HomeMy WebLinkAbout20061224 Ver 1_COMPLETE FILE_20060731O?O? W AT QG
co 7
Mr. J. Ronnie Whetstine
P.O. Box 968
Shelby, NC 28151
Subject: Lot #32, East Ebbie Dr, Moss Lake
Alan W. Klimek, P.E. Director
Division of Water Quality
August 30, 2006
DWQ# 06-1224
Cleveland County
APPROVAL of 401 Water Quality Certification with Additional Conditions
Dear Mr. Whetstine:
You have our approval, in accordance with the attached conditions and those listed
below, to place fill in or to otherwise impact/stabilize the following as described in your
application dated August 10, 2006:
Amount Approved Units Plan Location or Reference
Shoreline 137 feet
404/CAMA Wetlands acres
Waters 0.01 acres
Buffers - Zone 1 N/a s uare ft.) I
Buffers- Zone 2 N/a (square ft.) I
After reviewing your application, we have determined that N.C. Division of Water Quality (DWQ)
General Water Quality Certification Number 3495 covers the impacts. This Certification
allows you to use Nationwide Permit #13 when issued to you by the US Army Corps of
Engineers (USACE). In addition, you should obtain or otherwise comply with any other required
federal, state or local permits before you proceed with your project, including (but not limited to)
those required by Erosion and Sediment Control, Non-Discharge, Duke Power, and Water
Supply Watershed regulations.
The above noted Certification will expire when the associated USACOE's 404 permit
expires unless otherwise specified in the General Certification. This approval is for the purpose
and design that you described in your application. If you change your project, you must notify
this office and you may be required to submit a new application. If the property is sold, the new
owner must be given a copy of this Certification and approval letter and is thereby responsible
for complying with all conditions.
This approval requires you to follow the conditions listed in the attached certification and
any additional conditions listed below.'
All stormwater shall be directed as diffuse flow at non-erosive velocities through the
protected stream buffers and will not re-concentrate before discharging into the stream as
identified within 15A NCAC 2B.0243(5). ;Vatu Carolina
Michael F. Easley, Governor
William G. Ross Jr., Secretary
North Carolina Department of Environment and Natural Resources
North Carolina Division of Water Quality 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone (704) 663-1699
Customer Service Internet: ncwaterquality.org FAX (704) 663-6040
1-877-623-6748
An Equal Opportunity/Affirmative Action Employer- 50% Recycled/10% Post Consumer Paper
Page 2 of 2
2. Upon completion of all work approved by this 401 Water Quality Certification, and any
subsequent approved modifications, the applicant is required to return the attached
certificate of completion form to the 401 Oversight/Express Review Permitting Unit, North
Carolina Division of Water Quality, 1650 Mail Service Center, Raleigh, NC, 27699-1650.
Violations of any condition herein set forth may result in revocation of this Certification
and may result in criminal and/or civil penalties. If you do not accept any of the conditions of
this Certification (associated with the approved wetland or stream impacts), you may ask for an
adjudicatory hearing. You must act within 60 days of the date that you receive this letter. To
ask for a hearing, send a written petition, which conforms to Chapter 150B of the North Carolina
General Statutes, to the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh,
N.C. 27699-6714. This certification and its conditions are final and binding unless you ask for a
hearing.
Any disputes over determinations regarding this Authorization Certificate (associated
with the approved buffer impacts) shall be referred in writing to the Director for a decision. The
Director's decision is subject to review as provided in Articles 3 and 4 of G.S. 150B.
This letter completes the review of the Division of Water Quality under Section 401 of the
Clean Water Act and the Catawba riparian buffer protection rule as described within 15A NCAC
2B .0243. If you have any questions, please telephone Cyndi Karoly at 919-733-1786 or Alan
Johnson at 704-663-1699.
Sincerely,
n%limek.
for Alan P.E.
E
cc: Ian McMillan, Wetlands Unit
USACE Asheville Regulatory Field Office
Becky Fox, EPA
Central Files
D?
SAP x, 6
yt?? ?° sSa ?Qn?AI-a?cH
Triage Check List
Date: 8/10/06 Project Name: J. Ronnie Whetstine, Lot 32
DWQ#: 06-1224
County: Cleveland
Alan Johnson, Mooresville Regional Office
To:
60-day Processing Time: 8/10/06 -10/08/06
From: Cyndi Karoly Telephone : (919) 733-9721
The file attached is being forwarded to you for your evaluation.
Please call if you need assistance.
? Stream length impacted
? Stream determination
Wetland determination and distance to blue-line surface waters on USFW topo maps
? Minimization/avoidance issues
? Buffer Rules (Meuse, Tar-Pamlico, Catawba, Randleman)
? Pond fill
Mitigation Ratios
? Ditching
? Are the stream and or wetland mitigation sites available and viable?
? Check drawings for accuracy
? Is the application consistent with pre-application meetings?
? Cumulative impact concern
mments: As per our discussion regarding revision of the triage and delegation processes,
se review the attached file. Note that you are the first reviewer, so this file will need to be
wed for administrative as well as technical details. If you elect to place this project on hold,
ask the applicant to provide your requested information to both the Central Office in
h as well as the Asheville Regional Office. As we discussed, this is an experimental, interim
ire as we slowly transition to electronic applications. Please apprise me of any
ations you encounter, whether related to workload, processing times, or lack of a "second
" as the triage process in Central had previously provided. Also, if you think of ways to
his process, especially so that we can plan for the electronic applications, let me know.
WA T?RQ Michael F. Easley, Governor
-O G William G. Ross Jr., Secretary
? North Carolina Department of Environment and Natural Resources
Alan W. Klimek, P.E. Director
Division of Water Quality
August 1, 2006
DWQ Project # 06-1224
Cleveland County
CERTIFIED MAIL: RETURN RECEIPT REQUESTED
J. Ronnie Whetstine
PO Box 968
Shelby, North Carolina 28151
Subject Property: Whetstine: Lot 32 Silo Acres
PCN Application Sets
® REQUEST FOR MORE INFORMATION
RETURN OF APPLICATION PACKAGE
Dear Mr. Whestine:
On July 31, 2006, the Division of Water Quality (DWQ) received your application dated July 27, 2006 for
the above referenced project. The DWQ has determined that your application was incomplete and/or
provided inaccurate information as discussed below. The DWQ will require additional information in
order to process your application to impact protected wetlands and/or streams on the subject property.
Therefore, unless we receive five copies of the additional information requested below, we will have to
move toward denial of your application as required by 15A NCAC 2H.0506 and will place this project on
hold as incomplete until we receive this additional information. Please provide the following information
so that we may continue to review your project.
Additional Information Requested:
? Water Quality Certification, See I. Processing, Item 2.. Please state which Permit
(Nationwide, Regional or General) number you intend to use. Please contact the U.S. Army
Corps of Engineers in the Regional Office to determine which permit you will need to
apply for to perform your proposed activity, and then resubmit your PCN application Water
Quality Certification listing this permit number under I Processing, Item 2., and checking the
boxes for "Section 404 Permit" and "401 Water Quality Certification" under I. Processing,
Item 2 (page 5 of 12).
? DWQ requires the name of an individual shown as "Owner/Applicant" to set up the project.
? The PCN Application failed to contain the Applicant/Agent's Signature and Date. See last
page of application. (Agent's signature is valid only if an authorization letter from applicant is
provided).
? Water Body information not stated. See III Project Information, Item 7.
401 Oversight/Express Review Permitting Unit
1650 Mail Service Center, Raleigh, North Carolina 27699-1650
2321 Crabtree Boulevard, Suite 250, Raleigh, North Carolina 27604
Phone: 919.733-1786 / FAX 919-733-6893 / Internet: httv://h2o.enr.state.nc.us/ncwetlands
An Equal Opportunity/Affirmative Action Employer - 50% Recycled/10% Post Consumer Paper
tvat Carolina
ura!!y
A
l'
? Lack of permitting fee. Please note that beginning January 1, 1999, the N.C. General
Assembly passed legislation requiring payment of a fee for all 401 applications. The fee for
applications is $200 for projects impacting less than an acre of wetland and less than 150
linear feet of streams. For projects impacting one or more acres of wetland or 150 or more
feet of streams, the fee is $475.
? Incorrect permitting fee. Please see above item. Your check # for $ is
herein enclosed.
? A request for a modification of an issued permit requires re-submission of five (5) application
sets and appropriate fee. We have herein returned your modification request.
? Application was missing pages or sections of information. See Other section below.
® DWQ requires five (5) complete PCN application sets to initiate the review process. Please
supply four (4) more application copies. We acknowledge receipt of the copies of the
shoreline improvement plan and do not need any additional sets of that item.
? OTHER:
Please contact the DWQ within three weeks of the date of this letter to verify that you have received this
letter and that you remain interested in continuing to pursue permitting of your project and will be
providing the DWQ the requested information at a later date. Please contact this office in writing and
Alan Johnson of the DWQ Mooresville Regional Office. If we do not hear from you within three weeks,
we will assume that you no longer want to pursue this project and we will consider the project as
withdrawn.
This letter only addresses the application review and does not authorize any impacts to wetlands, waters
or protected buffers. Please be aware that any impacts requested within your application are not
authorized (at this time) by the DWQ. Please call Mr. Ian McMillan or Ms. Cyndi Karoly at 919-733-
1786 if you have any questions regarding or would like to set up a meeting to discuss this matter.
Sincerely,
` "
Cyndi Karoly, Supervisor
401 Oversight/Express Review Permitting Unit
CBKl1jd
cc: Alan Johnson, DWQ Mooresville Regional Office
File Copy
Central Files
Filename: 061224JRW hetstine(Clevela nd)_ApplSets
JL1_-27-2006 08:10 FROM:FRED B BLACKLEY ASLA 704-484-1731 TO:7047393211 P.4
The following is an abbreviated application form for those applying for a 401 Water
Quality Certification to impact FERC (Federal Energy Regulatory Commission)
regulated lake shore or bottom under the U.S. Army Corps of Engineers Permit
GP30. This Application cannot be used for wetland or stream impacts. Please
provide seven (7) copies of this application and supporting information as well as a
non-refundable application fee to the Division of Water Quality of $200.00 for
impacts of to lake bottom of less than 1 acre and $475.00 for impacts to lake bottom
of greater or equal to 1 acre.
Applications should be sent to: 2 0 0 6 1 2 2 4
Division of Water Quality Wetlands Unit _
1650 Mail Service Center
Raleigh, NC 27699-1650
( E l-` . L D
1. Applicant Information
AUG 1 0 Zoos
1. Owner/Applicant Information NR - WATER QUALITY
Name: T. !x/41-/S??i--?c DE sANrosr
MM44
Mailing Address:/A.9 6. 9' .5 4 -_/4,Zi N
Telephone Number: -7 77- 7 Sq Fax Number: 7o y- 73 9 - s 2. //
E-mail Address:
2. Agent Information (A signed and dated copy of the Agent Authorization letter
must be attached if the Agent has signatory authority for the owner/applicant.)
Name:
Company Affiliation:
Mailing Address:
Telephone Number. Fax Number:
E-mail Address:
H. Project Information
Attach a vicinity map clearly showing the location of the property with respect to
local landmarks such as towns, rivers, and roads. Also provide a detailed site
plan showing property boundaries and development plans in relation to
surrounding properties. You may use the diagram below to make a hand sketch of
JUL 3 e 2006
I V.14t? - VVP cR QUALITY
E' '> l iiJ):DS til'No 5TORP/14JINTFR F(1144GN
J+-27-2006 08:10 FROM:FRED B BLACKLEY ASLA 704-484-1731 TO:7047393211 P.5
- ..
your project. Also, see the example below for guidance. Both the vicinity map and
site plan must include a scale and north arrow. The footprints of all buildings,
impervious surfaces, or other facilitics must be included.
Location
County: G l e u ?/? Nearest Town:
Subdivision name or site address (include phase/lot number): z=op?if A? G l?rc Dr?-
Directions to site please include road numbers, landmarks, etc. (This is not
necessary if an adequate vicinity map is included): 4o 7- 3 Z - s I L-u ?4c-r?S
2. Describe the existing land use or condition of the site at the time of this
application: s : fA !`A-.K• ? iii e_s.Yf? ".c ? a .,•? s y cl-?0 y13rG? La7F'
Imo/ ,.i t Td T3 s lea ?-?- s f r.. a d
'0') C'& . Cog c W s ?r?v?bvs r?o?
3. Property size (acres): 9 y 7
4. Nearest body of water (stream/river/sound/ocean/lake): c-
5. Describe the purpose of the pro?Posed work: eA-C) i-e- cf- .51s0 re- "V C_
i- C d d s er 7? t'v t o
6. List the type of equipment to be used to construct the project: 511-d Z a 4dcr
- r-A-A. -1 v.0 e+ A ";o i3" Ta S 120 1- 17*?
7. Amount of impact (including all excavation, backfill, rip rap, retaining walls,
the _n_or;Qal pool lake level in square feet or acres: 5,
etc.) below va
8. a. Amount of impact (including all clearing, back fill, excavation, rip rap,
retaining walls, etc.) above the normal pool lake level and 50 feet land-ward in
square feet or acres: - .z.a d s . f -F• 1364 jej 4 - t S oG S I! Co A.'_SAr" c ; a.y At • Ar C_
b. Please describe vegetation above the normal pool lake level and 50 feet land-
ward to be impacted (number of trees for instance): 'e /0 5 ?.?-ll
:-.J vr-'_ ; r? Q A _ '0 .6 s I3o *Y- Da r??
t/Agent's Signature Date
signature is valid only if an authorization letter from the applicant is provided.)
JUL-27-2006 08:11 FROM:FRED B BLACKLEY ASLA 704-484-1731 T0:7047393211 P.6
PIL-aw approximatelly sketch the fonowing information on this plan
(Tease provide dimensions for each I(em, such as. 10 ft. x 100 ft);
?1) All proposed vegetation vissA g (provide dimensions)
?2) Location of rip rap or fill to be planed above the Full Pond elevation
?33 Location of rip rap or fill to be placed below the Fu0 Pond elevation
4) The location of any proposed structures such as buildings, reUlning
walls. docks, etc.
All,+S) The Location -of any excavation or dredging. below the Full Pond
elevation.
d) Loaatlon of construction access corridors.
JUL-27-2006 08:10 FROM:FRED B BLACKLEY ASLA 704-484-1731 TO:7047393211
i
The following is an abbreviated application form for those applying for a 401 Water
Quality Certification to impact FERC (Federal Energy Regulatory Commission)
regulated lake shore or bottom under the U.S. Army Corps of Engineers Permit
GP30. This Application cannot be used for wetland or stream impacts. Please
provide seven (7) copies of this application and supporting information as well as a
non-refundable application fee to the Division of Water Quality of $200.00 for
impacts of to lake bottom of less than 1 acre and $475.00 for impacts to lake bottom
of greater or equal to 1 acre. p 1-4 @ C. DPI P D
Applications should be sent to: AU G 1? 290) 6 1 2 2 4
Division of Water Quality Wetlands Unit DENR • WATER QUALITYr.
1650 Mail Service Center WETLANDS AND STORMWATER if" M Raleigh, NC 27699-1650
1. Applicant Information
n? f'' 1r LUuo
D&"N - ,7 Ck uuALiIFY
1. Owner/Applicant Information WMWDS AND RT M BRANCH
Name: ',T. t- 4A,-_
Mailing Address:X0 9 r- .5 h
P.4
Telephone Number: -7a &t- y 77- -? 54 Fax Number:
E-mail Address: W c. Ca e /9-r4 Ll v* /3 /'? . ce) ---?
2. Agent Information (A signed and dated copy of the Agent Authorization letter
must be attached if the Agent has signatory authority for the owner/applicant.)
Name:
Company Affiliation:
Mailing Address:
Telephone Number: Fax Number.
E-mail Address:
II. Project Information
Attach a vicinity map clearly showing the location of the property with respect to
local landmarks such as towns, rivers, and roads. Also provide a detailed site
plan showing property boundaries and development plans in relation to
surrounding properties. You may use the diagram below to make a hand sketch of
E 12 @-'?' 2 0 W1 =C,4
JUL 3 1 2006
UtrvN - VVATER QUALITY
1'L,JdUS 'A'D STORMWAM DR/44CH
IE-JUL-27-2006 08:11 FROM:FRED B BLACKLEY JUL-27-2006 08:10 FROM:FRED B BLACKLEY ASLA 704-484-1731
4 'r
P
your project. Also, see the example below fc-- -
site plan must include a scale and north arrow.
impervious surfaces, or other facilitics must
1. Location
County: G 1 c u ?/?
Subdivision name or site address (inclui
Directions to site please include road
necessary if an adequate vicinity map is
2. Describe the existing land use 'or condition
application:
ae r s T? _1
,pv IC'& , td v ? w.
3. Property size (acres): 9 y 7 4-1-'
4. Nearest body of water (stream/river/soul
5. Describe the purpose of the proposed work:
plea" approximately sktkt
(please provides Smertsions i
? ) JW proposOd "JOWiofl SCI
?j) Location of rip FSP or fill t
?93 Location of rip rap or fill t
?/W) Tire location of any props
walls., -dochs, etc.
,t11AS) The location of any excam
elevation.
? 6) Location of construction i
cG ?"
i3 7
6. List the type of equipment to be used to construc
p. rf- A, ;o i3 rrts -T- 6--s- JJ
7. Amount of impact (including all excavation, b
etc.) be1F_ o? a nor al pool lake level in square
g, a. Amount of impact (including all clearing,
retaining walls, etc.) above the normal pool lak
square feet or acres: 4- ? d 3 j
b. Please describe vegetation above the normal
ward to be impacted (number of ttrees for instar
j,?J N?Gt N rry Q r ptapo s
Ap ant/Agent's Signature
( gent's signature is valid only if an authorization letter
JUL-27-2006 08:11 FROM:FRED B BLACKLEY ASLA 704-464-1731 TO:7047393211
Please ai proximately sketch the following information on this plan
ease provide Sinensions for each ftm, such as 10 ft. X 100 ft),
?1) Alt proposed vegetation cieaA g (provide dimensions)
?2) Location of rip rap or till to be planed above the Full Pond elevation
?9? Location of rip rap or fill to be placed Wow the Full Pond elevation
4j The location of any proposed sWetures such as buildings, retaining
vralls.Aocks, etc.
A?1,46) The Location of any excavation or dredging beiow•the Full Pond
elevation.
? 41) Location of construef#on access corridors.
P. 6
WW CONTRACTORS, INC.
72706
7/27/06
7/27/06 8873 DIVISION OF WATER QUALITY
ffl)DELU)E BUSINESS FORMS 1+800-328-0304 ? .dokmefomu.com
8873
200.00 200.00
L?-? u
JUL 3 f 2006
WE11? SR ' AN,) Wn, ST,(1A;i;L Ei- ?;aLrrY 200.00
ARgNCH
12 11 10 9 8 7 6 5 g 4 3 2 1
x SEAL SEAL
Qa~nt o~ 9g, I
`I s `I
a `~\e x,09 0 ~o0 2X8 RAIL CAP 5,_C, ~ F 6 ~ ~ ~ x NOTE: ,gyp ,~0
SITE , O. x~,, x * 1015 SQ. FT. OF PIER DECK ~ ~G ~ ~G
M Stump x ~ Sx~ Sound x x 0 * 25 LF OF WATER FRONTAGE NEEDED M ~ ~
50 Waterway S~ DEPTN = 2~t 2X4 RAIL (TYP) ~x Std _ * 341 LF OF FRONTAGE PROVIDED IN 0~ 0 =PTH = 2't I o9. ~ G G
s ~ TOTAL DEVELOPMENT 0~ 0~ o~ s• F F o 0~ 0~
4X6 POST 4X6 POST x I x C~ C~
i~ 10 2X6 DECKING I a~
x z~ s~.
e 0~ o~ ~s. ~ (EXISTING OYSTER BED s ~~x sy,
Surf 2x10 SYP PT s~ <<, City (2)-~' NIGH STRENGTH ` x ` ` x x
GALV, BELTS W/ 3' ~e Mnx x x o.c. ~0 0~' Atlantic OGEE WASHERS (AT S
fx Sro~e Ocean NUT & BOLTHEAD END) L
d12~rT GIRDER ;;7,. I x~ ~o. x 0~ g~
x~, x PROPOSED 20' X 20' I x
~ ~ ~ 2x12 SYP P ~ x 0~ ~ FIXED DECK I ~ x x 9~,
x x NOT TO SCALE ~ <<. 20.0' `~x
xl S±to 9~ ~s~ x x ~
MHW APPR(1X. xxx ~x - - ~ F ~ x 5±00 9~t x 6g.
Fri I `fig. ~ x 9
x ;c w x I ~ x 0~ 9• ~
NQ ~ ~ 8Z F~ x x x K
~ ~ • K I , x
NORMAL LOW WATER APPROX, I - \ I x\
x ~x. PROPOSED 123 LF \ _ I , ~
w NAT AS 8X8 GR 8' RGUND \ PILES DESIG ED NQ ~ V~ OF 5' WIDE PIER << x g~ .I
> 6 EXISTING XISTING OYSTER BED x I x E ~
o - APPROX, GROUND LEVEL ~ ~ S~ ~ ~ Sl. ! 9.
m ,4 0 99. 0 99 0~ ~ ~x
EDGE OF COASTAL x x ~o x AL x °~D I
WETLANDS x NOTE:
35.0' - ~ * SUBTRACT 0.20' FROM ALL MEAN SEA ~
J LEVEL ELEVATION SHOTS TO OBTAIN
WATER DEPTHS AT MEAN LOW WATER.
APPROXIMATE NORMAL * APPROXIMATE DIFFERENCE IN MEAN RMAL HIGH WATER AND MEAN LOW WATER
HIGH WATER MARK DETERMINED BY VEGETAl10N ARK I ~TAl10N IS ONE FOOT.
4 J. ~4 a4 J. ~4 ,4 i4 ~ ~ ~ ~ I ~ ~ - * ALL ELEVATIONS TAKEN DURING MEAN
~9 Ox `9. LOW WATER. ox
~ ~ ~ m ~ ~
~_4• ~g.
0 x ago x
~ ~ ~ ~ ~ m ~ ~ 4
~ ~
~ FlXED PIER DETAIL ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 4~
1 N.LS COASTAL WETLANDS ~
G
~ ~
~9. ~9.
0 x x 0 x x
m ,4 ,4 ,n r 6,90 69, m .n r. + r m r .r m 0
PROPOSED 367 LF
OF 5' WIDE PIER
~ ~ ~ ~ ~ ~ ~ ~
i+~oo
~ ~ ~ ~ ~ ~ ~
F
E ~ ~'N
MFRS j, ~ , u ADDED SAND BAR, OYSTER BED, & ~ _ - ~ F 7/25/06 REVISED APPROX HIGH WATER MARK ALH
MARSH LINE INE DELINEATED i
404 wETLANDS - REVISED PIER PROFILE & ADDED 56 E 7/18/06 NOTE FOR EXISTING BUILDINGS ALH
36.E 51.2' y ~ , ,n m ~sf' - i
A0 ~ ro rn i ~5~!-'' ~ ~ ~ 7 1 O 06 REVISED NORMAL HWM & ADDED ALH
r. m 9'~ 20 ~,a ' EP D / / OYSTER BED BOUNDARY a ' E ~ ~ 98.5' ~
E ~ e~ u~ y4. p' ~ ~ REVISED PER MARINE FISHERIES 4. o' ' ~ ~ r' ~ ~ ~ C 6 26 06 ALH
~ / / COMMENTS u / ~ r 'y ns i ICJ
~ ~ L i THESE 4 BUILDINGS ARE EXISTING DELINEATED I I T A I B 6/02/06 REVISED PER CAMA COMMEN S LH
ON THIS SITE AT THE TIME OF THE ~ 404 WETLANDS I I I
CAMA PERMIT APPLICATION - ~ r ~ II I i A 04 26 06 ISSUE FOR REVIEW ALH / / I I f
.a ~ I; II I I r r \ .nn
i I I ~ ~ \ REV. ~ 1 ~ DA R VISIONS Y \ I ~ I I N0. TE E B
I ~ ~~x ~~x i I ~
ao~oea I ! uWcew U{N PEIX ii I ~ \ I I 1 I
D I ~ III I i~ D I ~ / V I
Ex~ErNG EXIS?N(~ EXIS?NG BUILDIN; Ex~srN~ ~ I Li 1 ?NG BUILDIN; I I
.F,XIS7ING BUILDING BUILDING 208 GmcaNC 2oa soe DING 208 ~ ~ I 1 ~ I 16 I I ~ ~ ~
20~ I I 1 ' .sa ~ I j
~ / ' I
PIN: 4235-62-2139-0000 ~ ~ ' ~ I li ' PIN: 4235-51-9868-0000 ~ ~ , I , 1 ~
OWNER: BATTS PROPERTIES INC. C/0 AUDREY B. VINER ~ ! yr li i .m 1 ~ OWNER; DAVID C. PRINCE ET AL yr I I 1020 CHERRY WOOD CT ¦En ineerin ¦Architecture¦Surve in ¦Technolo
~ 110 W LAKE RIDGE RD ~ X ~ I ~ ~ LELAND, NC 28451 9 9 y 9 5y I I I I Baa 7305, 324 S. Evans St., Greenville, NC 27834 252-758-3746, 252-830-3954 (Fox) i l i I I .u
RAEFORD, NC 28376 r ~ ~ I i I I PROJECT i1TLE
CONDOMINIUM FIRST FLOOR I i I I ~
~ ELEV. 7.80 / C I I ! IL I ~ I
i I i I i
~I I ~i ATT AN NG L RL III I
~I ~ APPROXIMATE PIER ELEV. 5.00' MSL I, FIXED DOCK I § I I , ~ I
I i ~ i .x I ~ .~,.I ..x ~ ,~a
~ ~ ~ II II I ~ I .~I ~ ~ Pender Count Surf Cit NC
I li I; 'i - ~ I I ~ rf ~'QRAWING T1TLE
I I _ I i ~ - - _ I I - - r`' , _ - I
MARSH BEGINNING I ment r e Deve o P o os d Land I~ P
11 ~ I ~ ,5
6 ! I MEAN LOW WATER _ _ ~3 N• I ~ ~ ~ , aS ~ I ~a s - Pier Detai s
~ esr_..._...-y I I ~ ~ rf- ;'.i . ~ ~ ~-^~.na---...-~
- i I - - - ix - -L I - - _ I s.,, w
I ~ ~
~ GROUNDUNE ELEV. 0.68' MSL ~ I I APPROXIMATE " I ' „o ` SCALE DEPARTMENT ~ ` AS NOTED CIVIL
EARLIER DEVELOPMENT _ _ - x - ~ a - ss ss - ~ - s - - vIENT
_ nui~lr~ /ncvcl nn~~• DRAWN BY DATE STARTED SHEET No.
-0+51.5 0+00 +uu V YYIVLI\~UL VLLVI Ln. ALH 04/21/06 2 OF 2
PIER LOCATION PROFILE - - - - - - - - - - 2 Mike Cole ~ CHECKED DRAWING NO.
C1 HORIZONTAL 1 =50 11CAL 1 =5 MLER
A ~ Corporation A 255_A South Kerr Aven.-- APPROVED
Wilmington, NC 28403
50 25 0 25 O 50
1 "=50'-0" (910) 392-9292 PROJECT NO.
20050321
THIS DRAWNC IS THE THIS DRAWING IS THE PROPERTY [F THE EAST GROUP, P.A. ANY USE, REUSE, REPRODUCTION, SPLAY OR SALE OF THIS DRAWING WITHOUT WRITTEN CONSEN OF THE EAST GROUP, P.A. IS STRICTLY PROHIBITED. (O COP IGHT, THE EAST GROUP. P.A. 2006)
11 10 9 8 7 6 5 12 5 4 3 2 1
GENERAL NOTES FRED B. SLAG L K EY, A SLA
- Property shown hereon may be subject LANDSCAPE ARGttITEG T
easements of record or unrecorded easements
704.484.1731
- Underground utilities have not been located
- No features (Buildings, Utilities, etc.) located
except those shown hereon.
504 SOUTf1 DEKALB STREW T
SI~ELBY, NORT~t CAROLINA 28150
W ~T
E R CI
N E
SURVEY BY
- 1/3 GCVE WIDTf1 - T T. SCOTT BANKHEAD MAXIMUM EXTENT OE ANY SiRUGIURE
1203 E. MARION ST., STE.1
~o, SHELBY , N.C. 28150
704.481.1040
o~ _
Q,
S 54°38 22 E - 8.48 ,
RIPRAP ENTIRE 5'rfOREL1NE ~~F SUBJECT LOT
top- 737.0, toe 734.0
, ~ ~ PROPOSE; ~ ~,T I T
„ 5.18 S 17 E 680 ~ ~ DOGIK „ I RUG ~ ~
g 12 ~3 , 82 0 6 8° ~ 1. xl4' SUNDEGK, 4" WALKWAY, ~C~~~22' BOATSLIP 3 6
N 0 0 E ~
i I
+ =730.0 , ~ W
~ ~ ~ ~
EIP
1 ~ ; _ =733.0 ~ ~ ~6
i ~ ~ ~ ~ ~ i . ~ ;~,x ~ ~ ~ ~
~ U~
J~ / ~ti
P I .
/ , ;,f - STERS AS REQUIRED TO T~AUERSE ~~OPE .J / O
~ ~
coN~ ~ RucrioN c ~ - -REMOVE SCRUBBY ADDERS aL N ~ ~I ~TRUGTION CORRIDOR ~ ~ 0 G S ~ORL~,NE
` CFOR RIPRAP INS INS I AL~ATION) ~ ~ G/i 8.
9
0
0~ ~ ~i
~
off,
c~
_ /
Z 9
ELIZABETH AVENUE ~J
a1 aq~
0 6 ~ a~ ~P°~ -o
S F m ~o z
q0 N
~ c
~ ml d; I
~5.
, W 2g
~ 0 VICINITY MAP T NS
5
,~~uuuW~q .~`~°.~N CARD('°'~
~ ^J~,~~• ~NDSCgp•,~y
' a F~r 1
~'W i- ~ ~L
o a 20.00 ~ ~ •N
2 i
~ 2 g ~ ' ~
1~ '''~nnini„~,, 0
O
0
r~.
0
4 .o
cry,
6',
~ ~ 0 1
o ~ /
ai \ m G l ~ EA 5T DEBBIE DRIVE
1 c
ti S~tELBY, N G
~ ~
cv
a~ ~ EXISTING IRON
C ~ \ TI115 DRAWING IS Th1E PROPERTY OF FRED B. BLAGKLEY. ASLA
O IRON SET AND IS NOT TO BE REPRODUCED OR COPIED IN WIIGLE OR
IN PART WITFtnI lT PFRMISSInN IT I~ NnT Tn RF ~ I~,Fn nN ANv
3 0 CONCRETE MONUMENT OTIIEP PROJECT AND IS TO BE RETURNED UPON REQUEST.
O
N Y U ® NAIL
C ? 0 20' 40' 60' i
POWER/UTILITY POLE & LINES OVERHEAD
SCALE: 1-=20'-0" 7 w 0 WELL
a cn 02/27/OG ,.SFtEET 1 OF 1
3
C
U