Loading...
HomeMy WebLinkAboutWQ0000484_Permit Correction_20181102NORTH CAROLINA Ploy COOPER Ehvii onwental Qual r Coves III H ,EL S. REEit seemlary LINDA CULPEPPER kreffm November 2, 2018 NOLAN TRENT REYNOLDS — DIRECTOR OF PROCESSING OPERATIONS MOUNTAIRE FARMS INC. POST OFFICE BOX 1320 MILLSBORO, DELAWARE 19966 Subject: Permit No. WQ0000484 Correction Mountaire Farms — Lumber Bridge WWTF Wastewater Irrigation System Robeson County Dear Mr. Reynolds: In accordance with a written request received October 4, 2018 from Austin Pajda, we are forwarding herewith a corrected Attachment A of Permit No. WQ0000484 issued October 1, 2018. The correction to the subject permit is as follows: 1. Footnote #2 for PPI 001, and the footnote for PPI 002 have been removed. Please replace Attachment A of Permit No. WQ0000484 issued October 1, 2018 with the enclosed corrected Attachment A. If you need additional information concerning this permit correction, please contact Tessa Monday at (919) 707-3660 or tessa.monday9.ncd( Sincerely, ?'-Linda Culpepper, Interim Director -Linda of Water Resources Enclosure cc: Robeson County Health Department (Electronic Copy) Fayetteville Regional Office, Water Quality Regional Operations Section (Electronic Copy) Laserfiche File (Electronic Copy) Digital Permit Archive (Electronic Copy) Central Files �D IEQ� wl=�"\ - 'aw* North Carolina Department of Environmental Quality I Division of Water Resources I Non -Discharge Branch 512 North Salisbury Street 11617 Mail Service Center I Raleigh, North Carolina 27699-1617 919.707.3653 ATTACHMENT A — LIMITATIONS AND MONITORING REQUIREMENTS Permit Number: WQ0000484 Version: 4.1 PPI 001— Storage Lagoon Effluent EFFLUENT CHARACTERISTICS EFFLUENT LIMITS MONITORING REQUIREMENTS Measurement Sample Frequency Type PCs Code Parameter Description Units of Measure Monthly Average Monthly Geometric Mean Daily Minimum Daily Maximum 00310 BOD, 5-Day (20 °C) mg/L 2 x Week Grab 01027 Cadmium, Total (as Cd) mg/L Monthly Grab 00916 Calcium, Total (as Ca) mg/L Monthly Grab 00940 Chloride (as Cl) mg/L 3 x Year Grab 50060 Chlorine, Total Residual mg/L 5 x Week Grab 31616 Coliform, Fecal MF, M-FC Broth, 44.5 °C #/100 mL 2 x Month Grab 01042 Copper, Total (as Cu) mg/L Monthly Grab 50050 Flow, in Conduit or thru Treatment Plant GPD 2,550,000 Continuous Recorder 01051 Lead, Total (as Pb) mg/L Monthly Grab 00927 Magnesium, Total (as Mg) mg/L Monthly Grab 01067 Nickel, Total (as N) mg/L Monthly Grab 00610 Nitrogen, Ammonia Total (as N) mg/L 2 x Month Grab 00625 Nitrogen, Kjeldahl, Total (as N) mg/L 2 x Month Grab 00620 Nitrogen, Nitrate Total (as N) mg/L 2 x Month Grab 00600 Nitrogen, Total (as N) mg/L 2 x Month Grab 00400 pH su 5 x Week Grab 00665 Phosphorus, Total (as P) mg/L 2 x Month Grab WQ09C Plant Available Nitrogen - Concentration mg/L 2 x Month Grab 00931 Sodium Absorption Ratio ratio Monthly Grab 00929 Sodium, Total (as Na) mg/L Monthly Grab 70300 Solids, Total Dissolved —180 °C mg/L 3 x Year Grab 00530 Solids, Total Suspended mg/L 2 x Month Grab 01092 Zinc, Total (as Zn) mg/L Monthly Grab 3 x Year sampling shall be conducted during April, August, and December. WQ0000484 Version 4.1 Attachment A Page 1 of 1 PPI 002 — Industrial WWTP Effluent EFFLUENT CHARACTERISTICS EFFLUENT LIMITS i MONITORING REQUIREMENTS PCs Parameter Description Units of Monthly Monthly Daily Minimum I Daily Maximum Measurement Sample Code Measure Average Geometric Mean Frequency Type 50050 Flow, in Conduit or thru Treatment Plant GPD 2,550,000 Continuous Recorder PPI 003 — Domestic WWTP Effluent EFFLUENT CHARACTERISTICS EFFLUENT LIMITS MONITORING REQUIREMENTS PCs Code Parameter Description Units of Measure Monthly Average Monthly Geometric Mean Daily Minimum Daily Maximum Measurement Frequency Sample Type 50050 Flow, in Conduit or thru Treatment Plant GPD 40,000 Continuous Recorder PPI 004 — Surface Water Monitoring Station SW-1 (34.872584°,-79.116861°) EFFLUENT CHARACTERISTICS EFFLUENT LIMITS MONITORING REQUIREMENTS PCs Units of Monthly Monthly Measurement Sample Code Parameter Description Measure Average Geometric Mean Daily Minimum Daily Maximum Frequency Type 00620 Nitrogen, Nitrate Total (as N) mg/L Monthly Grab PPI 005 — Groundwater Lowering System Effluent EFFLUENT CHARACTERISTICS EFFLUENT LIMITS MONITORING REQUIREMENTS PCs Parameter Description Units of Monthly Monthly Daily Minimum Daily Maximum Measurement Sample Code Measure Average Geometric Mean Frequency Type 50050 Flow, in Conduit or thru Treatment Plant GPD Continuous Recorder WQ0000484 Version 4.1 Attachment A Page 2 of 2 :z -3 198A 200 MW-34 20 12L 198 196 M-33 V WNF36 it —09849 [192 ba I - ,Iv V.32 -3JJ 186 I IRS 95) 7 -2 24 20 197 _SY affs. lrv.- I qW-29 V 19126 m m 1mw-IS -093.79 F. l MW-26 �14,W-18 X L199 MW-52 118L6 I �1 6, m m 27J LV MW4 B 180 76 W4 Jm --B-- - -14 194 �91.66 le 198 196 1911 _11921 MW4D s—F.W JMW-20 MI 8 5.115 mw-19 LL9-1. (18419); '(189AD);\ 1161 /x mw-III rMW -.6 -120035 Jz1i 194 Q ISE 194 51Y % .96 Legend Boundary of Subject Site Boundary of Tax Parcel 1 99 1 Boundary offirrigation Field MW43 Irrigation Field Compliance Boundary t�9927% Irrigation Field Review Boundary Proposed Review/Compliance Boundary w Adjusted, Prior Review Boundarv, Boundary of Water Bodies I N Buried Natural Gas Line -A--A, overhead Powerlines H+H+Hi+ Railroad Tracks 0 Existing Monitoring Wells 0 Monitoring Wells Abandoned in June 2018 Polentiornetric Surface Contour (dashed nhere inferred) (194.54) Groundwater Elevation in Feet (mml) Potentiometric Surface Elevation for August 18, 2018 1:>DUNCKLEE & DUNHAM Momtaire Farms ofNorth Carolina LmberBrid e North Colina 511 Checked By: Project Number. Date: : So, .....By: �31� 2017145 September1=500- I'e:2" 34" Layers: 12 16,22-2 Ce,,.X.MC..0.27501. . NCE,EAI—NaC-3159 NC G,.. U—. N.. 6261