HomeMy WebLinkAboutWQ0000165_Inspection_20180813�aw+�
NORTH CAROLINA
Environmental Quality
November 05, 2018
Terry K Barbour
Sands Villa Resort HOA Inc DBA Sands Villa Utilities Inc
1400 E Fort Macon Rd
Atlantic Beach, NC 28512
SUBJECT: Compliance Inspection Report
Sands Villa WWTF
Non -discharge Permit No. WQ0000165
Carteret County
Dear Permittee:
ROY COOPER
Governor
MICHAEL S. REGAN
Secretary
LINDA CULPEPPER
Interim Director
The North Carolina Division of Water Resources conducted an inspection of the Sands Villa WWTF on 8/13/2018.
This inspection was conducted to verify that the facility is operating in compliance with the conditions and
limitations specified in Non -discharge Permit No. WQ0000165. The findings and comments noted during this
inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report".
There were no significant issues or findings noted during the inspection and therefore, a response to this
inspection report is not required.
If you should have any questions, please do not hesitate to contact Morella Sanchez -King with the Water Quality
Regional Operations Section in the Wilmington Regional Office at 910-796-7215 or via email at
morella.sanchez-king@ncdenr.gov.
ATTACHMENTS
Cc: Laserfiche
Sincerely, DocuSigned by:
E
tevti((a S� 6"
E3ABA14AC7DC434...
Morella Sanchez -King, Regional Supervisor
Water Quality Regional Operations Section
Wilmington Regional Office
Division of Water Resources, NCDEQ
North Carolina Department of Environmental Quality I Division of Water Resources
127 Cardinal Drive Extension, Wilmington, North Carolina 28405
910-796-7215
Permit: WQ0000165
SOC:
County: Carteret
Region: Wilmington
Compliance Inspection Report
Effective: 05/13/16 Expiration: 04/30/21 owner: Sands Villa Resort HOA Inc DBA Sands Villa
Utilities Inc
Effective: Expiration: Facility: Sands Villa VWVTF
1400 E Fort Macon Rd
Contact Person: Terry K Barbour
Directions to Facility:
System Classifications: WW3•,
Primary ORC: Stanley Earl Buck
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Title:
Inspection Date: 08/13/2018 Entry Time: 10:30AM
Primary Inspector: Morelia Sanchez -King
Secondary Inspector(s):
Reason for Inspection: Complaint
Permit Inspection Type: High Rate Infiltration
Facility Status: Compliant Not Compliant
Question Areas:
Certification: 993396
Atlantic Beach NC 28512
Phone: 252-247-0519
Phone: 252-503-5307
Exit Time: 11:15PM
Phone: 910-796-7218
Inspection Type: Compliance Evaluation
Treatment Flow Measurement -Effluent Treatment Flow Measurement -Influent Miscellaneous Questions
Treatment Flow Measurement -Water Treatment Treatment Barscreen
Use Records
Treatment Filters Record Keeping Treatment Activated Sludge
Treatment Disinfection End Use -Infiltration Treatment Flow Measurement
(See attachment summary)
DocuSigned by:
dot evt ((a S� 6"
E3ABA14AC7DC434...
11/5/2018
Page: 1
Permit: WQ0000165 Owner - Facility: Sands Villa Resort HOA Inc DBA Sands Villa Utilities Inc
Inspection Date: 08/13/2018 Inspection Type : Compliance Evaluation Reason for Visit: Complaint
Inspection Summary:
A compliance evaluation (file review and site inspection) was performed by Morella Sanchez King. The purpose of the
evaluation was to verify that the facility is operating in compliance with the conditions and limitations specified in Permit No.
WQ 0000165.
A) File Review (2016-2018)
Effluent parameters: The NDMR file review showed several total nitrogen violations in 2016 and 2017 [October 2016 through
February 2017, in March 2017 (TN=9.31 mg/1), and April 2017 (TN=12.3 mg/I); (2) fecal coliform violations (daily max limit) in
June and August 2017. No BOD or TSS violations in the period.
Groundwater Quality: A review of the GW-59's records indicate sporadic exceedances of the 2L groundwater quality
standards.
• Nitrate- one nitrate exceedance (November 2016: 24.73 mg/1)
• TDS- four TDS exceedances (2 in 2016 and 2 in 2017, slightly above the 2L std of 500 mg/1)
B) Site Inspection
The site inspection was conducted on August 13, 2018. The Division appreciates Mr. Lee Buck for his time and assistance
during the site inspection. The facility looks well maintained and operated. Alarms were functional and effluent was clear
and odorless. Refer to each section of the report for additional comments.
It seems that past problems related with TN and fecal coliform violations have been resolved. The Division appreciates
contacting us (Helen Perez, compliance reviewer- 910 796 7323) for non -compliances issues that the facility could
experience. Also, the Wilmington Regional Office WWTP Wastewater Consultant (Tom Tharrington) can provide support if
operational problems arise.
Page: 2
Permit: WQ0000165
Inspection Date: 08/13/2018
Owner - Facility: Sands Villa Resort HOA Inc DBA Sands Villa Utilities Inc
Inspection Type : Compliance Evaluation Reason for Visit: Complaint
Type
Yes No NA NE
Reuse (Quality)
❑
Single Family Spray, LR
❑
Lagoon Spray, LR
❑
Activated Sludge Spray, HR
❑
Activated Sludge Spray, LR
❑
Recycle/Reuse
❑
Activated Sludge Drip, LR
❑
Single Family Drip
❑
Infiltration System
Treatment Yes No NA NE
Are Treatment facilities consistent with those outlined in the current permit? 0 ❑ ❑ ❑
Do all treatment units appear to be operational? (if no, note below.) 0 ❑ ❑ ❑
Comment: Treatment is provided through a dual train of sequencing batch reactors (SBR). Treatment
cycles are software -controlled. Units seem to be working properly.
Treatment Flow Measurement -Influent
Yes No NA NE
Is flowmeter calibrated annually?
❑
❑
0 ❑
Is flowmeter operating properly?
❑
❑
0 ❑
Does flowmeter monitor continuously?
❑
❑
0 ❑
Does flowmeter record flow?
❑
❑
0 ❑
Does flowmeter appear to monitor accurately?
❑
❑
0 ❑
Comment
Treatment Flow Measurement -Water Use Records Yes No NA NE
Is water use metered? ❑ ❑ 0 ❑
Are the daily average values properly calculated? ❑ ❑ 0 ❑
Comment:
Treatment Flow Measurement -Effluent
Yes No NA NE
Is flowmeter calibrated annually?
0
❑
❑ ❑
Is flowmeter operating properly?
0
❑
❑ ❑
Does flowmeter monitor continuously?
0
❑
❑ ❑
Does flowmeter record flow?
0
❑
❑ ❑
Does flowmeter appear to monitor accurately?
0
❑
❑ ❑
Comment: Flow meter was calibrated 05/11/2018
Treatment Barscreen
Yes No NA NE
Page: 3
Permit: WO0000165
Inspection Date: 08/13/2018
Owner - Facility: Sands Villa Resort HOA Inc DBA Sands Villa Utilities Inc
Inspection Type : Compliance Evaluation Reason for Visit: Complaint
Is it free of excessive debris?
0
❑
❑ ❑
Is disposal of screenings in compliance?
0
❑
❑ ❑
Are the bars spaced properly?
0
❑
❑ ❑
Is the unit in good condition?
0
❑
❑ ❑
Comment
Treatment Activated Sludge
Yes No NA NE
Is the aeration mechanism operable?
0
❑
❑ ❑
Is the aeration basin thoroughly mixed?
0
❑
❑ ❑
Is the aeration equipment easily accessed?
0
❑
❑ ❑
Is Dissolved Oxygen adequate?
❑
❑
❑
Are Settleometer results acceptable?
❑
❑
❑
Is activated sludge an acceptable color?
0
❑
❑ ❑
Comment: At the moment of the inspection, the right
train was reactinq while the left train was in anoxic
mode. Aeration and mixinq look even.
Color was appropriate.
Treatment Filters
Yes No NA NE
Is the filter media present?
❑
❑
❑
Is the filter media the correct size and type?
❑
❑
❑
Is the air scour operational?
❑
❑ ❑
Is the scouring acceptable?
❑
❑
❑
Is the clear well free of excessive solids?
0
❑
❑ ❑
Is the mud well free of excessive solids and filter media?
0
❑
❑ ❑
Does backwashing frequency appear adequate?
0
❑
❑ ❑
Comment: Backwashing is performed automatically,
according to the flow and cycle duration. Therefore, it
was not possible to observe air scouring
and filter backwash at the moment of the inspection.
The ORC indicated that the filters are working properly.
Treatment Disinfection
Yes No NA NE
Is the system working?
0
❑
❑ ❑
Do the fecal coliform results indicate proper disinfection?
0
❑
❑ ❑
Is there adequate detention time (-30 minutes)?
❑
❑
❑
Is the system properly maintained?
❑
❑ ❑
If gas, does the cylinder storage appear safe?
❑
❑
0 ❑
Is the fan in the chlorine feed room and storage area operable?
❑
❑
0 ❑
Is the chlorinator accessible?
❑
❑
0 ❑
If tablets, are tablets present?
❑
❑
0 ❑
Are the tablets the proper size and type?
❑
❑
❑
Is contact chamber free of sludge, solids, and growth?
❑
❑ ❑
Page: 4
Permit: WO0000165 Owner - Facility: Sands Villa Resort HOA Inc DBA Sands Villa Utilities Inc
Inspection Date: 08/13/2018 Inspection Type : Compliance Evaluation Reason for Visit: Complaint
If UV, are extra UV bulbs available?
0
❑
❑ ❑
If UV, is the UV intensity adequate?
❑
❑
❑
# Is it a dual feed system?
0
❑
❑ ❑
Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)?
❑
❑
0 ❑
If yes, then is there a Risk Management Plan on site?
❑
❑ ❑
If yes, then what is the EPA twelve digit ID Number? (1000-_ _)
If yes, then when was the RMP last updated?
Comment: NDMR records showed fecal coliform violations (daily max limit) in June and August 2017.
No
violations have been reported in 2018.
Record Keeping
Yes No NA NE
Is a copy of current permit available?
❑
❑ ❑
Are monitoring reports present: NDMR?
❑
❑ ❑
NDAR?
❑
❑ ❑
Are flow rates less than of permitted flow?
❑
❑ ❑
Are flow rates less than of permitted flow?
❑
❑ ❑
Are application rates adhered to?
❑
❑ ❑
Is GW monitoring being conducted, if required (GW-59s submitted)?
❑
❑ ❑
Are all samples analyzed for all required parameters?
❑
❑ ❑
Are there any 2L GW quality violations?
❑
❑ ❑
Is GW-59A certification form completed for facility?
❑
❑ ❑
Is effluent sampled for same parameters as GW?
❑
❑ ❑
Do effluent concentrations exceed GW standards?
❑
❑ ❑
Are annual soil reports available?
❑
❑
0 ❑
# Are PAN records required?
❑
❑
0 ❑
# Did last soil report indicate a need for lime?
❑
❑
❑
If so, has it been applied?
❑
❑ ❑
Are operational logs present?
❑
❑ ❑
Are lab sheets available for review?
❑
❑ ❑
Do lab sheets support data reported on NDMR?
❑
❑ ❑
Do lab sheets support data reported on GW-59s?
❑
❑ ❑
Are Operational and Maintenance records present?
❑
❑
❑
Were Operational and Maintenance records complete?
❑
❑
❑
Has permittee been free of public complaints in last 12 months?
0
❑
❑ ❑
Is a copy of the SOC readily available?
❑
❑
0 ❑
No treatment units bypassed since last inspection?
❑
0
❑ ❑
Page: 5
Permit: WO0000165 Owner - Facility: Sands Villa Resort HOA Inc DBA Sands Villa Utilities Inc
Inspection Date: 08/13/2018 Inspection Type : Compliance Evaluation Reason for Visit: Complaint
Comment: A review of the GW-59's records indicate sporadic exceedances of the 2L groundwater quality
standards.
_ Nitrate- one nitrate exceedance (November 2016: 24.73 mg/1)
TDS- four TDS exceedances (2 in 2016 and 2 in 2017, slightly above the 2L std of 500 mg/1)
End Use -Infiltration Yes No NA NE
# Is the application High Rate or Low Rate? High Rate
Are buffers maintained?
❑
❑
❑
Are any supply wells within the CB?
❑
0
❑ ❑
Are any supply wells within 250' of the CB?
❑
0
❑ ❑
Is municipal water available in the area?
0
❑
❑ ❑
Are GW monitoring wells required?
0
❑
❑ ❑
Are GW monitoring wells located properly w/ respect to RB and CB?
❑
❑
❑
Are GW monitoring wells properly constructed, including screened interval?
❑
❑
❑
Is a usable green area maintained?
0
❑
❑ ❑
Is the disposal site acceptable?
❑
❑ ❑
Is the distribution equipment acceptable?
❑
❑ ❑
Is the disposal site free of ponding?
❑
❑ ❑
Is the disposal site free of breakout?
0
❑
❑ ❑
Are the disposal sites free of solids, algae, etc.?
0
❑
❑ ❑
Do the records show that the fields are properly maintained?
0
❑
❑ ❑
Are the disposal sites free of vegetation?
❑
0
❑ ❑
Do any surface water features appear to be adversely impacted by GW discharge?
❑
0
❑ ❑
No chemicals or rototiller used to eliminate vegetation, solids, algae, etc.?
M
❑
❑ ❑
Comment: In the permit issued on May 13, 2016 the condition regardinq no vegetation in the H-R fields was
removed as requested by the permittee and supported by the WiRO. Well kept vegetation
is
allowed in H/R infiltration fields as long as it does not affect the infiltration capacity
of the areas.
Page: 6