Loading...
HomeMy WebLinkAboutWQ0040405_Application (FTSE)_20180925State of North Carolina Department of Environmental Quality DWR Division of Water Resources ISA NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION DIvlslon of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: W Q 00 ''a't7 `F q,5(to be completed by DWR) All items must be completed or the application will be returned 1. APPLICANT INFORMATION: 1. Applicant's name: City of Sanford (company, municipality, I-IOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ® Municipal ❑ Other 3. Signature authority's name: Paul Weeks per 15A NCAC 02T .0106(b) Title: City Engineer 4. Applicant's mailing address: PO Box 3729 �. City: Sanford State: NC Zip: 27330- ��/ 5. Applicant's contact information: C Phone number: 919 777-1119 Email Address: paul.weeks@sanfordnc.net �+ II. PROJECT INFORMATION:CZ v 1. Project name: Botany Woods Area Sewer Extension w 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project q.� a. If a modification, provide the existing permit number. WQ00 and issued date: p If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Lee 4. Approximate Coordinates (Decimal Degrees): Latitude: 35,4954' Longitude:-79.2097' 5. Parcel ID (if applicable): 9633-96-8069-00,_9633-96-1045-00, 9633-95-0679-00, 9633-85-5599-00, 9633-75-6455-00, 9633-94-7612-00 (or Parcel fD to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Mike Apke License Number: 027394 Firm: McGill Associates P.A. Mailing address: 5 Regional Circle, Suite A City: Pinehurst State: NC Zip: 28374- Phone number: 910 295-3159 Email Address: mike.apke(�mceilleneineers.cam IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Big Buffalo Wastewater Treatment Plant Permit Number: NCO024147 Owner Name. City of Sanford V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): W -Unknown Downstream (Receiving) Sewer Size: 30 inch System Wide Collection System Permit Number(s) (if applicable: WQCS0000543 Owner Name(s): City of Sanford FORM: FTA 04-16 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's O erational Ag greement FORM: DEV been attached? ❑ Yes ❑No ®NIA 3. If the Applicant is a 1-iome/PCODerty Owners' Association. has an Operational Agreement _(FORM: HOA) been attached? ❑ Yes []No ®NIA 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /CIubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic/Commercial % Commercial _ % Industrial (See 15A NCAC 02T .0103(20)) 4 Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Has a flow reduction been approved under 15A NCAC 02T .0114(f}? ❑ Yes ® No ➢ If vesprovide a copy of flow reduction aporoval letter 7. Summarize wastewater generated by project: Establishment Type (see 021.01140 Daily Design Flow'-s No. of Units Flow 3-Bedroom Dwelling Unit 120 gal/day/bedroom 36 12,960 GPD gall GPD Sall GPD gal/ GPD gall GPD gal/ GPD Total 12,960 GPD a See 15A NCAC 02T .0114 b d e 1 and e 2 for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 12,960 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VIL GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 4,722 PVC 8 582 DIP ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump_Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: _- Longitude: - 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with .15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B). ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(t)): 1. Does the project comply with all separations found in 15A NCAC 02T .0305 & ➢ 15A NCAC 02T.0305 contains minimum separations that shall be rovided for sewers stems: ® Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains horizontal 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet **Any private or public water supply source, including any wells, WS-1 waters of Class I or CIass II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands (see item IX.2) 50 feet *'"Any other stream, lake, impoundment, or ground water Iowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interce for drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ 15A NCAC 02T.0305 contains alternatives where separations in 02T.0305(fl cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications web a e ➢ If noncompliance with 02T.0305(f) or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) [—]Yes ® No ❑ MA ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No ❑ NIA ➢ This would include Trout Buffered Streams per I5A NCAC 213.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ® Yes ❑ No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401_&_Buffer Permitting Branch 5. Does project comply with 15A NCAC 021.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ® Yes ❑ No ❑ NIA ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02L the Minimum Desi n Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria latest version as applicable? ® Yes ❑ No If No, complete and submit the Variance'Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is re uired prior to submittal of the Fast Track Application and suj!porting documents, 2. Professional Engineer's Certification: I, Michael S. A ke PE _ attest that this application for (Professional Engineer's name from Application Item IIIA.) Botany_ Woods Area Sewer Extension (Facility name from Application Item II.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE - In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0I06(b): 1, Paul Weeks, City En( (Signature Authority's name & title from er Item 1.3.) Botany Woods Area Sewer Extension (Facility name from Application Item II.I.) that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE - In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any ap lication package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well vi penalh up to $25,000 per violation. Signature: Date: FORM: PTA 04-16 Page 5 of 5 State of North Carolina Department of Environmental Quality DWR Division of Water Resources Division of water Resources Flow TrackinglAcceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: City of Sanford Project Name for which flow is being requested: Botany Woods Area Sewer Extension More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewaterflow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Big Buffalo Wastewater Treatment Plant b. WWTP Facility Permit #: NCO024147 All flows are in MGD c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used 12.0 1.14936 3.9020 0.01296 5.06432 42.20% H. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity, * (Firm 1 po, Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the Iargest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Downstream Permit Number: Page 1 of 6 r-T9 ri 1" n A 1 r McGiRSEWERBOTANY WOODS AREA ,OSNO,. GusT3° DATE: AUGl15T2°'° DESIGNED 8Y: MSA FIGURE EXTENSION DAD' cADDer. MR, — BOTANY WOODS AREA ASSOCIATESI A T E S GONST.RE1RENf.` PROJECT VICINITY MAP ENG114EERING•PLANNING•FINANCE $0b"uCMaLRMA.wMLWT..KjLtU rKnikll*l.r, MIU=ti,.0 CITY OF SANFORD, NORTH CAROLINA eaargvwee: ECFqu�dwq PLAN �LINDA ANN GOLDSTON PIN 9633-96-8069-00 DONALD R. & BARBARA H SIMPSON PIN 9633— 96 1045 00 .per ' r_ NORMAN & HOLLY POST PIN 9633-95-0679-00 ROBERT LEONARD & DIANA LANDENBERG PIN 9633-85-5599-00 1000 0 sm 1000 2M GRAPHIC SCALE 1 INCH =1000 FEET Ad I CAROL & ANN YARBOROUGH� PIN 9633-75-6455-00 LEE COUNTY PIN 9633-94-7612-00 -►} li� _ , .11, 9 0 �0 {war 4N% %I ' 0111 ' , '7 {— . PROPOSED V. CONNECTION TO EXISTING SEWER „- MANHOLE d .. I EX STING 30" GRAVITY SEWER LINE PROPOSED GRAVITY #, SEWER a A7t�v t � F McGMSEWERNY WOODS AREA CADDSY� Rs��°`° FIGURE DESIGNED 9Y WAcAnner_ Iuw BOTANY WOODSARf=A EXTENSION 6ESIGNREVIEW._ A S S O C f A T E S CONST. REVIEW _ PROJECT LOCATION MAP [ n fiNGIN[3[RFNG•F'4ANKIHG•FfNANCLCITYOFSANFORD,NORTHCAROLINA L fe[N G IN E.R F IP[G -PnrA N IiC,.� G- 1: MII A N C+ 1: BelfnrlWOO�EC Fgun ewp PLAN PRELIMINARY DESIGN so 0 25 50 l w FOR REVIEW PURPOSES ONLY 01 GRAPHIC SCALE I INCH = 50 FEET NOT RELEASED FOR CONSTRUCTION 2Y CP NL SET T'59.�� W N- 35795 92 PINE 18 rol,. (�J Er 1939568,24 EL- 266,81 POPLAR 15" SSMHOQMG8VH TOP CONCRETE U ` O ' 267.96' 0 .+- :r POP 20" Q !N SET IJL1 i HA 15" P)N i 724 56 O ! �RDWOOD 18 `/\ HARDWOOD OAK 5: PI 8 POA 24" �" POPLAR 18: / POPLAR 12' t 1 1 I �'d2., IiN � �;I 'F' v PLAR 26" 1 ,n POP! AR 17" .26.. 111 2>pl � J � DWOOD 24: FNCWIRE" HARDWOOD 24" 1 oa-nn i t ..nn 113-Lnn I z-Lnn M BOTANY WOODS AREA NO 1104019 'ATE SEPIEMBER2CIESHEET PESIGN£OBY MSA @cGRISEWER EXTENSION £sJOB CAOONR�\4EW. BY .I oicvIEW_,_ AERIAL CROSSING ASSOCIATES CONST REVIEW.-. A CITY OF SANFORD, NORTH CAROLINA EN(1INEERINO•PLANNING-FINANCE I�FItrnY.ma1A.S{�,116�,7irm m. melon" I I mu2mlL g�„„� �. I O McGill A S S O C 1 A T E S September 24, 2018 Danny Smith, Supervisor Raleigh Regional Office North Carolina Department of Environmental Quality Division of Water Resources 3800 Barrett Drive Raleigh, NC 27609 Dear Mr. Smith: NC Dept of Environmental Qua] it) Raleigh Regional Office RE: Fast Track Sewer Application Botany Woods Area Sewer Extension City of Sanford, North Carolina Please find enclosed for your review one (1) original and one (I) copy of a Fast Track Sewer System Extension Application package for the above referenced project. Please also find a check in the amount of $480 to cover the application fee. The overall project includes the installation of approximately 5,300 linear feet of 8-inch gravity sewer line with 28 manholes and related appurtenances along the shoulders of Pine Knoll Drive, Botany Woods Drive, Shannon Drive, and Windmill Drive (all owned and maintained by the City of Sanford), and Wilkins Drive (SR-1328), a State maintained road. Also included is the installation of gravity sewer on several private parcels to connect to the City's existing 30-inch interceptor along Big Buffalo creek. Two (2) bulletin drawings have been attached to show the proposed aerial gravity sewer crossing over Big Buffalo Creek. As a result of this crossing, the project will be covered under Nationwide Permit 12 non -notification for 404 and 401. All applicable permit conditions are included in the plans. A portion of the 8" gravity sewer is within 50 feet of an identified wetland area and will be constructed in accordance with the Division's "Draft Alternative Design Criteria for Minimum Separation for Sewer Systems to Wetlands." The affected areas will also be noted on the project record drawings. 5 Regional Circle, Suite A 1,,. 910.295,3159 Pinchurst, North Carolina 28374 1 910.295,3647 mcgiilengincers , „ Mr. Danny Smith September 24, 2018 Page 2 of 2 If you have any questions during your review or require further information regarding this project, please do not hesitate to give me a call at 910-295-3159. Sincerely, McGILL ASSOCIATES, P.A. Michael S. Apke, P.E. Principal Enclosures cc: Paul Weeks, P.E., City Engineer, City of Sanford 18.04019:' DS. FTA.20180924.doc