HomeMy WebLinkAboutNC0023191_Inspection_20181102NORTH CAROL NA ROY COOPER Errvrranrh#1t1G1 QUdlfly G&V 01tw MICHAEL S. REGAL Secr�rary LfNDA CULPEPPER In redm D,'rsctor 2 November 2018 Mr. David Millsaps, Owner Seven Cedars MHP Post Office Box 1143 Statesville, North Carolina 28687 Subject: Compliance Sampling Inspection Seven Cedars MHP WWTP NPDES Permit No. NCO023191 Iredell County Dear Mr. Millsaps: Enclosed is a copy of the Compliance Evaluation Inspection Report for the inspection conducted at the subject facility on October 25, 2018, by Mr. Wes Bell of this Office. Please inform the facility's Operator -in -Responsible Charge (ORC) of our findings by forwarding a copy of the enclosed report. The results of the effluent samples collected during the inspection will be forwarded to you under separate cover. Should you have any questions concerning this letter, please do not hesitate to contact Mr. Bell at (704) 235-2192, or via email at wes.bell@ncdenr.gov. Enclosure: Inspection Report Sincerely, DocuSigned by: F161 FB69A2D84A3... For W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ EQ.:> "-mr North Carolina Department of Environmental Quality I Division of Water Resources 610 East Center Avenue I Suite 301 I Mooresville, North Carolina 28115 704.663.1699 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 15 I 3 I NC0023191 111 12 I 18/10/25 I17 18 i � i 19 i G i 201 I 211111 I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I f6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 2.0 70 71 [.. I 72 73 L_LJ74 751 I I I I I I I80 u u Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES oermit Number) 12:40PM 18/10/25 14/06/01 Seven Cedars Mobile Home Park WWTP Village Dr Exit Time/Date Permit Expiration Date Statesville NC 28677 02:OOPM 18/10/25 19/03/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Todd Franklin Robinson/ORC/704-881-4598/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted David Lynn Millsaps,PO Box 1143 Statesville NC 28687/Owner/704-902-9521/7048725515 Yes Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date EDocusigned by: 11/1/2018 Wes Bell �� � MRO WQ//704-663-1699 Ext.2192/ A61696D90CC3437... Signature of Man 8ff6 9vwer Agency/Office/Phone and Fax Numbers Date CA*,t"11/2/18 H PRO Andrew WQ//704-663-1699 Ext.21 1`161 FB69AMUA3... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type NC0023191 I11 121 18/10/25 117 18 ISI Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On -site Representatives: The following Envirolink, Inc. personnel were in attendance during the inspection: Mr. Chris Bitterman, Mr. Chip White, Mr. Todd Robinson, and Mr. Dennis Murdock. Page# Permit: NCO023191 Owner - Facility: Seven Cedars Mobile Home Park WWTP Inspection Date: 10/25/2018 Inspection Type: Compliance Sampling Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new 0 ❑ ❑ ❑ application? Is the facility as described in the permit? 0 ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ ❑ 0 ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: The Division received the permit renewal documentation on 9/11/18. The last compliance evaluation inspection was performed at the facility on 8/8/17 by DWR staff. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? 0 ❑ ❑ ❑ Is all required information readily available, complete and current? 0 ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? 0 ❑ ❑ ❑ Is the chain -of -custody complete? 0 ❑ ❑ ❑ Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ ❑ on each shift? Is the ORC visitation log available and current? ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ❑ ❑ ❑ Page# 3 Permit: NCO023191 Inspection Date: 10/25/2018 Record Keeping Owner - Facility: Seven Cedars Mobile Home Park WWTP Inspection Type: Compliance Sampling Yes No NA NE Comment: The records reviewed durina the inspection were oraanized and well maintained. Discharae Monitoring Reports (eDMRs) were reviewed for the period September 2017 through August 2018. Daily maximum effluent BOD and TSS violations were reported in February 2018. Only one effluent ammonia sample (twice per month required) was collected and reported in January 2018 and August 2018. The Division has previously addressed these limit and monitoring violations through the issuances of either a NOV or civil penalty assessment. The 10-day interval between the collection of the twice per month effluent ammonia samples was not adhered to in March 2018. The ORC and staff will amend the August 2018 eDMR to accurately reflect the facility visitations (five days per week instead of three). Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? 0 ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? 0 ❑ ❑ ❑ # Is the facility using a contract lab? 0 ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ 0 ❑ Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? ❑ ❑ 0 ❑ Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? ❑ ❑ 0 ❑ Comment: On -site field analvses (DH and temperature) are performed under Envirolink. Inc.'s field laboratory certification #5212. Statesville Analytical, Inc. (Certification #440) has also been contracted to provide analytical support for all remaining permit -required parameters (BOD, TSS, ammonia, total nitrogen, total phosphorus). The ORC and staff must ensure to perform post -analysis calibration checks on the pH meter following field analyses at multiple sites. Post -analysis calibration checks must be performed in accordance with the NC Wastewater/Groundwater laboratory certification approved procedures for the analyses of PH. Note: Post analysis checks would also be required for dissolved oxygen and total residual chlorine meters if applicable. Effluent Sampling Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Comment: The subject permit requires effluent grab samples. Operations & Maintenance Yes No NA NE ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ Yes No NA NE Page# 4 Permit: NCO023191 Owner - Facility: Seven Cedars Mobile Home Park WWTP Inspection Date: 10/25/2018 Inspection Type: Compliance Sampling Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: The wastewater treatment facility appeared to be properly operated and well maintained. Bar Screens Yes No NA NE Type of bar screen a.Manual b.Mechanical ❑ Are the bars adequately screening debris? 0 ❑ ❑ ❑ Is the screen free of excessive debris? 0 ❑ ❑ ❑ Is disposal of screening in compliance? 0 ❑ ❑ ❑ Is the unit in good condition? 0 ❑ ❑ ❑ Comment: Screenings are disposed at a permitted landfill. Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? 0 ❑ ❑ ❑ Are surface aerators and mixers operational? ❑ ❑ 0 ❑ Are the diffusers operational? 0 ❑ ❑ ❑ Is the foam the proper color for the treatment process? 0 ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? ❑ ❑ 0 ❑ Is the DO level acceptable? 0 ❑ ❑ ❑ Is the DO level acceptable?(1.0 to 3.0 mg/1) ❑ ❑ 0 ❑ Comment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? 0 ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? 0 ❑ ❑ ❑ Are weirs level? 0 ❑ ❑ ❑ Is the site free of weir blockage? 0 ❑ ❑ ❑ Is the site free of evidence of short-circuiting? 0 ❑ ❑ ❑ Is scum removal adequate? 0 ❑ ❑ ❑ Page# 5 Permit: NCO023191 Inspection Date: 10/25/2018 Secondary Clarifier Is the site free of excessive floating sludge? Is the drive unit operational? Owner - Facility: Seven Cedars Mobile Home Park WWTP Inspection Type: Compliance Sampling Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) Comment: Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Yes No NA NE ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ Comment: Instantaneous flow measurements are performed by the bucket and stop watch method. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment: The effluent aDDeared sliahtiv turbid with no floatable solids or foam. The effluent dissolved oxygen, PH, and temperature were measured (during the inspection) at 7.82 mg/L (DO), 7.74 SU (PH), and 14.4 degrees Celsius (temperature). In addition, DWR staff collected effluent BOD, TSS, ammonia, fecal coliform, total nitrogen and total phosphorus samples during the inspection. The results of these effluent samples will be forwarded under separate cover. Aerobic Digester Yes No NA NE Is the capacity adequate? 0 ❑ ❑ ❑ Is the mixing adequate? 0 ❑ ❑ ❑ Is the site free of excessive foaming in the tank? 0 ❑ ❑ ❑ # Is the odor acceptable? 0 ❑ ❑ ❑ # Is tankage available for properly waste sludge? 0 ❑ ❑ ❑ Comment: Wastewater solids from the aerated sludge holding tanks are removed on an as -needed basis by a contracted company (L&L Environmental). Page# 6 AC56810 North Carolina Division of Water Resources Water Sciences Section Laboratory Results Loc. Descr.: SEVEN CEDARS MHP WWTP County: Iredell Collector: W BELL VisitlD Region: Mooresville Report To MRO Location ID: NCO023191 River Basin YADKIN PEE DEE Collect Date: 10/2912018 Priority COMPLIANCE/COC Emergency Collect Time: 12_50 Sample Matrix: WASTEWATER COC Yes/No YES Sample Depth Loc. Type: Effluent Final Report Sample ID: AC56810 PO Number # Date Received: 1012612018 Time Received: 08:10 Labworks LoginlD TASCENZ01 Delivery Method NC Courier Final Report Date: 11/1411 B Report Print Date: 1111612018 If this report is labeled preliminary report, the results have not been validated. Do not use for Regulatory purposes. Result) Method Analysis Units CAS # Analyte Name PQL Qualifier Reference Date Validated by LAB Sample temperature at receipt by lab 1.1 aC 10/26/18 MSWIFT MIC BOD, 5-Day in liquid 2.0 4.2 mg1L SM 5210 B-2001 10/26/18 ESTAFFORDi Coliform, MF Fecal in liquid 1 1600 B5,01 CFU1100ml SM 9222 D-1997 10/26/10 ESTAFFORDI NUT NH3 as N in liquid 0.02 0.02 U mg1L as N EPA 350.1 REV 2 10/31/18 CGREEN NO2+NO3 as N in liquid 0.02 33 mg1L as N EPA 353.2 REV 2 10131/18 CGREEN Phosphorus —total as P in liquid 0.02 4.9 mg1L as P EPA 365.1 REV 2 1112118 CGREEN Total Kjeldahl N as N in liquid 0.2 1.9 mg1L as N EPA 351.2 REV 2 1119118 CGREEN WET Residue —Suspended in liquid 6.2 12 mg/L SM 2540 D-1997 10131118 CGREEN WSS Chemistry Laboratory» 1623 Mail Service Center, Raleigh, NO 27699-1623 (919) 733-3908 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. Page 1 of 3 NC rD'MAK La6oratory Section (�sufts/Sarnpf- Comrnents/Quafifier (Definitions Sample ID: ACS6810 Result/ Method Analysis ualifier Units Reference Date validated by Sample Comments MIC:Fecal Coliform-e5-Too Numerous To Count. MIC:Fecal Coliform-Q 1-Sample exceeded holding time prior to receipt at lab. NCDEQ-WSS-Chemistry Lab Data Qualifiers Al The reported value is an average, where at least one result is qualified with a "U". The PQL is used for the qualified result(S) to call B1 Coliform-Countable membranes with less than 20 colonies. Reported value is estimated or is a total of the counts on all filters repor B2 Coliform-Counts from all filters were zero. The value reported is based on the number of colonies per 100 ml that would have been 83 Coliform-Countable membranes with more than 60 or 80 colonies. The value reported is calculated using the count from the smalle B4 Coliform-Filters have counts of both >60 or 80 and <20. Reported value is estimated or is a total of the counts on all filters reported B5 Coliform-Too many colonies were present; too numerous to count (TNTC). TNTC is generally defined as >150 colonies. B6 Coliform-Estimated Value. Blank contamination evident. B7 Coliform-Many non-coliform or non-enterococcus colonies or interfering non-coliform or non-enterococcus growth present. In this cc BB1 MPN-No wells or tubes gave a positive reaction. Value based upon the appropriate MPN Index and reported as a less than "<" valu BB2 MPN-AII wells or tubes gave positive reactions. Value based upon the MPN Index and reported as a greater than ">" value. C Total residual chlorine was present in sample upon receipt in the laboratory; value is estimated. G1 BOD-The dissolved oxygen (DO) depletion of the dilution water blank exceeded 0.2 mg/L. G2 BOD-The bacterial seed controls did not meet the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at lea: G3 BOD-No sample dilution met the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at least 1.0 mg/L. G4 BOD-Evidence of toxicity. This is generally characterized by a significant increase in the BOO value as the sample concentration de G5 BOD-The glucose/ glutamic acid standard exceeded the range of 198 ± 30.5 mg/L. G6 BOD-The calculated seed correction exceeded the range of 0.6 to 1.0 mg/L. G7 BOD-Less than 1 mg/L DO remained for all dilutions set. The reported value is an estimated greater than value and is calculated fo G8 BOD-Oxygen usage is less than 2 mg/L for all dilutions set. The reported value is an estimated less than value and is calculated for G9 BOD-The DO depletion of the dilution water blank produced a negative value. it Surrogate recovery limits have been exceeded. J2 The reported value failed to meet the established quality control criteria for either precision or accuracy. WSS Chemistry Laboratory>> 1623 Mail Service Center, Raleigh, NC 27699.1623 (919) 733-3908 "Not Detected" or "U" does not indicate the sample is anayte free but that the analyte is not detected at or above the PQL. Page 2 of 3 NC (D`A Laboratory Section 9?Ssurta/Sample Comments/Quarifi'er (Definitions Sample ID: AC66810 Result/ Method Analysis uuallrler Unns Lelereliw Uale J3 The sample matrix interfered with the ability to make any accurate determination. J4 The data is questionable because of improper laboratory or field protocols (e.g., composite sample was collected instead of grab, p J5 Temperature limits exceeded (samples frozen or >6°C) during transport or not verifiable (e.g., no temperature blank provided): non- J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. J7 This qualifier is used to identify analyte concentration exceeding the upper calibration range of the analytical instrument/method. Th J8 Temperature limits exceeded (samples frozen or>60C) during storage, the data may not be accurate. J9 The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration J10 Unidentified peak: estimated value. J11 The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration J12 The calibration verification did not meet the calibration acceptance criterion for field parameters. M Sample and duplicate results are "out of control'. The sample is non -homogenous (e.g., VOA soil). The reported value is the lower, N1 Presumptive evidence and estimated value. The component has been tentatively identified base on mass spectral library. N2 There is an indication that the analyte is present, but quality control requirements for confirmation were not met (i.e., presence of e N3 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo N4 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo N5 The component has been tentatively identified based on a retention time standard. Q1 Holding time exceeded prior to receipt by lab. Q2 Holding time exceeded following receipt by lab. P Elevated PQL` due to matrix interference and/or sample dilution. S Not enough sample provided to prepare and/or analyze a method -required matrix spike (MS) and/or matrix spike duplicate (MSD). U Indicates that the analyte was analyzed for but not detected above the reported practical quantitation limit'. The number value repo X1 Sample not screened for this compound. X2 Sampled, but analysis lost or not performed -field error. X3 Sampled, but analysis lost or not performed -lab error.- - - - - - - -- - V Indicates the analyte was detected in both the sample and the associated method blank. Note: The value in the blank shall not be s Y Elevated PQL` due to insufficient sample size. Z1 Inability to analyze the sample. Z2 Questions concerning data reliability. U, J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. UU Indicates that the analyte was not detected by a screen analysis. The number value was determined by a one -point estimation at tt WSS Chemistry Laboratory>> 1623 Mall Service Center, Raleigh, NC 27699.1623 (919) 7334908 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. Page 3 of 3 NORTH CAROL NA ROY COOPER Envrranrh#1t1G1 QUdlfly G&V0 tw MICHAEL S. RE AN Secr�rary LfNDA CULPEPPER In redm D,'rsctor 20 November 2018 Mr. David Millsaps, Owner Seven Cedars MHP Post Office Box 1143 Statesville, North Carolina 28687 Subject: Effluent Sampling Results Seven Cedars MHP WWTP NPDES Permit No. NCO023191 Iredell County Dear Mr. Millsaps: Enclosed is a copy of the laboratory results for the effluent samples collected during the Compliance Sampling Inspection performed at the subject facility on October 25, 2018, by Mr. Wes Bell of this Office. Effluent grab samples were collected at Outfall 001 during this inspection. The facility complied with all applicable permit limits (daily maximums). Please attach this correspondence with the previously issued inspection report (dated November 2, 2018) to complete your records. Should you have any questions concerning this letter, please do not hesitate to contact Mr. Bell at (704) 235-2192, or via email at wes.bell@ncdenr.gov. Enclosure: Effluent Results Sincerely, DocuSigned by: A14CC681AF27425... W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ EQ.:> "-mr North Carolina Department of Environmental Quality I Division of Water Resources 610 East Center Avenue I Suite 301I Mooresville, North Carolina 28115 704.663.1699