Loading...
HomeMy WebLinkAboutWQ0040453_Application (FTSE)_20181003k 1( L 1 State of North Carolin a DWR OL-1 Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources15A 04-16 & SUPPORTING DOCUMENTATION Application Number: 15 (to be compleied by DWR) All items must be completed or the a lication will he returned 1. APPLICANT INFORMATION: I. Applicant's name: Town of Smilhfieid (company. municipality. HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation m El General partnership ❑Privately -Owned Public Utility ❑ Federal ❑ Slate/County ® Municipal ❑ Other 3. Si -nature authority's name: Waher Ted Credle per 15A NCAC 02T .0106(b) Title: Director of Public Ulililic+ 4. Applicant's mailing address: 230 Hospital Road City: Smithfield State: NC Zip: 27577- 5. Applicant's contact information: Phone number: (21 ) 934-21 16 Email Address: ted.credlrC)smithfrcld-nc.com II. PROJECT INFORMATION: I. Project name: U-3334B Booker DaiEy Road Sewer Relocation 2. Application/Project status: ® Proposed (New Permit) ❑ Fxisting Permit/Project If a modification. provide the existing permit number. WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00_ 3. County where project is located: Johnston 4. Approximate Coordinates (Decimal Degrees): Latilude: 35.523635 Longitude:-78.307618- 5. Parcel ID (if applicable): NCDOT R/W (or Parcel ID to closest downstream sewer) 1II. CONSULTANT INFORMATION: I. Professional Engineer: James Gregg License Number: 037878 Firm: The Wooten Company Mailing address: 120 N. Boylan Avenue City: Raleigh Slate: NC Lip: 27603-_ Phone number: (919) 828-0531 Email Address: 'ereg2@thewootencom anv.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Johnston Co. Regional WWTP Permit Number: NCO030716 Owner Name: Johnston County V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ_ Downstream (Receiving) Sewer Size: 8 inch System Wide Collection Svslern Permit Number(s) if a licablc : WQCS00270 Owner Name(s): Town of Smithfield FORM: FTA 04-16 Page I of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Ycs [:]No [ON "A 2. If the Applicant is a Developer of lots to be sold, has a PgySl ►ees i per onal Aerr�tent tFgRlWt: DEVI been attached? ❑ Yes ❑No ®N A 3. If the Applicant is a Homes PronPronerty Owners' Association jla!, ari Opotion I Agreement IIF: HOA been attached? ❑ Yes ❑No ®NIA 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and;:or Motels ❑ School preschool t day care ❑ Medical "dental! veterinary facilities ❑ Swimming Pool (Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool.'Filter Backwash ® Businesses : offices I factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 1001!o Domestia'Commercial % Commercial Industrial Q ice ISA NCAC 02T .0103 } �Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Has a flow reduction been approved under I SAJNjt AC 02'i .01 14(1)? ❑ Yes ❑ No If ves, provide a copy of now reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (sec 02T.0114tf11 Daily Design Flow''b INo. of Units Flow gal/ GPD gap GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 0 GPD a See 15A NCAC 02T .01 14(hl,_(d), f c)i 1) aIld (e)(? ) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A 4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table I5A NCAU 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8, Wastewater generated by project. 0 GPD (per 15A XCAC 02T .0 114) 1W Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why_ ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ® Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VI1. GRAVITY SEWER DESIGN CRITERIA or Applicable) - 02T.0305 & MDC(Gravity Sewers I. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 475 DIP Section Il & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria %- Section III contains information related to minimum slopes for gravity sewer(s) Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA or Applicable)— 02T .0305 & MDC f Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT L Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: -_; 3. Design flow of the pump station: __ millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s). _ gallons per minute at — feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station). Size (inches) Length (feet) Material 6. Power reliability in accordance with 5, A NC,�C 02T ,p305(hg [): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(I )(S)_ % Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): % It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. % If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of multiple station power outage. FORM: FTA 04-16 Page 3 of Ia. SETBACKS & SEPARATIONS — (02B .0200 & 1SA NCAC 02T .0305(f)): 1. Does the project comply with all separations found in I5A NCAC 02T .0305(I & (,-,I Yes [-]No 15A NCAC 02T.0305 g contains alternatives where separations in 02T.03050) cannot be achieved, "Stream classifications can be identified using the Division's NC Surface Water Classifications weh age If noncompliance with 02T.0305 or I g) see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ®Yes [:]No ❑ NIA > Seethe Division's draft separation requirements for situations where separation cannot be meet i No variance is required if the alternative design criteria specified is utilized in design and construction As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per I5A NCAC 02B .0200! ® Yes ❑ No ❑ NIA i This would include Trout Buffered Streams per 15A NCAC 213.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? ;;� Information can be obtained from the Oil l K Huffer Permiuin" Branch 5. Does project comply with [SA NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T,0105(c)(6 , directly related environmental permits or certification applications arc being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority'!" Per 15A NCAC 02'r.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ N/A If yes, include an attachment with details for each line, including type (aerial line, size, material, and location)_ High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Vide Collection permit. FORM: FfA 04-16 Pace 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A N AC 02T, [lie Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version). and the Qravitv Sewer Minimum Desi n Criteria late i version as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval or the reguest is re uired prinr to submittal or the Fast Track A lication and supportine documents. 2. Professional Engineer's Certification- 1, 3a-w%e5 Oreqoj _attest that this application for (Professib Engineer's name from Application Item IILI,) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with The applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fasl-Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to S25,000 per violation. North Carolina Professional Engineer's seal, signature, and date:� C AR 0 -1,� _ SEAL ' �+'cr>sE�� 3. Applicant's Certification per 15A NCAC 02T .0106(b): //I I I I L��� 1, Y�-AurEv, r , L R Ej>L5 attest that this application for (Signature Authority's name & title from Application Item 1.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 14-215.6B any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature IJG (.,, ` L Date. - FORM: PTA 04.16 Page 5 of PROJECT NARRATIVE U-3334B SANITARY SEWER RELOCATION TOWN OF SMITHFIELD JOHNSTON COUNTY, NORTH CAROLINA 1.0 PROJECT DESCRIPTION This project proposes the relocation ol'approximately 475 LF of 8-inch gravity sewer and to serve the Town of Smithfield. This line is being; relocated due to road improvement work as part of NCDOT project U-3334B, Booker Dairy Road Extension. The existing sewer is an 8-inch main and is located within the current right-of-way of Ava Gardner Avenue. The proposed 8-inch line will be relocated to a newly extended portion of the right-of-way. Installation of this line currently will not produce any new sewer (lows. lip w ° C, aCD CL U � iI1 o Ca V ° cc* E pw a * vp r. * 4..) CD L lit x t V* -a �. o � L - °ll Co LM - Co a� Co (n 32 tt N N A Ty THE WOOTEN COMPANY 120 North Boylan Ave Raleigh, NC 27603 919.828.0531 tax 919.834,3589 VC Dept Of Envirnniltcn1s11 Quality Raleigh JtCgiottal Office October 2, 2018 Review Engineer N.C. Department of Environmental Quality Division of Water Resources Water Quality Regional Operations Section 1628 Mail Service Center Raleigh, North Carolina 27699-1628 Re: Sanitary Sewer Fast Track Permit U-3334B Booker Dairy Road Extension Sin ithfield.'Johnston County, North Carolina TWC No.2698-BV Dear Review Engineer: On behalf of the Town of Smithfield and NCDOT, we are forwarding to you two (2) copies of the following documents for your review and approval for the above referenced project: • Fast -Track Application (FTA 04-16) • Project Narrative • Design Drawings • Aerial Map • USGS Map I trust the above information is sufficient for your review; however, if you should have any questions or need additional information, please do not hesitate to contact us. Sincerely, THE WOOTEN COMPANY License No. F-0115 James Gregg, P.E. Enclosures: As stated.