HomeMy WebLinkAboutNC0033227_NOD-2018-PC-0327_20181128DocuSign Envelope ID: D5FD430A-CE20-4570-A397-E3FCDAB74CD6 ROY- COOPER Catiarnar fICI EL _ RE _A Seoralar-a LDS DA CT_,-LPEPPER Intsrrm Diraclor Jeff Gordon, Manager Plant TE Connectivity Corporation 1396 Charlotte Hwy Fairview, NC 28730 NORTH CAROLINA EizvbTamenral Quafrty November 28, 2018 SUBJECT: NOTICE OF DEFICIENCY Tracking Number: NOD-2018-PC-0327 Permit No. NCO033227 TE Connectivity WWTP Buncombe County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the TE Connectivity WWTP on November 7, 2018. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0033227. A summary of the findings and comments noted during the inspection are provided in the enclosed copy of the inspection report. The Compliance Evaluation inspection was conducted by Division of Water Resources staff from the Asheville Regional Office. The following deficiencies were noted during the inspection: Inspection Area Description of Deficiency Operations & Maintenance Influent overflowed/splashed over plant. Plant is high in solids. Secondary Clarifier The blankets in the clarifier were too high at 7'and 8' of 10' water depth. Solids need to be removed. Plant needs to be able to waste solids. North Carolina Department of Environmental Quality I Division of Water Resources 2090 U.S. 70 Highway, Swannanoa, NC 28778 828-296-4500 DocuSign Envelope ID: D5FD430A-CE20-4570-A397-E3FCDAB74CD6 Inspection Area Description of Deficiency Bar Screens The bar screen had excessive debris allowing influent to spill out of plant onto adjacent ground. Effluent Pipe The streambank at the domestic wastewater effluent pipe (#I) has eroded from recent storms and compromised the effluent pipe and its structure. In addition, the issues below must also be addressed: Compliance Issues: Unknown Plumbing: The WWTP appears to possibly have plumbing for wasting solids (WAS). There is also an unknown pipe in the chlorine contact chamber. This possible WAS plumbing and the unknown pipe in the chlorine contact chamber need to be assessed and verified. Remedial actions should have already been taken to correct this problem and prevent further occurrences in the future. Please submit a written response to this Notice of Deficiency. Your response is to be received by the regional office within 30 business days following receipt of this Notice. If you should have any questions, please do not hesitate to contact Linda Wiggs with the Water Quality Regional Operations Section in the Asheville Regional Office at 828-296-4500. Sincerely, DocuSigned by: 7E617A38285848C... G. Landon Davidson, P.G., Regional Supervisor Water Quality Regional Operations Section Asheville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS — Inspection Report Ec: Asheville Regional Office Laserfiche Doug Dodd (email) G:\WR\WQ\Buncombe\Wastewater\Industrial\Tyco Electronics Corp 33227\Inspections\11-7-2018 Inspect\20181129_NC0033227_NOD2018PC0327.rtf o�wwM w cwra....,w a1wn� North Carolina Department of Environmental Quality I Division of Water Resources 2090 U.S. 70 Highway, Swannanoa, NC 28778 828-296-4500 DocuSign Envelope ID: OEACAC9D-C370-417B-BD9C-4D37A2B97773 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 15 I 3 I NCO033227 111 12 I 18/11/07 I17 18 I S J 19 L G] 201 I 211111 I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I f6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 671 70 I I 71 I I 72 I r I 73 I I 174 751 I I I I I I I80 u ty I I i Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES oermit Number) 03:30PM 18/11/07 18/04/01 TE Connectivity WWTP 1396 Charlotte Hwy Exit Time/Date Permit Expiration Date Fairview NC 28730 05:OOPM 18/11/07 22/12/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Glen L Foster,PO Box 3608 Ms140-42 Harrisburg PA 171053608//717-561-6419/ Yes Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Operations & Maintenance 0 Self -Monitoring Program 0 Sludge Handling Disposal 0 Facility Site Review Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Linda S Wiggs Ds ARO WQ//828-296-4500 Ext.4653/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# DocuSign Envelope ID: OEACAC9D-C370-417B-BD9C-4D37A2B97773 NPDES yr/mo/day Inspection Type (Cont.) NC0033227 I11 121 18/11/07 117 18 ICI Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The Inspector, Linda Wiggs, met with Jason Rummel (ORC) and Doug Dodd (EHS Mgr) onsite. BAR SCREEN: The bar screen had excessive debris. The bar screen is at the water level of the aeration tank and the return solids (RAS) are deliver next to the bar screen. All these issues appear to contribute to the influent spilling/splashing out of plant onto the adjacent ground. An email was received by the Inspector on 11/8/2018 with photos verifying a temporary splash guard was installed to keep wastewater from spilling/splashing over. SOLIDS: The plant was high in solids. Settleability at 30 minutes was 850 ml. The blankets in the clarifier were 7'and 8' of 10' water depth. Solids need to be removed promptly. The log book indicated solids had been pumped in March and July. This WWTP does not have a digester, there is no tank to waste sludge/solids (WAS). However, the WWTP appears to have plumbing for WAS. This plumbing needs to be assessed and its use verified. Tankage (digester) where solids can be sent for removal is a crucial component of a WWTP. The addition of a digester needs to be given serious consideration. CHLORINE CONTACT CHAMBER: There is a large buried tank used as a chlorine contact basin; this basin has an unknown pipe in it. The unknown pipe's origin and destination need to be verified. The original Plans of this WWTP and any ancillary components should be researched. EFFLUENT PIPE: The streambank at the domestic wastewater effluent pipe (001) has eroded from recent storms and compromised the effluent pipe and its structure. This is a safety issue and has compromised the effluent sampling location. Furthermore, the next high flow storm event could break the effluent pipe and dislodge the structure. Page# DocuSign Envelope ID: OEACAC9D-C370-417B-BD9C-4D37A2B97773 Permit: NCO033227 Owner - Facility: TE Connectivity WWTP Inspection Date: 11/07/2018 Inspection Type: Compliance Evaluation Operations & Maintenance Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Influent overflowed/splashed over plant onto ground. Plant high in solids. Bar Screens Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris? Is the screen free of excessive debris? Is disposal of screening in compliance? Is the unit in good condition? Yes No NA NE ❑ ■ ❑ ❑ ■ ❑ ❑ ❑ Yes No NA NE ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Comment: The bar screen had excessive debris allowing influent to spill out of the plant onto the adjacent ground. Aeration Basins Mode of operation Type of aeration system Is the basin free of dead spots? Are surface aerators and mixers operational? Are the diffusers operational? Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin's surface? Is the DO level acceptable? Is the DO level acceptable?(1.0 to 3.0 mg/1) Comment: Plant has too many solids. Settleability at 850 ml after 30 minutes. ORC stated air on/off 30/30 during day and 30/45 during night. Secondary Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Yes No NA NE Ext. Air Diffused ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ Yes No NA NE ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ Page# 3 DocuSign Envelope ID: OEACAC9D-C370-417B-BD9C-4D37A2B97773 Permit: NCO033227 Owner - Facility: TE Connectivity WWTP Inspection Date: 11/07/2018 Inspection Type: Compliance Evaluation Secondary Clarifier Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately'/ of the sidewall depth) Comment: RAS is deliver next to the bar screen addina to turbulence issues Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ■ ❑ ❑ The blankets in the clarifier were too high at Tand 8' of 10' water depth. Solids need to be removed. The log book indicated solids had been pumped in March and July. WWTP needs to be able to WAS. Disinfection -Tablet Yes No NA NE Are tablet chlorinators operational? 0 ❑ ❑ ❑ Are the tablets the proper size and type? 0 ❑ ❑ ❑ Number of tubes in use? 1 Is the level of chlorine residual acceptable? ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? 0 ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? ❑ ❑ ❑ Comment: Chlorine contact chamber is a very large buried basin, similar to a large septic tank. Observation did not indicate solids build up, although it is difficult to see all of the tank. There is an unknown pipe in this tank. De -chlorination Type of system ? Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de -chlorination substance stored away from chlorine containers? Comment: Are the tablets the proper size and type? Are tablet de -chlorinators operational? Number of tubes in use? Comment: Yes No NA NE Tablet ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ 1 Page# 4 DocuSign Envelope ID: OEACAC9D-C370-417B-BD9C-4D37A2B97773 Permit: NCO033227 Owner - Facility: TE Connectivity WWTP Inspection Date: 11/07/2018 Inspection Type: Compliance Evaluation Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? ❑ 0 ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? 0 ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment: The streambank at the domestic wastewater effluent pipe (001) has eroded from recent storms and compromised the effluent pipe and its structure. Page# 5