to space restrictions, attachments to the application may be made. ❑ If the Applicant Type in Item I.2 is a corporation or company, provide documentation it is registered for business with the North Carolina Secretary of State. ❑ If the Applicant Type in Item I.2 is a partnership or dfb/a, enclose a copy of the certificate filed with the Register of Deeds in the county of business. ® The Project Name in Item II. I shall be consistent with the project name on the flow acceptance letters, agreements, etc. ® The Professional Engineer's Certification on Page 5 of the application shall be signed, sealed and dated by a North Carolina licensed Professional Engineer. ® The Applicant's Certification on Page 5 of the application shall be signed in accordance with 15A NCAC 02T .0106 b . Per 15A NCAC 02T .0106(c), an alternate person may be designated as the signing official if a delegation Ietter is provided from a person who meets the criteria in 15A NCAC 02T.0 106(b), INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Paget of3 E. Flow Tracking/Acceptance Form (Form: FTSE 04-16) (if Applicable): ® Submit the completed and executed FTSE Form from the owners of the downstream sewers and treatment facility. Multiple forms maybe required where the downstream sewer owner and wastewater treatment facility are different. i- The flow acceptance indicated in form FTSE must not expire prior to permit issuance and must be dated less than one year prior to the application date. Submittal of this application and form FTSE indicates that owner has adequate capacity and will not violate G.S. 143- 215.67(x). - Intergovernmental agreements or other contracts will not be accepted in lieu of project -specific FTSE. F. Site Maps (All Application Packages): ® Submit an 8.5 -inch x 1 I -inch color copy of a USGS Topographic Map of sufficient scale to identify the entire project area and closest surface waters. D Location of the project (gravity sewer, pump stations & force main) Downstream connection points and permit number (if known) for the receiving sewer ® Include a street level map showing general project area. G. Existing Permit (Ali Modification Packages): ❑ Submit the most recently issued existing permit. ❑ Provide a Iist of any items within the permit the Applicant would like the Division to address during the permit modification (i.e., permit description, flow allocation, treatment facility, etc.). H. Power Reliability Plan (Required if portable reliability option utilized for Pump Station): ❑ Per 15A NCAC 02T.0305(hI , submit documentation of power reliability for pumping stations. This alternative is only available for average daily flows less than 15,000 gallons per day It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant and is compatible with the station. The Division will accept a letter signed by the applicant (see 15A NCAC 02T .0f 06(b)) or proposed contractor, stating that "the portable power generation unit or portable, independently -powered pumping units, associated appurtenances and personnel are available for distribution and operation of this pump station." Ir the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the ease of a multiple station power outage. (Required at time of certification) I. Certificate of Public Convenience and Necessity (All Application Packages for Privately -Owned Public Utilities): ❑ Per 15A NCAC 02T .01 15 a I provide the Certificate of Public Convenience and Necessity from the North Carolina Utilities Commission demonstrating the Applicant is authorized to hold the utility franchise for the area to be served by the sewer extension, or ❑ Provide a letter from the North Carolina Utilities Commission's Water and Sewer Division Public Staff stating an application for a franchise has been received and that the service area is contiguous to an existing franchised area or that franchise approval is expected. J. Operational Agreements (Applications from HOA/POA and Developers for lots to be sold): ❑ HomeiProyerty Owners' Associations ❑ Per 15A NCAC 02T .0115(c), submit the properly executed Operational Agreement (FORM -.1-10A). ❑ Per 15A NCAC 02T.01 15(c), submit a copy of the Articles of Incorporation, Declarations and By-laws. ® Developers of lots to be sold ® Per 15A NCAC 02T.01 15(b), submit the properly executed Qfserational Agreement FORM: DEV . For more information, visit the Division's collection systems tivebsite INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 2 of 3 THE COMPLETED APPLICATION PACKAGE INCLDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Re conal Office 2090 US Highway 70 Avery, Buncombe, Burke, Caldwell, Cherokee, Water Quality Section Swannanoa, North Carolina 28778 Clay, Graham, Haywood, Henderson, Jackson, (828) 296-4500 Macon, Madison, McDowell, Mitchell, Palk, (828) 299-7043 Fax Rutherford, Swain, Transylvania, Yancey Fayetteville Re conal Office 225 Green Street Suite 714 Anson, Bladen, Cumberland, Harnett, Hoke, Water Quality Section Fayetteville, North Carolina 28301-5094 Montgomery, Moore, Robeson, Richmond, (910) 433-3300 Sampson, Scotland (910) 486-0707 Fax Mooresville Regional Office 610 E. Center Avenue Alexander, Cabarrus, Catawba, Cleveland, Water Quality Section Mooresville, North Carolina 28115 Gaston, Iredell, Lincoln, Mecklenburg, Rowan, (704) 663-1699 Stanly, Union (704) 663-6040 Fax Raleigh Regional Office 1628 Mail Service Center Chatham, Durham, Edgecombe, Franklin, Water Quality Section Raleigh, North Carolina 27699-1628 Granville, Halifax, Johnston, Lee, Nash, (919) 791-4200 Northampton, Orange, Person, Vance, Wake, (919) 788-7159 Fax Warren, Wilson Washin ton Re conal Office 943 Washington Square Mall Beaufort, Bertie, Camden, Chowan, Craven, Water Quality Section Washington, North Carolina 27889 Currituck, Dare, Gates, Greene, Hertford, Hyde, (252) 946-6481 Jones, Lenoir, Martin, Pamlico, Pasquotank, (252) 975-3716 Fax Perquimans, Pitt, Tyrrell, Washington, Wayne Wilmington Re Tonal Office 127 Cardinal Drive Extension Brunswick, Carteret, Columbus, Duplin, New Water Quality Section Wilmington, North Carolina 28405 Hanover, Onslow, Pender (910) 796-7215 (910) 350-2004 Fax Winston-Salem Regional Office 450 W. Hanes Mill Road Alamance, Alleghany, Ashe, Caswell, Davidson, Water Quality Section Suite 300 Davie, Forsyth, Guilford, Rockingham, Randolph, L Winston-Salem, North Carolina 27105 (336) 776-9800 Stokes, Sury, Watauga, Wilkes, Yadkin i - I INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 3 of State of North Carolina DWR Department of Environmental Quality Division of Water Resources 15A NCAC 02T.0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number_ (to be completed by DWR) All items must be com leted or the application will be returned I. APPLICANT INFORMATION: I. Applicant's name: Durham County (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ® State/County ❑ Municipal ❑ Other 3. Signature authority's name: Stephanie Brixey_ per 15A_NCAC 02T.0106(b Title: Denuty Director / POTW Director 4. Applicant's mailing address: 5926 Fiighway 55 East City: Durham State. NC Zip: 27713- 5. Applicant's contact information- qz Phone number: 919) 560-9034 Email Address: sbrixey(a',dconc.eov II. PROJECT INFORMATION: I . Project name: Davis Park Townhomes 2. Application/Project status: ® Proposed (New Permit) ❑ Fxisting Permit/Project If a modification, provide the existing permit number. WQ00 and issued date: _ If new construction but part of a master plan, provide the existing permit number: WQOD 3. County where project is located: Durham 4. Approximate Coordinates (Decimal Degrees). Latitude: 35.8806 Longitude: -78.8565- 5. Parcel ID (if applicable): (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Bradley Rhinehalt License Number: 21543 Firm: McAdams Mailing address: 2905 Meridian Parkwa City: Durham State: NC Zip: 27713 - Phone number: (919) 36I -5000 Email Address: rhinehalt a.,mcadamsco.com 1V. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: I. Facility Name: Triangle WWTP Permit Number: NCO026051 Owner Name: Durham County V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): I. Permit Number(s): WQ0038873 8" & Unknown -Built 198306") Downstream (Receiving) Sewer Size- 88 16" inch System Wide Collection System Permit Number(s) (if applicable): WQCS00038 Owner Name(s): Durham County FORM: FTA 04-16 Page I of 5 VL GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N'A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV} been attached? [:]Yes ❑No ®N. -'A 3. If the Applicant is a Home?Pro ert Owners' Associalion, has an Operational Agreement (FORM: HOA) been attached? ❑ Yes []No ®NIA 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/scrvice ❑ Hotel and/or Motels ❑ School / preschool ! day care ❑ Medical I dental i veterinary facilities ❑ Swimming Pool ;Clubhouse ❑ Food and drink facilities ❑ Church El Businesses ;offices/ factories El Swimming Pool+Filter Backwash ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater : 100 % Domestic,'Commercial % Commercial _ % Industrial (See 15A NCAC 02T .0 103 20 IIs there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Has a flow reduction been approved under I5A NCAC 02T &I 14(f)? ❑ Yes ® No If vesprovide a copy of flow reduction approval letter 7. Summarize wastewater generated by project= Establishment Type (see 02T.ol 14(f)) Daily Design Flow a.n No. of Units Flow Townhomes (3 Bedroom Units) 360 gal/unit 0 gal/sf 140 0 50,400 GPD GPD 0 gal/day 0 gal/day gall 0 0 GPD GPD GPD gal/ GPD Total 50,400 GPD a See 15A NCAC 02T.0114(b),i&h;)f 1 and Lei?} for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4), b Per 15A NCAC 02T.01 14(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 50.400 GAD (per I5A NCAC 02T.01 14) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why_ ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain) - I' ORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T.0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 3209 PVC 8 219 DIP ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria D Section III contains information related to minimum slopes for gravity sewer(s) :- Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC Pum Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: __ CLongitude: 3. Design Flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .03050M ): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(13), :- Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS -- (02B.0200 & 15A NCAC 02T.0305(f)): 1. Does the project comply with all separations found in 15A NCAC 02T.0305(f) & 15A NCAC 02T.0305(f) contains minimum cenaraIinn c that chglI hr- nrmArlRd r„r e..- r of�,.,�. ® Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet **Any private or public water supply source, including any wells, WS -1 waters of Class I or Class 11 impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS -1 or WS -V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item IX.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slo a of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade vertical 36 inches 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. **Stream classifications can be identified using the Division's NC Surface Water Classifications webl2age ". 1f noncompliance with 02T.0305(f) or (p,), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes [-]No See the Division's draft separation requirements for situations where separation cannot be meet No variance is required if the alternative design criteria specified is utilized in design and construction As built documents should reference the location of areas effected 3. Does the project comply with all setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No This would include Trout Buffered Streams per 15A NCAC 213.0202 4. Does the project comply with an individual 404 Permit or any 401 Certifications? ® Yes ❑ No Wetland -related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0 105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T,0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high-priority?" Per 15A NCAC 02T.0402, "high-priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design- Criteria for the Permittini of Pump Stations and Force Mains latest version and the Gravity Sewer Minimum Design Criteria latest version as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and su,goortina documents. 2. Professional Engineer's Certification: RJA ! attest that this application for (Profession Engineer's name from Application Item IIL1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that f have reviewed this material and have judged it to be consistent with the proposed design. NOTE - In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S 10,000, as well as civil penalties up to $25,000 per violation. `,�ktt+ 1 t t r ``.K.. !� ........ .�.O.0 A.R } .} ...... North Carolina Professional Engineer's seal, signature, and date: �� 09 O ' SEAL y �9'•. FTG r N rc� .'Q" A. R 3. Applicant's Certification per 15A NCAC 02T .0106(b): vrLOOf attest that this application for (Signature Autho i)y's name & title om Application Item I.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. 1 also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE - In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S 10,000 as well as civil penalties up to $25,000 per violation. Signature:_ Date: ���_Va FORM: FTA 04-16 Pagc 5 of State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: Durham Count Project Name for which flow is being requested: Davis Park Townhomes More than one FTSE ntap be required for a single project if the owner of the WffT'P is not responsible for all pump stations along the route of the proposed wasteteater flou+. 1. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Triangle Wastewater Treatment Plant b. WWTP Facility Permit #: NCO026051 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flows are it: MGD 12 2.418 4.244 0.050400 6.712 55.94 II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations Iocated between the project connection point and the WWTP: (E) -(A -D) Available Capacity*** * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not Iess than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Durham County Sewer Downstream Permit Number: WQCS00038 Page 1 of 6 I= T',; 04-16 (A) (B) (C) (D)=(B+C) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity, (Firm ! p0, Daily Flow, Daily Flow, Obligated Number) MGD MGD MGD MGD Flow (E) -(A -D) Available Capacity*** * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not Iess than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Durham County Sewer Downstream Permit Number: WQCS00038 Page 1 of 6 I= T',; 04-16 III. Certification Statement: I Stephanie Brixey certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. Signing Official Signature N Dale Page 2 of 6 FTSE 04-16 M+ixd1 k 11_I■J KI:hl :i:a r. � f r T �- � i• R s� :4`r�Fr •7 SO DAVIS FiA-RK TOWNHOMES SITE IL ZP' Pm x.44 • S / I 1 4 � it at 1 • ,� 3�T97S �s ] q - - �`�'1:";Y �;•,5' QM)a c I = `, • * ±.:!;#,y �•i �` ��nG'�o � - "9 1irl�i e elr {��1,�3}.��.,�1����r fl^r.�a� / ' L�.3 CJI MCADAMS October 24, 2018 NCDEQ— DWR Raleigh Regional Office 1628 Mail Service Center Raleigh, North Carolina 27699-1628 RE: Davis Park Townhomes _ Pr[ - Durham, North Carolina PLT -17000 COVER LETTER > PLT -17000 NC Mpt (if Enviroumental Quality OCT z 4 2018 Raleigh Regional Office The accompanied Fast -Track Application (FTA 04-16) includes 3,209 lineal feet of 8" PVC and 219 lineal feet of 8" DIP gravity sanitary sewer for the proposed Davis Park Townhomes development located at the intersection of Davis Drive and Hopson Road in Durham, NC. The sewer system will be a public system owned and operated by Durham County. The private collection system is being permitted separately. A letter of transmittal has been provided with detailed description of items included in submittal. - Sincerely, MCADAMS J byj- (zk Bradley Rhinehalt, PE Senior Project Manager, Residential CY/ca creating experiences through experience 2905 Meridian Parkway, Durham, NC 27713 / 919. 361. 5000 M' MCADAM.S Date: October 24, 2018 To. NCDEQ Raleigh Regional LETTER OF TRANSMITTAL WAND DELIVER Re: Davis Park NCDEQ Submittal 3800 Barrett Drive Raleigh, North Carolina 27609 Job #: PLT -17000 I am sending you the following items: ❑ Drawings ❑ Letter ❑ Statement of Qualifications ❑ Specifications © Submittal ❑ Other ❑ Plans ❑ Prints QUANTITY UNIT DESCRIPTION 2 Copy + Original Developers Operational Agreement 2 Copy + Original Public Sewer FTA 2 Copy + Original Private Sewer FTA 1 Check $480.00 Fee (Private Sewer) 1 Check $480.00 Fee (Public Sewer) 2 Copy Site Maps WT �� o 2 CopyCover Letters Transmitted as checked below: © For approval ❑ For your use ❑ As requested Remarks: ❑ For review + comment ❑ Other ❑ Other Copy to: Signature: �d Rhinehalt, PE / ca Senior Project Manager, Residential creat ng experiences through exper'ence 2905 Mer.dlan Parkway, Durham, NC 27713 / 919 361. 5000